CreekSide XVI & XVIII...CreekSide XVI & XVIII Overview Location 2353 & 2373 Global Drive Lockbourne,...
Transcript of CreekSide XVI & XVIII...CreekSide XVI & XVIII Overview Location 2353 & 2373 Global Drive Lockbourne,...
CreekSide XVI & XVIII
Development / Management / Consulting / Construction / Leasing
Table of Contents
Table of Contents
Tab 1 Project Overview
Tab 2 Site Plan & Aerial
Project Overview 1
Development / Management / Consulting / Construction / Leasing
Project Overview
CreekSide XVI & XVIII Overview
Location2353 & 2373 Global Drive Lockbourne, OH 43125
EconomicsAsking Rate• $4.50-$4.75 PSF
Operating Expenses• $0.50 PSF
Leasing ContactThe Pizzuti CompaniesPhil Rasey614/280-4008 (P)614/280-5000 (F)[email protected]
Building Dimensions• CreekSide XVI - 155,866 square feet• CreekSide XVIII - 236,140 square feet• 32’ clear height• 50’ x 54’ column spacing and 60’ speed bay
CreekSide Advantage• Industrial and Distribution Center 500-acre master-planned park ideal
for distribution and light manufacturing• Strategically Located within 500 miles of 60% of North America’s
population• Norfolk-Southern Intermodal - Conveniently located within 3 miles of
new Norfolk-Southern Intermodal facility; within 1 mile of Alum Creek andI-270, minutes from I-70 and I-71
• Industrial Distribution Corridor features multiple transportation options,including highway, air, rail and major delivery systems; just minutes fromPort Columbus International Airport and Rickenbacker Air Industrial Park
• Unparalled Tax Incentives 15-year, 100 percent real estate taxabatement
• Utility Savings zone provides electricity and natural gas designed tocapturetobenefitsofcompetition;lowerprices,betterserviceandnewerproducts;Municipalutilityofferssavingsovercompetingrates
Development / Management / Consulting / Construction / Leasing
Project Overview
HVAC•Warehouseheatedbygas-forcedair rotation units•Systemwillmaintain60ºFat0ºFoutside Concrete Work•Floorisa7”slabinwarehouseareaandtrafficlanes•Dowelledconstructionjointsandsawcut control joints•Concretefloorswithaminimum compressive strength of 4,000 psi•FloorflatnessminimumofFf45pertheacceptableFaceflatness standards
Dock Layout•60’concreteapronindockarea•28dockopeningsequippedwith9’x10’ insulated sectional steel overhead doors,pits,40,000lb.9’x10’levelers,sheltersand bumpers with provisions for additional doors•Four14’x16’drive-throughdoors
Lighting•Twohighbay LEDlights perbay with motion sensors
Plumbing•2”domesticwater service main•8”firemainwith6” sprinkler laterals
Electrical•Three600AMP,277/480volt 3-phase service located on the dock side of building•Additionalpoweravailableasneededvia four transformer locations
Roof•WhiteTPOroofwith10-yearwarranty
Insulation Values•Walls=R10•Roof=R20
Fire Protection•ESFRSprinklersystem•8”firelooparoundbuildingwithhydrants
creekside
Port ColumbusInternational
Airport
DowntownColumbus
315
104
270
70
70
71
71
670
23
33AlumCreekDrive
Rickenbacker Airport
Site Plan & Aerial 2
Cree
kSide
XVI
& X
VIII
Dev
elop
men
t / M
anag
emen
t / C
onsu
lting
/ C
onst
ruct
ion
/ Lea
sing
Cree
kSide
XVI
& X
VIII
Dev
elop
men
t / M
anag
emen
t / C
onsu
lting
/ C
onst
ruct
ion
/ Lea
sing
CreekSide Industrial Center
�� �� �� � � � � � � �� � � � � � � � � � � � � � � � � � � �� � � � �� � �� � � � � �