Create Airofmultimedia.3m.com/mws/media/938672O/3m-air-management-products-for...Create an Air of....
Transcript of Create Airofmultimedia.3m.com/mws/media/938672O/3m-air-management-products-for...Create an Air of....
3M Purification Inc.3M™ Air Management Products for Your Commercial HVAC Needs
Confidence
CreateAiran of
Pursuing Innovation3M Company has long encouraged employees to pursue ideas and
concepts that might, at first, seem unusual or odd to some people.
From those efforts, many innovations were born.
In the late 1930s, one of 3M’s scientists Al Boese began a journey to
develop an inexpensive, noncorrosive backing that was fibrous, but not
woven, for electrical tape. The journey took him through a decade of
learning and experimentation that did not produce a better backing for
electrical tape, but did lead to an amazing series of products using the
new technology. Al Boese retired in the 1980s, however, the journey
he started continues today: 3M is still finding new ways to refine and
apply the nonwoven materials.
Making the ConnectionOne of the most successful uses of the 3M non-woven technology
is the 3M personal respirator. The challenge for the product design
is to protect individuals, while also allowing maximum comfort and
breathability. The innovation required to do this was years of R&D
research, resulting in a fundamental base for 3M HVAC air filters.
It was the same principle, stop unwanted particles but maximizing
airflow.
“Breathable” FiltrationToday, 3M is arguably considered the world’s leading
expert on “breathable” synthetic-based filtration
products. For 3M HVAC air filters, this means
filtration with best in class pressure drops and
lightweight media, analogous to the design criteria
for personal respirators.
Technological Innovation Journey
First 3M™ Nonwoven Products
Introduced
1940s
Meltblown Webs
1950s
HVAC V-Bank Filters
2010s
First HVAC Mini-pleated
Filters
2000s
Cabin Air Filters
1990s
Furnace Filters
1980s
Surgical Masks
1970s
Personal Respirators
1960s
Building managers and HVAC engineers often face a fine balance of finding the best air filter solution
for the building and keeping their operating budgets in check. Meeting environmental requirements for
buildings is becoming increasingly important too.
Energy consumption related to HVAC systems is a significant component of the overall energy
consumption required to operate a building. Using energy efficient air handlers is one step towards
reducing those operational costs. Choosing the right HVAC replacement filters helps maximize those
savings opportunities.
The greater the ability of a filter to load with debris without substantial increase in pressure drop, the
greater the possible energy savings. HVAC engineers typically look for filters that have a low initial
pressure drop, high filter loading capacity and the minimum required particle capture efficiency
required.
Filtration requirements, time constraints, energy, and sustainability efforts create a number
of decisions that have to be researched and analyzed. Using HVAC filter and air handling unit
performance data, 3M can help managers look for opportunities for improvement in associated Total
Cost of Ownership (TCO).
Focusing on opportunities to lower energy consumption, reduce filter maintenance time and reduce
waste stream volume, have provided favorable results.
Our Story
Technological Innovation Journey
Total Cost of Ownership
There are five components of the
ownership and operating cost of HVAC
filters: the cost to purchase the filters,
the cost of the associated energy use,
the cost of labor for installation and
replacement, the cost of disposal,
and the cost of shipping. Using 3M™
Commercial HVAC Filters may have a
positive impact on the ownership and
operating cost as a result of their low
pressure drop and their design for long
filter life. The Total Cost of Ownership
tool from 3M, for commercial HVAC
air filtration systems, can be utilized to
compare 3M Commercial HVAC Filters
with alternative filter options. 3M offers
complimentary filter evaluation services
to help in your decision-making.
V-Bank Filters
MERV A15MERV A14
MERV A13
3M™ Commercial HVAC V-Bank Filters MERV A13, MERV A14 and MERV A15 offer a unique combination of performance and design features including integral gaskets and nested pleat packs. These filters are an excellent choice for building owners and facility managers looking to reduce their energy utiliza-tion and minimize their total cost of operation, while still providing building occupants with high quality filtered air.
Using 3M technologies, these commercial HVAC filters offer an industry leading combination of low pressure drop, robust efficiency, longevity, low weight as well as unique design features. These design features include nested pleats for reduced pressure drop and highly engineered media with a precise balance of mechanical and electret characteristics. The robust efficiency of these filters is tested to the rigorous industry filter conditioning standard – ASHRAE 52.2: 2007 Appendix J.
3M™ V-Bank Filters are the only HVAC V-Bank filters that feature innovative integral gaskets. No other manufacturer offers this feature, which helps prevent unfiltered air from flowing past gaps between the filter and the filter rack. The integral gaskets from 3M are factory installed, which not only save time during installation, but ensure that gaskets will be used.
Key benefits
�� Potential for reduction in electrical energy consumption due to industry leading low initial pressure drop.
�� Filters with MERV 13 and greater ratings contribute to earning a point in the LEED certification process for new and existing buildings when used on all outside air intakes and inside air recirculation returns.
�� Filters with MERV A13 and A14 ratings meet the Facilities Guidelines Institutes (ANSI / ASHRAE / ASHE Standard 170 - 2013) requirements for hospitals and healthcare facilities where MERV 13 or 14 primary filters are required.
�� Long filter life, due to the unique combination of electret, depth-loading filtration media, the precision pleat structure and high filter media area.
�� Factory installed gaskets ensure correct installation and usage, resulting in consistent reduction of air bypass, as well as eliminating the need for additional labor to install gaskets on-site.
�� Due to their lightweight frame construction, 3M™ V-Bank Filters are easier to handle, transport, and install than many comparable V-Bank filters and metal box filters. Lighter weight is especially important when HVAC filters must be manually carried to the air handler.
�� 3M V-Bank Filters are 100% synthetic, resulting in moisture and humidity resistant, corrosion free filters that do not support mold growth.
�� 3M V-Bank Filters are 100% metal free and fully incinerable.
�� 3M V-Bank Filters meet UL 900 flammability rating (US) and UL 900 Class 2 flammability rating (Canada).
�� Reverse Flow options are also available.
■■ Industry leading low pressure drop
■■ Long filter life
■■ Factory installed gaskets for consistent reduction of air bypass
■■ Lightweight frame construction for easy handling and installation
Nested pleats for reduced pressure drop
Innovative, open filtration media structure
Integral gaskets reduce air bypass, keeping coils clean
MERV A14 Performance DataAir Velocity for ASHRAE Testing 492 fpm (1968 cfm for 24” x 24” filter)
Initial pressure drop 0.23” w.g.
Recommended final pressure drop 1.5” w.g.
Efficiency Rating per ASHRAE 52.2: 2007 MERV 151
Efficiency Rating per ASHRAE 52.2: 2007 Appendix J MERV A14
Dust Holding Capacity at 1.5” w.g. 235 g
MERV A14
0.0
0.1
0.2
0.3
0.4
0.5
0 100 200 300 400 500 600 700 800
Resi
stan
ce (i
nche
s of
wat
er)
.
Flow Rate (fpm)
Initial Filter Resistance
Initial Resistance vs Air Velocity Minimum Filter Efficiency vs. Particle Size at 492 fpm
Average Initial Pressure Drop is 0.23 inches of water @ 492 fpm
0
10
20
30
40
50
60
70
80
90
100
0 1 2 3 4 5 6 7 8 9 10
KCl E
ffici
ency
(%)
Particle Size (microns)
Filter Efficiency vs. Particle Size at 492 fpm per ASHRAE
Per ASHRAE 52.2: 2007
Per ASHRAE 52.2: 2007 Appendix J
MERV A15MERV A15 Performance DataAir Velocity for ASHRAE Testing 492 fpm (1968 cfm for 24” x 24” filter)
Initial pressure drop 0.26” w.g.
Recommended final pressure drop 1.5” w.g.
Efficiency Rating per ASHRAE 52.2: 2007 MERV 161
Efficiency Rating per ASHRAE 52.2: 2007 Appendix J MERV A15
Dust Holding Capacity at 1.5” w.g. 215 g
0
10
20
30
40
50
60
70
80
90
100
0 1 2 3 4 5 6 7 8 9 10
KCl E
ffici
ency
(%)
Particle Size (microns)
Filter Efficiency vs. Particle Size at 492 fpm per ASHRAE
Initial Resistance vs Air Velocity
Average Initial Pressure Drop is 0.26 inches of water @ 492 fpm
0.0
0.1
0.2
0.3
0.4
0.5
0.6
0 100 200 300 400 500 600 700 800
Resi
stan
ce (i
nche
s of
wat
er)
.
Flow Rate (fpm)
Initial Filter Resistance
Minimum Filter Efficiency vs. Particle Size at 492 fpm
Per ASHRAE 52.2: 2007
Per ASHRAE 52.2: 2007 Appendix J
Filter Measurements MERV A15 (MERV 16 Efficiency Rating per ASHRAE 52.2 - 2007)
Product No.
3M ID NumberProduct
No.3M ID Number Nominal Dimensions "A" x
"B" x "C" Inches (mm)
Width "A" Inches (mm)
Width "B" Inches (mm)
Width "C" Inches (mm)Standard Flow Reverse Flow
E739 70-0714-7184-4 E760 70-0714-7206-5 24 x 24 x 12 (610 x 610 x 305) 23 3/8 (594) 23 3/8 (594) 11.9 (302)
E740 70-0714-7185-1 E763 70-0714-7209-9 20 x 24 x 12 (508 x 610 x 305) 23 3/8 (594) 19 3/8 (492) 11.9 (302)
E741 70-0714-7186-9 E766 70-0714-7212-3 12 x 24 x 12 (305 x 610 x 305) 23 3/8 (594) 11 3/8 (289) 11.9 (302)
MERV A14 (MERV 15 Efficiency Rating per ASHRAE 52.2 - 2007)
Product No.
3M ID NumberProduct
No.3M ID Number Nominal Dimensions "A" x
"B" x "C" Inches (mm)
Width "A" Inches (mm)
Width "B" Inches (mm)
Width "C" Inches (mm)Standard Flow Reverse Flow
E733 70-0714-7178-6 E759 70-0714-7205-7 24 x 24 x 12 (610 x 610 x 305) 23 3/8 (594) 23 3/8 (594) 11.9 (302)
E734 70-0714-7179-4 E762 70-0714-7208-1 20 x 24 x 12 (508 x 610 x 305) 23 3/8 (594) 19 3/8 (492) 11.9 (302)
E735 70-0714-7180-2 E765 70-0714-7211-5 12 x 24 x 12 (305 x 610 x 305) 23 3/8 (594) 11 3/8 (289) 11.9 (302)
MERV A13 (MERV 14 Efficiency Rating per ASHRAE 52.2 - 2007)
Product No.
3M ID NumberProduct
No.3M ID Number Nominal Dimensions "A" x
"B" x "C" Inches (mm)
Width "A" Inches (mm)
Width "B" Inches (mm)
Width "C" Inches (mm)Standard Flow Reverse Flow
E736 70-0714-7181-0 E758 70-0714-7204-0 24 x 24 x 12 (610 x 610 x 305) 23 3/8 (594) 23 3/8 (594) 11.9 (302)
E737 70-0714-7182-8 E761 70-0714-7207-3 20 x 24 x 12 (508 x 610 x 305) 23 3/8 (594) 19 3/8 (492) 11.9 (302)
E738 70-0714-7183-6 E764 70-0714-7210-7 12 x 24 x 12 (305 x 610 x 305) 23 3/8 (594) 11 3/8 (289) 11.9 (302)
B
A
C
MERV A13 Performance DataAir Velocity for ASHRAE Testing 492 fpm (1968 cfm for 24” x 24” filter)
Initial pressure drop 0.21” w.g.
Recommended final pressure drop 1.5” w.g.
Efficiency Rating per ASHRAE 52.2: 2007 MERV 141
Efficiency Rating per ASHRAE 52.2: 2007 Appendix J MERV A13
Dust Holding Capacity at 1.5” w.g. 225 g
Important use restriction: This filter must not be used as a primary filter in hospitals and healthcare facilities where a MERV 14 primary filter is required per ASHRAE 170 - 2013. 3M recommends the use of 3M™ Commercial HVAC Filter Products with a minimum rating of MERV A14.
MERV A13
0.00
0.05
0.10
0.15
0.20
0.25
0.30
0.35
0.40
0.45
0 100 200 300 400 500 600 700 800
Resi
stan
ce (i
nche
s of
wat
er)
.
Flow Rate (fpm)
Initial Filter Resistance
Initial Resistance vs Air Velocity
Average Initial Pressure Drop is 0.21 inches of water @ 492 fpm
0
10
20
30
40
50
60
70
80
90
100
0 1 2 3 4 5 6 7 8 9 10
KCl E
ffici
ency
(%)
Particle Size (microns)
Filter Efficiency vs. Particle Size at 492 fpm per ASHRAE
Per ASHRAE 52.2: 2007
Per ASHRAE 52.2: 2007 Appendix J
Minimum Filter Efficiency vs. Particle Size at 492 fpm
Mini-pleat Filters with Gasket
■■ Low pressure drop for potential energy savings
■■ Long filter life
■■ Factory installed gaskets for consistent reduction of air bypass
■■ Simple, hassle-free installation without clips
3M™ Mini-Pleat Filters with Gasket combine effective filtration perfor-mance with low airflow resistance and long filter life, which can lead to lower energy consumption as well as reduced waste disposal volume and labor cost. Our customers value the filters’ properties that lead to time and money savings and help them keep their operating and maintenance budgets in line.
Glue beads maintain pleat spacing integrity
Integral gaskets prevent air bypass, keeping coils clean
No clips are required when installing
Key benefits■■ Significant energy savings possible when installed in place of standard filters due to low pressure drop achieved through the use of our highly refined electrostatically charged media (electret media), open filtration media structure and high surface area mini-pleat design.
■■ Longer filter life than competitive products due to the unique combination of depth loading filtration media, precise pleat structure and high filter media area.
■■ Mini-Pleat Filters with Gasket allow for simple upgrade of in-place filters, without additional capital expenditures.
■■ Minimized air bypass around and between filters, common in damaged or misaligned air handling racks, due to innovative filter frame with integrated gaskets.
■■ Reduced labor hours■• due to simple, hassle-free installation, supported by the innovative slip-rib frame design ■• due to longer filter life which results in fewer filter change-outs■• factory installed integral gaskets, which eliminate labor required to install and properly align
gaskets on site■• as no clips are required when installing 3M Mini-Pleat with gasket filters
■■ Far less storage space required compared to many filters of same efficiency resulting from the high performance 2” mini-pleat filter format.
■■ Significant energy value and low ash content resulting from 100% incinerable components of the filter and resistant to moisture and common chemicals.
■■ Tough filter construction resulting in low chance of filter damage during handling, installation and resistant to moisture amd common chemicals.
■■ Reliable performance in the most extreme commercial office building HVAC environments due to durable, moisture and humidity resistant, 100% synthetic filtration media, 100% metal free filter design and engineered frame construction.
■■ Superior product quality with consistent performance via rigorous ISO 9001 — 2008 certified manufacturing process, a full on-site HVAC laboratory testing facility and field testing capability.
■■ Available in MERV A8, MERV A11, MERV A12 and MERV A13, 3M™ Mini-Pleat Filters with Gasket are an excellent choice as either primary or as pre-filters in a variety of applications.
■■ The 3M Commercial HVAC Filter MERV A8, MERV A11 and MERV A12 contribute to earning a point in the LEED® certification process during the construction phase for new buildings and renovations.
■■ The 3M Commercial HVAC Filter MERV A13 Mini-Pleat with Gasket contributes to earning a point in the LEED® certification process for existing and new buildings by using the filter on all outside air intakes and inside air recirculation returns.
MERV A13 Performance DataAir Velocity for ASHRAE Testing 492 fpm (1968 cfm for 24" x 24" filter)
Initial Pressure Drop 0.39" w.g.
Recommended Final Pressure Drop 1.4" w.g.
Efficiency Rating per ASHRAE 52.2: 2007 MERV 14¹
Efficiency Rating per ASHRAE 52.2: 2007 Appendix J MERV A13
Dust Holding Capacity at 1.4" w.g. 95 ± 7 gI
MERV A13
0.00
0.10
0.20
0.30
0.40
0.50
0.60
Initi
al R
esis
tanc
e (in
ches
of w
ater
)
fpm0 100 200 300 400 500
0
10
20
30
40
50
60
70
80
90
100
0 1 2 3 4 5 6 7 8 9 10
KCl E
ffic
ienc
y (%
)
Particle Size (microns)
Per ASHRAE 52.2: 2007Per ASHRAE 52.2: 2007 Appendix J
Minimum Filter Efficiency vs. Particle Size at 492 fpm
Initial Pressure Drop vs. Air Velocity 24" x 24" Filter
A B
C
Filter MeasurementsProduct
No.3M ID Number
Nominal Dimensions “A” x “B” x “C” Inches (mm)
Width “A” Inches (mm)
Height “B” Inches (mm)
Depth “C” Inches (mm)
E675 70-0714-7119-0 10 x 10 x 2 (254 x 254 x 51) 9 3/8 (238) 9 3/8 (238) 1 7/8 (48)
E676 70-0714-7120-8 10 x 20 x 2 (254 x 508 x 51) 9 3/8 (238) 19 3/8 (492) 1 7/8 (48)
E677 70-0714-7121-6 12 x 20 x 2 (305 x 508 x 51) 11 3/8 (289) 19 3/8 (492) 1 7/8 (48)
E678 70-0714-7122-4 12 x 24 x 2 (305 x 610 x 51) 11 3/8 (289) 23 3/8 (594) 1 7/8 (48)
E679 70-0714-7123-2 14 x 20 x 2 (356 x 508 x 51) 13 3/8 (340) 19 3/8 (492) 1 7/8 (48)
E680 70-0714-7124-0 14 x 25 x 2 (356 x 635 x 51) 13 3/8 (340) 24 3/8 (619) 1 7/8 (48)
E681 70-0714-7125-7 15 x 20 x 2 (381 x 508 x 51) 14 3/8 (365) 19 3/8 (492) 1 7/8 (48)
E682 70-0714-7126-5 16 x 16 x 2 (406 x 406 x 51) 15 3/8 (391) 15 3/8 (391) 1 7/8 (48)
E683 70-0714-7127-3 16 x 20 x 2 (406 x 508 x 51) 15 3/8 (391) 19 3/8 (492) 1 7/8 (48)
E684 70-0714-7128-1 16 x 24 x 2 (406 x 610 x 51) 15 3/8 (391) 23 3/8 (594) 1 7/8 (48)
E685 70-0714-7129-9 16 x 25 x 2 (406 x 635 x 51) 15 3/8 (391) 24 3/8 (619) 1 7/8 (48)
E686 70-0714-7130-7 18 x 20 x 2 (457 x 508 x 51) 17 3/8 (441) 19 3/8 (492) 1 7/8 (48)
E687 70-0714-7131-5 18 x 24 x 2 (457 x 610 x 51) 17 3/8 (441) 23 3/8 (594) 1 7/8 (48)
E688 70-0714-7132-3 18 x 25 x 2 (457 x 635 x 51) 19 3/8 (492) 24 3/8 (619) 1 7/8 (48)
E689 70-0714-7133-1 20 x 20 x 2 (508 x 508 x 51) 19 3/8 (492) 19 3/8 (492) 1 7/8 (48)
E690 70-0714-7134-9 20 x 24 x 2 (508 x 610 x 51) 19 3/8 (492) 23 3/8 (594) 1 7/8 (48)
E691 70-0714-7135-6 20 x 25 x 2 (508 x 635 x 51) 19 3/8 (492) 24 3/8 (619) 1 7/8 (48)
E694 70-0714-7138-0 20 x 30 x 2 (508 x 762 x 51) 19 3/8 (492) 29 3/8 (746) 1 7/8 (48)
E692 70-0714-7136-4 24 x 24 x 2 (610 x 610 x 51) 23 3/8 (594) 23 3/8 (594) 1 7/8 (48)
E693 70-0714-7137-2 25 x 25 x 2 (635 x 635 x 51) 24 3/8 (619) 24 3/8 (619) 1 7/8 (48)
1 The particle capture efficiency will reduce in actual use. Please visit www.whatisMERVA.com for more information.
Average Initial Pressure Drop is 0.39”w.g.
Contributes to earning one point towards LEED®
certification process
MERV A12 Performance DataAir Velocity for ASHRAE Testing 492 fpm (1968 cfm for 24" x 24" filter)
Initial Pressure Drop 0.37" w.g.
Recommended Final Pressure Drop 1.4" w.g.
Efficiency Rating per ASHRAE 52.2: 2007 MERV 14¹
Efficiency Rating per ASHRAE 52.2: 2007 Appendix J MERV A12
Dust Holding Capacity at 1.4" w.g. 93 ± 21 g
MERV A12
40
50
60
70
80
90
0 1 2 3 4 5 6 7 8 9Particle Size (microns)
KCl E
ffic
ienc
y(%
)
Per ASHRAE 52.2-2007Per ASHRAE-2007 Appendix J
0.00
0.10
0.20
0.30
Initi
al P
ress
ure
Drop
(inc
hes
of w
ater
)
fpm100 200 300 400 500
100
30600 700
0.40
0.50
0.60
Minimum Filter Efficiency vs. Particle Size at 492 fpm
Initial Pressure Drop vs. Air Velocity 24" x 24" Filter
Average Initial Pressure Drop is 0.37” w.g.
A B
C
Filter MeasurementsProduct
No.3M ID Number
Nominal Dimensions “A” x “B” x “C” Inches (mm)
Width “A” Inches (mm)
Height “B” Inches (mm)
Depth “C” Inches (mm)
E133 70-0708-1943-1 10 x 10 x 2 (254 x 254 x 51) 9 3/8 (238) 9 3/8 (238) 1 7/8 (48)
E124 70-0708-1934-0 10 x 20 x 2 (254 x 508 x 51) 9 3/8 (238) 19 3/8 (492) 1 7/8 (48)
E125 70-0708-1935-7 12 x 20 x 2 (305 x 508 x 51) 11 3/8 (289) 19 3/8 (492) 1 7/8 (48)
F978 70-0708-1806-0 12 x 24 x 2 (305 x 610 x 51) 11 3/8 (289) 23 3/8 (594) 1 7/8 (48)
E126 70-0708-1936-5 14 x 20 x 2 (356 x 508 x 51) 13 3/8 (340) 19 3/8 (492) 1 7/8 (48)
E127 70-0708-1937-3 14 x 25 x 2 (356 x 635 x 51) 13 3/8 (340) 24 3/8 (619) 1 7/8 (48)
E136 70-0708-1946-4 15 x 20 x 2 (381 x 508 x 51) 14 3/8 (365) 19 3/8 (492) 1 7/8 (48)
E128 70-0708-1938-1 16 x 16 x 2 (406 x 406 x 51) 15 3/8 (391) 15 3/8 (391) 1 7/8 (48)
F979 70-0708-1807-8 16 x 20 x 2 (406 x 508 x 51) 15 3/8 (391) 19 3/8 (492) 1 7/8 (48)
E129 70-0708-1939-9 16 x 24 x 2 (406 x 610 x 51) 15 3/8 (391) 23 3/8 (594) 1 7/8 (48)
F980 70-0708-1808-6 16 x 25 x 2 (406 x 635 x 51) 15 3/8 (391) 24 3/8 (619) 1 7/8 (48)
E132 70-0708-1942-3 18 x 20 x 2 (457 x 508 x 51) 17 3/8 (441) 19 3/8 (492) 1 7/8 (48)
F981 70-0708-1890-4 18 x 24 x 2 (457 x 610 x 51) 17 3/8 (441) 23 3/8 (594) 1 7/8 (48)
E130 70-0708-1940-7 18 x 25 x 2 (457 x 635 x 51) 19 3/8 (492) 24 3/8 (619) 1 7/8 (48)
F977 70-0708-1805-2 20 x 20 x 2 (508 x 508 x 51) 19 3/8 (492) 19 3/8 (492) 1 7/8 (48)
E131 70-0708-1941-5 20 x 24 x 2 (508 x 610 x 51) 19 3/8 (492) 23 3/8 (594) 1 7/8 (48)
F982 70-0708-1810-2 20 x 25 x 2 (508 x 635 x 51) 19 3/8 (492) 24 3/8 (619) 1 7/8 (48)
E134 70-0708-1944-9 20 x 30 x 2 (508 x 762 x 51) 19 3/8 (492) 29 3/8 (746) 1 7/8 (48)
F976 70-0708-1804-5 24 x 24 x 2 (610 x 610 x 51) 23 3/8 (594) 23 3/8 (594) 1 7/8 (48)
E135 70-0708-1945-6 25 x 25 x 2 (635 x 635 x 51) 24 3/8 (619) 24 3/8 (619) 1 7/8 (48)
1 The particle capture efficiency will reduce in actual use. Please visit www.whatisMERVA.com for more information.
MERV A11 Performance DataAir Velocity for ASHRAE Testing 492 fpm (1968 cfm for 24" x 24" filter)
Initial Pressure Drop 0.25" w.g.
Recommended Final Pressure Drop 1.4" w.g.
Efficiency Rating per ASHRAE 52.2: 2007 MERV 12¹
Efficiency Rating per ASHRAE 52.2: 2007 Appendix J MERV A11
Dust Holding Capacity at 1.4" w.g. 110 ± 17 g
MERV A11
40
50
60
70
80
90
0 1 2 3 4 5 6 7 8 9Particle Size (microns)
KCl E
ffic
ienc
y(%
)
Per ASHRAE 52.2: 2007Per ASHRAE 52.2: 2007 Appendix J
0.0
0.1
0.2
0.3
Initi
al P
ress
ure
Drop
(inc
hes
of w
ater
)
Flow Rate (fpm)0 100 200 300 400 500
100
30
20
Minimum Filter Efficiency vs. Particle Size at 492 fpm
Initial Pressure Drop vs. Air Velocity 24" x 24" Filter
Average Initial Pressure Drop is 0.25 inches w.g.
A B
C
Filter MeasurementsProduct
No.3M ID Number
Nominal Dimensions “A” x “B” x “C” Inches (mm)
Width “A” Inches (mm)
Height “B” Inches (mm)
Depth “C” Inches (mm)
E695 70-0714-7139-8 10 x 10 x 2 (254 x 254 x 51) 9 3/8 (238) 9 3/8 (238) 1 7/8 (48)
E696 70-0714-7140-6 10 x 20 x 2 (254 x 508 x 51) 9 3/8 (238) 19 3/8 (492) 1 7/8 (48)
E697 70-0714-7141-4 12 x 20 x 2 (305 x 508 x 51) 11 3/8 (289) 19 3/8 (492) 1 7/8 (48)
E698 70-0714-7142-2 12 x 24 x 2 (305 x 610 x 51) 11 3/8 (289) 23 3/8 (594) 1 7/8 (48)
E699 70-0714-7143-0 14 x 20 x 2 (356 x 508 x 51) 13 3/8 (340) 19 3/8 (492) 1 7/8 (48)
E700 70-0714-7144-8 14 x 25 x 2 (356 x 635 x 51) 13 3/8 (340) 24 3/8 (619) 1 7/8 (48)
E701 70-0714-7145-5 15 x 20 x 2 (381 x 508 x 51) 14 3/8 (365) 19 3/8 (492) 1 7/8 (48)
E702 70-0714-7146-3 16 x 16 x 2 (406 x 406 x 51) 15 3/8 (391) 15 3/8 (391) 1 7/8 (48)
E703 70-0714-7147-1 16 x 20 x 2 (406 x 508 x 51) 15 3/8 (391) 19 3/8 (492) 1 7/8 (48)
E704 70-0714-7148-9 16 x 24 x 2 (406 x 610 x 51) 15 3/8 (391) 23 3/8 (594) 1 7/8 (48)
E705 70-0714-7149-7 16 x 25 x 2 (406 x 635 x 51) 15 3/8 (391) 24 3/8 (619) 1 7/8 (48)
E706 70-0714-7150-5 18 x 20 x 2 (457 x 508 x 51) 17 3/8 (441) 19 3/8 (492) 1 7/8 (48)
E707 70-0714-7151-3 18 x 24 x 2 (457 x 610 x 51) 17 3/8 (441) 23 3/8 (594) 1 7/8 (48)
E708 70-0714-7152-1 18 x 25 x 2 (457 x 635 x 51) 19 3/8 (492) 24 3/8 (619) 1 7/8 (48)
E709 70-0714-7153-9 20 x 20 x 2 (508 x 508 x 51) 19 3/8 (492) 19 3/8 (492) 1 7/8 (48)
E710 70-0714-7154-7 20 x 24 x 2 (508 x 610 x 51) 19 3/8 (492) 23 3/8 (594) 1 7/8 (48)
E711 70-0714-7155-4 20 x 25 x 2 (508 x 635 x 51) 19 3/8 (492) 24 3/8 (619) 1 7/8 (48)
E714 70-0714-7158-8 20 x 30 x 2 (508 x 762 x 51) 19 3/8 (492) 29 3/8 (746) 1 7/8 (48)
E712 70-0714-7156-2 24 x 24 x 2 (610 x 610 x 51) 23 3/8 (594) 23 3/8 (594) 1 7/8 (48)
E713 70-0714-7157-0 25 x 25 x 2 (635 x 635 x 51) 24 3/8 (619) 24 3/8 (619) 1 7/8 (48)
40
50
60
70
80
90
0 1 2 3 4 5 6 7 8 9Particle Size (microns)
KCl E
ffic
ienc
y(%
)
Per ASHRAE 52.2: 2007Per ASHRAE 52.2: 2007 Appendix J
0.0
0.1
0.2
0.3
Initi
al P
ress
ure
Drop
(inc
hes
of w
ater
)
Flow Rate (fpm)0 100 200 300 400 500
100
30
20
MERV A8 Performance DataAir Velocity for ASHRAE Testing 492 fpm (1968 cfm for 24" x 24" filter)
Initial Pressure Drop 0.26" w.g.
Recommended Final Pressure Drop 1.4" w.g.
Efficiency Rating per ASHRAE 52.2: 2007 MERV 11¹
Efficiency Rating per ASHRAE 52.2: 2007 Appendix J MERV A8
Dust Holding Capacity at 1.4" w.g. 90 ± 15 g
MERV A8
40
50
60
70
80
90
0 1 2 3 4 5 6 7 8 9Particle Size (microns)
KCl E
ffic
ienc
y(%
)
Per ASHRAE 52.2: 2007 Per ASHRAE 52.2: 2007 Appendix J
0.00
0.10
0.20
0.30
Initi
al P
ress
ure
Drop
(inc
hes
of w
ater
)
fpm100 200 300 400 500
100
30
600 700
0.40
20
Minimum Filter Efficiency vs. Particle Size at 492 fpm
Initial Pressure Drop vs. Air Velocity 24" x 24" Filter
Average Initial Pressure Drop is 0.26” w.g.
A B
C
Filter MeasurementsProduct
No.3M ID Number
Nominal Dimensions “A” x “B” x “C” Inches (mm)
Width “A” Inches (mm)
Height “B” Inches (mm)
Depth “C” Inches (mm)
E276 70-0712-4438-1 10 x 10 x 2 (254 x 254 x 51) 9 3/8 (238) 9 3/8 (238) 1 7/8 (48)
E277 70-0712-4439-9 10 x 20 x 2 (254 x 508 x 51) 9 3/8 (238) 19 3/8 (492) 1 7/8 (48)
E278 70-0712-4440-7 12 x 20 x 2 (305 x 508 x 51) 11 3/8 (289) 19 3/8 (492) 1 7/8 (48)
E279 70-0712-4441-5 12 x 24 x 2 (305 x 610 x 51) 11 3/8 (289) 23 3/8 (594) 1 7/8 (48)
E280 70-0712-4442-3 14 x 20 x 2 (356 x 508 x 51) 13 3/8 (340) 19 3/8 (492) 1 7/8 (48)
E281 70-0712-4443-1 14 x 25 x 2 (356 x 635 x 51) 13 3/8 (340) 24 3/8 (619) 1 7/8 (48)
E282 70-0712-4444-9 15 x 20 x 2 (381 x 508 x 51) 14 3/8 (365) 19 3/8 (492) 1 7/8 (48)
E283 70-0712-4445-6 16 x 16 x 2 (406 x 406 x 51) 15 3/8 (391) 15 3/8 (391) 1 7/8 (48)
E284 70-0712-4446-4 16 x 20 x 2 (406 x 508 x 51) 15 3/8 (391) 19 3/8 (492) 1 7/8 (48)
E285 70-0712-4447-2 16 x 24 x 2 (406 x 610 x 51) 15 3/8 (391) 23 3/8 (594) 1 7/8 (48)
E286 70-0712-4448-0 16 x 25 x 2 (406 x 635 x 51) 15 3/8 (391) 24 3/8 (619) 1 7/8 (48)
E287 70-0712-4449-8 18 x 20 x 2 (457 x 508 x 51) 17 3/8 (441) 19 3/8 (492) 1 7/8 (48)
E288 70-0712-4450-6 18 x 24 x 2 (457 x 610 x 51) 17 3/8 (441) 23 3/8 (594) 1 7/8 (48)
E289 70-0712-4451-4 18 x 25 x 2 (457 x 635 x 51) 19 3/8 (492) 24 3/8 (619) 1 7/8 (48)
E290 70-0712-4452-2 20 x 20 x 2 (508 x 508 x 51) 19 3/8 (492) 19 3/8 (492) 1 7/8 (48)
E291 70-0712-4453-0 20 x 24 x 2 (508 x 610 x 51) 19 3/8 (492) 23 3/8 (594) 1 7/8 (48)
E292 70-0712-4454-8 20 x 25 x 2 (508 x 635 x 51) 19 3/8 (492) 24 3/8 (619) 1 7/8 (48)
E293 70-0712-4455-5 20 x 30 x 2 (508 x 762 x 51) 19 3/8 (492) 29 3/8 (746) 1 7/8 (48)
E294 70-0712-4456-3 24 x 24 x 2 (610 x 610 x 51) 23 3/8 (594) 23 3/8 (594) 1 7/8 (48)
E295 70-0712-4457-1 25 x 25 x 2 (635 x 635 x 51) 24 3/8 (619) 24 3/8 (619) 1 7/8 (48)
Mini-Pleat Filters, No Gasket
Key benefits
�� Increased air flow or lower fan energy consumption compared to equivalent filter design and efficiency of competitors
�� Electrostatically charged, open construction media
�� Durable synthetic media and frame construction
�� Long filter life
■• Media loads through the depth of the filter■• Mini-pleat construction provides high surface area�� Small Package Size — Easy to handle, low disposal volume, low shipping costs
�� Demonstrated filtration efficiency
�� Lightweight, rigid frame
■■ Low pressure drop for potential energy savings
■■ Long filter life
■■ Tough filter and frame construction resulting in low chance of filter damage during handling, installation or use in humid environments
100% Synthetic media-filters are very durable:• Lesschanceoffilterdamage
during handling and installation
• Resistanttomoistureand common chemicals
• Resistanttofibershedding
3M™ Commercial HVAC Filter MERV A8 and A12 Mini-Pleat Filters without Gaskets combine excellent filtration performance with low airflow resistance and long filter life in a cost effective construction. Their balance of properties may offer building owners and managers time and money savings.
Mini-Pleat Filters, No GasketMERV A12 Performance DataAir Velocity for ASHRAE Testing 492 fpm (1968 cfm for 24” x 24” filter)
Initial Resistance 0.37 inches of water
Recommended Final Resistance 1.4 inches of water
Efficiency Rating per ASHRAE 52.2: 2007 MERV 141
Efficiency Rating per ASHRAE 52.2: 2007 Appendix J MERV A12
Average Dust Holding Capacity at 1.4 inches of water 93±21g
MER
V A1
2
Initial Resistance vs. Air Velocity Resistance vs. Dust Loading @ 492 fpm
0.00
0.10
0.20
0.30
0.40
0.50
0.60
Initi
al R
esis
tanc
e (in
ches
of w
ater
)
Flow Rate (fpm) 0 100 200 300 400 500 600 700
Inches
0.0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
0 10 20 30 40 50 60 70 80ASHRAE Dust Fed (g)
Resi
stan
ce (i
nche
s of
wat
er)
Inches
Filter Measurements
A B
C
Product No.
Stock No.Nominal Dimensions
Inches (mm)Width “A”
Inches (mm)Height “B”
Inches (mm)Depth “C”
Inches (mm)
E358 70-0712-4567-7 10 x 10 x 2 (254 x 254 x 51) 9 3/8 (238) 9 3/8 (238) 1 7/8 (48)
E359 70-0712-4568-5 10 x 20 x 2 (254 x 508 x 51) 9 3/8 (238) 19 3/8 (492) 1 7/8 (48)
E360 70-0712-4569-3 12 x 20 x 2 (305 x 508 x 51) 11 3/8 (289) 19 3/8 (492) 1 7/8 (48)
E361 70-0712-4570-1 12 x 24 x 2 (305 x 610 x 51) 11 3/8 (289) 23 3/8 (594) 1 7/8 (48)
E362 70-0712-4571-9 14 x 20 x 2 (356 x 508 x 51) 13 3/8 (340) 19 3/8 (492) 1 7/8 (48)
E363 70-0712-4572-7 14 x 25 x 2 (356 x 635 x 51) 13 3/8 (340) 24 3/8 (619) 1 7/8 (48)
E364 70-0712-4573-5 15 x 20 x 2 (381 x 508 x 51) 14 3/8 (365) 19 3/8 (492) 1 7/8 (48)
E365 70-0712-4574-3 16 x 16 x 2 (406 x 406 x 51) 15 3/8 (391) 15 3/8 (391) 1 7/8 (48)
E366 70-0712-4575-0 16 x 20 x 2 (406 x 508 x 51) 15 3/8 (391) 19 3/8 (492) 1 7/8 (48)
E367 70-0712-4576-8 16 x 24 x 2 (406 x 610 x 51) 15 3/8 (391) 23 3/8 (594) 1 7/8 (48)
E368 70-0712-4577-6 16 x 25 x 2 (406 x 635 x 51) 15 3/8 (391) 24 3/8 (619) 1 7/8 (48)
E369 70-0712-4578-4 18 x 20 x 2 (457 x 508 x 51) 17 3/8 (441) 19 3/8 (492) 1 7/8 (48)
E370 70-0712-4579-2 18 x 24 x 2 (457 x 610 x 51) 17 3/8 (441) 23 3/8 (594) 1 7/8 (48)
E371 70-0712-4580-0 18 x 25 x 2 (457 x 634 x 51) 19 3/8 (492) 24 3/8 (619) 1 7/8 (48)
E372 70-0712-4581-8 20 x 20 x 2 (508 x 508 x 51) 19 3/8 (492) 19 3/8 (492) 1 7/8 (48)
E373 70-0712-4582-6 20 x 24 x 2 (508 x 610 x 51) 19 3/8 (492) 23 3/8 (594) 1 7/8 (48)
E374 70-0712-4583-4 20 x 25 x 2 (508 x 635 x 51) 19 3/8 (492) 24 3/8 (619) 1 7/8 (48)
E375 70-0712-4584-2 20 x 30 x 2 (508 x 762 x 51) 19 3/8 (492) 29 3/8 (746) 1 7/8 (48)
E376 70-0712-4585-9 24 x 24 x 2 (610 x 610 x 51) 23 3/8 (594) 23 3/8 (594) 1 7/8 (48)
E377 70-0712-4586-7 25 x 25 x 2 (635 x 635 x 51) 24 3/8 (619) 24 3/8 (619) 1 7/8 (48)
MERV A8 Performance DataAir Velocity for ASHRAE Testing 492 fpm (1968 cfm for 24” x 24” filter)
Initial Resistance 0.26±0.01 inches of water
Recommended Final Resistance 1.4 inches of water
Efficiency Rating per ASHRAE 52.2: 2007 MERV 111
Efficiency Rating per ASHRAE 52.2: 2007 Appendix J MERV A8
Average Dust Holding Capacity at 1.4 inches of water 90±15g
MER
V A8
Initial Resistance vs. Air Velocity Resistance vs. Dust Loading @ 492 fpm
0.0
0.1
0.2
0.3
0.4
0 100 200 300 400 500 600 700Flow Rate (fpm)
Resi
stan
ce (i
nche
s of
wat
er)
0.0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
0 20 40 60 80 100
ASHRAE Dust Fed (g)Re
sist
ance
(inc
hes
of w
ater
)
Filter Measurements
A B
C
Product No.
Stock No.Nominal Dimensions
Inches (mm)Width “A”
Inches (mm)Height “B”
Inches (mm)Depth “C”
Inches (mm)
E324 70-0712-4480-3 10 x 10 x 2 (254 x 254 x 51) 9 3/8 (238) 9 3/8 (238) 1 7/8 (48)
E325 70-0712-4481-1 10 x 20 x 2 (254 x 508 x 51) 9 3/8 (238) 19 3/8 (492) 1 7/8 (48)
E326 70-0712-4482-9 12 x 20 x 2 (305 x 508 x 51) 11 3/8 (289) 19 3/8 (492) 1 7/8 (48)
E327 70-0712-4483-7 12 x 24 x 2 (305 x 610 x 51) 11 3/8 (289) 23 3/8 (594) 1 7/8 (48)
E328 70-0712-4484-5 14 x 20 x 2 (356 x 508 x 51) 13 3/8 (340) 19 3/8 (492) 1 7/8 (48)
E329 70-0712-4485-2 14 x 25 x 2 (356 x 635 x 51) 13 3/8 (340) 24 3/8 (619) 1 7/8 (48)
E330 70-0712-4486-0 15 x 20 x 2 (381 x 508 x 51) 14 3/8 (365) 19 3/8 (492) 1 7/8 (48)
E331 70-0712-4487-8 16 x 16 x 2 (406 x 406 x 51) 15 3/8 (391) 15 3/8 (391) 1 7/8 (48)
E332 70-0712-4540-4 16 x 20 x 2 (406 x 508 x 51) 15 3/8 (391) 19 3/8 (492) 1 7/8 (48)
E333 70-0712-4541-2 16 x 24 x 2 (406 x 610 x 51) 15 3/8 (391) 23 3/8 (594) 1 7/8 (48)
E334 70-0712-4542-0 16 x 25 x 2 (406 x 635 x 51) 15 3/8 (391) 24 3/8 (619) 1 7/8 (48)
E335 70-0712-4543-8 18 x 20 x 2 (457 x 508 x 51) 17 3/8 (441) 19 3/8 (492) 1 7/8 (48)
E336 70-0712-4544-6 18 x 24 x 2 (457 x 610 x 51) 17 3/8 (441) 23 3/8 (594) 1 7/8 (48)
E337 70-0712-4545-3 18 x 25 x 2 (457 x 634 x 51) 19 3/8 (492) 24 3/8 (619) 1 7/8 (48)
E338 70-0712-4546-1 20 x 20 x 2 (508 x 508 x 51) 19 3/8 (492) 19 3/8 (492) 1 7/8 (48)
E339 70-0712-4547-9 20 x 24 x 2 (508 x 610 x 51) 19 3/8 (492) 23 3/8 (594) 1 7/8 (48)
E340 70-0712-4548-7 20 x 25 x 2 (508 x 635 x 51) 19 3/8 (492) 24 3/8 (619) 1 7/8 (48)
E341 70-0712-4549-5 20 x 30 x 2 (508 x 762 x 51) 19 3/8 (492) 29 3/8 (746) 1 7/8 (48)
E342 70-0712-4550-3 24 x 24 x 2 (610 x 610 x 51) 23 3/8 (594) 23 3/8 (594) 1 7/8 (48)
E343 70-0712-4551-1 25 x 25 x 2 (635 x 635 x 51) 24 3/8 (619) 24 3/8 (619) 1 7/8 (48)
High Air Flow (HAF) Filters
The open channel construction of 3M HAF filters offers low initial airflow resistance, while its unique micro-structure and electrostatic charge provides effective particle capture and retention. In certain applications, this may translate into fewer filter changeouts, reduced coil cleaning, and reduced maintenance costs.
Microstructured Features
Airflow
Filter Measurements
A B
C
Height “A” Inches (mm) max
Length “B” Inches (mm) max
Available Thicknesses “C” Inches (mm)
27.56 (700)
47.24 (1200)
0.20, 0.39, 0.59, 0.79, 0.98, 1.18 (5, 10, 15, 20, 25, 30)
A balanced approach to improved air filtration3M™ HAF Air Filters may offer an ideal alternative in applications where regular filter replacement is difficult or impractical, but where low airflow resistance is important.
Developed using innovative 3M technologies, 3M HAF Air Filters are frameless, self-supporting, and are constructed from an array of open flow channels. These filters are electrostatically charged for enhanced particle capture and retention.
3M HAF Air Filters are available with an antimicrobial agent to help inhibit the growth of mold and mildew on the filter media. Users should be aware that mold and mildew may grow on captured particles that build up over time on the filter.
Physical characteristics•Openchannelstructure
•Microstructured,electrostaticallychargedmedia(refertoPerformanceDataonnextpage)
•100%syntheticmedia
•Self-supportingfilter
•Standard:White
•Antimicrobial:Green
3M is a trademark of 3M Company.LEED is a trademark of the U.S. Green Building Council.© 2014 3M Company. All rights reserved.Please recycle. Printed in U.S.A.70020314087REV 0514
3M Purification Inc.400 Research ParkwayMeriden, CT 06450U.S.A. (800) 648-3550(651) 789-7381www.3Mpurification.com/airfilters
Your Local Distributor:
Additional InformationFor questions or to place an order in the U.S., contact your local 3M Purification Inc. distributor or 3M Purification Inc. Customer Service at (800) 648-3550 or (651) 789-7381
IMPORTANT NOTICE: The information in this literature is based on tests 3M believes are reliable. It is not and should not be relied on as a product or technical specification. We do not guarantee the accuracy of this information. If any products described in this literature are defective, 3M will replace them at no charge. THERE ARE NO OTHER EXPRESS OR IMPLIED WARRANTIES FOR THESE PRODUCTS, INCLUDING, BUT NOT LIMITED TO ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. You are responsible for determining whether products described in this literature are fit for a particular purpose and suitable for your application. Because there are many factors within your knowledge and control that might affect the use and performance of these products, you must evaluate these products to determine whether they are fit for a particular purpose, are suitable for your application, and meet your performance expectations. 3M IS NOT LIABLE FOR ANY LOSS OR DAMAGES, WHETHER DIRECT, INDIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL ARISING OUT OF THE USE OF OR INABILITY TO USE ANY OF THESE PRODUCTS.
CAUTION: USED FILTERS MAY CONTAIN CONTAMINANTS FROM OPERATION OF THE HVAC SYSTEM. FOR PROPER HANDLING OF USED FILTERS, CONSULT APPLICABLE HEALTH AND SAFETY STANDARDS OR CONTACT AN INDUSTRIAL HYGIENIST. TO REDUCE RISK OF ILLNESS OR INJURY, ALWAYS USE APPROPRIATE RESPIRATORY PROTECTION AND PROTECTIVE CLOTHING WHEN REMOVING OR HANDLING USED FILTERS. DISPOSE OF USED FILTERS ONLY IN ACCORDANCE WITH FEDERAL, STATE AND LOCAL LAWS AND REGULATIONS.
IMPORTANT USE RESTRICTIONS: DO NOT EXPOSE THIS FILTER DIRECTLY TO UV RADIATION FROM A UV PURIFICATION SYSTEM. EXCESSIVE UV EXPOSURE MAY LEAD TO A REDUCTION IN THE MECHANICAL INTEGRITY AND PERFORMANCE OF THE FILTER. THIS FILTER MUST NOT BE USED FOR THE FOLLOWING UNAUTHORIZED USES: A) ASBESTOS, LEAD OR MOLD REMEDIATION; B) BIOTERRORISM PROTECTION; C) APPLICATIONS IN BUILDINGS THAT REQUIRE OR ARE UNDERGOING AIR HANDLING SYSTEM REMEDIATION OF HAZARDOUS SUBSTANCES; OR (D) PROTECTIVE ENVIRONMENTS PER AIA GUIDELINES.