      Vortex Breaker03/10/2008 6:33 AM

    What is vortex breaker and how can we get the effectiveness of the vortex breaker for the same envisaged for the outlet pie from thbottom of the tank and going to Pump suction. For example pipe going to Boiler Feed pump from the Deaearator storage tank outlet.

    Interested in this topic? By joining CR4 you can "subscribe" tothis discussion and receive notification when new comments are added.

    Join CR4, The Engineer's Place for News and Discussion!

    Comments rated to be Good Answers:

    These comments received enough positive ratings to make them "good answers".

    #3 "Re: Vortex Breaker " by Abdel Halim Galala  on 03/11/2008 12:24 AM (score 2)#4 "Re: Vortex Breaker " by phoenix911  on 03/11/2008 1:42 PM (score 2)

    Comments rated to be "almost" Good Answers:

    Check out these comments that don't yet have enough votes to be "official" good answers and, if you agree with them, rate them!

    #7 "Re: Vortex Breaker " by chaterpilar  on 03/30/2008 10:12 AM (score 1)

    HendrikGuru

     

    Join Date: Jan 2007Location: Centurion,South AfricaPosts: 3908Good Answers: 96

     Re: Vortex breaker03/10/2008 7:12 AM

    A emergency fix is to drop a few planks into the suction pit. It prevent circular flow and a vortex from forming.

    This same idea can be followed by placing baffles in the pit.

    The energy of the inlet flow should also be dissipated otherwise it may cause a circular motion.

    Mr Coriolis should also be banned.

     __________________Never do today what you can put of until tomorrow - Student motto

    PWSlackGuru

     

    Join Date: Jan 2007Location: In the bothy, 7chains down the line fromDodman's Lane levelcrossing, in the nationformerly known as GreatBritain. Kettle's on.Posts: 24240Good Answers: 627

      Re: Vortex Breaker03/10/2008 10:02 AM

    A simple vortex breaker can be made as follows:

    From the same materials-of-construction of the tank, cut three pieces of flat sheet, in the form of a long right-angled triangle, lthan the 5:12:13 right-angled triangle, for illustrative purposes. The "5" side should be longer than 2/3 of the diameter of the opipe, so that when the vortex breaker is assembled, it is too large to pass into the tank outlet pipe.Fasten the "12" sides together so as to form a structure similar to the head of a 3-sided arrow.Position the sharp end of the arrow inside the outlet connection of the tank, so that it cannot pass into the outlet pipe.

    Bingo. One vortex breaker.

    Products to this design may be found in the KrisDelTM catalogue (usual disclaimer), though Stinky Pete may have squirrelled one aw

    somewhere.....

     __________________"Did you get my e-mail?" - "The biggest problem in communication is the illusion that it has taken place" - George Bernard Shaw, 18

    Abdel HalimGalalaGuru

      Re: Vortex Breaker03/11/2008 12:24 AM

    The vortex breaker is re quired to be furnished into the outlet nozzle of liquid discharging from a tank/vessel to prevent swirl ing of flowhat we call vortex which allows the surface of the liquid at the area above the nozzle to be lowered (like a cone its base at the surfthe liquid and its head at the nozzle) until gas/air inside the vessel transmitted through that nozzle going with the liquid. This gas/airwith the liquid causing a case of bad operation or can reach the impeller of a pump which causing too a bad operation to the pump. T

    2

    Home  News &

    Analysis

    Products &

    Suppliers

    Standards

    Library

    Reference

    Library

    Engineering

    Community

    Stay

    Informed  Free Regist

    Search Community Community   G

    CR4 - The Engineer's Place for News and Discussion ® Login | Register for Engineering Communit

    http://cr4.globalspec.com/group/member/438http://cr4.globalspec.com/group/member/1036http://cr4.globalspec.com/member/4035/Hendrikhttps://googleads.g.doubleclick.net/aclk?sa=L&ai=BjJAt1R_-VtfnEpSSvgSd_aq4Ade_wJ4IAAAAEAEgr_-eHzgAWP_igv3aAmDpgoCAhA6yARJjcjQuZ2xvYmFsc3BlYy5jb226AQlnZnBfaW1hZ2XIAQLaATFodHRwOi8vZ2xvYmFsc3BlYy5jb20vdGhyZWFkLzE4NzIwL1ZvcnRleC1CcmVha2VywAIC4AIA6gIuLzQyNTAvZW5naW5lZXJpbmczNjAvY3I0L01lY2hhbmljYWxFbmdpbmVlcmluZ_gC9NEekAOwCZgD4AOoAwHIA5kE0ASQTuAEAdIFBRDXuN5rkAYBoAYU2AcB4AcP&num=0&cid=5GhbLvnpcU0zL0MvC1hZfKHh&sig=AOD64_1Bo4KLngD_iX8qaLs1x_RUKAtENQ&client=ca-pub-6035513853108979&adurl=https://engineering.purdue.edu/ProEd/%3Fsource%3Dengineering360&nm=1https://googleads.g.doubleclick.net/aclk?sa=L&ai=BjJAt1R_-VtfnEpSSvgSd_aq4Ade_wJ4IAAAAEAEgr_-eHzgAWP_igv3aAmDpgoCAhA6yARJjcjQuZ2xvYmFsc3BlYy5jb226AQlnZnBfaW1hZ2XIAQLaATFodHRwOi8vZ2xvYmFsc3BlYy5jb20vdGhyZWFkLzE4NzIwL1ZvcnRleC1CcmVha2VywAIC4AIA6gIuLzQyNTAvZW5naW5lZXJpbmczNjAvY3I0L01lY2hhbmljYWxFbmdpbmVlcmluZ_gC9NEekAOwCZgD4AOoAwHIA5kE0ASQTuAEAdIFBRDXuN5rkAYBoAYU2AcB4AcP&num=0&cid=5GhbLvnpcU0zL0MvC1hZfKHh&sig=AOD64_1Bo4KLngD_iX8qaLs1x_RUKAtENQ&client=ca-pub-6035513853108979&adurl=https://engineering.purdue.edu/ProEd/%3Fsource%3Dengineering360&nm=1http://www.globalspec.com/?frmtrk=global-navhttp://insights.globalspec.com/http://www.globalspec.com/productfinder?frmtrk=global-navhttp://standards.globalspec.com/?frmtrk=global-navhttp://reference.globalspec.com/?frmtrk=global-navhttp://cr4.globalspec.com/http://cr4.globalspec.com/user/registerhttp://cr4.globalspec.com/user/login?redirectAfterLogin=%2Fthread%2F18720%2FVortex-Breakerhttp://www.globalspec.com/http://www.globalspec.com/MyGlobalSpec/NewProfile?PostRegURLToGoTo=http%3A%2F%2Fcr4%2Eglobalspec%2Ecom%2Fthread%2F18720%2FVortex%2DBreakerhttp://cr4.globalspec.com/http://reference.globalspec.com/?frmtrk=global-navhttp://standards.globalspec.com/?frmtrk=global-navhttp://www.globalspec.com/productfinder?frmtrk=global-navhttp://insights.globalspec.com/http://www.globalspec.com/?frmtrk=global-navhttps://googleads.g.doubleclick.net/aclk?sa=L&ai=BjJAt1R_-VtfnEpSSvgSd_aq4Ade_wJ4IAAAAEAEgr_-eHzgAWP_igv3aAmDpgoCAhA6yARJjcjQuZ2xvYmFsc3BlYy5jb226AQlnZnBfaW1hZ2XIAQLaATFodHRwOi8vZ2xvYmFsc3BlYy5jb20vdGhyZWFkLzE4NzIwL1ZvcnRleC1CcmVha2VywAIC4AIA6gIuLzQyNTAvZW5naW5lZXJpbmczNjAvY3I0L01lY2hhbmljYWxFbmdpbmVlcmluZ_gC9NEekAOwCZgD4AOoAwHIA5kE0ASQTuAEAdIFBRDXuN5rkAYBoAYU2AcB4AcP&num=0&cid=5GhbLvnpcU0zL0MvC1hZfKHh&sig=AOD64_1Bo4KLngD_iX8qaLs1x_RUKAtENQ&client=ca-pub-6035513853108979&adurl=https://engineering.purdue.edu/ProEd/%3Fsource%3Dengineering360&nm=1http://cr4.globalspec.com/member/4893/Abdel-Halim-Galalahttp://cr4.globalspec.com/group/member/126http://cr4.globalspec.com/group/member/55http://cr4.globalspec.com/member/4159/PWSlackhttp://cr4.globalspec.com/member/4159/PWSlackhttp://cr4.globalspec.com/group/member/1681http://cr4.globalspec.com/group/member/1036http://cr4.globalspec.com/group/member/573http://cr4.globalspec.com/group/member/438http://cr4.globalspec.com/group/member/414http://cr4.globalspec.com/member/4035/Hendrikhttp://cr4.globalspec.com/member/4035/Hendrikhttp://cr4.globalspec.com/user/registerhttp://cr4.globalspec.com/thread/18724/How-to-Disribute-Conditioning-Airhttp://cr4.globalspec.com/thread/18705/design

  • 8/17/2019 CR4 - Thread_ Vortex Breaker

    2/4

    In reply

    In reply

    In reply

    In reply t

    In reply t

    Join Date: Feb 2007Location: Cairo, EgyptPosts: 1746Good Answers: 241

    vortex breaker avoids that swirling or vortex formation.

    There are a lot of types and designs of vortex breakers. There are a many sites handling with that phenomenon such as Chemical pladesign  & operations - vortex  at the tank outlet

     __________________It is better to be defeated on principles, than to win on lies!

    Go to Next Good

    mbaz_81Active Contributor

    Join Date: Aug 2007Posts: 11

      Re: Vortex Breaker12/27/2009 4:40 AM

    Thanks abo galala .... as usual simple answer with numerous benefits....urs mbaz

    Abdel HalimGalalaGuru

     

    Join Date: Feb 2007Location: Cairo, EgyptPosts: 1746Good Answers: 241

      Re: Vortex Breaker12/28/2009 12:37 AM

    Thank you mbaz_81,

    You are welcome, but why your sharing is only 5 posts  since Aug 2007, we look for many participations.

    For that CR4 Thread title, you can also see: Vortex Problems in Pump Applications.

     __________________

    It is better to be defeated on principles, than to win on lies!

    Azhar AliParticipant

    Join Date: Sep 2010Posts: 1

      Re: Vortex Breaker09/01/2010 5:41 AM

    Is a vortex breaker required if the pump suction nozzle is to the side (i.e. vertical side) of the vessel ?

    Abdel HalimGalalaGuru

     

    Join Date: Feb 2007Location: Cairo, EgyptPosts: 1746Good Answers: 241

      Re: Vortex Breaker09/01/2010 11:30 AM

    If the suction nozzle located at side, there must be a specific min. head of liquid, and we recommend vortex breaker and/or flat bSee the following site: http://www.gouldspumps.com/pag_0006.html .

     __________________It is better to be defeated on principles, than to win on lies!

    sajidaslamParticipant

    Join Date: Jul 2008Posts: 1

      Re: Vortex Breaker07/26/2011 7:00 AM

    Dear Abdel Halim,

    You always came up with correct and precise answers. can i know your email address. please.

    sajid aslam

    Metallurgical and Materials Engineer

    working in petrofac.

    regards

    CR4 Admin - email address removed

    From the CR4 Rules: Do not post phone numbers or email addresses. The CR4 Admin will delete all phone numbers and email addresses posted in threads or comments. You can share this information via the CR4 internal messaging system.

    phoenix911Guru

     

    Join Date: Aug 2007Posts: 14116Good Answers: 232

      Re: Vortex Breaker03/11/2008 1:42 PM

    As stated there are a number of ways to do it.

    I have also done this with brining operation where there is a high volume pump on a shallow tank or reservoir.

    I included a picture of a sample.

    It basically break it into smaller vortexes so you would not get cavitation to the pump

    Hope you can see it, or I can email it.

    2

    http://cr4.globalspec.com/group/member/1515http://cr4.globalspec.com/group/member/1303http://cr4.globalspec.com/group/member/1033http://cr4.globalspec.com/member/9221/phoenix911http://cr4.globalspec.com/member/9221/phoenix911http://cr4.globalspec.com/faq/cr4ruleshttp://cr4.globalspec.com/member/17934/sajidaslamhttp://www.gouldspumps.com/pag_0006.htmlhttp://cr4.globalspec.com/group/member/291http://cr4.globalspec.com/group/member/80http://cr4.globalspec.com/member/4893/Abdel-Halim-Galalahttp://cr4.globalspec.com/member/4893/Abdel-Halim-Galalahttp://cr4.globalspec.com/member/41111/Azhar-Alihttp://cr4.globalspec.com/thread/43243/Vortex-Problems-in-Pump-Applicationshttp://cr4.globalspec.com/member?u=8679http://cr4.globalspec.com/group/member/291http://cr4.globalspec.com/group/member/80http://cr4.globalspec.com/member/4893/Abdel-Halim-Galalahttp://cr4.globalspec.com/member/4893/Abdel-Halim-Galalahttp://cr4.globalspec.com/member/8679/mbaz-81http://www.eng-tips.com/viewthread.cfm?qid=156148&page=1http://cr4.globalspec.com/group/member/291http://cr4.globalspec.com/group/member/80http://cr4.globalspec.com/member/4893/Abdel-Halim-Galala

  • 8/17/2019 CR4 - Thread_ Vortex Breaker

    3/4

    phoenix911

     __________________phoenix911

    No more Good Answers. Go to first "Almost" Good

    met_3mr84Member

    Join Date: Jan 2008Posts: 8

      Re: Vortex Breaker03/11/2008 3:57 PM

    AS I KNOW , THE VORTEX BREAKER IS USED IN SOME TYPES OF PRESSURE VESSELS, ITS LOCATION IS OPPOSITE THE OUTLET NOZIT IS USED TO BREAK THE VORTEX WAVES STREAMS NEAR THE OUTLESS NOZZLE

    GannetPower-User

     

    Join Date: Mar 2008Location: Baltimore, MDPosts: 150

    Good Answers: 5

      Re: Vortex Breaker03/14/2008 4:39 PM

    I worked on Main Condenser for Steam Powerplants and the hotwell condensate discharge have what we called "baffles" whose primfunction was to prevent swirl in the discharge flow. The baffles were cross "+" plates welded inside of the condensate discharge pipe.

    chaterpilarPower-User

    Join Date: Aug 2007Location: Bhopal IndiaPosts: 234Good Answers: 5

      Re: Vortex Breaker03/30/2008 10:12 AM

    Hello Guest,

    Whenever there is flow of water through a drain pipe, you will notice a swirling effect.

    You might have seen this in sink of your kitchen, or when you are draining the bathtub.

    The same applies to silos or deareators where the suction point at deareator creates

    swirling effect (vortex).

    Now, this is harmful to pump as it traps air and causes cavitation in pump, so to break the swirlin"vortex breaker" is installed at the suction point ( bottom of deareator) ...as shown in the image..13B)

    This does not allow the vortex to form and hence is useful in deareators.

    Hope it is clear.

    Cheers.

     __________________He must be very ignorant as he answers all the questions he is asked. Voltaire

    No more "Almost" Good A

    papasumitMember

      Re: Vortex Breaker10/25/2010 3:46 AM

    You can use the following equation from the ANSI/HI 9.8-1998 "Hydraulic Institute´s Pump Intake Design" that is:S = D + 2.3DFrS is the minimum required submergence to avoid vortex formation.

    Get the IHS Engineering360

    Mechanical ComponentsNewsletter 

    Engineering Newsletter Signup

    Stay up to date on:Products and materials used in mechanical

    assembly, and non-destructive test procedures to

    detect problems.

     

    http://cr4.globalspec.com/member/42616/papasumithttp://cr4.globalspec.com/member/9096/chaterpilarhttp://cr4.globalspec.com/member/9096/chaterpilarhttp://cr4.globalspec.com/group/member/960http://cr4.globalspec.com/group/member/959http://cr4.globalspec.com/group/member/756http://cr4.globalspec.com/member/14303/Gannethttp://cr4.globalspec.com/member/14303/Gannethttp://cr4.globalspec.com/member/13121/met-3mr84

  • 8/17/2019 CR4 - Thread_ Vortex Breaker

    4/4

    In reply t

    Reply to Forum Thread

    Copy to Cli

    Join Date: Oct 2010Location: PunePosts: 5

    D is the nozzle diameter and Fr is the dimensionless Froud number, Fr = V/(gD)**0.5V is the nozzle flow velocity and g the gravitational acceleration.

    or

    Refer to "Pressure Vessel Handbook", Megyesy, Vortex Breaker

     __________________Mechanical Engineer By heart!

    LorenzoParticipant

    Join Date: Sep 2011

    Posts: 1

      Re: Vortex Breaker09/08/2011 11:20 AM

    sorry can you specify wich unit system must be used in formula?Thanks

    14 c

    Bac

    Interested in this topic? By joining CR4 you can "subscribe" tothis discussion and receive notification when new comments are added.

    Join CR4, The Engineer's Place for News and Discussion!

    Comments rated to be Good Answers:

    These comments received enough positive ratings to make them "good answers".

    #3 "Re: Vortex Breaker " by Abdel Halim Galala  on 03/11/2008 12:24 AM (score 2)#4 "Re: Vortex Breaker " by phoenix911  on 03/11/2008 1:42 PM (score 2)

    Comments rated to be "almost" Good Answers:

    Check out these comments that don't yet have enough votes to be "official" good answers and, if you agree with them, rate them!

    #7 "Re: Vortex Breaker " by chaterpilar  on 03/30/2008 10:12 AM (score 1)

    Users who posted comments:

    Abdel Halim Galala  (3); Azhar Ali  (1); chaterpilar  (1); Gannet  (1); Hendrik  (1); Lorenzo  (1); mbaz_81  (1); met_3mr84  (1); papasumit  (1); phoenix911  (1);PWSlack  (1); sajidaslam  (1)

    Previous in Forum: design  Next in Forum: How to Disribute Conditioning Air

    You might be interested in: Compressed Air and Vortex Cooling Tubes, Vortex Flow Meters, Circuit Breakers

    Advertisement

    "Knowledge and human power are synonymous." -- Francis Bacon

    All times are displayed in US/Eastern (EDT) (Register to change time zone)

    © 2016 IHS. All rights reserved. Reproduction in whole or in part without permission is prohibited. The information contained on this site is by users for users and is provided for informpurposes only and does not constitute advice. Any views or opinions expressed by users are personal to them and do not represent the views or opinions of IHS. You should check anyinformation and use your own judgment or seek expert advice before doing or not doing anything on the basis of what you read here. IHS does not verify or warrant the accuracy orcompleteness of any information on this site and, to the extent permitted by law, IHS shall not be liable for any loss, damage or expense incurred by reliance on it or for any dealings yhave with users or other third parties that take place using or facilitated by this site.

     

    Business Email Address

    SIGN UP

    You can change your email preferences at any time.

    Read our full privacy policy.

    Indonesia

    http://www.globalspec.com/SpecSearch/Suppliers/Manufacturing_Process_Equipment/Heat_Transfer_Equipment/Compressed_Air_Vortex_Coolershttp://www.globalspec.com/SpecSearch/Suppliers/Sensors_Transducers_Detectors/Flow_Sensing/Vortex_Flow_Metershttp://www.globalspec.com/Help/Privacyhttp://cr4.globalspec.com/user/registerhttps://googleads.g.doubleclick.net/aclk?sa=L&ai=BNHpa1R_-VtjnEpSSvgSd_aq4Ade_wJ4IAAAAEAEgr_-eHzgAWPfjgv3aAmDpgoCAhA6yARJjcjQuZ2xvYmFsc3BlYy5jb226AQlnZnBfaW1hZ2XIAQLaATFodHRwOi8vZ2xvYmFsc3BlYy5jb20vdGhyZWFkLzE4NzIwL1ZvcnRleC1CcmVha2VywAIC4AIA6gIuLzQyNTAvZW5naW5lZXJpbmczNjAvY3I0L01lY2hhbmljYWxFbmdpbmVlcmluZ_gC9NEekAOwCZgD4AOoAwHIA5kE0ASQTuAEAdIFBRDXuN5rkAYBoAYU2AcB4AcP&num=0&cid=5GgqFfszM6Csq28pTcBjt4hi&sig=AOD64_26xXDbVtn1GyLq9Qz0iur2bkLavQ&client=ca-pub-6035513853108979&adurl=https://engineering.purdue.edu/ProEd/%3Fsource%3Dengineering360&nm=2http://cr4.globalspec.com/rss/rss_use?feedUrl=%2Fforum%2Frss%2Fmechanical%2Dengineeringhttp://www.globalspec.com/SpecSearch/Suppliers/Electrical_Electronic_Components/Electrical_Distribution_Protection_Equipment/Circuit_Breakershttp://www.globalspec.com/SpecSearch/Suppliers/Sensors_Transducers_Detectors/Flow_Sensing/Vortex_Flow_Metershttp://www.globalspec.com/SpecSearch/Suppliers/Manufacturing_Process_Equipment/Heat_Transfer_Equipment/Compressed_Air_Vortex_Coolershttp://cr4.globalspec.com/thread/18724/How-to-Disribute-Conditioning-Airhttp://cr4.globalspec.com/thread/18705/designhttp://cr4.globalspec.com/member/17934/sajidaslamhttp://cr4.globalspec.com/member/4159/PWSlackhttp://cr4.globalspec.com/member/9221/phoenix911http://cr4.globalspec.com/member/42616/papasumithttp://cr4.globalspec.com/member/13121/met-3mr84http://cr4.globalspec.com/member/8679/mbaz-81http://cr4.globalspec.com/member/51572/Lorenzohttp://cr4.globalspec.com/member/4035/Hendrikhttp://cr4.globalspec.com/member/14303/Gannethttp://cr4.globalspec.com/member/9096/chaterpilarhttp://cr4.globalspec.com/member/41111/Azhar-Alihttp://cr4.globalspec.com/member/4893/Abdel-Halim-Galalahttp://cr4.globalspec.com/user/registerhttp://cr4.globalspec.com/member/51572/Lorenzohttp://cr4.globalspec.com/member/42616/papasumithttp://cr4.globalspec.com/edit/newcomment?objectid=18720&objecttype=THREAD&rnd=63209