CR RQPS 300582335 - B - 1 / 10 ·  · 2017-01-122 Fiche contrôle grain equiaxe N°502_S91 7 AQPS...

10
CE DOCUMENT EST LA PROPRIETE EXCLUSIVE DE LA SOCIETE TURBOMECA, IL NE PEUT ETRE UTILISE SANS SON AUTORISATION. THIS DOCUMENT IS THE SOLE PROPERTY OF TURBOMECA AND MAY NOT BE USED WITHOUT ITS EXPRESS AUTHORIZATION. Compte Rendu RQPS_300582335 Version B RQPS Precicast Qualification grain macro et Laüe pour rien RQPS pour rien Langue principale : Français LIENS / Links pour rien DOCUMENTS DE REFERENCE / Reference documents : pour rien Type / Type Référence / Doc Number Désignation / Designation CR_RQPS_300582335 - B <25 mars 2016> - 1 / 10

Transcript of CR RQPS 300582335 - B - 1 / 10 ·  · 2017-01-122 Fiche contrôle grain equiaxe N°502_S91 7 AQPS...

CE DOCUMENT EST LA PROPRIETE EXCLUSIVE DE LA SOCIETE TURBOMECA, IL NE PEUT ETRE UTILISE SANS SON AUTORISATION.THIS DOCUMENT IS THE SOLE PROPERTY OF TURBOMECA AND MAY NOT BE USED WITHOUT ITS EXPRESS AUTHORIZATION.

Compte Rendu RQPS_300582335 Version B

RQPS Precicast Qualification grain macro et Laüe

pour rien

RQPSpour rien

Langue principale : Français

LIENS / Linkspour rien

DOCUMENTS DE REFERENCE / Reference documents :pour rien

Type / Type Référence / Doc Number Désignation / Designation

CR_RQPS_300582335 - B <25 mars 2016> - 1 / 10

Compte Rendu Qualification Procédés Spéciaux

Special Processes Qualification Report

Réf : 300582335 Ind B

Date : 21/03/2016

Nom du Fournisseur Supplier

PRECICAST Code fournisseur

Supplier number MDM502694

Adresse Address

VIA RESIGA 6-6883 NOVAZZANO (TI) - SWITZERLAND

Activité Fournisseur Supplier Activities

FONDERIE

Contact fournisseur Supplier contact

Nom Gaetano Ferrazzano

Fonction Responsable Niveau 3

Adresse email [email protected]

Nature Audit Audit Purpose

Sur site On-site audit

Sur Dossier(DQ) On DQ

Date : 21/03/2016

Evaluation Evaluation

Renouvellement Re-Approval

Qualification initiale Approval

Surveillance Folow up

Autre* Other

*Si Autre préciser : If other detail :

Thème Audit Scope of Audit

Macrographic etch and control of grain on blades - Control of the cristallograhic desorientation on single cristal by Laue method.

Equipe audit & audités Audit staff& auditees

Fonction Title

Nom Name

Safran Fournisseur

Supplier Catégorie de l’auditeur Safran

(1)

Safran auditor level

Responsable de l’audit Camille CASTAING Turboméca Auditeur société

(1) Support Nadcap, Safran, société, en formation /Nadcap support, Safran, society, in progress

Spécification(s) de l’audit Audit Specification

Référentiels techniques Safran Safran Technical Specification

Autres référentiels Other specification

CCT 294, CCT 254, CCT 172, CCT 738, CCT 565

Procédés et n°PS Process and PS n°

Identification des installations Facility identification

Référentiel Technique Technical specifications

Accréditation NADCAP

(2)

Nadcap accreditation Décision

(3)

Si restrictions ou surveillance référence du paragraphe

11.2.2 CCT 565, CCT294, CCT254, CCT172

Qualifié

8.15.3 CCT 294 CCT 738

Qualifié

(2) : A = Accrédité, E = Engagé, R = Refusé / A=Accredited, E=Engaged, R=Refused

(3) : Qualifié, Refusé, Suspendu, Qualifié provisoirement, Qualifié avec restriction(s), Autorisé avec surveillance /Qualified,

Failed, temporary qualified, qualification with technical restriction(s), authorized with enhanced monitoring

Bilan des écarts et recommandations

Majeur(s) : Major

Mineur(s) : Minor

Recommandations : Préventives

Fournisseur Supplier

Représentant Safran Safran representative

Date : Nom : Visa : Date : Nom : Visa :

CR_RQPS_300582335 - B <25 mars 2016> - 2 / 10

Compte Rendu Qualification Procédés Spéciaux

Special Processes Qualification Report

Réf : 300582335 Ind B

Date : 21/03/2016

Produits étudiés pendant l’audit Product aim of the audit

Points Forts Positive points

Points Faibles Weak points

Motivation de la décision Roots of the decision

Precicast is a supplier for Turbomeca. Precicast was audited on-site in 2013 for the macrographic control (on single cristal, DS and equiaxed blades) and controlling of the orientation by Laue method on single crystal blade (RQPS_300582335_A). Precicast has been re-qualified by Snecma in January 2016 for macroetching and inspection. During document audit, Precicast showed reactivity and pertinence in his answers. For macrographic etch and control: the results obtained from master blades show that the modification of the parameters asked by Snecma has no impact on the results of Process. For Laue: There is no change since 2013. Precicast showed reactivity in his answers and for the testing of attack made for this documentary audit.

Pièces Jointes / Attachments :

Observations éventuelles Fournisseurs Supplier Remarks

Supplier Signature ( si observations /if remarks only)

CR_RQPS_300582335 - B <25 mars 2016> - 3 / 10

Compte Rendu Qualification Procédés Spéciaux

Special Processes Qualification Report

Réf : 300582335 Ind B

Date : 21/03/2016

(4) : m = mineur/ minor M = majeur/ major

Eléments analysés Items reviewed

1 Fiche contrôle grain DS200 N°96_S91 6 LAUE Crystallographic Instruction / 0110 S144 ED. 00

2 Fiche contrôle grain equiaxe N°502_S91 7 AQPS n° CP/2016/076-REV00 (qualification Snecma)

3 Baths Control Registration / 02.02.2016 8 Qualification matrix

4 DQ LAUE 9

5 DQ MACRO 10

Tableau des écarts Deviation table N° de l’écart Deviation n° jj N°

Niveau (4)

Level

Procédé Process

Description de l’écart Non Conformance Report Responsible

Responsable Responsible

Délai Time limit

Statut Status

Tableau des Recommandations Préventives table

N° de la recommandation Preventive n°

Procédé Process

Description Description

CR_RQPS_300582335 - B <25 mars 2016> - 4 / 10

Compte Rendu Qualification Procédés Spéciaux

Special Processes Qualification Report

Réf : 300582335 Ind B

Date : 21/03/2016

1) Contexte / Context

Renewal qualification of the following process: - Measurement of crystallographic orientation of single cristal by the Laue method - Grain macrographic control on equiaxed, DS and single cristal blade.

2) Résultats de l’audit système / Results of the System Audit

N/A

3) Résultats de la reconnaissance d’Aptitude / Results of the capability recognition survey

3.1) Examen des moyens / Survey of the facility

Macrographic etch and control Following the audit of Snecma, changes have been made in the RMAC13 etching process - Bath temperature: 60 to 70 ° C becomes 50 to 60 ° C. - Method and rinsing time He was asked Precicast to inform Turbomeca at all future changes in the process. In addition, it is important to perform tests on master blades. After discussion, Precicast realized etch test on master blades with new RMAC13 etch settings. Given the results obtained from master blades, we can say the modification of the parameters has no impact on the results of Process.

DS200 blade_code 0096

DS200 master blade – 7 mars 2007

DS200 master blade – 07.03.2016 (the first production batch processed, after parameters changes made on the Acid Etching Process)

CR_RQPS_300582335 - B <25 mars 2016> - 5 / 10

Compte Rendu Qualification Procédés Spéciaux

Special Processes Qualification Report

Réf : 300582335 Ind B

Date : 21/03/2016

Single cristal blade_code 0110

SX master blade – 14.11.2012

SX master blade – 16.03.2016 (after modification of the etch parameters)

Equiaxe blade_ code 0573

Equiaxes master blade – 09.05.2012

CR_RQPS_300582335 - B <25 mars 2016> - 6 / 10

Compte Rendu Qualification Procédés Spéciaux

Special Processes Qualification Report

Réf : 300582335 Ind B

Date : 21/03/2016

Equiaxes master blade – 15.03.2016 (after modification of the etch parameters)

LAUE

There is no change since 2013.

3.2) Examen documentaire / Survey of the documentation

For qualification renewal, the following documents were studied: - The macrographic and Laue DQ - Periodic monitoring form baths - Instruction of equiaxed and DS grain control - Instruction Sheet Laue

3.3) Examen de la qualification des opérateurs / Survey of the qualification of the personnel

Operator qualification matrix for each control.

3.4) Examen de la mise en œuvre du procédé / Survey of the implementation of the process

No on-site audit. See RQPS of 2013.

3.5) Examen des essais croisés (partie spécifique aux essais laboratoires)

N/A

CR_RQPS_300582335 - B <25 mars 2016> - 7 / 10

Compte Rendu Qualification Procédés Spéciaux

Special Processes Qualification Report

Réf : 300582335 Ind B

Date : 21/03/2016

Annexe1_RQPS_300582335_B

CR_RQPS_300582335 - B <25 mars 2016> - 8 / 10

Attestation de Qualification des Procédés Spéciaux

Special Processes Qualification Certificate

N° AQPS : 300582335_B

Code fournisseur: Supplier number MDM502694

Société SAFRAN émettrice : Issuing SAFRAN company TURBOMECA

Prononce la qualification du fournisseur suivant la GRP- 0087 Approval on the supplier qualification according to GRP-0087

PRECICAST SA Via Resiga, 6 - 6883 NOVAZZANO

Pour les procédés spéciaux suivants, les domaines sont précisés page suivante For the following special processes, refer to next page for scope definition

SAFRAN process n°

Procédés Processes

Référentiel technique Technical specification

Statut Status

Restrictions techniques Technical limitations

Fin de validité Expiration date

11.2.2

Chaîne d’attaque macrographique pour pales monocristallines, DS200, Equiaxe / macroetching line for blade (single cristal, DS200, equiaxe)

CCT 565 CCT 294, CCT254, CCT172

QUALIFICATION Qualification pour l’attaque macrographique sur pales monocristallines, DS200 et equiaxe / macroetching for blade (single cristal, DS200, equiaxe)

30/11/2018

8.15.3

Contrôle de l’orientation des pales monocristallines par méthode LAUE / Control of cristallographic desorientation on single cristal by Laue method

CCT 294 CCT 738

QUALIFICATION Monocristaux / Single cristal

30/11/2018

N° de rapport

Report n° Observations

Remarks

RQPS n° 300582335_B After document review, exchange with PRECICAST and etch test on master blade with new parameters requested by SNECMA: no contra-indication for the qualification renewal. No change of equipment or person for laue control since last audit.

Auditeur/Responsable de la Qualification

Auditor/Qualification Leader

Date Nom / Name Signature

21/03/2016 CASTAING Camille

CR_RQPS_300582335 - B <25 mars 2016> - 9 / 10

Domaine de Qualification des Procédés Spéciaux

Special Processes Qualification Scope

Identification des installations Facilities identification

Caractéristiques des installations Facilities features

Matériaux Materials

Domaine d’utilisation Operating scope

Commentaires Comments

Chaîne attaque RMAC13 / RMAC13 Etch line

Nickel base Pales monocristallines, pales DS200, pales

equiaxes / Single cristal Blade, DS200 blade, equiaxe blade

Chaîne attaque anodique / Anodic Etch line

Nickel base Pales monocristallines / Single cristal Blade

Système LAUE Philips PW 3830/00

Nickel base Pales monocristallines / Single cristal Blade

CR_RQPS_300582335 - B <25 mars 2016> - 10 / 10