CPLR

2
Compound Air-Plasma Lightning Rejection System CPLR or Compound Air Plasma Lightning Rejection System is the first system ever invented in the world to extinguish the lightning strikes. Invented by the one of the top 60 scientist in China, Professor Dr Kun Sheng Wang had received several silver and gold awards in international invention fairs for this invention. The principles of the CPLR is to neutralized the downleader streamer of the lightning cloud by generating highly density plasma ion and released it to the air. Thus, will eliminate the early formation of the lightning strikes and protect the vicinities. How CPLR Works? How CPLR Works? Standard Lightning protection system either conventional or unconventional early streamer emission (ESE) will divert the high energy lightning to the ground. This will protect the building structure as well as the human life inside the building and also prevent fire. But, no matter how effective your lightning protection system, the equipment is still subject to secondary effect of lightning or “transient overvoltage” or commonly known as “surges”. By implementing the CPLR, the area under the protection radius will never experienced direct lightning strikes or surges since the formation of lightning is neutralize through the emission of the high density plasma into the air. Why CPLR? Why CPLR? From left to right : Early lightning detector, PLC control unit and air plasma generator. PLC control unit Control unit display The early lightning detector will detect electrical field strength of lightning cloud within the radius of 20km. Then the detector will triggers the control unit to automatically starts the air-plasma generator. The generator will release the ions when the lightning cloud is within 3km radius. The released positive charges will neutralize the not so intensified downward leader from the cloud. Meanwhile the released negative charges will neutralize the natural positive charges on the ground. This process innovatively diffuse the formation of lightning.

description

Nonconventional LPS

Transcript of CPLR

  • Front (size: A4)

    Compound Air-PlasmaLightning Rejection System

    CPLR or Compound Air Plasma Lightning Rejection

    System is the first system ever invented in the world to

    extinguish the lightning strikes. Invented by the one of

    the top 60 scientist in China, Professor Dr Kun Sheng

    Wang had received several silver and gold awards in

    international invention fairs for this invention. The

    principles of the CPLR is to neutralized the downleader

    streamer of the lightning cloud by generating highly

    density plasma ion and released it to the air. Thus, will

    eliminate the early formation of the lightning strikes and

    protect the vicinities.

    How CPLR Works?How CPLR Works?

    Standard Lightning protection system either conventional or unconventional early streamer emission (ESE) will divert the high energy lightning to the ground. This will protect the building structure as well as the human life inside the building and also prevent fire. But, no matter how effective your lightning protection system, the equipment is still subject to secondary effect of lightning or transient overvoltage or commonly known as surges.

    By implementing the CPLR, the area under the protection radius will never experienced direct lightning strikes or surges since the formation of lightning is neutralize through the emission of the high density plasma into the air.

    Why CPLR?Why CPLR?

    From left to right : Early lightning detector, PLC control unit and air plasma generator.

    PLC control unit Control unit display

    The early lightning detector will detect electrical field strength of lightning cloud within the radius of 20km. Then the detector will triggers the control unit to automatically starts the air-plasma generator. The generator will release the ions when the lightning cloud is within 3km radius. The released positive charges will neutralize the not so intensified downward leader from the cloud. Meanwhile the released negative charges will neutralize the natural positive charges on the ground.

    This process innovatively diffuse the formation of lightning.

  • Back

    CPLR is mostly suitable for solar farm, military radar station, ammunition depot and

    highly inflammable area.

    In solar farm for instance, it is worthy to install CPLR because of the millions initial

    investment incurred . A typical 2MWp system is easily cost more than RM15millions

    and per month sun yield is approximately RM200,000. Imagine if the system strikes by

    lightning and fails for weeks, losses will be millions!

    Geographically, Malaysia is located in one of the world's highest lightning density

    regions. Solar farm especially, requires direct sunlight for optimum output. The PV

    panels are openly at risk to lightning strikes. Investors should seriously consider CPLR

    as an effective solutions to protect their investment. Beside that, CPLR will also save

    the cost of replacing the equipment damaged by lightning.

    CPLR is the best choice to provide the best insurance for your investment.

    Typical Application of CPLRTypical Application of CPLR

    * H : height of the system installed

    Radius of protection area

    Angle of protection

    Technical specicationsModel Number CPLR - 1000G - PKT

    Power Supply 220Vac,~ 50/60Hz, Single phase

    Rated power 1000 Watt

    Energy Consumption 1 kWh

    Plasma density 10 N/m315

    Radius of protection 8 x Height , H

    Angle of protection 83

    Early Lightning detector radius 20 km

    Early Lightning detector electrical Field Strength 0.1 - 50 kV/m (factory preset is 20)

    Reaction time for alarm 10 sec

    Ambient temperature - 40C ~ +50C

    Rated duty cycle 100%

    Weight 80 kg Dimensions

    Length of each lightning tube 6500 mm

    Diameter of shielding ball 750 mm

    R

    H

    Innovative Engineering by:Pekat Engineering Sdn Bhd.5&6, Teknologi Kubik, No 6, Jalan Teknologi 3/4, Taman Sains Selangor 1,Kota Damansara, 47810 Petaling Jaya, Selangor Darul Ehsan

    Tel: (603) 2300 8010 Fax: (603) 9235 1077Website : www.pekat.com.my

    CPLR Brochure FrontCPLR Brochure Back