CPA Micarta Based Rahul Sharma / Bill Sands. The present design shown in this document is based on...
-
Upload
peter-greene -
Category
Documents
-
view
214 -
download
0
Transcript of CPA Micarta Based Rahul Sharma / Bill Sands. The present design shown in this document is based on...
![Page 1: CPA Micarta Based Rahul Sharma / Bill Sands. The present design shown in this document is based on the use of Micarta as the base material this will likely.](https://reader035.fdocuments.in/reader035/viewer/2022062519/5697bf9c1a28abf838c93777/html5/thumbnails/1.jpg)
CPA Micarta Based
Rahul Sharma / Bill Sands
![Page 2: CPA Micarta Based Rahul Sharma / Bill Sands. The present design shown in this document is based on the use of Micarta as the base material this will likely.](https://reader035.fdocuments.in/reader035/viewer/2022062519/5697bf9c1a28abf838c93777/html5/thumbnails/2.jpg)
The present design shown in this document is based on the use of Micarta as the base material this will likely change the design will work with G-10 or other materials with minor changes due to material strengths.
![Page 3: CPA Micarta Based Rahul Sharma / Bill Sands. The present design shown in this document is based on the use of Micarta as the base material this will likely.](https://reader035.fdocuments.in/reader035/viewer/2022062519/5697bf9c1a28abf838c93777/html5/thumbnails/3.jpg)
24 Panel 3 section Micarta CPA Weight ~ 1400 lbs.12 parallel plate sections
![Page 4: CPA Micarta Based Rahul Sharma / Bill Sands. The present design shown in this document is based on the use of Micarta as the base material this will likely.](https://reader035.fdocuments.in/reader035/viewer/2022062519/5697bf9c1a28abf838c93777/html5/thumbnails/4.jpg)
CPA Overall Dimensions
![Page 5: CPA Micarta Based Rahul Sharma / Bill Sands. The present design shown in this document is based on the use of Micarta as the base material this will likely.](https://reader035.fdocuments.in/reader035/viewer/2022062519/5697bf9c1a28abf838c93777/html5/thumbnails/5.jpg)
Main Hanger G-106 Pcs. Required
![Page 6: CPA Micarta Based Rahul Sharma / Bill Sands. The present design shown in this document is based on the use of Micarta as the base material this will likely.](https://reader035.fdocuments.in/reader035/viewer/2022062519/5697bf9c1a28abf838c93777/html5/thumbnails/6.jpg)
Main Hanger Dimensions
![Page 7: CPA Micarta Based Rahul Sharma / Bill Sands. The present design shown in this document is based on the use of Micarta as the base material this will likely.](https://reader035.fdocuments.in/reader035/viewer/2022062519/5697bf9c1a28abf838c93777/html5/thumbnails/7.jpg)
Main hanger internal stainless steel reinforcement
![Page 8: CPA Micarta Based Rahul Sharma / Bill Sands. The present design shown in this document is based on the use of Micarta as the base material this will likely.](https://reader035.fdocuments.in/reader035/viewer/2022062519/5697bf9c1a28abf838c93777/html5/thumbnails/8.jpg)
Tubes are fitted inside one and other and fastened with FH screws the horizontal tubes have stainless steel reinforcement tubes at the joints as they are subjected to loading
![Page 9: CPA Micarta Based Rahul Sharma / Bill Sands. The present design shown in this document is based on the use of Micarta as the base material this will likely.](https://reader035.fdocuments.in/reader035/viewer/2022062519/5697bf9c1a28abf838c93777/html5/thumbnails/9.jpg)
Each vertical section consists of 2 tubes and 3 stainless steel hangers to support a column of 4 parallel plate sections
![Page 10: CPA Micarta Based Rahul Sharma / Bill Sands. The present design shown in this document is based on the use of Micarta as the base material this will likely.](https://reader035.fdocuments.in/reader035/viewer/2022062519/5697bf9c1a28abf838c93777/html5/thumbnails/10.jpg)
Parallel plates are connected to 3” wide strips with tapped holes to connect the panels
![Page 11: CPA Micarta Based Rahul Sharma / Bill Sands. The present design shown in this document is based on the use of Micarta as the base material this will likely.](https://reader035.fdocuments.in/reader035/viewer/2022062519/5697bf9c1a28abf838c93777/html5/thumbnails/11.jpg)
Example of a 2 plane middle section weight ~100 lbs.
![Page 12: CPA Micarta Based Rahul Sharma / Bill Sands. The present design shown in this document is based on the use of Micarta as the base material this will likely.](https://reader035.fdocuments.in/reader035/viewer/2022062519/5697bf9c1a28abf838c93777/html5/thumbnails/12.jpg)
Center joint connecting middle section to the end sections
![Page 13: CPA Micarta Based Rahul Sharma / Bill Sands. The present design shown in this document is based on the use of Micarta as the base material this will likely.](https://reader035.fdocuments.in/reader035/viewer/2022062519/5697bf9c1a28abf838c93777/html5/thumbnails/13.jpg)
Center joint has the vertical connector dropped in after the tube is slide as do the other vertical joints this joint also brings HV from one section to the other
![Page 14: CPA Micarta Based Rahul Sharma / Bill Sands. The present design shown in this document is based on the use of Micarta as the base material this will likely.](https://reader035.fdocuments.in/reader035/viewer/2022062519/5697bf9c1a28abf838c93777/html5/thumbnails/14.jpg)
½” tapped pins connect the vertical sections
![Page 15: CPA Micarta Based Rahul Sharma / Bill Sands. The present design shown in this document is based on the use of Micarta as the base material this will likely.](https://reader035.fdocuments.in/reader035/viewer/2022062519/5697bf9c1a28abf838c93777/html5/thumbnails/15.jpg)
Shear pin connection pin and oversized head screws
![Page 16: CPA Micarta Based Rahul Sharma / Bill Sands. The present design shown in this document is based on the use of Micarta as the base material this will likely.](https://reader035.fdocuments.in/reader035/viewer/2022062519/5697bf9c1a28abf838c93777/html5/thumbnails/16.jpg)
![Page 17: CPA Micarta Based Rahul Sharma / Bill Sands. The present design shown in this document is based on the use of Micarta as the base material this will likely.](https://reader035.fdocuments.in/reader035/viewer/2022062519/5697bf9c1a28abf838c93777/html5/thumbnails/17.jpg)
Cryo testing of the Micarta and G-10 demonstrate that the tensile strengths in both materials do rather well in a cryo state
![Page 18: CPA Micarta Based Rahul Sharma / Bill Sands. The present design shown in this document is based on the use of Micarta as the base material this will likely.](https://reader035.fdocuments.in/reader035/viewer/2022062519/5697bf9c1a28abf838c93777/html5/thumbnails/18.jpg)
Stainless steel elbow to vertical tube connection
Horizontal tube to elbow connection with column pin connector
![Page 19: CPA Micarta Based Rahul Sharma / Bill Sands. The present design shown in this document is based on the use of Micarta as the base material this will likely.](https://reader035.fdocuments.in/reader035/viewer/2022062519/5697bf9c1a28abf838c93777/html5/thumbnails/19.jpg)
Swivel tee for HV connection
![Page 20: CPA Micarta Based Rahul Sharma / Bill Sands. The present design shown in this document is based on the use of Micarta as the base material this will likely.](https://reader035.fdocuments.in/reader035/viewer/2022062519/5697bf9c1a28abf838c93777/html5/thumbnails/20.jpg)
Slots cut into top and bottom panels to allow liquid argon flow between panels
![Page 21: CPA Micarta Based Rahul Sharma / Bill Sands. The present design shown in this document is based on the use of Micarta as the base material this will likely.](https://reader035.fdocuments.in/reader035/viewer/2022062519/5697bf9c1a28abf838c93777/html5/thumbnails/21.jpg)
Conclusion
• This document demonstrates that this is a viable design for construction of the CPA the design will likely need to be tweaked with a change in material.