CORTLAND COUNTY E-911 COMMUNICATIONS CENTER - PHASE 2
Transcript of CORTLAND COUNTY E-911 COMMUNICATIONS CENTER - PHASE 2
LOCATION MAP
358 West Jefferson StreetSyracuse, NY 13202p 315 | 671-2400f 315 | 671-7891www.kingarch.com
BARTON & LOGUIDICE, D.P.C.443 Electronics ParkwayLiverpool, NY 13088p 315 | 457-5200www.bartonandloguidice.com
CO
RTL
AN
D C
OU
NTY
E-91
1 CO
MM
UN
ICATI
ON
S C
ENTE
R -
PHASE
2
Issued for Bid 08/23/2019
19-1
1-66
94K
ING
+KIN
G P
RO
JEC
T N
UM
BE
R:
ARCHITECT'S CERTIFICATIONTHE UNDERSIGNED CERTIFIES THAT TO THE BEST OF THEIR KNOWLEDGE, INFORMATION, AND BELIEF, THE PLANS AND SPECIFICATIONS ARE IN ACCORDANCE WITH APPLICABLE REQUIREMENTS OF THE NEW YORK STATE UNIFORM FIRE PREVENTION AND BUILDING CODE, THE NEW YORK STATE ENERGY CONSERVATION CONSTRUCTION CODE, AND THE CONSTRUCTION STANDARDS OF THE EDUCATION DEPARTMENT.
DRAWING INDEX
COVERPAGE
ENVIRONMENTALX0.02 ROOF ASBESTOS REMOVAL PLAN
ARCHITECTURALA1.12 ROOF PLAN AND DETAILS
22 W
EST
CO
UR
T ST
REE
TC
OR
TLA
ND
, NY
130
45
CORTLAND COUNTYE-911 COMMUNICATIONS CENTER - PHASE 222 WEST COURT STREETCORTLAND, NY 13045
MARK DESCRIPTION DATE
Issued for Bid08/23/2019DRAWING DATE:
DIGITAL REPRODUCTIONS OF THESE DRAWINGS SHALL NOT BE POSTED TO WEB SITES WITHOUT THE DIRECT WRITTEN PERMISSION OF THE ARCHITECT.IT IS A VIOLATION OF THE STATE EDUCATION LAW FOR ANY PERSON, UNLESS UNDER THE DIRECTION OF A LICENSED ARCHITECT TO ALTER THIS DOCUMENT IN ANY WAY. ALTERATIONS MUST HAVE THE SEAL AFFIXED ALONG WITH THE DESCRIPTION OF THE ALTERATION AND SIGNATURE AND DATE. COPYRIGHT ©.
CO
RTL
AN
D C
OU
NTY
E-
911
CO
MM
UN
ICAT
ION
S C
EN
TER
-P
HA
SE
222
WE
ST
CO
UR
T S
TRE
ET
CO
RTL
AN
D, N
Y 1
3045
19-11-6694
KING + KING PROJ. NO.:
X0.02
SCALE:DRAWING TITLE:
Sheet Scale
ROOF ASBESTOS REMOVAL PLAN
A
B
C
D
E
1 2 3 4 5 6
MARK DESCRIPTIONDATE
Issued for Review
DRAWING DATE:
DIGITAL REPRODUCTIONS OF THESE
DRAWINGS SHALL NOT BE POSTED TO WEB
SITES WITHOUT THE DIRECT WRITTEN
PERMISSION OF THE ARCHITECT.
IT IS A VIOLATION OF THE STATE EDUCATION
LAW FOR ANY PERSON, UNLESS UNDER THE
DIRECTION OF A LICENSED ARCHITECT TO
ALTER THIS DOCUMENT IN ANY WAY.
ALTERATIONS MUST HAVE THE SEAL AFFIXED
ALONG WITH THE DESCRIPTION OF THE
ALTERATION AND SIGNATURE AND DATE.
COPYRIGHT ©.
CO
RT
LA
ND
C
OU
NT
Y
E-9
11
C
OM
MU
NIC
AT
IO
NS
C
EN
TE
R
22 W
ES
T C
OU
RT
S
TR
EE
T
CO
RT
LA
ND
, N
Y 13045
19-11-6694KING + KING PROJ. NO.:
SCALE:
DRAWING TITLE:
A
B
C
D
E
1 2 3 4 5 6
MATERIAL REMOVAL SCHEDULE
7/11/2019
X0.02
NOT TO SCALE
ROOF ASBESTOS
REMOVAL PLAN
MARK DESCRIPTIONDATE
Issued for Review
DRAWING DATE:
DIGITAL REPRODUCTIONS OF THESE
DRAWINGS SHALL NOT BE POSTED TO WEB
SITES WITHOUT THE DIRECT WRITTEN
PERMISSION OF THE ARCHITECT.
IT IS A VIOLATION OF THE STATE EDUCATION
LAW FOR ANY PERSON, UNLESS UNDER THE
DIRECTION OF A LICENSED ARCHITECT TO
ALTER THIS DOCUMENT IN ANY WAY.
ALTERATIONS MUST HAVE THE SEAL AFFIXED
ALONG WITH THE DESCRIPTION OF THE
ALTERATION AND SIGNATURE AND DATE.
COPYRIGHT ©.
CO
RT
LA
ND
C
OU
NT
Y
E-9
11
C
OM
MU
NIC
AT
IO
NS
C
EN
TE
R
22 W
ES
T C
OU
RT
S
TR
EE
T
CO
RT
LA
ND
, N
Y 13045
19-11-6694KING + KING PROJ. NO.:
SCALE:
DRAWING TITLE:
A
B
C
D
E
1 2 3 4 5 6
MATERIAL REMOVAL SCHEDULE
7/11/2019
X0.02
NOT TO SCALE
ROOF ASBESTOS
REMOVAL PLAN
MARK DESCRIPTION DATE
Issued for Bid08/23/2019DRAWING DATE:
DIGITAL REPRODUCTIONS OF THESE DRAWINGS SHALL NOT BE POSTED TO WEB SITES WITHOUT THE DIRECT WRITTEN PERMISSION OF THE ARCHITECT.IT IS A VIOLATION OF THE STATE EDUCATION LAW FOR ANY PERSON, UNLESS UNDER THE DIRECTION OF A LICENSED ARCHITECT TO ALTER THIS DOCUMENT IN ANY WAY. ALTERATIONS MUST HAVE THE SEAL AFFIXED ALONG WITH THE DESCRIPTION OF THE ALTERATION AND SIGNATURE AND DATE. COPYRIGHT ©.
CO
RTL
AN
D C
OU
NTY
E-
911
CO
MM
UN
ICAT
ION
S C
EN
TER
-P
HA
SE
222
WE
ST
CO
UR
T S
TRE
ET
CO
RTL
AN
D, N
Y 1
3045
19-11-6694
KING + KING PROJ. NO.:
A1.12
SCALE:DRAWING TITLE:
Varies
ROOF PLAN AND DETAILS
A
B
C
D
E
1 2 3 4 5 6
ROOF PLANScale: 1/4" = 1'-0"
A5
A1.12
C1A1.12
B3A1.12
B1A1.12
B1A1.12
C1A1.12
SLOPE = 1/4:12 MIN.SLOPE = 1/4:12 MIN.
SLO
PE
= 1/
4:12
MIN
.
EX
ISTI
NG
SLO
PE
D
STR
UC
TUR
E-
THIC
KN
ES
S O
F N
EW
R
OO
FIN
G S
YS
TEM
TO
R
EM
AIN
CO
NST
ANT
TAPERED RIGID INSULATION, R-30 MIN.
E1A1.12
E1A1.12
E1A1.12
E1A1.12
REMOVE EXISTING ROOF SYSTEM IN ITS ENTIRETY DOWN TO EXISTING METAL DECK, INCLUDING ROOF EDGE/ PARAPET FLASHING
A3A1.12
B1A1.12
SIM.
C3A1.12
RAISED PARAPET WITH NEW METAL COPING, TYP.
EXISTING CANOPY ROOF WITH FASCIA CLADDING, ROOF SYSTEM, SCUPPERS AND DOWNSPOUTS.
SLOPE =1/4:12 MIN.
PATCH AND REPAIR ROOF OR WALL ANCHOR PENETRATIONS CAUSED BY PREVIOUSLY EXISTING ELECTRICAL CONDUIT.
INFILL AND PATCH EXISTING ROOF PENETRATIONS FROM PREVIOUSLY EXISTING ROOFTOP EQUIPMENT, ENTIRE ROOF TYP.
SLOPE =1/4:12 MIN.
E3A1.12
TAPERED RIGID INSULATION, SLOPED TO SCUPPER, TYP. MIN. SLOPE = 1/4:12
SCUPPER TOCONDUCTOR HEAD AND
DOWNSPOUT.DOWNSPOUT FASTENEDTO BUILDING MASONRYWALL AND TERMINATED
AT GRADE WITH 45DEGREE OUTLET AND
CONCRETE SPLASHBLOCK, TYP.
REMOVE EXISTING ROOF SYSTEM IN ITS ENTIRETYDOWN TO EXISTING WOOD FRAMING, INCLUDING
ROOD EDGE/ PARAPET FLASHING, PERIMETERWOOD BLOCKING, AND FRONT FASCIA PANELS.
OVERFLOW ROOF DRAIN
PRIMARY ROOF DRAIN
15" X 15" PIPE CURB ASSEMBLY WITH INTEGRAL 16” HIGH CURB. FINAL LOCATIONS TO BE CONFIRMED BY OWNER.
REMOVE EXISTINGPVC SLEEVE IN ITS
ENTIRETY ANDPATCH DECK
12'-0"O.C.
42'-6
"
O.C
.
6'-0
"
O.C
.
15'-0"
O.C.E4
A1.12
FULLY ADHERED EPDMMEMBRANE
1/2" COVER BOARD
POLY-ISO RIGIDINSULATION, R=30 MIN.
EXISTINGMETAL
DECKING
FASTEN EPDM FLASHING TO EPDM ROOF MEMBRANE, PER MFG. INSTRUCTION
5/8" SUBSTRATE BOARD
CONTINUOUS VAPORBARRIER
TYPICAL ROOFING SYSTEMScale: 1 1/2" = 1'-0"
A1
A1.12
FORMED FLASHING UMBRELLA WITH HEMMED EDGE
STAINLESS STEEL DRAW BAND
EDGE SEALANT
EDGE SEALANT
EPDM FLASHING MEMBRANE SET IN BONDING ADHESIVE
FIELD FLASHED VENT PIPEVENT PIPE EXTENSION
PIPES UP TO 6" DIA. AND WHERETOP OF PIPE IS LESS THAN 8"
ABOVE ROOF SURFACE
PIPES OVER 6" DIAMETER WHERE PIPE BOOT CAN NOT BE SLIPPED OVER TOP OF PIPE OR PIPES EXCEEDING 6'-0" IN HEIGHT
PRESSURE TREATED 2x WOODBLOCKING, TYPICAL. SHIM ASREQUIRED TO MATCH HEIGHT
OF INSULATION
PRE-MANUFACTRED RUBBERBOOT SET IN BONDING
ADHESIVE
SEAM TAPE(TYP.)
EDGE SEALANT
PIPE SLEEVE & CLAMPINGRINGS
STAINLESS STEELCLAMPING RING
VENT PIPE - USE PIPEEXTENSION WHERE REQUIRED
FASTEN ROOF MEMBRANE TOBLOCKING WITH SEAM
FASTENING PLATE
TYPICAL PIPE VENTScale: 1 1/2" = 1'-0"
E1
A1.12
EXTEND ROOFMEMBRANE AND
FLASHING UNDERCLAMPING RING &
SEAL W/ WATER CUTOFF MASTIC, TYP TAPERED EDGE
STRIP, TYP.
DRAIN STRAINER
SEAL MEMBRANE FLASHING AT EDGE, TYP.
BATT INSULATION WITHINVAPOR JACKET, TYP.
DECK CLAMP, TYPICAL
ROOF LEADER, TYPICAL.PLUMB INTO EXISTING DRAIN
LINE THROUGH EXTERIORWALL ON REAR OF BUILDING.
CLAMPING RING2" MINIMUM
INSULATION ATDRAIN, TYP.
SLOPE SLOPE
SUMP TO DRAIN- 2'-0" MIN.SUMP TO DRAIN- 2'-0" MIN.
FLEXIBLE BELLOW CONNECTION, TYPICAL
TEMPORARY CONNECTION TO EXISTING ROOF LEADER UNTIL FUTURE PHASE
TYPICAL ROOF DRAINScale: 1 1/2" = 1'-0"
C1
A1.12
EPDM ROOFING SYSTEM, WRAP OVER AND FASTEN TO PARAPET
POLY-ISO RIGID INSULATION, R-30 MIN.
1/2" COVER BOARD
VAPOR BARRIER
5/8" SUBSTRATE BOARD
EXISTING METAL PAN
PRE-MANUF. METAL ROOF EDGE FLASHING W/ DRIP EDGE
STRIP-IN MEMBRANE
FASTEN USING PRE-PUNCHED HOLES AT 6" O.C. MIN, USING 1 1/4" GALV. RING SHANK ROOFING NAILS
CONT 24 GA. GALV. STEEL WATER DAM
FASTEN PRE-PUNCHED WATER DAM 12" O.C. PER MANUF. RECOMMENDATIONS
VAR
IES
AP
PR
OX.
14"
@ R
AIS
ED
PAR
APETHOLD HIGH
0"POINT
CONT. LAP SEALANT, TYP.
2X WOOD BLOCKING
4" WIDE SPRING CLIP @ 4'-0" O.C.
REMOVE EXISTING STUCCO VENEER AS REQUIRED TO SEAT NEW METAL ROOF EDGE FLASHING
CAULK JOINT
TYPICAL ROOF EDGE DETAILScale: 3" = 1'-0"
B1
A1.12
POLY-ISO RIGID INSULATION, R-30 MIN.
1/2" COVER BOARD
VAPOR BARRIER, EXTEND AND WRAP OVER PARAPET
5/8" SUBSTRATE BOARD
EXISTING METAL DECKING
GENERAL NOTES:
1. INSTALL METAL WORK TO MANUFACTURER'S REQUIREMENTS OR SMACNA RECOMMENDATIONS. IF SHOP FABRICATED METAL EDGE IS USED IT MUST MEET ANSI/SPRI ES-1 OR AN FM STANDARD.
2. LAP SEALANT IS REQUIRED ALONG UPSLOPE EDGE OF FLASHING WHEN ROOF SLOPE IS 1" PER FOOT OR GREATER.
3. WOOD NAILER MUST BE INSTALLED TO MEET APPLICABLE BUILDING CODES OR 200 LBS PER LINEAR FOOT MINIMUM IN ANY GIVEN DIRECTION.
4. FLANGE OF METAL MUST BE FULLY SUPPORTED BY WOOD AND TERMINATED AT LEAST 1/2" FROM EDGE OF WOOD.
5. REFER TO DRAWING X0.02 AND SPECIFICATIONS FOR ASBESTOS REMEDIATION REQUIRED AS PART OF EXISTING ROOF REMOVAL.
PRE-MANUF. METAL ROOF EDGE FLASHING W/ DRIP EDGE
STRIP-IN MEMBRANE
FASTEN USING PRE-PUNCHED HOLES AT 6" O.C. MIN, USING 1 1/4" GALV. RING SHANK ROOFING NAILS
CONT 24 GA. GALV. STEEL WATER DAM
FASTEN PRE-PUNCHED WATER DAM 12" O.C. PER MANUF. RECOMMENDATIONS
2X WOOD BLOCKING
4" WIDE SPRING CLIP @ 4'-0" O.C.
REMOVE EXISTING STUCCO VENEER AS REQUIRED TO SEAT NEW METAL ROOF EDGE FLASHING
CAULK JOINT
HOLD HIGH
ROOF EDGE DETAIL @ HIGH POINTScale: 3" = 1'-0"
B3
A1.12
2" MIN
.
4"
SHOP FABRICATED .050" METAL CAP WITH DRIP EDGE, ALL 4 SIDES TYP
EXISTING MASONRY CHIMNEY
FULLY ADHERED EPDM MEMBRANE, LAP PER MFR. RECOMMENDATIONS, WRAP OVER TOP OF CHIMNEY & FASTEN TO WOOD BLOCKING
+/- 2'-0"
V.I.F.
2X WOOD BLOCKING AT PERIMETER, WRAP ROOF MEMBRANE OVER TOP
ROOFING AT EXISTING CHIMNEYScale: 1 1/2" = 1'-0"
A3
A1.12
METAL COPING W/ DRIPEDGE- FINISH TO MATCH
ROOF COPING
EPDM FLASHING STRIP
EXISTING BRICK MASONRY WALL
EXISTING CEMENT BOARD SOFFIT W/ EXISTING METAL SOFFIT TO BE REPLACE AT FUTURE PHASE
10"
6"
2 PC, REGLET-TYPE, 16 OZ. LEAD COATED COPPER COUNTER FLASHING
RAKE OUT EXG BRICK JT 1” DEEP AND PROVIDE REGLET W/ LEAD WEDGES
TERM BAR W/ FASTENERS & NEOPRENE WASHERS @ 12” O.C. MAX, PROVIDE SEALANT @ TOP
NEW 1/2" P.T. PLYWOOD SHEATHING OVER EXISTING CANOPY FRAMING
SHOP FABRICATED 2-PIECE .050" METAL FASCIA, SEE C4/ A1.12
DOUBLE 2X 6 WOOD PARAPET, 3 SIDES OF CANOPY TYP. SECURE TO EACH EXISTING CANOPY FRAMING MEMBER W/ MIN. (4) 3" WOOD SCREWS
EXISTING 2X CANOPY FRAMING
CANOPY SECTIONScale: 1 1/2" = 1'-0"
C3
A1.12
GENERAL NOTES:
1. INSTALL METAL WORK TO MANUFACTURER'S REQUIREMENTS OR SMACNA RECOMMENDATIONS. IF SHOP FABRICATED METAL EDGE IS USED IT MUST MEET ANSI/SPRI ES-1 OR AN FM STANDARD.
2. LAP SEALANT IS REQUIRED ALONG UPSLOPE EDGE OF FLASHING WHEN ROOF SLOPE IS 1" PER FOOT OR GREATER.
3. WOOD NAILER MUST BE INSTALLED TO MEET APPLICABLE BUILDING CODES OR 200 LBS PER LINEAR FOOT MINIMUM IN ANY GIVEN DIRECTION.
4. FLANGE OF METAL MUST BE FULLY SUPPORTED BY WOOD AND TERMINATED AT LEAST 1/2" FROM EDGE OF WOOD.
5. REFER TO DRAWING X0.02 AND SPECIFICATIONS FOR ASBESTOS REMEDIATION REQUIRED AS PART OF EXISTING ROOF REMOVAL.
STRIP-IN MEMBRANE
4" WIDE SPRING CLIP @ 4'-0" O.C.
CONTINUOUS BEAD OF LAP SEALANT
SHOP FABRICATED .050" METAL COPING W/DRIP EDGE- FINISH TO MATCH ROOF COPING
6"X 6"X 7" METAL CONDUCTOR HEAD, CONNECTED TO DOWNSPOUT
DRIP EDGE, BOTH SIDES TYP.
PARAPET BEYOND
1 2"M
IN.
4" X 4" METAL DOWNSPOUTCONT. SEALANT
FULLY ADHERED EPDM MEMBRANE
7"
6"
4"
2X PT WOOD FRAMING, WRAP WITHCONT. AIR & WATER VAPOR BARRIER
METAL RETURN ON UNDERSIDE, CONT. SEALANT ON LONG EDGES
EXISTING CEMENT BOARD SOFFIT W/ EXISTING METAL SOFFIT TO BE REPLACED AT FUTURE PHASE
SLOPE TO DRAIN
TAPERED RIGID INSULATION, SLOPE = 1/4: 12
NEW 1/2" P.T. PLYWOOD SHEATHING OVER EXISTING CANOPY FRAMING
2"
10"
6"
SHOP FABRICATED 2-PIECE .050" METAL FASCIA W/ DRIP EDGE
CANOPY SECTIONScale: 1 1/2" = 1'-0"
E3
A1.12
2015 NY STATE ENERGY CODE SUMMARY
CORTLAND COUNTY: CLIMATE ZONE 5AROOF INSULATION REQURED ABOVE DECK: R- 30 C.I. MIN.ROOF INSULATION PROVIDED ABOVE DECK: R- 30 C.I. MIN.
10"
6"
SEALANT, TYP
.050” FASCIA EXTENDER TO MATCH FASCIA W/ 20 GA GALV. CLEAT
DRIP EDGE, TYP
DRIP EDGE, TYP
.050” SHOP FABRICATED ALUM FASCIA W/ CONCEALED SPLICE PLATE
FULLY ADHERED EPDM MEMBRANE, WRAP OVER CURB
FASCIA DETAILScale: 3" = 1'-0"
C4
A1.12
EPDM FLASHINGSCREW ANCHOR PLATE @ 12" O.C.
RIGID INSULATION, R-30 MIN.
LAP SEALANT (TYP)
4" M
IN
EPDM FLASHING SET IN BONDING ADHESIVE, EXTEND UPAND OVER & SECURE TO ROOF CURB BLOCKING
EXISTING ROOF DECK
EPDM LAP SPLICE1'-0" MIN
2x6 FIRE TREATED WOOD BLOCKING, SHIM ASREQ'D TO MATCH HEIGHT OF EXG. ROOF SYSTEM, COORD. LOCATION WITH MECH. CONTRACTOR
PREFAB. INSUL. PIPE CURB ASSEMBLY,
SILICONE SEALANT
TYP. PIPE CURBScale: 1 1/2" = 1'-0"
E4
A1.12