CopperMeterResettersTo Set 5/8", 5/8" x 3/4", 3/4", 1", 11⁄2" & 2" Water Meters
11/12
11-122
Table of Contents
Page
Meter Resetters - 5/8", 5/8" x 3/4", 3/4", & 1" Horizontal Inlet and Outlet
Series 710
General Information ....................................................4-5
Series 717
Low Rise Style ............................................................... 6
Series 718
Horizontal Style ............................................................. 7
Series 719
Vertical Style - Meter Thread x Meter Thread .................. 8
Series 768
Horizontal "F" Style - Flexible ........................................ 9
Series 758
Crab Style Tandem .......................................................10Inverted Tandem ..........................................................10Inline Tandem ..............................................................11
Page
Meter Resetters - 11⁄2" & 2"Vertical Inlet and Outlet
Series 718
No Bypass ...................................................................12With Bypass .................................................................13
AccessoriesGaskets .......................................................................14Meter Bushings / Adapters .........................................14Meter Dimensions .......................................................14Tandem Options ...........................................................15Sectional View .............................................................15
Page 6
710 Series
717-204XDCASeries 717 with Backflow Preventer and Thermal Expansion Tank (Tank must be purchased separately). 717-204XDCC
Series 717 used to retrofit existing high rise meter pit and standard meter resetter with backflow preventer and pressure relief valve.
Page 4-5 Page 7
718 Series
717 SeriesPage 6
11-12 3
A.Y. McDonald Mfg. Co. Resetters offer a wide variety of options for resetting your current water meter to various heights and locations. Resetters are used where the meter is already installed and the service lines are in place, but the meter needs to be relocated above or next to the current line. A.Y. McDonald Mfg. Co. resetters provide you with an array of variations that will see you through any relocation project.
Common resetter installations are shown below. You can customize your resetter solution on the pages within, or contact our factory professionals to help you through.
BEFORE AFTER
General Information
- Brass materials meet or exceed AWWA C-800 (latest revision)
- Copper tubing has a 13⁄16" O.D. for 5/8", 5/8" x 3/4" or 3/4" meter resetters, 11⁄8" O.D. for 1" meter resetters, 15⁄8" for 11⁄2" meter resetters and 21⁄8" for 2" meter resetters.
- Solder is no-lead.
- EPDM rubber gaskets are furnished as standard. Contact factory for fiber or leather gaskets.
- All meter resetters are factory tested air under water at 85 PSIG.
- Brass support bar is standard on 18" and higher meter resetters.
- Meter resetter heights over 24" available on special order.
- All meter swivel nuts have wire seal hole.
- Lockwing ball style meter valves are standard.
- Meter swivel nuts with meter support saddle are standard, except where noted.
- All copper meter resetters can be supplied with a test valve on the outlet tubing.
- For dual check backflow valves, see catalog section 13.
- Brace eye hole accepts 1/2" iron pipe or PVC for 5/8", 5/8" x 3/4" and 3/4" meters and 1" vertical meter resetters.
- Brace eye hole accepts 3/4" iron pipe or PVC for 1", horizontal meter resetters.
- Brace eye hole accepts 1" iron pipe or PVC for 11⁄2" & 2", horizontal meter resetters.
The A.Y. McDonald Meter Resetter is a unique and patented product designed to easily retrofit existing meter installations to include a dual check backflow preventer, or pressure relief valve. This is accomplished without the high risk of cutting into old service lines, or the expensive process of digging up and replacing existing meter boxes or pits. This retrofitting can be easily performed in even the most confined meter boxes.
ASSE listed dual checkPatent No. 4,691,727
Meter Dimensions
AfterNOTE: Meter box sold separately
Meter Threads
Cast Brass Base
Meter Threads
Dual Check Backflow Preventer (optional)
Copper Tubing
Available for 5/8", 5/8" x 3/4", or 3/4" meters
BeforeNOTE: Meter box sold separately
Cast Brass Meter Nuts with Rubber Gaskets
METER SIZE 5/8" 5/8" x 3/4" 3/4"
A-Meter Threads 3/4" 1" 1" B-Lay Length 71⁄2" 71⁄2" 9" A.Y. McDonald Spacing* 713⁄16" 713⁄16" 95⁄16"
11-124
Copper Meter Resetters
0 5 10 15 20 25 30 0 5 10 15 20 0 2.5 5 7.5 10
30
25
20
15
10
5
0
20
15
10
5
0
20
15
10
5
0
3/4" Series 710 without backflow
5/8" x 3/4" Series 710 without backflow
3/4" Series 710 with backflow
5/8" x 3/4" Series 710 with backflow
5/8" Series 710 without backflow
5/8" Series 710 with backflow
WATE
R F
LOW
(G
allons
Per
Min
ute
)
WATE
R F
LOW
(G
allons
Per
Min
ute
)
WATE
R F
LOW
(G
allons
Per
Min
ute
)
PRESSURE DROP (Pounds per Square Inch) PRESSURE DROP (Pounds per Square Inch)PRESSURE DROP (Pounds per Square Inch)
THERMAL EXPANSION WARNING - Creating a “closed” condition in a hot water system with the installation of a non-return barrier (such as a Check Valve or Backflow Preventer between the system piping and the public supply) can result in extreme pressure rises caused by thermal expansion and/or water hammer. This thermal expansion can damage piping, valves, and other components in the system. The installation of a pressure relief device or thermal expansion tank can avoid possible damages.
710 SERIES
Pressure Loss Data
Series Style Meter Size Meter Height Meter Connections Bottom Bar 1/2" FNPT Space Tube Offset Options Bottom Bar Tap
710 – = Standard For crossed sized meter setsA = 5/8"B = 5/8" x 3/4"C = 3/4"R = Right offset
1 = 5/8" 2 = 5/8" x 3/4" 3 = 3/4"
3"6" 7"12"
OPTIONS- Resetters with cross-over meter sizes are available, contact factory.* For angle ball valves integral to resetter, contact factory.- Not all combinations available, contact factory with your requirements.
- MOST METER RESETTERS ARE MADE TO ORDER AND ARE NOT RETURNABLE.
- Please verify with the factory that the model number you have configured is available and meets your requirements.
11-12 5
Copper Meter Resetters
– = No tapA = Tap inlet, no plugB = Tap outlet, no plugD = Tap outlet, with 125# PRVE = Tap inlet, with 175# PRVF = Tap outlet, with 175# PRVG = Tap inlet, with plugH = Tap outlet, with plugL = Tap inlet, with 125# PRV(Inlet is city side, outlet is house side)
X72--NN061-
See above side view
as required
710
Model 710-103NN - - X72
Offset Left Standard
Model 710-106NN - -
Side View72° Left Offset
StandardSide View
– = No optionC = Dual check on inletH = Dual check on outletJ = Adapter idler on outlet (sized to fit meter)U = UFR on outlet (Integral)
Approx.6”
Approx. 3”
A BTap Locations
Inlet Inlet
A BTap Locations
*
N = No valve (meter nut only without saddle)Q = Lockwing ball valve (without saddle)
Dual Check Backflow Preventer (Inlet side)
711-3AN 34 For 5/8" meter
711-3AN 44 For 5/8" x 3/4" and 3/4" meter Inlet: Male meter thread Outlet: Female meter thread (union)
Dual Check Backflow Preventer (Outlet side)
711-3NA 43 For 5/8" meter
711-3NA 44 For 5/8" x 3/4" and 3/4" meter Inlet: Female meter thread (union) Outlet: Male meter thread Pressure Relief Valve
710P125 125 lb. rated
710P175 175 lb. rated - 1/2" MNPT thread
Plug
73208 1/2”
710J11 Meter Adapter Idler (New Style) 3 3/4" long with gasket, adapts basic 710 Series unit (less backflow preventer) to 71⁄2" lay length - 5/8" meter
710J22 Meter Adapter Idler 3 3/4" long with gasket, adapts basic 710 Series unit (less backflow preventer) to 7" lay length - 5/8" x 3/4" meter
710J23 Meter Adapter Idler 11⁄2" long with gasket. Use with 710 Series unit and backflow preventer to increase lay length - 3/4" meter
710 SERIES
Ordering Options Separately
Low Rise Style Resetter90º tubing to bottom bar is standard, contact factory for other options.
The A.Y. McDonald 717 Series low rise resetter allows you to reset a meter incorporating an inlet or outlet shut off valve or check valve. It also offers several options for taps to incorporate pressure relief valves or sampling valves before or after the meter. Ninety degree tubing to bottom bar is standard, other options are available (contact factory for information).
OPTIONS- Not all combinations available, contact factory with your requirements.
- MOST METER RESETTERS ARE MADE TO ORDER AND ARE NOT RETURNABLE.
- Please verify with the factory that the model number you have configured is available and meets your requirements.
11-126
Copper Meter Resetters
Series Style Meter Size Meter Height Meter Connections Bottom Bar FNPT Optional Offset Tap Location Bottom Bar Tap717 – = Standard
For crossed sized meter setsA = 5/8"B = 5/8" x 3/4"C = 3/4"
Offset Left:U = 5/8"V = 5/8" x 3/4"W = 3/4"X = Offset Left
1 = 5/8" 2 = 5/8"x 3/4" 3 = 3/4" 4 = 1"
4"6"
- for 1" meter only. For special
heights, contact factory.
– = No tapA = 1/2" FNPT - no plugB = 1/2" FNPT - with brass square head plugC = 1/2" FNPT - 125# PRVD = 3/4" FNPT - no plug (only 1" resetter)E = 3/4" FNPT - with brass square head plug (only 1" resetter)
--DW042-717
– = No TapA = Inlet LeftB = Outlet Left C = Outlet TopD = Outlet Bottom
C = Angle single check valve on outletD = Angle dual check valve on outlet (ASSE 1024) W = Angle lockwing ball valveX = No valve - meter nut onlyFor other special meter connections, contact factory.
Series 717 is typically viewed from the inlet side, and is fabricated as a “right offset” (see photo above and at right). This is critical when considering tap locations. Left offset is available upon special request - contact factory.
Tap A
Inlet(city side)
Outlet(house side)
Tap D - (top)
Tap C
(bottom)
Tap B
Tap A
Inlet(city side)
Tap C - (top)Tap D
(bottom)
Tap B
Left Offset Right Offset
Outlet(house side)
INLETMeter Thread
90º Offset Right View Standard
OUTLETMeter Thread
Model 717-204WD - -
45 = 45º 60 = 60º 180 = 180º
717 SERIES
Horizontal Style ResetterMinimum 10" height on 1" resetters, or 12" on 1" resetter with angle dual check.
The A.Y. McDonald 718 horizontal resetter allows you to reset a meter incorporating an inlet or outlet shut off valve or check valve while offering several height options. It also offers several options for taps to incorporate pressure relief valves or sampling valves before or after the meter. Depending on valve configurations, minimum heights may vary.
OPTIONS- Not all combinations available, contact factory with your requirements.
- MOST METER RESETTERS ARE MADE TO ORDER AND ARE NOT RETURNABLE.
- Please verify with the factory that the model number you have configured is available and meets your requirements.
11-12 7
Copper Meter Resetters
Series Style Meter Size Meter Height Meter Connections Bottom Bar FNPT Tap Location Bottom Bar Tap718 – = Standard
For crossed sized meter setsA = 5/8"B = 5/8" x 3/4"C = 3/4"
1 = 5/8" 2 = 5/8"x 3/4" 3 = 3/4" 4 = 1"
07"09"10"12"15"18"21"24"
For special heights, contact factory.
Blank = No TapA = 1/2" FNPT - no plugB = 1/2" FNPT - with brass square head plugC = 1/2" FNPT - 125# PRVD = 1/2" FNPT - 175# PRV
--XW072-718
Blank = No TapA = 1/2" FNPT inletB = 1/2" FNPT outlet
C = Angle single check valve on outletD = Angle dual check valve on outlet (ASSE 1024) W = Angle lockwing ball valveX = No valve - meter nut onlyFor other special meter connections, contact factory.
Model 718-207WX - -
INLETMeter Thread
OUTLETMeter Thread
For Tandem Seriesess
Example 758-207WXTandem resetters are supplied with adapters and “S” tube. Please specify device length and threads when ordering.
758
SeriesHorizontalTandem Setter
718 SERIES
Vertical Style Resetter - Meter Thread x Meter Thread
The A.Y. McDonald 719 vertical to horizontal resetter allows you to reset a meter currently in a vertical position to a horizontal position incorporating an inlet or outlet shut off valve or check valve. It also offers several height options and several options for taps to incorporate pressure relief valves or sampling valves before or after the meter.
- Meter swivel nuts are less saddle
OPTIONS- Not all combinations available, contact factory with your requirements.
- MOST METER RESETTERS ARE MADE TO ORDER AND ARE NOT RETURNABLE.
- Please verify with the factory that the model number you have configured is available and meets your requirements.
11-128
Copper Meter Resetters
Model 719-2
Series Style Meter Size Meter Height Meter Connections Bottom Bar FNPT Tap Location Bottom Bar Tap718 – = Standard
For crossed sized meter setsA = 5/8"B = 5/8" x 3/4"C = 3/4"
1 = 5/8" 2 = 5/8" x 3/4" 3 = 3/4" 4 = 1"
– = StandardFor special heights,
contact factory.
Blank = No TapA = 1/2" FNPT - no plugB = 1/2" FNPT - with brass square head plugC = 1/2" FNPT - 125# PRVD = 1/2" FNPT - 175# PRV
--NQ--2-719
Blank = No TapA = 1/2" FNPT inletB = 1/2" FNPT outlet
A = Angle single check valve on outletF = Angle dual check valve on outlet (ASSE 1024) Q = Angle lockwing ball valveN = No valve - meter nut onlyFor other special meter connections, contact factory.
719 SERIES
Horizontal "F" Style Flexible ResetterMinimum 15" height on 1" resetters. Resetters with cross-over meter sizes are available, contact factory.
The A.Y. McDonald 768 horizontal “F Style” (Flexible) resetter allows you to reset a meter incorporating an inlet or outlet shut off valve or check valve. It also offers several height options and flexibility if existing set is not aligned correctly.
OPTIONS- Not all combinations available, contact factory with your requirements.
- MOST METER RESETTERS ARE MADE TO ORDER AND ARE NOT RETURNABLE.
- Please verify with the factory that the model number you have configured is available and meets your requirements.
11-12 9
Copper Meter Resetters
Series Style Meter Size Meter Height Inlet Outlet Meter Connections
768 – = Standard For crossed sized meter setsA = 5/8"B = 5/8" x 3/4"C = 3/4"
1 = 5/8" 2 = 5/8" x 3/4" 3 = 3/4" 4 = 1"
12"15"18"21"24"
For special heights, contact
factory.
XW121-768
C = Angle single check valve on outlet (Not availabe on 1")D = Angle dual check valve on outlet (ASSE 1024) W = Angle lockwing ball valveX = No valve - meter nut onlyFor other special meter connections, contact factory.
Model 768-112WX
For Tandem Seriesess
Example 761-112WXTandem resetters are supplied with adapters and “S” tube. Please specify device length and threads when ordering.
761
SeriesHorizontalTandem Setter
INLETMeter Thread
OUTLETMeter Thread
768 SERIES
Crab Style Tandem ResetterMade to set two 71⁄2" meter thread x meter thread devices.The A.Y. McDonald 758 tandem resetter allows you to reset a meter and a device in one low profile compact setting.
- Meter swivel nuts are less saddle
For installing a regulator and meter in an existing setting and there is little room above 2" rise from original meter height. The A.Y. McDonald 758 inverted tandem resetter allows you to reset a meter and a device with minimal rise as long as there is room below the existing meter.- Meter swivel nuts are less saddle
OPTIONS- Not all combinations available, contact factory with your requirements.
- MOST METER RESETTERS ARE MADE TO ORDER AND ARE NOT RETURNABLE.
- Please verify with the factory that the model number you have configured is available and meets your requirements.
11-1210
Copper Meter Resetters
Series Style Meter Size Meter Height Meter Connections Blank Space Crab Style
Series Style Meter Size Meter Height Meter Connections Blank Space Inverted Style
758Tandem
758Tandem
– = Standard
– = Standard
2 = 5/8" x 3/4" 3 = 3/4" 4 = 1"
1 = 5/8"2 = 5/8" x 3/4" 3 = 3/4"
For special heights, contact factory.
For special heights, contact factory.
X419
X406
N
N
N
N
--
02
2
2
-
-
758
758
N = No valve - meter nut onlyFor other special meter connections, contact factory.
N = No valve - meter nut onlyFor other special meter connections, contact factory.
Model 758-2--NN X419
Model 758-202NN X406
758 SERIES
Inverted Tandem
Meter swivel nuts are less saddle.
Inline Tandem ResetterThe A.Y. McDonald 758 inline tandem re-setter with additional options for shut off or check valves plumbed into the tubing to accept inline, a meter and a pressure regulating device. Please supply device length and end connection configuration when ordering.
- Resetters include 74620 meter coupling and 74619 adapter and gaskets.- Meter swivel nuts are less saddle
OPTIONS- Not all combinations available, contact factory with your requirements.
- MOST METER RESETTERS ARE MADE TO ORDER AND ARE NOT RETURNABLE.
- Please verify with the factory that the model number you have configured is available and meets your requirements.
11-12 11
Copper Meter Resetters
Series Style Meter Size Meter Height Meter Connections Blank Space Flange to Flange Spread 758 – = Standard 1 = 5/8"
2 = 5/8" x 3/4" 3 = 3/4" 4 = 1"
07"09"10"12"15"18"21"24"
For special heights, contact factory.
X15.81NQ072-758
A = Angle single check valve on outletF = Angle dual check valve on outlet (ASSE 1024) Q = Angle lockwing ball valveN = No valve - meter nut onlyFor other special meter connections, contact factory.
Model 758-207QN X15.81
INLETMeter Thread
OUTLETMeter Thread
758 SERIES
OPTIONS- Not all combinations available, contact factory with your requirements.
- MOST METER RESETTERS ARE MADE TO ORDER AND ARE NOT RETURNABLE.
- Please verify with the factory that the model number you have configured is available and meets your requirements.
11-1212
Copper Meter Resetters
Horizontal Style Resetters 11⁄2" & 2" - No Bypass1" Copper cross tube is standard for no by-pass setters.
The A.Y. McDonald 718 11⁄2" and 2” oval flanged horizontal resetter allows you to reset a meter incorporating an inlet or outlet shut off valve or check valve while offering several height options. It also offers bypass options and several options for taps to incorporate pressure relief valves or sampling valves before or after the meter. Depending on valve configurations, minimum heights may vary. Brass eye holes accept 1" iron pipe or 1" PVC.
Series Style Meter Size Meter Height Inlet Outlet Meter Connections
718 – = Standard No Bypass
6 = 11⁄2" 7 = 2"
15"18"21"24"
For special heights, contact
factory.Minimum height may apply based on configuration
of setter.
DW186-718
D = Angle dual check valve E = Angle dual check valve with 1" tap in cap with 1" NPT plug assemblyF = Angle dual check valve with 11⁄2" tap in cap with 11⁄2" NPT plug assemblyG = Angle dual check valve with 2" tap in cap with 2" NPT plug assemblyN = Flanged elbowT = Flanged tee with 2" plug in top of tee for accessW = Angle lockwing ball valve
Model 718-618WD
For Tandem Series
Example 758-618WDTandem resetters are supplied with 610M adapters and “S” tube. Please specify device length and threads when ordering.
758
SeriesTandem Setter
eries
xampple 758-618WD
es
INLETMeter Flange
OUTLETMeter Flange
718 SERIES
Lower heights may be available - contact factory.
OPTIONS- Not all combinations available, contact factory with your requirements.
- MOST METER RESETTERS ARE MADE TO ORDER AND ARE NOT RETURNABLE.
- Please verify with the factory that the model number you have configured is available and meets your requirements.
11-12 13
Copper Meter Resetters
Horizontal Style Resetters 11⁄2" & 2" With Bypass
The A.Y. McDonald 718 11⁄2" and 2" oval flanged horizontal resetter allows you to reset a meter incorporating an inlet or outlet shut off valve or check valve while offering several height options. It also offers bypass options and several options for taps to incorporate pressure relief valves or sampling valves before or after the meter. Depending on valve configurations, minimum heights may vary.
- Brass eye holes accept 1" iron pipe or 1" PVC- 2" Meter flanges have slotted bolt holes to fit 11⁄2" or 2" meters- Two drop in flange gaskets furnished.- Two meter support brackets furnished.- 1¼" bypass includes a 1" x 1" x 11⁄4" ball valve.- Resetter with bypass requires a check valve or ball valve on outlet- Cross sized resetters available, contact factory.
Series Bypass Meter Size Meter Height Inlet Outlet Meter Connections
718 6 = 11⁄2" 7 = 2"
12"15"18"21"24"
For special heights, contact
factory.Minimum height may apply based on configuration
of setter.
DW186B718
D = Angle dual check valve E = Angle dual check valve with 1" tap in cap with 1" NPT plug assemblyF = Angle dual check valve with 11⁄2" tap in cap with 11⁄2" NPT plug assemblyG = Angle dual check valve with 2" tap in cap with 2" NPT plug assemblyN = Flanged elbowT = Flanged tee with 2" plug in top of tee for accessW = Angle lockwing ball valve
B = Low bypass R = High Offset
Model 718B618WD
For Tandem Series
Example 758-618WDTandem resetters are supplied with 610M adapters and “S” tube. Please specify device length and threads when ordering.
758
SeriesTandem Setter
610M758--618WD
li d i h 6
INLETMeter Flange
OUTLETMeter Flange
B = Low Bypass
6.50”
Setter Height
R = High Ofset Bypass
61⁄2” to right of meter
718 SERIES
11-1214
Copper Meter Resetters
*Allows for meter and two gaskets.
Note: A.Y. McDonald uses the above standards for typical meter applications. If your application is special or in question, you should always measure the meter as shown above.
Other meter lay lengths must be specified. An additional 3/8" is added to top spacing to allow for gaskets: Standard 2" top spacing = 173⁄8".
Oval Flange Meter Size 5/8" 5/8" x 3/4" 3/4" 1" 11⁄2" 2"
A-Meter Threads 3/4" 1" 1" 11⁄4" 11⁄2" 2" B-Lay Length 71⁄2" 71⁄2" 9" 103⁄4" 13" 17" A.Y. McDonald Spacing* 713⁄16" 713⁄16" 95⁄16" 113⁄32" 13.38" 17.38"
2" Meter Flanges have slotted bolt holes to fit 11⁄2" or 2" meters.
Two drop in flange gaskets furnished.
Two meter support brackets furnished.
Gaskets
10J12 - Converts 5/8" meter spud to 5/8" x 3/4" meter spud - two pieces required per meter
10J12KIT - Converts 5/8" meter spud to 5/8" x 3/4" meter spud - two pieces per bag
10J45 - Converts 1" meter spud to 11⁄4" meter spud - two pieces required per meter
Changes thread size only
Meter Bushings
Meter Dimensions
METER MODEL DESCRIPTION SIZE
18-G1 5/8" Rubber 5/8" 18-G1F 5/8" Fiber 5/8" 18-G1L 5/8" Waxed Leather 5/8"
18-G2 3/4" Rubber 5/8" x 3/4" or 3/4" 18-G2F 3/4" Fiber 5/8" x 3/4" or 3/4" 18-G2L 3/4" Waxed Leather 5/8" x 3/4" or 3/4"
18-G4 1" Rubber 1" 18-G4F 1" Fiber 1" 18-G4L 1" Waxed Leather 1"
METER MODEL DESCRIPTION SIZE
18-G6 11⁄2" Flange-Rubber 11⁄2" 18-G7 2" Flange-Rubber 2"
4620G 11⁄2" Round-Rubber 11⁄2" 4620G 2" Round-Rubber 2"
Converts meter size and laying length
710J13 - Converts 5/8" meter to 3/4" meter - two pieces required per meter
710J13KIT - Converts 5/8" meter to 3/4" meter - two pieces per kit
710J14 - Converts 5/8" meter to 1" meter - two pieces required per meter
710J14KIT - Converts 5/8" meter to 1" meter - two pieces per kit
710J23 - Converts 5/8" x 3/4" meter to 3/4" meter - one piece required per meter
710J24 - Converts 5/8" x 3/4" meter to 1" meter - two pieces required per meter
710J24KIT - Converts 5/8" x 3/4" meter to 1" meter - two pieces per kit
710J34 - Converts 3/4" meter to 1" meter - two pieces required per meter
710J34KIT - Converts 3/4" meter to 1" meter - two pieces per kit
710J46 - Converts 1" meter to 11⁄2" flanged meter size and length - two pieces required per meter
710J46KIT - Converts 1" meter to 11⁄2" flanged meter size and length - two pieces per kit
710J47 - Converts 1" meter to 2" flanged meter size and length two pieces required per meter
710J47KIT - Converts 1" meter to 2" flanged meter size and length two pieces per kit
710J67 - Converts 11⁄2" flanged meter to 2" flanged meter size and length - two pieces required per meter - two bolts included
710J67KIT - Converts 11⁄2" flanged meter to 2" flanged meter size and length - two pieces per kit - four bolts included
710J67DH - Converts 11⁄2" flanged meter to 2" flanged meter size and length - two pieces required per meter Slotted holes for 11⁄2" or 2" meters - does not include bolts and nuts
710J77DHX2 X1.75 - Converts 2" x 15.25" flanged meter to 2" x 17" flanged meter size and length -one piece required per meter. Slotted holes for 11⁄2" or 2" meters - does not include bolts and nuts
6121 - Meter support bracket - 11⁄2" and 2"
Meter Adapters
11-12 15
Copper Meter Resetters
All A.Y. McDonald tandem copper setters are designed to provide the user with the option of placing an auxiliary device in addition to a water meter in a space as small as 18" in diameter (see Table I). The auxiliary device could be a pressure regulator, pressure relief valve, backflow preventer, etc. Table I shows typical lay lengths available for these devices. Other lengths can be provided. Contact our customer service department for details.
- Standard centerline spread for 5/8", 5/8" x 3/4", 3/4" meters is 7". 1" meter is 9".
- Tandem meter setter “S” bar (4619S-size) and brass adapters (74619-size) come as standard when ordering tandem resetters, but are also available separately (see below). Contact factory.
- Resetters with cross-over meter sizes are available, contact factory.
4619S 5/8" - for use with 5/8" meter tandem4619S 5/8" x 3/4" - for use with 5/8" x 3/4" meter tandem4619S 3/4" - for use with 3/4" meter tandemAbove items for use with 4"-5" device
4619S 1 - for use with 1" meter tandemAbove item for use with 5"-6" device
74619 5/8" - (5/8" meter x 3/4" NPT)74619 3/4" - (5/8" x 3/4" or 3/4" meter x 3/4" NPT)74619 1" - (1" meter x 1" NPT)
Two pieces required per device
7"9"
Spread for 5/8", 5/8"x 3/4" and 3/4" MetersSpread for 1" Meters
Note: Special length cross tubes and inverted tandem cross tubes are available, contact factory.
Tandem "S" Bar "S" Bar Adapter
TABLE I Device Minimum Meter Size Length Recommended (FNPT x FNPT) Inside Pit Diameter
5/8" 4" to 5" 18" 5/8" x 3/4" 4" to 5" 18" 3/4" 4" to 5" 20" 1" 5" to 6" 21"
Tandem Options
Sectional View
Angle Meter Valve Ball Style
Test Valve in Tubing
Angle Dual Poppet Check Valve
Copper Tube Flange
Single Poppet Check Valve
Meter Threads
Double wall flange thickness
ASSE 1024
More than a brand. We’re a family. aymcdonald.com 1-800-292-2737 [email protected]
A.Y. McDonald Mfg. Co. is a leading manufacturer of Waterworks Brass, Plumbing Valves,
Pumps and Water Systems, and High Pressure Gas Valves and Meter Bars. The Company has
distinguished itself with a proud tradition of quality and reliability since its founding in 1856.
The mission of A.Y. McDonald Mfg. Co., in the words of our founder, is “to make good products
and sell them honestly.” We, the stockholders and employees, accomplish this by extending
the McDonald family culture through excellent customer service and by focusing on our
customers’ needs.
11/12
WARNING: It is unlawful in CALIFORNIA & VERMONT (effective 1/1/2010); MARYLAND (effective 1/1/2012); LOUISIANA (effective 1/1/2013) and the UNITED STATES OF AMERICA (effective 1/4/2014) to use any product in the installation or repair of any public water system or any plumbing in a facility or system that provides water for human consumption if the wetted surface
area of the product has a weighted average lead content greater than 0.25%. This prohibition does not extend to service saddles used in California, Louisiana or under USA Public Law 111-380.