Copeland R410A Scroll Compressor for Process Chiller

4
R-410A Copeland Scroll compressors for process chiller applications

Transcript of Copeland R410A Scroll Compressor for Process Chiller

Page 1: Copeland R410A Scroll Compressor for Process Chiller

R-410A Copeland Scroll™ compressorsfor process chiller applications

2007ECT-159 R1.indd 12007ECT-159 R1.indd 1 4/27/2012 2:32:30 PM4/27/2012 2:32:30 PM

Page 2: Copeland R410A Scroll Compressor for Process Chiller

R-410A and other R-22 alternatives for process chiller refrigeration applicationsThe phaseout of hydrochlorofluorocarbon (HCFC) refriger-

ants brought dramatic change to the global HVAC industry.

Fueled by a worldwide demand for sustainable design and

environmental concern, the move to new nonchlorine

hydrofluorocarbon (HFC) refrigerants give equipment

manufacturers a chance to incorporate new technologies

that provide better value for customers.

For your customers, R-410A means:• Reduced maintenance expenses

• The most efficient systems for improved cost control

• Lower energy bills

For your business, R-410A means:• Offering your customers the most efficient systems

• Saving on projected costs

• Meeting tomorrow’s tough new energy and

environmental restrictions today

• Avoiding the potential losses in capacity and energy

efficiency of drop-in refrigerant replacements

Our extensive offering of R-410A Copeland Scroll™

compressors ranges from 1.5 to 30 HP. Emerson Climate

Technologies also provides other components that work

with high efficiency R-410A systems, including Emerson™

valves, controls and system protectors for high-pressure

applications.

Process chillers are among the hardest working refrigeration

systems built. Most plants rely on exact temperature fluids

to control manufacturing processes. Industrial process

cooling loads are severely cyclic, ranging from 0% to 100%.

Hot gas bypass has been traditionally used to vary the load

on the system evaporator. Today Emerson Climate

Technologies offers more efficient modulation alternatives

to hot gas bypass - Copeland Scroll Digital™ and Copeland

Scroll UltraTech™ compressors.

Spread idea to carry the cover look and feel throughout the brochure

We’re ready. Are you?Emerson Climate Technologies has developed the broadest, most efficient R-410A scroll compressor lineup in the world, including those for process chiller applications.

R-410A is the leading choice to replace R-22 in air conditioning. Its proven success in air conditioning applications and the similarity of operating conditions for process chiller and air conditioning applications makes R-410A a suitable choice for process chiller applications.

2007ECT-159 R1.indd 22007ECT-159 R1.indd 2 4/27/2012 2:32:55 PM4/27/2012 2:32:55 PM

Page 3: Copeland R410A Scroll Compressor for Process Chiller

Better reliability for your hard-earned reputationField experience with millions of installations worldwide has proven conclusively that robust Copeland Scroll™ R-410A compressors are more reliable in even the harshest environments. When it comes to your reputation, go with the best choice, the preferred choice: Copeland Scroll compressors.

For more information visit CopelandScroll.com.

A comparison with R-22R-410A R-134a R-407C

Ozone Depletion Zero Zero Zero

System Compactness

Better Worse Same

Capacity Higher Lower Lower

System Efficiency

Slightly Higher Equal Lower

Compressor Efficiency

Lower Equal Slightly Higher

Pressures Higher Lower Same

TEWI Better Equal Worse

Applications HT MT/HT MT/HT

POE Lubricants

Required Required Required

Engineering Redesign Effort

Higher Higher Med

R-410A is the best but not the only choice for R-22 replacement. As an alternative to R-410A, R-407C Copeland Scroll compressors are also available for

our customers who prefer other solutions.

Modulation options highlights

Copeland Scroll Digital compressors

• Capacity range from 10 to 100%

• Reduced power consumption – up to 30% more effi-cient than using hot gas bypass

• Longer cycle times to reduce wear and improve hu-midity control

• Simple, variable modulation, for precise temperature control within 0.50°F

Copeland Scroll UltraTech compressors

• Two-step scroll capacity (67%, 100%)

• R-410A ready

2007ECT-159 R1.indd 32007ECT-159 R1.indd 3 4/27/2012 2:32:59 PM4/27/2012 2:32:59 PM

Page 4: Copeland R410A Scroll Compressor for Process Chiller

EmersonClimate.com2007ECT-159 R1 (4/12) Emerson, Copeland, Copeland Scroll and UltraTech are trademarks of Emerson Electric Co. or one of its affiliated companies. ©2012 Emerson Climate Technologies, Inc. All rights reserved. Printed in the USA.

R-410A Copeland Scroll™ modelsSingle Tandems

Capacity (HP)

ModelCapacity

(HP)Model

Capacity (HP)

ModelCapacity

(HP)Model

1.7 ZP20K5E 4.5 ZP54K5E 7 ZPT88K5E 25 ZPU302KCE1.9 ZP21K5E 4.8 ZP57K5E 8 ZPT98K5E 26 ZPT308KCE

2 ZP24K5E 5 ZP61K5E 9 ZPT108K5E 27 ZPU319KCE2.1 ZP25K5E 5.5 ZP67KCE 9.5 ZPT114KCE 28 ZPU336KCE2.3 ZP28K5E 6 ZP72KCE 10 ZPT122KCE 30 ZPT364KCE2.4 ZP29K5E 7 ZP83KCE 11 ZPT134KCE 35 ZPU417KCE2.6 ZP31K5E 7.5 ZP91KC3 12 ZPT144KCE 40 ZPT470KCE2.8 ZP34K5E 9 ZP103KCE 14 ZPT166KCE 50 ZPT590KCE

3 ZP36K5E 10 ZP120KCE 15 ZPT182KCE 55 ZPU680KCE3.2 ZP38K5E 12 ZP137KCE 18 ZPT206KCE 64 ZPT770KCE3.3 ZP39K5E 13 ZP154KCE 19 ZPU223KCE3.5 ZP42K5E 15 ZP182KCE 20 ZPT240KCE3.7 ZP44K5E 20 ZP235KCE 21 ZPU240KCE

4 ZP49K5E 25 ZP295KCE 22 ZPU257KCE4.3 ZP51K5E 30 ZP385KCE 23 ZPU274KCE

40 ZP485KCE 24 ZPT274KCE

R-410A Copeland Scroll Digital™ modelsSingle Tandems

Capacity (HP)

ModelCapacity

(HP)Model

2.8 ZPD343.5 ZPD424.3 ZPD514.5 ZPD54

5 ZPD61 10 ZPDT12M6 ZPD72 12 ZPDT14M7 ZPD83 14 ZPDT16M9 ZPD103 18 ZPDT21M

10 ZPD120 20 ZPDT24M12 ZPD137 24 ZPDT27M13 ZPD154 26 ZPDT31M15 ZPD182 30 ZPDT36M

HCFC phaseout timeline

Features Advantages Benefits

Improved heat transfer characteristics of R-410A System compactness Cost-effective design

Higher energy efficiency ratio 2% - 5% higher energy savings Lower energy bills

Largest aftermarket network Close proximity for service needs Excellent product availability for contractors