Copeland Narrow Copevap
Transcript of Copeland Narrow Copevap
Copeland™ Narrow Copevap™
Condensing Units
Designed to Fit
2008ECT-11 R4.indd 12008ECT-11 R4.indd 1 7/30/2013 8:49:04 AM7/30/2013 8:49:04 AM
Configuration
ModelVoltages Available BOM
Codes115-1 phase 208/230-1 phase
M2TH-H020
IAA
---
108,118
M2TH-0024M2TH-0026M2TH-H033M2TH-0034M4TM-H020M4TM-H025M4TM-0033 IAVM4TL-H025
---M4TL-H033M4TL-H034
Control
Horse Power
BOMCrankcase
Heater
Low Pressure Control
High/Low Pressure Control
Contactor115 Volt Control Circuit
ALL ALL NO NO NO NO NO
* Data applies to units listed in this catalog only.
Copeland™ Narrow Copevap™ condensing units
The innovators who brought you the original Copeland
Copevap condensing unit are introducing a new platform to
the product offering – the narrow base. This narrow width unit
delivers reliability in a compact design that is ideally suited for
space limited refrigeration applications.
The narrow base unit features a compact condenser coil and
molded shroud that optimizes airflow across the entire coil
face. Its narrow 8.25” width fits nicely into a variety of space
limited applications. The condensate holding base and
discharge line design provide ample holding volume and a
quick evaporation rate for condensate removal. Many of the
most popular models feature high efficiency compressors and
all models have UL recognized agency approval. All standard
models feature a fan guard and a power cord designed for use
in 115 and 208/230 Volt, single-phase applications, with the
option to add a receiver tank. Engineered to provide reliable
performance in operating conditions up to 110°F, the Copeland
Narrow Copevap condensing unit is designed to fit and perform
to your demanding needs.
Bill of Material (BOM) codes
BOM Power Cord End Covers Receiver Fan Guard Agency Mark
108 YES YES NO YES ULR
118 YES YES YES YES ULR
Above BOM (Bill of Material) apply to the models listed in this catalog only.ULR is a registered trademark of Underwriters Laboratories, Inc.
Electrical Nomenclature
IAA / IAV Induction Run - Capacitor Start (High Starting Torque)
How to order1. Select base model number2. Select voltage3. Select BOM (options)
Complete model number to order
M2TH-H033 IAA 118
M2TH-H033-IAA-118
Molded Fan Shroud
Unit Bearing Fan Motors
Power Cord Standard
30% Larger Holding Volume
Narrow Base- 8.25” Width
High Effi ciency Compressors
Optional Receiver
Fan Guard Standard
Features Advantages Benefi ts
Narrow widthFits into confined spaces Versatile usage in space limited applications
Replaces other narrow applications Faster field service replacement
Molded plastic shroudImproved airflow across condenser coil Greater reliability in a small package
Material does not degrade when exposed to water Maintains airflow during life of product
Copeland™reliability Rated for usage up to 100oF ambient conditions Keeps performing in demanding applications
30% larger condensate holding volume
Handles more condensate from defrost cycles Eliminates potential over spills in a retail setting
Popular sizes feature high efficiency compressors
Higher efficiency operation Lower utility expenses for end-users
2008ECT-11 R4.indd 22008ECT-11 R4.indd 2 7/30/2013 8:49:32 AM7/30/2013 8:49:32 AM
Capacity
Hig
h T
emp
R-13
4a
Model H.P. Compressor 0° 5° 10° 15° 20° 25° 30° 35° 40° 45°Capacity (Btu/hr) at 90°F Ambient - Evaporator Temperature
M2TH-H020 1/5 ARE17C4E 760 870 980 1110 1240 1390 1540 1710 1890 2070
M2TH-0024 1/4 ARE25C3E 830 1010 1190 1370 1560 1760 1960 2170 2380 2610M2TH-0026 1/4 ARE27C3E 870 1100 1320 1530 1750 1970 2200 2430 2660 2910M2TH-H033 1/3 ARE34C4E 1430 1580 1760 1970 2190 2430 2680 2940 3210 3490M2TH-0034 1/3 ARE37C3E 940 1270 1560 1820 2070 2310 2550 2790 --- ---
Capacity (Btu/hr) at 100°F Ambient - Evaporator Temperature
M2TH-H020 1/5 ARE17C4E 700 800 910 1030 1160 1290 1440 1600 1760 1940
M2TH-0024 1/4 ARE25C3E 770 930 1100 1270 1440 1620 1810 2000 2210 2410M2TH-0026 1/4 ARE27C3E 730 960 1190 1400 1620 1830 2050 2260 2480 2710M2TH-H033 1/3 ARE34C4E 1320 1470 1630 1820 2020 2240 2470 2710 2960 3210M2TH-0034 1/3 ARE37C3E 830 1140 1420 1670 1910 2140 --- --- --- ---
Capacity (Btu/hr) at 110°F Ambient - Evaporator Temperature
M2TH-H020 1/5 ARE17C4E --- 730 840 950 1070 1190 1330 1470 1630 1790M2TH-0024 1/4 ARE25C3E 700 850 1000 1160 1330 1490 1670 1850 2030
---M2TH-0026 1/4 ARE27C3E
---830 1060 1270 1480 1680 1880 2090
---M2TH-H033 1/3 ARE34C4E--- ---
1670 1860 2050 2260---
M2TH-0034 1/3 ARE37C3E --- --- --- ---
Med
ium
Tem
pR-
404A
Model H.P. Compressor -5° 0° 5° 10° 15° 20° 25°Capacity (Btu/hr) at 90°F Ambient - Evaporator Temperature
M4TM-H020 1/5 ASE12C4E 870 960 1080 1200 1320 1450 1580M4TM-H025 1/4 ASE20C4E
---1580 1750 1900 2050 2210 2370
M4TM-0033 1/3 ASE24C3E 1570 1760 1940 2130 2340 2570Capacity (Btu/hr) at 100°F Ambient - Evaporator Temperature
M4TM-H020 1/5 ASE12C4E---
850 960 1060 1170 1290 1400M4TM-H025 1/4 ASE20C4E 1490 1610 1730 1850 1970 2100M4TM-0033 1/3 ASE24C3E 1360 1540 1720 1910 2110 2350
Capacity (Btu/hr) at 110°F Ambient - Evaporator TemperatureM4TM-H020 1/5 ASE12C4E
--- ---840 930 1030 1120 1220
M4TM-H025 1/4 ASE20C4E 1490 1570 1650 1730 1820M4TM-0033 1/3 ASE24C3E 1370 1540 1740 1950 ---
Low
Tem
pR-
404A
Model H.P. Compressor -25° -20° -15° -10° -5° 0° 5° 10° 15°Capacity (Btu/hr) at 90°F Ambient - Evaporator Temperature
M4TL-H025 1/4 AFE08C4E 640 720 810 910 1010 1120 1230 1350 1470M4TL-H033 1/3 AFE11C4E 830 940 1060 1190 1330 1480 1640 1800 1960M4TL-H034 1/3 AFE13C4E 1100 1250 1400 1570 1750 1940 2140 2330 2540
Capacity (Btu/hr) at 100°F Ambient - Evaporator TemperatureM4TL-H025 1/4 AFE08C4E 570 650 730 820 920 1020 1120 1230 1330M4TL-H033 1/3 AFE11C4E 740 840 960 1080 1210 1340 1490 1630 1780M4TL-H034 1/3 AFE13C4E 990 1130 1280 1440 1600 1770 1950 2130 2310
Capacity (Btu/hr) at 110°F Ambient - Evaporator TemperatureM4TL-H025 1/4 AFE08C4E 480 560 640 730 820 910 1010 1110 1210M4TL-H033 1/3 AFE11C4E
---760 860 970 1090 1210 1340 1470 1600
M4TL-H034 1/3 AFE13C4E 960 1100 1240 1380 1520 1680 1830 1990Low and Medium Temperature units are rated at 40oF return gas; High Temperature units are rated at 65oF. Capacities are at 60 Hz with 5oF sub-cooling. Multiply by .83 for 50 Hz.
Physical/Electrical
ModelDimensions (in) Connecting Lines (in) MCA/Max Fuse Size Pump Down
Capacity (lbs)Ship Weight
(lbs)Unit Width (in)
-118 BOML W H Suction Liquid 115-1-60 208/230-1-60
M2TH-H020
19 8.25 10.55/16
Sweat1/4
Sweat
6.1 / 15
---2.2
36
9.35
M2TH-0024 6.76 / 15 34
M2TH-0026 7.1 / 15 35M2TH-H033 6.63 / 15 35M2TH-0034 9.9 / 15 35M4TM-H025 7.38 / 15
1.9
34M4TM-0033 8.38 / 15 6.13 / 15 35M4TM-H020 5.6 / 15
---
35M4TL-H025 5.76 / 15 34M4TL-H033 6.13 / 15 35
M4TL-H034 7.90 / 15 36
The holding volume of the Copeland Narrow Copevap is 49 oz. It evaporates at a rate of 6.8 oz. when half full and 12.5 oz. when full.The evaporation rate is based on the following assumptions: measured over a 3 hour period, 80oF ambient, 50% humidity and 33oF incoming water.
Height
LengthWidth
2008ECT-11 R4.indd 32008ECT-11 R4.indd 3 7/30/2013 8:49:33 AM7/30/2013 8:49:33 AM
2008ECT-11 R4 (7/13) Emerson, Copeland and Copevap are trademarks of Emerson Electric Co. or one of its affiliated companies. ©2013 Emerson Climate Technologies, Inc. All rights reserved.
Application Engineering Bulletins
4-125 HFC-134A Refrigerant Guidelines4-1298 Extended Medium Temperature R-404A/507 Hermetic Compressors and Condensing Units4-1305 System Pro AF, R, AS Refrigeration Hermetic 1/8-1 Horsepower Compressors5-1340 Care And Cleaning Of Air-Cooled Condensing Units17-1260 Compressor Overheating17-1268 Compresor Ratio as it Affects Compressor Reliability22-1182 Liquid Refrigerant Control in Refrigeration and Air Conditioning Systems
For more information on Copeland condensing units visit EmersonClimate.com/IntegratedProducts
2008ECT-11 R4.indd 42008ECT-11 R4.indd 4 7/30/2013 8:49:34 AM7/30/2013 8:49:34 AM