Cool barrier interior relux ppt Watergy

20
S m a r t F u n c t i o n a l P a i n t s Energy Savings: Interior Wall Paint Cool Barrier Relux More Lighting Power to your Buildings!

Transcript of Cool barrier interior relux ppt Watergy

Page 1: Cool barrier interior relux ppt Watergy

S m a r t Fu n c t i o n a l P a i n t s Energy Savings: Interior Wall Paint

Cool Barrier Relux

More Lighting Power

to your Buildings!

Page 2: Cool barrier interior relux ppt Watergy

S m a r t Fu n c t i o n a l P a i n t s Energy Savings: Interior Wall Paint

Buildings: Luminous Interior Wall Paint (Cool Barrier Relux)

Exceptional Visible and Usable Light Reflectance

Excellent Stain Removal

Excellent Grease Resistance

Excellent Adhesion over old oil based paints

Very Good Block Resistance

Almost Zero VOC Content Formulation

Very good wet scrub performance (Easy Clean)

Luminance: Quantifies the

brightness of a light source or of an illuminated surface that reflects light. Luminance indicates

how much luminous power will be

detected by an eye looking at the

surface from a particular angle of view, thus being an indicator of how bright the surface will appear

Page 3: Cool barrier interior relux ppt Watergy

S m a r t Fu n c t i o n a l P a i n t s Energy Savings: Interior Wall Paint

What is Light ?

Light is that part of the electromagnetic spectrum that is perceived by our eyes. The wavelength range is between 380 and780 nm.

Optimum energy efficiency Large buildings provide huge potential for optimisation of energy consumption.

Source: Zumtobel Lighting GmbH

Page 4: Cool barrier interior relux ppt Watergy

S m a r t Fu n c t i o n a l P a i n t s Energy Savings: Interior Wall Paint

The Triple Effect

• Light for visual functions Illumination of task area in conformity with relevant standards

Glare‐free and convenient

• Light for emotional perception Lighting enhancing architecture

Creating scenes and effects

• Light creating biological effects Supporting people’s circadian rhythm

Stimulating or relaxing

Source: Zumtobel Lighting GmbH

Page 5: Cool barrier interior relux ppt Watergy

S m a r t Fu n c t i o n a l P a i n t s Energy Savings: Interior Wall Paint

Basic Parameters Used in Lighting

Luminous flux – Luminous intensity

Luminous flux

The luminous flux describes the quantity

of light emitted by a light source. The luminous efficiency is the ratio of the luminous flux to the electrical power consumed (lm/W). It is a measure of a light source’s economic efficiency. Unit: lm Lumen

Luminous intensity

The luminous intensity describes the

quantity of light that is radiated in a

particular direction. This is a useful measurement for directive

lighting elements such as reflectors. It is

represented by the luminous intensity

Distribution curve (LDC). Unit: cd Candela

Source: Zumtobel Lighting GmbH

Page 6: Cool barrier interior relux ppt Watergy

S m a r t Fu n c t i o n a l P a i n t s Energy Savings: Interior Wall Paint

Basic Parameters Used in Lighting

Illuminance – Luminance

Illuminance

Illuminance describes the quantity of luminous flux falling on a surface. It decreases by the square of the distance

(inverse square law). Relevant standards specify

the required illuminance (e.g. EN 12464

“Lighting of indoor workplaces”).

Luminance

Luminance is the only basic lighting

parameter that is perceived by the eye. It specifies the brightness of a surface and is

essentially dependent on its reflectance

(finish and colour). Unit: cd/m2

Page 7: Cool barrier interior relux ppt Watergy

LIGHT BLUE

CB 013

Matt finish

LIGHT RED

CB 015

Matt finish

LIGHT GREEN

CB 016

Matt finish

LIGHT GREY

CB 022

Matt finish

LIGHT OCHRE

CB 019

Matt finish

How RELUX works 1

The enabled technology allows an excellent reflection in the visible spectrum of the lighti n a

much higher level in comparison to standard

available colour range options.

The appearance of the treated areas is improved, the ambience and the luminance of the room is more bright whilst using up to 20% less light energy.

The Luxlite colour range is available in a selection of colours with cleaner tinting – all of which are up to

twice as reflective as normal paint so that light is

distributed around a space more effectively.

LUXLITE

WHITE Matt finish

S m a r t Fu n c t i o n a l P a i n t s Energy Savings: Interior Wall Paint

Page 8: Cool barrier interior relux ppt Watergy

How RELUX works 2

Natural Light By using Relux instead of a standard paint with a similar hue and chroma, it’s possible to have up to 20% less natural light entries, yet still achieve the same levels of light within the room.

Artificial Light By distributing light more efficiently, Light & Space paint also saves energy by reducing artificial lighting. A room can benefit from the same average level of illumination whilst using up to 20% less lighting energy.

A simple way to make rooms become lighter and brighter !

S m a r t Fu n c t i o n a l P a i n t s Energy Savings: Interior Wall Paint

Page 9: Cool barrier interior relux ppt Watergy

RELUX Extra Benefits

Allowing High Light Reflective wall colours whilst still meeting visual contrast for the visual Impaired people

More Info about Luminance Contrast Testing here: http://www.disabilityaccessconsultants.com.au/luminance‐testing/

S m a r t Fu n c t i o n a l P a i n t s Energy Savings: Interior Wall Paint

Page 10: Cool barrier interior relux ppt Watergy

S m a r t Fu n c t i o n a l P a i n t s Energy Savings: Interior Wall Paint

Luminous Interior Wall Paint Simulation Case Study 1* (Energy efficient lighting)

Reference (office)

• Regular array of suspended T8 fluorescent luminaires. • Luminaire efficiency (light output ratio) of 60%. • 30 % of the energy used for indirect lighting. • Magnetic ballasts. • Near uniform horizontal work plane luminance of 500 lux. • Little use of individual task lighting. • Manual control of lighting ‐ no daylight or occupancy sensors, and no timer. • Little flexibility – few possibility for individual lighting adjustments. Surface reflectance values for floor, walls and ceiling of 20%, 50% and 70%

respectively.

*SOURCE: Energy efficient lighting Technologies and solutions for significant energy savings compared to

current practice Tore Kolås, November 2011 Sintef

Page 11: Cool barrier interior relux ppt Watergy

S m a r t Fu n c t i o n a l P a i n t s Energy Savings: Interior Wall Paint

Luminous Interior Wall Paint Simulation Case Study 2

Factors influencing lighting energy use

• Lighting equipment luminous efficacy of light source luminaire efficiency ballast type maintenance factor

• Lighting installation design electric lighting distribution (uniformity) reflectance of interior surfaces

• Occupancy scheduling occupant behavior type of control system

• Daylight harvesting occupant behavior control system for lighting and shading type of daylighting or shading system building‐related factors

Energy efficient lighting Technologies and solutions for significant energy savings compared to current practice Tore Kolås, November 2011 Sintef

Page 12: Cool barrier interior relux ppt Watergy

S m a r t Fu n c t i o n a l P a i n t s Energy Savings: Interior Wall Paint

Luminous Interior Wall Paint Simulation Case Study 3

Luminous efficacy of light source

• Future developments in solid state lighting

(LED) is likely to improve luminous efficacy

of electric light sources significantly. • This could have a strong and direct impact

on lighting energy loads! • Estimated future saving potential is about

50 % compared to T5 fluorescent. • Switch from the T8 fluorescent source

(reference office) to the T5 source can save 15% energy.

Energy efficient lighting Technologies and solutions for significant energy

savings compared to current practice Tore Kolås, November 2011 Sintef

Page 13: Cool barrier interior relux ppt Watergy

S m a r t Fu n c t i o n a l P a i n t s Energy Savings: Interior Wall Paint

Luminous Interior Wall Paint Simulation Case Study 4

Luminaire efficiency

• Light output ratio (LOR) depends on luminaire design, including the optical properties of the reflector materials.

• Advances in reflector material optical properties have increased the light output ratio of luminaries considerably over the last two decades.

• Today, high performance fluorescent luminaires provide light output ratios of more than 0.9.

• Energy savings relative to the reference situation (LOR=0.6) is about 33%.

Energy efficient lighting Technologies and solutions for significant energy

savings compared to current practice Tore Kolås, November 2011 Sintef

Page 14: Cool barrier interior relux ppt Watergy

S m a r t Fu n c t i o n a l P a i n t s Energy Savings: Interior Wall Paint

Luminous Interior Wall Paint Simulation Case Study 5

Ballast type

• Magnetic ballasts used to be the standard for fluorescent lighting.

• Today, electronic ballasts have replaced the old standard.

• Electronic ballasts typically use 25% less energy.

• Energy savings relative to the reference situation is about 25%.

Energy efficient lighting Technologies and solutions for significant energy

savings compared to current practice Tore Kolås, November 2011 Sintef

Page 15: Cool barrier interior relux ppt Watergy

S m a r t Fu n c t i o n a l P a i n t s Energy Savings: Interior Wall Paint

Luminous Interior Wall Paint Simulation Case Study 6

Maintenance factor

• Lamp data The ratio between the maintained and the initial illuminance

value is the maintenance factor (MF). MF depends on:

• Lumen maintenance curve • Lamp survival curve • Dirt aspects • Luminaire • Room • Surroundings • Maintenance procedure • Spot replacement or group replacement • time between group replacements

The energy saving potential according to Jacobsen (1997) can

be as high as 15‐20 % for fluorescent lighting installations.

In the LECO report on energy

efficient lighting a more

conservative estimate of 10%

energy savings from improved

maintenance is used.

Energy efficient lighting Technologies and solutions for significant energy

savings compared to current practice Tore Kolås, November 2011 Sintef

Page 16: Cool barrier interior relux ppt Watergy

S m a r t Fu n c t i o n a l P a i n t s Energy Savings: Interior Wall Paint

Luminous Interior Wall Paint Simulation Case Study 7

Electric lighting distribution

• Separate individual task lighting and general building lighting as discussed by Loe

(2003). This can produce a non‐uniform lighting distribution with lower levels in

areas where less light is needed.

• Care should be taken not to negatively influence the lighting comfort!

• Veitch et al. (1998) estimates around 50% energy saving potential.

• Loe (2003) provides a more conservative estimate of 25%.

• There has been little research in this field and the estimates given above are not well documented.

Energy efficient lighting Technologies and solutions for significant energy

savings compared to current practice Tore Kolås, November 2011 Sintef

Page 17: Cool barrier interior relux ppt Watergy

S m a r t Fu n c t i o n a l P a i n t s Energy Savings: Interior Wall Paint

Luminous Interior Wall Paint Simulation Case Study 8

Interior surface reflectance

The reflectance values of the interior are of great importance for the lighting

comfort.

Standard values used in calculations are 0.70 for ceiling, 0.50 for walls and 0.20

for the floor cavity.

For typical interiors, significant savings can easily be obtained by increasing the

interior reflectance values.

When both direct and indirect lighting (30%) is used, estimated savings are

about 25% when the interior surfaces of ceiling, walls and floor are set to 0.9, 0,7 and 0.5 respectively .

Energy efficient lighting Technologies and solutions for significant energy

savings compared to current practice Tore Kolås, November 2011 Sintef

Page 18: Cool barrier interior relux ppt Watergy

S m a r t Fu n c t i o n a l P a i n t s Energy Savings: Interior Wall Paint

Luminous Interior Wall Paint Simulation Case Study 9

Occupancy scheduling ‐ conclusions

• The literature findings indicate typical occupancy rates of about 30‐50 % during

office hours. • This gives a savings potential of about 50‐70 % compared to an “always on during

office hours” lighting regime. • The saving potential compared to a manual switching regime is 54‐67 %. • More field studies are needed to verify the saving potential in Norway. • However, it seems clear that the saving potential is greater than the 20% indicated by

NS3031 (2007). • In the LECO report a saving potential of 40% compared to manual switching is used.

Energy efficient lighting Technologies and solutions for significant energy savings compared to current practice Tore Kolås, November 2011 Sintef

Page 19: Cool barrier interior relux ppt Watergy

Luminous Interior Wall Paint Simulation Case Study 10

Daylight harvesting ‐ conclusions

• Several studies indicate large saving potential (30% to 70%) in the daylit area, even without the use of any special daylighting components.

• Window area and transmittance are important, and savings are reported to

increase linearly for typical values of the “daylight aperture” (TwAw/Ap). • Savings increase significantly with automatic control systems for electric lighting

and for shading.

Energy efficient lighting Technologies and solutions for significant energy

savings compared to current practice Tore Kolås, November 2011 Sintef

S m a r t Fu n c t i o n a l P a i n t s Energy Savings: Interior Wall Paint

Page 20: Cool barrier interior relux ppt Watergy

Measure Saving

potential [%]

Energy

consumption

[kWh/m2]

Reference conditions (no measure) ‐ 47

BeƩer light source (T8→T5) 15 40

Switch from electromagnetic to electronic ballasts 25 30

Better luminaires (LOR 0.6→0.9) 33 20

Presence detectors (real occupancy control strategy) 40 12

Daylight dimming 15* 10

Automatic shading (+ daylight dimming) 15* 8,7

Daylight redirection systems (+ daylight dimming) 20* 7

Improved maintenance procedures 10 6.3

Non‐uniform spatial distribution of electric lighting 25 4.7

Brighter interior surfaces** 25 3.5

Luminous Interior Wall Paint Simulation Case Study 11

Total energy saving

for lighting

Brighter interior surfaces 25% Energy

Savings

** ceiling, walls and floor are set to 0.9, 0,7 and 0.5 respectively .

Miljøbygget Prof. Brochs gt 2

* Numbers refer to average savings for the whole building. Higher savings can be obtained in the daylit areas.

www.abolinco.com

S m a r t Fu n c t i o n a l P a i n t s Energy Savings: Interior Wall Paint