Conveyor Technology
-
Upload
shamim-ahsan-parvez -
Category
Documents
-
view
43 -
download
6
Transcript of Conveyor Technology
Siemens – Product overview for drive and automation solutions in conveyor technologyGeared motors
Catalog
Output torque/motor power
Output speed/ratio
Type of enclosure
Shaft design
Voltage/frequency
Encoder
Helical geared motors
D 87.1
4 … 20000 Nm0.09 … 200 kW
0.05 … 2100 rpm1.36 … 24996
Foot-/flange-mounted design
Solid shaft with feather key,shafts with metric and inch dimensions
Parallel shaft geared motors Bevel helical geared motors
D 87.1 D 87.1
7 … 34000 Nm0.09 … 200 kW
6 … 20000 Nm0.09 … 200 kW
0.05 … 773 rpm3.8 … 29000
0.05 … 790 rpm3.57 … 27817
Solid shaft with feather key, hollow shaft with feather key,hollow shaft with shrink disk, shafts with metric and inch dimensions
All generally used voltages and frequencies,special motor windings on request
Resolvers, incremental encoders, absolute encoders
Helical worm geared motors Worm geared motors Servo helical geared motors Servo offset-shaft geared motors Servo bevel helical geared motors
D 87.1 D 87.1 PM 21 PM 21 PM 21
19 … 1590 Nm0.09 … 9.2 kW
10 … 80 Nm0.12 … 1.1 kW
3.63 … 1737 Nm0.3 … 8 kW
4.07 … 587 Nm0.3 … 7.93 kW
3.78 … 1626 Nm0.3 … 7.83 kW
0.05 … 299 rpm9.67 … 6722
9.0 … 560 rpm15 … 100
43 … 782 rpm3.8 … 70
85 … 696 rpm4.3 … 35
39 … 750 rpm4 … 70
Flange-, foot-mounted design, circle of threaded holes,foot & flange, foot & circle of threaded holes, torque arm
Solid shaft with feather key Solid shaft with feather key, hollow shaft with keywayor with clamping element/shrink disk
Servo worm geared motors
PM 21
8.5 … 399 Nm0.28 … 4.45 kW
40 … 326 rpm9.2 … 70
Foot-, flange-mounted design,torque arm, circle of threaded holes
Planetary geared motors
PM 21
2 … 3400 Nm0.3 ... 57 kW
120 … 1500 rpm5, 10
Inverter operation with SINAMICS S120
Motor-integrated encoder systems:Resolvers, incremental encoders (1 Vpp sin/cos), absolute encoders (EnDat)
Flange, circle of threaded holes
Solid shaft with/without feather key
Additional geared motors, see www.siemens.com/gearedmotors Power distribution
Rated peak withstand current Ipk up to
Degree of protection
Rated currents up to
Catalog
Rated operational voltage up to
No. of poles
Rated ultimate short-circuitbreaking capacity (Icu)
Brief description
Special features
Switchboards SIVACON Circuit breaker/switch disconnector SENTRON Power Monitoring devices SENTRON PAC
–
–
–
LV 1; LV 50 LV 1; LV 1 T
Power transmission between transformer and switchboard / power distribution betweentransformer and downstream switchboards or switchboard and loads
Air circuit breakers andmolded case circuit breakers
Precise detection/display of power values ofelectrical feeders or individual loads and of measured
values for assessing system state / power quality
7000 A
690 V
16 … 6300 A
1000 V
Up to IP54
330 kA
3-4 poles
150 kA
Integrated in the switchboard
Flexibility – modular designPlant-wide transparency – communication-capable
High degree of safety – with type-tested systems and busbar connections;Plant-wide transparency – using communication-capable modules
Remote service/remote access – Possible Possible Possible
Interfaces RS 485PROFIBUS DP, MPI
PPI/MPI/USB/PROFIBUS/PROFINET
PPI/MPI/USB/PROFIBUS/PROFINET
PPI/MPI/USB/PROFIBUS/PROFINET
Display size No display 3 … 12 inches 6 … 19 inches 6 ... 8 inches
Input types Short stroke keys Keys Touch Touch and keycombined
Color / b/w Multi-color flat LEDs Pixel graphics b/wup to full graphics, color
Color Color
Applications
Communication
Catalog
Interfaces
Operator control and monitoring Sensors Communication
SIMATICPush Button Panel
SIMATICOperator Panel
SIMATICTouch Panel
Applications
Communication
Physical principle
Configuration software;integrated evaluation units,components of the modular
Safety Integrated system
Completely integrated into SIMATIC;extremely high clock-pulse rates are possible
0 … 70 m –
Optical Optical
FS 10 ID 10
Fail-safepresence detection
Identification, reading 1D/2D codes
SIMATIC FSFail-safe sensors
Code reading systemsSIMODRIVE Sensormeasuring system
AS-Interface, PROFIBUS Industrial Ethernet/PROFINET, PROFIBUS,serial interface
Engineering tool Directly at the device WinCC flexible WinCC flexible WinCC flexible
SIRIUS Commandingand signaling devices
AS-Interface I/O modules
SIRIUS Hinge switches,short-stroke switches,
magnetically-operated switches
SIRIUS Position switches
–
AS-Interface
–
Mechanical(push, pull, knob, latching)
Various; lit(incandescent lamp/LED)
Online Configurator (Industry Mall)Offline Configurator on DVD (CA01)
Brief description
Catalog LV 1 ST 80 ST 80 ST 80 ST 80
EMERGENCY STOP pushbuttons andpushbuttons (in encapsulated/
non-encapsulated versions), indicatorlights, signaling columns, integrated signal
lamps, two-hand operation console,foot switch, cable-operated switches
Bus-capable alternativeto conventional operator
panels with keys
With membrane keyboard Withtouch-sensitive
display
Mobile operator devicefor local operator
control and monitoring/with cable or wireless
via IWLAN
Special functions
Range/measuring range
Physical principle
Catalog
Applications
Communication
Brief description
Catalog
To mechanically sense motionsequences. To mechanicallymonitor protective devices.
AS-Interface
Mechanical
Mechanical sensors – standard andwith separate actuator with/without
solenoid interlocking mechanism;enclosure versions for all environmental
conditions (IP20/66/67 in mouldedplastic or metal); contacts for variouscontrol tasks (fast action/slow action
contacts): standard position switches:Various actuators for approach and
actuation situations; separate actuator;Coded actuators offer a higher degree of
protection against manipulation
LV 1; LV 1 T
To mechanically monitor protectivedevices, protective doors or
protective flaps. For preciselydetermining the position.
AS-Interface
Mechanical/magnetic
Mechanical and magnetic sensors;Magnetically-operated switches:coded switching magnets offersecurity against manipulation;
Short-stroke switches:double fast switching with respect
to standard switches;Hinge switches:
for small switching angles
LV 1; LV 1 T
Input/output module tointegrate sensors and
actuators into AS-Interface.
AS-Interface
Digital/analog
– Modules in degree of protectionIP20/67/68/69K
– Up to 62 modules or 496 inputs/496 outputs (Spec. 3.0)
connected to an AS-I network– Safety inputs
– Compact module K20 with a especiallylow-profile design (20 mm) available– Module with 4 inputs/4 outputs for
extended adress mode (Spec 3.0)– Fast analog modules for data transfer
times twice as fast (Spec. 3.0)
LV 1; LV 1 T; IK PI
Variable (incremental/absolute)
Optical
PM 21
Position, angle,velocity measurement
Digital, RS 422, SSI,PROFIBUS DP; analog 1 Vpp
Optical
FS 10
Presence/absence counting,position measuring, position detection,
pattern/shape comparison,color evaluation
Vision Sensors
Industrial Ethernet/PROFINET,PROFIBUS
Vision SensorsLight curtains, grids,laser scanners, light barriers,
switching strips
Code reading systems MV420/MV440/VS130-2Brief description
www.siemens.com/conveyor-technology
SIPLUS CMSCondition
Monitoring System
Sensor: 0 … 300 m / ±5 g
Vibration acceleration
LV 1
Long-term monitoring of motors, gears and fans
Bearing guard for constant and variablerotation speed, recognition of unbalance
Local configuration and LC display
Safety Integrated PP17-I PROFIsafe – – STOP (Cat. 3, EN 954-1)/Wireless:EMERGENCY STOP (Cat. 4 SIL3)
Standard wired/ASIsafe
© Siemens AG 2010 | Order No. 6ZB5711-0AG02-0AA4
Safety Integrated Standard wired/ASIsafe ASIsafe Yes
Read/write units with IQ-Sense; completelyintegrated into SIMATIC; heat resistant;
file handling; memory capacity up to 64 KB;frequencies: 1.81 MHz, 13.56 MHz, 2.54 GHz,865 … 868 MHz (Europe), 902 … 928 MHz (USA)
0 … 300 m
Radio frequency
ID 10
Presence detection,identification,
reading/writing data
SIMATIC RFRFID systems
Industrial Ethernet/PROFINET, PROFIBUS,serial interface
MOBY D/SIMATIC RF600;MOBY E/U, RF300;
MOBY R
– –Safety Integrated – –
Mounted encoder to senseposition, angle and speed
Absolute encoderwith PROFIBUS
can be parameterized
2 isolated signalling contacts
Brief description
SIMATICMobile Panel/
Mobile Panel IWLAN
Catalog
Type of construction
Design
Connection systemfor sensors/actuators
Technological functions
Isochronous mode
Safety Integrated / high availability
Digital channels/analog channels
Communication
Degree of protection
Controllers
ST 70
Modular logic modules for control tasksin the lowest performance range
New: Text display set down
< 0.1 ms/function block
200 function blocks
Memory card,200 function blocks
Max: 24/16 digital,8/2 analog
Brief description
I/O address area, max.
Execution time for bit operation, min.
Main memory, max.
Load memory/mass storage, max.
Catalog
I/O devices
Diagnostics
Permanent wiring
Temperature rangeIntegration of PC standard HW/SW –
ST 70
Modular, compact controllers fordiscrete and stand-alone automation
solutions
SIMATIC S7-1200Modulare Controller
0.1 µs
50 Kbytes (CPU 1214C)
2 MB (CPU 1214C)
1024/1024 bytes
–
ST 70
SIMATIC S7-300Modulare Controller/
Distributed I/O system ET 200 with CPU
SIMATIC S7-300: For the lower up to the mediumperformance range; CPU ET 200S and ET 200pro:
Distributed I/O system with local intelligence
S7-300: 0.004 µs;IM 151-7 / IM 151-8 / 154-8 CPU: 0.1 µs
S7-300: 2.5 MB; IM 151-7 CPU: 96 Kbytes;IM 151-8 CPU: 128 Kbytes;IM 154-8 CPU: 256 Kbytes
S7-300: 8192/8192 bytes; IM 151-7 CPU:244/244 bytes; IM 151-8 CPU: 2048/2048 bytes;
IM 154-8 CPU: 2048/2048 bytes
Micro Memory Card 8 MB
– Yes
ST 70; ST PC
S7-mECModulare Embedded Controller
Embedded controller in modular S7-300 design(no fan, no disk), optionally pre-installed
with Windows XP embedded, WinAC RTX (F)or WinCC flexible
0.01 µs,Pentium M 1.4 GHz
16384/16384 bytes
2 GB Compact Flash-Card
1 GB RAM
Yes
ST 70; ST PC
SIMATICHMI IPC477C Bundle
Embedded Panel PC (no fan, no disk),pre-installed with Windows XP embedded,
WinAC RTX (F) and either with WinCC flexible RTor WinCC (single user or client)
0.01 µs, with high-performance processors:Celeron M 1.2 GHz; Core2Solo 1.2 GHz
Core2Duo 1.2 GHz
16384/16384 bytes
Up to 8 GB Compact Flash-Cardresp. 32 GB Solid-State-Disk
1 GB RAM, 2 GB RAM, 4 GB RAM
Yes
ST 70; ST PC
SIMATIC WinAC RTX (F)
Software controller – open,flexible, for standard and industrial PCs
0.004 µs(PC-dependent)
Dependent on the PC mass storage
Available PC working memory
16384/16384 bytes
Yes
ST 70
SIMATIC S7-400Modulare Controller
Modulare power controllers for themedium up to the higher
performance range
16384/16384 bytes
Memory Card 64 MB
–
0.018 µs
30 MB
ST 70; ST PC
SIMATIC IPC427C Bundle
Embedded, turnkey DIN rail PC, pre-installedwith Windows XP embedded, WinAC RTX (F)
and optionally WinCC flexible RT
16384/16384 bytes
Up to 8 GB Compact Flash-Cardresp. 32 GB Solid-State-Disk
1 GB RAM, 2 GB RAM, 4 GB RAM
SIMATIC ET 200S
IK PI
IP20
Finely modular, expandable block
Mounting rail
Counting/measuring,positioning, weighing
Yes
Yes/–
Yes/Yes
Multi-conductor terminals,spring-loaded/screw terminals,
Fast Connect
PROFIBUS, PROFIBUS with PROFIsafe,PROFINET, PROFINET with PROFIsafe
Channel-specific
Yes
0 … +60 °C
SIMATIC ET 200M
IK PI
IP20
Modular
Profile rail
Counting/measuring, positioning,cam control, closed-loop control, weighing
Yes
Yes/switched, redundant
Yes/Yes
Single-conductor terminals,spring-loaded-/screw-terminals,
Top Connect, Fast Connect
PROFIBUS, PROFIBUS with PROFIsafe,PROFINET
Channel-specific
Yes
0 … +60 °C
SIMATIC ET 200pro
IK PI
IP65/66/67
Modular
Profile rail
–
Yes/–
Yes/Yes
M12
PROFIBUS, PROFIBUS with PROFIsafe,PROFINET, PROFINET with PROFIsafe
–
Channel-specific
Yes
0 … +55 °C (partially down to –25 °C)
SIMATIC ET 200eco / eco PN
IK PI
IP65/67
Block
Direct mounting
–
Yes/–
Yes/–
M12
PROFIBUS,PROFIBUS with
PROFIsafe
–
Module-specific
–
0 … +55 °C
LOGO! SIMOTION P
PM 21
PC-basedmotion control system
• open platform
Load memory: 16 MBMass storage: Hard disk
14 MB
Logical: 4 Kbytes;Physical: 1 Kbyte per DP line,
4 Kbytes for PROFINET
–
0.01 µs
SIMOTION D
PM 21
Drive-basedmotion control system
• compact platform
Load memory: 11/23 MBMass storage: 128 MB
Compact Flash: 128 MB
15 MB (D425/D435),30 MB (D445)
Logical: 16 Kbytes;Physical: 1 Kbyte per DP line,
4 Kbytes for PROFINET
–
0.01 µs
–
–/–
SIMOTION C
PM 21
Controller-basedmotion control system
• modular platform
Load memory: 11 MBMass storage:
Micro Memory Card 32 MB
15 MB
Logical: 2 KbytesPhysical: 1 Kbyte per DP line
MOTION CONTROL via PLCopen as well as via highly flexible, high performance system functions for servo, vector,stepping and hydraulic drives, pressure and temperature control
PROFINET/PROFIBUS
One engineering system SCOUT for all tasks:Project management, motion control, PLC, technology, HMI, commissioning, testing and diagnostics etc.
–
0.05 µs
CPU-integrated
–/–
LOGO! Soft Comfort V6.0
AS-Interface, KNX Instabus EIB
Technological functions
Safety Integrated / high availability
Engineering
Communication
Interfacing of C/C++ –
CPU-integrated
STEP 7 Basic V10.5
PROFINET (for programming,HMI interfacing and
CPU-to-CPU communication)
–
–/–
Loadable function blocks, CPU-integrated,function, application modules, T-CPU
F-CPU
STEP 7/STEP 7 Professional
AS-Interface (via DP/AS-i LINK Advancedor IE/AS-i LINK PN IO),
PROFIBUS (T-CPU: PROFIdrive, F-CPU: PROFIsafe),PROFINET (F-CPU: PROFIsafe)
–
ST 70; ST PC
SIMATIC WinAC MP
Software PLC on a multi-functionalplatform (no fan, no hard disk)
with Windows CE
16384/16384 bytes
1 MB integrated
0.2 µs
5 MB flash1 MB work memory
Loadable function blocks
–/–
PROFIBUS
Yes
Loadable function blocks
Yes/–
PROFIBUS, PROFINET
Yes
Loadable function blocks
Yes/–
PROFIBUS, PROFINET
Yes
Loadable function blocks
Yes/–
PROFIBUS/PROFINET
Yes
Loadable function blocks, function,application modules (isochronous)
F-CPU/FH-CPU/H-CPU
AS-Interface (via DP/AS-i LINK Advancedor IE/AS-i LINK PN IO),
PROFIBUS (F-CPU: PROFIsafe),PROFINET (F-CPU: PROFIsafe)
–
Loadable function blocks
Yes/–
PROFIBUS, PROFINET
–
–/–
–
–/–
Motor starters and inverters
Safe disconnection via PROFIsafe or local, STO1)
Catalog
Line supply voltage
Power rating
Output voltage
Motors suitable for connection
Communication
Safety Integrated
Switching/control principle
Output frequency
1) STO: Safe Torque Off; SS1: Safe Stop 1; SS2: Safe Stop 2; SSM: Safe Speed Monitor; SLS: Safely Limited Speed; SOS: Safe Operating Stop; SBC: Safe Brake Control; SBR: Safe Brake Ramp 2) SS1 and SLS, sensorless operation 3) Max. 40 °C ambient temperature
LV 1; IK PI
Up to 690 V 3 AC (circuit-breakers,load feeders, compact starters, soft starters)
100 A/45 kW circuit-breakers; 500 A/250 kW contactors;41 A/22 kW pre-wired load feeders;
32 A/15 kW compact starters; 1214 A/710 kW soft starters
–
Induction motors
I/O-Link, AS-Interface, PROFIBUS DP
Direct, reversing starters,star-delta, soft starters
50/60 Hz
Safety-relevant design possible
SIRIUS Modular system(Switching, Protecting, Starting, Monitoring)
Degree of protection
SIMATIC ET 200SMotor starters
LV 1; IK PI
Up to 500 V 3 AC
0.06 … 7.5 kW
VLINE
Induction motors
PROFIBUS, PROFIBUS with PROFIsafe,PROFINET, PROFINET with PROFIsafe
Direct, reversing, soft starters
50/60 Hz
IP20
SINAMICS G110Inverter
D 11.1
200 … 240 V 1 AC
0.12 … 3 kW
0 ... VLINE
Induction motors
USS (RS 485)
–
V/f control
0 ... 650 Hz
IP20
SIRIUS MCUMotor starters
LV 1; IK PI
Up to 690 V 3 AC
0.12 … 5.5 kW
VLINE
Induction motors
I/O-controlled, AS-Interface
Direct, reversing starters
50/60 Hz
IP54
SINAMICS G120Inverter
D 11.1
380 … 480 V 3 AC,660 … 690 V 3 AC
0.37 … 132 kW
0 ... VLINE
Induction motors
PROFIBUS, PROFIBUS with PROFIsafe3),PROFINET, PROFINET with PROFIsafe, USS (RS 232/485)
STO, SS1, SLS, SBC1) 2); via PROFIsafe and F-DI
V/f control,vector control with/without encoder
0 ... 650 Hz (V/f control)
IP20
SINAMICS S120AC-Drive
PM 21
200 … 240 V 1 AC,380 … 480 V 3 AC
0.12 … 0.75 kW (200 … 240 V 1 AC),0.37 … 90 kW (380 … 480 V 3 AC)
0 ... VLINE
Induction motors, synchronous motors, torque motors, linear motors
PROFIBUS, PROFIBUS with PROFIsafe,PROFINET, PROFINET with PROFIsafe
STO, SS1, SS2, SOS, SLS, SSM, SBC; via PROFIsafe or terminals
V/f control, vector control with/without encoder,servo control with/without encoder
0 ... 300 Hz (V/f control, vector control),0 ... 400 Hz (V/f), 0 ... 650 Hz (servo control)
IP20
SIMATIC ET 200SFrequency converter
IK PI
380 … 480 V 3 AC
0.75 kW,2.2 kW,
4 kW
0 ... VLINE
Induction motors
PROFIBUS, PROFIBUS with PROFIsafe,PROFINET, PROFINET with PROFIsafe, USS (RS 232)
STO, SS1, SLS 1) 2); via PROFIsafe or local
V/f control,vector control with/without encoder
0 ... 650 Hz (V/f control)
IP20
SINAMICS G120DDistributed Drive
D 11.1
380 … 480 V 3 AC
0.75 … 7.5 kW
0 ... VLINE
Induction motors
PROFIBUS, PROFIBUS with PROFIsafe,PROFINET, PROFINET with PROFIsafe
STO, SS1, SLS 1) 2); via PROFIsafe
V/f control, FCC control,vector control with/without encoder
0 ... 650 Hz (V/f control)
IP65
SIMATIC ET 200pro FCFrequency converter
IK PI
380 … 480 V 3 AC
1.1 … 1.5 3) kW
0 ... VLINE
Induction motors
PROFIBUS, PROFIBUS with PROFIsafe,PROFINET, PROFINET with PROFIsafe
STO, SS1, SLS 1) 2); via PROFIsafe or local
V/f control, FCC control,vector control without encoder
0 ... 650 Hz
IP65
SINAMICS S120AC/DC-Drive
PM 21
380 … 480 V 3 AC
1.6 … 107 kW
0 ... VLINE
PROFIBUS, PROFIBUS with PROFIsafe,PROFINET, PROFINET with PROFIsafe, Can open
IP20IP20
SIMATIC ET 200proMotor starters
LV 1; IK PI
Up to 500 V 3 AC
0.2 … 5.5 KW
VLINE
Electromechanical direct starter/reversing starters,electronic direct starter/reversing starters
50/60 Hz
Induction motors
IP65
PROFIBUS, PROFIBUS with PROFIsafe,PROFINET, PROFINET with PROFIsafe
SIMODRIVE POSMO CD/CADrive
DA 65.4
600 V DC (CD),380 … 480 V 3 AC (CA)
0 ... VLINE
Induction motors, synchronous motors,torque motors, linear motors
PROFIBUS
–
Servo control
IP65
0 ... 650 Hz
–
SIRIUS M200DMotor starters
LV 1; IK PI
Up to 500 V 3 AC
0.06 … 5.5 kW
VLINE
Induction motors
AS-Interface, PROFIBUS, PROFINET
Direct, reversing, soft starters
50/60 Hz
IP65
–
Industrial Ethernet Switches,Cables and Plugs
Electrical and/or opticalIndustrial Ethernet networksin linear, star or redundant
ring topology
Industrial Ethernet
IK PI
Electrical (RJ45 or M12) andoptical (glass, PCF or POF FOC)
System connections forSIMATIC S7
Industrial Ethernet, PROFIBUS,AS-Interface
IK PI
Electrical RJ45 and sub-D socket
Connection of SIMATIC S7to various bus system withoptimum communicationsperformance in each case
Passive network components:electrical and optical cablesand plugs, electrical outlets;
SCALANCE X: Industrial Ethernetswitches and Industrial Ethernet
media converters
Communications processorsfor direct connection of
SIMATIC S7-200, S7-300, S7-400
Industrial Wireless LAN
Build-up of reliable andsafe radio communicationwith IWLAN under rough
ambient conditions
Wireless Ethernet communication
IK PI
Industrial Ethernet hybrid socket;RJ45 connection;
external antenna connections
SCALANCE W access pointsand client modules
Network transitions
IWLAN, PROFINET, PROFIBUS,AS-Interface
IK PI; LV 1
Electrical (RJ45 or M12),sub-D socket,
4-pole screw terminals
Build-up a communicationbeyond different bus systems
(also safety-relevant)
Network transitions fromone bus system to another are
implemented using links.Links pass on the data fromone network to the other.
5.2/10.3 kW (CD),5.6 kW (CA)
Busbar trunking systems SIVACON
6300 A
1000 V
255 kA
Up to IP68
LV 1; LV 1 T
Fuse switch disconnectors /switch disconnectorswith/without fuses
16 … 630 A
1000 V
–
–
3-4 poles
SINAMICS G110DDistributed Drive
D 11.1
380 … 500 V 1 AC
0.75 … 7.5 kW
0 ... VLINE
Induction motors
AS-Interface
–
V/f control,FCC (Easy Vector)
0 ... 650 Hz
IP65
–/–
Yes/Yes
PROFINET
–25 … +60 °C
LV 1; IK PI
Dependent on the applied current transformer(x/1 or x/5 applicable)
690 V
100 A for 1 s (on the secondary winding)
–
–
Up to IP65
Intelligent Energy Management for optimized power utilizationand transparency – with SENTRON PAC and the
add-ons SIMATIC PCS 7 powerrate / SIMATIC WinCC powerrate
Fullyenclosed
HMI-devices
ST 80
Devices with completeIP65 protection for use
on support arms or stands(as Touch Panel, Operator
Panel or LCD monitor)
Color
Touch
15/19 inches
Dependent on design PPI/MPI/PROFIBUS/PROFINET
WinCC flexible
Possible
EMERGENCY STOP,EMERGENCY OFF, retrofittable
via extension units
LV 1; LV 70
–
–
Solid shaft with feather key, hollow shaft with feather key,hollow shaft with shrink disk, splined shaft,
shafts with metric and inch dimensions
Solid shaft with feather key,hollow shaft with feather key
Foot-, flange-mounted design,torque arm
Incremental encoders,absolute encoders
0.01 µs with high-performance processors:Celeron M 1.2 GHz; Core2Solo 1.2 GHz;
Core2Duo 1.2 GHz
SINAMICS S110
PM 22
200 … 240 V 1 AC,380 … 480 V 3 AC
0.12 … 0.75 kW (200… 240 V 1 AC),0.37 … 90 kW (380 … 480 V 3 AC)
0 ... VLINE
Induction motors, synchronous motors
PROFIBUS, PROFINET
Servo control
0 … 300 Hz
IP20
Identification
–
–
–
–
–
© Siemens AG 2010
Conveying, rotating, tilting – Solutions for every requirementOverview · April 2010
Answers for industry.
Conveyor technology
www.siemens.com/conveyor-technology
Subject to change without prior noticeOrder No.: 6ZB5711-0AG02-0AA4Dispo 18404BR 0410 3.0 VOG 16 En 3P.8222.13.02Printed in Germany© Siemens AG 2010
Siemens AGIndustry Sector Drive Technologies DivisionIndustry Automation
The information provided in this brochure contains descriptionsor characteristics of performance which in case of actual use do notalways apply as described or which may change as a result offurther development of the products. An obligation to provide therespective characteristics shall only exist if expressly agreed in theterms of contract. Availability and technical specifications aresubject to change without prior notice.All product designations may be trademarks or product names ofSiemens AG or supplier companies whose use by third parties fortheir own purposes could violate the rights of the owners.
© Siemens AG 2010