Page 2: Convair CP15HS Manual

CONTENTSIntroduction......................................1

Safety ..............................................2

Component location.........................3

Installing the exhaust hose ..............4

Control panel ...................................5

Remote control ................................6

Operation......................................7-8

Maintenance ....................................9

Troubleshooting .............................10

Specifications.................................11

Warranty ........................................12

Please read these instructions prior to using the appliance andsave them for future reference.

Waste electrical products must not be disposed of with householdwaste. This product should be taken to your local recycling centre forsafe treatment.

ClimateMaster series Portable Refrigerated Air Conditioneri

®

THANK YOU for choosing a ConvairAir Conditioner. This appliance hasbeen carefully engineered to bring youtrouble-free personal air conditioning.Please read this manual carefully sothat you take full advantage of themany benefits your Convair provides.

This appliance is not intended for use bypersons (including children) with reducedphysical, sensory or mental capabilities,or lack of experience and knowledge,unless they have been given supervisionor instruction in using the appliance by aperson responsible for their safety.

Children should be supervised to ensurethat they do not play with the appliance.Do not place anything through theventilating slots.

Your Convair cooler is a portable airconditioning unit that supplies refrigeratedair to a personal area within a room. It isnot intended to function as a house orroom air conditioner.

Be sure the appliance has been securelyand correctly installed according to theinstallation instructions contained withinthis manual.

Personal Cooling

Energy Saving Tips

Warranty

D

D

D

D

D

Do not locate the air conditioner wherefurniture or other objects can obstruct theair flow.Keep curtains and blinds closed duringthe hottest part of the day.Keep the filters clean.Set the air conditioner to maximumcooling and high fan speed initially, thenadjust to a comfortable setting.Do not wait until the room is excessivelyhot before using the air conditioner.

Convair air conditioners are warrantedagainst faulty manufacture for 2 years afterpurchase. Please refer to page 12 for moredetails on warranty.

SEELEY INTERNATIONAL – OWNER’S MANUAL 1

INTRODUCTION

Page 3: Convair CP15HS Manual

CONTENTSIntroduction......................................1

Safety ..............................................2

Component location.........................3

Installing the exhaust hose ..............4

Control panel ...................................5

Remote control ................................6

Operation......................................7-8

Maintenance ....................................9

Troubleshooting .............................10

Specifications.................................11

Warranty ........................................12

Please read these instructions prior to using the appliance andsave them for future reference.

Waste electrical products must not be disposed of with householdwaste. This product should be taken to your local recycling centre forsafe treatment.

ClimateMaster series Portable Refrigerated Air Conditioneri

®

THANK YOU for choosing a ConvairAir Conditioner. This appliance hasbeen carefully engineered to bring youtrouble-free personal air conditioning.Please read this manual carefully sothat you take full advantage of themany benefits your Convair provides.

This appliance is not intended for use bypersons (including children) with reducedphysical, sensory or mental capabilities,or lack of experience and knowledge,unless they have been given supervisionor instruction in using the appliance by aperson responsible for their safety.

Children should be supervised to ensurethat they do not play with the appliance.Do not place anything through theventilating slots.

Your Convair cooler is a portable airconditioning unit that supplies refrigeratedair to a personal area within a room. It isnot intended to function as a house orroom air conditioner.

Be sure the appliance has been securelyand correctly installed according to theinstallation instructions contained withinthis manual.

Personal Cooling

Energy Saving Tips

Warranty

D

D

D

D

D

Do not locate the air conditioner wherefurniture or other objects can obstruct theair flow.Keep curtains and blinds closed duringthe hottest part of the day.Keep the filters clean.Set the air conditioner to maximumcooling and high fan speed initially, thenadjust to a comfortable setting.Do not wait until the room is excessivelyhot before using the air conditioner.

Convair air conditioners are warrantedagainst faulty manufacture for 2 years afterpurchase. Please refer to page 12 for moredetails on warranty.

SEELEY INTERNATIONAL – OWNER’S MANUAL 1

INTRODUCTION

Page 4: Convair CP15HS Manual

General SafetyFor indoor use only.

Ensure the appliance has been installed inaccordance with national wiring regulations.

Transport the air conditioner in anupright position only, or leave it in anupright position for at least 2 hoursbefore use (Fig 1).

Use only in the upright position on a flatlevel surface and at least 50cm from anyobjects.

Do not place objects on the air conditioner,or through the ventilating slots or restrict theair inlets & outlets (Fig 2).

Closely supervise any children and petswhen the air conditioner is in use.

Electrical Safety

Do not store or operate the appliance nearany flammable substances.

During operation, water will collect in thebottom tank of the air conditioner. Becareful when moving the unit to preventwater from spilling.

Electrical Safety (cont)

Caution! before connecting theelectrical power cord to a power outlet,check that the air conditioner voltage isthe same as your power supply (refer tothe rating label located on the back of theunit - refer Fig 4). Ensure the power supplyis correctly earthed and rated.

Plug the air conditioner directly into aproperly installed power outlet. Never usean extension cord, double adaptor or multipower outlet board to run this airconditioner.

Do not pull the unit along by the powercord or place the power cord near asource of heat. Always unroll the powercord completely before use.

Switch off and unplug when not in use.

Do not use in humid environments such asbathrooms, laundries or other steamy orwet areas.

Do not touch or operate the air conditionerwith wet or damp hands or when standingbarefoot.

If the power supply cord is damaged itmust be replaced by the manufacturer, aservice agent or similarly qualified personsin order to avoid a hazard.

1

2

2 ClimateMaster series Portable Refrigerated Air Conditioner

®

SAFETY

4

3

RemoteControl

Air Outlet

Handle

Remote SensorDisplay Panel

Control Panel

Air Filter

Drain

Air Intake(active carbonfilter to be fittedhere)

Air Intake(side panel)

Air Intake(side panel)

PowerCord

Exhaust AirOutlet

Exhaust Hose

Active Carbon

Filter

Window Attachment

Exhaust Fitting(window end)

RatingLabel

Cord StorageDoor

COMPONENT LOCATION

SEELEY INTERNATIONAL – OWNER’S MANUAL 3

Page 5: Convair CP15HS Manual

General SafetyFor indoor use only.

Ensure the appliance has been installed inaccordance with national wiring regulations.

Transport the air conditioner in anupright position only, or leave it in anupright position for at least 2 hoursbefore use (Fig 1).

Use only in the upright position on a flatlevel surface and at least 50cm from anyobjects.

Do not place objects on the air conditioner,or through the ventilating slots or restrict theair inlets & outlets (Fig 2).

Closely supervise any children and petswhen the air conditioner is in use.

Electrical Safety

Do not store or operate the appliance nearany flammable substances.

During operation, water will collect in thebottom tank of the air conditioner. Becareful when moving the unit to preventwater from spilling.

Electrical Safety (cont)

Caution! before connecting theelectrical power cord to a power outlet,check that the air conditioner voltage isthe same as your power supply (refer tothe rating label located on the back of theunit - refer Fig 4). Ensure the power supplyis correctly earthed and rated.

Plug the air conditioner directly into aproperly installed power outlet. Never usean extension cord, double adaptor or multipower outlet board to run this airconditioner.

Do not pull the unit along by the powercord or place the power cord near asource of heat. Always unroll the powercord completely before use.

Switch off and unplug when not in use.

Do not use in humid environments such asbathrooms, laundries or other steamy orwet areas.

Do not touch or operate the air conditionerwith wet or damp hands or when standingbarefoot.

If the power supply cord is damaged itmust be replaced by the manufacturer, aservice agent or similarly qualified personsin order to avoid a hazard.

1

2

2 ClimateMaster series Portable Refrigerated Air Conditioner

®

SAFETY

4

3

RemoteControl

Air Outlet

Handle

Remote SensorDisplay Panel

Control Panel

Air Filter

Drain

Air Intake(active carbonfilter to be fittedhere)

Air Intake(side panel)

Air Intake(side panel)

PowerCord

Exhaust AirOutlet

Exhaust Hose

Active Carbon

Filter

Window Attachment

Exhaust Fitting(window end)

RatingLabel

Cord StorageDoor

COMPONENT LOCATION

SEELEY INTERNATIONAL – OWNER’S MANUAL 3

Page 6: Convair CP15HS Manual

Assembling the exhaust hose (Fig 5,6)Step 1:

Step 2:

Step 3:

Fit the exhaust hose to the rearpanel outlet by rotating the hose in aclockwise direction. Fit the window adaptoronto the hose by rotating the adaptor in aclockwise direction.

Screw the round window adaptorinto position on the window attachment withthe screws (4) provided.

Open the window and fit theadjustable window attachment. Extend theattachment as required and lock into placewith the screw (1) provided. Ensure theoutlet is not obscured. The windowattachment can be installed horizontally orvertically, depending on the window type.

Note!

Note!

The minimum distance requiredfrom the operating air conditioner toany obstructing objects or walls is50cm (Fig 6).

Keep the exhaust hose as short andstraight as possible and minimisekinks. This will maximise the coolingperformance.

Don’t use extension pieces for theexhaust pipe as this will reduce thecooling performance and possiblyresult in damage to the air conditioner.

Hot air and possibly mist will beemitted from the exhaust hose.

It is critical to the cooler’sperformance that the hot exhaust air iscompletely removed from the spacebeing cooled.

50cm

6

INSTALLING THE EXHAUST

5

4

®

ClimateMaster series Portable Refrigerated Air Conditioner

7

CONTROL PANEL

Ion / TiO

button2 Timer Set

buttonPower ON / OFF

buttonMode Select

buttonTemperature adjust

buttons

Fan Speedcontrol button

Press to cycle the fanspeed between low,

medium and high

Press to activateion generator and

TiO lamp

(only models CM12WXand CM15WX)

2

Press to enter thetimer setting mode

and time

Sleepbutton

Press to enter thesleep mode

Press to turn theair conditioner on

and off

Press to cycle fromCooling, Dehumidifying,

Fan and

modes.

Heating(CP12HS,CP15HS andCM15HW only)

Press to increase,to decrease the

set temperature

r

s

To avoid damage to the control panel, do not operate with sharp objects.NOTE!

DISPLAY PANEL

Cooling ModeIndicator

Set TemperatureDisplay

DehumidifyingMode Indicator

Fan ModeIndicator

Sleep ModeIndicator

TimerIndicator

Ion / TiO Indicator

(only models CM12WXand CM15WX)

2

Fan SpeedIndicator

Low

Medium

High

Water TankFull Indicator

Heating ModeIndicator

(only modelsCP12HS, CP15HS

and CM15HW)

8

SEELEY INTERNATIONAL – OWNER’S MANUAL 5

Page 7: Convair CP15HS Manual

Assembling the exhaust hose (Fig 5,6)Step 1:

Step 2:

Step 3:

Fit the exhaust hose to the rearpanel outlet by rotating the hose in aclockwise direction. Fit the window adaptoronto the hose by rotating the adaptor in aclockwise direction.

Screw the round window adaptorinto position on the window attachment withthe screws (4) provided.

Open the window and fit theadjustable window attachment. Extend theattachment as required and lock into placewith the screw (1) provided. Ensure theoutlet is not obscured. The windowattachment can be installed horizontally orvertically, depending on the window type.

Note!

Note!

The minimum distance requiredfrom the operating air conditioner toany obstructing objects or walls is50cm (Fig 6).

Keep the exhaust hose as short andstraight as possible and minimisekinks. This will maximise the coolingperformance.

Don’t use extension pieces for theexhaust pipe as this will reduce thecooling performance and possiblyresult in damage to the air conditioner.

Hot air and possibly mist will beemitted from the exhaust hose.

It is critical to the cooler’sperformance that the hot exhaust air iscompletely removed from the spacebeing cooled.

50cm

6

INSTALLING THE EXHAUST

5

4

®

ClimateMaster series Portable Refrigerated Air Conditioner

7

CONTROL PANEL

Ion / TiO

button2 Timer Set

buttonPower ON / OFF

buttonMode Select

buttonTemperature adjust

buttons

Fan Speedcontrol button

Press to cycle the fanspeed between low,

medium and high

Press to activateion generator and

TiO lamp

(only models CM12WXand CM15WX)

2

Press to enter thetimer setting mode

and time

Sleepbutton

Press to enter thesleep mode

Press to turn theair conditioner on

and off

Press to cycle fromCooling, Dehumidifying,

Fan and

modes.

Heating(CP12HS,CP15HS andCM15HW only)

Press to increase,to decrease the

set temperature

r

s

To avoid damage to the control panel, do not operate with sharp objects.NOTE!

DISPLAY PANEL

Cooling ModeIndicator

Set TemperatureDisplay

DehumidifyingMode Indicator

Fan ModeIndicator

Sleep ModeIndicator

TimerIndicator

Ion / TiO Indicator

(only models CM12WXand CM15WX)

2

Fan SpeedIndicator

Low

Medium

High

Water TankFull Indicator

Heating ModeIndicator

(only modelsCP12HS, CP15HS

and CM15HW)

8

SEELEY INTERNATIONAL – OWNER’S MANUAL 5

Page 8: Convair CP15HS Manual

If there are two of the same airconditioners installed, they cannot becontrolled separately. When you operateeither remote, it will turn on both airconditioners if they are both within signalrange (6 metres).

Don’t let the remote control drop ontohard surfaces or be subjected to suddenshocks in any way. The warranty does notcover misuse or accidental damage.

Don’t place the remote control in directsunlight, or near extremes of temperature.This will affect the control’s temperaturereading.

Don’t allow the remote control to get wet.

Don’t place near strong electromagneticwaves.

Don’t mix old and new batteries ! If theremote control will not be used for a longtime, remove the batteries to avoidcorrosion.

Care of your remote control

Preparation before operation

During Operation

Remove the battery cover and insert newbatteries

.

Remove the batteries and replace with newones. If this does not solve the problemcontact your nearest service centre foradvice.

(AAA), making sure the + and - arematching the compartment markings (Fig10)

If the remote control will not operate the airconditioner, the batteries may need to bereplaced.

The air conditioner must be plugged inand switched on for the remote control tooperate the air conditioner. To use, point atthe signal receiving window on the frontpanel and press the remote button. The airconditioner will “beep” when a signal hasbeen received. If there is no beep, press theremote button again, ensuring it is withinrange (6 metres) of the air conditioner.

Note!

!NOTE:WASTE BATTERIES SHOULD

BE DISPOSED OF CORRECTLY

REMOTE CONTROL

6

®

9Signaltransmission point

Temperatureadjust buttons

Ion / TiO button2

(only active formodels CM12WXand CM15WX)

Sleep mode button

Fan speedadjust buttons Mode buttons

(Cool-Dehumidify-Fan-Heat)

Timer on / adjustbutton

Power ON / OFFbutton Battery

compartment

Battery cover

10

ClimateMaster series Portable Refrigerated Air Conditioner

Starting the air conditioner

Step 1: Ensure the cooler is plugged inand switched on.

Step 2:

Step 3:

Cooling mode

Dehumidifying mode

Fan mode

Heat mode -

Step 4:

!

Step 5:

Press the ON/OFF button on theremote control or ON/OFF button on thecontrol panel to start the air conditioner.

Press the MODE button onthe control panel or remote control toselect the desired operating mode (Fig 7 &11):

- refrigerated

cooling (all models)

- forextracting moisture from the air

- Fan only operation

(no cooling)

reverse cycleheating (CP12HS, CP15HS andCM15HW only)

Press / on the control panelor on the remote control to select thedesired operating ‘set’ temperature.

In Cooling mode, cooling will occur if theset temperature is less than the roomtemperature.In Heating mode, heating will occur if theset temperature is greater than the roomtemperature.

Do not set the cooling temperaturetoo low. This will consume more power.24°C is the recommended settemperature, with high fan speed.

Changing the set temperature willhave no effect in DEHUMIDIFYING or FANmodes.

Press the FAN SPEED buttonon the control panel or remote control toadjust the fan speed. Each press willcycle the fan speed through low, medium& high.

r s

The set temperature range is 16°C-31°C

Tip

Note!

Step.2

Step.8

Step.3Step.5

Step.4

Step.7

Step.6

OPERATION

11

Note!

Important!

the fan speed is automatically set tolow in dehumidifying and sleep modes.In Cooling & Heating modes, the fan willcontinue to run even when the compressorhas cycled off.

During heating mode the unitmay enter a defrost cycle. When thisoccurs, the compressor will stop and the fanwill continue to run. This is a normalfunction for all reverse cycle air conditioners.The compressor will re-start and normalheating operation will recommence whenthe defrost cycle is complete.During cooling and heating mode, water willcollect in the air conditioner’s tank. Incooling mode this water is recirculated andsome will be exhausted out with the hot air,but will slowly fill up the tank. This occursmore quickly in humid conditions. There isno recirculation in heating mode. If the tankshould fill, the ‘water full’ symbol willflash on the control display, the unit will‘beep’ 15 times and then shut down. Thecooler cannot be restarted until the watertank is drained. Refer to the Maintenancesection for draining the tank should thisoccur.

SEELEY INTERNATIONAL – OWNER’S MANUAL 7

Page 9: Convair CP15HS Manual

If there are two of the same airconditioners installed, they cannot becontrolled separately. When you operateeither remote, it will turn on both airconditioners if they are both within signalrange (6 metres).

Don’t let the remote control drop ontohard surfaces or be subjected to suddenshocks in any way. The warranty does notcover misuse or accidental damage.

Don’t place the remote control in directsunlight, or near extremes of temperature.This will affect the control’s temperaturereading.

Don’t allow the remote control to get wet.

Don’t place near strong electromagneticwaves.

Don’t mix old and new batteries ! If theremote control will not be used for a longtime, remove the batteries to avoidcorrosion.

Care of your remote control

Preparation before operation

During Operation

Remove the battery cover and insert newbatteries

.

Remove the batteries and replace with newones. If this does not solve the problemcontact your nearest service centre foradvice.

(AAA), making sure the + and - arematching the compartment markings (Fig10)

If the remote control will not operate the airconditioner, the batteries may need to bereplaced.

The air conditioner must be plugged inand switched on for the remote control tooperate the air conditioner. To use, point atthe signal receiving window on the frontpanel and press the remote button. The airconditioner will “beep” when a signal hasbeen received. If there is no beep, press theremote button again, ensuring it is withinrange (6 metres) of the air conditioner.

Note!

!NOTE:WASTE BATTERIES SHOULD

BE DISPOSED OF CORRECTLY

REMOTE CONTROL

6

®

9Signaltransmission point

Temperatureadjust buttons

Ion / TiO button2

(only active formodels CM12WXand CM15WX)

Sleep mode button

Fan speedadjust buttons Mode buttons

(Cool-Dehumidify-Fan-Heat)

Timer on / adjustbutton

Power ON / OFFbutton Battery

compartment

Battery cover

10

ClimateMaster series Portable Refrigerated Air Conditioner

Starting the air conditioner

Step 1: Ensure the cooler is plugged inand switched on.

Step 2:

Step 3:

Cooling mode

Dehumidifying mode

Fan mode

Heat mode -

Step 4:

!

Step 5:

Press the ON/OFF button on theremote control or ON/OFF button on thecontrol panel to start the air conditioner.

Press the MODE button onthe control panel or remote control toselect the desired operating mode (Fig 7 &11):

- refrigerated

cooling (all models)

- forextracting moisture from the air

- Fan only operation

(no cooling)

reverse cycleheating (CP12HS, CP15HS andCM15HW only)

Press / on the control panelor on the remote control to select thedesired operating ‘set’ temperature.

In Cooling mode, cooling will occur if theset temperature is less than the roomtemperature.In Heating mode, heating will occur if theset temperature is greater than the roomtemperature.

Do not set the cooling temperaturetoo low. This will consume more power.24°C is the recommended settemperature, with high fan speed.

Changing the set temperature willhave no effect in DEHUMIDIFYING or FANmodes.

Press the FAN SPEED buttonon the control panel or remote control toadjust the fan speed. Each press willcycle the fan speed through low, medium& high.

r s

The set temperature range is 16°C-31°C

Tip

Note!

Step.2

Step.8

Step.3Step.5

Step.4

Step.7

Step.6

OPERATION

11

Note!

Important!

the fan speed is automatically set tolow in dehumidifying and sleep modes.In Cooling & Heating modes, the fan willcontinue to run even when the compressorhas cycled off.

During heating mode the unitmay enter a defrost cycle. When thisoccurs, the compressor will stop and the fanwill continue to run. This is a normalfunction for all reverse cycle air conditioners.The compressor will re-start and normalheating operation will recommence whenthe defrost cycle is complete.During cooling and heating mode, water willcollect in the air conditioner’s tank. Incooling mode this water is recirculated andsome will be exhausted out with the hot air,but will slowly fill up the tank. This occursmore quickly in humid conditions. There isno recirculation in heating mode. If the tankshould fill, the ‘water full’ symbol willflash on the control display, the unit will‘beep’ 15 times and then shut down. Thecooler cannot be restarted until the watertank is drained. Refer to the Maintenancesection for draining the tank should thisoccur.

SEELEY INTERNATIONAL – OWNER’S MANUAL 7

Page 10: Convair CP15HS Manual

8

®

ClimateMaster series Portable Refrigerated Air Conditioner

D

B

OPERATION cont.

Air Conditioner Features

Timer Function

Step 6:

Step 7:

Step 8: Setting the timer

Your air conditioner has a SLEEPmode, activated by pressing the button onthe control panel or remote control.SLEEP mode will change the fan speed tolow and increase (for cooling mode) ordecrease (for heating mode) the settemperature by 1°C each hour for 2 hours.No further change will occur after the 2ndhour.

To improve air cleanliness, yourcooler may be equipped with an activecarbon filter, negative ion generator andTiO lamp (models CM12WX, CM15WX

only).Fit the active carbon filter into the upperrear filter frame as shown (Fig 12).

A - remove side filter from unitB - remove upper rear filterC - unclip the frame from the rear filterD - insert the active carbon filter and clipthe frame back into place.

Reassemble all filters back into the unit,then press the Ion/TiO button on the

control panel or remote control to activatethis feature.

The air conditioner is fitted with a timerfunction. This can be set up to 24 hours inadvance. To use this function, the coolermust be plugged in and ready to operate.

With the air conditioner ON, press theTIMER button on the remote control orcontrol panel. The control panel displaywill flash and show the time setting. Pressthe TIMER button to increase the time in 1hour increments from 1 - 24 hrs. After 5seconds the display will revert to the SETtemperature.

2

2

12

A

C

When the air conditioner is OFF (but stillplugged in), repeat the above to set the ONtime. The air conditioner will start up with thelast settings used.

When the air conditioner is working, onlythe TIMER OFF can be set. When the airconditioner is off, only the TIMER ON can beset.

To cancel the timer, press and hold the TIMERbutton on the control panel for 3 seconds or setthe time to using the remote control. TheTIMER indicator will stop glowing.

Note!

How to cancel the timer

0

SEELEY INTERNATIONAL – OWNER’S MANUAL 9

Draining the Air Conditioner

To drain the air conditioner, place it over adrain point before unscrewing the cap andremoving the drain plug, as water will flow outas soon as the plug is removed.Remove the plug at the bottom rear of theappliance and allow the tank to completelydrain (Fig 13B).

Note! Always replace the drain plugimmediately after draining.

Always disconnect the air conditioner from the electricity mains before cleaning ordraining.

To maximize the efficiency of the air conditioner, clean regularly.

Never operate the air conditioner without the filters.

Cleaning the housing

Cleaning the filters

Note!

Use a soft, damp cloth to wipe the body clean.Never use aggressive chemicals, spirits, detergents, chemically treated cloths, or othercleansing solutions. These substances could possibly damage the cabinet

Use a vacuum cleaner or tap the filter lightly to remove loose dust and dirt and then rinseunder running water (no hotter than 40°C).Dry thoroughly before replacing.Take care to replace the filters back into the slots in the cooler.

.

Remove the filters as shown (Fig 13A).

End of season storage:

Drain any water from the unit.

Operate the unit in fan only mode for a few hours, to thoroughly dry the inside.

Clean or change the filters.

Replace in the original carton or cover for storage.

Unplug and carefully store the power cord and plug end behind the cord storagedoor (Fig 13C).

MAINTENANCE

B

C

13 ARemove all filters (5 total)from the air conditionerand clean every 2 weeks.

Page 11: Convair CP15HS Manual

8

®

ClimateMaster series Portable Refrigerated Air Conditioner

D

B

OPERATION cont.

Air Conditioner Features

Timer Function

Step 6:

Step 7:

Step 8: Setting the timer

Your air conditioner has a SLEEPmode, activated by pressing the button onthe control panel or remote control.SLEEP mode will change the fan speed tolow and increase (for cooling mode) ordecrease (for heating mode) the settemperature by 1°C each hour for 2 hours.No further change will occur after the 2ndhour.

To improve air cleanliness, yourcooler may be equipped with an activecarbon filter, negative ion generator andTiO lamp (models CM12WX, CM15WX

only).Fit the active carbon filter into the upperrear filter frame as shown (Fig 12).

A - remove side filter from unitB - remove upper rear filterC - unclip the frame from the rear filterD - insert the active carbon filter and clipthe frame back into place.

Reassemble all filters back into the unit,then press the Ion/TiO button on the

control panel or remote control to activatethis feature.

The air conditioner is fitted with a timerfunction. This can be set up to 24 hours inadvance. To use this function, the coolermust be plugged in and ready to operate.

With the air conditioner ON, press theTIMER button on the remote control orcontrol panel. The control panel displaywill flash and show the time setting. Pressthe TIMER button to increase the time in 1hour increments from 1 - 24 hrs. After 5seconds the display will revert to the SETtemperature.

2

2

12

A

C

When the air conditioner is OFF (but stillplugged in), repeat the above to set the ONtime. The air conditioner will start up with thelast settings used.

When the air conditioner is working, onlythe TIMER OFF can be set. When the airconditioner is off, only the TIMER ON can beset.

To cancel the timer, press and hold the TIMERbutton on the control panel for 3 seconds or setthe time to using the remote control. TheTIMER indicator will stop glowing.

Note!

How to cancel the timer

0

SEELEY INTERNATIONAL – OWNER’S MANUAL 9

Draining the Air Conditioner

To drain the air conditioner, place it over adrain point before unscrewing the cap andremoving the drain plug, as water will flow outas soon as the plug is removed.Remove the plug at the bottom rear of theappliance and allow the tank to completelydrain (Fig 13B).

Note! Always replace the drain plugimmediately after draining.

Always disconnect the air conditioner from the electricity mains before cleaning ordraining.

To maximize the efficiency of the air conditioner, clean regularly.

Never operate the air conditioner without the filters.

Cleaning the housing

Cleaning the filters

Note!

Use a soft, damp cloth to wipe the body clean.Never use aggressive chemicals, spirits, detergents, chemically treated cloths, or othercleansing solutions. These substances could possibly damage the cabinet

Use a vacuum cleaner or tap the filter lightly to remove loose dust and dirt and then rinseunder running water (no hotter than 40°C).Dry thoroughly before replacing.Take care to replace the filters back into the slots in the cooler.

.

Remove the filters as shown (Fig 13A).

End of season storage:

Drain any water from the unit.

Operate the unit in fan only mode for a few hours, to thoroughly dry the inside.

Clean or change the filters.

Replace in the original carton or cover for storage.

Unplug and carefully store the power cord and plug end behind the cord storagedoor (Fig 13C).

MAINTENANCE

B

C

13 ARemove all filters (5 total)from the air conditionerand clean every 2 weeks.

Page 12: Convair CP15HS Manual

Never try to dismantle the air conditioner yourself.In case of problems that cannot be fixed by using the above guide, or if service on your air conditioner is required,

please contact your dealer or designated service agent.

TROUBLESHOOTING

10

®

Problem Check

The air conditioner doesnot run.

Is the air conditioner plugged in ?

Is there a power failure?

Is the "WATER FULL" error code flashing?Drain the tank as shown (Fig 13).

Is the room temperature below the set temperature?

The air conditioner has littleeffect (firstly ensure that theroom being cooled is not toolarge for the stated capacityof the air conditioner).

Is there direct sunshine? Remember to close curtainsblinds.or

Are windows or doors open?

More people in the room will generate more heat.

Is there something in the room producing excessiveheat?

Is the exhaust fitted correctly or obstructed? Allexhaust air needs to be completely removed fromthe room.

The air conditioner is not ascool as it once was.

Are the filters dusty or dirty, restricting the airflow?

Is the air inlet or outlet blocked?

Is the room temperature below the set temperature?

The air conditioner is toonoisy.

Is the air conditioner positioned unevenly, so as tocreate vibration?

Is the floor beneath the air conditioner uneven?

It is possible that the overheat protection for thecompressor is on. Wait for it to reset.

Note: when changing between different modes(cooling to fan or heating mode etc) the compressorwill turn off. A 3 minute delay will occur before thecompressor will turn on again.

The compressor will not run.

ClimateMaster series Portable Refrigerated Air Conditioner

SEELEY INTERNATIONAL - CLIMATEMASTER PORTABLE AIR CONDITIONER

CM12W, CM12WX CM15HW, CP15HSCP12HS CM15WX, CP15W

Personal Cooling Personal CoolingPersonal Cooling & Heating Personal Cooling & Heating

3,500 (12,000 Btu/hr) 4,400 (15,000 Btu/hr)3,500 (12,000 Btu/hr) 4,400 (15,000 Btu/hr)

- -3,500 (12,000 Btu/hr) 4,400 (15,000 Btu/hr)

1.2 1.41.2 1.4

450 500450 500

£ 55 £ 57£ 55 £ 57

220-240 V ~, 50 Hz 220-240 V ~, 50 Hz220-240 V ~, 50 Hz 220-240 V ~, 50 Hz

1380 16801380 1680

3.15 A / 250V 3.15 A / 250V3.15 A / 250V 3.15 A / 250V

R410A / 0.51 R410A / 0.56R410A / 0.51 R410A / 0.56

3.2 3.23.2 3.2

0.8 0.80.8 0.8

IP20 IP20IP20 IP20

31 3231 32

420 / 400 / 840 420 / 400 / 840420 / 400 / 840 420 / 400 / 840

Model(s)

Function

Cooling Capacity (Watts) †

Heating Capacity (Watts) †

Dehumidifying Capacity (L/hr)

Air Flow Volume (m / hr)3

Noise Level - Sound Pressure (dB(A))

Power Supply

Input Power (Watts)

Fuse Type

Refrigerant Type / Charge (kg)

High Side Pressure - Maximum (MPa)

Low Side Pressure - Maximum (MPa)

Water Ingress Protection Rating

Weight (kg)

Dimensions (mm)(width / depth / height)

†Based on manufacturer's test results using the Air Enthalpy method

SPECIFICATIONS

- - - REVERSE CYCLE ONLY

NEGATIVE ION / UV LAMP OPTIONAL

SEELEY INTERNATIONAL – OWNER’S MANUAL 11

Page 13: Convair CP15HS Manual

Never try to dismantle the air conditioner yourself.In case of problems that cannot be fixed by using the above guide, or if service on your air conditioner is required,

please contact your dealer or designated service agent.

TROUBLESHOOTING

10

®

Problem Check

The air conditioner doesnot run.

Is the air conditioner plugged in ?

Is there a power failure?

Is the "WATER FULL" error code flashing?Drain the tank as shown (Fig 13).

Is the room temperature below the set temperature?

The air conditioner has littleeffect (firstly ensure that theroom being cooled is not toolarge for the stated capacityof the air conditioner).

Is there direct sunshine? Remember to close curtainsblinds.or

Are windows or doors open?

More people in the room will generate more heat.

Is there something in the room producing excessiveheat?

Is the exhaust fitted correctly or obstructed? Allexhaust air needs to be completely removed fromthe room.

The air conditioner is not ascool as it once was.

Are the filters dusty or dirty, restricting the airflow?

Is the air inlet or outlet blocked?

Is the room temperature below the set temperature?

The air conditioner is toonoisy.

Is the air conditioner positioned unevenly, so as tocreate vibration?

Is the floor beneath the air conditioner uneven?

It is possible that the overheat protection for thecompressor is on. Wait for it to reset.

Note: when changing between different modes(cooling to fan or heating mode etc) the compressorwill turn off. A 3 minute delay will occur before thecompressor will turn on again.

The compressor will not run.

ClimateMaster series Portable Refrigerated Air Conditioner

SEELEY INTERNATIONAL - CLIMATEMASTER PORTABLE AIR CONDITIONER

CM12W, CM12WX CM15HW, CP15HSCP12HS CM15WX, CP15W

Personal Cooling Personal CoolingPersonal Cooling & Heating Personal Cooling & Heating

3,500 (12,000 Btu/hr) 4,400 (15,000 Btu/hr)3,500 (12,000 Btu/hr) 4,400 (15,000 Btu/hr)

- -3,500 (12,000 Btu/hr) 4,400 (15,000 Btu/hr)

1.2 1.41.2 1.4

450 500450 500

£ 55 £ 57£ 55 £ 57

220-240 V ~, 50 Hz 220-240 V ~, 50 Hz220-240 V ~, 50 Hz 220-240 V ~, 50 Hz

1380 16801380 1680

3.15 A / 250V 3.15 A / 250V3.15 A / 250V 3.15 A / 250V

R410A / 0.51 R410A / 0.56R410A / 0.51 R410A / 0.56

3.2 3.23.2 3.2

0.8 0.80.8 0.8

IP20 IP20IP20 IP20

31 3231 32

420 / 400 / 840 420 / 400 / 840420 / 400 / 840 420 / 400 / 840

Model(s)

Function

Cooling Capacity (Watts) †

Heating Capacity (Watts) †

Dehumidifying Capacity (L/hr)

Air Flow Volume (m / hr)3

Noise Level - Sound Pressure (dB(A))

Power Supply

Input Power (Watts)

Fuse Type

Refrigerant Type / Charge (kg)

High Side Pressure - Maximum (MPa)

Low Side Pressure - Maximum (MPa)

Water Ingress Protection Rating

Weight (kg)

Dimensions (mm)(width / depth / height)

†Based on manufacturer's test results using the Air Enthalpy method

SPECIFICATIONS

- - - REVERSE CYCLE ONLY

NEGATIVE ION / UV LAMP OPTIONAL

SEELEY INTERNATIONAL – OWNER’S MANUAL 11

Page 14: Convair CP15HS Manual

WARRANTY WARRANTY cont.

In this warranty:

or us means Seeley International Pty Ltd ABN 23 054 687 035, and our contact details are set outat the end of this warranty;

means you, the original end-user purchaser of the Goods;

means the authorised distributor or retailer of the Goods that sold you the Goods in Australia;and

means the product, unit, appliance or equipment which was accompanied by this warranty andpurchased in Australia.

Our Goods come with guarantees that cannot be excluded under the Australian Consumer Law. Youare entitled to a replacement or refund for a major failure and for compensation for any otherreasonably foreseeable loss or damage. You are also entitled to have the Goods repaired or replacedif the Goods fail to be of acceptable quality and the failure does not amount to a major failure.

In addition to any rights and remedies that You may have under the Australian Consumer Law or anyother law, subject to the terms of this warranty, We provide the following warranty:

1. If, during the first 24 months from the date of first retail purchase ( ), the Goodsupon examination prove defective by reason of improper workmanship or material, We will repairat our nearest service centre or replace (at our option), the product or any part thereof withoutcharge. Should we deem in our absolute discretion to replace the Goods, we may substitute anysimilar good even if it is not on our current price/equipment list. Further, Goods presented for repairmay be replaced by refurbished goods of the same type rather than being repaired. Refurbishedparts may be used to repair the Goods.

2. We are under no obligation to repair or replace the Goods under clause 1 if the Goods have notbeen used only for personal, domestic or household purposes or have not been operated andmaintained in accordance with the instructions in the Owner's Manual. The addition of any thirdparty device or the removal or the alteration of any of our components will void this warranty. Inaddition, the warranty granted under clause 1 does not apply to:

Consumable components such as filters,Adjustments necessary due to misuse of the cooler,Normal user maintenance,Setting of controls,Transit damage, orDamage caused by user misuse, tampering, or failure to observe the care and specialprovisions in the instructions.

3. The warranty granted under clause 1 is limited to repair or replacement only. As far as the lawpermits, We will not be liable for any consequential loss suffered through, or resulting from, the nonoperation, or ineffective operation of the Goods. The warranty granted under clause 1 does notcover damage to the Goods or other loss resulting from acts of God.

4. We are not responsible in any way for any failure and/or inadequate performance of the Goodswhich arises from or is connected to the use in the Goods of non-genuine spare parts. We stronglyrecommend that only spare parts supplied or approved by us are used in the Goods.

We

You

Supplier

Goods

Warranty Period

······

5. No other person, firm or corporation is authorised by us to offer or give on our behalf any other orgreater warranty than that given under this warranty. The benefits conferred by this warranty are infavour of You and any person deriving title to the Goods through or under such person and areintended to be separate from and additional to all other rights and remedies that they may have inlaw in respect of the Goods.

6.

(a) either:(i) contact us within the Warranty Period on: 1300 650 644;or(ii) log a claim on our website www.seeleyinternational.com within the Warranty Period;

and(b) return the Goods to your nearest service centre (or to us at the address below) by prepaid

freight within the Warranty Period, together with (i) the legible and unmodified proof ofpurchase, which clearly indicates the name and address of the original retailer, the date andplace of purchase, the product name or other product serial number, and (ii) a copy of thecompleted Warranty Information below. (If you choose to return the Goods to us, there is anadditional requirement - they will also need to be accompanied by a covering letter whichstates your name and address and daytime telephone number, and the model and serialnumber of the goods.)

8. This warranty does not cover the cost of claiming under the warranty, it is your responsibility tocover all forwarding and return freight costs incurred in sending the Goods to and from yournearest service centre or us.

9. This warranty is only valid and enforceable in Australia.

Our liability under this warranty is limited to the extent permitted by law. That is, to the extent that it isfair and reasonable, if the Goods are not of a kind ordinarily acquired for personal, domestic orhousehold use or consumption, your remedies associated with any failure or defect of the Product willbe limited to:

(a) the replacement of the Goods or the supply of equivalent goods;(b) the repair of the Goods;(c) the payment of the cost of replacing the Goods or of acquiring equivalent goods;(d) the payment of the cost of having the Goods repairedand subject to the terms

and conditions included in this warranty.

To ensure that service either pursuant to the above warranty or otherwise is readily available, we haveestablished in all States authorised service centres, which are available to deal with servicerequirements.

For further information about your nearest service centre and other enquiries please call our ServiceCentre on:

If it is less than fifteen (15) days from the date of purchase of the Goods, in order to claim under thewarranty granted under clause 1 You must return the Goods to the Supplier at the place ofpurchase together with the proof of purchase.

7. If it is more than fifteen (15) days after the date of purchase, in order to claim under the warrantygranted under clause 1 You must:

1300 650 644Please retain your receipt as proof of purchase. Every request for warranty must beaccompanied by proof of purchase.

:

Complete the following for your records:

: ......................................................................................................................................

Serial Number:

Date purchased

Product

Purchased from

Convair CLIMATE MASTER

: ....../....../......

Model: CM12W CM12WX CP12HS

CM15WX CM15HW CP15W CP15HS

1 1 1

1 1 1 1

Service DepartmentSeeley International Pty Ltd112 O'Sullivan Beach Road, Lonsdale, South Australia 5160Customer service centre in Australia: 1300 650 644Website: www.seeleyinternational.com

SEELEY INTERNATIONAL – OWNER’S MANUAL 13ClimateMaster series Portable Refrigerated Air Conditioner12

®

Page 15: Convair CP15HS Manual

WARRANTY WARRANTY cont.

In this warranty:

or us means Seeley International Pty Ltd ABN 23 054 687 035, and our contact details are set outat the end of this warranty;

means you, the original end-user purchaser of the Goods;

means the authorised distributor or retailer of the Goods that sold you the Goods in Australia;and

means the product, unit, appliance or equipment which was accompanied by this warranty andpurchased in Australia.

Our Goods come with guarantees that cannot be excluded under the Australian Consumer Law. Youare entitled to a replacement or refund for a major failure and for compensation for any otherreasonably foreseeable loss or damage. You are also entitled to have the Goods repaired or replacedif the Goods fail to be of acceptable quality and the failure does not amount to a major failure.

In addition to any rights and remedies that You may have under the Australian Consumer Law or anyother law, subject to the terms of this warranty, We provide the following warranty:

1. If, during the first 24 months from the date of first retail purchase ( ), the Goodsupon examination prove defective by reason of improper workmanship or material, We will repairat our nearest service centre or replace (at our option), the product or any part thereof withoutcharge. Should we deem in our absolute discretion to replace the Goods, we may substitute anysimilar good even if it is not on our current price/equipment list. Further, Goods presented for repairmay be replaced by refurbished goods of the same type rather than being repaired. Refurbishedparts may be used to repair the Goods.

2. We are under no obligation to repair or replace the Goods under clause 1 if the Goods have notbeen used only for personal, domestic or household purposes or have not been operated andmaintained in accordance with the instructions in the Owner's Manual. The addition of any thirdparty device or the removal or the alteration of any of our components will void this warranty. Inaddition, the warranty granted under clause 1 does not apply to:

Consumable components such as filters,Adjustments necessary due to misuse of the cooler,Normal user maintenance,Setting of controls,Transit damage, orDamage caused by user misuse, tampering, or failure to observe the care and specialprovisions in the instructions.

3. The warranty granted under clause 1 is limited to repair or replacement only. As far as the lawpermits, We will not be liable for any consequential loss suffered through, or resulting from, the nonoperation, or ineffective operation of the Goods. The warranty granted under clause 1 does notcover damage to the Goods or other loss resulting from acts of God.

4. We are not responsible in any way for any failure and/or inadequate performance of the Goodswhich arises from or is connected to the use in the Goods of non-genuine spare parts. We stronglyrecommend that only spare parts supplied or approved by us are used in the Goods.

We

You

Supplier

Goods

Warranty Period

······

5. No other person, firm or corporation is authorised by us to offer or give on our behalf any other orgreater warranty than that given under this warranty. The benefits conferred by this warranty are infavour of You and any person deriving title to the Goods through or under such person and areintended to be separate from and additional to all other rights and remedies that they may have inlaw in respect of the Goods.

6.

(a) either:(i) contact us within the Warranty Period on: 1300 650 644;or(ii) log a claim on our website www.seeleyinternational.com within the Warranty Period;

and(b) return the Goods to your nearest service centre (or to us at the address below) by prepaid

freight within the Warranty Period, together with (i) the legible and unmodified proof ofpurchase, which clearly indicates the name and address of the original retailer, the date andplace of purchase, the product name or other product serial number, and (ii) a copy of thecompleted Warranty Information below. (If you choose to return the Goods to us, there is anadditional requirement - they will also need to be accompanied by a covering letter whichstates your name and address and daytime telephone number, and the model and serialnumber of the goods.)

8. This warranty does not cover the cost of claiming under the warranty, it is your responsibility tocover all forwarding and return freight costs incurred in sending the Goods to and from yournearest service centre or us.

9. This warranty is only valid and enforceable in Australia.

Our liability under this warranty is limited to the extent permitted by law. That is, to the extent that it isfair and reasonable, if the Goods are not of a kind ordinarily acquired for personal, domestic orhousehold use or consumption, your remedies associated with any failure or defect of the Product willbe limited to:

(a) the replacement of the Goods or the supply of equivalent goods;(b) the repair of the Goods;(c) the payment of the cost of replacing the Goods or of acquiring equivalent goods;(d) the payment of the cost of having the Goods repairedand subject to the terms

and conditions included in this warranty.

To ensure that service either pursuant to the above warranty or otherwise is readily available, we haveestablished in all States authorised service centres, which are available to deal with servicerequirements.

For further information about your nearest service centre and other enquiries please call our ServiceCentre on:

If it is less than fifteen (15) days from the date of purchase of the Goods, in order to claim under thewarranty granted under clause 1 You must return the Goods to the Supplier at the place ofpurchase together with the proof of purchase.

7. If it is more than fifteen (15) days after the date of purchase, in order to claim under the warrantygranted under clause 1 You must:

1300 650 644Please retain your receipt as proof of purchase. Every request for warranty must beaccompanied by proof of purchase.

:

Complete the following for your records:

: ......................................................................................................................................

Serial Number:

Date purchased

Product

Purchased from

Convair CLIMATE MASTER

: ....../....../......

Model: CM12W CM12WX CP12HS

CM15WX CM15HW CP15W CP15HS

1 1 1

1 1 1 1

Service DepartmentSeeley International Pty Ltd112 O'Sullivan Beach Road, Lonsdale, South Australia 5160Customer service centre in Australia: 1300 650 644Website: www.seeleyinternational.com

SEELEY INTERNATIONAL – OWNER’S MANUAL 13ClimateMaster series Portable Refrigerated Air Conditioner12

®

Page 16: Convair CP15HS Manual

00238501-D convair.net.au AU 1112

Warranty Service

Australia 1-300-650-644seeleyinternational.com

It is the policy of Seeley International to introduce continualproduct improvement. Accordingly, specifications are

subject to change without notice. Please consult with yourdealer to confirm the specifications of the model selected.

®