CONTROL SYSTEM ELECTROPUMP USING …€œLP ” supply voltage ... VSD Restore factory settings...
Transcript of CONTROL SYSTEM ELECTROPUMP USING …€œLP ” supply voltage ... VSD Restore factory settings...
Page : 1/13Tinamics.com Energy Saving Application for WATER PUMP
TiNAMiCS Co., Ltd25/285
RamKhamHaeng 124Sapansoong, Sapansoong,
Bangkok 10240
Tel. : (+66) 0 2728-2902(+66) 0 2373-2734
Fax : (+66) 0 2728-1779
DISPLAY
FEATURES
SPECIAL FUNCTION
RANGE
VSD
TiNAMiCS Co., Ltd25/285
RamKhamHaeng 124Sapansoong, Sapansoong,
Bangkok 10240
Tel. : (+66) 0 2728-2902(+66) 0 2373-2734
Fax : (+66) 0 2728-1779Mobile : 0 9160-9211
ENERGY SAVING
V
S
D
VARIABLE
SPEED
DRIVER
VSD1 VSD1 -- BASICBASIC1~230 V1~230 V VSD1VSD1
1~230 V1~230 VVSD3VSD33~400V3~400V
CONTROL SYSTEM ELECTROPUMP USING INVERTER, PRESSURE AND FLOW SENSOR
Page : 2/13Tinamics.com Energy Saving Application for WATER PUMP
TiNAMiCS Co., Ltd25/285
RamKhamHaeng 124Sapansoong, Sapansoong,
Bangkok 10240
Tel. : (+66) 0 2728-2902(+66) 0 2373-2734
Fax : (+66) 0 2728-1779
DISPLAY
FEATURES
SPECIAL FUNCTION
RANGE
VSD
VSD1 VSD1 –– BASICBASICZB902170ZB902170
1” ½female
1” ¼male
IP55
•• Power Power supplysupply voltagevoltage
•• ElectropumpElectropump voltagevoltage
•• LiquidLiquid temperaturetemperature
•• Max Max operatingoperating pressurepressure
•• PressurePressure regulationregulation rangerange
ProtectionsProtections
4.5 Amp4.5 Amp•• Max.Max. motor motor currentcurrent
1x230V1x230V
3x230V3x230V
45 45 °°CC
10 Bar10 Bar
1 1 ÷÷ 9 Bar9 Bar
-- Dry Dry runningrunning –– OvercurrentOvercurrent-- OvertemperatureOvertemperature of the of the electronicselectronics
•• Set pointSet point 11
Working positionWorking position
Page : 3/13Tinamics.com Energy Saving Application for WATER PUMP
TiNAMiCS Co., Ltd25/285
RamKhamHaeng 124Sapansoong, Sapansoong,
Bangkok 10240
Tel. : (+66) 0 2728-2902(+66) 0 2373-2734
Fax : (+66) 0 2728-1779
DISPLAY
FEATURES
SPECIAL FUNCTION
RANGE
VSD
VSD1 VSD1 ZB902180ZB902180
1” ½female
1” ¼male
IP55
• OutputOutput relerele (free contact) (free contact)
ProtectionsProtections -- Dry Dry runningrunning –– AmperometricAmperometric –– OvercurrentOvercurrent-- OvertemperatureOvertemperature of the of the electronicselectronics
•• Power Power supplysupply voltagevoltage
•• ElectropumpElectropump voltagevoltage
•• LiquidLiquid temperaturetemperature
•• Max Max operatingoperating pressurepressure
•• PressurePressure regulationregulation rangerange
9.3 Amp9.3 Amp•• Max.Max. motor motor currentcurrent
1x230V1x230V
3x230V3x230V
45 45 °°CC
10 Bar10 Bar
1 1 ÷÷ 9 Bar9 Bar
•• Set pointSet point 22
• Digital input (Digital input (optocoupledoptocoupled)) FloatFloat switchswitchsecond set pointsecond set pointEnableEnable
• ConnectivityConnectivity
Working positionWorking position
Page : 4/13Tinamics.com Energy Saving Application for WATER PUMP
TiNAMiCS Co., Ltd25/285
RamKhamHaeng 124Sapansoong, Sapansoong,
Bangkok 10240
Tel. : (+66) 0 2728-2902(+66) 0 2373-2734
Fax : (+66) 0 2728-1779
DISPLAY
FEATURES
SPECIAL FUNCTION
RANGE
VSD
VSD3 VSD3 ZB902190ZB902190
1” ½female
1” ¼male
IP55
• OutputOutput relerele (free contact) (free contact)
ProtectionsProtections -- Dry Dry runningrunning –– AmperometricAmperometric –– OvercurrentOvercurrent-- OvertemperatureOvertemperature of the of the electronicselectronics
•• Power Power supplysupply voltagevoltage
•• ElectropumpElectropump voltagevoltage
•• LiquidLiquid temperaturetemperature
•• Max Max operatingoperating pressurepressure
•• PressurePressure regulationregulation rangerange
13.3 Amp13.3 Amp•• Max.Max. motor motor currentcurrent
3x400V3x400V
3x400V3x400V
45 45 °°CC
10 Bar10 Bar
1 1 ÷÷ 9 Bar9 Bar
•• Set pointSet point 22
• Digital input (Digital input (optocoupledoptocoupled))
• ConnectivityConnectivity
Working positionWorking position
Page : 5/13Tinamics.com Energy Saving Application for WATER PUMP
TiNAMiCS Co., Ltd25/285
RamKhamHaeng 124Sapansoong, Sapansoong,
Bangkok 10240
Tel. : (+66) 0 2728-2902(+66) 0 2373-2734
Fax : (+66) 0 2728-1779
DISPLAY
FEATURES
SPECIAL FUNCTION
RANGE
VSD
VSD VSD FEATURESFEATURES
Pressure transducer0-10 Bar calibrated
Flow transducer non calibrated
Max flow up to 300 l/minwith head loss < 8 m
PN10
BULT IN EMI FILTER (CLASS B: DOMESTIC)
Page : 6/13Tinamics.com Energy Saving Application for WATER PUMP
TiNAMiCS Co., Ltd25/285
RamKhamHaeng 124Sapansoong, Sapansoong,
Bangkok 10240
Tel. : (+66) 0 2728-2902(+66) 0 2373-2734
Fax : (+66) 0 2728-1779
DISPLAY
FEATURES
SPECIAL FUNCTION
RANGE
VSD
VSD VSD DISPLAYDISPLAY
Technical data Display
High and low valueButton programme
4 different programme level
DISPLAYDISPLAY““SbSb”” when pump is stoppedwhen pump is stopped““GOGO”” when pump is runningwhen pump is running
Page : 7/13Tinamics.com Energy Saving Application for WATER PUMP
TiNAMiCS Co., Ltd25/285
RamKhamHaeng 124Sapansoong, Sapansoong,
Bangkok 10240
Tel. : (+66) 0 2728-2902(+66) 0 2373-2734
Fax : (+66) 0 2728-1779
DISPLAY
FEATURES
SPECIAL FUNCTION
RANGE
VSDDISPLAY PARAMETERS DISPLAY PARAMETERS
“Fr” Display of instantaneous rotation frequency (in Hz)“UP” Display of instantaneous pressure (in bar) “C1” Display of instantaneous phase current (in A rms) “UE” Display code of the software version
““ MODEMODE””
DISPLAY VIEW(using “MODE” key from “Sb” or “Go”)
VSD VSD DISPLAYDISPLAY
Page : 8/13Tinamics.com Energy Saving Application for WATER PUMP
TiNAMiCS Co., Ltd25/285
RamKhamHaeng 124Sapansoong, Sapansoong,
Bangkok 10240
Tel. : (+66) 0 2728-2902(+66) 0 2373-2734
Fax : (+66) 0 2728-1779
DISPLAY
FEATURES
SPECIAL FUNCTION
RANGE
VSD
Use “+” and “-” key to modify the pressure Press “set” to exit
““ MODE & SETMODE & SET””
PRESSURE SET POINT SET UPPress “MODE” & “SET” until “Sp”
(set point) appears
DISPLAY PARAMETERS DISPLAY PARAMETERS
VSD VSD DISPLAYDISPLAY
Page : 9/13Tinamics.com Energy Saving Application for WATER PUMP
TiNAMiCS Co., Ltd25/285
RamKhamHaeng 124Sapansoong, Sapansoong,
Bangkok 10240
Tel. : (+66) 0 2728-2902(+66) 0 2373-2734
Fax : (+66) 0 2728-1779
DISPLAY
FEATURES
SPECIAL FUNCTION
RANGE
VSD
““ MODE & SET & MODE & SET & ---- ””
INSTALLER MENU(pushbuttons “MODE” & “SET” & “-” pressed for 5’)
“rC” Setting of the electro pump nominal phase current“Rt” Setting of the rotation direction “Od” Setting of the operation mode of VSD“rP” Setting of pressure decrement to restart“Ad” Setting of the address (necessary on boosters with more
than one pump in change over)“- -“ communication disabled.“1“ slave“2“ master.
”Eb” enable/disable booster (duty assistance /duty stand-by)
Press “set” to exit or after 2 minute
DISPLAY PARAMETERS DISPLAY PARAMETERS
VSD VSD DISPLAYDISPLAY
Page : 10/13Tinamics.com Energy Saving Application for WATER PUMP
TiNAMiCS Co., Ltd25/285
RamKhamHaeng 124Sapansoong, Sapansoong,
Bangkok 10240
Tel. : (+66) 0 2728-2902(+66) 0 2373-2734
Fax : (+66) 0 2728-1779
DISPLAY
FEATURES
SPECIAL FUNCTION
RANGE
VSD
VSD VSD DISPLAYDISPLAY
““ MODE & SET & + MODE & SET & + ””INSTALLER MENU
(pushbuttons “MODE” & “SET” & “-” pressed for 5’)
“tb” Setting time out to enter block due to lack of water“GP” Setting of the integral coefficient gain PI“GI” Setting of the proportional coefficient gain of PI“FS” Setting of the highest frequency of rotation of the electro pump“dP” Setting of pressure differential at low flows“Ft” Setting of low flow threshold“CM” “0” no change over “1” change every time in stand-by or 2 hours“AE” frost protection - Autotest“i1” Setting digital input 1 (float switch )“i2” Setting digital input 2 (second pressure set point selection)“i3” Setting digital input 3 (enable)“P1” Set point 1: active according to digital input number 2“O1” Setting output function 1 (value default:2; function : ON if alarm)“O2” Setting output function 2 (value default:2; function : ON when run)
Press “set” to exit or after 2 minute
DISPLAY PARAMETERS DISPLAY PARAMETERS
Page : 11/13Tinamics.com Energy Saving Application for WATER PUMP
TiNAMiCS Co., Ltd25/285
RamKhamHaeng 124Sapansoong, Sapansoong,
Bangkok 10240
Tel. : (+66) 0 2728-2902(+66) 0 2373-2734
Fax : (+66) 0 2728-1779
DISPLAY
FEATURES
SPECIAL FUNCTION
RANGE
VSD
FAULT CODE
“bL” dry running protection ***“LP” supply voltage too low ***“HP” supply voltage too high ***“LL” Low voltage line“Ot” over temperature of the electronics ***“oC” rms phase current higher than the nominal set ***“oF” over current protection of the electronics ***“EC” Block due to wrong nominal current setting
(default from factory = 0.1 A)“E1- E7” Internal error 1
“F1” Status / input alarm“F3” Status / input alarm 3
Press simultaneously Press simultaneously ““++”” & & ““--”” keys to reset fault conditionkeys to reset fault condition
*** AUTOMATIC RESTARTING*** AUTOMATIC RESTARTING
DISPLAY PARAMETERS DISPLAY PARAMETERS
VSD VSD DISPLAYDISPLAY
Page : 12/13Tinamics.com Energy Saving Application for WATER PUMP
TiNAMiCS Co., Ltd25/285
RamKhamHaeng 124Sapansoong, Sapansoong,
Bangkok 10240
Tel. : (+66) 0 2728-2902(+66) 0 2373-2734
Fax : (+66) 0 2728-1779
DISPLAY
FEATURES
SPECIAL FUNCTION
RANGE
VSD
Restore factory settingsSystem resetMONITOR (pushbuttons “SET” & “-” for 2 sec)
“UF” actual flow reading“ZF” flow reading with pump stopped“FM” Display of the maximum frequency (in Hz)“tE” Display of the power transistor temperature (in °C)“GS” Display GO status (“AG”:a.freeze “go” SP;P1)“FF” Display of the historical faults ( “+” & “-“ per scroll)
SPECIAL FUNCTION
SPECIAL FUNCTION
Page : 13/13Tinamics.com Energy Saving Application for WATER PUMP
TiNAMiCS Co., Ltd25/285
RamKhamHaeng 124Sapansoong, Sapansoong,
Bangkok 10240
Tel. : (+66) 0 2728-2902(+66) 0 2373-2734
Fax : (+66) 0 2728-1779
DISPLAY
FEATURES
SPECIAL FUNCTION
RANGE
VSD
RANGE
STAND ALONESTAND ALONE MAXMAX MULTINOXMULTINOX
MULTINOXMULTINOX--VEVE VLRVLRDHR9DHR9