2233 Rue de l’Aviation, Dorval, QC H9P 2X6 514.739.9984, 1.866.280.2332 1.866.265.8801 • www.stanprols.com DESCRIPTION The Orbit RLR series is our LED recessed multi-spot. Whether you’re designing a completely new commercial venue or planning a renovation, the Orbit RLR offers the flexibility for either of those options with the same housing. This is the ideal fixture for commercial office, residential, retail, restaurant and hotel lighting projects that require the beauty of recessed lighting. SPECIFICATIONS Non-IC new construction or existant ceiling Material: Diecast aluminum Optical compartment and metal backbox Installation: Integral wire connection box Integral transformer for T-bar & drywall ceiling available Adjustable: Universal joint for independent adjustment of each gimbal head, horizontal 356°, vertical 56° LAMP/DRIVER Per lamp* S1 LED 23W 2200lm at 3000K, 80+ CRI or 1800lm at 3000K, 90+ CRI S2 LED 33W 3000lm at 3000K, 80+ CRI or 2400lm at 3000K, 90+ CRI S3 LED 45W 4300lm at 3000K, 80+ CRI or 3600lm at 3000K, 90+ CRI S4 LED 52W 5000lm at 3000K, 80+ CRI or 4100lm at 3000K, 90+ CRI Driver Integral electronic, dimmable with 0-10VDC dimmers Estimated lifespan of over 50,000 hours to L70 * Lumens are based on 36° flood beam angle. DIMMER LIST Lutron Diva ® DVTV Diva ® DVSCTV Diva ® DVSTV Diva ® DVSCSTV Nova ® NFTV Leviton IllumaTech IP7 series Philips Sunrise-SRI200ZTUNV The fixture dimmer compatibility table shown above is for dimming functionality only. The dimmers listed in this chart may not comply to ICES 005 class A or B standards. To confirm ICES 005 compliance please contact the dimmer manufacturer. REFLECTOR POSITIONING GUIDE One individual reflector per gimbal. Please specify in the ordering guide. ** The first reflector is always positioned next to the junction box. 1** 3 2 1** 3 2 4 1** 1** 2 ORBIT – RLR AdjUSTAble mUlTIPle led lUmINAIRe 005 ICES Approvals: CSA Certified to C22.2 #250, UL1598 ICES 005 yr warranty Project: Contractor:

Transcript of Contrator ORBIT – RLR · The Orbit RLR series is our LED recessed multi-spot. ... Item number Nbr...

2233 Rue de l’Aviation, Dorval, QC H9P 2X6 514.739.9984, 1.866.280.2332 • 1.866.265.8801 • www.stanprols.com

DESCRIPTION

The Orbit RLR series is our LED recessed multi-spot. Whether you’re designing a completely new commercial venue or planning a renovation, the Orbit RLR offers the flexibility for either of those options with the same housing. This is the ideal fixture for commercial office, residential, retail, restaurant and hotel lighting projects that require the beauty of recessed lighting.

SPECIFICATIONS

Non-IC new construction or existant ceiling

Material: Diecast aluminum Optical compartment and metal backboxInstallation: Integral wire connection box Integral transformer for T-bar & drywall ceiling availableAdjustable: Universal joint for independent adjustment of each gimbal

head, horizontal 356°, vertical 56°

LAMP/DRIVER

Per lamp* S1 LED 23W 2200lm at 3000K, 80+ CRI or 1800lm at 3000K, 90+ CRI

S2 LED 33W 3000lm at 3000K, 80+ CRI or 2400lm at 3000K, 90+ CRI

S3 LED 45W 4300lm at 3000K, 80+ CRI or 3600lm at 3000K, 90+ CRI

S4 LED 52W 5000lm at 3000K, 80+ CRI or 4100lm at 3000K, 90+ CRI

Driver Integral electronic, dimmable with 0-10VDC dimmers Estimated lifespan of over 50,000 hours to L70

* Lumens are based on 36° flood beam angle.DIMMER LISTLutron Diva® DVTV

Diva® DVSCTVDiva® DVSTVDiva® DVSCSTVNova® NFTV

Leviton IllumaTech IP7 seriesPhilips Sunrise-SRI200ZTUNV

The fixture dimmer compatibility table shown above is for dimming functionality only. The dimmers listed in this chart may not comply to ICES 005 class A or B standards. To confirm ICES 005 compliance please contact the dimmer manufacturer.

REFLECTOR POSITIONINg guIDE

One individual reflector per gimbal. Please specify in the ordering guide.

** The first reflector is always positioned next to the junction box.

1** 32

1** 32 4

1** 1** 2

ORBIT – RLRAdjUSTAble mUlTIPle led lUmINAIRe

005ICES

Approvals: CSA Certified to C22.2 #250, UL1598ICES 005

yr

warranty

Project:

Contractor:

2233 Rue de l’Aviation, Dorval, QC H9P 2X6 514.739.9984, 1.866.280.2332 • 1.866.265.8801 • www.stanprols.com

RLR L

Serieslamp configuration

lamp type

lumen package delivered(per lamp)***

CRI Voltage****Housingcolour

Trim colour

Gimbal colour

Colour temperature

Reflectors (one per gimbal)Option

1 2 3 4

RLR 1 - 1 lamp2 - 2 lamps3 - 3 lamps4 - 4 lamps

L - led S1 - 2200 lm (23W)

S2 - 3000 lm (33W)

S3 - 4300 lm (45W)

S4 - 5000 lm (52W)

80 - 80+ CRI90 - 90+ CRI

A - 120VH - 347V

B - blackW***** - White

B - blackS - SilverW - White

B - blackS - SilverW - White

27K - 2700K30K - 3000K35K****** - 3500K40K - 4000K

S - SpotM - med.F - Flood

S - SpotM - med.F - Flood

S - SpotM - med.F - Flood

S - SpotM - med.F - Flood

DIM1 - 0-10V dC dimming driver

*** Please see lumen table for detailed CRI. Approximate delivered lumens. **** For other voltages, please consult factory. ***** Use with white gimbal only. ****** 3500K, 80+ CRI.

ORDERINg guIDE

OPTIONAL PLASTER FRAME Order separately

Item number Nbr of lamps dim. A dim. b dim. C dim. dPF-Rg/RF-1 1 lamp 7.28" 7.4" 8.27" 10.30"PF-Rg/RF-2 2 lamps 7.28" 14.76" 15.75" 10.30"PF-Rg/RF-3 3 lamps 7.28" 21.26" 22.25" 10.30"PF-Rg/RF-4 4 lamps 7.28" 27.76" 28.74" 10.30"

LuMEN CRI TABLE80 90

S1 2200 lm 1800 lmS2 3000 lm 2400 lmS3 4300 lm 3600 lmS4 5000 lm 4100 lm

Note: Lumen information is based on 36° flood beam reflector and 3000K colour temperature. Please refer to IES files for more information.

Dimension C

Dim

ensi

on D

Dimension C

Dim

ensi

on D

Ceiling opening(dimensions A & b)

1.18"

Dimension B

Dim

ensi

on A

0.5"

DIMENSIONS

ORBIT – RLRAdjUSTAble mUlTIPle led lUmINAIRe

005ICES

Approvals: CSA Certified to C22.2 #250, UL1598ICES 005

yr

warranty

Project:

Contractor:

2233 Rue de l’Aviation, Dorval, QC H9P 2X6 514.739.9984, 1.866.280.2332 • 1.866.265.8801 • www.stanprols.com

PHOTOMETRY – 4895.1 LM / 80 CRI

PHOTOMETRY – 5303.9 LM / 80 CRI

PHOTOMETRY – 5026.7 LM / 80 CRI

PHOTOMETRY – 4183.8 LM / 90 CRI

RLR-1LS480-A/30K/FInput wattage: 52Total luminaire lumens: 4895.1lumens per watt: 94.14beam angle: Flood 36°

RLR-1LS480-A/30K/SInput wattage: 52Total luminaire lumens: 5303.9lumens per watt: 102beam angle: Spot 23°

RLR-1LS480-A/30K/MInput wattage: 52Total luminaire lumens: 5026.7lumens per watt: 96.67beam angle: Medium 27°

RLR-1LS490-A/30K/FInput wattage: 52Total luminaire lumens: 4183.8lumens per watt: 80.65beam angle: Flood 35.7°

Filename: RLR-1-LS4-80-30K-FManufacturer: Stanpro

Luminaire: RLR-L

Luminaire Cat: RLR-1-L-S4-80-(A-H)-(B-W)-(B-S-W)-(B-S-W)-30K-F

Lamp: (1) COB VERO18-(BXRC-30G4000-C-73-SE) c/w Universal Driver D15CC55UNVTW-LS @ 120.00V

Distribution: Direct Type - Downlight

Lamp Output: Total luminaire Lumens: 4895.1

Max Candela: 10,764.0 at Horizontal: 0°, Vertical: 0°

Input Wattage: 52

Luminous Opening: Circular (Dia: 2.75")

Test: S1702172-R1 config from

Test Lab: Spectra Lux Industries Inc.

Photometry : Type C

CIE Class: Direct

Cutoff Class: Full Cutoff

Nema Type: 5 X 5

Zonal Lumen SummaryZone Lumens % Luminaire

0-30 4,058.5 82.9%

0-40 4,815.7 98.4%

0-60 4,895.1 100%

60-90 0 0%

70-100 0 0%

90-120 0 0%

0-90 4,895.1 100%

90-180 0 0%

0-180 4,895.1 100%

Lumens Per ZoneZone Lumens % Total Zone Lumens % Total

0-10 941.2 19.2% 90-100 0 0%

10-20 1,830.9 37.4% 100-110 0 0%

20-30 1,286.5 26.3% 110-120 0 0%

30-40 757.1 15.5% 120-130 0 0%

40-50 79.4 1.6% 130-140 0 0%

50-60 0 0.0% 140-150 0 0%

60-70 0 0.0% 150-160 0 0%

70-80 0 0.0% 160-170 0 0%

80-90 0 0.0% 170-180 0 0%

Coefficients Of Utilization - Zonal Cavity MethodEffective Floor Cavity Reflectance: 20%

RCC %: 80 70 50 30 10 0

RW %:

RCR: 0

1

70 50 30 0

1.19 1.19 1.19 1.19

1.14 1.12 1.10 1.08

70 50 30 0

1.16 1.16 1.16 1.00

1.12 1.10 1.08 .95

50 30 20

1.11 1.11 1.11

1.06 1.04 1.03

50 30 20

1.06 1.06 1.06

1.02 1.01 1.00

50 30 20

1.02 1.02 1.02

.99 .98 .97

0

1.00

.95

Page 1 of 2Photometric Report: RLR-1-LS4-80-30K-F

1/19/2018file:///C:/ProgramData/PhotometricsPro/temp/RLR-1-LS4-80-30K-F_rep.htm

Filename: RLR-1-LS4-80-30K-MManufacturer: Stanpro

Luminaire: RLR-L

Luminaire Cat: RLR-1-L-S4-80-(A-H)-(B-W)-(B-S-W)-(B-S-W)-30K-M

Lamp: (1) COB VERO18-(BXRC-30G4000-C-73-SE) c/w Universal Driver D15CC55UNVTW-LS @ 120.00V

Distribution: Direct Type - Downlight

Lamp Output: Total luminaire Lumens: 5026.7

Max Candela: 15,846.5 at Horizontal: 0°, Vertical: 1°

Input Wattage: 52

Luminous Opening: Circular (Dia: 2.75")

Test: S1702171-R1 config from

Test Lab: Spectra Lux Industries Inc.

Photometry : Type C

CIE Class: Direct

Cutoff Class: Full Cutoff

Nema Type: 4 X 4

Zonal Lumen SummaryZone Lumens % Luminaire

0-30 4,224.3 84%

0-40 4,950.6 98.5%

0-60 5,026.7 100%

60-90 0 0%

70-100 0 0%

90-120 0 0%

0-90 5,026.7 100%

90-180 0 0%

0-180 5,026.7 100%

Lumens Per ZoneZone Lumens % Total Zone Lumens % Total

0-10 1,305.2 26.0% 90-100 0 0%

10-20 1,840.7 36.6% 100-110 0 0%

20-30 1,078.3 21.5% 110-120 0 0%

30-40 726.3 14.4% 120-130 0 0%

40-50 76.2 1.5% 130-140 0 0%

50-60 0 0.0% 140-150 0 0%

60-70 0 0.0% 150-160 0 0%

70-80 0 0.0% 160-170 0 0%

80-90 0 0.0% 170-180 0 0%

Coefficients Of Utilization - Zonal Cavity MethodEffective Floor Cavity Reflectance: 20%

RCC %: 80 70 50 30 10 0

RW %:

RCR: 0

1

70 50 30 0

1.19 1.19 1.19 1.19

1.14 1.12 1.10 1.08

70 50 30 0

1.16 1.16 1.16 1.00

1.12 1.10 1.08 .96

50 30 20

1.11 1.11 1.11

1.06 1.05 1.03

50 30 20

1.06 1.06 1.06

1.02 1.01 1.00

50 30 20

1.02 1.02 1.02

.99 .98 .97

0

1.00

.96

Page 1 of 2Photometric Report: RLR-1-LS4-80-30K-M

1/19/2018file:///C:/ProgramData/PhotometricsPro/temp/RLR-1-LS4-80-30K-M_rep.htm

Filename: RLR-1-LS4-80-30K-FManufacturer: Stanpro

Luminaire: RLR-L

Luminaire Cat: RLR-1-L-S4-80-(A-H)-(B-W)-(B-S-W)-(B-S-W)-30K-F

Lamp: (1) COB VERO18-(BXRC-30G4000-C-73-SE) c/w Universal Driver D15CC55UNVTW-LS @ 120.00V

Distribution: Direct Type - Downlight

Lamp Output: Total luminaire Lumens: 4895.1

Max Candela: 10,764.0 at Horizontal: 0°, Vertical: 0°

Input Wattage: 52

Luminous Opening: Circular (Dia: 2.75")

Test: S1702172-R1 config from

Test Lab: Spectra Lux Industries Inc.

Photometry : Type C

CIE Class: Direct

Cutoff Class: Full Cutoff

Nema Type: 5 X 5

Zonal Lumen SummaryZone Lumens % Luminaire

0-30 4,058.5 82.9%

0-40 4,815.7 98.4%

0-60 4,895.1 100%

60-90 0 0%

70-100 0 0%

90-120 0 0%

0-90 4,895.1 100%

90-180 0 0%

0-180 4,895.1 100%

Lumens Per ZoneZone Lumens % Total Zone Lumens % Total

0-10 941.2 19.2% 90-100 0 0%

10-20 1,830.9 37.4% 100-110 0 0%

20-30 1,286.5 26.3% 110-120 0 0%

30-40 757.1 15.5% 120-130 0 0%

40-50 79.4 1.6% 130-140 0 0%

50-60 0 0.0% 140-150 0 0%

60-70 0 0.0% 150-160 0 0%

70-80 0 0.0% 160-170 0 0%

80-90 0 0.0% 170-180 0 0%

Coefficients Of Utilization - Zonal Cavity MethodEffective Floor Cavity Reflectance: 20%

RCC %: 80 70 50 30 10 0

RW %:

RCR: 0

1

70 50 30 0

1.19 1.19 1.19 1.19

1.14 1.12 1.10 1.08

70 50 30 0

1.16 1.16 1.16 1.00

1.12 1.10 1.08 .95

50 30 20

1.11 1.11 1.11

1.06 1.04 1.03

50 30 20

1.06 1.06 1.06

1.02 1.01 1.00

50 30 20

1.02 1.02 1.02

.99 .98 .97

0

1.00

.95

Page 1 of 2Photometric Report: RLR-1-LS4-80-30K-F

1/19/2018file:///C:/ProgramData/PhotometricsPro/temp/RLR-1-LS4-80-30K-F_rep.htm

Filename: RLR-1-LS4-80-30K-MManufacturer: Stanpro

Luminaire: RLR-L

Luminaire Cat: RLR-1-L-S4-80-(A-H)-(B-W)-(B-S-W)-(B-S-W)-30K-M

Lamp: (1) COB VERO18-(BXRC-30G4000-C-73-SE) c/w Universal Driver D15CC55UNVTW-LS @ 120.00V

Distribution: Direct Type - Downlight

Lamp Output: Total luminaire Lumens: 5026.7

Max Candela: 15,846.5 at Horizontal: 0°, Vertical: 1°

Input Wattage: 52

Luminous Opening: Circular (Dia: 2.75")

Test: S1702171-R1 config from

Test Lab: Spectra Lux Industries Inc.

Photometry : Type C

CIE Class: Direct

Cutoff Class: Full Cutoff

Nema Type: 4 X 4

Zonal Lumen SummaryZone Lumens % Luminaire

0-30 4,224.3 84%

0-40 4,950.6 98.5%

0-60 5,026.7 100%

60-90 0 0%

70-100 0 0%

90-120 0 0%

0-90 5,026.7 100%

90-180 0 0%

0-180 5,026.7 100%

Lumens Per ZoneZone Lumens % Total Zone Lumens % Total

0-10 1,305.2 26.0% 90-100 0 0%

10-20 1,840.7 36.6% 100-110 0 0%

20-30 1,078.3 21.5% 110-120 0 0%

30-40 726.3 14.4% 120-130 0 0%

40-50 76.2 1.5% 130-140 0 0%

50-60 0 0.0% 140-150 0 0%

60-70 0 0.0% 150-160 0 0%

70-80 0 0.0% 160-170 0 0%

80-90 0 0.0% 170-180 0 0%

Coefficients Of Utilization - Zonal Cavity MethodEffective Floor Cavity Reflectance: 20%

RCC %: 80 70 50 30 10 0

RW %:

RCR: 0

1

70 50 30 0

1.19 1.19 1.19 1.19

1.14 1.12 1.10 1.08

70 50 30 0

1.16 1.16 1.16 1.00

1.12 1.10 1.08 .96

50 30 20

1.11 1.11 1.11

1.06 1.05 1.03

50 30 20

1.06 1.06 1.06

1.02 1.01 1.00

50 30 20

1.02 1.02 1.02

.99 .98 .97

0

1.00

.96

Page 1 of 2Photometric Report: RLR-1-LS4-80-30K-M

1/19/2018file:///C:/ProgramData/PhotometricsPro/temp/RLR-1-LS4-80-30K-M_rep.htm

Zonal lumen summaryZone lumens % Fixture

0-30 4058.5 82.9%0-40 4815.7 98.4%0-60 4895.1 100%60-90 0 0%70-100 0 0%90-120 0 0%0-90 4895.1 100%90-180 0 0%0-180 4895.1 100%

Zonal lumen summaryZone lumens % Fixture

0-30 4366.8 82.3%0-40 5188.1 97.8%0-60 5303.9 100%60-90 0 0%70-100 0 0%90-120 0 0%0-90 5303.9 100%90-180 0 0%0-180 5303.9 100%

Zonal lumen summaryZone lumens % Fixture

0-30 4224.3 84%0-40 4950.6 98.5%0-60 5026.7 100%60-90 0 0%70-100 0 0%90-120 0 0%0-90 5026.7 100%90-180 0 0%0-180 5026.7 100%

Zonal lumen summaryZone lumens % Fixture

0-30 3468.8 82.9%0-40 4115.9 98.4%0-60 4183.8 100%60-90 0 0%70-100 0 0%90-120 0 0%0-90 4183.8 100%90-180 0 0%0-180 4183.8 100%

ORBIT – RLRAdjUSTAble mUlTIPle led lUmINAIRe

Filename: RLR-1-LS4-80-30K-SManufacturer: Stanpro

Luminaire: RLR-L

Luminaire Cat: RLR-1-L-S4-80-(A-H)-(B-W)-(B-S-W)-(B-S-W)-30K-S

Lamp: (1) COB VERO18-(BXRC-30G4000-C-73-SE) c/w Universal Driver D15CC55UNVTW-LS @ 120.00V

Distribution: Direct Type - Downlight

Lamp Output: Total luminaire Lumens: 5303.9

Max Candela: 20,955.9 at Horizontal: 0°, Vertical: 1°

Input Wattage: 52

Luminous Opening: Circular (Dia: 2.75")

Test: S1702205-R1 config from

Test Lab: Spectra Lux Industries Inc.

Photometry : Type C

CIE Class: Direct

Cutoff Class: Full Cutoff

Nema Type: 4 X 4

Zonal Lumen SummaryZone Lumens % Luminaire

0-30 4,366.8 82.3%

0-40 5,188.1 97.8%

0-60 5,303.9 100%

60-90 0 0%

70-100 0 0%

90-120 0 0%

0-90 5,303.9 100%

90-180 0 0%

0-180 5,303.9 100%

Lumens Per ZoneZone Lumens % Total Zone Lumens % Total

0-10 1,682.5 31.7% 90-100 0 0%

10-20 1,692.2 31.9% 100-110 0 0%

20-30 992.2 18.7% 110-120 0 0%

30-40 821.3 15.5% 120-130 0 0%

40-50 115.8 2.2% 130-140 0 0%

50-60 0 0.0% 140-150 0 0%

60-70 0 0.0% 150-160 0 0%

70-80 0 0.0% 160-170 0 0%

80-90 0 0.0% 170-180 0 0%

Coefficients Of Utilization - Zonal Cavity MethodEffective Floor Cavity Reflectance: 20%

RCC %: 80 70 50 30 10 0

RW %:

RCR: 0

1

70 50 30 0

1.19 1.19 1.19 1.19

1.15 1.12 1.10 1.08

70 50 30 0

1.16 1.16 1.16 1.00

1.12 1.10 1.08 .96

50 30 20

1.11 1.11 1.11

1.06 1.05 1.03

50 30 20

1.06 1.06 1.06

1.02 1.01 1.00

50 30 20

1.02 1.02 1.02

.99 .98 .97

0

1.00

.96

Page 1 of 2Photometric Report: RLR-1-LS4-80-30K-S

1/19/2018file:///C:/ProgramData/PhotometricsPro/temp/RLR-1-LS4-80-30K-S_rep.htm

Filename: RLR-1-LS4-80-30K-SManufacturer: Stanpro

Luminaire: RLR-L

Luminaire Cat: RLR-1-L-S4-80-(A-H)-(B-W)-(B-S-W)-(B-S-W)-30K-S

Lamp: (1) COB VERO18-(BXRC-30G4000-C-73-SE) c/w Universal Driver D15CC55UNVTW-LS @ 120.00V

Distribution: Direct Type - Downlight

Lamp Output: Total luminaire Lumens: 5303.9

Max Candela: 20,955.9 at Horizontal: 0°, Vertical: 1°

Input Wattage: 52

Luminous Opening: Circular (Dia: 2.75")

Test: S1702205-R1 config from

Test Lab: Spectra Lux Industries Inc.

Photometry : Type C

CIE Class: Direct

Cutoff Class: Full Cutoff

Nema Type: 4 X 4

Zonal Lumen SummaryZone Lumens % Luminaire

0-30 4,366.8 82.3%

0-40 5,188.1 97.8%

0-60 5,303.9 100%

60-90 0 0%

70-100 0 0%

90-120 0 0%

0-90 5,303.9 100%

90-180 0 0%

0-180 5,303.9 100%

Lumens Per ZoneZone Lumens % Total Zone Lumens % Total

0-10 1,682.5 31.7% 90-100 0 0%

10-20 1,692.2 31.9% 100-110 0 0%

20-30 992.2 18.7% 110-120 0 0%

30-40 821.3 15.5% 120-130 0 0%

40-50 115.8 2.2% 130-140 0 0%

50-60 0 0.0% 140-150 0 0%

60-70 0 0.0% 150-160 0 0%

70-80 0 0.0% 160-170 0 0%

80-90 0 0.0% 170-180 0 0%

Coefficients Of Utilization - Zonal Cavity MethodEffective Floor Cavity Reflectance: 20%

RCC %: 80 70 50 30 10 0

RW %:

RCR: 0

1

70 50 30 0

1.19 1.19 1.19 1.19

1.15 1.12 1.10 1.08

70 50 30 0

1.16 1.16 1.16 1.00

1.12 1.10 1.08 .96

50 30 20

1.11 1.11 1.11

1.06 1.05 1.03

50 30 20

1.06 1.06 1.06

1.02 1.01 1.00

50 30 20

1.02 1.02 1.02

.99 .98 .97

0

1.00

.96

Page 1 of 2Photometric Report: RLR-1-LS4-80-30K-S

1/19/2018file:///C:/ProgramData/PhotometricsPro/temp/RLR-1-LS4-80-30K-S_rep.htm

Filename: RLR-1-LS4-90-30K-FManufacturer: Stanpro

Luminaire: RLR-L

Luminaire Cat: RLR-1-L-S4-90-(A-H)-(B-W)-(B-S-W)-(B-S-W)-30K-F

Lamp: (1) COB VERO18-(BXRC-30G4000-C-73-SE) c/w Universal Driver D15CC55UNVTW-LS @ 120.00V

Distribution: Direct Type - Downlight

Lamp Output: Total luminaire Lumens: 4183.8

Max Candela: 9,200.0 at Horizontal: 0°, Vertical: 0°

Input Wattage: 52

Luminous Opening: Circular (Dia: 2.75")

Test: S1702172-R1

Test Lab: Spectra Lux Industries Inc.

Photometry : Type C

CIE Class: Direct

Cutoff Class: Full Cutoff

Nema Type: 5 X 5

Zonal Lumen SummaryZone Lumens % Luminaire

0-30 3,468.8 82.9%

0-40 4,115.9 98.4%

0-60 4,183.8 100%

60-90 0 0%

70-100 0 0%

90-120 0 0%

0-90 4,183.8 100%

90-180 0 0%

0-180 4,183.8 100%

Lumens Per ZoneZone Lumens % Total Zone Lumens % Total

0-10 804.4 19.2% 90-100 0 0%

10-20 1,564.9 37.4% 100-110 0 0%

20-30 1,099.5 26.3% 110-120 0 0%

30-40 647.1 15.5% 120-130 0 0%

40-50 67.9 1.6% 130-140 0 0%

50-60 0 0.0% 140-150 0 0%

60-70 0 0.0% 150-160 0 0%

70-80 0 0.0% 160-170 0 0%

80-90 0 0.0% 170-180 0 0%

Coefficients Of Utilization - Zonal Cavity MethodEffective Floor Cavity Reflectance: 20%

RCC %: 80 70 50 30 10 0

RW %:

RCR: 0

1

70 50 30 0

1.19 1.19 1.19 1.19

1.14 1.12 1.10 1.08

70 50 30 0

1.16 1.16 1.16 1.00

1.12 1.10 1.08 .95

50 30 20

1.11 1.11 1.11

1.06 1.04 1.03

50 30 20

1.06 1.06 1.06

1.02 1.01 1.00

50 30 20

1.02 1.02 1.02

.99 .98 .97

0

1.00

.95

Page 1 of 2Photometric Report: RLR-1-LS4-90-30K-F

1/19/2018file:///C:/ProgramData/PhotometricsPro/temp/RLR-1-LS4-90-30K-F_rep.htm

Filename: RLR-1-LS4-90-30K-FManufacturer: Stanpro

Luminaire: RLR-L

Luminaire Cat: RLR-1-L-S4-90-(A-H)-(B-W)-(B-S-W)-(B-S-W)-30K-F

Lamp: (1) COB VERO18-(BXRC-30G4000-C-73-SE) c/w Universal Driver D15CC55UNVTW-LS @ 120.00V

Distribution: Direct Type - Downlight

Lamp Output: Total luminaire Lumens: 4183.8

Max Candela: 9,200.0 at Horizontal: 0°, Vertical: 0°

Input Wattage: 52

Luminous Opening: Circular (Dia: 2.75")

Test: S1702172-R1

Test Lab: Spectra Lux Industries Inc.

Photometry : Type C

CIE Class: Direct

Cutoff Class: Full Cutoff

Nema Type: 5 X 5

Zonal Lumen SummaryZone Lumens % Luminaire

0-30 3,468.8 82.9%

0-40 4,115.9 98.4%

0-60 4,183.8 100%

60-90 0 0%

70-100 0 0%

90-120 0 0%

0-90 4,183.8 100%

90-180 0 0%

0-180 4,183.8 100%

Lumens Per ZoneZone Lumens % Total Zone Lumens % Total

0-10 804.4 19.2% 90-100 0 0%

10-20 1,564.9 37.4% 100-110 0 0%

20-30 1,099.5 26.3% 110-120 0 0%

30-40 647.1 15.5% 120-130 0 0%

40-50 67.9 1.6% 130-140 0 0%

50-60 0 0.0% 140-150 0 0%

60-70 0 0.0% 150-160 0 0%

70-80 0 0.0% 160-170 0 0%

80-90 0 0.0% 170-180 0 0%

Coefficients Of Utilization - Zonal Cavity MethodEffective Floor Cavity Reflectance: 20%

RCC %: 80 70 50 30 10 0

RW %:

RCR: 0

1

70 50 30 0

1.19 1.19 1.19 1.19

1.14 1.12 1.10 1.08

70 50 30 0

1.16 1.16 1.16 1.00

1.12 1.10 1.08 .95

50 30 20

1.11 1.11 1.11

1.06 1.04 1.03

50 30 20

1.06 1.06 1.06

1.02 1.01 1.00

50 30 20

1.02 1.02 1.02

.99 .98 .97

0

1.00

.95

Page 1 of 2Photometric Report: RLR-1-LS4-90-30K-F

1/19/2018file:///C:/ProgramData/PhotometricsPro/temp/RLR-1-LS4-90-30K-F_rep.htm

Project:

Contractor:

2233 Rue de l’Aviation, Dorval, QC H9P 2X6 514.739.9984, 1.866.280.2332 • 1.866.265.8801 • www.stanprols.com

PHOTOMETRY – 4296.4 LM / 90 CRI PHOTOMETRY – 4533.2 LM / 90 CRI

RLR-1LS490-A/30K/MInput wattage: 52Total luminaire lumens: 4296.4lumens per watt: 82.62beam angle: Medium 27°

RLR-1LS490-A/30K/SInput wattage: 52Total luminaire lumens: 4533.2lumens per watt: 87.18beam angle: Spot 23°

Zonal lumen summaryZone lumens % Fixture

0-30 3610.5 84%0-40 4231.3 98.5%0-60 4296.4 100%60-90 0 0%70-100 0 0%90-120 0 0%0-90 4296.4 100%90-180 0 0%0-180 4296.4 100%

Zonal lumen summaryZone lumens % Fixture

0-30 3732.3 82.3%0-40 4434.3 97.8%0-60 4533.2 100%60-90 0 0%70-100 0 0%90-120 0 0%0-90 4533.2 100%90-180 0 0%0-180 4533.2 100%

ORBIT – RLRAdjUSTAble mUlTIPle led lUmINAIRe

Filename: RLR-1-LS4-90-30K-MManufacturer: Stanpro

Luminaire: RLR-L

Luminaire Cat: RLR-1-L-S4-90-(A-H)-(B-W)-(B-S-W)-(B-S-W)-30K-M

Lamp: (1) COB VERO18-(BXRC-30G4000-C-73-SE) c/w Universal Driver D15CC55UNVTW-LS @ 120.00V

Distribution: Direct Type - Downlight

Lamp Output: Total luminaire Lumens: 4296.4

Max Candela: 13,544.0 at Horizontal: 0°, Vertical: 1°

Input Wattage: 52

Luminous Opening: Circular (Dia: 2.75")

Test: S1702171-R1

Test Lab: Spectra Lux Industries Inc.

Photometry : Type C

CIE Class: Direct

Cutoff Class: Full Cutoff

Nema Type: 4 X 4

Zonal Lumen SummaryZone Lumens % Luminaire

0-30 3,610.5 84%

0-40 4,231.3 98.5%

0-60 4,296.4 100%

60-90 0 0%

70-100 0 0%

90-120 0 0%

0-90 4,296.4 100%

90-180 0 0%

0-180 4,296.4 100%

Lumens Per ZoneZone Lumens % Total Zone Lumens % Total

0-10 1,115.6 26.0% 90-100 0 0%

10-20 1,573.2 36.6% 100-110 0 0%

20-30 921.7 21.5% 110-120 0 0%

30-40 620.8 14.4% 120-130 0 0%

40-50 65.1 1.5% 130-140 0 0%

50-60 0 0.0% 140-150 0 0%

60-70 0 0.0% 150-160 0 0%

70-80 0 0.0% 160-170 0 0%

80-90 0 0.0% 170-180 0 0%

Coefficients Of Utilization - Zonal Cavity MethodEffective Floor Cavity Reflectance: 20%

RCC %: 80 70 50 30 10 0

RW %:

RCR: 0

1

70 50 30 0

1.19 1.19 1.19 1.19

1.14 1.12 1.10 1.08

70 50 30 0

1.16 1.16 1.16 1.00

1.12 1.10 1.08 .96

50 30 20

1.11 1.11 1.11

1.06 1.05 1.03

50 30 20

1.06 1.06 1.06

1.02 1.01 1.00

50 30 20

1.02 1.02 1.02

.99 .98 .97

0

1.00

.96

Page 1 of 2Photometric Report: RLR-1-LS4-90-30K-M

1/19/2018file:///C:/ProgramData/PhotometricsPro/temp/RLR-1-LS4-90-30K-M_rep.htm

Filename: RLR-1-LS4-90-30K-MManufacturer: Stanpro

Luminaire: RLR-L

Luminaire Cat: RLR-1-L-S4-90-(A-H)-(B-W)-(B-S-W)-(B-S-W)-30K-M

Lamp: (1) COB VERO18-(BXRC-30G4000-C-73-SE) c/w Universal Driver D15CC55UNVTW-LS @ 120.00V

Distribution: Direct Type - Downlight

Lamp Output: Total luminaire Lumens: 4296.4

Max Candela: 13,544.0 at Horizontal: 0°, Vertical: 1°

Input Wattage: 52

Luminous Opening: Circular (Dia: 2.75")

Test: S1702171-R1

Test Lab: Spectra Lux Industries Inc.

Photometry : Type C

CIE Class: Direct

Cutoff Class: Full Cutoff

Nema Type: 4 X 4

Zonal Lumen SummaryZone Lumens % Luminaire

0-30 3,610.5 84%

0-40 4,231.3 98.5%

0-60 4,296.4 100%

60-90 0 0%

70-100 0 0%

90-120 0 0%

0-90 4,296.4 100%

90-180 0 0%

0-180 4,296.4 100%

Lumens Per ZoneZone Lumens % Total Zone Lumens % Total

0-10 1,115.6 26.0% 90-100 0 0%

10-20 1,573.2 36.6% 100-110 0 0%

20-30 921.7 21.5% 110-120 0 0%

30-40 620.8 14.4% 120-130 0 0%

40-50 65.1 1.5% 130-140 0 0%

50-60 0 0.0% 140-150 0 0%

60-70 0 0.0% 150-160 0 0%

70-80 0 0.0% 160-170 0 0%

80-90 0 0.0% 170-180 0 0%

Coefficients Of Utilization - Zonal Cavity MethodEffective Floor Cavity Reflectance: 20%

RCC %: 80 70 50 30 10 0

RW %:

RCR: 0

1

70 50 30 0

1.19 1.19 1.19 1.19

1.14 1.12 1.10 1.08

70 50 30 0

1.16 1.16 1.16 1.00

1.12 1.10 1.08 .96

50 30 20

1.11 1.11 1.11

1.06 1.05 1.03

50 30 20

1.06 1.06 1.06

1.02 1.01 1.00

50 30 20

1.02 1.02 1.02

.99 .98 .97

0

1.00

.96

Page 1 of 2Photometric Report: RLR-1-LS4-90-30K-M

1/19/2018file:///C:/ProgramData/PhotometricsPro/temp/RLR-1-LS4-90-30K-M_rep.htm

Filename: RLR-1-LS4-90-30K-SManufacturer: Stanpro

Luminaire: RLR-L

Luminaire Cat: RLR-1-L-S4-90-(A-H)-(B-W)-(B-S-W)-(B-S-W)-30K-S

Lamp: (1) COB VERO18-(BXRC-30G4000-C-73-SE) c/w Universal Driver D15CC55UNVTW-LS @ 120.00V

Distribution: Direct Type - Downlight

Lamp Output: Total luminaire Lumens: 4533.2

Max Candela: 17,911.0 at Horizontal: 0°, Vertical: 1°

Input Wattage: 52

Luminous Opening: Circular (Dia: 2.75")

Test: S1702205-R1

Test Lab: Spectra Lux Industries Inc.

Photometry : Type C

CIE Class: Direct

Cutoff Class: Full Cutoff

Nema Type: 4 X 4

Zonal Lumen SummaryZone Lumens % Luminaire

0-30 3,732.3 82.3%

0-40 4,434.3 97.8%

0-60 4,533.2 100%

60-90 0 0%

70-100 0 0%

90-120 0 0%

0-90 4,533.2 100%

90-180 0 0%

0-180 4,533.2 100%

Lumens Per ZoneZone Lumens % Total Zone Lumens % Total

0-10 1,438.0 31.7% 90-100 0 0%

10-20 1,446.3 31.9% 100-110 0 0%

20-30 848.0 18.7% 110-120 0 0%

30-40 701.9 15.5% 120-130 0 0%

40-50 99.0 2.2% 130-140 0 0%

50-60 0 0.0% 140-150 0 0%

60-70 0 0.0% 150-160 0 0%

70-80 0 0.0% 160-170 0 0%

80-90 0 0.0% 170-180 0 0%

Coefficients Of Utilization - Zonal Cavity MethodEffective Floor Cavity Reflectance: 20%

RCC %: 80 70 50 30 10 0

RW %:

RCR: 0

1

70 50 30 0

1.19 1.19 1.19 1.19

1.15 1.12 1.10 1.08

70 50 30 0

1.16 1.16 1.16 1.00

1.12 1.10 1.08 .96

50 30 20

1.11 1.11 1.11

1.06 1.05 1.03

50 30 20

1.06 1.06 1.06

1.02 1.01 1.00

50 30 20

1.02 1.02 1.02

.99 .98 .97

0

1.00

.96

Page 1 of 2Photometric Report: RLR-1-LS4-90-30K-S

1/19/2018file:///C:/ProgramData/PhotometricsPro/temp/RLR-1-LS4-90-30K-S_rep.htm

Filename: RLR-1-LS4-90-30K-SManufacturer: Stanpro

Luminaire: RLR-L

Luminaire Cat: RLR-1-L-S4-90-(A-H)-(B-W)-(B-S-W)-(B-S-W)-30K-S

Lamp: (1) COB VERO18-(BXRC-30G4000-C-73-SE) c/w Universal Driver D15CC55UNVTW-LS @ 120.00V

Distribution: Direct Type - Downlight

Lamp Output: Total luminaire Lumens: 4533.2

Max Candela: 17,911.0 at Horizontal: 0°, Vertical: 1°

Input Wattage: 52

Luminous Opening: Circular (Dia: 2.75")

Test: S1702205-R1

Test Lab: Spectra Lux Industries Inc.

Photometry : Type C

CIE Class: Direct

Cutoff Class: Full Cutoff

Nema Type: 4 X 4

Zonal Lumen SummaryZone Lumens % Luminaire

0-30 3,732.3 82.3%

0-40 4,434.3 97.8%

0-60 4,533.2 100%

60-90 0 0%

70-100 0 0%

90-120 0 0%

0-90 4,533.2 100%

90-180 0 0%

0-180 4,533.2 100%

Lumens Per ZoneZone Lumens % Total Zone Lumens % Total

0-10 1,438.0 31.7% 90-100 0 0%

10-20 1,446.3 31.9% 100-110 0 0%

20-30 848.0 18.7% 110-120 0 0%

30-40 701.9 15.5% 120-130 0 0%

40-50 99.0 2.2% 130-140 0 0%

50-60 0 0.0% 140-150 0 0%

60-70 0 0.0% 150-160 0 0%

70-80 0 0.0% 160-170 0 0%

80-90 0 0.0% 170-180 0 0%

Coefficients Of Utilization - Zonal Cavity MethodEffective Floor Cavity Reflectance: 20%

RCC %: 80 70 50 30 10 0

RW %:

RCR: 0

1

70 50 30 0

1.19 1.19 1.19 1.19

1.15 1.12 1.10 1.08

70 50 30 0

1.16 1.16 1.16 1.00

1.12 1.10 1.08 .96

50 30 20

1.11 1.11 1.11

1.06 1.05 1.03

50 30 20

1.06 1.06 1.06

1.02 1.01 1.00

50 30 20

1.02 1.02 1.02

.99 .98 .97

0

1.00

.96