![Page 1: CONTINUOUS EMISSION MONITORINGcdn.cseindia.org/userfiles/Particulate_Matter_CEMS...nt Particles in the extracted partial gas flow are collected on a filter paper in defined time intervals](https://reader034.fdocuments.in/reader034/viewer/2022042023/5e7b9ac33f4ca3416d59c170/html5/thumbnails/1.jpg)
nt CONTINUOUS EMISSION MONITORING SOLUTIONS
NAME: Sankar Kannan
DATE: August 09, 2016
![Page 2: CONTINUOUS EMISSION MONITORINGcdn.cseindia.org/userfiles/Particulate_Matter_CEMS...nt Particles in the extracted partial gas flow are collected on a filter paper in defined time intervals](https://reader034.fdocuments.in/reader034/viewer/2022042023/5e7b9ac33f4ca3416d59c170/html5/thumbnails/2.jpg)
nt
PM CEMS - HISTORY
Date Name | Confidential 2
RINGELMANN SCALE
![Page 3: CONTINUOUS EMISSION MONITORINGcdn.cseindia.org/userfiles/Particulate_Matter_CEMS...nt Particles in the extracted partial gas flow are collected on a filter paper in defined time intervals](https://reader034.fdocuments.in/reader034/viewer/2022042023/5e7b9ac33f4ca3416d59c170/html5/thumbnails/3.jpg)
nt
Opacity (%)
PM CEMS
RINGELMANN SCALE
HISTORY
![Page 4: CONTINUOUS EMISSION MONITORINGcdn.cseindia.org/userfiles/Particulate_Matter_CEMS...nt Particles in the extracted partial gas flow are collected on a filter paper in defined time intervals](https://reader034.fdocuments.in/reader034/viewer/2022042023/5e7b9ac33f4ca3416d59c170/html5/thumbnails/4.jpg)
nt
Filter paper slot
Sampling pipe
Pump
Reference scale
PM CEMS - HISTORY
BACHARACH SCALE – SOOT NUMBER
![Page 5: CONTINUOUS EMISSION MONITORINGcdn.cseindia.org/userfiles/Particulate_Matter_CEMS...nt Particles in the extracted partial gas flow are collected on a filter paper in defined time intervals](https://reader034.fdocuments.in/reader034/viewer/2022042023/5e7b9ac33f4ca3416d59c170/html5/thumbnails/5.jpg)
nt
CEMS
CEMS
PM / DUST
TECHNIQUE
Elec.Dyn.
SCATTER LIGHT
OPACITY
GRAVIMETRIC
INSTALLATION
IN-SITU
WET EXTRACTIVE
GAS
EXTRACTIVE
COLD DRY HOT WET DRY DILUTION
IN-STACK
OUT OF STACK
IN-SITU
PROBE
CROSS STACK
VARIOUS TECHNOLOGIES
![Page 6: CONTINUOUS EMISSION MONITORINGcdn.cseindia.org/userfiles/Particulate_Matter_CEMS...nt Particles in the extracted partial gas flow are collected on a filter paper in defined time intervals](https://reader034.fdocuments.in/reader034/viewer/2022042023/5e7b9ac33f4ca3416d59c170/html5/thumbnails/6.jpg)
nt
Colliding particles exchange their
electrical charge with the measuring
electrode. The electrical charge
transfer depends on the respective
mass, velocity and electric charge of the
particles
This effect is used by the so-called “Tribo flow
effect”
PM CEMS - TECHNOLOGIES
TRIBO FLOW
![Page 7: CONTINUOUS EMISSION MONITORINGcdn.cseindia.org/userfiles/Particulate_Matter_CEMS...nt Particles in the extracted partial gas flow are collected on a filter paper in defined time intervals](https://reader034.fdocuments.in/reader034/viewer/2022042023/5e7b9ac33f4ca3416d59c170/html5/thumbnails/7.jpg)
nt
IAC = measured AC-current (A)
KI = const., function of the geometry of
the stack
KM = material-dependent
m = mass-concentration of particulates (mg/s)
Source: Lecture K. Smolders and J. Baeyens, Belgium, I
IAC = KI • KM • m
Particles procedure a charge movement
by charge induction.
(Charge on the particle transfer charge in
the probe as it passes.)
PM CEMS - TECHNOLOGIES
ELECTRODYNAMIC
![Page 8: CONTINUOUS EMISSION MONITORINGcdn.cseindia.org/userfiles/Particulate_Matter_CEMS...nt Particles in the extracted partial gas flow are collected on a filter paper in defined time intervals](https://reader034.fdocuments.in/reader034/viewer/2022042023/5e7b9ac33f4ca3416d59c170/html5/thumbnails/8.jpg)
nt
PM CEMS - TECHNOLOGIES
Points to ponder
Triboelectric / Triboflow / Electrodynamic is velocity dependent. So not
suitable for any process where there is a variation in the velocity.
Mostly suitable for mass flow measurement and not for instantaneous
concentration measurement.
Widely used as a switch for detection of filter bag rupture
Internal Zero & Span check is not possible
TRIBO FLOW & ELECTRODYNAMIC
![Page 9: CONTINUOUS EMISSION MONITORINGcdn.cseindia.org/userfiles/Particulate_Matter_CEMS...nt Particles in the extracted partial gas flow are collected on a filter paper in defined time intervals](https://reader034.fdocuments.in/reader034/viewer/2022042023/5e7b9ac33f4ca3416d59c170/html5/thumbnails/9.jpg)
nt
Particles in the extracted partial gas flow are collected
on a filter paper in defined time intervals (approx. 5 min).
Beta-radiation on the filter paper provides measured
values directly proportional to the dust weight, not
influenced by particle size and color.
Device provides only mean values (normally 5 to 20 min),
no information about actual measured values
Radiation source needs high safety effort
High costs for consumables
PM CEMS - TECHNOLOGIES BETA RADIATION
![Page 10: CONTINUOUS EMISSION MONITORINGcdn.cseindia.org/userfiles/Particulate_Matter_CEMS...nt Particles in the extracted partial gas flow are collected on a filter paper in defined time intervals](https://reader034.fdocuments.in/reader034/viewer/2022042023/5e7b9ac33f4ca3416d59c170/html5/thumbnails/10.jpg)
nt
reflection
diffraction
absorption
light
refraction
“Fortschritt-Berichte VDI” Reihe 8, Nr. 773, Düsseldorf: VDI Verlag 1999
PM CEMS - TECHNOLOGIES DIFFERENT EFFECTS OCCURRING WHEN ILLUMINATING A
PARTICLE
![Page 11: CONTINUOUS EMISSION MONITORINGcdn.cseindia.org/userfiles/Particulate_Matter_CEMS...nt Particles in the extracted partial gas flow are collected on a filter paper in defined time intervals](https://reader034.fdocuments.in/reader034/viewer/2022042023/5e7b9ac33f4ca3416d59c170/html5/thumbnails/11.jpg)
nt
Transmission
oI
IT
Opacity
oI
IOpac 1
I = received light;
Io = emitted light
k = extinction coefficient
E = extinction
c = dust concentration
L = length of optical measurement path
(auto-collimating: 2 x distance)
Extinction
TE
1lg
PM CEMS - TECHNOLOGIES
TRANSMITTANCE / OPACITY
Dust concentration is proportional to Extinction
![Page 12: CONTINUOUS EMISSION MONITORINGcdn.cseindia.org/userfiles/Particulate_Matter_CEMS...nt Particles in the extracted partial gas flow are collected on a filter paper in defined time intervals](https://reader034.fdocuments.in/reader034/viewer/2022042023/5e7b9ac33f4ca3416d59c170/html5/thumbnails/12.jpg)
nt
PM CEMS - TECHNOLOGIES
12
MEASURING LIMITS – TRANSMISSION / OPACITY
Relationship between - path length
- particle size
- dust concentration
To measure low concentrations a long measuring path is required
Smallest measuring ranges Largest measuring ranges
![Page 13: CONTINUOUS EMISSION MONITORINGcdn.cseindia.org/userfiles/Particulate_Matter_CEMS...nt Particles in the extracted partial gas flow are collected on a filter paper in defined time intervals](https://reader034.fdocuments.in/reader034/viewer/2022042023/5e7b9ac33f4ca3416d59c170/html5/thumbnails/13.jpg)
nt
PM CEMS - TECHNOLOGIES
Date Name | Confidential 13
SCATTER LIGHT
![Page 14: CONTINUOUS EMISSION MONITORINGcdn.cseindia.org/userfiles/Particulate_Matter_CEMS...nt Particles in the extracted partial gas flow are collected on a filter paper in defined time intervals](https://reader034.fdocuments.in/reader034/viewer/2022042023/5e7b9ac33f4ca3416d59c170/html5/thumbnails/14.jpg)
nt
transmitted light
particle
scattered light intensity
light trap
90°-area
forward scattering area(0°)
backward scattering area (180°)
small angel measurement
wide angel measurement
“Fortschritt-Berichte VDI” Reihe 8, Nr. 773, Düsseldorf: VDI Verlag 1999
PM CEMS - TECHNOLOGIES DIFFERENT REGIONS OF SCATTERED LIGHT
![Page 15: CONTINUOUS EMISSION MONITORINGcdn.cseindia.org/userfiles/Particulate_Matter_CEMS...nt Particles in the extracted partial gas flow are collected on a filter paper in defined time intervals](https://reader034.fdocuments.in/reader034/viewer/2022042023/5e7b9ac33f4ca3416d59c170/html5/thumbnails/15.jpg)
nt
Dust concentration in mg/m³
Calibration according to the
recommendation of the
Guideline VDI 2066.
Measurement volume
Detector
Light
emitter
Direct measured light scattered
from particles
Small scattered light intensity
requires high measurement
accuracy and sensitivity
PM CEMS - TECHNOLOGIES
FORWARD SCATTER LIGHT
![Page 16: CONTINUOUS EMISSION MONITORINGcdn.cseindia.org/userfiles/Particulate_Matter_CEMS...nt Particles in the extracted partial gas flow are collected on a filter paper in defined time intervals](https://reader034.fdocuments.in/reader034/viewer/2022042023/5e7b9ac33f4ca3416d59c170/html5/thumbnails/16.jpg)
nt
PM CEMS - TECHNOLOGIES
: Name (Date) 16
BACKWARD SCATTER LIGHT
Sender
Receiver
Measuring volume
![Page 17: CONTINUOUS EMISSION MONITORINGcdn.cseindia.org/userfiles/Particulate_Matter_CEMS...nt Particles in the extracted partial gas flow are collected on a filter paper in defined time intervals](https://reader034.fdocuments.in/reader034/viewer/2022042023/5e7b9ac33f4ca3416d59c170/html5/thumbnails/17.jpg)
nt
PM CEMS - TECHNOLOGIES
Points to ponder
Both these opto-electric measurement are time tested and used for a long
time
Transmissiometers are suitable for medium to high concentration of dust.
Scatterlight instruments are used for measurement of very low to medium
concentration of dust
Various standards are available for dust monitors based on these
measurement principles
TRANSMISSIOMETER & SCATTERLIGHT MEASUREMENT
![Page 18: CONTINUOUS EMISSION MONITORINGcdn.cseindia.org/userfiles/Particulate_Matter_CEMS...nt Particles in the extracted partial gas flow are collected on a filter paper in defined time intervals](https://reader034.fdocuments.in/reader034/viewer/2022042023/5e7b9ac33f4ca3416d59c170/html5/thumbnails/18.jpg)
nt
Installation
support Filter head probe GS5
Multichannel hose
Evaluation unit
Probe mount
Dust collector
Laptop (only SHC 502)
PM CEMS - TECHNOLOGIES
GRAVIMETRIC MEASUREMENT – REFERENCE MEASUREMENT
![Page 19: CONTINUOUS EMISSION MONITORINGcdn.cseindia.org/userfiles/Particulate_Matter_CEMS...nt Particles in the extracted partial gas flow are collected on a filter paper in defined time intervals](https://reader034.fdocuments.in/reader034/viewer/2022042023/5e7b9ac33f4ca3416d59c170/html5/thumbnails/19.jpg)
nt
Measuring principle Type Procedure
Gravimetric measurement extractive discontinuous
Beta Ray extractive discontinuous
Scatter light wet gas extractive continuous
Scatter light dry gas in - situ continuous
Triboflow in - situ continuous
Transmission in - situ continuous
PM CEMS - TECHNOLOGIES SUMMARY
![Page 20: CONTINUOUS EMISSION MONITORINGcdn.cseindia.org/userfiles/Particulate_Matter_CEMS...nt Particles in the extracted partial gas flow are collected on a filter paper in defined time intervals](https://reader034.fdocuments.in/reader034/viewer/2022042023/5e7b9ac33f4ca3416d59c170/html5/thumbnails/20.jpg)