Contents · rc.pER _ Eussmann 5001/ac T1ME-DELAY FUSE FNQ-10 Low voltage, supplementary fuses 3...
-
Upload
duongxuyen -
Category
Documents
-
view
218 -
download
0
Transcript of Contents · rc.pER _ Eussmann 5001/ac T1ME-DELAY FUSE FNQ-10 Low voltage, supplementary fuses 3...
• r_c.pER Eussmann
5001/ac T1ME-DELAY
FUSE
FNQ-10
Low voltage, supplementary fuses 3
Contents Description Fuse holder and block selection guide
Cable limiters and welder limiters
K cable limiters 600V UH cable limiters 250V 64000 and 68000 welder limiters . 600V
13/32-x 1 1/2-Fast-acting supplementary fuses BAF 250V 3-5 KTK 600V 3-5 KLM 600Vac/dc 3-6
13/32-x 1 1/2-Time-delay supplementary fuses FNM 250V 3-7
FNQ 500V 3-7
13/32-x 1 3/8-Fast-acting supplementary fuses BBS 600V 3-8
Pin indication fuses and actuator GBA 125V 3-8 GLD 125V 3-8 MIC 250V fast-acting 3-9 FNA 250V time-delay 3-9 MIS 600V 3-10 KAZ 600V 3-10
Limiters
ANN . 125V fast-acting 3-10 ANL 80Vdc time-delay 3-10 4164 and 4164-FR fuse blocks .3-10
In-line size rejecting fuses and fuse holders GLQ 300V 3-11
GMQ 300V 3-11
In-line non-rejecting fuses and fuse holders GLR 300V 3-12 GMF 300V 3-12
GRF 300V 3-12
Automotive blade-type fuses ATC 32Vdc 3-13 ATC- _ID 32Vdc 3-13 ATM 32Vdc 3-13 ATM- _ID 32Vdc 3-13 ATM-LP 32Vdc 3-13 ATR micro 32Vdc 3-16 MAX 32Vdc 3-14 MAX- _ID 32Vdc 3-14
Automotive blade-type fuse holders HHC, HHD, HHF, HHG, ATC-FHID for ATC fuses . . 3-13 HHL, HHM, ATC-FHID for ATM fuses 3-14 HHX for MAX fuses 3-14
Page 3-2
3-4 3-4
3-4
RED indicates NEW information PCB fuseclips for ATC/ATM blade, 5mm, 1/4" and 13/32" diameter fuses 3-15
BUSSMANN SERIES FULL LINE CATALOG 1007—July 2015 Eaton.corn/bussmannseries 3.1 3-1
Low voltage
supplementary
fuses
3Low voltage, supplementary fuses
BUSSMANN SERIES FULL LINE CATALOG 1007—July 2015 Eaton.com/bussmannseries
Description PageFuse holder and block selection guide 3-2
Cable limiters and welder limitersK cable limiters . . . . . . . . . . . . . . . 600V . . . . . . . . . . 3-4UH cable limiters . . . . . . . . . . . . . . 250V . . . . . . . . . . 3-464000 and 68000 welder limiters . . 600V . . . . . . . . . . 3-4
13/32˝ x 1 1/2˝ Fast-acting supplementary fusesBAF . . . . . . . . . . . . . . . . . . . . . . 250V . . . . . . . . . . 3-5KTK . . . . . . . . . . . . . . . . . . . . . . 600V . . . . . . . . . . 3-5KLM . . . . . . . . . . . . . . . . . . 600Vac/dc . . . . . . . . . . 3-6
13/32˝ x 1 1/2˝ Time-delay supplementary fusesFNM . . . . . . . . . . . . . . . . . . . . . . 250V . . . . . . . . . . 3-7FNQ . . . . . . . . . . . . . . . . . . . . . . . 500V . . . . . . . . . . 3-7
13/32˝ x 1 3/8˝ Fast-acting supplementary fusesBBS . . . . . . . . . . . . . . . . . . . . . . . 600V . . . . . . . . . . 3-8
Pin indication fuses and actuatorGBA . . . . . . . . . . . . . . . . . . . . . . .125V . . . . . . . . . . 3-8GLD . . . . . . . . . . . . . . . . . . . . . . . 125V . . . . . . . . . . 3-8MIC . . . . . . . . . . . . . . . 250V fast-acting . . . . . . . . . . 3-9FNA . . . . . . . . . . . . . . . 250V time-delay . . . . . . . . . . 3-9MIS . . . . . . . . . . . . . . . . . . . . . . . 600V . . . . . . . . . 3-10KAZ . . . . . . . . . . . . . . . . . . . . . . . 600V . . . . . . . . . 3-10
LimitersANN . . . . . . . . . . . . . . 125V fast-acting . . . . . . . . . 3-10ANL . . . . . . . . . . . . . . 80Vdc time-delay . . . . . . . . . 3-104164 and 4164-FR . . . . . . . .fuse blocks . . . . . . . . . 3-10
In-line size rejecting fuses and fuse holdersGLQ . . . . . . . . . . . . . . . . . . . . . . 300V . . . . . . . . . .3-11GMQ . . . . . . . . . . . . . . . . . . . . . . 300V . . . . . . . . . .3-11
In-line non-rejecting fuses and fuse holdersGLR . . . . . . . . . . . . . . . . . . . . . . 300V . . . . . . . . . 3-12GMF . . . . . . . . . . . . . . . . . . . . . . 300V . . . . . . . . . 3-12GRF . . . . . . . . . . . . . . . . . . . . . . 300V . . . . . . . . . 3-12
Automotive blade-type fusesATC . . . . . . . . . . . . . . . . . . . . . . 32Vdc . . . . . . . . . 3-13ATC-_ID . . . . . . . . . . . . . . . . . . . 32Vdc . . . . . . . . . 3-13ATM . . . . . . . . . . . . . . . . . . . . . . 32Vdc . . . . . . . . . 3-13ATM-_ID . . . . . . . . . . . . . . . . . . . 32Vdc . . . . . . . . . 3-13ATM-LP . . . . . . . . . . . . . . . . . . . .32Vdc . . . . . . . . . 3-13ATR micro . . . . . . . . . . . . . . . . . 32Vdc . . . . . . . . . 3-16MAX . . . . . . . . . . . . . . . . . . . . . . 32Vdc . . . . . . . . . 3-14MAX-_ID . . . . . . . . . . . . . . . . . . . 32Vdc . . . . . . . . . 3-14
Automotive blade-type fuse holdersHHC, HHD, HHF, HHG, ATC-FHID for ATC fuses . . . 3-13HHL, HHM, ATC-FHID for ATM fuses . . . . . . . . . . . .3-14HHX for MAX fuses . . . . . . . . . . . . . . . . . . . . . . . . .3-14PCB fuseclips for ATC/ATM blade, 5mm, 1/4˝ and 13/32˝ diameter fuses . . . . . . . . . . . . . . . 3-15
Contents
RED indicates NEW information
HM250 CH Safety JTM' Modular Type
JM600 HM600
• . -
• •
C.,
OPM-1038R and CH 0 PM-1038RSW
HPC-D
alma HPM
HEB HPF
HEX and HEY
NDNF1-WH BCM CCP Class CC
JP 4164 and 4164-FR
Modular knifeblade
OPM-NG-SC3
• 0
3 Low voltage, supplementary fuses Holders and blocks for low voltage supplementary fuses
Limiters
Catalog number Volts Page K 600V 3-4 u11 250V 3-4 68000 600V 3-4 64000 600V 3-4 ANN fast-acting limiter 125Vac/80Vdc 3-10 ANL time-delay limiter 80Vdc 3-10
Holders • CH Class J modular 1- to 3-pole, panel/DIN-Rail mount 9-11 • Safety JTM' modular holders, panel/DIN-Rail mount 9-14
Blocks • Modular type fuse blocks 250/600V, panel mount 9-41 • HM250 1- to 3-pole 250V, panel/DIN-Rail mount 9-24 • HM600 1- to 3-pole 600V, panel/DIN-Rail mount 9-24
Blocks • Modular knifeblade fuse blocks 250/600V, panel mount 9-17 • Modular type fuse blocks 600V, panel mount 9-41 • JM600 panel/DIN-Rail mount 9-24 • JP pyramid blocks, panel mount 9-31 • BH modular-style open blocks, panel mount 9-41
Limiter blocks - ANN and ANL • Blocks for 4164 and 4164-FR 3-10
13/32-X 1 112-Fuses
Catalog number Volts Page BAF 250V 3-5 KTK 600V 3-5 KLM 600Vac/dc 3-6 FN M 250V 3-7 FNQ 500V 3-7
Holders • OPM-NG-SC3 3-pole, panel/DIN-Rail mount 9-12 • OPM-1038R 3-pole, panel/DIN-Rail mount 9-11 • OPM-1038RSW 3-pole w/ switch, panel/DIN-Rail mount 9-10 • CH global 1- to 3-pole, DIN-Rail mount 9-2 • HPG panel mount fuse holder 9-53 • HPC-D panel mount fuse holder 9-54 • HPM panel mount fuse holder 9-54 • HPS panel mount fuse holder 9-53 • HPF panel mount fuse holder 9-53 • HEB 1-pole in-line fuse holder 9-46 • HEX and HEY 2-pole in-line fuse holders 9-45 • NDNF1-WH fuse holding rail mount terminal block 9-58 • Compact Circuit Protector (CCP) Class CC 1-, 2-, 3-pole
disconnect switch. 12-2
Blocks • BCM panel/DIN-Rail with adapters 9-32 • 4421 and 4515 single-pole fuse blocks 9-57
3-2 BUSSMANN SERIES FULL LINE CATALOG 1007—July 2015 Eaton.corn/bussmannseries 3-2 BUSSMANN SERIES FULL LINE CATALOG 1007—July 2015 Eaton.com/bussmannseries
3 Low voltage, supplementary fusesHolders and blocks for low voltage supplementary fuses
13/32˝ X 1 1/2˝ Fuses
Catalog number Volts PageBAF . . . . . . . . . . . . . . . . . . . . . . . 250V . . . . . . . . . . . . . . . . . . . . . 3-5KTK . . . . . . . . . . . . . . . . . . . . . . . 600V . . . . . . . . . . . . . . . . . . . . . 3-5KLM. . . . . . . . . . . . . . . . . . . . . . . 600Vac/dc . . . . . . . . . . . . . . . . . 3-6FNM . . . . . . . . . . . . . . . . . . . . . . 250V . . . . . . . . . . . . . . . . . . . . . 3-7FNQ . . . . . . . . . . . . . . . . . . . . . . . 500V . . . . . . . . . . . . . . . . . . . . . 3-7
Holders• OPM-NG-SC3 3-pole, panel/DIN-Rail mount . . . . . . . . . . . . . . . . . . .9-12• OPM-1038R 3-pole, panel/DIN-Rail mount . . . . . . . . . . . . . . . . . . . . 9-11• OPM-1038RSW 3-pole w/ switch, panel/DIN-Rail mount . . . . . . . . . .9-10• CH global 1- to 3-pole, DIN-Rail mount . . . . . . . . . . . . . . . . . . . . . . .9-2• HPG panel mount fuse holder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9-53• HPC-D panel mount fuse holder . . . . . . . . . . . . . . . . . . . . . . . . . . . .9-54• HPM panel mount fuse holder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9-54• HPS panel mount fuse holder. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9-53• HPF panel mount fuse holder. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9-53• HEB 1-pole in-line fuse holder. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9-46• HEX and HEY 2-pole in-line fuse holders . . . . . . . . . . . . . . . . . . . . .9-45• NDNF1-WH fuse holding rail mount terminal block . . . . . . . . . . . . . .9-58• Compact Circuit Protector (CCP) Class CC 1-, 2-, 3-pole disconnect switch. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12-2
Blocks• BCM panel/DIN-Rail with adapters . . . . . . . . . . . . . . . . . . . . . . . . . . .9-32• 4421 and 4515 single-pole fuse blocks . . . . . . . . . . . . . . . . . . . . . . .9-57
OPM-NG-SC3 CH
CH
JM600
JP BH 4164 and 4164-FR
Safety J™ ModularType
HM250
HM600
OPM-1038R and OPM-1038RSW
Limiters
Catalog number Volts PageK . . . . . . . . . . . . . . . . . . . . . . . . . 600V . . . . . . . . . . . . . . . . . . . . . 3-4UH . . . . . . . . . . . . . . . . . . . . . . . . 250V . . . . . . . . . . . . . . . . . . . . . 3-468000 . . . . . . . . . . . . . . . . . . . . . 600V . . . . . . . . . . . . . . . . . . . . . 3-464000 . . . . . . . . . . . . . . . . . . . . . 600V . . . . . . . . . . . . . . . . . . . . . 3-4ANN fast-acting limiter . . . . . . . . . 125Vac/80Vdc . . . . . . . . . . . . . 3-10ANL time-delay limiter . . . . . . . . . 80Vdc . . . . . . . . . . . . . . . . . . . 3-10
Holders• CH Class J modular 1- to 3-pole, panel/DIN-Rail mount. . . . . . . . . . .9-11• Safety J™ modular holders, panel/DIN-Rail mount . . . . . . . . . . . . . . .9-14
Blocks• Modular type fuse blocks 250/600V, panel mount. . . . . . . . . . . . . . . .9-41• HM250 1- to 3-pole 250V, panel/DIN-Rail mount . . . . . . . . . . . . . . . .9-24• HM600 1- to 3-pole 600V, panel/DIN-Rail mount . . . . . . . . . . . . . . . .9-24
Blocks• Modular knifeblade fuse blocks 250/600V, panel mount . . . . .9-17• Modular type fuse blocks 600V, panel mount . . . . . . . . . . . . . . . . . . .9-41• JM600 panel/DIN-Rail mount . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-24• JP pyramid blocks, panel mount . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-31• BH modular-style open blocks, panel mount . . . . . . . . . . . . . . . . . . . 9-41
Limiter blocks - ANN and ANL• Blocks for 4164 and 4164-FR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-10
HPGHPC-D HPM
HPS HPF HEB
HEX andHEY
NDNF1-WH BCM
Modular knifeblade
CCPClass CC
1/4"X 1 1/4"fuse catalog numbers Volts Page GBA 1/4" X 1 1/4" 125V 3-8 GLD 1/4" X 1 1/4" 125V 3-8 MIC 13/32" X 1 1/2" 250V 3-9 FNA 13/32" X 1 1/2" 250V 3-9 MIS 13/32" X 2" 600V 3-10
KAZ 13/32" X 2' 600V 3-10 *Not a fuse. Pin actuator only.
Holders
Catalog numbers Volts Page ATC 32Vdc 3-13 ATM 32Vdc 3-13 MAX 32Vdc 3-14
Holders • ATC: HHC, HHD, HHF, HHG and ATC-FHID In-line holders 3-13 • ATM: HHL, HHM and ATM-FHID In-line holders 3-14 • MAX: HHX, MAX-FHID In-line holders 3-14
In-line rejecting and non-rejecting fuses
Catalog number Volts Page GLQ rejecting fuse 300V 3-11 GMQ rejecting fuse 300V 3-11 GLR non-rejecting fuse 300V 3-12 GMF non-rejecting fuse 300V 3-12 GRF non-rejecting fuse 300V 3-12
Holders • GLQ and GMQ: HLQ rejection holder 3-11 • GLR, GMF and GRF: HLR and HLR-2A non-rejection holders 3-12
easylDTm HHC, HHD, HHF HHL and
HHX illuminating holders and HHG HHM
11. HLQ3 fuse holders HLR fuse holder
Holders and blocks for low voltage supplementary fuses
3 13132" X 1 318" Fuses
Catalog numbers Volts Page BBS 600V 3-8
Holder • HPS-L panel mount holder 9-53 ,,,„ . :::.k_. 1.,. 4 .
) A
Blocks • BCM panel/DIN-Rail with adapters 9-32 HPS-L BCM
• 4421 and 4515 single-pole fuse blocks 9-57
Pin indicating fuses
• 1/4" X 1/4": HLD panel mount visual indication 9-52 FEW HK • 1/4" X 1/4": HK panel mount lamp indicating 9-52
Blocks • 1/4" X 1 1/4": 8000 for visual indication 9-55 • 13/32" X 1 1/7: 4-pole signal block cat # 3839
(not shown in catalog)* • 13/32" X 2": 1-pole signal block cat # 2778
(not shown in catalog)* • 13/37 X 2": 2-pole signal block cat # 2837
(not shown in catalog)* • 13/32" X 2": 3-pole signal block cat # 2838
(not shown in catalog)*
Automotive blade-type fuses
BUSSMANN SERIES FULL LINE CATALOG 1007—July 2015 Eaton.corn/bussmannseries 3-3 3-3
Low voltage
supplementary
fuses
3Low voltage, supplementary fusesHolders and blocks for low voltage supplementary fuses
BUSSMANN SERIES FULL LINE CATALOG 1007—July 2015 Eaton.com/bussmannseries
In-line rejecting and non-rejecting fuses
Catalog number Volts PageGLQ rejecting fuse . . . . . . . . . . . . . . . . . . . 300V . . . . . . . . . . . . . . . 3-11GMQ rejecting fuse . . . . . . . . . . . . . . . . . . 300V . . . . . . . . . . . . . . . 3-11GLR non-rejecting fuse . . . . . . . . . . . . . . . 300V . . . . . . . . . . . . . . . 3-12GMF non-rejecting fuse . . . . . . . . . . . . . . . 300V . . . . . . . . . . . . . . . 3-12GRF non-rejecting fuse . . . . . . . . . . . . . . . 300V . . . . . . . . . . . . . . . 3-12
Holders• GLQ and GMQ: HLQ rejection holder . . . . . . . . . . . . . . . . . . . . . . . . 3-11• GLR, GMF and GRF: HLR and HLR-2A non-rejection holders . . . . . . . 3-12
13/32˝ X 1 3/8˝ Fuses
Catalog numbers Volts PageBBS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 600V . . . . . . . . . . . . . . . 3-8
Holder• HPS-L panel mount holder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-53
Blocks• BCM panel/DIN-Rail with adapters . . . . . . . . . . . . . . . . . . . . . . . . . . 9-32• 4421 and 4515 single-pole fuse blocks . . . . . . . . . . . . . . . . . . . . . . 9-57
Automotive blade-type fuses
Catalog numbers Volts PageATC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32Vdc . . . . . . . . . . . . . . 3-13ATM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32Vdc . . . . . . . . . . . . . . 3-13MAX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32Vdc . . . . . . . . . . . . . . 3-14
Holders• ATC: HHC, HHD, HHF, HHG and ATC-FHID In-line holders . . . . . . . . 3-13• ATM: HHL, HHM and ATM-FHID In-line holders . . . . . . . . . . . . . . . . 3-14• MAX: HHX, MAX-FHID In-line holders . . . . . . . . . . . . . . . . . . . . . . . 3-14
Pin indicating fuses
1/4˝ X 1 1/4˝ fuse catalog numbers VoltsPageGBA 1/4" X 1 1/4" . . . . . . . . . . . . . . . . . . . 125V . . . . . . . . . . . . . . . 3-8GLD 1/4" X 1 1/4" . . . . . . . . . . . . . . . . . . . 125V . . . . . . . . . . . . . . . 3-8MIC 13/32" X 1 1/2" . . . . . . . . . . . . . . . . . 250V . . . . . . . . . . . . . . . 3-9FNA 13/32" X 1 1/2˝ . . . . . . . . . . . . . . . . . 250V . . . . . . . . . . . . . . . 3-9MIS 13/32" X 2˝ . . . . . . . . . . . . . . . . . . . . 600V . . . . . . . . . . . . . . . 3-10
KAZ 13/32" X 2˝* . . . . . . . . . . . . . . . . . . . 600V . . . . . . . . . . . . . . . 3-10*Not a fuse. Pin actuator only.
Holders• 1/4" X 1/4": HLD panel mount visual indication . . . . . . . . . . . . . . . . 9-52• 1/4" X 1/4": HK panel mount lamp indicating. . . . . . . . . . . . . . . . . . . 9-52
Blocks• 1/4" X 1 1/4": 8000 for visual indication . . . . . . . . . . . . . . . . . . . . . 9-55• 13/32" X 1 1/2": 4-pole signal block cat. # 3839 (not shown in catalog)*
• 13/32" X 2˝: 1-pole signal block cat. # 2778 (not shown in catalog)*
• 13/32" X 2˝: 2-pole signal block cat. # 2837 (not shown in catalog)*
• 13/32" X 2˝: 3-pole signal block cat. # 2838 (not shown in catalog)*
HPS-L BCM
HLD
HK
8000
HHC, HHD, HHFand HHG
easy ID™illuminating holders
HHX
HLQ3 fuse holders HLR fuse holder
HHL andHHM
3 Low voltage, supplementary fuses Cable limiters and welder limiters
K 600V UH 250V
250kcmil KCH
350kcmil KGJ',2
500kcmil KCM'"'"
600kcmil KCV
750kcmil KCR' '
1000kcmil KCS
KFT 250kcmil KFM'
750kcmil
2/OAWG 4/OAWG UHA
UHJ-M 3/OAWG 250kcmil
350kcmil 500kcmil UHJ-T
600kcmil 800kcmil UHJ-W
■ 64000 and 68000
Specifications: Description: Welder limiters.
Ratings:
Volts — 600Vac (or less) IR — 200kA RMS Sym.
Catalog numbers Catalog Fuse holder Nominal
type amp rating
Class H
300
Class H
600
64200 Class J 200
64300 Class J 300
KCF
*Tubular terminal and offset bolt-type terminal KQV #12 KDD 2/0
KQT #10 KDE 3/0
KFZ #8 KDF 4/0
KIG #6 KDH 250kcmil
KDY #4 KDJ• 350kcmil
KDA #2 KDM 1,S 500kcmil
KDB #1 KDU 600kcmil
KDC 1/0 750kcmil
*Compression connector rod and tubular terminals KEX 4/0 KQO 350kcmil
KFH-A 250kcmil KDT 500kcmil
**Center bolt-type terminal and off-set bolt-type terminal KPF 4/0 KDP' 500kcmil
KEW 350kcmil
Copper conductors only. **Copper or aluminum conductors.
'UL Listed (File E90818), 600Vac, 200k A I.R.. 'Available with shrink tube " V" suffix. •Available with molded rubber boots. Boot can be purchased separately, order Part# - BOOT-KCM.
Accessories Boots can be purchased separately.
For KCM BOOT-KCM For KDM BOOT-KDM
Installation tools can be purchased separately from Thomas and Betts
• Crimp Tool: TBM-14M • Die: 15506 KDM/15515 KDR
Data Sheet: 1042
Catalog numbers Center bolt-type terminal and off-set bolt-type terminal Catalog Copper cable Aluminum cable number size size
Features and benefits: • Current-limiting devices designed specially for use
on welder circuits only • Time-current characteristics are designed to hold
on the intermittent overloading encountered in welder operation, while providing short-circuit protection to the circuit and equipment
• Typical applications: • Welder circuits • Because welder limiters have special characteristics, they are
not intended for application on general-use circuits
Recommended fuse blocks for 68000 and 64000 limiters • See page 3-2
Data Sheet: 1045
Typical applications: • Protecting low voltage distribution and service entrance
cables against short-circuit currents. Catalog numbers
Catalog number
Typical applications: • Designed specifically for use in residental applications.
Catalog number
Cable size
*Tubular terminals KCY #4
KCZ #3
KCA #2
KCB #1
KCC 1/0
KCD1,2 2/0
KCE 3/0
4/0
Cable size
numbers 68300
68600
3-4 BUSSMANN SERIES FULL LINE CATALOG 1007—July 2015 Eaton.corn/bussmannseries
UHA
Cable . Limiter
UH.J.T ''.1.1110110if
1.10.0
Specifications: Description: Cable limiters.
Ratings:
Volts — up to 250Vac IR — 100kA RMS Sym.
Terminals: • Center bolt-to-offset bolt - copper or aluminum conductors.
Conductors: • Copper or aluminum conductors are permitted per the listed
cable size. Select the catalog symbol for the system conductor size. See data sheet 1042 for dimensions.
Specifications: Description: Cable limiters. Ratings:
Volts — 600Vac IR — 200kA RMS Sym.
600Vac Agency information: UL Listing: KDM, KDR, KDP and KFM, KCM, KCM-B and KCR.
Features and benefits: • Sizes and ratings available to
meet many applications.
3-4 BUSSMANN SERIES FULL LINE CATALOG 1007—July 2015 Eaton.com/bussmannseries
3 Low voltage, supplementary fusesCable limiters and welder limiters
K 600V
Specifications:Description: Cable limiters.Ratings:Volts — 600VacIR — 200kA RMS Sym.
@ 600VacAgency information: ULListing: KDM, KDR, KDP andKFM, KCM, KCM-B and KCR.
Features and benefits:• Sizes and ratings available tomeet many applications.
Typical applications:• Protecting low voltage distribution and service entrancecables against short-circuit currents.
Catalog numbersCatalog Cable Catalog Cablenumber size number size
*Tubular terminalsKCY #4 KCF 4/0
KCZ #3 KCH 250kcmil
KCA #2 KCJ1, 2 350kcmil
KCB #1 KCM1, 2, 3 500kcmil
KCC 1/0 KCV 600kcmil
KCD1, 2 2/0 KCR1, 2 750kcmil
KCE 3/0 KCS 1000kcmil
*Tubular terminal and offset bolt-type terminalKQV #12 KDD 2/0
KQT #10 KDE 3/0
KFZ #8 KDF 4/0
KIG #6 KDH 250kcmil
KDY #4 KDJ3 350kcmil
KDA #2 KDM1,3 500kcmil
KDB #1 KDU 600kcmil
KDC 1/0 KDR1,2 750kcmil
*Compression connector rod and tubular terminalsKEX 4/0 KQO 350kcmil
KFH-A 250kcmil KDT 500kcmil
**Center bolt-type terminal and off-set bolt-type terminalKPF 4/0 KDP1 500kcmil
KFT 250kcmil KFM1 750kcmil
KEW 350kcmil*Copper conductors only.**Copper or aluminum conductors.1UL Listed (File E90818), 600Vac, 200k A I.R..2Available with shrink tube “_V” suffix.3Available with molded rubber boots. Boot can be purchased separately, order Part# - BOOT-KCM.
AccessoriesBoots can be purchased separately.
For KCM BOOT-KCM For KDM BOOT-KDM
Installation tools can be purchased separately from Thomas and Betts• Crimp Tool: TBM-14M • Die: 15506 KDM/15515 KDR
Specifications:Description: Welder limiters.Ratings:Volts — 600Vac (or less)IR — 200kA RMS Sym.
Features and benefits:• Current-limiting devices designed specially for useon welder circuits only
• Time-current characteristics are designed to holdon the intermittent overloading encountered inwelder operation, while providing short-circuit protection to the circuit and equipment
• Typical applications:• Welder circuits• Because welder limiters have special characteristics, they arenot intended for application on general-use circuits
Catalog numbersCatalog Fuse holder Nominalnumbers type amp rating68300 Class H 300
68600 Class H 600
64200 Class J 200
64300 Class J 300
Data Sheet: 1042 Data Sheet: 1045
64000 and 68000
Recommended fuse blocks for 68000 and 64000 limiters• See page 3-2
UH 250V
Specifications:Description: Cable limiters.Ratings:Volts — up to 250VacIR — 100kA RMS Sym.
Terminals:• Center bolt-to-offset bolt – copper or aluminum conductors.
Conductors:• Copper or aluminum conductors are permitted per the listedcable size. Select the catalog symbol for the system conductor size. See data sheet 1042 for dimensions.
Typical applications:• Designed specifically for use in residental applications.
Catalog numbers
Center bolt-type terminal and off-set bolt-type terminalCatalog Copper cable Aluminum cablenumber size size
UHA 2/0AWG 4/0AWG
UHJ-M 3/0AWG 250kcmil
UHJ-T 350kcmil 500kcmil
UHJ-W 600kcmil 800kcmil
KTK
Description:
Fast-acting supplemental fuse.
For superior protection, Eaton recommends upgrading to Bussmann series Low-PeakTM Class CC fuses. See data sheet # 1023.
Catalog symbol / color code:
• KTK - Black (600Vac maximum voltage)
Ratings:
Fuse amp range
600Vac UL CSA
1/10 to 30
100kA X X
Agency information:
• CE, RoHS compliant
• UL Listed, Std. 248-14, Guide JDYX, File E19180
• CSA Certified: C22.2 No. 248.14, Class 1422-01, File 53787, HRC-MISC
Catalog numbers (amps)
LE! 600Vac
FAST ACTAG FUSE
KTK-10
Interrupting rating Agency at rated voltage information
KTK-1/10
KTK-1/8
KTK-2/10
KTK-1/4
KTK-3/10
KTK-4/10
KTK-3/4
KTK-1
KTK-1-1/4
KTK-1-1/2
KTK-2
KTK-2-1/2
KTK-4
KTK-5
KTK-6
KTK-7
KTK-7-1/2
KTK-8
KTK-12
KTK-15
KTK-20
KTK-25
KTK-30
KTK-1/2 KTK-3 KTK-9
KTK-6/10 KTK-3-1/2 KTK-10
Low voltage, supplementary fuses
13/32" x 1 1/2" Fast-acting 3
BAF
Description:
Fast-acting, supplemental fuse.
For superior protection, Eaton recommends upgrading to Bussmann series Low-PeakTM Class CC fuses. See data sheet # 1023.
Catalog symbol — color code:
• BAF - Green (250Vac max 1/4 to 30A)
Ratings:
Interrupting rating Agency
at system voltage information
Fuse amp
250 125 range
Vac Vac UL CSA
1/4 to 1 35A 10kA X
1-1/2 to 2-1/2 100A 10kA X
3
100A 10kA X X
4 to 10 200A 10kA X X
12 to 15 750A 10kA X X
20 to 30 200A 10kA
Agency information:
• CE
• UL Listed, Std. 248-14, 250Vac (3 to 15A) Guide JDYX, File E19180
• CSA Certified, 250Vac (1/4 to 15A) Class 1422-01, File 53787
Catalog numbers (amps)
BAF-1/4 BAF-1-8/10 BAF-6 BAF-12
BAF-1/2 BAF-2 BAF-6-1/4 BAF-15
Features:
• Color coded green for 250Vac maximum voltage rating
• Fiber tube construction
• Nickel-plated brass endcaps.
Typical applications:
• General purpose circuits
• Lighting circuit protection
• Meter circuits
For superior electrical protection, Eaton recommends upgrading BAF fuse applications to Bussmann series Low-Peak LP-CC fuses See page 1-7.
Data Sheet: 2011 (0-30)
Features:
Color coded black for 600Vac voltage rating
• Fast-acting for resistive loads
• Melamine tube construction
• Nickel-plated bronze endcaps
Typical applications:
• Control circuits
• Lighting circuit protection
• Meter circuits
For superior electrical protection, Eaton recommends upgrading KTK fuse applications to Bussmann series Low-Peak LP-CC fuses See page 1-7.
Data Sheet: 1011
BAF-6/10 BAF-2-1/2 BAF-7 BAF-20
BAF-8/10 BAF-3 BAF-8 BAF-25
BAF-1
BAF-4
BAF-9
BAF-30
BAF-1-1/2 BAF-5
BAF-10
Recommended fuse blocks/fuse holders for 94 x 1 IC fuses • See page 3-2
BUSSMANN SERIES FULL LINE CATALOG 1007—July 2015 Eaton.corn/bussmannseries 3-5 3-5
Low voltage
supplementary
fuses
3Low voltage, supplementary fuses13/32˝ x 1 1/2˝ Fast-acting
BUSSMANN SERIES FULL LINE CATALOG 1007—July 2015 Eaton.com/bussmannseries
Recommended fuse blocks/fuse holders for 13⁄32˝ x 1 1⁄2˝ fuses• See page 3-2
Data Sheet: 1011Data Sheet: 2011 (0-30)
Description:
Fast-acting, supplemental fuse.
For superior protection, Eaton recommends upgrading to Bussmann series Low-Peak™ Class CC fuses. See data sheet # 1023.
Catalog symbol – color code:
• BAF - Green (250Vac max 1/4 to 30A)
Ratings:
Fuse amp range
Interrupting rating at system voltage
Agency information
250Vac
125Vac UL CSA
1/4 to 1 35A 10kA - X
1-1/2 to 2-1/2 100A 10kA - X
3 100A 10kA X X
4 to 10 200A 10kA X X
12 to 15 750A 10kA X X
20 to 30 200A 10kA - -
Agency information:• CE
• UL Listed, Std. 248-14, 250Vac (3 to 15A) Guide JDYX, File E19180
• CSA Certified, 250Vac (1/4 to 15A) Class 1422-01, File 53787
Catalog numbers (amps)
BAF-1⁄4 BAF-1-8⁄10 BAF-6 BAF-12
BAF-1⁄2 BAF-2 BAF-6-1⁄4 BAF-15
BAF-6⁄10 BAF-2-1⁄2 BAF-7 BAF-20
BAF-8⁄10 BAF-3 BAF-8 BAF-25
BAF-1 BAF-4 BAF-9 BAF-30
BAF-1-1⁄2 BAF-5 BAF-10
C
BAF
Description:
Fast-acting supplemental fuse.
For superior protection, Eaton recommends upgrading to Bussmann series Low-Peak™ Class CC fuses. See data sheet # 1023.
Catalog symbol / color code:
• KTK - Black (600Vac maximum voltage)
Ratings:
Fuse amp range
Interrupting rating at rated voltage
Agency information
600Vac UL CSA
1/10 to 30 100kA X X
Agency information:• CE, RoHS compliant
• UL Listed, Std. 248-14, Guide JDYX, File E19180
• CSA Certified: C22.2 No. 248.14, Class 1422-01, File 53787, HRC-MISC
Catalog numbers (amps)
KTK-1/10 KTK-3/4 KTK-4 KTK-12
KTK-1/8 KTK-1 KTK-5 KTK-15
KTK-2/10 KTK-1-1/4 KTK-6 KTK-20
KTK-1/4 KTK-1-1/2 KTK-7 KTK-25
KTK-3/10 KTK-2 KTK-7-1/2 KTK-30
KTK-4/10 KTK-2-1/2 KTK-8
KTK-1/2 KTK-3 KTK-9
KTK-6/10 KTK-3-1/2 KTK-10
Features:
• Color coded black for 600Vac voltage rating
• Fast-acting for resistive loads
• Melamine tube construction
• Nickel-plated bronze endcaps
Typical applications:
• Control circuits
• Lighting circuit protection
• Meter circuits
C
KTK
For superior electrical protection, Eaton recommends upgrading BAF fuseapplications to Bussmann series Low-Peak LP-CC fuses See page 1-7.
For superior electrical protection, Eaton recommends upgrading KTK fuseapplications to Bussmann series Low-Peak LP-CC fuses See page 1-7.
Features:
• Color coded green for 250Vac maximum voltage rating
• Fiber tube construction
• Nickel-plated brass endcaps.
Typical applications:
• General purpose circuits
• Lighting circuit protection
• Meter circuits
R
3 Low voltage, supplementary fuses
13/32" x 1 1/2" Fast-acting
KLM
Description:
Fast-acting supplemental fuse.
For superior protection, Eaton recommends upgrading to Bussmann series Low-PeakTM Class CC fuses. See data sheet # 1023.
For protecting DC photovoltaic systems, Eaton recommends using Bussmann series PVM 10x3Omm PV fuses. See data sheet # 10121.
Catalog symbol / color code:
• KLM - Black (600Vac/dc maximum voltage)
Ratings:
600V FAsi.Arric
RAE
KLM-I5
Interrupting rating Agency
Fuse at rated voltage information
amp 600 600 range Vac Vdc UL CSA
1/10 to 30 100kA 50kA X X
Electrical characteristics:
% of amp rating Opening time
110% 4 Hours minimum
135% AC Opens within 1 hour
Agency information:
• CE, RoHS compliant
• UL Listed: Std. 248-14, Guide JDYX, File E19180
• CSA Certified, C22.2 No. 248. 14, Class 1422-01, File 53787
Catalog numbers (amps)
KLM-1/10 KLM-1 KLM-5 KLM-15
KLM-118 KLM-1-1/4 KLM-6 KLM-20
KLM-2/10 KLM-1-1/2 KLM-7 KLM-25
KLM-V4 KLM-2 KLM-8 KLM-30
KLM-3/10 KLM-2-12 KLM-9
KLM-12 KLM-3 KLM-10
KLM-3/4 KLM-4 KLM-12
Features:
• Color coded for 600Vac/dc
• A full range DC supplemental fuse
• Melamine tube construction
• Nickel-plated brass endcaps.
Recommended fuse blocks/fuse holders for 952"x 1 W fuses • See page 3-2
Data Sheet: 2020
34 BUSSMANN SERIES FULL LINE CATALOG 1007—July 2015 Eaton.corn/bussmannseries 3-6 BUSSMANN SERIES FULL LINE CATALOG 1007—July 2015 Eaton.com/bussmannseries
3 Low voltage, supplementary fuses13/32˝ x 1 1/2˝ Fast-acting
Data Sheet: 2020
Description:
Fast-acting supplemental fuse.
For superior protection, Eaton recommends upgrading to Bussmann series Low-Peak™ Class CC fuses. See data sheet # 1023.
For protecting DC photovoltaic systems, Eaton recommends using Bussmann series PVM 10x30mm PV fuses. See data sheet # 10121.
Catalog symbol / color code:
• KLM - Black (600Vac/dc maximum voltage)
Ratings:
Fuse amp range
Interrupting rating at rated voltage
Agency information
600Vac
600Vdc UL CSA
1/10 to 30 100kA 50kA X X
Electrical characteristics:
% of amp rating Opening time
110% 4 Hours minimum
135% AC Opens within 1 hour
Agency information:
• CE, RoHS compliant
• UL Listed: Std. 248-14, Guide JDYX, File E19180
• CSA Certified, C22.2 No. 248. 14, Class 1422-01, File 53787
Catalog numbers (amps)
KLM-1⁄10 KLM-1 KLM-5 KLM-15
KLM-1⁄8 KLM-1-1⁄4 KLM-6 KLM-20
KLM-2⁄10 KLM-1-1⁄2 KLM-7 KLM-25
KLM-1⁄4 KLM-2 KLM-8 KLM-30
KLM-3⁄10 KLM-2-1⁄2 KLM-9
KLM-1⁄2 KLM-3 KLM-10
KLM-3⁄4 KLM-4 KLM-12
Features:
• Color coded for 600Vac/dc
• A full range DC supplemental fuse
• Melamine tube construction
• Nickel-plated brass endcaps.
T
KLM
Recommended fuse blocks/fuse holders for 13⁄32˝ x 1 1⁄2˝ fuses• See page 3-2
3
250Vac
yyl 10
4s
Low voltage, supplementary fuses
13/32" x 1 1/2" Time-delay
FNM
Description:
Time-delay supplemental fuse.
For superior protection, Eaton recommends upgrading to Bussmann series Low-PeakTM Class CC fuses. See data sheet # 1023.
Catalog symbol / color code:
• FNM - Green (250Vac maximum voltage)
Ratings:
Fuse amp range
Interrupting rating at system voltage
Agency information
250Vac 125Vac UL CSA
1/10 to 1 35A 10kA X X
1-1/8 to 3-1/2 100A 10kA X X
4 to 10 200A 10kA X X
12 to 30 10kA X X
Agency information:
• CE, RoHS complaint
• UL Listed, Std. 248-14, Guide JDYX; File E19180
• CSA Certified, Class 1422-01, File 53787
Catalog numbers (amps)
FNM-1/10 FNM-8/ 0 FNM-2-1/2 FNM-6-1/4
FNM-1i8 FNM-1 FNM-2-8/ 0 FNM-7
FNM-151 00 FNM-1-1i8 FNM-3 FNM-8
FNM-2/10 FNM-1-1/4 FNM-3-2/10 FNM-9
FNM-1/4 FNM-1-41 FNM-3-1/2 FNM-10
FNM-31 FNM-1-1/2 FNM-4 FNM-12
FNM-41 FNM-1-61 FNM-4-1/2 FNM-15
FNM-1/2
FNM-1-8/ 0 FNM-5 FNM-20
FNM-61 0
FNM-2 FNM-5-61 FNM-25
F N M-3/4 FNM-2-1/4 FNM-6 FNM-30
Features:
• Color coded green for 250Vac maximum voltage rating
• Melamine tube construction
• Nickel-plated brass endcaps
Typical applications:
• Circuits with high inrush currents (motor/transformer loads)
• Supplemental protection for 125Vac and 250Vac inductive circuits.
FNQ
Description:
Time-delay supplemental fuse.
For superior protection, Eaton recommends upgrading to Bussmann series FNQ-R Class CC fuses. See data sheet # 1014.
Catalog symbol / color code:
• FNQ - Orange (500Vac maximum voltage)
Interrupting rating Agency at rated voltage information
UL CSA
1/10 to 30 10kA
Agency information:
• CE, RoHS compliant*
• UL Listed, Std. 248-14, Guide JDYX, File E19180
• CSA Certified: C22.2 No. 248.14, Class 1422-01, File 53787, HRC-MISC RoHS
FNQ-1/8 not RoHS compliant.
Catalog numbers (amps)
FNQ-1/10
FNQ-8/10 FNQ-3-2/10 FNQ-9
FNQ-1/8
F NO-1
FNQ-3-1/2 FNQ-10
FNQ-15/100 FNQ-1-1/8 FNQ-4
FNQ-12
FNQ-3/16 FNQ-1-1/4 FNQ-4-1/2 FNQ-14
FNQ-2/10 FNQ-1-1/2 FNQ-5
FNQ-15
FNQ-1/4
FNQ-1-6/10 FNQ-5-6/10 FNQ-20
FNQ-3/10 FNQ-2 FNQ-6 FNQ-25
FNQ-4/10 FNQ-2-1/4 FNQ-6-1/4 FNQ-30
FNQ-1/2 FNQ-2-1/2 FNQ-7
FNQ-6/10 FNQ-3 FNQ-8
Features:
• Color coded for 500Vac maximum voltage rating
• Fiber tube construction
• Nickel-plated brass endcaps
Typical applications:
• Motor control transformers
• Circuits with in-rush currents.
Carton quantity
Amps Qty.
Ratings:
Fuse amp range 500Vac
For superior electrical protection, Eaton recommends upgrading FNM and FNQ fuse applications to Bussmann series Low-Peak LP-CC fuses See page 1-7.
Recommended fuse blocks and fuse holders for
152-x 1 1,4" fuses • See page 3-2
Data Sheet: 2028
1/10 to 30 10
For superior electrical protection, Eaton recommends upgrading FNM and FNQ fuse applications to Bussmann series Low-Peak LP-CC fuses See page 1-7.
Recommended fuse blocks and fuse holders for
1%2" x 1 1,4" fuses • See page 3-2
Data Sheet: 1012
BUSSMANN SERIES FULL LINE CATALOG 1007—July 2015 Eaton.corn/bussmannseries 3.7 3-7
Low voltage
supplementary
fuses
3Low voltage, supplementary fuses13/32˝ x 1 1/2˝ Time-delay
BUSSMANN SERIES FULL LINE CATALOG 1007—July 2015 Eaton.com/bussmannseries
Data Sheet: 2028 Data Sheet: 1012
For superior electrical protection, Eaton recommends upgrading FNM and FNQ fuse applications to Bussmann series Low-Peak LP-CC fuses See page 1-7.
Recommended fuse blocks and fuse holders for 13⁄32˝ x 1 1⁄2˝ fuses • See page 3-2
For superior electrical protection, Eaton recommends upgrading FNM and FNQ fuseapplications to Bussmann series Low-Peak LP-CC fuses See page 1-7.
Recommended fuse blocks and fuse holders for 13⁄32˝ x 1 1⁄2˝ fuses • See page 3-2
FNM FNQ
Description:
Time-delay supplemental fuse.
For superior protection, Eaton recommends upgrading to Bussmann series Low-Peak™ Class CC fuses. See data sheet # 1023.
Catalog symbol / color code:
• FNM - Green (250Vac maximum voltage)
Ratings:
Fuse amp range
Interrupting rating at system voltage
Agency information
250Vac 125Vac UL CSA
1/10 to 1 35A 10kA X X
1-1/8 to 3-1/2 100A 10kA X X
4 to 10 200A 10kA X X
12 to 30 10kA - X X
Agency information:
• CE, RoHS complaint
• UL Listed, Std. 248-14, Guide JDYX; File E19180
• CSA Certified, Class 1422-01, File 53787
Catalog numbers (amps)
FNM-1⁄10 FNM-8⁄10 FNM-2-1⁄2 FNM-6-1⁄4
FNM-1⁄8 FNM-1 FNM-2-8⁄10 FNM-7
FNM-15⁄100 FNM-1-1⁄8 FNM-3 FNM-8
FNM-2⁄10 FNM-1-1⁄4 FNM-3-2⁄10 FNM-9
FNM-1⁄4 FNM-1-4⁄10 FNM-3-1⁄2 FNM-10
FNM-3⁄10 FNM-1-1⁄2 FNM-4 FNM-12
FNM-4⁄10 FNM-1-6⁄10 FNM-4-1⁄2 FNM-15
FNM-1⁄2 FNM-1-8⁄10 FNM-5 FNM-20
FNM-6⁄10 FNM-2 FNM-5-6⁄10 FNM-25
FNM-3⁄4 FNM-2-1⁄4 FNM-6 FNM-30
Features:
• Color coded green for 250Vac maximum voltage rating
• Melamine tube construction
• Nickel-plated brass endcaps
Typical applications:
• Circuits with high inrush currents (motor/transformer loads)
• Supplemental protection for 125Vac and 250Vac inductive circuits.
C
Description:
Time-delay supplemental fuse.
For superior protection, Eaton recommends upgrading to Bussmann series FNQ-R Class CC fuses. See data sheet # 1014.
Catalog symbol / color code:
• FNQ - Orange (500Vac maximum voltage)
Ratings:
Fuse amp range
Interrupting rating at rated voltage
Agency information
500Vac UL CSA
1/10 to 30 10kA X X
Agency information:
• CE, RoHS compliant*
• UL Listed, Std. 248-14, Guide JDYX, File E19180
• CSA Certified: C22.2 No. 248.14, Class 1422-01, File 53787, HRC-MISC
* FNQ-1/8 not RoHS compliant.
Catalog numbers (amps)
FNQ-1/10 FNQ-8/10 FNQ-3-2/10 FNQ-9
FNQ-1/8 FNQ-1 FNQ-3-1/2 FNQ-10
FNQ-15/100 FNQ-1-1/8 FNQ-4 FNQ-12
FNQ-3/16 FNQ-1-1/4 FNQ-4-1/2 FNQ-14
FNQ-2/10 FNQ-1-1/2 FNQ-5 FNQ-15
FNQ-1/4 FNQ-1-6/10 FNQ-5-6/10 FNQ-20
FNQ-3/10 FNQ-2 FNQ-6 FNQ-25
FNQ-4/10 FNQ-2-1/4 FNQ-6-1/4 FNQ-30
FNQ-1/2 FNQ-2-1/2 FNQ-7
FNQ-6/10 FNQ-3 FNQ-8
Features:
• Color coded for 500Vac maximum voltage rating
• Fiber tube construction
• Nickel-plated brass endcaps
Typical applications:
• Motor control transformers
• Circuits with in-rush currents.
Carton quantity
Amps Qty.1/10 to 30 10
Low voltage, supplementary fuses 13/32" x 1 3/8" Fast-acting and pin indication
3 BBS
EMI 600Vac
600Vac 1/10 to 6A
250Vac
250Vac 7 to 10A
48Vac 12 to 30A
Description:
Fast-acting supplemental fuse.
For superior protection, Eaton recommends upgrading to Bussmann series Low-PeakTM Class CC fuses. See data sheet # 1023.
Catalog symbol / color code:
• BBS - Black (600Vac max voltage 1/10 to 6A) - Green (250Vac max voltage 7 to 10A) - Purple (48Vac max voltage 12 to 30A)
Ratings:
Fuse amp range
1/10 to 6 7 to 10
Interrupting rating at Agency system voltage information
600 250 48 Vac Vac Vac UL CSA
101<A
X
X
10I<A
X
X
12 to 30*
* For interrupting rating, contact factory.
Agency information:
• CE
• UL Listed, Std. 248-14 (1/10-6A©600Vac, 7-10A@250Vac), Guide JDYX, File E19180
• CSA Certified, C22.2 No. 248.14 (1/10-6A@600Vac, 7-10A@250Vac), Class 1422-01, File 53787
Catalog numbers (amps)
BBS-1/10 BBS-8/10 BBS-4 BBS-15
BBS-2/10 BBS-1 BBS-5 BBS-20
BBS-1/4 BBS-1-1/2 BBS-6 BBS-25
BBS-4/10 BBS-1-6/10 BBS-7 BBS-30 BBS-1/2 BBS-1-8/10 BBS-8
BBS-6/10 BBS-2 BBS-10
BBS-3/4 BBS-3 BBS-12
Features:
• Color coded for 600Vac (black) 250Vac (green) and 48Vac (purple) for maximum voltage ratings
• Fiber tube construction
• Nickel-plated brass endcaps.
Typical applications:
• Control circuits • Electronic circuits
• Gaseous vapor fixtures • Hand-held meters
• HID ballasts
GBA
GLD Specifications: Class: Supplemental
Description: Fast-acting, pin indication fuse.
Dimensions: 1/4""x 1 "A- (6.6 x 31.7mm) 3AG.
Ratings:
Volts — See Agency Info below
Amps — X-15A
IR — See Agency Info below
Agency information: CE, Std. 248-14, UL Listed, 0-5N125Vac, 10,000 AIC, Guide JDYX, File E19180, UL Recognized, 6N125Vac, 1000AIC 8-15A/50Vac/dc, 300 AIC Guide JDYX2, File E19180, CSA Certified: 0-5N125Vac, 10,000 AIC Class 1422-01, File 53787.
Features and benefits: • Type GBA has a "red" pin indicator providing
visual identification of failed circuits, resulting in faster troubleshooting (reduced circuit downtime).
• Type GLD has a plated pin to activate transmitting a electrical signal to indicate the location of opened circuits, resulting in reduced downtime.
Typical applications: • Control circuits • Electronic circuits
GLD catalog numbers (amps) GLD-1,4 GLD-2 GLD-6
GLD 3/
GLD-3 GLD-10
GLD-1
GLD-4 GLD-12
GLD-1-1,4
GLD-5 GLD-15
GBA catalog numbers (amps) GBA-1,4 GBA-2 GBA-8
GBA-3%
GBA-3 GBA-10
GBA-1
GBA-4 GBA-15
GBA-1-1,4 GBA-5
Recommended fuse blocks/fuse holders for Wx 1 %-indicating fuses • Page 3-3
Data Sheet: 2012
Recommended fuse blocks/fuse holders for 94 x 1 fuses • Page 3-3
Data Sheet: 2010 (0-30A)
34 BUSSMANN SERIES FULL LINE CATALOG 1007—July 2015 Eaton.cornibussmannseries 3-8 BUSSMANN SERIES FULL LINE CATALOG 1007—July 2015 Eaton.com/bussmannseries
3 Low voltage, supplementary fuses13/32˝ x 1 3/8˝ Fast-acting and pin indication
Data Sheet: 2010 (0-30A)
Recommended fuse blocks/fuse holders for 13⁄32˝ x 1 3⁄8˝ fuses• Page 3-3
BBS
Description:
Fast-acting supplemental fuse.
For superior protection, Eaton recommends upgrading to Bussmann series Low-Peak™ Class CC fuses. See data sheet # 1023.
Catalog symbol / color code:
• BBS - Black (600Vac max voltage 1/10 to 6A) - Green (250Vac max voltage 7 to 10A) - Purple (48Vac max voltage 12 to 30A)
Ratings:
Fuse amp range
Interrupting rating at system voltage
Agency information
600Vac
250Vac
48Vac UL CSA
1/10 to 6 10kA - - X X
7 to 10 - 10kA - X X
12 to 30* - - - - -
* For interrupting rating, contact factory.
Agency information:• CE
• UL Listed, Std. 248-14 (1/10-6A@600Vac, 7-10A@250Vac), Guide JDYX, File E19180
• CSA Certified, C22.2 No. 248.14(1/10-6A@600Vac, 7-10A@250Vac), Class 1422-01, File 53787
Catalog numbers (amps)
BBS-1/10 BBS-8/10 BBS-4 BBS-15
BBS-2/10 BBS-1 BBS-5 BBS-20
BBS-1/4 BBS-1-1/2 BBS-6 BBS-25
BBS-4/10 BBS-1-6/10 BBS-7 BBS-30
BBS-1/2 BBS-1-8/10 BBS-8
BBS-6/10 BBS-2 BBS-10
BBS-3/4 BBS-3 BBS-12
Features:
• Color coded for 600Vac (black) 250Vac (green) and 48Vac (purple) for maximum voltage ratings
• Fiber tube construction
• Nickel-plated brass endcaps.
Typical applications:
• Control circuits
• Gaseous vapor fixtures
• HID ballasts
C
600Vac1/10 to 6A
250Vac7 to 10A
48Vac12 to 30A
• Electronic circuits
• Hand-held meters
Specifications:Class: SupplementalDescription: Fast-acting, pin indicationfuse.Dimensions: 1⁄4˝ x 1 1⁄4˝ (6.6 x 31.7mm) 3AG.Ratings:Volts — See Agency Info belowAmps — 1⁄2-15A
IR — See Agency Info belowAgency information: CE,Std. 248-14, UL Listed, 0-5A/125Vac, 10,000 AIC,Guide JDYX, File E19180, UL Recognized,6A/125Vac, 1000AIC 8-15A/50Vac/dc, 300 AICGuide JDYX2, File E19180, CSA Certified: 0-5A/125Vac, 10,000 AIC Class 1422-01, File 53787.
Features and benefits:• Type GBA has a “red” pin indicator providing visual identification of failed circuits, resulting infaster troubleshooting (reduced circuit downtime).
• Type GLD has a plated pin to activate transmittinga electrical signal to indicate the location of openedcircuits, resulting in reduced downtime.
Typical applications:• Control circuits• Electronic circuits
GLD catalog numbers (amps)GLD-1⁄2 GLD-2 GLD-6
GLD-3⁄4 GLD-3 GLD-10
GLD-1 GLD-4 GLD-12
GLD-1-1⁄2 GLD-5 GLD-15
GBA catalog numbers (amps)GBA-1⁄2 GBA-2 GBA-8
GBA-3⁄4 GBA-3 GBA-10
GBA-1 GBA-4 GBA-15
GBA-1-1⁄2 GBA-5
Data Sheet: 2012
GBA
GLD
Recommended fuse blocks/fuse holders for 1⁄4˝ x 1 1⁄4˝
indicating fuses
• Page 3-3
3
250Vac
rm-2
AM&
250Vac 1/10 to 6A
'Ma* Ina
FNA-F2
, r -
Dual-tube construction 12A and up
32 Vac
250 Vac
35A
100A
200A
UL CSA
X
X
X
15 750A X
MIC
Description:
Fast-acting supplemental fuse.
Catalog symbol / color code:
• MIC - Green (250Vac max 1 to 15A) - Grey (32Vac max 20 to 30A)
250Vac 32Vac 1 to 15A
Ratings: 20 to 30A
Fuse amp range
1
2 to 3
5 to 10
Interrupting rating Agency at voltage rating information
250Vac
'Am
32Vac
FNA-1/10 FNA-1 FNA-3 FNA-9
FNA-1/8
F NA-15/100
FNA-2/10
FNA-1/4
FNA-3/10
FNA-4/10
FNA-1/2
FNA-1-1/8
FNA-1-1/4
FNA-1-4/10
FNA-1-1/2
FNA-1-6/10
FNA-1-8/10
FNA-2
FNA-3-2/10
FNA-3-1/2
FNA-4
FNA-4-1/2
FNA-5
FNA-5-6/10
FNA-6
FNA-10
FNA-12
F NA-15
FNA-20
FNA-25
FNA-30
FNA-6/10 FNA-2-1/4 FNA-6-1/4
FNA-3/4 FNA-2-1/2 FNA-7
FNA-8/10 FNA-2-8/10 FNA-8
Features:
Color coded by maximum voltage rating
• Pin indication for visual indication of open fuse condition
• Dual-element, time-delay performance permits close sizing on control transformers and relays
• Silver-plated pin for positive, electrical signal activation
• 12 amp and more versions are dual-tube construction
Recommended signal block for 'Yu" x 1 W indicating fuses • Page 3-3
Data Sheet: 2029
Low voltage, supplementary fuses
Pin indication
20 to 30 10kA
Electrical characteristics:
% of fuse rating Opening time
110% Indefinitely
135% 1 hour max.
Agency information:
• CE
• UL Listed, Std. 248-14, 1-15A, Guide JDYX, File E19180
Agency information:
• CE
• UL Listed 1/10 to 8/10A @ 125/250Vac, 1-15A @ 125Vac, Guide JDYX, File E19180
• CSA Certified 1/10 to 10A © 125Vac, Class 1422-01, File 53787
Catalog numbers (amps)
FNA Description:
Pin indicating time-delay supplemental fuse.
Catalog symbol / color code:
• FNA - Green (250Vac max voltage 1/10 to 6A) - Blue (125Vac max voltage 6-1/4 to 15A) - Grey (32Vac max voltage 20 to 30A)
Ratings:
Interrupting rating at Agency
Fuse system voltage information
amp
250 125 32 range Vac Vac Vac UL CSA
1/10 to
35A 10kA - X X 8/10
1 to 6 200A 10kA
6-1/4 to 15 - 101(A
20 to 30 - 11(A
Features:
Color coded by maximum voltage rating
Pin indication for visual indication of open fuse condition
Silver-plated pin for positive, electrical signal activation
Fiber tube construction
Nickel-plated bronze endcaps
Typical applications:
• Power electronic circuits in which fuse opening must be quickly apparent
• Control circuits
• PLC Circuits
Catalog numbers (amps)
MIC-1 MIC-8 MIC-25
MIC-2 MIC-10 MIC-30
MIC-3 MIC-15
MIC-5 MIC-20
Recommended signal block for, 'Yu" x 1 W indicating fuses • Page 3-3
Data Sheet: 10246
BUSSMANN SERIES FULL LINE CATALOG 1007—July 2015 Eaton.corn/bussmannseries 3-9 3-9
Low voltage
supplementary
fuses
3Low voltage, supplementary fusesPin indication
BUSSMANN SERIES FULL LINE CATALOG 1007—July 2015 Eaton.com/bussmannseries
Data Sheet: 2029Data Sheet: 10246
Recommended signal block for, 13⁄32˝ x 1 1⁄2˝ indicating fuses• Page 3-3
Recommended signal block for 13⁄32˝ x 1 1⁄2˝ indicating fuses • Page 3-3
MIC
Description:
Fast-acting supplemental fuse.
Catalog symbol / color code:
• MIC - Green (250Vac max 1 to 15A) - Grey (32Vac max 20 to 30A)
Ratings:
Fuse amp range
Interrupting rating at voltage rating
Agency information
250Vac
32Vac UL CSA
1 35A - X -
2 to 3 100A - X -
5 to 10 200A - X -
15 750A - X -
20 to 30 - 10kA - -
Electrical characteristics:
% of fuse rating Opening time110% Indefinitely
135% 1 hour max.
Agency information:• CE
• UL Listed, Std. 248-14, 1-15A, Guide JDYX, File E19180
Features:
• Color coded by maximum voltage rating
• Pin indication for visual indication of open fuse condition
• Silver-plated pin for positive, electrical signal activation
• Fiber tube construction
• Nickel-plated bronze endcaps
Typical applications:
• Power electronic circuits in which fuse opening must be quickly apparent
• Control circuits
• PLC Circuits
Catalog numbers (amps)
MIC-1 MIC-8 MIC-25
MIC-2 MIC-10 MIC-30
MIC-3 MIC-15 –
MIC-5 MIC-20 –
C
250Vac1 to 15A
32Vac20 to 30A
FNA
Description:
Pin indicating time-delay supplemental fuse.
Catalog symbol / color code:
• FNA - Green (250Vac max voltage 1/10 to 6A) - Blue (125Vac max voltage 6-1/4 to 15A) - Grey (32Vac max voltage 20 to 30A)
Ratings:
Fuseamprange
Interrupting rating at system voltage
Agency information
250Vac
125Vac
32Vac UL CSA
1/10 to 8/10
35A 10kA - X X
1 to 6 200A 10kA - X X
6-1/4 to 15 - 10kA - X X
20 to 30 - - 1kA - -
Agency information:
• CE
• UL Listed 1/10 to 8/10A @ 125/250Vac, 1-15A @ 125Vac, Guide JDYX, File E19180
• CSA Certified 1/10 to 10A @ 125Vac, Class 1422-01, File 53787
Catalog numbers (amps)
FNA-1/10 FNA-1 FNA-3 FNA-9
FNA-1/8 FNA-1-1/8 FNA-3-2/10 FNA-10
FNA-15/100 FNA-1-1/4 FNA-3-1/2 FNA-12
FNA-2/10 FNA-1-4/10 FNA-4 FNA-15
FNA-1/4 FNA-1-1/2 FNA-4-1/2 FNA-20
FNA-3/10 FNA-1-6/10 FNA-5 FNA-25
FNA-4/10 FNA-1-8/10 FNA-5-6/10 FNA-30
FNA-1/2 FNA-2 FNA-6
FNA-6/10 FNA-2-1/4 FNA-6-1/4
FNA-3/4 FNA-2-1/2 FNA-7
FNA-8/10 FNA-2-8/10 FNA-8
Features:
• Color coded by maximum voltage rating
• Pin indication for visual indication of open fuse condition
• Dual-element, time-delay performance permits close sizing on control transformers and relays
• Silver-plated pin for positive, electrical signal activation
• 12 amp and more versions are dual-tube construction
C
250Vac1/10 to 6A
Dual-tubeconstruction12A and up
3
3 Low voltage, supplementary fuses Pin indication fuse, actuator and limiters
ANN and ANL Limiters
Specifications: Description: Circuit limiters. ANN: Very fast-acting limiter.
ANL: Non-time-delay limiter.
Dimensions: Vx 3 3/6" (22.2 x 81.0mm).
Ratings:
ANN:
Volts — 125Vac — 80Vdc
Amps — 10-800A
IR — 2500A @ 125Vac — 2700A @ 80Vdc
ANL:
Volts — 80Vdc
Amps — 35-750A
IR — 2700A @ 80Vdc Agency information:
ANN: 35-400A @ 125Vac, IR=2500A and 500A @ 80Vdc, IR=2700A: UL Recognized Guide JFHR2, File E56412; CSA Certified Class 1422-30, File 53787, CE for 35-400A. ANL: UL Recognized, CSA Certified, 35-750A @ 80Vdc, IR = 2700A, Guide JFHR2, File E56412, Class 1422-30, File 53787, SAE J1171.
Features and benefits: • Fast-acting circuit protection (ANN). • Time-delay sizing for inductive circuits (ANL). • Window shows limiter status.
Typical applications: • Fork lifts, marine, aviation
ANN catalog numbers (amps) ANN-10
ANN-90
ANN-225
ANN-400
ANN-35
ANN-100
ANN-250
ANN-500
ANN-40
ANN-125
ANN-275
ANN-600
ANN-50
ANN-150
ANN-300
ANN-700
ANN-60
ANN-175
ANN-325
ANN-800
ANN-80
ANN-200
ANN-350
MIS
Specifications: Class: Supplemental Description: Non time-delay pin indication fuse. Dimensions: 13,42-x
(10.3 x 50.8mm).
Ratings:
Volts — 600Vac Amps — 1-12A
IR — 200kA
Features and benefits: • Type MIS has a pin
indicator providing visual identification of failed circuits, resulting in faster troubleshooting (reduced circuit downtime).
• Type MIS can be used in circuits rated 600V or less.
• Type MIS has an interrupting rating of 200kA.
Typical applications: • 480V control circuits • PLC circuits
Catalog numbers (amps) MIS-1
MIS-4
MIS-10
MIS-2
MIS-5
MIS-12
MIS-3
MIS-8
Test specifications Fuse Load Opening time All
110% 4 hrs. (min.)
1-5A 150% 6 min. (max.)
6-12A
150% 12 min. (max.)
Recommended signal block for 1%2" x 2" indicating fuses
• Page 3-3
Data Sheet: 2021
KAZ
Specifications: Description: Non-fuse actuator. Dimensions: 13,42-x
(10.3 x 50.8mm).
Ratings:
Volts — 600Vac Amps — N/A
IR — 200kA
Agency information: CE, UL Listed, Guide JDVS, File E58836.
Features and benefits: • Bussmann series signal
blocks 2778, 2837 or 2838 with KAZ actuators mounted in parallel with fuses having a rating of 50A or larger to provide blown fuse dropout of shunt-trip fused switches.
• Type KAZ can be used in circuits rated 600V or less.
• Type KAZ has an interrupting rating of 200kA.
Typical applications: • Large, shunt-trip fused switches • Fuse protected circuits rated 50A or
larger with shunt-trip devices.
Catalog number: KAZ
Recommended signal block for 1%2" x T indicating fuses
• Page 3-3
Data Sheet: 2021
4164 and 4164-FR limiter blocks ANL catalog numbers (amps) ANL-35
ANL-125 ANL-250 ANL-500
ANL-40
ANL-130 ANL-275 ANL-600 ANL-50
ANL-150 ANL-300 ANL-675
ANL-60
ANL-175 ANL-325 ANL-750
ANL-80
ANL-200 ANL-350
ANL-100
ANL-225 ANL-400
Data Sheets: 2023 (ANN), 2024 (ANL)
Specifications Description: Limiter fuse blocks for ANL and ANN.
• 4164 furnished with nylon inserted locknuts • 4164-FR furnished with standard hex nuts Dimensions: Length: 3.38"
Width: 0.95" Height: 1.62"
Studs center to center: 2.43"
Data Sheet: 2133
Ratings:
Volts — 125Vac
— 80Vdc
— 32Vdc (self certified)
Amps — 10-800A
Poles: 1 - stud terminal
3-10 BUSSMANN SERIES FULL LINE CATALOG 1007—July 2015 Eaton.com/bussmannseries 3-10 BUSSMANN SERIES FULL LINE CATALOG 1007—July 2015 Eaton.com/bussmannseries
3 Low voltage, supplementary fusesPin indication fuse, actuator and limiters
Data Sheet: 2133
ANN and ANL Limiters
Specifications:Description: Circuit limiters.ANN: Very fast-acting limiter.ANL: Non-time-delay limiter.Dimensions: 7⁄8˝ x 3 3⁄16˝ (22.2 x 81.0mm).Ratings:ANN:Volts — 125Vac
— 80VdcAmps — 10-800A
IR — 2500A @ 125Vac— 2700A @ 80Vdc
ANL:Volts — 80VdcAmps — 35-750A
IR — 2700A @ 80VdcAgency information:ANN: 35-400A @ 125Vac, IR=2500Aand 500A @ 80Vdc, IR=2700A: ULRecognized Guide JFHR2, File E56412;CSA Certified Class 1422-30, File53787, CE for 35-400A.ANL: UL Recognized, CSA Certified,35-750A @ 80Vdc, IR = 2700A, GuideJFHR2, File E56412, Class 1422-30,File 53787, SAE J1171.
Features and benefits:• Fast-acting circuit protection (ANN).• Time-delay sizing for inductive circuits (ANL).• Window shows limiter status.
Typical applications:• Fork lifts, marine, aviation
ANN catalog numbers (amps)ANN-10 ANN-90 ANN-225 ANN-400
ANN-35 ANN-100 ANN-250 ANN-500
ANN-40 ANN-125 ANN-275 ANN-600
ANN-50 ANN-150 ANN-300 ANN-700
ANN-60 ANN-175 ANN-325 ANN-800
ANN-80 ANN-200 ANN-350
ANL catalog numbers (amps)ANL-35 ANL-125 ANL-250 ANL-500
ANL-40 ANL-130 ANL-275 ANL-600
ANL-50 ANL-150 ANL-300 ANL-675
ANL-60 ANL-175 ANL-325 ANL-750
ANL-80 ANL-200 ANL-350
ANL-100 ANL-225 ANL-400
4164 and 4164-FR limiter blocks
SpecificationsDescription: Limiter fuse blocks for ANL and ANN.• 4164 furnished with nylon inserted locknuts• 4164-FR furnished with standard hex nutsDimensions: Length: 3.38˝
Width: 0.95˝Height: 1.62˝
Studs center to center: 2.43˝
Ratings:Volts — 125Vac
— 80Vdc— 32Vdc (self certified)
Amps — 10-800A
Poles: 1 - stud terminal
KAZ
Specifications:Description: Non-fuse actuator.Dimensions: 13⁄32˝ x 2˝ (10.3 x 50.8mm).
Ratings:Volts — 600VacAmps — N/A
IR — 200kAAgency information:CE, UL Listed, GuideJDVS, File E58836.
Features and benefits:• Bussmann series signalblocks 2778, 2837 or 2838 with KAZ actuators mounted in parallel with fuses having a rating of 50A or larger to provide blown fuse dropout of shunt-trip fused switches.
• Type KAZ can be used in circuits rated600V or less.
• Type KAZ has an interrupting rating of200kA.
Typical applications:• Large, shunt-trip fused switches• Fuse protected circuits rated 50A orlarger with shunt-trip devices.
Catalog number: KAZ
MIS
Specifications:Class: SupplementalDescription: Non time-delay pin indication fuse.Dimensions: 13⁄32˝ x 2˝(10.3 x 50.8mm).
Ratings:Volts — 600VacAmps — 1-12A
IR — 200kAFeatures and benefits:• Type MIS has a pin indicator providing visualidentification of failed circuits, resulting in faster troubleshooting (reducedcircuit downtime).
• Type MIS can be used in circuits rated600V or less.
• Type MIS has an interruptingrating of 200kA.
Typical applications:• 480V control circuits• PLC circuits
Catalog numbers (amps)MIS-1 MIS-4 MIS-10MIS-2 MIS-5 MIS-12MIS-3 MIS-8
Test specificationsFuse Load Opening timeAll 110% 4 hrs. (min.)
1-5A 150% 6 min. (max.)
6-12A 150% 12 min. (max.)
Data Sheet: 2021
Data Sheets: 2023 (ANN), 2024 (ANL)
Recommended signal block for13⁄32˝ x 2˝ indicating fuses
• Page 3-3
Recommended signal block for 13⁄32˝ x 2˝ indicating fuses
• Page 3-3
Data Sheet: 2021
Low voltage, supplementary fuses In-line size rejecting fuses and fuse holders
3 GLQ
Specifications: Class: Supplemental Description: Fast-acting, size-rejecting in-line fuse.
Construction: Glass tube. Ratings:
Volts — 300Vac (or less) Amps — 1-10A
IR — 10kA
Agency information: CE, UL Listed Std. 248-14, (Guide JDYX, File E19180), CSA Certified C22.2 No. 248.14, (Class 1422-01,File 53787).
Features and benefits: • In-line, fast-acting circuit protection. • Rejection feature prevents overfusing.
Typical applications: • In-line lighting ballast protection
Catalog numbers (amps) and rejection holders Fuse Holder'', 2
Fuse Holder'', 2
GLQ-1 HLQ-1-%
GLQ-3 HLQ-3-%
GLQ-1-1h HLQ-1-%
GLQ-4 HLQ-5
GLQ-1-% HLQ-1-%
GLQ-5 HLQ-5
GLQ-2 HLQ-3-%
GLQ-9 HLQ-10
GLQ-2 -16 HLQ-3
GLQ-10 HLQ-10
1) Carrier is UL Recognized, Guide IZLT2, File E14853 and CSA Certified, Class 6225-01, File 47235 10A, 300Vac.
2) Units can be panel-mounted either in a knockout hole with a separate steel clip (BK/A-104) or in a keyhole punch using separate mounting clip #6374 for panels of thickness 0.043"to 0.062" or #4909 for thickness 0.030" to 0.042".
• Do not put tension on line (rear) terminal of fuse holder.
Data Sheet: 2033
GMQ
Specifications: Class: Supplemental
Description: Time-delay, size-rejecting in-line fuse.
Construction: Ceramic tube.
Ratings:
Volts — 300Vac (or less)
Amps — IA-61/4A
IR — 10kA
Agency information: CE, UL Listed Std. 248-14, (Guide JDYX, File E19180), CSA Certified, (Class 1422-01, File 53787)
Features and benefits: • In-line, fast-acting circuit protection. • Rejection feature prevents overfusing.
Typical applications: • In-line lighting ballast protection
Catalog numbers (amps) and rejection holders Fuse Holders'', 2 Fuse Holders% 4 GMQ-1A HLQ-1A GMQ-2-1A HLQ-3-3So
GMQ- o HLQ-1-Vo GMQ-3 HLQ-3-350
GMQ -Yo HLQ-1-Vo GMQ-3 -Yo HLQ-3-3So
GMQ-1 HLQ-1-Vo GMQ-4 HLQ-5
GMQ-1-% HLQ-1-Vo GMQ-5 HLQ-5
GMQ-1-Vo HLQ-1-Vo GMQ-6-'''A HLQ-8
GMQ-2 HLQ-3
1) Carrier is UL Recognized, Guide IZLT2, File El 4853 and CSA Certified, Class 6225-01, File 47235 10A, 300Vac.
2) Units can be panel-mounted either in a knockout hole with a separate steel dip (BK/A-104) or in a keyhole punch using separate mounting dip #6374 for panels of thickness 0.043"to 0.062" or #4909 for thickness 0.030" to 0.042"
• Do not put tension on line (rear) terminal of fuse holder.
Data Sheet: 2030
H LQ3 fuse holders for both GLQ and GMQ fuses.
BUSSMANN SERIES FULL LINE CATALOG 1007—July 2015 Eaton.corn/bussmannseries 3.11
GMQ
Specifications:Class: Supplemental
Description: Time-delay,size-rejecting in-line fuse.Construction: Ceramic tube.Ratings:Volts — 300Vac (or less)Amps — 1⁄2-61⁄4A
IR — 10kAAgency information: CE, UL Listed Std. 248-14, (GuideJDYX, File E19180), CSA Certified, (Class 1422-01, File 53787)
Features and benefits:• In-line, fast-acting circuit protection.• Rejection feature prevents overfusing.
Typical applications:• In-line lighting ballast protection
Catalog numbers (amps) and rejection holdersFuse Holders1, 2 Fuse Holders3, 4
GMQ-1⁄2 HLQ-1⁄2 GMQ-2-1⁄2 HLQ-3-2⁄10
GMQ-6⁄10 HLQ-1-6⁄10 GMQ-3 HLQ-3-2⁄10
GMQ-8⁄10 HLQ-1-6⁄10 GMQ-3-2⁄10 HLQ-3-2⁄10
GMQ-1 HLQ-1-6⁄10 GMQ-4 HLQ-5
GMQ-1-1⁄4 HLQ-1-6⁄10 GMQ-5 HLQ-5
GMQ-1-6⁄10 HLQ-1-6⁄10 GMQ-6-1⁄4 HLQ-8
GMQ-2 HLQ-3-2⁄101) Carrier is UL Recognized, Guide IZLT2, File E14853 and CSA Certified, Class 6225-01, File 47235
10A, 300Vac.2) Units can be panel-mounted either in a knockout hole with a separate steel clip (BK/A-104) or in a
keyhole punch using separate mounting clip #6374 for panels of thickness 0.043”to 0.062” or #4909for thickness 0.030” to 0.042”
• Do not put tension on line (rear) terminal of fuse holder.
3-11
3Low voltage, supplementary fusesIn-line size rejecting fuses and fuse holders
BUSSMANN SERIES FULL LINE CATALOG 1007—July 2015 Eaton.com/bussmannseries
Data Sheet: 2030Data Sheet: 2033
HLQ3 fuse holders
for both GLQ and GMQ fuses.
GLQ
Specifications:Class: SupplementalDescription: Fast-acting,size-rejecting in-line fuse.Construction: Glass tube.Ratings:Volts — 300Vac (or less)Amps — 1-10A
IR — 10kAAgency information: CE, UL Listed Std. 248-14, (GuideJDYX, File E19180), CSA Certified C22.2 No. 248.14, (Class 1422-01,File 53787).
Features and benefits:• In-line, fast-acting circuit protection.• Rejection feature prevents overfusing.
Typical applications:• In-line lighting ballast protection
Catalog numbers (amps) and rejection holdersFuse Holder1, 2 Fuse Holder1, 2
GLQ-1 HLQ-1-6⁄10 GLQ-3 HLQ-3-2⁄10GLQ-1-1⁄2 HLQ-1-6⁄10 GLQ-4 HLQ-5GLQ-1-6⁄10 HLQ-1-6⁄10 GLQ-5 HLQ-5GLQ-2 HLQ-3-2⁄10 GLQ-9 HLQ-10GLQ-2-1⁄2 HLQ-3 -2⁄10 GLQ-10 HLQ-10
1) Carrier is UL Recognized, Guide IZLT2, File E14853 and CSA Certified, Class 6225-01, File 4723510A, 300Vac.
2) Units can be panel-mounted either in a knockout hole with a separate steel clip (BK/A-104) or in akeyhole punch using separate mounting clip #6374 for panels of thickness 0.043”to 0.062” or #4909for thickness 0.030” to 0.042”.
• Do not put tension on line (rear) terminal of fuse holder.
Low voltage
supplementary
fuses
3 Low voltage, supplementary fuses In-line non-rejecting fuses and fuse holders
GLR
Specifications: Class: Supplemental
Description: Fast-acting, non-rejection, in-line fuse.
Construction: Glass tube.
Ratings:
Volts — 300Vac (or less)
Amps — 346-15A
IR — 10kA
Agency information: CE, UL Listed Std. 248-14, 0-15A/300Vac (Guide JDYX, File E19180), CSA Certified C22.2, No. 248-14, 0-10A/300V (Class 1422-01, File 53787).
Features and benefits: • In-line, fast-acting circuit protection.
Typical applications: • In-line lighting ballast protection
Catalog numbers (amps) and non-rejection holders Fuse Holder'', 2* Fuse Holder'', 2* GLR-1 HLR GLR-6 HLR GLR-1 HLR GLR-7 HLR GLR-1-1h HLR GLR-8 HLR GLR-1 -13Ao HLR GLR-9 HLR GLR-2 HLR GLR-10 HLR GLR-3 HLR GLR-12 HLR GLR-4 HLR GLR-15 HLR-2A GLR-5 HLR
1) Carrier is UL Recognized, Guide IZLT2, File E14853 and CSA Certified, Class 6225-01, File 47235 12A, 300Vac.
2) Units can be panel-mounted either in a knockout hole with a separate steel clip (BK/A-104) or in a keyhole punch using separate mounting clip #6374 for panels of thickness 0.043"to 0.062" or #4909 for thickness 0.030" to 0.042".
• For two leads (one each for line and loadside) order HLR-2A, 15A, 300V
• An alternative to the HLR fuse holder is the A fuse holder. The A fuse holder comes WITHOUT leads. The customer inserts #18 insulated solid copper wire into the line side receptacle as well as into the load side receptacle. It has the same body dimensions, utilizes the same mounting hole, and takes the same mounting clips as the HLR. The A fuse holder is UL Recognized, 10A, 300Vac, Guide IZLT2, File E14853 and CSA Certified, 10A, 300Vac, Class 6225-01, File 47235.
• Do not put tension on line (rear) terminal of fuse holder.
Data Sheet: 2032
GMF
GRF
Specifications: Class: Supplemental
Description: Time-delay, non-rejection, in-line fuse.
Construction: Glass tube.
Ratings:
Volts — 300Vac (or less)
Amps — 3/0-10A
IR — 10kA
Agency information: CE, UL Listed Std. 248-14 0-10A, (Guide JDYX, File E19180), CSA Certified, (Class 1422-01, File 53787).
Features and benefits: • In-line, time-delay circuits protection.
Typical applications: • In-line lighting ballast protection
Catalog numbers (amps) and non-rejection holders Fuse Holder'', 2* Fuse Holder'', 2* GMF-3A0 HLR GMF-3 HLR GMF-1 HLR GMF-3-2Ao HLR GMF-°Ao HLR GMF-4 HLR GMF-8A0 HLR GMF-5 HLR GMF-1 HLR GMF-6-14 HLR GMF-1 '/a HLR GMF-7 HLR GMF-1 -% HLR GRF-8 HLR GMF-2 HLR GMF-10 HLR GMF-2-1/6 HLR GRF-10 HLR GMF-2-8Ao HLR
1) Carrier is UL Recognized, Guide IZLT2, File E14853 and CSA Certified, Class 6225-01, File 47235 12A, 300Vac.
2) Units can be panel-mounted either in a knockout hole with a separate steel clip (8K/A-104) or in a keyhole punch using separate mounting clip #6374 for panels of thickness 0.043"to 0.062" or #4909 for thickness 0.030" to 0.047.
*For two leads order HLR-2A, 15A, 300V
• An alternative to the HLR fuse holder is the A fuse holder. The A fuse holder comes WITHOUT leads. The customer inserts #18 insulated solid copper wire into the line side receptacle as well as into the load side receptacle. It has the same body dimensions, utilizes the same mounting hole, and takes the same mounting clips as the HLR. The A fuse holder is UL Recognized, 10A, 300Vac, Guide IZLT2, File 814853 and CSA Certified, 10A, 300Vac, Class 6225-01, File 47235.
• Do not put tension on line (rear) terminal of fuse holder.
Data Sheet: 2031
HLR-2A fuse holder HLR fuse holder
3-12 BUSSMANN SERIES FULL LINE CATALOG 1007—July 2015 Eaton.corn/bussmannseries 3-12 BUSSMANN SERIES FULL LINE CATALOG 1007—July 2015 Eaton.com/bussmannseries
3 Low voltage, supplementary fusesIn-line non-rejecting fuses and fuse holders
GLR
Specifications:Class: SupplementalDescription: Fast-acting,non-rejection, in-line fuse.Construction: Glass tube.Ratings:Volts — 300Vac (or less)Amps — 3⁄16-15A
IR — 10kAAgency information: CE, UL Listed Std. 248-14, 0-15A/300Vac (Guide JDYX, File E19180), CSA CertifiedC22.2, No. 248-14, 0-10A/300V (Class 1422-01, File 53787).
Features and benefits:• In-line, fast-acting circuit protection.
Typical applications:• In-line lighting ballast protection
Catalog numbers (amps) and non-rejection holdersFuse Holder1, 2* Fuse Holder1, 2*
GLR-1⁄2 HLR GLR-6 HLRGLR-1 HLR GLR-7 HLRGLR-1-1⁄2 HLR GLR-8 HLRGLR-1-6⁄10 HLR GLR-9 HLRGLR-2 HLR GLR-10 HLRGLR-3 HLR GLR-12 HLRGLR-4 HLR GLR-15 HLR-2AGLR-5 HLR
1) Carrier is UL Recognized, Guide IZLT2, File E14853 and CSA Certified, Class 6225-01,File 47235 12A, 300Vac.
2) Units can be panel-mounted either in a knockout hole with a separate steel clip (BK/A-104) or in a keyhole punch using separate mounting clip #6374 for panels ofthickness 0.043”to 0.062” or #4909 for thickness 0.030˝ to 0.042˝.
* For two leads (one each for line and loadside) order HLR-2A,15A, 300V
• An alternative to the HLR fuse holder is the A fuse holder. The A fuse holder comesWITHOUT leads. The customer inserts #18 insulated solid copper wire into the line sidereceptacle as well as into the load side receptacle. It has the same body dimensions,utilizes the same mounting hole, and takes the same mounting clips as the HLR. The Afuse holder is UL Recognized, 10A, 300Vac, Guide IZLT2, File E14853 and CSACertified, 10A, 300Vac, Class 6225-01, File 47235.
• Do not put tension on line (rear) terminal of fuse holder.
GMF
GRF
Specifications:Class: SupplementalDescription: Time-delay, non-rejection, in-line fuse.Construction: Glass tube.Ratings:Volts — 300Vac (or less)Amps — 3⁄10-10A
IR — 10kAAgency information: CE, UL Listed Std. 248-14 0-10A,(Guide JDYX, File E19180), CSA Certified, (Class 1422-01, File53787).
Features and benefits:• In-line, time-delay circuits protection.
Typical applications:• In-line lighting ballast protection
Catalog numbers (amps) and non-rejection holdersFuse Holder1, 2* Fuse Holder1, 2*
GMF-3⁄10 HLR GMF-3 HLRGMF-1⁄2 HLR GMF-3-2⁄10 HLRGMF-6⁄10 HLR GMF-4 HLRGMF-8⁄10 HLR GMF-5 HLRGMF-1 HLR GMF-6-1⁄4 HLRGMF-1-1⁄4 HLR GMF-7 HLRGMF-1-6⁄10 HLR GRF-8 HLRGMF-2 HLR GMF-10 HLRGMF-2-1⁄2 HLR GRF-10 HLRGMF-2-8⁄10 HLR
1) Carrier is UL Recognized, Guide IZLT2, File E14853 and CSA Certified, Class 6225-01, File 4723512A, 300Vac.
2) Units can be panel-mounted either in a knockout hole with a separate steel clip (BK/A-104) or in akeyhole punch using separate mounting clip #6374 for panels of thickness 0.043”to 0.062” or #4909for thickness 0.030˝ to 0.042˝.
*For two leads order HLR-2A, 15A, 300V
• An alternative to the HLR fuse holder is the A fuse holder. The A fuse holder comes WITHOUT leads.The customer inserts #18 insulated solid copper wire into the line side receptacle as well as into theload side receptacle. It has the same body dimensions, utilizes the same mounting hole, and takesthe same mounting clips as the HLR. The A fuse holder is UL Recognized, 10A, 300Vac, GuideIZLT2, File E14853 and CSA Certified, 10A, 300Vac, Class 6225-01, File 47235.
• Do not put tension on line (rear) terminal of fuse holder.
Data Sheet: 2032 Data Sheet: 2031
HLR fuse holderHLR-2A fuse holder
Available with
indication
LED indicator
Low voltage, supplementary fuses Automotive blade-type fuses and holders
3 ATC fuse
(actual size)
Specifications: Description: Fast-acting blade fuse.
Construction: Colored plastic housing with zinc fuse element.
Ratings:
Volts — 32Vdc
Amps — 1-40A
IR — 1000A
Agency information: UL Recognized, (1-40A) (Guide JFHR2, File E56412), SAE Standard J1284.
Features and benefits: • Color coded plastic housing for
easy identification of fuse ratings Typical applications: • Automotive
Catalog numbers (amps)
Non-indicating *Indicating Color
ATC-1
Black
ATC-2
ATC-3
ATC-31D
ATC-4
ATC-5
ATC-5ID
ATC-7-1/2 ATC-7-1/21D Brown
ATC-1 0 ATC-101D Red
ATC-15 ATC-151D Blue
ATC-20 ATC-201D Yellow
ATC-25 ATC-251D Clear
ATC-30 ATC-301D Green
ATC-35
ATC-351D Blue-Green
ATC-40 ATC-401D
Orange
*Call Eaton customer satisfaction for ordering information.
Data Sheet: 2009
HHA, HHC, HHD, HHF, HHG, HHR, HHS and ATC-FHID
easylDTM' LED indicating holder
Specifications:
Description: In-line fuse holders for ATC- blade-type fuses.
Dimensions: See dimensions illustration.
Ratings:
Volts: — 32Vdc
Amps: — 80% continuous of fuse rating. See catalog numbers table for individual fuses sizes.
Catalog numbers Catalog Fuse holder
Fuse Electrical
numbers description amps connection
1-40 #16 red leadwire
1-20 #16 black leadwire
1-30 #12 yellow leadwire
1-20 #16 yellow leadwire
1-30 #12 yellow leadwire
1-30 #12 red leadwire
1-20 #18 to 14 black leadwire
1-20 #16 black leadwire
A fuse must be properly and fully inserted into the holder to provide a solid connection. Poor or improper insertion of the fuse can result in failure of the fuse and holder, thus not protecting the device for which it was intended.
HHC and HHD dimensions - in
Data Sheet: 2107
ATM fuse
Available with
indication
(actual size) ATM
ATM-LP
Specifications: Description: Fast-acting blade fuse.
Construction: Colored plastic housing with zinc fuse element.
Ratings:
Volts — 32Vdc
Amps — 1-30A
IR — 1000A
Agency information: UL Listed Guide FHXT, File AU 169 (2-30A non-indicating ATM).
Features and benefits: • Color coded plastic housing for easy
identification of fuse ratings Typical applications: • Automotive
Catalog numbers (amps)
Non-indicating *Indicating Low-profile Color
ATM-1
ATM-2
ATM-3
ATM-31D
ATM-4
ATM-5
ATM-5ID
ATM-5LP
ATM-7-'/
ATM-7-'/ID
ATM-7-'/LP
ATM-10
ATM-101D
ATM-10LP
ATM-15
ATM-15ID
ATM-15LP
ATM-20
ATM-201D
ATM-20LP
ATM-25
ATM-251D
ATM-25LP
ATM-30
ATM-301D
ATM-30LP
*Call Eaton customer satisfaction for ordering information.
Data Sheet: 2048 (ATM), 2050 (ATM-LP)
Gray
Violet
Pink
Tan
ATC-FHID
HHA
HHC
HHD
HHF
HHG
HHR
HHS
Black w/ cover
Yellow
Black
Black w/ cover
Black w/ cover
Black w/ cover
Blue w/ cover
Indicating holder Black w/ cover
Black
Gray
Violet
Pink
Tan
Brown
Red
Blue
Yellow
Clear
Green
BUSSMANN SERIES FULL LINE CATALOG 1007—July 2015 Eaton.corn/bussmannseries 3-13 3-13
Low voltage
supplementary
fuses
3Low voltage, supplementary fusesAutomotive blade-type fuses and holders
BUSSMANN SERIES FULL LINE CATALOG 1007—July 2015 Eaton.com/bussmannseries
Specifications:Description: Fast-acting blade fuse.Construction: Colored plastichousing with zinc fuse element.Ratings:Volts — 32VdcAmps — 1-40A
IR — 1000AAgency information: ULRecognized, (1-40A) (GuideJFHR2, File E56412), SAE StandardJ1284.
Features and benefits:• Color coded plastic housing foreasy identification of fuse ratings
Typical applications:• Automotive
Catalog numbers (amps)
Data Sheet: 2048 (ATM), 2050 (ATM-LP)Data Sheet: 2009
(actual size)
ATC fuse ATM fuse
Specifications:Description: Fast-acting blade fuse.Construction: Colored plastic housingwith zinc fuse element.Ratings:Volts — 32VdcAmps — 1-30A
IR — 1000AAgency information: UL Listed GuideFHXT, File AU 169 (2-30A non-indicatingATM).
Features and benefits:• Color coded plastic housing for easyidentification of fuse ratings
Typical applications:• Automotive
Catalog numbers (amps)
ATM(actual size)
ATM-LP
Non-indicating *Indicating Color
ATC-1 — Black
ATC-2 — Gray
ATC-3 ATC-3ID Violet
ATC-4 — Pink
ATC-5 ATC-5ID Tan
ATC-7-1/2 ATC-7-1/2ID Brown
ATC-10 ATC-10ID Red
ATC-15 ATC-15ID Blue
ATC-20 ATC-20ID Yellow
ATC-25 ATC-25ID Clear
ATC-30 ATC-30ID Green
ATC-35 ATC-35ID Blue-Green
ATC-40 ATC-40ID Orange
Availablewith
indication
Availablewith
indication
Non-indicating *Indicating Low-profile Color
ATM-1 — — Black
ATM-2 — — Gray
ATM-3 ATM-3ID — Violet
ATM-4 — — Pink
ATM-5 ATM-5ID ATM-5LP Tan
ATM-7-1/2 ATM-7-1/2ID ATM-7-1/2LP Brown
ATM-10 ATM-10ID ATM-10LP Red
ATM-15 ATM-15ID ATM-15LP Blue
ATM-20 ATM-20ID ATM-20LP Yellow
ATM-25 ATM-25ID ATM-25LP Clear
ATM-30 ATM-30ID ATM-30LP Green0.78"
0.91"0.5"
0.38" 0.30"
4.0" + 0.25" 4.0" + 0.25"1.125"
0.364"
0.25"
Data Sheet: 2107
Specifications:Description: In-line fuse holders forATC™ blade-type fuses.Dimensions: See dimensionsillustration.Ratings:Volts: — 32VdcAmps:— 80% continuous of fuse
rating. See catalog numberstable for individual fuses sizes.
Catalog numbersCatalog Fuse holder Fuse Electricalnumbers description amps connection
HHA Black w/ cover 1-40 #16 red leadwire
HHC Yellow 1-20 #16 black leadwire
HHD Black 1-30 #12 yellow leadwire
HHF Black w/ cover 1-20 #16 yellow leadwire
HHG Black w/ cover 1-30 #12 yellow leadwire
HHR Black w/ cover 1-30 #12 red leadwire
HHS Blue w/ cover 1-20 #18 to 14 black leadwire
ATC-FHIDIndicating holder
1-20 #16 black leadwireBlack w/ cover
A fuse must be properly and fully inserted into the holder toprovide a solid connection. Poor or improper insertion of thefuse can result in failure of the fuse and holder, thus notprotecting the device for which it was intended.
HHC and HHD dimensions - in
HHA, HHC, HHD, HHF,HHG, HHR, HHS and ATC-FHID
easy ID™ LED indicating holder
LED indicator
*Call Eaton customer satisfaction for ordering information.
*Call Eaton customer satisfaction for ordering information.
LED indicator
Available with
indication
3 Low voltage, supplementary fuses Automotive blade-type fuses and holders
HHH, HHL, HHLP, HHM and ATM-FHID
easylDTM' LED indicating holder
Specifications:
Description: In-line fuse holders for ATM Fuses.
Ratings:
Volts: — 32Vdc
Amps: — 80% continuous of fuse rating. See catalog numbers table for individual fuses sizes.
Catalog numbers Catalog Fuse holder Fuse Electrical numbers description amps connection HHH Black w/ cover 1-30 #16 black le-edwire,
5- length
HHL Black w/ cover 1-20 #16 black leadwire, 4" length stripped to '/,,-
HHLP Black w/ cover 1-30 #16 black le-edwire,
5- length
HHM Black w/ cover 1-30 #12 red leadwire, 4" length stripped to 1/4-
HHU Black w/ cover 1-30 #16 black le-edwire,
Indicating holder ATM-FHID
1-20 #16 black le-edwire Black w/ cover
A fuse must be properly and fully inserted into the holder to provide a solid connection. Poor or improper insertion of the fuse can result in failure of the fuse and holder, thus not protecting the device for which it was intended.
HHL and HHM dimensions - in
156"
MAX Maxi-fuse
(actual size)
Specifications: Description: Fast-acting blade fuse.
Construction: Colored plastic housing with zinc fuse element.
Ratings:
Volts — 32Vdc
Amps — 20-80A (non-indicating) 20-100A (indicating)
IR — 1000A
Features and benefits: • Color coded plastic housing for easy
identification of fuse ratings Typical applications: • Automotive
Catalog numbers (amps)
Non-indicating *Indicating Color
MAX-20 MAX-201D Yellow
MAX-25 — Gray
MAX-30 MAX-301D Green
MAX-35 — Brown
MAX-40 MAX-401D Orange
MAX-50 MAX-501D Red
MAX-60 MAX-601D Blue
MAX-70 MAX-701D Tan
MAX-80 MAX-801D Clear
— MAX-1001D Purple
*Cal I Eaton customer satisfaction for ordering information.
HHX, MAX-FHID
Specifications:
Description: In-line fuse holders for MAXI Fuses.
Ratings:
Volts: — 32Vdc
Amps: — 80% continuous of fuse rating. See catalog numbers table for individual fuses sizes.
Catalog numbers Catalog Fuse holder Fuse Electrical numbers description amps connection HHX Black w/ cover 20-60 #6 red leadwire,
5 with blunt ends MAX-FHID Indicator black 20-60 #6 red leadwire,
w/ cover 5-with blunt ends
A fuse must be properly and fully inserted into the holder to provide a solid connection. Poor or improper insertion of the fuse can result in failure of the fuse and holder, thus not protecting the device for which it was intended.
Dimensions - in
s.s5"
0— J 6 70" 6 7014
1.37"
265" DIA. HOLE
(le ED III—,
// 25.
4.75"
4.75
Data Sheet: 2128
Recommended in-line fuse holder for
blade type fuses
• Page 3-15 Data Sheet: 2129
3-14 BUSSMANN SERIES FULL LINE CATALOG 1007—July 2015 Eaton.corn/bussmannseries 3-14
Data Sheet: 2129Data Sheet: 2128
Specifications:Description: In-line fuse holders forATM Fuses.Ratings:Volts: — 32VdcAmps: — 80% continuous of fuse
rating. See catalog numberstable for individual fuses sizes.
Catalog numbersCatalog Fuse holder Fuse Electricalnumbers description amps connectionHHH Black w/ cover 1-30 #16 black leadwire,
5˝ length
HHL Black w/ cover 1-20 #16 black leadwire,
4˝ length stripped to 1/4˝
HHLP Black w/ cover 1-30 #16 black leadwire,
5˝ length
HHM Black w/ cover 1-30 #12 red leadwire,
4˝ length stripped to 1/4˝
HHU Black w/ cover 1-30 #16 black leadwire,
ATM-FHIDIndicating holder
1-20 #16 black leadwireBlack w/ cover
A fuse must be properly and fully inserted into the holder toprovide a solid connection. Poor or improper insertion of thefuse can result in failure of the fuse and holder, thus notprotecting the device for which it was intended.
HHL and HHM dimensions - in
Specifications:Description: In-line fuse holders forMAXI Fuses.Ratings:Volts: — 32VdcAmps: — 80% continuous of fuse
rating. See catalog numberstable for individual fuses sizes.
Catalog numbersCatalog Fuse holder Fuse Electricalnumbers description amps connectionHHX Black w/ cover 20-60 #6 red leadwire,
5˝ with blunt ends
MAX-FHID Indicator black 20-60 #6 red leadwire,
w/ cover 5˝ with blunt ends
A fuse must be properly and fully inserted into the holder toprovide a solid connection. Poor or improper insertion of thefuse can result in failure of the fuse and holder, thus notprotecting the device for which it was intended.
Dimensions - in
HHX, MAX-FHIDHHH, HHL, HHLP, HHMand ATM-FHID
1.56"
4.75" 4.75" .25" .25"
.59"
.41"
3.35"
6.70" 6.70"
1.37"
.265" DIA. HOLE
easy ID™ LED indicating holder
LED indicator(actual size)
MAX Maxi–fuse
Specifications:Description: Fast-acting blade fuse.Construction: Colored plastic housingwith zinc fuse element.Ratings:Volts — 32VdcAmps — 20-80A (non-indicating)
20-100A (indicating)IR — 1000A
Features and benefits:• Color coded plastic housing for easy identification of fuse ratings
Typical applications:• Automotive
Catalog numbers (amps)
Recommended in-line fuse holder for
blade type fuses
• Page 3-15
Availablewith
indication
Non-indicating *Indicating Color
MAX-20 MAX-20ID Yellow
MAX-25 — Gray
MAX-30 MAX-30ID Green
MAX-35 — Brown
MAX-40 MAX-40ID Orange
MAX-50 MAX-50ID Red
MAX-60 MAX-60ID Blue
MAX-70 MAX-70ID Tan
MAX-80 MAX-80ID Clear
— MAX-100ID Purple
BUSSMANN SERIES FULL LINE CATALOG 1007—July 2015 Eaton.com/bussmannseries
3 Low voltage, supplementary fusesAutomotive blade-type fuses and holders
*Call Eaton customer satisfaction for ordering information.
T-
FUSECLIPS
8.64 0.340
, 7 0.144
I
1.65 .0.05 0.065 .0.002 DIA. HOLE (TYP-4)
MOUNTING LAYOUT
r 3.66 4.47 3.66 0.1767 0.144 7
ATR-25
ATR-30
Clear
Green
DIA. HOLE 2.54 .0.05 0.100 .0.002
(TYP-4)
MOUNTING LAYOUT
4.06 0.160
Low voltage, supplementary fuses Automotive blade-type fuses and PCB fuseclips
3 ATR micro fuse
Specifications: Description: Fast-acting color coded 2-leg micro blade fuse.
Construction: Colored plastic housing with zinc fuse element. Ratings:
Volts - 32Vdc
Amps - 5-30A IR - 1000A
Features and benefits: • Space-savings size • Industry standard color coding for
easy identification of fuse ratings Typical applications: • Automotive
Catalog numbers - (amps)
Catalog numbers Color ATR-5 Tan
ATR-7-1/2 Brown
ATR-10 Red
ATR-15 Blue
ATR-20 Yellow
ATC fuses (0 to 20 amps) 1A5600
Dimensional data
Catalog Clip Number Mat* Finish
1A5600 Cart. Satin Brass Finish Tin
Data Sheet: 2131
1A5780 Dimensional data
3.18 0.125
- BASE 6.88 0.27 FUSECLIPS
SPECIFICATIONS
FUSECLIPS BRASS, NICKEL PLATED
BASE MATERIAL GLASS FILLED NYLON, UL RATED 94V-0
CURRENT RATING 15 AMPS
VOLTAGE RATING 500V AC
TEMPERATURE RATING -50°C TO 145°C -58°F 292°F
*Spg. Br. - spring bronze; BeCu - beryllium copper; cart. brass -cartridge brass
'Tor RoHS compliant version add "-R" option code suffix to part number.
r
5.08 0.200
5.08 0.200
ATM fuses - 1A5778 Dimensional data
3.66 0.144
4.47 3.66 0.176 0.144
1.57 0.062
1.57 0.062 y
0.086
T
1.65x0.05 DIA. HOLE 0.065 x 0.002 (TYP-4)
MOUNTING LAYOUT FOR 2 CLIPS
MATERIAL BRASS, NICKEL PLATED,072 THICK
Data Sheet: 2131
1A5779
11.18 6.440
1.90 0.075
3.96 0.156
r 14.68 7 1.24 0.578 raw
fi 4.75 0.187
"-BASE
3.18 0.125
1.57 0.062
SPECIFICATIONS
FUSECLIPS BRASS, NICKEL PLATED
BASE MATERIAL GLASS FILLED NYLON, UL RATED 94V-0
CURRENT RATING 15 AMPS
VOLTAGE RATING 500V AC ° TEMPERATURE RATING 50°C TO
4 °F 145 C
1.45 0.057
.295" (7.49mm)
330" (8.38mm)
(3.81mm)
0.08" ± 0.01" (2.03 ± 0.25mm)
-.090" (2.29mm)
4.45 0.175
19.30 0.760
11.10 0.437
6.35 0.250
1.27 0.050
.053" (1.35mm)
(5.08mm)
3.66 0.144
2.54 0.100
3-15
Low voltage
supplementary
fuses
3Low voltage, supplementary fusesAutomotive blade-type fuses and PCB fuseclips
BUSSMANN SERIES FULL LINE CATALOG 1007—July 2015 Eaton.com/bussmannseries
Data Sheet: 2131
Data Sheet: 2131
Data Sheet: 2131
Catalog ClipNumber Mat.* Finish
1A5600 Cart. Satin Brass Finish Tin
ATC fuses (0 to 20 amps)1A5600
Dimensional data
ATM fuses - 1A5778Dimensional data
1A5779
1A5780Dimensional data
.150"(3.81mm)
.330"(8.38mm)
.295"(7.49mm)
.200"(5.08mm)
.053"(1.35mm)
0.08" ± 0.01"(2.03 ± 0.25mm)
.090" (2.29mm)
MOUNTING LAYOUT FOR 2 CLIPS
0.0120.30MATERIAL: BRASS, NICKEL PLATED, THICK
1.900.075
0.1563.96
0.44011.18
4.980.196
0.1253.18
1.570.062
0.0621.57
2.180.086
3.660.144
(TYP-4)
1.65 ± 0.050.065 ± 0.002 DIA. HOLE
0.1443.66
0.1764.47 3.66
0.144
BASE
FUSECLIPS
14.680.578
4.750.187
1.450.057
1.240.049
0.3408.64
0.1002.54
03.660.144
3.180.125
1
0.0621.573
MOUNTING LAYOUT
(TYP-4)
1.65 ± 0.050.065 ± 0.002 DIA. HOLE
0.1443.66
0.1764.47 3.66
0.144
SPECIFICATIONS
. .
. . . . .
. . . . .
. . . . . . . . . . . . .
UL RATED 94V-0
BRASS, NICKEL PLATEDGLASS FILLED NYLON,
500V AC15 AMPS
145ºC292ºFTO-50ºC
-58ºFTEMPERATURE RATING
VOLTAGE RATING CURRENT RATING
FUSECLIPS BASE MATERIAL
292ºF-58ºF
SPECIFICATIONS
. .
. . . . .
. . . . .
. . . . . . . . . . . . .
MOUNTING LAYOUT
UL RATED 94V-0
BRASS, NICKEL PLATEDGLASS FILLED NYLON,
500V AC15 AMPS
145ºCTO-50ºCTEMPERATURE RATING
VOLTAGE RATING CURRENT RATING
FUSECLIPS BASE MATERIAL
19.300.760
3.180.125
5.080.200
BASE
FUSECLIPS
4.450.175
6.350.250
0.2716.88
0.43711.10
0.0501.27
(TYP-4)
2.54 ± 0.050.100 ± 0.002 DIA. HOLE
0.2005.08
0.1604.06
*Spg. Br. - spring bronze; BeCu - beryllium copper; cart. brass - cartridge brass
***For RoHS compliant version add “-R” option code suffix to part number.
Data Sheet: 2131
ATR micro fuse
Specifications:Description: Fast-acting color coded 2-leg micro blade fuse.Construction: Colored plastic housing with zinc fuse element.Ratings:Volts — 32VdcAmps — 5-30A
IR — 1000A
Features and benefits:• Space-savings size• Industry standard color coding for easy identification of fuse ratings
Typical applications:• Automotive
Catalog numbers - (amps)
Catalog numbers Color
ATR-5 Tan
ATR-7-1/2 Brown
ATR-10 Red
ATR-15 Blue
ATR-20 Yellow
ATR-25 Clear
ATR-30 Green
// •• //) Fuses Made Simple'
Control circuit fuses AIP
a
The easiest and fastest way to select and specify the right control circuit fuse.
E:7•111 Powering Business Worldwide
346 BUSSMANN SERIES FULL LINE CATALOG 1007—July 2015 Eaton.corn/bussmannseries 3-16 BUSSMANN SERIES FULL LINE CATALOG 1007—July 2015 Eaton.com/bussmannseries
The easiest and fastest way to select and specify the right control circuit fuse.
Fuses Made Simple™Control circuit fuses