CONTENTS · 7. RCCB and RCBO (Earth Leakage Units) 7.1. Specifications IEC 61008 / 61009 and SABS...

29
CONTENTS 2 Introduction Technical Information 13mm Module Width QA Mini Rail Mounted MCB’s QA Mini Rail Mounted Switch Disconnectors and Earth Leakages QA DIN Rail Mounted MCB’s QA DIN Rail Mounted Switch Disconnectors and Earth Leakages QF Dual Mounted MCB’s QF Dual Mounted Switch Disconnectors and Earth Leakages QF DIN Rail Mounted MCB’s QF DIN Rail Mounted Switch Disconnectors and Earth Leakages QL Dual Mounted MCB’s QY Dual Mounted MCB’s (DC) 18mm Module Width QF DIN Mounted MCB’s 19,5mm Module Width QF Dual Mounted MCB’s Accessories Mounting Wiring and Installation Tripping Characteristics Auxiliary Products Electronic Time Switches Gapped Surge Arrestors Latching Unit and Controller Mounting and Installation Handle Lock 3 4 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 25 26 27 28 29 30 October 2000

Transcript of CONTENTS · 7. RCCB and RCBO (Earth Leakage Units) 7.1. Specifications IEC 61008 / 61009 and SABS...

  • CONTENTS

    2

    Introduction

    Technical Information

    13mm Module WidthQA Mini Rail Mounted MCB’sQA Mini Rail Mounted Switch Disconnectors and Earth LeakagesQA DIN Rail Mounted MCB’sQA DIN Rail Mounted Switch Disconnectors and Earth LeakagesQF Dual Mounted MCB’sQF Dual Mounted Switch Disconnectors and Earth LeakagesQF DIN Rail Mounted MCB’sQF DIN Rail Mounted Switch Disconnectors and Earth LeakagesQL Dual Mounted MCB’sQY Dual Mounted MCB’s (DC)

    18mm Module WidthQF DIN Mounted MCB’s

    19,5mm Module WidthQF Dual Mounted MCB’s

    Accessories

    Mounting

    Wiring and Installation

    Tripping Characteristics

    Auxiliary ProductsElectronic Time SwitchesGapped Surge ArrestorsLatching Unit and Controller

    Mounting and InstallationHandle Lock

    3

    4

    6789

    101112131415

    16

    17

    18

    19

    20

    21

    25262728

    2930

    October 2000

  • INTRODUCTION

    3

    1. APPLICATION

    Note that the IEC60898 products are not for use in the sub-Saharan Africa market.

    The QA and QF range of miniature circuit breakers are for use against overloads and short circuits in residential andcommercial electrical installations.

    The standard products are for use in 240V AC systems or 125V DC systems. The QA and QF earth leakage units arefor protection against fire and shock hazards in residential and commercial installations, and have a number of newfeatures.

    The Q range is complemented by a number of auxiliary products for energy management, switching of loads, andprotection against surges.

    2. PRINCIPLE OF OPERATION

    2.1. Time Delay OperationAt an overcurrent flow, the magnetic force produced bythe coil overcomes the core spring, the core closes to thepole piece, attracts the armature, and actuates the tripbar. The delay is obtained by the viscosity of the oil.

    2.2. Instantaneous OperationIf the overcurrent is excessive, the armature is instantlyattracted, without the influence of the moving core.

    MAGNETIC-MAGNETIC CIRCUIT BREAKER

    3. CONSTRUCTION

    3.1. Operating Handle -ON / TRIP / OFF operation. Resetting after tripping isperformed by returning the handle to the “OFF” position andthen “ON” again.

    Trip Free Operation - Even if the handle is held in the “ON”position, the breaker will trip if an overcurrent flows.

    Positive “ON” and Positive “OFF” mechanism - Shouldthe contacts weld in the closed position due to an abnormalcondition, the tripping mechanism will trip but the handle willremain in the “ON” position indicating that the circuit is stillclosed. Under these conditions, the handle cannot bemoved to the “OFF” position.

    3.2. Arc Extinguishing Device - Comprises a set ofspecially shaped steel grids isolated from each other. Amagnetic field is induced in the grids by the current flow anddraws the arc into the grids so that it is lengthened, cooledand split into a series of smaller arcs which are more easilyextinguished.

    MINIATURE CIRCUIT BREAKER (MCB)

    Normal Operation

    Movement OperatesTripping Mechanism

    ArmatureFrame

    Line

    Tube

    Contacts

    Trip Latch

    CoilSpring

    Core

    Flexible LoadPole

    Oil

    Load

    ARC EXTINCTION

    Magnetic Flux

    Arc

    GridMagnetic Force

    Line Terminal

    Fixed Contact

    Handle

    MechanismAssembly

    CoilMagneticFrame

    Load Terminal

    Contact Tips

    Arc RunnerLine Side

    Arc RunnerLoad Side

    Arc GridsArmature

    Clip-in Spring

    Moving Contacts

  • TECHNICAL INFORMATION

    4

    4.2 Earth Leakage Units

    • 3 Year warranty.• Current ratings up to 63A.• Guaranteed operation for voltages down to 50V AC.• Immune to pulsating DC.• Detects and trips if the neutral is not present.• Detects and trips if the neutral potential rises above 50V over earth potential.• Detects and trips if line and neutral are reversed.• Detects and trips if the line to neutral voltage exceeds a predetermined value (special types only).• Detects if the earth potential is not present.• Short time delay to avoid nuisance tripping.• One device covers all nominal voltages from 100 - 240V AC.• Operates normally even if reverse fed.• Insulation resistance testing can be done with the handle in either the ON or OFF position. When the

    handle is in the ON position, the functional earth wire should be disconnected. The test voltage appliedwith the megger must not exceed 500V.

    • Indication for ON - OFF - overload trip - earth leakage trip.• Although a functional earth connection is used, there is no current flow to earth during normal operation.• Current limiting on overload type.

    4. FEATURES

    4.1. Circuit breakers and switch disconnectors

    • Handle trips to mid position, on circuit breaker and earth leakage units to indicate that the unit has trippedfor an electrical fault and has not been switched off manually.

    • Convenient rail mounting for mini-rail, USA rail, DIN rail and surface mounting.• Circuit breakers can carry 100% of rated current and always trip within pre-determined percentage of rated current irrespective of ambient temperature conditions.• The operation is not dependent on thermal action to activate the tripping mechanism, therefore the

    predetermined trip current is not changed by a variation in temperature. The tripping characteristic ismainly determined by the number of turns of the solenoid coil.

    • No thermal de-rating of current necessary up to a maximum of 60°C ambient.• Non-standard current ratings are available - even fractions of ampere rating.• A wide variety of tripping characteristics are available to suit particular needs and giving reliable protection.• No nuisance tripping caused by high ambient temperatures.• Immediate reset after fault has been cleared.• No ageing or deterioration of sensing mechanism which is hermetically sealed.• 10 Year warranty.• Current ratings up to 63A.• Compact size, 13mm, 18mm and 19,5mm module widths.• Single phase loading does not affect the tripping characteristic of a multipole circuit breaker.• Circuit breakers have been tested and conform to the requirements to be used as disconnectors.• Magnetic-magnetic principle, with internal and external linkage to a common trip of multipole units, to ensure all poles trip simultaneously.• Easy to connect box terminals (25mm2 cable maximum), to a torque of 2,5Nm.

    5. TECHNICAL DATA

    5.1. All Q Range circuit breakers, switch disconnectors and earth leakage units have been fully tested in accordance withnational and international standards.

    5.2. The Q Range of circuit breakers are current limiting - When an overcurrent causes the breaker to trip an arc is drawnand is quickly extinguished. A magnetic field is introduced in the grids by the current flow and draws the arc into the gridsso that it is lengthened, cooled and split into a series of smaller arcs which are more easily extinguished.

  • TECHNICAL INFORMATION

    5

    5.3. Overcurrent Trip Curve Selection

    6. Circuit Breakers and Switch Disconnectors

    6.1 Handle Colour Circuit Breakers - White Switch Disconnectors - Green Single pole and neutral - White / Green

    6.2. Interrupting Capacity Ratings (kA)

    Note:SABS 156 tests are carried out at 110% of nominalvoltage and power factor 0,45 - 0,5.

    6.3. Rated Service Life (Operations) AC only

    CURVE No.

    MCB RATEDCURRENT

    (AMP)

    No. OF OPERATING CYCLES(Cycle = ON / OFF

    6 times per minute)

    TIME DELAYINSTANTANEOUS

    (Short circuit)NON TRIPPING

    CURRENTTRIPPINGCURRENT

    123BCD

    KM

    QA(13) up to 50QF(13) up to 25

    QF(18) / QF(19) up to 63A

    Mechanical4 000

    Electrical6 000

    Total10 000

    LongMedium

    ShortShort

    MediumLong

    Medium

    1.05 x In1.05 x In1.05 x In1.13 x In1.13 x In1.13 x In1.00 x In

    1.30 x In1.30 x In1.30 x In1.45 x In1.45 x In1.45 x In1.25 x In

    HighMediumLowLowMediumHighMedium

    10 - 15 x In5 - 10 x In3 - 5 x In3 - 5 x In

    5 - 10 x In10 - 15 x In6 - 12 x In

    Note:The tripping and the non-tripping current are not affected by the ambient temperature.In = Rated current of the MCB.

    .4. As per SABS 156, MCB’s have to comply with theoverload test which is 50 operations at 6 times ratedcurrent.

    6.5. Reverse Connection - MCB ’s and switchdisconnectors have been tested for, and comply with therequirements to be reverse connected.

    6.6. Frequency - MCB’s are suitable for 50/60Hzsystems.

    6.7. Switch disconnectors - All Q Range small frameswitch disconnectors are non-automatic circuit breakers,are fully rated and carry the associated circuit breakerfault current for 10ms. Protection must be provided by adevice upstream.

    7. RCCB and RCBO (Earth Leakage Units)

    7.1. Specifications IEC 61008 / 61009 and SABS 767

    7.2. Supply Voltages 220 / 240V AC single phase 220 / 240V AC single phase and neutral 380 / 415V AC three phase

    7.3. Clearance and Creepage Distances To IEC, SABS and UL.

    7.4. Frequency 50/60Hz

    7.5. Earth Leakage Unit Type NumberSuffix 15A = Single phase RCBO (white handle) -Single phase with two fully rated current paths, onefitted with overload.Suffix 15C = Single phase RCCB (green handle) -Single phase with two fully rated current paths, nooverload protection, which must be provided by adevice upstream.

    7.6. Sensitivity (mA) 30mA

    7.7. Vibration Resistance IEC 60571-1977.

  • QA 13mm MCB’s

    Product TypeStandard Ampere Ratings (A)

    Sensitivity (mA)Number of PolesEquipment TypeRated Voltage (V)

    RatedInterrupting/WithstandCapacity(kA)

    Mounting Options

    Weight (kg)Mechanism

    Tripping Curves (3 Standard)

    Wiring Diagrams

    QA-1(13)

    -1

    0,1

    QA-2(13)

    -2

    0,2

    QA-3(13)

    -3

    0,3

    Magnetic-Magnetic

    QA-N-2(13)

    -1Pole + Neutral

    0,2

    QA-N-4(13)

    -3Pole + Neutral

    0,4

    1* - 2* - 5 - 10 - 15 - 20 - 25 - 30 - 35 - 40 - 45 - 50 - 63*

    Mini RailDIN RailSurface ClipUSA Rail

    2 Breaking capacityto

    SABS156 andIEC60947-2

    2, 3(3), 2DC, 3DC(3) 2, 3(3),2DC, 3DC(3)

    2, 3(3) 2, 3(3)

    IEC60947-2SABS156IEC60947-3SABS152IEC61008IEC61009SABS767UL1077IEC60934(2)

    IEC60898UL489UL489-A

    230AC

    2,5

    400AC

    2,5

    400AC

    2,5

    230AC

    2,5

    400AC

    2,5

    240AC3

    415AC3

    415AC3

    240AC3

    415AC3

    Miniature Circuit Breaker277AC

    2

    480AC

    1

    480AC

    1

    277AC

    480AC

    125DC

    2

    250DC

    2 2

    125DC

    125DC

    QA-(13) MCB’s and Switch Disconnectors

    13

    13

    26 39 527466

    869315

    15

    519

    16

    57

    6

    *Subject to availability

    HWD

    1P861366

    2P862666

    3P863966

    4P865266

    2

    1x

    42 6

    5x x x

    31x

    2 N

    N1x x x

    42 6

    531 N

    N2 4

    31x x

  • QA 13mm SWITCH DISCONNECTORS, RCCB / RCBO’S

    QA-S-1(13)

    -1

    0,1

    QA-S-2(13)

    -2

    0,2

    Manual

    QA-S-3(13)

    -3

    0,3

    QA-S-4(13)

    -4

    0,2

    QA15A*10 - 15 - 20 - 30

    40 - 50 - 6030

    1Pole + NeutralEarth Leakage

    0,26Magnetic-

    Magnetic andEarth Leakage

    QA15C

    301Pole + NeutralEarth Leakage

    0,24Manual

    andEarth Leakage

    63 63

    230AC

    2,5

    230AC

    2,5

    240AC

    3

    240AC

    3

    230AC

    2,5

    400AC

    2,5

    400AC

    2,5

    400AC

    2,5

    QA15A / QA15C Earth Leakages

    L

    L

    N

    N

    16

    39

    86

    1517

    ,593

    57

    15

    6675

    255

    2, 3, B, C---- -

    *Subject to availability

    7

    HWD

    E/L863966

    Switch Disconnector

    2 4

    31

    2

    1

    62 4

    3 51

    2 64 8

    1 3 5 7

    N2

    1 N

    V

    1

    N2

    Nx

    V

  • QA 13mm DIN MCB’s

    QA-1(13)-D

    -1

    0,1

    QA-2(13)-D

    -2

    0,2

    QA-3(13)-D

    -3

    0,3

    Magnetic-Magnetic

    QA-N-2(13)-D

    -1Pole + Neutral

    0,2

    QA-N-4(13)-D

    -3Pole + Neutral

    0,4

    1* - 2* - 6 - 10 - 16 - 20 - 25 - 32 - 40 - 45 - 50 - 63*

    Mini RailDIN RailSurface ClipUSA Rail

    2, 3(3), B, C, 3DC(3) 2, 3(3), B, C 2, 3(3), B, C2, 3(3), B, C,3DC(3)

    IEC60947-2SABS156IEC60947-3SABS152IEC61008IEC61009SABS767UL1077IEC60934(2)

    IEC60898UL489UL489-A

    230AC

    2,5

    400AC

    2,5

    400AC

    2,5

    230AC

    2,5

    400AC

    2,5

    240AC3

    3*

    415AC3

    3*

    415AC3

    3*

    240AC3

    3*

    415AC3

    3*

    277AC

    2

    480AC

    1

    480AC

    1

    277AC

    480AC

    125DC

    2

    250DC

    2

    125DC

    125DC

    Product TypeStandard Ampere Ratings (A)

    Sensitivity (mA)Number of PolesEquipment TypeRated Voltage (V)

    RatedInterrupting/WithstandCapacity(kA)

    Mounting Options

    Weight (kg)Mechanism

    Tripping Curves (3 Standard)

    Wiring Diagrams

    7365

    869315

    15

    519

    16

    QA-(13)-D MCB’s and Switch Disconnectors

    45

    13

    13

    26 39 52

    *Subject to availability

    8

    2 Breaking capacityto

    SABS156 andIEC60947-2

    HWD

    1P861365

    2P862665

    3P863965

    4P865265

    Miniature Circuit Breaker

    42 6

    5x x x

    31x

    2 N

    N1x x x

    42 6

    531 N

    N2

    1x

    2 4

    31x x

  • QA 13mm DIN SWITCH DISCONNECTORS, RCCB / RCBO’S

    QA-S-1(13)-D

    -1

    0,1

    QA-S-2(13)-D

    -2

    0,2

    Manual

    QA-S-3(13)-D

    -3

    0,3

    QA-S-4(13)-D

    -4

    0,2

    QA15A-D*10 - 16 - 20 - 32

    40 - 50 - 6330

    1Pole + NeutralEarth Leakage

    0,26Magnetic-

    Magnetic andEarth Leakage

    QA15C-D

    301Pole + NeutralEarth Leakage

    0,24Manual

    andEarth Leakage

    -

    63

    Switch Disconnector

    63

    230AC

    2,5

    230AC

    2,5

    240AC

    3

    240AC

    3

    240AC

    3

    415AC

    3

    415AC

    3

    415AC

    3

    QA15A-D / QA15C-D Earth Leakages

    L

    L

    N

    N

    36

    8645

    1517

    .515

    93

    7565

    165

    25

    *Subject to availability

    9

    2, 3(3), B, C

    HWD

    E/L863665

    ----

    2 4

    31

    62 4

    3 51

    2 64 8

    1 3 5 7

    2

    1

    N2

    1 N

    V

    1

    N2

    Nx

    V

  • QF 13mm MCB’s

    Product TypeStandard Ampere Ratings (A)

    Sensitivity (mA)Number of PolesEquipment TypeRated Voltage (V)

    RatedInterrupting/WithstandCapacity(kA)

    Mounting Options

    Weight (kg)Mechanism

    Tripping Curves (3 Standard)

    Wiring Diagrams

    QF-1(13)

    -1

    0,1

    QF-2(13)

    -2

    0,2

    QF-3(13)

    -3

    0,3

    Magnetic-Magnetic

    QF-N-2(13)

    -1Pole + Neutral

    0,2

    QF-N-4(13)

    -3Pole + Neutral

    0,4

    1* - 2* - 5 - 10 - 15 - 20 - 25

    Miniature Circuit Breaker

    Mini RailDIN RailSurface ClipUSA Rail

    2(3), 3, 2DC(3) 2(3), 3, 2DC(3) 2(3), 3, 2DC(3)2(3), 3 2(3), 3

    IEC60947-2SABS156IEC60947-3SABS152IEC61008IEC61009SABS767UL1077IEC60934(2)

    IEC60898UL489UL489-A

    230AC

    5

    400AC

    5

    400AC

    5

    230AC

    5

    400AC

    5

    240AC6

    415AC6

    415AC6

    240AC6

    415AC6

    277AC

    2

    480AC

    1

    480AC

    1

    277AC

    480AC

    125DC

    3

    250DC

    3

    125DC

    3

    125DC

    7466

    869315

    1517

    .5

    525 16

    QF-(13) MCB’s and Switch Disconnectors

    57

    13

    13

    26 39 52

    10

    2 Breaking capacityto

    SABS156 andIEC60947-2

    *Subject to availability

    HWD

    1P861366

    2P862666

    3P863966

    4P865266

    2

    1x

    42 6

    5x x x

    31x

    2 N

    N1x x x

    42 6

    531 N

    N2 4

    31x x

  • QF 13mm SWITCH DISCONNECTORS, RCCB / RCBO’S

    QF-S-1(13)

    -1

    0,1

    QF-S-2(13)

    -2

    Switch Disconnector

    0,2

    Manual

    QF-S-3(13)

    -3

    0,3

    QF-S-4(13)

    -4

    0,2

    QF15A*10 - 15 - 20 - 30

    40 - 50 - 6030

    1Pole + NeutralEarth Leakage

    0,26Magnetic-

    Magnetic andEarth Leakage

    QF15C

    301Pole + NeutralEarth Leakage

    0,24Manual

    andEarth Leakage

    63 63

    230AC

    5

    230AC

    5

    240AC

    6

    240AC

    6

    230AC

    5

    400AC

    5

    400AC

    5

    400AC

    5

    QF15A / QF15C Earth Leakage

    L

    L

    N

    N

    16

    39

    86

    1517

    ,593

    57

    15

    6675

    255

    2(3), 3

    *Subject to availability

    11

    HWD

    E/L863966

    ---- -

    2 4

    31

    2

    1

    62 4

    3 51

    2 64 8

    1 3 5 7

    N2

    1 N

    V

    1

    N2

    Nx

    V

  • QF 13mm DIN MCB’s

    Product TypeStandard Ampere Ratings (A)

    Sensitivity (mA)Number of PolesEquipment TypeRated Voltage (V)

    RatedInterrupting/WithstandCapacity(kA)

    Mounting Options

    Weight (kg)Mechanism

    Tripping Curves (3 Standard)

    Wiring Diagrams

    QF-1(13)-D

    -1

    0,1

    QF-2(13)-D

    -2

    0,2

    QF-3(13)-D

    -3

    0,3

    Magnetic-Magnetic

    QF-N-2(13)-D

    -1Pole + Neutral

    0,2

    QF-N-4(13)-D

    -3Pole + Neutral

    0,4

    1* - 2* - 6 - 10 - 16 - 20 - 25

    Mini RailDIN RailSurface ClipUSA Rail

    2(3), 3, B, C(3),2DC(3)

    2(3), 3, B, C(3),2DC(3)

    2(3), 3, B, C(3) 2(3), 3, B, C(3),2DC(3)

    2(3), 3, B, C(3),

    IEC60947-2SABS156IEC60947-3SABS152IEC61008IEC61009SABS767UL1077IEC60934(2)

    IEC60898UL489UL489-A

    230AC

    5

    6

    230AC

    5

    6

    400AC

    5

    6*

    400AC

    5

    6*

    400AC

    5

    6*

    240AC6

    240AC6

    415AC6

    415AC6

    415AC6

    277AC

    277AC

    480AC

    480AC

    480AC

    125DC

    3

    250DC

    3

    125DC

    3

    125DC

    7365

    869315

    15

    519 16

    QF-(13)-D MCB’s and Switch Disconnectors

    45

    13

    13

    26 39 52

    12

    2 Breaking capacityto

    SABS156 andIEC60947-2

    *Subject to availability

    Miniature Circuit Breaker

    HWD

    1P861365

    2P862665

    3P863965

    4P865265

    2

    1x

    42 6

    5x x x

    31x

    2 N

    N1x x x

    42 6

    531 N

    N2 4

    31x x

  • QF 13mm DIN SWITCH DISCONNECTORS, RCCB / RCBO’S

    QF-S-1(13)-D

    -1

    0,1

    QF-S-2(13)-D

    -2

    0,2

    Manual

    QF-S-3(13)-D

    -3

    0,3

    QF-S-4(13)-D

    -4

    0,2

    QF15A-D*10 - 16 - 20 - 32

    40 - 50 - 6330

    1Pole + NeutralEarth Leakage

    0,26Magnetic-

    Magnetic andEarth Leakage

    QF15C-D

    301Pole + NeutralEarth Leakage

    0,24Manual

    andEarth Leakage

    63

    Switch Disconnector

    63

    230AC

    5

    230AC

    5

    240AC

    6

    240AC

    6

    240AC

    6

    415AC

    6

    415AC

    6

    415AC

    6

    QF15A-D / QF15C-D Earth Leakages

    L

    L

    N

    N

    36

    8645

    1517

    .515

    93

    7565

    165

    25

    2(3), 3

    *Subject to availability

    13

    HWD

    E/L863665

    ---- -

    2 4

    31

    2

    1

    62 4

    3 51

    2 64 8

    1 3 5 7

    N2

    1 N

    V

    1

    N2

    Nx

    V

  • QL 13mm MCB’s

    Product TypeStandard Ampere Ratings (A)

    Sensitivity (mA)Number of PolesEquipment TypeRated Voltage (V)

    RatedInterrupting/WithstandCapacity(kA)

    Mounting Options

    Weight (kg)Mechanism

    Tripping Curve (3 Standard)

    Wiring Diagrams

    QL-1(13)

    -1

    MCB120AC

    10

    0,1

    Magnetic-Magnetic

    KM(3)

    QL-2(13)*

    -2

    MCB240AC

    10

    0,2

    1 -2 - 5 - 1015 - 20 - 25

    5 - 1015 - 20 - 25

    Mini RailDIN RailSurface ClipUSA Rail

    IEC60947-2SABS156IEC60947-3SABS152IEC61008IEC61009SABS767UL1077IEC60934(2)

    IEC60898UL489UL489A

    QL-(13) MCB’s

    13 267466

    20

    45

    9357

    71.4

    82.4

    *Subject to availability

    14

    2 Breaking capacityto

    SABS156 andIEC60947-2

    HWD

    1P861366

    2P862666

    2

    1x

    2 4

    31x x

    13

  • QY 13mm MCB’s (DC)

    QY-N10-1(13)

    -1

    80DC

    10

    0,1

    U2(3)

    QY-N-N10-2(13)

    -1Pole + Neutral

    80DC

    10

    0,2

    U2(3)

    QY-IS-N10-1(13)*

    -1

    80DC

    10

    0,1

    Magnetic-Magnetic

    OP(3)

    QY-N10-1(13)-D

    -1

    80DC

    10

    0,1

    U2(3)

    QY-N-N10-2(13)-D

    -1Pole + Neutral

    80DC

    10

    0,2

    U2(3)

    QY-IS-N10-1(13)-D*

    -1

    80DC

    10

    0,1

    OP(3)

    1 - 2 - 6 - 10 - 16 - 2025 - 32 - 40 - 50

    6 - 10 - 16 - 20 25 - 32 - 40 - 50

    1 - 2 - 6 - 10 - 16 - 20 25 - 32 - 40 - 50

    1 - 2 - 6 - 10 - 16 - 20 25 - 32 - 40 - 50

    6 - 10 - 16 - 20 25 - 32 - 40 - 50

    1 - 2 - 6 - 10 - 16 - 20 25 - 32 - 40 - 50

    7365

    869315

    15

    519

    16QY-(13)-D MCB’s

    45

    13

    1313

    267466

    869315

    1517

    .5

    525 16

    QY-(13) MCB’s

    57

    13 26

    *Subject to availability

    15

    HWD

    HWD

    1P861365

    1P861366

    2P862665

    2P862666

    Miniature Circuit Breaker

    2

    1x

    2

    1x

    2

    1x

    2

    1x x

    2 N

    N1x

    2 N

    N1

  • QF 18mm DIN MCB’s

    Product TypeStandard Ampere Ratings (A)

    Sensitivity (mA)Number of PolesEquipment TypeRated Voltage (V)

    RatedInterrupting/WithstandCapacity(kA)

    Mounting Options

    Weight (kg)Mechanism

    Tripping Curves (3 Standard)

    Wiring Diagrams

    QF-1(18)-D

    -1

    0,1

    QF-2(18)-D

    -2

    0,2

    QF-3(18)-D

    -3

    0,3

    Magnetic-Magnetic

    QF-N-2(18)-D

    -1Pole + Neutral

    0,2

    QF-N-4(18)-D

    -3Pole + Neutral

    0,4

    1 - 2 - 6 - 10 - 16 - 20 - 25 - 32 - 40 - 50 - 63

    Mini RailDIN RailSurface ClipUSA Rail

    IEC60947-2SABS156IEC60947-3SABS152IEC61008IEC61009SABS767UL1077IEC60934(2)

    IEC60898UL489UL489-A

    230AC

    5

    230AC

    5

    400AC

    5

    400AC

    5

    400AC

    5

    240AC6

    6*

    240AC6

    6*

    415AC6

    6*

    415AC

    6

    6*

    415AC

    6

    6*

    277AC

    277AC

    480AC

    480AC

    480AC

    125DC

    3

    250DC

    3

    125DC

    3

    125DC

    36 54 72186860

    71.4

    7282.4

    45

    4419

    5 18

    QF-(18)-D MCB’s

    86

    16

    2 Breaking capacityto

    SABS156 andIEC60947-2

    1, 2(3), 3, 2DCB, C

    (3), D*1, 2(3), 3, 2DC

    B, C(3), D*

    1, 2(3), 3,B, C

    (3), D*1, 2(3), 3, 2DC

    B, C(3), D*

    1, 2(3), 3,B, C

    (3), D*

    Miniature Circuit Breaker

    HWD

    1P861865

    2P863665

    3P865465

    4P867265

    2

    1x

    42 6

    5x x x

    31x

    2 N

    N1x x x

    42 6

    531 N

    N2 4

    31x x

    *Subject to availability

  • QF 19,5mm MCB’s

    Product TypeStandard Ampere Ratings (A)

    Sensitivity (mA)Number of PolesEquipment TypeRated Voltage (V)

    RatedInterrupting/WithstandCapacity(kA)

    Mounting Options

    Weight (kg)Mechanism

    Tripping Curves (3 Standard)

    Wiring Diagrams

    QF-1(19)

    -1

    0,1

    QF-2(19)

    -2

    0,2

    QF-3(19)

    -3

    0,3

    Magnetic-Magnetic

    QF-N-2(19)

    -1Pole + Neutral

    0,2

    QF-N-4(19)

    -3Pole + Neutral

    0,4

    1 - 2 - 5 - 10 - 15 - 20 - 25 - 30 - 35 - 40 - 45 - 50 - 60

    Mini RailDIN RailSurface ClipUSA Rail

    IEC60947-2SABS156IEC60947-3SABS152IEC61008IEC61009SABS767UL1077IEC60934(2)

    IEC60898UL489UL489-A

    230AC

    5

    230AC

    5

    400AC

    5

    400AC

    5

    400AC

    5

    240AC

    6

    240AC

    6

    415AC

    6

    415AC

    6

    415AC

    6

    277AC

    277AC

    480AC

    480AC

    480AC

    125DC

    3

    250DC

    3

    125DC

    3

    17

    2 Breaking capacityto

    SABS156 andIEC60947-2

    1, 2(3), 3, 2DC(3) 1, 2(3), 3, 2DC(3) 1, 2(3), 3 1, 2(3), 3, 2DC(3) 1, 2(3), 3

    74 19.5 7858.53966

    1213

    5 1625

    5786

    QF-(19) MCB’s

    Miniature Circuit Breaker

    HWD

    1P861866

    2P863666

    3P865466

    4P867266

    2

    1x

    42 6

    5x x x

    31x

    2 N

    N1x x x

    42 6

    531 N

    N2 4

    31x x

  • ACCESSORIES

    18

    Accessory Type

    QA-(13)

    QA-S-(13)

    QA15AQA15C

    QA-(13)-D

    QA-S-(13)-D

    QA15A-DQA15C-D

    QF-(13)

    QF-S-(13)

    QF15AQF15C

    QF-(13)-D

    QF-S-(13)-D

    QF15A-DQF15C-D

    QL-(13)

    QY-(13)

    QF-(18)-D

    QF-(19)

    Note:(1) Available for single pole units only, with different pitches.(2) Available for single, double and triple pole units only, with different pitches.(3) 13mm Modules.(4) Subject to availability.

    Busbar singlephase 54 pole

    (1) (3)

    Busbar 3 phaseinsulated

    (2)

    Escutcheonblanks Handle lock

    Shrouds(1 to 8 pole)

    (3)

    Surfacemounting clip

    / screws

    SafetyBlanks

    (4)

  • MOUNTING

    19

    To install:Insert the topof the unit intothe mini raillip. Push theyellow clip atthe base ofthe unit toengage intothe mini rail.

    To remove:Use a screwdriverto pull the yellowclip down todisengage theunit.

    Pull unit slightlydown to withdrawunit from the minirail.

    Mini Rail Mounting

    DIN Rail Mounting

    ResidualCurrentDevice(Earth Leakage)

    MiniatureCircuitBreaker

    ResidualCurrentDevice(Earth Leakage)

    MiniatureCircuitBreaker

    To install:When the unit is inthe correct position,push yellow clip atthe base of the unitto engage the unit onthe DIN rail.

    To remove:Use screwdriver topull yellow clipdown to disengagethe unit.

  • WIRING AND INSTALLATION

    20

    1. Supply on the top, load on the bottom and RCCB/RCBO mounted on the right.

    Supply

    Supply

    Supply

    Supply

    Supply

    Load

    Load

    Load

    Load

    Load

    2. Supply on the top, load on the bottom and RCCB/RCBO mounted on the left.

    3. Supply on the bottom, load on the bottom andRCCB/RCBO mounted on the right.

    4. Supp ly on the top, load on the top and RCCB/RCBO mounted on the right.

    5. Supply on the bottom, load on the top and RCCB/RCBO mounted on the right.

  • TRIPPING CHARACTERISTICS

    21

    Sec

    onds

    Min

    utes

    (%) Rated Current

    1000

    100

    10

    1

    10

    1

    0.1

    0.01

    0.001

    100

    105

    130

    150

    200

    300

    400

    500

    1000

    1500

    2000

    2500

    3000

    4000

    5000

    Trip

    ping

    Tim

    e

    Operating CharacteristicsAmbient Temperature 30°C

    Curve 2

    Sec

    onds

    Min

    utes

    (%) Rated Current

    1000

    100

    10

    1

    10

    1

    0.1

    0.01

    0.00110

    010

    513

    015

    0

    200

    300

    400

    500

    1000

    1500

    2000

    2500

    3000

    4000

    5000

    Trip

    ping

    Tim

    e

    Operating CharacteristicsAmbient Temperature 30°C

    Curve 3

    Operating CharacteristicsAmbient Temperature 30°C

    Curve 1

    Sec

    onds

    Min

    utes

    (%) Rated Current

    1000

    100

    10

    1

    10

    1

    0.1

    0.01

    0.001

    100

    105

    130

    150

    200

    300

    400

    500

    1000

    1500

    2000

    2500

    3000

    4000

    5000

    Trip

    ping

    Tim

    e

  • Operating CharacteristicsAmbient Temperature 30°C

    Curve B

    Operating CharacteristicsAmbient Temperature 30°C

    Curve C

    Sec

    onds

    Sec

    onds

    Min

    utes

    Min

    utes

    (%) Rated Current (%) Rated Current

    1000 1000

    100 100

    10 10

    1 1

    10 10

    1 1

    0.1 0.1

    0.01 0.01

    0.001 0.001

    100

    100

    113

    113

    145

    145

    200

    200

    300

    300

    400

    400

    500

    500

    1000

    1000

    1500

    1500

    2000

    2000

    2500

    2500

    3000

    3000

    4000

    4000

    5000

    5000

    Trip

    ping

    Tim

    e

    Trip

    ping

    Tim

    e

    TRIPPING CHARACTERISTICS

    22

    Operating CharacteristicsAmbient Temperature 30°C

    Curve D

    Sec

    onds

    Min

    utes

    (%) Rated Current

    1000

    100

    10

    1

    10

    1

    0.1

    0.01

    0.001

    100

    113

    145

    200

    300

    400

    500

    1000

    1500

    2000

    2500

    3000

    4000

    5000

    Trip

    ping

    Tim

    e

  • 23

    TRIPPING CHARACTERISTICS

    1000

    100

    10

    1

    10

    1

    0.1

    0.01

    0.001

    100

    125

    150

    200

    300

    400

    500

    1000

    1500

    2000

    2500

    3000

    4000

    5000

    100

    10

    5

    1

    0.5

    0.1

    0.05

    0.01

    0.005

    0.001

    50 100

    150

    200

    300

    400

    500

    1000

    Operating CharacteristicsAmbient Temperature 40ºC

    Curve KM

    Operating CharacteristicsRCCB/RCBO

    Ambient Temperature-10 to +60ºC

    Sec

    onds

    Sec

    onds

    Min

    utes

    (%) Rated Current (%) Rated Sensitivity

    Trip

    ping

    Tim

    e

    Trip

    ping

    Tim

    e

    500

    400

    300250

    200175150125

    100

    75

    50

    40

    3025

    2017.5

    1512.5

    10-10-20 0 10 20 30 40 50 60 70 80

    Trip Time -Ambient Temperature

    Compensation forMagnetic-Magnetic

    Circuit Breakers

    Ambient Temperature

    Ambient Temperature30ºC

    (%)

    Ope

    ratio

    n T

    ime

  • TRIPPING CHARACTERISTICS

    24

    Sec

    onds

    Sec

    onds

    Min

    utes

    Min

    utes

    (%) Rated Current (%) Rated Current

    Trip

    ping

    Tim

    e

    Trip

    ping

    Tim

    e

    Operating CharacteristicsAmbient Temperature 30°C

    Curve OP(DC)

    (4% Ripple Factor)

    0.01

    0.1

    1

    10

    1

    10

    100

    1000

    150

    130

    130

    100

    105

    105

    200

    300

    255

    400

    500

    1000

    1500

    2000

    2500

    3000

    4000

    5000

    Operating CharacteristicsAmbient Temperature 30°C

    Curve U2(DC)

    (4% Ripple Factor)

    0.01

    0.1

    1

    10

    1

    10

    100

    1000

    150

    100

    200

    300

    255

    400

    500

    1000

    1500

    2000

    2500

    3000

    4000

    5000

    (%) Rated Current(%) Rated Current

    Trip

    ping

    Tim

    e

    Trip

    ping

    Tim

    e

    Min

    utes

    Min

    utes

    Seco

    nds

    Seco

    nds

    0.010.01

    10001000Operating Characteristics

    Ambient Temperature 30°C

    Curve 3-DC

    (4% Ripple Factor)

    Operating CharacteristicsAmbient Temperature 30°C

    Curve 2-DC

    (4% Ripple Factor)

    0.10.1

    11

    1010

    11

    1010

    100100

    145

    150

    113

    145

    100

    100

    113

    200

    200

    300

    300

    255

    400

    400

    500

    500

    1000

    1000

    1500

    1500

    2000

    2000

    2500

    2500

    3000

    3000

    4000

    4000

    5000

    5000

  • AUXILIARY PRODUCTS

    25

    Latching Unit and Controller

    • Compact size

    • Service Life: Minimum 10 000 operations at full load (0,75pf)

    • Degree of protection: IP41

    • Operating range: -20°C to +60°C

    • High current ratings

    • Robust (few moving parts)

    • Easy to install and connect

    • Indication shows when the main contacts are in the closed position

    FEATURES

    Electronic Time Switches

    • Compact size

    • Simple setting of Times and Programs

    • Units suitable for use in Residential, Commercial and Industrial applications

    • Non-reserve units have capacitors on the PCB’s to ride through any voltage dips or short interruptions

    • Service life: 25 000 operations at full load

    • Degree of protection: IP41

    • Protective lift-up cover

    • Display on main screen serves as a real time clock

    • All time switches have a by-pass / override switch

    • Type of contact: Single pole normally open on load side (Note: Not potential free contacts)

    • Low power consumption

    • Temperature range: -20°C to +55°C

    • 30 Minute time interval settings

    Gapped Surge Arrestors

    • Compact size

    • Convenient mounting

    • Outdoor type GSAW resistant to environmental conditions

    • Gapped type with non-linear silicon carbide resistor

    • No leakage current and potential thermal runaway problems

  • AUXILIARY PRODUCTS: ELECTRONIC TIME SWITCHES

    QAT-DM30 Minutes

    -

    Mini + DIN Rail39mm x 57mm

    220/240V rms 50Hz21 Amps RESISTIVE at 230V AC10 Amps INDUCTIVE at 230V AC

    DIN Rail36mm x 45mm

    QAT-R-DM30 Minutes12 Hours

    QAT-D30 Minutes

    -

    QAT-R-D30 Minutes12 Hours

    Product TypeDaily setting intervalsPower failure reserveRated VoltageRated Current(Do not exceed)MountingEscutcheon (W x H)Installation Wiring Diagram

    SUPPLY

    (230V)LOAD

    TIME SWITCH

    MAX LOAD: 21A RESISTIVE 10A INDUCTIVE

    N

    L

    L

    L230V ONLY

    QAT-R-DM

    LOAD

    L

    L L N

    N

    NE

    UT

    RA

    L B

    AR

    SUPPLY

    (230V)LOAD

    TIME SWITCH

    MAX LOAD: 21A RESISTIVE 10A INDUCTIVE

    N

    L

    L

    L230V ONLY

    QAT-R-D

    LOAD

    L N

    NE

    UT

    RA

    L B

    AR

    Alternative “N”connection

    57.0

    82.0

    66.0

    45.0

    QAT-DM & QAT-R-DM Escutcheon

    QAT-D & QAT-R-D Escutcheon

    Electronic Time Switches - Mini and DIN Rail mounted39.0 - Mini Rail

    36.0 -Din

    SUPPLY

    (230V)LOAD

    TIME SWITCH

    MAX LOAD: 21A RESISTIVE 10A INDUCTIVE

    N

    L

    L

    L230V ONLY

    QAT-R-DM

    26

    HWD

    Mini823966

    DIN823666

    NOTE:4 - Terminal device can be wired as a3 - terminal device

    4 - Terminal wiring

    N

    3 - Terminal wiring

  • 540*

    Surface2,5mm2

    Product Type

    Nominal discharge current (8/20us) kA

    MountingMaximum cable sizeRated VoltageNumber of PolesMin. power frequency sparkover voltageMax. power frequency sparkover voltageMax. front wave impulse sparkover voltageInstallation Wiring Diagrams

    QA

    L-10

    QA

    L-25

    QA

    L-40

    GS

    AW

    -10

    GS

    AW

    -25

    GS

    AW

    -40

    GS

    AE

    -25

    GS

    AE

    -40

    GS

    AE

    -65

    1,510

    2,525

    Mini and DIN Rail25mm2

    540*

    1,510

    2,525

    Bracket2,5mm2

    Single pole800V (50Hz) rms

    1 200V (50Hz) rms2 500V (Peak)

    540*

    2,525

    565*

    Indoor Boards Outdoor Use Equipment

    QAL GSAE

    Dia. 4 41 17

    12

    58 57

    2

    35.5

    19.6

    Dia. 43.3

    41.8

    GSAW

    INDOORSURGE

    ARRESTER

    26.5

    INDOORSURGE

    ARRESTER

    11.4

    66

    16 21.7

    8269 57

    Peak value high impulse current (4/10us) kA

    AUXILIARY PRODUCTS: GAPPED SURGE ARRESTORS

    27

    *Excluding bracket

    *Subject to availability

    L L

    L N

    HWD

    HDia.

    HWD

    454117

    41*46

    822666

    Single pole800V (50Hz) rms1 200V (50Hz)2 500V (Peak)

    Single pole800V (50Hz) rms1 000V (50Hz)2 500V (Peak)

    240V AC 50/60Hz (280V rms maximum continuous) 440V AC

  • QLUC-L-M230V rms 50Hz

    160 - 253V 50Hz100A RESISTIVE

    1 Operating Cycle per Minute230V rms 50Hz

    1mAMini Rail

    39mm x 57mm

    Product TypeSupply VoltageOperating RangeMaximum LoadMaximum Operating FrequencyTrigger signal

    MountingEscutcheon (W x H)

    Typical Installation Wiring Diagrams

    AUXILIARY PRODUCTS: LATCHING UNIT AND CONTROLLER

    28

    LOAD

    L

    N

    Latching UnitandController

    QLUC

    LED

    Trigger Signal

    ControlSwitch

    Nominal Voltage Rated Current

    Latching Unit and Controller

    L1

    L2

    L3

    N

    Latching UnitandController(3 off QLUC units)

    QLUC QLUC QLUC

    LED LED LED

    Individual load circuits

    Trigger signals

    Relay switch(LA/230V)

    Control switch(Daylight or

    Time Switch)

    50Hz 400V

    Multi-circuit configuration with common trigger

    HWD

    863966

    7.8

    67.2

    2039

    57 86

    1666

  • AUXILIARY PRODUCTS: MOUNTING AND INSTALLATION

    29

    Mini Rail

    Slide yellow clip up anddown as indicated

    to install and removethe unit.

    DIN Rail

  • HANDLE LOCK

    FEATURES• Moulded in self extinguishing yellow thermoplastic.• Can accommodate up to three padlocks with a 3mm

    shank diameter.• Can be used on single and multipole units.• Can be fitted to switches as well as MCB’s.• Locking mechanism does not impede the internal

    tripping action of the breaker of RCD.

    ApplicationThe handle lock can be used to lock the Q Range circuit breakers and earth leakage units (RCD’s) in either the “ON” or“OFF” position.

    Installation

    1. Open the locking lever by hinging it outwards.2. Push the lever towards the main body so that thewires protrude.

    To lock the breaker in the “OFF” position3. Squeeze the locking wires between the thumb andforefinger and clip wires into holes of handle guard.4. Move the main body towards the breaker until it fitssnugly in the recess above the handle. (Handle is in“OFF” position).5. Hinge the locking lever back into place.6. Insert up to three padlocks with a 3mm shankdiameter.

    To lock the breaker in the “ON” position3. Rotate handle lock 180°.4. Squeeze the locking wires between the thumb andforefinger and clip wires into holes of handle guard.5. Move the main body towards the breaker until it fitssnugly in the recess below the handle. (Handle is in“ON” position).6. Hinge the locking lever back into place.7. Insert up to three padlocks with a 3mm shankdiameter.

    Locking wire

    Main body

    Locking lever

    30

    Fit locking wirethrough handle guardholes

    Locking breaker in the “OFF” position

    Locking breaker in the “ON” position

    IntroductionTechnical Information13mm Module Width:QA Mini Rail Mounted MCB'sQA Mini Rail Mounted Switch Disconnectors, RCCB / RCBO'sQA Din Rail Mounted MCB'sQA Din Rail Mounted Switch Disconnectors, RCCB / RCBO'sQF Dual Mounting MCB'sQF Dual Mounting Switch Disconnectors, RCCB / RCBO'sQF Din Rail Mounted MCB'sQF Din Rail Mounted Switch Disconnectors, RCCB / RCBO'sQL Dual Mounting MCB'sQY Dual Mounting MCB's (DC)18mm Module Width:QF Din Mounted MCB's19.5mm Module Width:QF Dual Mounted MCB'sAccessoriesMountingWiring and InstallationTripping CharacteristicsAuxiliary ProductsElectronic Time SwitchesGapped Surge ArrestersLatching Unit and ControllerMounting and InstallationHandle Lock