CONSTRUCTION ISSUE WD-01B
Transcript of CONSTRUCTION ISSUE WD-01B
PROPOSED SINGLE STOREY DWELLING @LOT 739 PEAR PARADE, FRASER RISE
NOOR SABAH
Project
Sheet No.
Date.
Scale.
Title
Client:
Orientation.
MAY. 2021
* DO NOT SCALE THIS DRAWING.* FIGURED DIMENSIONS TO TAKE PRECEDENCEOVER SCALE. BUILDERS & CONTRACTORS TOVERIFY ALL DIMENSIONS ON SITE PRIOR TOCOMMENCEMENT OF WORKS.
NOTE:SITE & FLOOR LEVELS TO BE CONFIRMED ON SITEBY BUILDER PRIOR TO COMMENCEMENT OF ANYWORKS IF ANY DISCREPANCIES ARE FOUNDCONTACT OFFICE IMMEDIATELY
CONSTRUCTION ISSUEBD_210613
Dwg. No.
REV. No.REVISIONS
PRELIMINARY ISSUE26.07.2021 A
GREENZONE BUILDING DESIGN & THERMAL ASSESSMENT PTY.LTD
ARCHITECTURE DEVELOPMENT BUILDING & PLANNING PERMITS ENERGY RATING SECTION J BUSHFIRE REPORTS RESIDENTIAL COMMERCIAL INDUSTRIAL
E: [email protected] W: WWW.GREENZONE.NET.AU 143 MILITARY ROAD, AVONDALE HEIGHTS VIC 3034 P: 03 9331 0038 M: 0411 325 179
BBUILDING PERMIT ISSUE02.10.2021 B WD-01
GENERAL NOTES
1:100 @ A3
· GENERAL NOTES (CLASS 1A AND 10B)
· ARCHITECTURAL
· THESE DRAWINGS SHALL BE READ IN CONJUNCTION WITH THE ARCHITECTURAL SPECIFICATION AS WELL AS ALL
OTHER CONSULTANTS' DRAWINGS AND SPECIFICATIONS AND WITH ANY OTHER WRITTEN INSTRUCTIONS AS ISSUED
DURING THE COURSE OF THE BUILDING CONTRACT. ANY DISCREPANCY IN THESE DOCUMENTS MUST BE REFERRED
TO THE PROJECT ARCHITECT FOR RESOLUTION PRIOR TO PROCEEDING WITH THE WORK.
· DO NOT SCALE DRAWINGS. USE WRITTEN DIMENSIONS ONLY.
· AMENDMENTS TO DRAWINGS AND ANY WRITTEN INSTRUCTIONS OR PROJECT NOTES SHALL TAKE PREFERENCE
OVER THE SPECIFICATION.
· SET OF BUILDING PERMIT DOCUMENTATION TO BE KEPT ON SITE FOR REFERENCE AT ALL TIMES.
· BUILDER'S DRAWING SET ON SITE TO BE UPDATED AND MAINTAINED WITH THE LATEST REVISIONS AS SOON AS THE
DOCUMENTS FOR THE REVISIONS ARE ISSUED. THESE ARE AVAILABLE FOR ANY INSPECTIONS UNDERTAKEN.
· ALL WORK TO BE IN ACCORDANCE WITH LOCAL COUNCIL BY LAWS AND CURRENT NATIONAL CONSTRUCTION CODE
(BCA) AND LATEST AUSTRALIAN STANDARDS AND CODES WHERE APPLICABLE.
· ALL OVERALL SET OUT DIMENSIONS AND LEVELS SHALL BE OBTAINED FROM THE ARCHITECTURAL DRAWINGS AND
VERIFIED ON SITE PRIOR TO THE COMMENCEMENT OF ANY BUILDING WORKS. THIS SHALL INVOLVE CHECKING FROM
ALL BOUNDARIES AND ANY DISCREPANCY MUST BE REFERRED TO THE PROJECT ARCHITECT.
· ALL LEVELS AND PLAN DIMENSIONS TO BE VERIFIED BY BUILDER ON SITE. ALL SERVICES TO BE VERIFIED BY
BUILDER ON SITE. ANY DISCREPANCIES FOUND ON THE DRAWINGS ARE TO BE CLARIFIED WITH THE ARCHITECT
BEFORE PROCEEDING WITH ANY WORK.
· NO DIMENSIONS SHALL BE SCALED FROM THE DRAWINGS WITHOUT CONFIRMATION WITH THE PROJECT ARCHITECT
AND ALL DIMENSIONS MUST BE REFERRED TO THE PROJECT ARCHITECT.
· ALL LEVELS SHOWN ON THE DRAWINGS SHOULD INDICATE WHETHER TAKEN FROM FINISHED FLOOR OR
STRUCTURAL SURFACES, BUT GENERALLY ARE FROM FINISHED FLOOR. IF NOT STATED THESE SHOULD BE
CONFIRMED WITH THE PROJECT ARCHITECT.
· REFER TO ENGINEERING DOCUMENTATION FOR ALL STRUCTURAL DETAILS.
· INTERNAL CEILING HEIGHTS AS SPECIFIED ON DRAWINGS.
· NO PORTION OF THIS BUILDING IS TO PROJECT BEYOND ANY OF THE TITLE BOUNDARIES.
· SET DOWN IN FLOOR LEVELS (REDUCED LEVELS) RL: FLOOR LEVELS SHOWN ARE FINISHED REDUCED FLOOR
LEVELS.
· SET DOWN IN FLOOR LEVELS (FINISHED FLOOR LEVELS) FFL: FLOOR LEVELS SHOWN ARE FINISHED FLOOR LEVELS.
· THESE PLANS SHALL BE READ IN CONJUNCTION WITH ANY STRUCTURAL OR CIVIL ENGINEERING COMPUTATIONS
AND DRAWINGS.
· THESE PLANS SHALL BE READ IN CONJUNCTION ENERGY RATING ASSESSMENT FOR PROJECT BUILDER TO ENSURE
ALL REQUIREMENTS.
· ALL FINAL COLOUR SELECTION TO BE CONFIRMED WITH DESIGNER PRIOR TO CONSTRUCTION.
· LOCATION OF BULKHEADS, CONDENSOR UNITS, DUCTWORK, GRILLS TO BE APPROVED BY DESIGNER.
· BUILDING NOTES
· BEFORE CONSTRUCTION COMMENCES, A CONSTRUCTION MANAGEMENT PLAN MUST BE PREPARED BY THE BUILDER
AND APPROVED TO THE SATISFACTION OF THE RESPONSIBLE AUTHORITY IF REQUIRED.
· BUILDING(S) AND SITE TO BE LEFT CLEAN AND READY FOR OCCUPATION UPON COMPLETION OF ALL SITE WORKS.
· THE MAIN CONTRACTOR AND ALL SUB CONTRACTORS SHALL COMPLY WITH ALL APPLICABLE HEALTH AND SAFETY
CODES OF PRACTICE, GUIDANCE NOTES, AUSTRALIAN STANDARDS AND OTHER RELEVANT DOCUMENTATION.
· ALL EXCAVATION, TRENCHES FOR FOOTINGS, SEWERAGE, DRAINAGE ETC., TO BE CARRIED OUT IN ACCORDANCE
WITH CONTROLLING AUTHORITY'S REQUIREMENTS.
· ALL FITTINGS AND FIXTURES TO BE INSTALLED IN-ACCORDANCE WITH MANUFACTURER'S SPECIFICATION AND
INSTRUCTIONS.
· DESIGN OF RETAINING WALLS TO BE TO THE SATISFACTION OF ENGINEER AND OR IN ACCORDANCE WITH
MANUFACTURER'S REQUIREMENTS IN THE CASE OF A PROPRIETARY SYSTEM BEING USED.
· BUILDER TO ALLOW FOR SELECTED AIR CONDITIONING SYSTEM.
· ALL NEW GLAZING TO COMPLY WITH WITH AS1288-2006 AND AS2047-2014.
· SHOWER SCREENS AND GLAZING ADJACENT TO BATHS TO BE SAFETY GLASS.
· DESIGN AND CONSTRUCTION OF TIMBER FRAMING IN ACCORDANCE WITH AS 1684.2, 3 & 4 - 2010.
· ALL ROOMS THAT DO NOT HAVE NATURAL VENTILATION TO HAVE MECHANICAL VENTILATION IN ACCORDANCE
WITH AS1668.2-2012.
· MECHANICAL EXHAUSTS (25L/S) ARE REQUIRED IN THE SANITARY FACILITY ROOMS DISCHARGING DIRECTLY INTO
THE ROOF SPACE OR TO THE OUTSIDE VIA A DUCT OR ALTERNATIVE PIPING SYSTEM.
· EXHAUST AIR OUTLETS NOT TO BE LOCATED CLOSER THAN 6M TO FRESH AIR INLETS.
· MECHANICAL VENTILATION SYSTEM TO COMPLY WITH AS1668.2-2012 AND AS/NZS3666.1-2011.
· MINIMUM 2400MM CEILING HEIGHT TO ALL NEW PORTIONS OF CEILING.
· THE DOOR TO A FULLY ENCLOSED SANITARY COMPARTMENT MUST COMPLY WITH THE FOLLOWING IF THERE IS NOT
A CLEAR SPACE OF AT LEAST 1.2M BETWEEN CLOSET PAN AND NEAREST PART OF DOORWAY:
· OPEN OUTWARDS OR
· SLIDE OR
· BE READILY REMOVABLE FROM THE OUTSIDE OF THE SANITARY COMPARTMENT.
· ALL EXPOSED STEEL TO BE HOT DIPPED GALVANIZED.
· PROVIDE WATERPROOF MEMBRANE TANKING TO WET AREA FLOORS AND TILED SHOWER BASES AS REQUIRED. TO
BCA 3.8.1.1 AND AS 3740 - 2010
· INSULATION AS PER ENERGY RATING REPORT.
· TERMITE PROTECTION TO BE PROVIDED IN ACCORDANCE WITH AS 3660.1 - 2014.
· THE BUILDER IS TO ENGAGE THE SITE ENGINEER TO CHECK THE STABILITY OF THE EXISTING WALLS DURING
DEMOLITION.
· SHEET ROOF CLADDING TO BE DESIGNED AND INSTALLED IN ACCORDANCE WITH AS1562.1-1992.
· BUILDER TO RECTIFY ANY DAMAGE DURING CONSTRUCTION TO FOOTPATH, KERBS OR ROADS ETC TO THE
APPROVAL OF LOCAL AUTHORITIES. REDUNDANT CROSSOVERS TO BE REMOVED AND MATCHING KERB AND
CHANNEL, FOOTPATH, ETC TO BE REINSTATED TO APPROVAL OF COUNCIL.
· BRICK WORK/BLOCK WORK
· VERTICAL ARTICULATION JOINTS SHALL BE PROVIDED IN STRAIGHT, CONTINUOUS WALLS (HAVING NO OPENING) AT
NOT MORE THAN 6M CENTRES AND LOCATED NO CLOSER THAN THE HEIGHT OF THE WALL AWAY FROM THE
CORNERS. WHERE THE OPENINGS ARE MORE THAN 900 X 900 MM OCCUR. THEN THE ARTICULATION JOINTS ARE TO
BE REDUCED TO 5M CENTRES AND POSITIONED IN LINE WITH AT LEAST ONE EDGE OF THE OPENING. FURTHER MORE
THE ARTICULATION JOINTS SHOULD BE PROVIDED AT OR NEAR CHANGES IN FOUNDATION SOIL, AT DEEP REBATES
FOR PIPES, WHERE WALLS CHANGE IN THICKNESS AND BETWEEN NEW AND OLD BRICKWORK.
· PROVIDE CORRESPONDING CONTROL JOINTS IN RENDER FINISHES AND TO RECOMMENDATION OF MANUFACTURER.
DO NOT RENDER OVER CONTROL JOINTS. CONTROL JOINTS LOCATION REFERS TO GROUND FLOOR PLAN.
· FINISH TO JOINTS TO BE AS PER PROJECT SPECIFICATION TO SATISFACTION OF DESIGNER.
· WEEP HOLES MUST BE CREATED IN THE COURSE IMMEDIATELY ABOVE ANY DPC OR FLASHING AT CENTRES NOT
EXCEEDING 1.2M EXCEPT WHERE THE HEAD OR SILL OPENING IS LESS THAN 1.0M.
· INSTALL DPC, WALL TIES, REINFORCEMENT, FLASHING TO AS 3700.
· THE HEIGHT OF A DPC, OR FLASHING SERVING AS A DPC MUST NOT BE LESS THAN-
(· 150MM ABOVE THE ADJACENT GROUND LEVEL; OR
(· 75MM ABOVE THE FINISHED SURFACE LEVEL OF ADJACENT PAVED, CONCRETED LANDSCAPED AREAS THAT
SLOPE AWAY FROM THE WALL.
· CONCRETE NOTES
· ALL CONCRETE SLABS TO COMPLY WITH AS2870 - 2011 RESIDENTIAL SLABS & FOOTINGS REQUIREMENTS.
· CONCRETE TO HAVE A MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS OF FC 25 MPA UNLESS OTHERWISE
NOMINATED STRUCTURAL ENGINEER.
· THESE PLANS SHALL BE READ IN CONJUNCTION WITH THE SOIL REPORT. FOOTINGS TO BE FOUNDED AT THE
MINIMUM DEPTHS INDICATED IN THE SOIL REPORT, AND ENGINEER'S DRAWINGS. ADVISE DESIGNER IMMEDIATELY IF
CONFLICT EXISTS BETWEEN ARCHITECTURAL SPECIFICATIONS, RECOMMENDATIONS OF SOIL REPORT AND
ENGINEERS DRAWINGS.
· FOOTINGS ARE NOT TO ENCROACH OVER TITLE BOUNDARIES AND EASEMENT LINES. IT IS RECOMMENDED THAT
WHERE BUILDINGS ARE BUILT WITHIN CLOSE PROXIMITY OF TITLE BOUNDARIES A SURVEY BE CARRIED OUT BY A
LICENSED LAND SURVEYOR TO RE-ESTABLISH THE TITLE BOUNDARIES. ALL WORKS IN CLOSE PROXIMITY TO TITLE
BOUNDARY LINES TO BE CARRIED OUT IN ACCORDANCE WITH PROTECTION WORKS NOTICES TO THE SATISFACTION
OF THE RESPONSIBLE BUILDING SURVEYOR.
· CONCRETE AND STEEL PLACEMENT TO COMPLY WITH ENGINEER'S DESIGN AND COMPUTATIONS.
· TOP SOIL AND VEGETATION UNDER CONCRETE SLABS TO BE REMOVED.
· FOR POLISHED CONCRETE AREAS FLOOR AREAS ALLOWS FOR ADDITIONAL OF 50MM SCREED OVER STRUCTURAL
FLOOR LEVEL. ALL GARAGES TO HAVE SCREED FALL TOWARDS STRIP DRAIN OUTSIDE GARAGE DOOR. BUILDER TO
PROVIDE STRIP DRAIN OUTSIDE GARAGE DOORS.
· FOR WET AREA, PROVIDE 50MM SET DOWN FOR FALLS TO FLOOR WASTES WHERE NOMINATED. WET AREA INCLUDES
BATHROOMS, POWDER ROOM, LAUNDRY ROOM, ENSUITE. PROVIDE 1:60 MIN FALLS TO TILED SHOWER RECESSES.
· SLAB ON GROUND - FINISHED SLAB HEIGHTS.
· HEIGHT OF SLAB ON GROUND ABOVE EXTERNAL FINISHED SURFACES MUST BE NOT LESS THAN:
(· 100 MM ABOVE THE FINISHED GROUND LEVEL; OR
(· 50MM ABOVE IMPERMEABLE (PAVED OR CONCRETED AREAS) THAT SLOPES AWAY FROM THE BUILDING; OR
(· 150 MM IN ANY OTHER CASE.
· CLAUSE 5.6.3 (AS2870-2011) - DRAINAGE REQUIREMENTS FOR MODERATELY, HIGHLY & EXTREMELY REACTIVE SITES).
THE BASE OF TRENCHES SHALL BE SLOPED AWAY FROM THE BUILDING. TRENCHES SHALL BE BACKFILLED WITH
CLAY IN THE TOP 300MM WITHIN 1.5M OF THE BUILDING.
· WHERE PIPES PASS UNDER THE FOOTING SYSTEM, THE TRENCH SHALL BE BACKFILLED FULL DEPTH WITH CLAY OR
CONCRETE TO RESTRICT THE INGRESS OF WATER BENEATH THE FOOTING SYSTEM. WHERE PIPES PASS UNDER
THE FOOTING SYSTEM, THE TRENCH SHALL BE BACK FILLED FULL DEPTH WITH CLAY TO ACT AS A BARRIER TO THE
INGRESS OF WATER BENEATH THE FOOLING SYSTEM. ALTERNATIVELY, A PLASTIC MEMBRANE ACROSS THE CROSS
-SECTION OF THE TRENCH, TAPED TO THE PIPE AND KEYED INTO THE SIDE AND BASE OF THE TRENCH MAY BE USED.
· SUBSURFACE DRAINS TO REMOVE GROUNDWATER SHALL NOT BE USED WITHIN 1.5M OF THE BUILDING UNLESS
DESIGNED IN ACCORDANCE WITH ENGINEERING PRINCIPLES.
· DAMP PROOFING AND FLASHING:
· BRICK VENEER- PROVIDE DAMP-PROOF COURSE IN CAVITY WALL CONSTRUCTION BUILT ON CONCRETE SLAB. IN THE
BOTTOM COURSE OF OUTER LEAF, CONTINUOUS HORIZONTALLY ACROSS THE CAVITY AND UP THE INNER FACE
BEDDED IN MORTAR, TURNED 30MM INTO THE INNER LEAF ONE COURSE ABOVE, OR, IN MASONRY VENEER
CONSTRUCTION, FASTENED TO THE INNER FRAME 75MM ABOVE FLOOR LEVEL.
· PROVIDE A MINIMUM 150MM FREEBOARD LEVEL TO THE CONCRETE SLAB.
· ALL EXTERNAL WALLS TO BE LINED WITH ONE LAYER SARKING/ WATERPROOF MEMBRANE AND INSULATION BATTS
BETWEEN STUDS.
· PLUMBING AND DRAINAGE
· SEWER OR SEPTIC SYSTEM SHALL BE IN ACCORDANCE WITH THE RELEVANT AUTHORITY'S REQUIREMENTS.
· STORM WATER DRAINAGE TO BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH AS/NZS3500.3 - 2003.
· ROOF PLUMBER IS RESPONSIBLE FOR DESIGN, CONSTRUCTION AND CERTIFICATION OF ROOF DRAINAGE.
· HOT & COLD WATER SUPPLY PIPE WORK TO BE CONCEALED. HOT WATER PIPE WORK TO BE THERMALLY LAGGED.
· STORMWATER DRAINS TO BE TAKEN TO LAWFUL POINT OF DISCHARGE AS DIRECTED BY LOCAL COUNCIL.
· STORMWATER DRAINS TO BE IN ACCORDANCE WITH CIVIL ENGINEER'S DRAWINGS.
· ALL NEW STORMWATER DOWNPIPES ARE TO BE A MINIMUM 90 MM DIAMETER AND CONNECTED TO THE EXISTING
STORMWATER DRAINAGE SYSTEM, OR TO NEW HEAVY DUTY PVC 100MM STORM WATER PIPE WITH A MINIMUM 1:100
FALL AND MUST BE SPACED AT ENTRIES NOT EXCEEDING 12 METRES.
· PROVIDE THERMAL LINING BOARD (EG MILLBOARD) BEHIND GAS COOK TOPS WHERE SPLASHBACK ARE TO BE
INSTALLED AND COOK TOP BURNERS ARE WITHIN 200MM OF SPLASHBACK.
· SURFACE WATER DRAINAGE.
· THE EXTERNAL FINISHED SURFACE SURROUNDING THE SLAB MUST BE GRADED TO GIVE A SLOPE OF NOT LESS
THAN
(· 25 MM OVER THE FIRST 1 M FROM THE BUILDING FOR SURFACES THAT ARE REASONABLY IMPERMEABLE
OR
(· 50 MM OVER THE FIRST 1 M FROM THE BUILDING.
· STAIRS AND STEPS
· STAIRS TO COMPLY WITH FOLLOWING:
· RISERS TO HAVE A MAXIMUM HEIGHT OF 190 MM AND MINIMUM 115 MM.
· GOINGS TO HAVE A MAXIMUM TREAD WIDTH OF 355 MM AND MINIMUM 250 / 240MM.
· THE NOMINAL DIMENSION OF GOINGS AND RISERS OF A STAIR MUST BE CONSTANT THROUGHOUT EACH STAIR
FLIGHT.
· THE RATIO OF TWICE THE RISER HEIGHT PLUS THE TREAD WIDTH IS TO BE BETWEEN 550MM AND 700MM.
· BALUSTRADE HEIGHT TO BE MINIMUM 1M (OR 865 ABOVE THE LINE OF STAIR NOSINGS) TO ALL STAIRS AND
LANDINGS.
· FOR FLOORS MORE THAN 4M ABOVE THE GROUND, ANY HORIZONTAL ELEMENTS WITHIN THE BALUSTRADE OR
OTHER BARRIER BETWEEN 150MM AND 760MM ABOVE THE FLOOR MUST NOT FACILITATE CLIMBING.
· BALUSTRADE AND RISER OPENINGS TO BE LESS THAN 125MM.
· MINIMUM CLEAR HEIGHT OF STAIRS TO BE 2000MM FOR A MINIMUM CLEAR WIDTH OF 1000MM.
· HANDRAILS MUST BE LOCATED ALONG AT LEAST ONE SIDE OF THE STAIRS AND FIXED NOT LESS THAN 865MM
ABOVE THE NOSINGS OF THE STAIR TREADS AND FLOOR SURFACE OF THE LANDING OR THE LIKE.
· ALL TREADS, LANDINGS AND THE LIKE TO HAVE A SLIP-RESISTANCE CLASSIFICATION OF P3 OR R10 FOR DRY
SURFACE CONDITIONS AND P3 OR R11 FOR WET SURFACE CONDITIONS, OR A NOSING STRIP WITH A SLIP
RESISTANCE CLASSIFICATION OF P3 FOR DRY SURFACE CONDITIONS AND P4 FOR WET SURFACE CONDITIONS.
· NON SLIP FINISHES TO BE PROVIDED TO ALL STEPS, RAMPS AND LANDINGS IN ACCORDANCE WITH AS4586-2013.
· STEEL NOTES
· STRUCTURAL STEEL TO COMPLY WITH ENGINEER'S DESIGN AND COMPUTATIONS.
· STEEL LINTELS IN EXTERNAL WALLS AND ALL EXPOSED STRUCTURAL STEEL TO BE HOT DIPPED GALVANISED.
· A FIRE RATING LEVEL (FRL) OF 60/60/60 IS REQUIRED TO ALL LOAD BEARING PARTY WALL BETWEEN UNITS IN
ACCORDANCE WITH ENGINEER'S DRAWINGS.
· MINIMUM CORROSION PROTECTION FOR BUILT IN STRUCTURAL STEEL FOR A MEDIUM ENVIRONMENT
· BLAST TO GRADE 2.5/100 ΜM ZINC SILICATE TYPE 3 OR 6.
· HOT DIP GALVANISING - 600 G/M².
· HOT DIP GALVANISING - 300 G/M²/75ΜM EPOXY PHOSPHATE PRIMER//125 ΜM EPOXY MIO.
· MINIMUM PROTECTION FOR WALL TIES FOR AREAS 100 M OR MORE BUT LESS THAN 1 KM FROM SALT WATER NOT
SUBJECT TO BREAKING SURF:
· SHEET STEEL TIES GALVANISED AFTER MANUFACTURE - 470 G/M² OR EACH SIDE.
· GALVANISED WIRE TIES - 470 G/M² COATING MASS.
· MINIMUM CORROSION PROTECTION FOR STRUCTURAL STEEL MEMBERS NOT BUILT INTO A MASONRY WALL FOR A
MODERATE ENVIRONMENT:
· ANY EXPOSED STRUCTURAL STEELWORK IS TO BE HOT DIP GALVANISED E.G. LINTELS, WALL TIES ... WITHIN 1KM
OF
THE COASTLINE.
· TILING
· PROVIDE FLEXIBLE WATERPROOF CONTINUOUS SEAL BETWEEN FIXTURES, JOINERY AND TILE WORK FITTINGS,
PIPE WORK ETC.
· COLOUR TO MATCH GROUT.
· PROVIDE MATCHING SILICONE SEAL BETWEEN FLOOR AND WALL TILES.
· SILICONE COLOURS TO MATCH GROUT. REFER UNCERTAIN COLOUR MATCHES TO DESIGNER FOR RESOLUTION.
· PROVIDE WATER BAR AT ALL BATHROOMS, ENSUITE AND LAUNDRY DOORS AND UPTURN MEMBRANE BEFORE
LAYING SCREED AND TILES.
· PROVIDE FALLS IN FLOOR WITHIN WET AREAS WHERE FLOOR WASTES (FW) ARE INDICATED TO THE SATISFACTION
OF BUILDING SURVEYOR. PROVIDE ALUMINIUM ANGLE WATER BAR CHANGES OF FLOOR FINISHES IN WET AREAS.
TURN UP WATERPROOF MEMBRANE AT WATER BAR BEFORE LAYING SCREED TILE FINISH.
· PROVIDE WATERPROOF SEAL IN MATCHING COLOUR BETWEEN TILES AND FLOOR FINISHES OUTSIDE BATHROOM.
· FOR WET AREAS PROVIDE FLOOR WASTES WHERE NOMINATED. PROVIDE 1:60 MIN FALLS TO WASTES IN GRADED
SHOWER WITH TILED BASE.
· ALL BALCONIES (IF ANY) AND EXTERNAL PAVED AREA TO HAVE A MINIMUM FALL OF 1:100 AWAY FROM DOORS.
· TILE SET OUT:
· AS FAR AS POSSIBLE, SET OUT WORK SO THAT NO TILE LESS THAN HALF SIZE OCCURS.
· ALIGN JOINTS IN FLOOR TILE AT RIGHT ANGLES TO EACH OTHER AND STRAIGHT WITH WALLS TO CONFORM TO
PATTERNS SELECTED.
· GENERALLY SET OUT WALL TILES TO CENTRE LINE OF WALLS IF USING SAME WALL AND FLOOR TIE SIZE OR
GAUGE, SET OUT FLOOR TILES TO RUN IN SAME LINE AS WALL TILES.
· SEAL WITH SILICONE SEALANT TO MATCH GROUT COLOUR TO ALL TILE JUNCTIONS SUCH AS WALL/FLOOR
JUNCTIONS AND JUNCTIONS OF SPLASHBACKS, AND BENCH TOPS ETC.
· SET OUT TO USE ONLY WHOLE TILES WHERE PRACTICAL OR TO GIVE EQUAL MARGINS OF CUT TILE, HALF TILES OR
LARGER.
· WINDOWS AND GLAZING
· REFER TO WINDOW SCHEDULE FOR WINDOW TYPES & SIZES.
· ALL WINDOWS ARE VIEWED EXTERNALLY.
· REFER ELEVATIONS & PLANS FOR SITUATIONS WHERE WINDOW ELEVATIONS ARE MIRRORED.
· CONFIRM ALL DIMENSIONS ON SITE AND NOTIFY THE DESIGNER OF ANY DISCREPANCIES OR CONFLICTS PRIOR TO
FABRICATION AND INSTALLATION.
· ALL GLAZING TO EXTERNAL WINDOWS, EXTERNAL SLIDING DOORS TO BE IN ACCORDANCE WITH AS2047-2014 AND ALL OTHER
GLAZED ASSEMBLIES ARE TO BE IN ACCORDANCE WITH AS1288-2006.
· ALL FULL GLAZED DOORS, SIDELIGHTS, INCLUDING ANY GLAZING CAPABLE OF BEING MISTAKEN FOR A DOORWAY OR OPENING,
SHALL BE CLEARLY MARKED FOR THEIR FULL WIDTH A SOLID NON TRANSPARENT CONTRASTING LINE. THE CONTRASTING LINE
SHALL BE NOT LESS THAN 75MM WIDE AND SHALL EXTEND ACROSS THE FULL WIDTH OF THE GLAZING PANEL. THE LOWER
EDGE OF THE STRIP SHALL BE LOCATED 900MM FROM THE FINISHED FLOOR LEVEL. ANY CONTRASTING LINE ON THE GLAZING
SHALL PROVIDE A MINIMUM OF 30% LUMINANCE CONTRAST WHEN VIEWED AGAINST THE FLOOR SURFACE OR SURFACE
WITHIN 2M OF THE GLAZING ON THE OPPOSITE SIDE.
· ALL FRAMED GLAZING WHERE THE LOWEST SIGHT LINE OF THE GLAZING PANEL IS LESS THAN 500MM FROM THE HIGHEST
ABUTTING FFL MUST BE GRADE A SAFETY GLASS OR ORDINARY ANNEALED GLASS NOT LESS THAN 5MM NOMINAL THICKNESS
PROVIDED THAT THE AREA OF THE GLAZING PANEL IS NOT MORE THAN 1.2M².
· MANUFACTURED OBSCURE GLASS IS TO BE USED WHERE OBSCURE GLAZING IS SHOWN ON DRAWINGS: GLASS TYPE
OBSCURE WHITE GLASS, FLOAT GLASS WITH WHITE OBSCURE INTER LAYER, NO PATTERN. IF REQUESTED, SAMPLE TO BE
PROVIDED TO BUILDING SURVEYOR FOR APPROVAL.
· PROVIDE 125MM MAX OPENING LIMIT TO ALL BEDROOM WINDOWS WITH OVER 2.0M VERTICAL FALL TO OUTSIDE GROUND
SURFACE.
· ALL WINDOWS AND EXTERNAL DOORS TO BE SELECTED POWDERCOAT FINISH ALUMINIUM FRAMES UNLESS OTHERWISE
NOTED.
· ALL WINDOWS GLAZING TO BE IMPROVED ALUMINIUM FRAMES WITH CLEAR GLASS UNLESS NOTED OTHERWISE.
· WINDOW/DOOR SUITES, HARDWARE AND MECHANISMS TO BE INSTALLED ON ACCORDANCE TO MANUFACTURER'S
INSTRUCTIONS AND RECOMMENDATIONS.
· PROVIDE AND INSTALL ALL NECESSARY FLASHING, TRIM, REVEALS AND STILL TRAYS TO MAKE SUITE WEATHERPROOF AND
FINISH TO MATCH ALUMINIUM GLAZING.
· ALLOW FOR ALL HEAD/SILL TRAY FLASHINGS AND COLUMN COVER PLATES ARE REQUIRED. FINISH TO MATCH ALUMINIUM
GLAZED SUITES.
· CHECK ALL NUMBERING AND QUANTITIES AGAINST PLANS AND ELEVATIONS AND NOTIFY THE DESIGNER OF ANY
DISCREPANCIES.
· CHECK ALL SILL LEVELS AGAINST FLOOR LEVELS.
· GLASS SIZES ARE SUGGESTED THICKNESS ONLY. MANUFACTURER TO CONFIRM SIZES ARE IN ACCORDANCE WITH CODE
REQUIREMENTS AND AS1288-2006 PRIOR TO FABRICATION.
· GLAZED SUITES: AS PER PROJECT SPECIFICATION.
· REFER TO PLANS FOR LOCATION AND SWING OF ALL DOORS.
· SUPPLY AND INSTALL EXTERNAL ALUMINIUM DOORS THAT APPEAR IN WINDOW SCHEDULE.
· IF ANY, FIRE RATED DOORS & SMOKE DOORS, FRAMES, CLOSERS, SEALS AND HARDWARE TO SATISFY AUSTRALIAN
STANDARDS AND BCA 2016 REQUIREMENTS.
· WINDOW DIMENSIONS GIVEN REFER TO OPENING DIMENSIONS, FRAME AND GLAZING SIZES TO BE CONFIRMED ON SITE AND
ADJUSTED ACCORDINGLY. DOOR DIMENSIONS AS LABELLED.
· FULL HEIGHT GLAZING THAT COULD BE MISTAKEN AS AN UNOBSTRUCTED OPENING TO BE MARKED WITH AN OPAQUE BAND
NOT LESS THAN 20 MM IN WIDTH AND LOCATED SO THAT THE UPPER EDGE IS NOT LESS THAN 700MM ABOVE THE FLOOR AND
THE LOWER EDGE IS NOT MORE THAN 1.2 M ABOVE THE FLOOR.
· DOOR HARDWARE TO BE NOMINATED BY THE DESIGNER. CLIENT TO CONFIRM.
· TYPICALLY PROVIDE DOOR STOPS AND BUFFERS TO THE APPROVAL OF THE DESIGNER.
· ALL DOOR HANDLES TO BE INSTALLED 1100MM AFL GENERALLY UNLESS OTHERWISE NOTED.
· WATER PROOFING
· WET AREAS ARE TO BE IMPERVIOUS TO WATER I.E. WALL SURFACES AND SUBSTRATES: OF SHOWER ENCLOSURES, OR IF
UNENCLOSED, WITHIN 1.5M HORIZONTALLY FROM THE FIXTURE AND TO A HEIGHT OF 1.8M ABOVE THE FLOOR; AND BEHIND
ANY BATH, BASIN, SINK ETC IF WITHIN 75MM OF A WALL TO A HEIGHT OF 150MM ABOVE THE FIXTURE.
· INSTALL WATER PROOF MEMBRANE STRICTLY IN ACCORDANCE WITH WRITTEN INSTRUCTIONS OF MANUFACTURER. EXECUTE
SEALS AROUND PENETRATIONS, UP-STANDS, ETC. AS INSTRUCTED BY THE MANUFACTURER.
· WET AREAS TO BE IMPERVIOUS TO WATER IN ACCORDANCE WITH AS3740-2010. FLOOR COVERING FOR BATHROOMS, WC AND
LAUNDRY NEEDS TO BE WATER RESISTANT IN ACCORDANCE WITH AS3740-2010.
· IN WET AREAS USE VILLABOARD ONLY OR EQUIVALENT APPROVED TO ALL WET AREA WALL LINING.
· WATERPROOFING MEMBRANES FOR EXTERNAL ABOVE GROUND USE MUST COMPLY WITH AS4654 .1 & 2 - 2012.
· BRICK VENEER- PROVIDE DAMP-PROOF COURSE IN CAVITY WALL CONSTRUCTION BUILT ON CONCRETE SLAB. IN THE BOTTOM
COURSE OF OUTER LEAF, CONTINUOUS HORIZONTALLY ACROSS THE CAVITY AND UP THE INNER FACE BEDDED IN MORTAR,
TURNED 30MM INTO THE INNER LEAF ONE COURSE ABOVE, OR, IN MASONRY VENEER CONSTRUCTION, FASTENED TO THE
INNER FRAME 75MM ABOVE FLOOR LEVEL.
· BALCONIES ARE TO BE STEPPED DOWN FROM THE INTERNAL FINISHED FLOOR LEVEL AND WATERPROOFED USING A TESTED
SYSTEM AND AS PER THE MANUFACTURER'S REQUIREMENTS, TO PREVENT ANY WATER FROM PENETRATING INTO THE
DWELLING. BALCONIES NEED TO BE WATERPROOFED IN ACCORDANCE TO AS4654.1 & 2 -2012.
· THE GROUND BENEATH SUSPENDED FLOORS MUST BE GRADED SO THAT THE AREA BENEATH THE BUILDING IS ABOVE THE
ADJACENT EXTERNAL FINISHED GROUND LEVEL AND SURFACE WATER IS PREVENTED FROM PONDING OR ENTERING UNDER
THE BUILDING.
· BUILDING SEALING:
· THE CHIMNEY OR FLUE OF AN OPEN SOLID-FUEL; BURNING APPLIANCE MUST BE PROVIDED WITH A DAMPER OR FLAP
THAT CAN BE CLOSED TO SEAL THE CHIMNEY OR FLUE;
· A ROOF LIGHT MUST BE SEALED OR CAPABLE OF BEING SEALED, WHEN SERVING A HABITABLE ROOM;
· WINDOWS AND DOORS SERVING A HABITABLE ROOM WINDOW MUST BE FITTED TO EACH EDGE A SEAL TO PREVENT AIR
INFILTRATION;
· EXHAUST FANS SERVING A HABITABLE ROOM MUST BE FITTED WITH A SEALING DEVICE SUCH AS A SELF-CLOSING
DAMPER, FILTER OF THE LIKE;
· ALL ROOF LIGHTS TO HABITABLE ROOM WINDOWS TO BE SEALED OR CAPABLE OF BEING SEALED.
· REFLECTIVE INSULATION INSTALLATION TO COMPLY -
· NECESSARY AIRSPACE TO ACHIEVE REQUIRED R-VALUE, AND
· CLOSELY FITTED AGAINST ANY PENETRATION, DOOR OR WINDOW OPENING, AND
· ADEQUATELY SUPPORTED BY FRAMING MEMBERS, AND
· EACH ADJOINING SHEET OF ROLL MEMBRANE BEING -
· OVERLAPPED NOT LESS THAN 50MM, OR
· TAPED TOGETHER.
To achieve minimum Energy RatingScheme the dwelling will beincorporated with:RAINWATER TANK
EXIS
TING
SEW
ER P
IPE
T
S
PIP
E
PE
GP
EG
PE
G
PE
GP
EG
LOT 740
VACANT
AS OF 25.09.2021
LOT 738
VACANT
AS OF 25.09.2021
LO
T 7
24
VA
CA
NT
AS
O
F2
5.0
9.2
02
1
LO
T 7
23
VA
CA
NT
AS
O
F 2
5.0
9.2
02
1
12.50170°17'30"
28.00260°17'30"
12.50350°17'30"
28.0080°17'30"
100.4
1
0
0
.2
100.0
1
0
0
.
5
0
1
0
0
.
5
2
1
0
0
.
4
5
1
0
0
.
4
9
1
0
0
.
3
7
1
0
0
.
2
8
1
0
0
.
0
1
9
9
.
9
2
1
0
0
.
1
6
1
0
0
.
3
5
1
0
0
.
4
3
1
0
0
.
4
1
1
0
0
.
3
9
1
0
0
.
3
4
1
0
0
.
2
2
1
0
0
.
3
3
1
0
0
.
3
0
1
0
0
.
0
4
9
9
.
8
2
EA
SE
ME
NT
2
.0 m
PE
AR
P
AR
AD
E
TB
M: T
OP
O
F
EL
EC
TR
IC
IT
Y P
IT
RL
1
00
.0
0m
E
HD
EA
SE
ME
NT
2
.0
m
3025
5840
11
50
GARAGE
PORCH
ALFRESCO
2000
LT R
.W.T
.
12
00
4530
5000
GATE
1000
FENCE SETBACK
LOT 739PROPOSED RESIDENCE
COLORBOND ROOF@ 22.5° PITCH TYPICAL
EXPOSED AGGREGATE CONCRETE
500mmLANDSCAPE STRIP
GARAGE SETBACK
HOUSE SETBACK
PORCH SETBACK
SIDE
S
ETBA
CK
SIDE
S
ETBA
CK
REAR SETBACK
RL:100.500
RL:100.400
RL:100.400
RL:100.400
FOOTPATH
NOTATION CONFIRMING CONNECTION TO ALL SANITARY FLUSHING SYSTEM REGARDING 2000-LITRE RAIN WATER
SIDE TIMBER PALING FENCE,CAPPED AND LAPPED WITH125x125mm POST AT A MINIMUM 1.8M HEIGHTPROVIDE TIMBER SLEEPERS AS REQUIRED
NOTE : THE BUILDER MUST COMPLETE ALL FIBRE CABLE ENTRY WORK IN ACCORDANCE WITH OPTICOMM GUIDELINES.
NOTE : ANY TELEVISION ANTENNA MUST BE LOCATED WITHIN THE HOUSE ROOF.
NOTE : DRIVEWAY WIDTH MUST MATCH CROSSOVER WIDTH AT THE TITLE BOUNDARY.
THE WATER TANK MUST BE CONNECTED
TO DOWNPIPES, WITH COLLECTED WATER
TO BE RE-USED FOR GARDEN IRRIGATION
AND TOILET FLUSHING.
TANK.
THE TANK IS PART OF THE BUILD
TIMBER PALING FENCE DETAILS
RESIDENCEGARAGE
AREA SCHEDULE158.71m²36.22m²
17.13sq.3.88sq.
PORCH 05.04m² 0.53sq.
TOTAL 210.00m² 22.60sq.
ALFRESCO 10.03m² 1.06sq.
SITE ANALYSIS
TOTAL COVERED 60.00%SITE COVERAGE 210.00m²/22.60sqSITE AREA 350.00m²
GARDEN AREA : 132.00m² 33.00%PERMEABILITY : 33.00 %
LAWN
LAWN
RETURN TIMBER PALING FENCE,CAPPED EXPOSED POSTS WITH 125x125mm POST AT A MINIMUM 1.8M HEIGHT
NOTE:ANY ADDITIONS, FIXTURES, EQUIPMENT, SHEDS, OUTBUILDINGSOR PERGOLAS MUST BE LOCATED TO THE REAR OF HOUSE OUTOF SIGHT FROM THE STREET OR ANY PUBLIC RESERVE.
MUST CAPTURE RUNOFF FROM AMINIMUM OF 100M2 OF ROOF AREA ANDBE PLUMBED FOR A MINIMUM OF TOILETFLUSHING AND IRRIGATION USES'
SIDE TIMBER PALING FENCE,CAPPED , EXPOSED POSTS 125x125mm POST AT A MINIMUM 1.8M HEIGHTPROVIDE TIMBER SLEEPERS AS REQUIRED
SIDE TIMBER PALING FENCE,CAPPED , EXPOSED POSTS 125x125mm POST AT A MINIMUM 1.8M HEIGHTPROVIDE TIMBER SLEEPERS AS REQUIRED
REAR
TIM
BER
PALI
NG F
ENCE
,CAP
PED
, EXP
OSED
POS
TS
125x
125m
m P
OST
AT
A M
INIM
UM 1
.8M
HEI
GHT
PROV
IDE
TIM
BER
SLEE
PERS
AS
REQU
IRED
THE DOOR TO A FULLY ENCLOSED
SANITARY COMPARTMENT MUST OPEN
OUTWARDS; OR SLIDE; OR BE READILY
REMOVABLE FROM OUTSIDE THE
COMPARTMENT, UNLESS THERE IS A
CLEAR SPACE OF AT LEAST 1.2M BETWEEN
THE CLOSET PAN AND THE DOORWAY.
ALL STORMWATER DRAINS TO CONNECT
TO LEGAL POINT OF DISCHARGE AS
DIRECTED BY LOCAL AUTHORITY.
WEEP HOLES MUST BE CREATED IN THE
COURSE IMMEDIATELY ABOVE ANY DPC OR
FLASHING AT CENTRES NOT EXCEEDING
1.2M EXCEPT WHERE THE HEAD OR SILL
OPENING IS LESS THAN 1.0M.
ARCHITECTURAL DRWGS TO BE
READ IN CONJUNCTION WITH ALL
ASSOCIATED DOCUMENTS &
RELEVANT WORKS INVOLVED.
ARCHITECTURAL DRWGS TO BE
READ IN CONJUNCTION WITH ALL
ASSOCIATED DOCUMENTS &
RELEVANT WORKS INVOLVED.
ALL NEW WINDOWS AND DOORS TO
COMPLY WITH PART 3.6.4.6 BCA. SPECIFY
THE FOLLOWING REQUIREMENTS ON THE
ARCHITECTURAL DRAWINGS:
a. GLASS TO COMPLY WITH AS1288
-2006.
b. IF THE PRESENCE OF GLAZING IN A
DOOR, SIDE PANEL OR PANEL CAPABLE OF
BEING MISTAKEN FOR A DOORWAY OR
OPENING, THE GLASS MUST BE MARKED
TO MAKE IT READILY VISIBLE IN THE FORM
OF AN OPAQUE BAND NOT LESS THAN 20
MM IN HEIGHT LOCATED SO THAT-
(i) THE UPPER EDGE IS NOT LESS THAN
700 MM ABOVE THE FLOOR; AND
(ii) THE LOWER EDGE IS NOT MORE
THAN 1.2 M ABOVE THE FLOOR.
PROVIDE DEMOUNTABLE HINGES ON
WC PROVIDE A 10mm GAP TO WC
DOORS WHERE THERE IS NO
NATURAL VENTILATION
BRICK ARTICULATIONS JOINTS AS
PER AS2870 & AS4773
PROVIDE WATERPROOFING TO WALLS
& FLOORS TO WET AREA AS PER
AS3740
ALL GRADES TO SHOWER WASTE POINTS. ,
THE BATHROOM FLOOR IS REQUIRED TO
BE GRADED TO THE FLOOR WASTE, WITH
GRADE BETWEEN 1:60-1:80, WHERE
LOCATED WITHIN 1500MM OF THE SHOWER
ROSE.
REFER TO ENGINEERS DESIGN DRAWINGS
FOR ALL BEAMS, LINTELS, REINFORCING,
POSTS, COLUMNS, CONCRETE SLABS &
FOOTINGS
BUILDER TO VERIFY ALL DIMENSIONS ON
SITE PRIOR TO THE COMMENCEMENT OF
CONSTRUCTION. ANY DISCREPANCIES TO
BE REPORTED TO THE BUILDING DESIGNER
PRIOR TO SET-OUT FOR RECTIFICATION.
DOWNPIPES MUST NOT BE LOCATED MORE
THAN 12 M APART IN ACCORDANCE WITH
PART 3.5.2.5 OF THE BCA 2019.
DAMP PROOF COURSE. THE HEIGHT OF A
DPC, OR FLASHING SERVING AS A DPC
MUST NOT BE LESS THAN-
(i) 150MM ABOVE THE ADJACENT
GROUND LEVEL; OR
(ii) 75MM ABOVE THE FINISHED
SURFACE LEVEL OF ADJACENT PAVED,
CONCRETED LANDSCAPED AREAS THAT
SLOPE AWAY FROM THE WALL.
ALL WET AREAS ARE TO BE WATER
PROOFED IN ACCORDANCE WITH
AS3740-2010.
ALL GLAZING TO COMPLY WITH
AS1128-2006 & AS2047-2014
PROVIDE GRADE A SAFETY GLAZING FOR
ALL BATHROOMS
NOTE:
BUILDER TO PROVIDE PROVIDE
SUFLOOR VENTS AS PER NCC PART
3.4.1
SITE LEVELS AS WELL AS FIXED FLOOR
LEVELS ARE TO BE CONFIRMED
BUILDER TO VERIFY ALL LEVELS ON SITE
INCLUDING ANY SITE CUT-FILL IF
REQUIRED AND NOTIFY THE BUILDING
DESIGNER PRIOR TO THE
COMMENCEMENT ON ANY BUILDING
WORKS.
Rain water tank and hot watersystem not visible from street
AC unit located belowridge line and at rear of roof
Rain water tank and hot watersystem not visible from street
AC unit located belowridge line and at rear of roof
Rain water tank and hot watersystem not visible from street
RAMP UP
3000
EVES RETURN
PROPOSED SINGLE STOREY DWELLING @LOT 739 PEAR PARADE, FRASER RISE
NOOR SABAH
Project
Sheet No.
Date.
Scale.
Title
Client:
Orientation.
MAY. 2021
* DO NOT SCALE THIS DRAWING.* FIGURED DIMENSIONS TO TAKE PRECEDENCEOVER SCALE. BUILDERS & CONTRACTORS TOVERIFY ALL DIMENSIONS ON SITE PRIOR TOCOMMENCEMENT OF WORKS.
NOTE:SITE & FLOOR LEVELS TO BE CONFIRMED ON SITEBY BUILDER PRIOR TO COMMENCEMENT OF ANYWORKS IF ANY DISCREPANCIES ARE FOUNDCONTACT OFFICE IMMEDIATELY
CONSTRUCTION ISSUEBD_210613
Dwg. No.
REV. No.REVISIONS
PRELIMINARY ISSUE26.07.2021 A
GREENZONE BUILDING DESIGN & THERMAL ASSESSMENT PTY.LTD
ARCHITECTURE DEVELOPMENT BUILDING & PLANNING PERMITS ENERGY RATING SECTION J BUSHFIRE REPORTS RESIDENTIAL COMMERCIAL INDUSTRIAL
E: [email protected] W: WWW.GREENZONE.NET.AU 143 MILITARY ROAD, AVONDALE HEIGHTS VIC 3034 P: 03 9331 0038 M: 0411 325 179
BBUILDING PERMIT ISSUE02.10.2021 B WD-02
SITE PLAN
1:150 @ A3
LETTER BOX
DASHED LINE
POS 25.7M2 BY
MINIMUM 3M DEPTH
POS AREA CALCULATION :
74.4m2 %21.22POS AREA WITH MINIMUM 3M SET BACK 25.7 M2
1450
925
225
1345
To achieve minimum Energy RatingScheme the dwelling will beincorporated with:RAINWATER TANK
20445
470 15960 4015
470240
3400 90 1600 90 10300 240 4015
470240
3400 90 2200 90 2200 7500 90 3925 240
1910 240 4340 9700 90 3925 240
20445470
840 6480 12655240
6000
90
2900
90
1800
90
130090
3000
90
3205
240
240
6000
90
2900
90
1800
90
130090
3000
90
1000
90
2115
240
240
6000
90
1810
90
6650
90
3925
240
1910
240
4340 4250
90
840
90
3500
90
840
90
3925
240
4015
1135
0
4070
1300
5980
240
3570
9016
2090
5500
240
240
2140
9016
0090
1360
9055
0024
0
240
3920
1360
9055
0024
0
240
3920
1360
500
9051
032
0024
0
1135
0
2480
240
3900
9016
1090
1500
240
2480
7670
1200
240
4790
90
410
9010
00
90
3200
240
240
4790
500
9010
00
90
1500
9016
10
240
240
4790
90
410
9010
00
90
3200
240
240
5280
1100
9032
0024
0
5890
900
4520
470
2480
OVERALL
OVERALL L'DRY KITCHEN & FAMILY ALFRESCO
MASTER BED
ALFRESCO
PASSAGE
FAMILY / MEALSKITCHENP'TRY
ENTRY
LOUNGE
PORCH
OVERALL
PORCH
GARAGE BED 3 BATH WIR/ PDR BED 2 ENS'
WIR
MASTER BEDHALLWAYROBE/ BAR
ENTRYPORCH PASSAGE LINEN TV UNIT LINEN
OVER
ALL
GARA
GE
BED
3
HALL
WAY
ROBE
BAR
PASS
AGE
FAM
ILY
/ MEA
LS
PORC
H
PIER
PIER
KITC
HEN
L'DRY
P'TR
Y
LOUN
GE
ENTR
Y
ENTR
Y
OVER
ALL
ENS'
WIR
MAS
TER
BED
ALFR
ESCO
FAM
ILY
/ MEA
LSLI
NEN
HALL
WAY
BED
2
WIR
PDR
BATH
TV U
NIT
AJ
HARD WIRED SMOKE ALARMS TOBE IN ACCORDANCE WITH A.S.3786
EXHAUST FANS TO BE DUCTED TOOUTSIDE AIR
METERBOX
LEGEND
HOT WATER SYSTEM
AND TO BE INTERCONNECTED.
PROVIDE VERTICAL ARTICULATIONJOINTS TO BRICKWORK @ 5000mmMAXIMUM INTERVALS
DG DOUBLE GLAZEDWINDOWS TO HAB. ROOMS
LINE
N
90
ALL SMOKE ALARMS MUST BE INTERCONNECTED AS PERCLAUSE 3.7.2.2. OF THE N.C.C.
A.S.1288-2006 AND A.S.2047.ALL GLAZING TO BE IN ACCORDANCE WITH
ALL W.C. DOORS WITH A CLEARANCELESS THAN 1200mm FROM THE PANTO BE READILY REMOVABLE, SLIDINGOR HINGED OUTWARDS INACCORDANCE WITH PART 3.8.3.3 OFTHE B.C.A. 2019 VOL. 2.
GARAGE EAVE FACING WITHIN 450MMFROM BOUNDARY TO BE PROTECTEDWITH FRL 60/60/60 CONSTRUCTION.PROVIDE A 1/16MM FYRECHECK TO THESIDE FACE BOARD AND UNDERSIDE OFTHE EAVES.
PROVIDE PLIABLE BUILDING MEMBRANE TO
COMPLY WITH AS4200.1 AND TO BE
INSTALLED TO AS4200.2 IN ACCORDANCE
WITH CLAUSE 3.8.7.2 OF THE NCC 2019.
PROVIDE TILES FLOORING TO ALL WET AREA
EXHAUST FAN FLOW RATES MUST BE NOTED AS PER
CLAUSE 3.8.7.3 OF NCC 2019:
A) BATHROOM OR SANITARY COMPARTMENT -25L/S
B) KITCHEN OR LAUNDRY - 40L/S
RESIDENCEGARAGE
AREA SCHEDULE158.71m²36.22m²
17.13sq.3.88sq.
PORCH 05.04m² 0.53sq.
TOTAL 210.00m² 22.60sq.
ALFRESCO 10.03m² 1.06sq.
2.1M
SLID
ING
DOOR
UNI
T
820
820
1200
820
820
820
820 CSD
820
CSD 82
0
820 CSD 820D.
01
D.02
W.0
1/A
W.0
6W
.05
D.04
D.06
D.03 W.02 W.03 W.04
D.05
W.10 W.09 W.08 W.07
W.01/B
470 8401310
NOTE: ALL INTERNAL DOORSTO BE 2340MM HIGH
AJ
AJ
AJ
AJAJ
AJ
AJ
AJ
AJAJ
A
A
RL:100.500
RL:100.400
RL:100.400
RL:100.400
AJAJ
AJ
AJ
AJ
WM
REF.
KITC
HEN
OHC
BENC
H 24
00 x
1000
SLIDING DOOR UNIT
MASTER BED TV
UNI
T
GARAGE
4800
mm
WID
E x 2
400m
m H
IGH
TIM
BER
LOOK
GARA
GE D
OOR
WIT
H RE
MOT
E CO
NTRO
L UN
IT.
PORCH
L'DRY
P'TRYLOUNGE
SHW
'R 1
.2M
ROBE
BATH
1500 FREE STANDING TUB
BED 3 BED 2
PDR
ENS'
SHW
'R 1
.5M
WIR
LINEN TV UNIT LINEN
BARHALLWAY
ALFRESCO
FAMILY & MEALS
ENTRY 3.0m HEIGHT CEILING
WIR 2000
LT R
.W.T
.
2.7m HEIGHT CEILING step100mm
step100mm step
100mm
step
step100mm
PROPOSED SINGLE STOREY DWELLING @LOT 739 PEAR PARADE, FRASER RISE
NOOR SABAH
Project
Sheet No.
Date.
Scale.
Title
Client:
Orientation.
MAY. 2021
* DO NOT SCALE THIS DRAWING.* FIGURED DIMENSIONS TO TAKE PRECEDENCEOVER SCALE. BUILDERS & CONTRACTORS TOVERIFY ALL DIMENSIONS ON SITE PRIOR TOCOMMENCEMENT OF WORKS.
NOTE:SITE & FLOOR LEVELS TO BE CONFIRMED ON SITEBY BUILDER PRIOR TO COMMENCEMENT OF ANYWORKS IF ANY DISCREPANCIES ARE FOUNDCONTACT OFFICE IMMEDIATELY
CONSTRUCTION ISSUEBD_210613
Dwg. No.
REV. No.REVISIONS
PRELIMINARY ISSUE26.07.2021 A
GREENZONE BUILDING DESIGN & THERMAL ASSESSMENT PTY.LTD
ARCHITECTURE DEVELOPMENT BUILDING & PLANNING PERMITS ENERGY RATING SECTION J BUSHFIRE REPORTS RESIDENTIAL COMMERCIAL INDUSTRIAL
E: [email protected] W: WWW.GREENZONE.NET.AU 143 MILITARY ROAD, AVONDALE HEIGHTS VIC 3034 P: 03 9331 0038 M: 0411 325 179
BBUILDING PERMIT ISSUE02.10.2021 B WD-03
GROUND FLOOR PLAN
1:100 @ A3
NOTE: BUILDER TO PROVIDE GAS AND WATER POINT TO ALFRESCO
TIMBER POST
DP DP DP DP
DP
DP
DPDP
DP
DP
SKY LIGHT SKY LIGHT
NOTE: BUILDER TO PROVIDE GAS AND WATER
POINT TO ALFRESCO
To achieve minimum Energy RatingScheme the dwelling will beincorporated with:RAINWATER TANK
T
S
PIP
E
PE
GP
EG
PE
G
PE
GP
EG
LO
T 7
38
VA
CA
NT
AS
O
F 2
2.0
6.2
1
LO
T 7
24
VA
CA
NT
AS
O
F 2
2.0
6.2
1
LO
T 7
23
VA
CA
NT
AS
O
F 2
2.0
6.2
1
12
.5
0
17
0°1
7'3
0"
28.00
260°17'30"
12
.5
0
35
0°1
7'3
0"
28.00
80°17'30"
100.4
1
0
0
.2
100.0
1
0
0
.
5
0
1
0
0
.
5
2
1
0
0
.
4
5
1
0
0
.
4
9
1
0
0
.
3
7
1
0
0
.
2
8
1
0
0
.
0
1
9
9
.
9
2
1
0
0
.
1
6
1
0
0
.
3
5
1
0
0
.
4
3
1
0
0
.
4
1
1
0
0
.
3
9
1
0
0
.
3
4
1
0
0
.
2
2
1
0
0
.
3
3
1
0
0
.
3
0
1
0
0
.
0
4
9
9
.
8
2
EA
SE
ME
NT
2
.0
m
LO
T 7
39
35
0 m
²
TB
M: T
OP
O
F
EL
EC
TR
IC
IT
Y P
IT
RL
1
00
.0
0m
E
EA
SE
ME
NT
2
.5
m
HD
LOT 739PROPOSED RESIDENCE
COLORBOND ROOF@ 22.5° PITCH TYPICAL
3000
LT R
.W.T
.
EVAP.
LOCATION
PROVIDE ROOF VENT
WHIRLYBIRD
PROPOSED SINGLE STOREY DWELLING @LOT 739 PEAR PARADE, FRASER RISE
NOOR SABAH
Project
Sheet No.
Date.
Scale.
Title
Client:
Orientation.
MAY. 2021
* DO NOT SCALE THIS DRAWING.* FIGURED DIMENSIONS TO TAKE PRECEDENCEOVER SCALE. BUILDERS & CONTRACTORS TOVERIFY ALL DIMENSIONS ON SITE PRIOR TOCOMMENCEMENT OF WORKS.
NOTE:SITE & FLOOR LEVELS TO BE CONFIRMED ON SITEBY BUILDER PRIOR TO COMMENCEMENT OF ANYWORKS IF ANY DISCREPANCIES ARE FOUNDCONTACT OFFICE IMMEDIATELY
CONSTRUCTION ISSUEBD_210613
Dwg. No.
REV. No.REVISIONS
PRELIMINARY ISSUE26.07.2021 A
GREENZONE BUILDING DESIGN & THERMAL ASSESSMENT PTY.LTD
ARCHITECTURE DEVELOPMENT BUILDING & PLANNING PERMITS ENERGY RATING SECTION J BUSHFIRE REPORTS RESIDENTIAL COMMERCIAL INDUSTRIAL
E: [email protected] W: WWW.GREENZONE.NET.AU 143 MILITARY ROAD, AVONDALE HEIGHTS VIC 3034 P: 03 9331 0038 M: 0411 325 179
BBUILDING PERMIT ISSUE02.10.2021 B WD-04
ROOF PLAN
1:100 @ A3
DP DP DP DP
DP
DP
DPDP
DP
DP
ALL DOWN PIPES TO BE
CONNECTED TO LPOD ,
SKY LIGHT SKY LIGHT
1200
800
To achieve minimum Energy RatingScheme the dwelling will beincorporated with:RAINWATER TANK
2850
SPOUTING TO SIT ONEXTERNAL GARAGE WALL
GARA
GE
Site
bou
ndar
y
2700
DWEL
LING
2400
Site
bou
ndar
y
WEST ELEVATION SCALE 1:100
TILE FINISH TO PORCH PIERS
4800Wx2400H SECTIONALGARAGE DOOR (REMOTE CONTROLLED)
RENDER FINISH TO BRICKWORK
COLORBOND FASCIA/GUTTER& DOWNPIPES THROUGHOUT
HORIZONTALLY ALIGNED TIMBERSLATS TO PORCH SECTION AS SHOWN.
COLORBOND ROOF@ 22.5° PITCH
TIMBER ENTRY DOOR
2700
DWEL
LING
2400
@ 22.5° PITCH.COLORBOND ROOF
HORIZONTALLY ALIGNED TIMBERSLATS TO HIGHER SECTION AS SHOWN.
FACE BRICKWORKHOLES BELOW FLOOR LEVELCAVITY FLASHING AND WEEP
@ EVERY 4TH PERPEND.
ALL GLAZING WITHIN 500mm OFF FLOOR LEVEL ISTO BE A MINIMUM OF 5mm IN THICKNESS SAFETYGLASS IN ACCORDANCE WITH A.S.1288-2006,
FEATURE TILED FINISH TOBRICK PIER (PORCH)
SOUTH ELEVATION SCALE 1:100
24002700
resi
denc
e
wind
ow h
ead
heig
ht
RENDER FINISH TOALFRESCO PIER
ALL GLAZING WITHIN 500mm OFF FLOOR LEVEL ISTO BE A MINIMUM OF 5mm IN THICKNESS SAFETYGLASS IN ACCORDANCE WITH A.S.1288-2006,
FACE BRICKWORK
COLORBOND FASCIA/GUTTER& DOWNPIPES THROUGHOUT@ 22.5° PITCH.
COLORBOND ROOF
HOLES BELOW FLOOR LEVELCAVITY FLASHING AND WEEP
@ EVERY 4TH PERPEND.
EAST ELEVATIONSCALE 1:100
2400 27
00re
side
nce
wind
ow h
ead
heig
ht
@ 22.5° PITCH.COLORBOND ROOF
STACKER DOOR UNIT SLIDING DOOR UNITHOLES BELOW FLOOR LEVELCAVITY FLASHING AND WEEP
@ EVERY 4TH PERPEND.
ALL GLAZING WITHIN 500mm OFF FLOOR LEVEL ISTO BE A MINIMUM OF 5mm IN THICKNESS SAFETYGLASS IN ACCORDANCE WITH A.S.1288-2006,
HORIZONTALLY ALIGNED TIMBERSLATS TO HIGHER SECTION AS SHOWN.
ALL WINDOWS & DOORS @ 2400mmHEAD HEIGHT UNLESS OTHERWISE NOTED
COLORBOND FASCIA/GUTTER& DOWNPIPES THROUGHOUT
NORTH ELEVATION
100.34
100.22
100.33
100.30
100.04
99.82
100.01
100.28
100.37
100.49
100.45
100.52
100.20
100.28
R
E
S
C
O
D
E
S
E
T
B
A
C
K
R
E
S
C
O
D
E
S
E
T
B
A
C
K
100.52
100.34
100.50
100.39
R
E
S
C
O
D
E
S
E
T
B
A
C
K
Site
bou
ndar
y
R
E
S
C
O
D
E
S
E
T
B
A
C
K
COLORBOND FASCIA/GUTTER& DOWNPIPES THROUGHOUT
ALL WINDOWS & DOORS @ 2400mmHEAD HEIGHT UNLESS OTHERWISE NOTED
EVAP.
LOCATION
D.01W.01/A
W.06 W.05 D.04D.06
D.03
W.02
W.03W.04D.05
W.10 W.09 W.08 W.07
W.01/A
Site
bou
ndar
y
SCALE 1:100
PROPOSED SINGLE STOREY DWELLING @LOT 739 PEAR PARADE, FRASER RISE
NOOR SABAH
Project
Sheet No.
Date.
Scale.
Title
Client:
Orientation.
MAY. 2021
* DO NOT SCALE THIS DRAWING.* FIGURED DIMENSIONS TO TAKE PRECEDENCEOVER SCALE. BUILDERS & CONTRACTORS TOVERIFY ALL DIMENSIONS ON SITE PRIOR TOCOMMENCEMENT OF WORKS.
NOTE:SITE & FLOOR LEVELS TO BE CONFIRMED ON SITEBY BUILDER PRIOR TO COMMENCEMENT OF ANYWORKS IF ANY DISCREPANCIES ARE FOUNDCONTACT OFFICE IMMEDIATELY
CONSTRUCTION ISSUEBD_210613
Dwg. No.
REV. No.REVISIONS
PRELIMINARY ISSUE26.07.2021 A
GREENZONE BUILDING DESIGN & THERMAL ASSESSMENT PTY.LTD
ARCHITECTURE DEVELOPMENT BUILDING & PLANNING PERMITS ENERGY RATING SECTION J BUSHFIRE REPORTS RESIDENTIAL COMMERCIAL INDUSTRIAL
E: [email protected] W: WWW.GREENZONE.NET.AU 143 MILITARY ROAD, AVONDALE HEIGHTS VIC 3034 P: 03 9331 0038 M: 0411 325 179
BBUILDING PERMIT ISSUE02.10.2021 B WD-05
ELEVATIONS
1:100 @ A3
100.500
3310
4749
3355
100.500
2952
5044
2800
100.500
4334 51
68
300035
67
5000
3030
2960
2978
AVG
.
100.500
3577
5000
EVAP.
LOCATION
EVAP.
LOCATION
GARAGE EAVE FACING WITHIN 450MM FROMBOUNDARY TO BE PROTECTED WITH FRL60/60/60 CONSTRUCTION.PROVIDE A 1/16MM FYRECHECK TO THE SIDEFACE BOARD AND UNDERSIDE OF THE EAVES.
UNDER ROOF COLORBOND SHEETING
SKY LIGHT SKY LIGHT
To achieve minimum Energy RatingScheme the dwelling will beincorporated with:RAINWATER TANK
SECTION A-A
REFER TO ENERGY RATING REPORT FORCEILING INSULATION REQUIREMENTS.
ROOF TRUSSES @900mm MAXIMUM CTRS.AS PER MANUFACTURER'S SPECIFICATIONS.
REFER TO ENERGY RATING REPORT FORWALL INSULATION REQUIREMENTS.
2700
Resi
denc
e
@ 22.5° PITCH
OVER 1 METRE.FROM PERIMETER FOOTINGS 1:25EXTERNAL SURFACE TO GRADE AWAY
COLORBOND ROOF
FAMILY & MEALS HALL
OVER 1 METRE.FROM PERIMETER FOOTINGS 1:25EXTERNAL SURFACE TO GRADE AWAY REFER TO ENGINEER'S DESIGN AND
SPECIFICATIONS FOR CONCRETEWAFFLE SLAB DETAILS
BATH
LINE
N
MASONRY
PROPOSED SINGLE STOREY DWELLING @LOT 739 PEAR PARADE, FRASER RISE
NOOR SABAH
Project
Sheet No.
Date.
Scale.
Title
Client:
Orientation.
MAY. 2021
* DO NOT SCALE THIS DRAWING.* FIGURED DIMENSIONS TO TAKE PRECEDENCEOVER SCALE. BUILDERS & CONTRACTORS TOVERIFY ALL DIMENSIONS ON SITE PRIOR TOCOMMENCEMENT OF WORKS.
NOTE:SITE & FLOOR LEVELS TO BE CONFIRMED ON SITEBY BUILDER PRIOR TO COMMENCEMENT OF ANYWORKS IF ANY DISCREPANCIES ARE FOUNDCONTACT OFFICE IMMEDIATELY
CONSTRUCTION ISSUEBD_210613
Dwg. No.
REV. No.REVISIONS
PRELIMINARY ISSUE26.07.2021 A
GREENZONE BUILDING DESIGN & THERMAL ASSESSMENT PTY.LTD
ARCHITECTURE DEVELOPMENT BUILDING & PLANNING PERMITS ENERGY RATING SECTION J BUSHFIRE REPORTS RESIDENTIAL COMMERCIAL INDUSTRIAL
E: [email protected] W: WWW.GREENZONE.NET.AU 143 MILITARY ROAD, AVONDALE HEIGHTS VIC 3034 P: 03 9331 0038 M: 0411 325 179
BBUILDING PERMIT ISSUE02.10.2021 B WD-06
SECTIONAL DETAILS
1:100 @ A3
SCALE 1:100
GENERAL FRAMING MEMBERS (U.N.O.)
STUDSUPPER STOREYS: 90x35 MGP10 @ 450 MAX. CTRS.
NOTCHED 20mm FOR BRACING(MAX. HEIGHT 2700mm)90x45 MGP10 @ 450 MAX. CTRS.(HEIGHT 2700mm-3000mm)
LOWER STOREYS: 90x35 MGP10 @ 450 MAX. CTRS.NOTCHED 20mm FOR BRACING(MAX. HEIGHT 2700mm)90x45 MGP10 @ 450 MAX. CTRS.(HEIGHT 2700mm-3000mm)90x45 F17 KD HW @ 450 MAX. CTRS.(MAX. HEIGHT 3700mm)
DOUBLE STUDS: 2/90x45 MGP10 STUDS
FIX END STUD WALL TO MASONRY WALLS WITH M10DYNABOLT AT TOP, BOTTOM AND 1500 MAX. CTRS. (TYP.)
WALL PLATESUPPER STOREYS: TOP PLATE - 45x90 MGP10 NOT TRENCHED
BOTTOM PLATE- 45x90 MGP10 NOT TRENCHED
LOWER STOREYS: TOP PLATE - 2/45x90 MGP10 NOT TRENCHEDBOTTOM PLATE- 45x90 MGP10 NOT TRENCHED
PROVIDE DOUBLE TOP PLATES IF SUPPORTING TILED ROOF TRUSS
STUDS AT SIDE OPENINGSOPENING WIDTH: STUDS:
UP TO 1200mm 1/90x45 MGP101200mm - 1800mm 2/90x45 MGP101800mm - 2400mm 2/90x45 MGP10
WALL BRACINGBRACING OF ALL STUD WALLS TO BE IN ACCORDANCE WITH THERESIDENTIAL TIMBER FRAMING CONSTRUCTION A.S.1684.2-2006U.N.O.
FIXING REQUIREMENTSGENERAL: REFER TO A.S.1684.2-2006 RESIDENTIAL TIMBER
FRAMING CONSTRUCTION MANUAL TYPICAL FIXINGREQUIREMENTS.
GENERAL: EQUIVILENT TIMBER GRADE CAN BE USED TO REPLACETIMBER GRADES SPECIFIED.
SELECTED ARCHITRAVEMAX. 1.2m CRS.
FLASHING TURNED
WALL STUD(S)
PLASTERBOARDLINING
BOTTOM PLATE
EXTERNALBRICKFACE
SCALE 1:20STANDARD WAFFLE SLAB DETAIL
UP MIN.150mm
WEEPHOLES @
COMBINED D.P.C.AND FLASHING
0.2mm BRANDEDPLASTIC MEMBRANE
WAFFLE SLAB AS PERENGINEER'S DRAWINGS
SLOPE ADJACENT GROUNDAWAY FROM FOOTINGS
WATER BARRIER SARKING (DPC)DRAINS TO HEAD FLASHING
HEAD FLASHING
CALKING TO PREVENT AIR LEAKAGE
BACKING ROD
WEATHER STRIPPING
RAIN SEAL
BACKING ROD
CALKING TO PREVENT AIR LEAKAGE
WATER BARRIER SARKING (DPC)
FLASHING DRAIN TOEXTERIOR WEEP HOLE
WEEP HOLE
LINTEL
REVEAL
SILL
WEEP HOLE
INSULATION
TYPICAL WINDOW FLASHING DETAILSCALE 1:20
10
ARTICULATION JOINT DETAILSCALE 1:10
GAP FORMED BYREMOVABLE SPACER
MASONRYFLEXIBLE ANCHOR
TUBULAR POLYTHENE FOAMBACKING INSTALLED IN OPENJOINT LEFT BY BRICKLAYER
MASTIC SEALANT
TO TRUSS CONNCENCTION DETAILSCALE 1:20
STANDARD INTERNAL STUD WALL
PROVIDE 30mm SPACEBETWEEN BOTTOM TRUSSAND PLATE OF WALL
CORNICE
TOP PLATE
PLASTERBOARD
GALVANIZED PATENTSLOTTED BRACKETOF TRUSS
BOTTOM CHORD
CEILING BATTEN
EXTERNAL WALL FINISHFACE BRICKWORK
COLORBOND FASCIAAND SPOUTING
METAL FLASHING
BOUN
DARY
P/BOARD CORNICE
GARAGE
PER MANUFACTURERS SPECIFICATIONS.ROOF TRUSSES @ 900MM MAX. CTS. AS
GARAGE BOUNDARY SPOUTING DETAILSCALE 1:20
THROUGHOUT
SHEET ROOFING@ 22.5° PITCH
SISALATION FIXED TOEXTERNAL FACE OFSTUDS
TRUSS ROOF TOMANUFACTURERSPECIFICATION
PLASTERBOARDLINING
TOP PLATE
CEMENT SHEETINGFASCIA BOARD
COLORBOND GUTTER
QUADFACE BRICK WORK
DETAIL OF RESIDENCE SPOUTING SCALE 1:20
DEGREES PITCHSHEET ROOFING AT 22.5
TRUSSES @ MAX. 900 CTS
STUD WALL
RESIDENCEFACE BRICKWORK
FASCIA THROUGHOUTCOLOURBOND SPOUTING AND
P/BOARD CORNICE
SCALE 1:20RESIDENCE SPOUTING DETAIL
PER MANUFACTURERS SPECIFICATIONS.ROOF TRUSSES @ 900MM MAX. CTS. AS
SHEET ROOFING@ 22.5° PITCH
To achieve minimum Energy RatingScheme the dwelling will beincorporated with:RAINWATER TANK
TWIN
FLU
ORES
CENT
LIG
HT
TWIN
FLU
ORES
CENT
LIG
HT
x
x
x
SCALE 1:100ARTIFICIAL LIGHTING LOAD LAYOUT
P
P
P
ARTIFICIAL LIGHT CALCULATIONS
RESIDENCE (5W/m²) GROUND F.
GARAGE (3W/m²)
9
9
40
PER UNIT QTY.WATTS
WATTSTOTAL
41
80W
72W
414W
PERMITTEDMAX. WATTS
108.66W
60.28W
793.55 W
AREA
15.07m²3
36.22m² 2
158.71m²
WATTS
80W
369W
27W
15 3 45W
OUTDOOR AREA (4W/m²)PORCH & ALFRESCO
BATTEN 9W
DOWNLIGHT 9W
LEGEND
x EXTERNAL WALLMOUNTED LIGHT 15W
TWIN FLUORESCENTLIGHT 40W
TWIN FLUORESCENT LIGHT
P PENDANT LIGHT 15W
15 3 45W
ARTIFICIAL LIGHTING TO COMPLY WITH 3.12.5.5ARTIFICIAL LIGHTING FROM THE B.C.A. (NCC) 2011
NOTES
HEAT LAMPS EXEMPT.
ARTIFICIAL LIGHTING AROUND PERIMETER OF AA BUILDING MUST:i) BE CONTROLLED BY A DAYLIGHT CENSOR; ORii) HAVE AN AVERAGE LIGHT SOURCE EFFICIENCYOF NOT LESS THAN 40 LUMENS/W
RESIDENCEGARAGE
AREA SCHEDULE158.71m²36.22m²
17.13sq.3.88sq.
PORCH 05.04m² 0.53sq.
TOTAL 210.00m² 22.60sq.
ALFRESCO 10.03m² 1.06sq.
W
M
REF.
KITC
HEN
OHC
BENC
H 24
00 x
1000
SLIDING DOOR UNIT
MASTER BED TV
UNI
T
GARAGE
4800
mm
WID
E x 2
400m
m H
IGH
TIM
BER
LOOK
GARA
GE D
OOR
WIT
H RE
MOT
E CO
NTRO
L UN
IT.
PORCH
L'DRY
P'TRYLOUNGE
SHW
'R 1
.2M
ROBE
BATH
1500 FREE STANDING TUB
BED 3 BED 2
PDR
ENS'
SHW
'R 1
.5M
WIR
LINEN TV UNIT LINEN
BARHALLWAY
ALFRESCO
FAMILY & MEALS
ENTRY 3.0m HEIGHT CEILING
WIR 2000
LT R
.W.T
.
2.7m HEIGHT CEILING
PROPOSED SINGLE STOREY DWELLING @LOT 739 PEAR PARADE, FRASER RISE
NOOR SABAH
Project
Sheet No.
Date.
Scale.
Title
Client:
Orientation.
MAY. 2021
* DO NOT SCALE THIS DRAWING.* FIGURED DIMENSIONS TO TAKE PRECEDENCEOVER SCALE. BUILDERS & CONTRACTORS TOVERIFY ALL DIMENSIONS ON SITE PRIOR TOCOMMENCEMENT OF WORKS.
NOTE:SITE & FLOOR LEVELS TO BE CONFIRMED ON SITEBY BUILDER PRIOR TO COMMENCEMENT OF ANYWORKS IF ANY DISCREPANCIES ARE FOUNDCONTACT OFFICE IMMEDIATELY
CONSTRUCTION ISSUEBD_210613
Dwg. No.
REV. No.REVISIONS
PRELIMINARY ISSUE26.07.2021 A
GREENZONE BUILDING DESIGN & THERMAL ASSESSMENT PTY.LTD
ARCHITECTURE DEVELOPMENT BUILDING & PLANNING PERMITS ENERGY RATING SECTION J BUSHFIRE REPORTS RESIDENTIAL COMMERCIAL INDUSTRIAL
E: [email protected] W: WWW.GREENZONE.NET.AU 143 MILITARY ROAD, AVONDALE HEIGHTS VIC 3034 P: 03 9331 0038 M: 0411 325 179
BBUILDING PERMIT ISSUE02.10.2021 B WD-07
LIGHTING LAYOUT
1:100 @ A3
TYPICAL WATER PROOF / SHOWER DRAINAGE DETAILS
To achieve minimum Energy RatingScheme the dwelling will beincorporated with:RAINWATER TANK
2700
RESI
DENC
E
2400
WIN
DOW
H. H
EIGH
T
GROUND FLOOR
CEILING LEVEL
WINDOWSGROUND FLOORSCALE 1:100
2400
3000
W.01/A
2700
RESI
DENC
E
2400
WIN
DOW
H. H
EIGH
T
GROUND FLOOR
CEILING LEVEL
DOORSGROUND FLOORSCALE 1:100
4800
2400
D.01SECTIONAL GARAGE DOOR
1200
2400
D.02 ENTRY DOOR
1200
W.01/B
700
1000
700
W.03
2100
300
3000
W.02
600
W.05
600
W.06 W.07
1200
1200
900
W.08
1800
600
1800
W.09
1200
1200
1500
W.10
1800
600
1800
1500
2400
D.03L'DRY SLIDING DOOR
2100
2400
D.04SLIDING DOOR UNIT
3000
2400
D.05 MASTER BED STACKER DOOR
2700
RESI
DENC
E
2400
WIN
DOW
H. H
EIGH
T
GROUND FLOOR
CEILING LEVEL
WINDOWSGROUND FLOORSCALE 1:100
820
2400
D.06 REAR EXTERNAL DOOR
W.04
2100
300
AWNING CORNER WINDOW FIXED CORNER WINDOW SLIDING WINDOW SLIDING WINDOW SLIDING WINDOW
800
800
800
800
800
800
600 6001800
SLIDING WINDOW SLIDING WINDOW AWNING WINDOW AWNING WINDOW
SLIDING WINDOW SLIDING WINDOW
600 600
2400
2400
NOTE:ALL BEDROOM WINDOWS ON A FIRST FLOOR OR ABOVE HAVE ANY OPENABLEPORTION OF THE WINDOW ABOVE 1.7m ABOVE F.F.L TO PROVIDE PROTECTION TOTHE OPENING AS PER N.C.C 3.9.2.5 PROTECTION OF OPENING TO BE ARESTRICTED OPENING OF 125mm.
GLAZING LEGEND F : FIXED GLASSAW : AWNING WINDOWSD : SLIDING DOOROP: OPAQUE GLAZING
NOTEALL WINDOWS TO BE SITE MEASURED AND CHECKED TO ENSURE FIT IN THE FRAME.
GENERAL GLAZING NOTES :· ALL GLAZING MUST COMPLY WITH AS.1288 -2006 AND AS2047-2014.· REFER TO ENERGY RATING REPORT FOR MORE DETAILS ABOUT GLAZING SPECIFICATIONS.· BEDROOM WINDOWS ON A FIRST FLOOR OR ABOVE MUST HAVE ANY OPENABLE PORTION OF THE WINDOW ABOVE 1.7m ABOVE F.F.L OR PROVIDE PROTECTION TO THE OPENING AS PER N.C.C 3.9.2.5 PROTECTION OF OPENING TO
BE A RESTRICTED OPENING OF 125mm.· PROVIDE GRADE A SAFETY GLASS TO ALL BATHROOM WINDOWS.· WINDOW MEASUREMENTS INDICATED MAY VARY FROM MANUFACTURED SIZES. BUILDER TO PLACE ORDER WITH WINDOW MANUFACTURER WITH STANDARD SIZES THAT MATCH THE ABOVE MEASUREMENTS WITHIN CLOSE
PROXIMITY BUILDER TO CONFIRM WINDOW HEAD HEIGHTS DO NOT CONFLICT WITH EAVE DETAILS PRIOR TO ORDERING ROOF STRUCTURE WINDOW SIZES TO BE VERIFIED ON SITE PRIOR TO PLACING ORDER WITH MANUFACTURER· ALL FRAMED GLAZING WHERE THE LOWEST SIGHT LINE OF THE GLAZING PANEL IS LESS THAN 500MM FROM THE HIGHEST ABUTTING FFL MUST BE GRADE A SAFETY GLASS OR ORDINARY ANNEALED GLASS NOT LESS THAN 5MM
NOMINAL THICKNESS PROVIDED THAT THE AREA OF THE GLAZING PANEL IS NOT MORE THAN 1.2M².· ALL FULL GLAZED DOORS, SIDELIGHTS, INCLUDING ANY GLAZING CAPABLE OF BEING MISTAKEN FOR A DOORWAY OR OPENING, SHALL BE CLEARLY MARKED FOR THEIR FULL WIDTH A SOLID NON TRANSPARENT CONTRASTING
LINE. THE CONTRASTING LINE SHALL BE NOT LESS THAN 75MM WIDE AND SHALL EXTEND ACROSS THE FULL WIDTH OF THE GLAZING PANEL. THE LOWER EDGE OF THE STRIP SHALL BE LOCATED 900MM FROM THE FINISHED FLOORLEVEL. ANY CONTRASTING LINE ON THE GLAZING SHALL PROVIDE A MINIMUM OF 30% LUMINANCE CONTRAST WHEN VIEWED AGAINST THE FLOOR SURFACE OR SURFACE WITHIN 2M OF THE GLAZING ON THE OPPOSITE SIDE.
· BUILDER TO CONFIRM WINDOWS DIMENSIONS ON SITE PRIOR ANY MANUFACTURER ORDERING.
AW
AW AW AW
S SS S
S S
SS
SD SD SD SD
F
F
F
F F
F
F F
F
F
FF
FF F F
F
F F
F F
F
F F
F
F F F
OP
OP
PROPOSED SINGLE STOREY DWELLING @LOT 739 PEAR PARADE, FRASER RISE
NOOR SABAH
Project
Sheet No.
Date.
Scale.
Title
Client:
Orientation.
MAY. 2021
* DO NOT SCALE THIS DRAWING.* FIGURED DIMENSIONS TO TAKE PRECEDENCEOVER SCALE. BUILDERS & CONTRACTORS TOVERIFY ALL DIMENSIONS ON SITE PRIOR TOCOMMENCEMENT OF WORKS.
NOTE:SITE & FLOOR LEVELS TO BE CONFIRMED ON SITEBY BUILDER PRIOR TO COMMENCEMENT OF ANYWORKS IF ANY DISCREPANCIES ARE FOUNDCONTACT OFFICE IMMEDIATELY
CONSTRUCTION ISSUEBD_210613
Dwg. No.
REV. No.REVISIONS
PRELIMINARY ISSUE26.07.2021 A
GREENZONE BUILDING DESIGN & THERMAL ASSESSMENT PTY.LTD
ARCHITECTURE DEVELOPMENT BUILDING & PLANNING PERMITS ENERGY RATING SECTION J BUSHFIRE REPORTS RESIDENTIAL COMMERCIAL INDUSTRIAL
E: [email protected] W: WWW.GREENZONE.NET.AU 143 MILITARY ROAD, AVONDALE HEIGHTS VIC 3034 P: 03 9331 0038 M: 0411 325 179
BBUILDING PERMIT ISSUE02.10.2021 B WD-08
WINDOW SCHEDULE
1:100 @ A3
GENERAL ENERGY RATING NOTES :REFER TO ENERGY RATING REPORT DONE BY GREEN ZONE PTY. LTD.:
GROUND FLOOR - WAFFLE CONCRETE SLAB - NO INSULATIONALL EXTERNAL WALLS - R2.5 INSULATION BATTS + SISALATION.INTERNAL WALLS TO GARAGE - R2.5 INSULATION BATTS.INTERNAL WALLS TO BATH, LDRY & PDR - R2.5 INSULATION BATTS.METAL ROOF - R5.0 INSULATION BATTS LAID DIRECTLY ABOVE CEILING.
ALL FIXED WINDOWS & SLIDING DOORS_DOUBLE GLAZING _ ALUMINIUM FRAME.MINIMUM OVERALL U FACTOR VALUE OF U 4.30MINIMUM SHADING COEFFICIENT OF SHGC 0.53
ALL REMAINING WINDOWS_DOUBLE GLAZING _ ALUMINIUM FRAME.MINIMUM OVERALL U FACTOR VALUE OF U 4.30MINIMUM SHADING COEFFICIENT OF SHGC 0.47
2100 2100
To achieve minimum Energy RatingScheme the dwelling will beincorporated with:RAINWATER TANK
EXIS
TING
SEW
ER P
IPE
T
S
PIP
E
PE
GP
EG
PE
G
PE
GP
EG
LOT 740
VACANT
AS OF 25.09.2021
LOT 738
VACANT
AS OF 25.09.2021
LO
T 7
24
VA
CA
NT
AS
O
F2
5.0
9.2
02
1
LO
T 7
23
VA
CA
NT
AS
O
F 2
5.0
9.2
02
1
12.50170°17'30"
28.00260°17'30"
12.50350°17'30"
28.0080°17'30"
100.4
1
0
0
.2
100.0
1
0
0
.
5
0
1
0
0
.
5
2
1
0
0
.
4
5
1
0
0
.
4
9
1
0
0
.
3
7
1
0
0
.
2
8
1
0
0
.
0
1
9
9
.
9
2
1
0
0
.
1
6
1
0
0
.
3
5
1
0
0
.
4
3
1
0
0
.
4
1
1
0
0
.
3
9
1
0
0
.
3
4
1
0
0
.
2
2
1
0
0
.
3
3
1
0
0
.
3
0
1
0
0
.
0
4
9
9
.
8
2
EA
SE
ME
NT
2
.0 m
PE
AR
P
AR
AD
E
TB
M: T
OP
O
F
EL
EC
TR
IC
IT
Y P
IT
RL
1
00
.0
0m
E
HD
EA
SE
ME
NT
2
.0
m
GATE
LOT 739PROPOSED RESIDENCE
500mmLANDSCAPE STRIP
FOOTPATH
LAWN
RAMP UP
PROPOSED SINGLE STOREY DWELLING @LOT 739 PEAR PARADE, FRASER RISE
NOOR SABAH
Project
Sheet No.
Date.
Scale.
Title
Client:
Orientation.
MAY. 2021
* DO NOT SCALE THIS DRAWING.* FIGURED DIMENSIONS TO TAKE PRECEDENCEOVER SCALE. BUILDERS & CONTRACTORS TOVERIFY ALL DIMENSIONS ON SITE PRIOR TOCOMMENCEMENT OF WORKS.
NOTE:SITE & FLOOR LEVELS TO BE CONFIRMED ON SITEBY BUILDER PRIOR TO COMMENCEMENT OF ANYWORKS IF ANY DISCREPANCIES ARE FOUNDCONTACT OFFICE IMMEDIATELY
CONSTRUCTION ISSUEBD_210613
Dwg. No.
REV. No.REVISIONS
PRELIMINARY ISSUE26.07.2021 A
GREENZONE BUILDING DESIGN & THERMAL ASSESSMENT PTY.LTD
ARCHITECTURE DEVELOPMENT BUILDING & PLANNING PERMITS ENERGY RATING SECTION J BUSHFIRE REPORTS RESIDENTIAL COMMERCIAL INDUSTRIAL
E: [email protected] W: WWW.GREENZONE.NET.AU 143 MILITARY ROAD, AVONDALE HEIGHTS VIC 3034 P: 03 9331 0038 M: 0411 325 179
BBUILDING PERMIT ISSUE02.10.2021 B WD-09
LANDSCAPE PLAN
1:150 @ A3
LANDSCAPE SCHEDULE:
ACACIA ACINACEA
CALLISTEMON SALIGNUS
PROPOSED CONCRETE
PROPOSED LAWN
LANDSCAPESCHEDULE:
FRONTAGE: 12.5 M
FRONT AREA: 64M
HARDSCAPE : 23M 36%
SOFTSCAPE : 41M 64%
AT LEAST 3 PLANTS PER SQUAREMETER MUST BE PROVIDED TOMULCHED GARDEN BED AREAS.
LANDSCAPE BY BUILDERLETTER BOX
EXPOSED AGGREGATE CONCRETE
50
0
LAWN
LAWN
To achieve minimum Energy RatingScheme the dwelling will beincorporated with:RAINWATER TANK