Construction Assignment 1 Panel

5
FACADE SECTION FRONT SCALE 1 : 20 FACADE SECTION BACK SCALE 1 : 20 N EXTERIOR SECTION DETAIL B-B SCALE 1 : 5 1 2 3 4 5 6 7 8 9 ETAIL A-A DETAIL B-B 1 4 5 4 1 2 4 5 10 1 Aluminium Profile 2 Aluminium 3 Insulation 4 Metal Cladding 5 In-situ Concrete 6 Weathering Profile 7 Ventilation 8 Sealant 9 Closed Cell Insulation LEGEND 10 Float Glass WINDOW SECTION DETAIL A-A SCALE 1 : 5 derick uong zicci zi ramada shayman precedent - details agora theatre - UN studio

Transcript of Construction Assignment 1 Panel

Page 1: Construction Assignment 1 Panel

FACADE SECTION FRONTSCALE 1 : 20

FACADE SECTION BACKSCALE 1 : 20

N

EXTERIOR SECTIONDETAIL B-BSCALE 1 : 5

1

2

3

4

5

6

7

8 9

DETAIL A-A

DETAIL B-B

1 4 5

4

2

1

2

4

5

10

1 Aluminium Pro�le

2 Aluminium

3 Insulation

4 Metal Cladding

5 In-situ Concrete

6 Weathering Pro�le

7 Ventilation

8 Sealant

9 Closed Cell Insulation

LEGEND

10 Float Glass

WINDOW SECTIONDETAIL A-ASCALE 1 : 5

derick uongzicci ziramada shayman

precedent - detailsagora theatre - UN studio

Page 2: Construction Assignment 1 Panel

derick uongzicci ziramada shayman

faca

dem

ain

stru

ctur

esu

bstr

uctu

reco

lum

ns d

istr

ibut

ion

steel panel cladding

steel structure

steel sub structure

�oor slab and columns distribution

precedent - axonometricagora theatre - UN studio

Page 3: Construction Assignment 1 Panel

derick uongzicci ziramada shayman

1 2 3 4

5 6 7 8

combining x and z scale

scale in one direction

site characteristic

we will try to put the building on the hill (Beverly area) in LA, which is subject to earthquake. Weather: not so much rain during the year, mostly dry and hot.

So our �rst priority for structural changes are:- stretch in x direction: to give abilities to have outlook beyond the hills.- stretch in z direction: could be pushed down, could be dragged up to give more view- stronger base, stronger structure- material changes: could possibly turn from steel to timber, lighter and more enviromental friendly

agora theatre - UN Studiovariation

Page 4: Construction Assignment 1 Panel

derick uongzicci ziramada shayman

faca

dem

ain

stru

ctur

esu

bstr

uctu

reco

lum

ns d

istr

ibut

ion

timber cladding

steel structure

timber structure

SCALE = 1:500

outcome - axonometricagora theatre - UN studio

Page 5: Construction Assignment 1 Panel

derick uongzicci ziramada shayman

outcome - detailsagora theatre - UN studio

WINDOW SECTIONDETAIL C-CSCALE 1 : 2

External frame cladding to jambs/head

Casement beading

Beading support clips

External weatherseal

Secondary weatherseal

External glazing gasket

Internal glazing seal

Glass

External frame upper cladding to cill

External frame lower cladding to cill

1

2

4

3

5

6

7

8

9

10

11

Timber members

IINNSSIIDDEE

4

4

4

4

3

3

7

5

6

6

5

7

8

9

9

10

11

1

2

2

8

HEAD

JAMB

CILL

TIMBER CLADDING DETAILSCALE 1 : 2

12

13

14

15

16

17

18

19

12 Timber cladding

13 Vertical batten

14 Nail as speci�ed

15 Breather membrane

16 Timber frame

19 Cavity insulation

17 Mechanical fastener

18 Concrete slab