![Page 1: Considerations for Accurate Measurement and … Solids Reduction (VSR): Considerations for Accurate Measurement and Reporting Martyn Quinn Eastern Region Biosolids Coordinator 329-3505](https://reader031.fdocuments.in/reader031/viewer/2022030501/5aad4b187f8b9aa06a8e1edb/html5/thumbnails/1.jpg)
Volatile Solids Reduction (VSR):Volatile Solids Reduction (VSR):
Considerations for AccurateConsiderations for Accurate Measurement and Reporting Measurement and Reporting
Martyn QuinnEastern Region Biosolids Coordinator
September, 2009
![Page 2: Considerations for Accurate Measurement and … Solids Reduction (VSR): Considerations for Accurate Measurement and Reporting Martyn Quinn Eastern Region Biosolids Coordinator 329-3505](https://reader031.fdocuments.in/reader031/viewer/2022030501/5aad4b187f8b9aa06a8e1edb/html5/thumbnails/2.jpg)
What are volatile solids?What are volatile solids?
Volatile solids are the portion of total solidspresent in sludge that contain calorific value.
They are organic compounds of plant or animalorigin.
They can be removed or reduced throughbiological processes.
Total solids consists of volatile and fixed solids(such as silt, gravel).
![Page 3: Considerations for Accurate Measurement and … Solids Reduction (VSR): Considerations for Accurate Measurement and Reporting Martyn Quinn Eastern Region Biosolids Coordinator 329-3505](https://reader031.fdocuments.in/reader031/viewer/2022030501/5aad4b187f8b9aa06a8e1edb/html5/thumbnails/3.jpg)
Why is this important?Why is this important?
The calorific value provides food for not onlymicrobes, but also potential vectors(rodents, birds etc).
Calorific content also increases potential odorsand consequently increases attraction of vectors(and unwanted public attention).
![Page 4: Considerations for Accurate Measurement and … Solids Reduction (VSR): Considerations for Accurate Measurement and Reporting Martyn Quinn Eastern Region Biosolids Coordinator 329-3505](https://reader031.fdocuments.in/reader031/viewer/2022030501/5aad4b187f8b9aa06a8e1edb/html5/thumbnails/4.jpg)
Why do you care?Why do you care?
The Washington State Regulation allows VAR (VectorAttraction Reduction) requirements to be met byquantifying and reporting adequate VSR (rather thanrelying on incorporation or lime treatment)
•This allows sites to surface apply with out incorporation(no till).
•Fulfills VAR requirement for exceptional quality status(allowing resale).
![Page 5: Considerations for Accurate Measurement and … Solids Reduction (VSR): Considerations for Accurate Measurement and Reporting Martyn Quinn Eastern Region Biosolids Coordinator 329-3505](https://reader031.fdocuments.in/reader031/viewer/2022030501/5aad4b187f8b9aa06a8e1edb/html5/thumbnails/5.jpg)
Options:Options:
For aerobic or anaerobic digestersReduce volatile solids in the sludge by a minimum of 38 %
Bench testing (post digestion- often used for lagoon solids)
•Anaerobically digested solids must be reduced less than17% in the 40 day testing period
•Aerobically digested solids must be reduced less than15% in the 30 day testing period.
![Page 6: Considerations for Accurate Measurement and … Solids Reduction (VSR): Considerations for Accurate Measurement and Reporting Martyn Quinn Eastern Region Biosolids Coordinator 329-3505](https://reader031.fdocuments.in/reader031/viewer/2022030501/5aad4b187f8b9aa06a8e1edb/html5/thumbnails/6.jpg)
Where to take appropriate measurementsWhere to take appropriate measurements
VSR may be measured across any part of the sludge-specific process
e.g. digester influent to digester effluent, dewatered materialoff of a press, drying beds, lagoon material etc.
Not at the headworks or prior to any wastewater specificprocesses.
![Page 7: Considerations for Accurate Measurement and … Solids Reduction (VSR): Considerations for Accurate Measurement and Reporting Martyn Quinn Eastern Region Biosolids Coordinator 329-3505](https://reader031.fdocuments.in/reader031/viewer/2022030501/5aad4b187f8b9aa06a8e1edb/html5/thumbnails/7.jpg)
What calculations to useWhat calculations to use
Approximate mass balance equation
Full mass balance equation
Van Kleeck equation
![Page 8: Considerations for Accurate Measurement and … Solids Reduction (VSR): Considerations for Accurate Measurement and Reporting Martyn Quinn Eastern Region Biosolids Coordinator 329-3505](https://reader031.fdocuments.in/reader031/viewer/2022030501/5aad4b187f8b9aa06a8e1edb/html5/thumbnails/8.jpg)
Van Van KleeckKleeck equation equation
Assumes that fixed solids are conserved during thedigestion process - creates erroneous data if this is not thecase
Suitable only for steady-state, continuous mix digesterswith no decant or significant grit accumulation
If decant (supernatant) occurs, the volatile solids in thedecant must be consistent with that in the digester
If grit accumulation occurs, equation underestimatesvolatile solids.
![Page 9: Considerations for Accurate Measurement and … Solids Reduction (VSR): Considerations for Accurate Measurement and Reporting Martyn Quinn Eastern Region Biosolids Coordinator 329-3505](https://reader031.fdocuments.in/reader031/viewer/2022030501/5aad4b187f8b9aa06a8e1edb/html5/thumbnails/9.jpg)
Full mass balance equationFull mass balance equation
Appropriate for non-steady state situations
Requires data for:• Volumes• Total solids concentrations• Volatile solids concentration (total – fixed solids)
Can be used for all digester situations and operatingconditions
![Page 10: Considerations for Accurate Measurement and … Solids Reduction (VSR): Considerations for Accurate Measurement and Reporting Martyn Quinn Eastern Region Biosolids Coordinator 329-3505](https://reader031.fdocuments.in/reader031/viewer/2022030501/5aad4b187f8b9aa06a8e1edb/html5/thumbnails/10.jpg)
Approximate mass balance equationApproximate mass balance equation
Uses average values
Requires close to steady state situations, or continuousmix digester
Uniform daily flows
Accumulation of volatile solids from scum or settling willaffect accuracy
![Page 11: Considerations for Accurate Measurement and … Solids Reduction (VSR): Considerations for Accurate Measurement and Reporting Martyn Quinn Eastern Region Biosolids Coordinator 329-3505](https://reader031.fdocuments.in/reader031/viewer/2022030501/5aad4b187f8b9aa06a8e1edb/html5/thumbnails/11.jpg)
Data set handlingData set handling
Pennsylvania model provides a goodspreadsheet solution(Website address for this is on the handout)
Washington State Department of Ecology hasbeen working on a user friendly version
Ensuring that sampling locations are selectedcorrectly, and that there are an adequate numberof samples in the data set is important
![Page 12: Considerations for Accurate Measurement and … Solids Reduction (VSR): Considerations for Accurate Measurement and Reporting Martyn Quinn Eastern Region Biosolids Coordinator 329-3505](https://reader031.fdocuments.in/reader031/viewer/2022030501/5aad4b187f8b9aa06a8e1edb/html5/thumbnails/12.jpg)
Typicalvalueranges*Typicalvalueranges*
Total Volatile Fixed
Raw Sludge 2 – 8% 75% 20 - 30%
Raw and WAS 2 - 5% 80% 15 - 25%
Recirculated Sludge 1.5 - 3% 75% 20-30%
Supernatant < 1% 50% 40 – 60%
Digested Sludge 4 – 8% 50% 40 - 60%
*Copied form the Pennsylvania DEP model
![Page 13: Considerations for Accurate Measurement and … Solids Reduction (VSR): Considerations for Accurate Measurement and Reporting Martyn Quinn Eastern Region Biosolids Coordinator 329-3505](https://reader031.fdocuments.in/reader031/viewer/2022030501/5aad4b187f8b9aa06a8e1edb/html5/thumbnails/13.jpg)
Summary: What is important for accurate measurement?Summary: What is important for accurate measurement?
Correct sampling locations(encompass sludge specific treatments)
Adequate Sampling events(generation of adequate data)
Consideration of system fluctuations(changes in volume, charging or removing sludge from system, decante,silt, gravel and other remnants in the digester that detract from finalvolumes).
Correct choice of analytical method(which equation to use).
![Page 14: Considerations for Accurate Measurement and … Solids Reduction (VSR): Considerations for Accurate Measurement and Reporting Martyn Quinn Eastern Region Biosolids Coordinator 329-3505](https://reader031.fdocuments.in/reader031/viewer/2022030501/5aad4b187f8b9aa06a8e1edb/html5/thumbnails/14.jpg)
Bench testing requirementsBench testing requirements
Testing should commence within 6 hours of sample collection foranaerobic solids, and as soon as possible for aerobic solids.
Testing should at least commence on the day of sample collection.
Anaerobically digested solids must reduce in volatiles by lessthan 17% during the test.
Aerobically digested solids must reduce volatiles by less than15% during the test*.
The requirements for bench testing are covered in Appendix D of theWhite House document.
*Based on arithmetic means for all tests conducted
![Page 15: Considerations for Accurate Measurement and … Solids Reduction (VSR): Considerations for Accurate Measurement and Reporting Martyn Quinn Eastern Region Biosolids Coordinator 329-3505](https://reader031.fdocuments.in/reader031/viewer/2022030501/5aad4b187f8b9aa06a8e1edb/html5/thumbnails/15.jpg)
Consequences of incorrect measurement:Consequences of incorrect measurement:
Out of compliance (violation of rule)
Possible odor issues at application site.
Possible attraction of nuisance and pathogenspreading vectors to the site.
Possible increase in pathogen exposure to thepublic/site operatives.
None of these consequences are good
![Page 16: Considerations for Accurate Measurement and … Solids Reduction (VSR): Considerations for Accurate Measurement and Reporting Martyn Quinn Eastern Region Biosolids Coordinator 329-3505](https://reader031.fdocuments.in/reader031/viewer/2022030501/5aad4b187f8b9aa06a8e1edb/html5/thumbnails/16.jpg)