KÖBER SRL VADURI BRANCH USER MANUAL CONDENSING GAS BOILER C13SPV36MEF C14SPV25MEF Image for presentation only. Product may look slightly different depending on the area and the purchase period. KÖBER Ltd, no. 25 Vaduri, Alexandru cel Bun Commune, Neamt 617511, Romania Tel.:+40.233.24.17.46, 233.24.19.33, Fax:+40.233.24.19.29 www.motan.ro

Transcript of CONDENSING GAS BOILER C13SPV36MEF C14SPV25MEFmotan.ro/images/manuale/intl/EN_Manual utilizator...

Page 1: CONDENSING GAS BOILER C13SPV36MEF C14SPV25MEFmotan.ro/images/manuale/intl/EN_Manual utilizator C13_C14_ERP_E… · CONDENSING GAS BOILER C13SPV36MEF C14SPV25MEF Image for presentation

KÖBER SRL VADURI BRANCH

USER MANUAL

CONDENSING GAS BOILER

C13SPV36MEF

C14SPV25MEF

Image for presentation only. Product

may look slightly different depending

on the area and the purchase period.

KÖBER Ltd, no. 25 Vaduri, Alexandru cel Bun Commune, Neamt 617511, Romania Tel.:+40.233.24.17.46, 233.24.19.33, Fax:+40.233.24.19.29 www.motan.ro

Page 2: CONDENSING GAS BOILER C13SPV36MEF C14SPV25MEFmotan.ro/images/manuale/intl/EN_Manual utilizator C13_C14_ERP_E… · CONDENSING GAS BOILER C13SPV36MEF C14SPV25MEF Image for presentation

USER MANUAL CENTRAL HEATING BOILER TYPE C13SPV36MEF AND C14SPV25MEF

REV.12.06.2017 2 din 26

Contents

1 Safety instructions and symbols ................................................................................................................................................... 3 2 Valability of instructions ................................................................................................................................................................ 3 3 EC Marking .................................................................................................................................................................................... 3 4 Use according to destination ....................................................................................................................................................... 3 5 Safety instructions .......................................................................................................................................................................... 3 5.1 Instalation and adjustment ....................................................................................................................................................................3 5.2 Gas smell ...................................................................................................................................................................................................3 5.3 Changes in the area adiacent to the heating BOILER .....................................................................................................................3 6 Technical and functional characteristics .................................................................................................................................... 4 7 Mounting ........................................................................................................................................................................................ 5 7.1 Mounting set ............................................................................................................................................................................................5 7.2 Dimensions and mounting positions .....................................................................................................................................................5 8 Installation ...................................................................................................................................................................................... 6 8.1 Conditions for the installation of the central heating BOILER ..........................................................................................................6

8.1.1 Installation indication ...........................................................................................................................................................6 8.1.2 Protection of the BOILER in order to keep the warranty ................................................................................................6

8.2 Gas connecting pipe .............................................................................................................................................................................7 8.3 General directions for the heating installation ...................................................................................................................................7 8.4 General directions for the hot water circuit ........................................................................................................................................7 8.5 Connecting pipe of the condensation output duct .........................................................................................................................7 8.6 Connecting pipe of the safety valve ...................................................................................................................................................8 8.7 Air inlet pipe / burnt gases outlet pipe ................................................................................................................................................8 8.8 Electric grid connection .........................................................................................................................................................................8 9 Operation instructions ................................................................................................................................................................. 10 9.1 Control Panel LMC1X for boiler types C13SPV36MEF and C14SPV25MEF ................................................................................... 10

9.1.1 Description of functions and of graphic contexts diplayed on the control panel LMC1X ............................ 11 9.2 Control Panel LMC1112 for boiler versions C13SPV36MEF -CH1 and C13SPV36MEF -CH2 ...................................................... 12 Table 5: Control panel keys ........................................................................................................................................................................ 12

9.2.1 Description of functions and of graphic contexts diplayed on the control panel LMC1112 ........................ 13 9.3 Starting the boiler (control panel LMC1X and control panel LMC1112) ..................................................................................... 14 9.4 Choosing the functioning modes of the central heating BOILER ............................................................................................ 14 9.5 Functioning as domestic hot water BOILER (DHW) ......................................................................................................................... 14

9.5.1 DHW operation via an individual boiler connected to the boiler (see chapter 11 '' Operating modes '') ........ 14 9.6 Functioning as heating BOILER (HS) .................................................................................................................................................. 15 9.7 Preset functions related to BOILER safety ......................................................................................................................................... 15 6. Setting additional functions ................................................................................................................................................................ 15 9.8 Error signals ............................................................................................................................................................................................ 16 9.9 BOILER switch off in safety conditions ............................................................................................................................................... 17 9.10 User training ........................................................................................................................................................................................... 17 9.11 Quality Conditions and Warranty ...................................................................................................................................................... 17 10 Inspection and maintenance ..................................................................................................................................................... 17 10.1 Inspection and maintenance intervals ............................................................................................................................................. 17 11. Drawings necessary for mounting and installation ................................................................................................................... 18 11.2. Minimum distances recommended for the mounting of the co-axial kit ................................................................................... 18 11.3. Hydraulic characteristic of pump ...................................................................................................................................................... 19 11.4. Functioning schemes covered by warranty .................................................................................................................................... 20

11.4.1 Radiators central heating and instant preparation of hot water, C13SPV36MEF and C14SPV25MEF ................ 20 11.4.2 Underfloor central heating and instant preparation of hot water, C13SPV36MEF and C14SPV25MEF.............. 20 11.4.3 Radiators central heating and accummulation water tank, C13SPV36MEF and C14SPV25MEF boiler ............. 21 11.4.4 Underfloor central heating and accummulation water tank, C13SPV36MEF and C14SPV25MEF boiler ............ 21 11.4.5 Radiators central heating, C13SPV36MEF-CH2 boiler (without V3C valve) preparation ...................................... 22 11.4.6 Underfloor central heating, C13SPV36MEF-CH2 boiler (without V3C valve) ........................................................... 22 11.4.7 Raditors and underfloor central heating and external boiler for DHW, C13SPV36MEF-CH2 boiler ...................... 23 11.4.8 Raditors central heating and external boiler for DHW, C13SPV36MEF-CH2 boiler.................................................. 23 11.4.9 Underfloorcentral heating and external boiler for DHW, C13SPV36MEF-CH1 boiler .............................................. 24 11.4.10 Combined central heating and external boiler for DHW, C13SPV36MEF-CH1 boiler ....................................... 24 11.4.11 Radiators central heating, external boiler for DHW and solar panel, C13SPV36MEF-CH1 boiler .................... 25 11.4.12 Underfloor central heating, external boiler for DHW and solar panel, C13SPV36MEF-CH1 boiler .................. 25 11.4.13 Combined central heating, external boiler and solar panel, C13SPV36MEF-CH1 boiler ................................. 26

Page 3: CONDENSING GAS BOILER C13SPV36MEF C14SPV25MEFmotan.ro/images/manuale/intl/EN_Manual utilizator C13_C14_ERP_E… · CONDENSING GAS BOILER C13SPV36MEF C14SPV25MEF Image for presentation

USER MANUAL CENTRAL HEATING BOILER TYPE C13SPV36MEF AND C14SPV25MEF

REV.12.06.2017 3 din 26

1 Safety instructions and symbols When installing the central heating BOILER we ask you to respect the safety instructions contained in this manual! This manual is the property of KÖBER SRL-Vaduri branch. Copying or reproduction without written consent KÖBER SRL-Vaduri branch is strictly forbidden. The following lines explain the symbols used in the text:

Danger! – direct danger for corporal integrity and life.

Danger! – danger of death by electrocution.

Caution! – pontentially dangerous situation for the product and the environment.

Note! – useful notes and information. This symbol indicates a necessary activity.

2 Valability of instructions These instructions are valid exclusively for central heating BOILER type C13SPV36MEF and C14SPV25MEF.

3 EC Marking EC marking applied on this product guarantees that the equipment complies with the esential conditions stipulated in

the applicable European legislation: - Directive regarding gas equipment 2009/142/CE (ex. 90/396/CEE) - EcoDesign Directive 2009/125/EC - Directive regarding energy efficiency 92/42/EEC and European Regulations no.811-814/2013 - Directive regarding electromagnetic compatibility 2004/108/EC (ex. 89/366/CEE) - Directive for low frequency 2006/95/EC (ex. 73/23/EEC).

4 Use according to destination - Central heating boilers C13SPV36MEF;C14SPV25MEF are designed following current technical standards and observing recognized safety norms; - In case of misuse or inappropriate use, the health or life of users or third parties can be put in danger, as well as the central heating BOILER and other goods; - This equipment must not be used by people with limited psychological and sensitive capacities (including children), or by people with no experience or/ and no knowledge; - The BOILER provides both heating in closed circuit central heating installations, as well as hot water. Use for other purposes or for additional purposes other than stipulated is considered inappropriate use. The manufacturer is not responsible for possible damage resulting from inappropriate use. The user is the only one responsible; - Compliance with the use and installation instructions, the additional documentation, as well as with the inspection and maintenance stipulations is part of what is understood by use according to destination.

5 Safety instructions

5.1 Instalation and adjustment

Installation and commissioning can be done only by a company authorized and agreed by KÖBER SRL-Vaduri Branch! This company will assume responsibility for the correct installation and commissioning. Adjustment work, as well as maintenance and repair are allowed to be performed only by a company authorized and agreed by KÖBER SRL-Vaduri Branch!

Danger! Danger of death by poisoning and explosion because of breeches in the gas pipes and connections in case of incorrect installation! Danger of deterioration when inappropriate tools are used. For tightening or unscrewing connection screws use appropriate wrenches (no box wrenches, extensions etc).

5.2 Gas smell

When gas smell appears, take the following into account: - Do not activate electric switches in the dangerous zone; - Do not smoke in the dangerous zone; - Do not use mobile phones in the dangerous zone; - Turn off the gas tap; - Air the dangerous zone; - Notify the gas distribution company.

5.3 Changes in the area adiacent to the heating BOILER

Modifications of the following installations are not allowed: - The central heating BOILER; - The gas or water pipes or electric cables; - Air/ gas incoming/ outgoing pipes.

Page 4: CONDENSING GAS BOILER C13SPV36MEF C14SPV25MEFmotan.ro/images/manuale/intl/EN_Manual utilizator C13_C14_ERP_E… · CONDENSING GAS BOILER C13SPV36MEF C14SPV25MEF Image for presentation

USER MANUAL CENTRAL HEATING BOILER TYPE C13SPV36MEF AND C14SPV25MEF

REV.12.06.2017 4 din 26

6 Technical and functional characteristics

(**) – Standard central heating station is delivered with 1m co-axial kit; dual kit is delivered as accessory only on request

Tab.1 Technical characteristics Type C14SPV25MEF C13SPV36MEF Commercial name MKDens 25 MKDens 36

Gas category to be used I2H (GN-G20)

Flue type Forced

Burning room Air-tight

Efficiency stars (dir. 92/42/CEE) ****

Heating energy efficiency class A

DHW energy efficiency class A

DHW COMFORT class (EN13203) ***

NOx class(natural gas) 5

Nominal power - central heating (kW) 24 33

Minimal power (kW) 4.9 7.6

Output performance at nominal heat input at 80/60 °C (PCI) (%) 97 97

Output performance at nominal heat input at 50/30 °C (PCI) (%) 106 106

Gas pressure (on the regulator) 20 mbar (max. 25 mbar, min. 17 mbar)

Maximum pressure on the hot water circuit 8 bar

Maximum pressure on the thermal circuit 3 bar

Minimum pressure on the thermal circuit 0.8 bar

Temperature adjustment interval of thermal circuit 30÷80 °C

Temperature adjustment interval of thermal circuit - floor heating system

15÷45 °C

Temperature adjustment interval of the hot water circuit 30÷55 °C

Hot water flow at ∆ t = 30 °K

10 l/min 12 l/min

Electrical characteristics Power ~230VAC/50 Hz

Nominal power 80 W 106 W

Co

nst

ruc

tive

ch

ara

cte

ristic

s

Height 712 mm

Width 415 mm

Depth 324 mm

Height with installed elbow 850 mm

Pimary heat exchanger capacity ~1.4 l ~1.8 l

Connectors

Thermal input, output 3/4‘’

Cold water input, hot water output 1/2'’

Gas input 3/4'’

Expansion vessel with membrane 7 l 7 l

Evacuation type Coaxial Ø100/ Ø60

Twin Ø80

Permited flue lenght Coaxial - maxim 3m**

Twin - maxim 5m**

Evacuation type C13, C23, C33,C33x, C43,C53,C83

Class of electric protection Class I

Protection class IP 40

Page 5: CONDENSING GAS BOILER C13SPV36MEF C14SPV25MEFmotan.ro/images/manuale/intl/EN_Manual utilizator C13_C14_ERP_E… · CONDENSING GAS BOILER C13SPV36MEF C14SPV25MEF Image for presentation

USER MANUAL CENTRAL HEATING BOILER TYPE C13SPV36MEF AND C14SPV25MEF

REV.12.06.2017 5 din 26

7 Mounting

7.1 Mounting set

Check whether the mounting set is complete and undamaged – see table 2.

7.2 Dimensions and mounting positions

7.2.1 Installation site When choosing the installation site, please take into consideration the following safety instructions:

Caution! Do not install the BOILER in spaces that are exposed to freezing! In case of

freezing the sation can be damaged. This equipment can not be installed and used in open air. Outdoor installation can cause functioning flaws. Caution! It is not recommended to install the central heating BOILER in bathrooms or kitchens or other areas with high humidity. The BOILER can be installed only in rooms with maximum 60% humidity between 20-30°C in order to prevent the damaging of electronic components.

Caution! The burning air of the BOILER must not contain substances such as flourine

vapours, chlorine, sulphur, dissolvants, colorants, adhesives or gasoline. These substances can lead in time to the corrosion of the equipment and air/ gas incoming/ outgoing pipes. Legend: A – Thermal input connector B – Hot water output connector C - Fuel input connector D - Cold water input connector E - Thermal output connector

Fig. 1.2 Dimensions and mounting positions

Tab. 2 Mounting set

Pos. Pcs. Description 1 1 BOILER 2 1 BOILER support

3 1 Bag of small elements - it contains: - mounting screws 8x80 - 2 items.

4 1

Printed packet – it contains: - user manual - 1 item - CE conformity declaration - 1 item - warranty certificate – 1item

3

4

Fig. 1.1

Fig.1.2

Page 6: CONDENSING GAS BOILER C13SPV36MEF C14SPV25MEFmotan.ro/images/manuale/intl/EN_Manual utilizator C13_C14_ERP_E… · CONDENSING GAS BOILER C13SPV36MEF C14SPV25MEF Image for presentation

USER MANUAL CENTRAL HEATING BOILER TYPE C13SPV36MEF AND C14SPV25MEF

REV.12.06.2017 6 din 26

7.2.2 Minimum necessary distances/ free spaces for mounting Both for the mounting/ installation of the central heating BOILERs and for later maintenance operations you will need the following minimum distances (fig. 1.3), respectively minimum free spaces for mounting: – distance to the lateral: 100 mm – distance to the bottom part: 250 mm – distance to the upper part: 400 mm - distance to the front part: 500 mm

Caution! Danger of damaging the equipment by incorrect setting!

The equipment can be mounted only on a flat, fixed surface.

Note! Minimum necessary distances/ free

spaces for mounting are valid also for mounting with/ within pieces of furniture.

8 Installation Danger! Danger of death by poisoning and explosion because of breeches in the gas pipes and connections in case of incorrect installation! Installation and commissioning can be done only by a company authorized and agreed by KÖBER SRL-Vaduri Branch! This company will assume responsibility for the correct installation and commissioning.

8.1 Conditions for the installation of the central heating BOILER

8.1.1 Installation indication

The central heating BOILER will be subject to corrosion from the moment it is filled with water! To receive warranty during the entire warranty period it is essential to take into consideration the following directions in order not to increase the corrosion!

- The burning gas must have the sulphur content within the limits of the applicable European standard: it is accepted for a short period of time to have a maximum of 150 mg/m3, but the yearly average must be of 30 mg/m3. - The burning air must not contain chlorine, ammonia, alkaline agents, halogenated hydrocarbs, freon, plaster particles, lints, dirt or dust; - Installation of the central heating BOILER in the proximity of a swimming pool, washing machine or cleaner can result in the contamination of the burning air with these compounds. - Water pH must be within the following limits: 7,5<pH<9,5 It is recommended to check the water and thermal agent pH frequently and if the value does not fall within the limits provided by the manufacturer, it will be treated again. - Water asperity must be within the limits 5°F <TH <15°F (5°F (French degrees), equivalent to 50 mg CaCO3 or an equivalent quantity of other Ca and Mg salts). - It is recommended to have repeated BOILER startup cycles with the fuel tap off in order to air the installation. The BOILER is also provided with a manual ventilator, installed on the heat switch. - If the central heating BOILER is not used for a long period of time during the cold season, full emptying of the installation is recommended to prevent damage caused by freezing.

8.1.2 Protection of the BOILER in order to keep the warranty

Before and during installation, the central heating BOILER must be kept away from impurities: construction dust, sand, copper dust, fats etc as well as welding splashes, scoria. In any of theses cases, the installation must be washed with clean water mixed with a highly concentrated cleaning agent. Genereally, in order to keep the warranty it is necessary to apply any neccesary treatment to prevent the contamination of water with the following: � Black mud (magnetite - Fe3O4) formed as a result of the continuous electrolyte corrosion occurring in any installation which is not protected with an inhibitor. � Red mud (rust - Fe2O3) produced during oxidation. � Calcarous deposits produced especially on the hottest areas of the central heating BOILER.

A combination of these three factors mentioned above causes the majority of the problems occurring with heating systems. Caution! The presence of these substances (black mud/ red mud/ calcarous deposits) means that the standard measures to prevent problems of the heating system were not observed.

This is one of the causes resulting in losing warranty!

Fig. 1.3

Page 7: CONDENSING GAS BOILER C13SPV36MEF C14SPV25MEFmotan.ro/images/manuale/intl/EN_Manual utilizator C13_C14_ERP_E… · CONDENSING GAS BOILER C13SPV36MEF C14SPV25MEF Image for presentation

USER MANUAL CENTRAL HEATING BOILER TYPE C13SPV36MEF AND C14SPV25MEF

REV.12.06.2017 7 din 26

8.2 Gas connecting pipe

Danger! Danger of death by poisoning and explosion because of breeches in the gas pipes and connections in case of incorrect installation! Installation of gas pipes is allowed to be performed only by an authorized agent. During installation all legal stipulations, as well as the local regulations of gas distribution companies are to be observed. When installing the gas pipe it is essential that it is not tensed so as not to create areas of leakage!

Caution! Maximum safety pressure for the gas valve is 60 mbar! Going above this pressure limite may resul in damage. Work pressure with G20 natural gas functioning must be 20 mbar! Caution! Is is obligatory to istall a pressure regulator on the fuel input circuit, adjusted at 20 mbar. Caution! In case parasite voltage appears on the gas pipe, it can be insulated by installing an electroinsulating piece

(according to the Technical Norms for the planning and execution of natural gas input systems). Central heating BOILERs C13SPV36MEF, C14SPV25MEF function on GN natural gas. The gas connecting pipe is made of stainless steel with an interior diameter of 12.4 mm. The gas input pipe must not have a diameter smaller than that of the gas connecting pipe of the central heating BOILER. The fuel input must be done according to applicable legal stipulations.

8.3 General directions for the heating installation

When designing the central heating system, please take in consideration the hydraulic characteristic of the pump that equips this boiler model! See chapter 11.3 for pump characteristic.

Caution! Before connecting the central heating BOILER carefully wash the entire heating installation! In this way, you eliminate from the pipes various debris such as welding splashes, scoria, grummet, putty, dirt or similar. Otherwise, these substances can form deposits in the heating switcher and can cause damage or malfunctioning. Caution! It is obligatory to install an impurity filter on the return of the thermal circuit installation! When installing connecting pipes it is essential for these not to be tensed to avoid creating areas of leakage! Maximum working pressure allowed is 3bar. Recommended working pressure is 1.5 bar! Caution! It is forbidden to use the central heating BOILER without thermal agent or partilally filled – danger of explosion! It is forbidden to use the central heating BOILER if it is not completely aired!

The equipment is provided with a 7l capacity and 1 bar loading pressure expansion vessel. Before installing the equipment, check whether this volume is sufficient. If not, an additional expansion vessel must be installed on the aspiration side of the pump.

Caution! Check the pressure inside the expansion vessel before commissioning. Pressure inside the expansion vessel must be 0.8÷1bar.

8.4 General directions for the hot water circuit

Connect the central heating BOILER to the hot water installation.

It is obligatory to install filters to de-harden the water and a mechanical impurity filter on the cold water input connecting pipe!

Caution! When installing connecting pipes it is essential for these not to be tensed to avoid creating areas of leakage!

The apparition of pressure shocks (input pressures higher than 3-4 bars in addition to symoultaneously activating quick closing taps) can affect the components of the hydraulic circuit inside the central heating BOILER. We recommend the installation of a pressure regulator adjusted to 3-4 bars! Damage caused by the apparition of pressure shocks or by the use of higher pressure than recommended on the cold water input circuit is not covered by the warranty! We recommend the installation of a pressure regulator! Damage caused by the use of pressure higher than recommended on the cold water input circuit is not covered by the warranty! It is forbidden to install one-way valves on the the cold water input circuit. The cold water input pipe of the hot water preparation circuit will always be open (closing the network is done only by activating the taps at the consumer points) to allow take-over of possible dilatations on this circuit.

Note! It is recommended that the distance between the hot water connecting pipe of the central heation BOILER and the nearest conumer is minimum 6m of pipe. Otherwiswe, there is always the risk of hot water burns.

8.5 Connecting pipe of the condensation output duct

Danger! Danger of death by leakage of burning gases!

Page 8: CONDENSING GAS BOILER C13SPV36MEF C14SPV25MEFmotan.ro/images/manuale/intl/EN_Manual utilizator C13_C14_ERP_E… · CONDENSING GAS BOILER C13SPV36MEF C14SPV25MEF Image for presentation

USER MANUAL CENTRAL HEATING BOILER TYPE C13SPV36MEF AND C14SPV25MEF

REV.12.06.2017 8 din 26

The condensation output duct must not be water-proof connected to a used water pipe because otherwise the internal condensation seal box can be emptied by aspiration and the burning gases can get inside the room where the central heating BOILER is installed. The condensation resulting from the condensation of water vapours contained by the burning gases is taken out of the BOILER by means of the condensation output seal box (fig.1.5), which is located in the lower part of the central heating BOILER. As this condensation is acid with a pH of approximately 3.8÷5.4, the output must be done by means of a plastic tube (flexible) with an interior diameter of minimum Ø25 mm or larger, which is connected at one end to the hose of the seal box and at the other to a sewage pipe.

Before commissioning the central heating BOILER approximately 1/2 liters of water must be introduced by means of the burning gases output connecting pipe (fig. 1.4), to form a “water plug” inside the seal box – in this way we prevent burning gases to be evicted in the room. The route of condensation output must be continuously downwards (so as not to have areas of condensation stagnation, especially in areas where there is the danger of freezing). The route of the condensation output must respect the applicable norms regarding residual waters.

8.6 Connecting pipe of the safety valve

Caution! Danger of hot water burns!

The connecting pipe of the pressing of the safety valve is connected to the drain pipe to the sewage system. Otherwise, there is always the risk of flooding, for which the manufacturer of the central heating BOILER is not responsable.

8.7 Air inlet pipe / burnt gases outlet pipe

The central heating BOILER does not require air plugs in the room where it is installed. The air necessary for burning to ensure the efficient functioning of the central heating BOILER must to be taken from the outside of the building. The equipment is delivered with a co-xial or dual type air input/ burnt gases output system called an evacuation kit. The equipment is delivered with a standard co-axial evacuation kit. On demand, a dual evacualtion kit can be delivered. It is also possible to order additional 45° and 90° corners as well as 0.5m and 1m elongations for both the dual and the co-axial systems.

Caution! It is obligatory to place central heating BOILER in rooms with proper ventilation systems according to applicable

norms. Study the technical instructions before mounting/ installation, commissioning or maintenance or repair work. Under no circumstances the total length of the co-axial kit, including elongations, is to be longer than 3 m (without the first corner). Under no circumstances the total length of the dual kit, including elongations, is to be longer than 5 m (without the first corner).

Danger! It is completely forbidden to use the central heating BOILER without the burnt gases output pipes because it endangeres people’s life and health of people.

Replacement is to be performed only by authorized personnel following applicable laws and using only original spare parts provided by the producer.

8.8 Electric grid connection

The central heating BOILER must be connected to one-phase network of 230V - 50Hz with protection null. Dispersion withstand of the earthing switch (earthing) must comply with applicable norms (maximum 4 ohm, and the working null must not have residual current). Electric powering of the central heating BOILER will be executed from a separate circuit provided with differential protection fuses of 30 mA. External connections must comply with applicable norms. Connection to the electric grid of the building must allow the entire electric insulataion of the central heating BOILER for situations when interventions are required. Grid connection is done taking into account the symbolism of colours as follows: Brown = phase, Blue = null, Green and Yellow = earthing. The current plug must be accessible so that the user can easily disconnect it.

Fig.1.5

Fig. 1.4

Page 9: CONDENSING GAS BOILER C13SPV36MEF C14SPV25MEFmotan.ro/images/manuale/intl/EN_Manual utilizator C13_C14_ERP_E… · CONDENSING GAS BOILER C13SPV36MEF C14SPV25MEF Image for presentation

USER MANUAL CENTRAL HEATING BOILER TYPE C13SPV36MEF AND C14SPV25MEF

REV.12.06.2017 9 din 26

Caution! It is not allowed to mount the central heating BOILER with a defective electric installation or with no earthing.

Danger! Danger of death by electric shock with electric contacts!

8.9 Filling and emptying the heating circuit

Caution! Filling of the installation can be done only with the fuel tap closed. Danger of explosion when BOILER is turned on!

The following operations are executed to fill the installation: - install a flexible hose with interior diameter of 9mm to the manual airifier - fig. 1.8 (with central heating BOILERs without automatic airifier) - ellectrically power the central heating BOILER; - open the filling tap (fig. 1.6) of the central heating BOILER and of the thermal/ house water installation; - load the boiler with a pressure of about 0.4 bar, indicated on the display; - open the pump air vent; - activate the boiler ventilation module to vent the system: press the J5 (MENU / OK) key for activation and the pump will start, the boiler is in the OFF (Stand-by) state, to deactivate it press the J5 (MENU / OK) or by turning on the POWER button; - Adjust the pump operation (5, 6 or 7m) depending on the installation (see chapters 8.3 and 11.3); - continue to fill the system, with the ventilation function switched on up to 1.1-1.5 bar; - check the tightness of the entire system. If there are losses, the problems must be remedied; In the case of plants equipped with automatic ventilation: keep the pump on until noises are heard in the installation; In the case of plants without automatic ventilators: manually operate the manual air vent to remove the air from the main exchanger until noises are heard in the installation; - heat the radiators; - Make 2-3 cycles of 50-60 seconds of air-venting, following the steps described above; - check the system pressure indicated on the display. If necessary, fill with thermal agent following the above steps. - Remove the flexible hose. If necessary, fill with thermal agent following the above steps.

Caution! Obligatory operation! Check the correct functioning of the pump with no fuel in the central heating BOILER.

Functioning of the central heating BOILER with a blocked pump can lead to complete damage of the main heating switch.

Caution! Obligatory operation! Incorrect airing of the installation can cause damage of the main heating switch. Note! Recommended pressure on the thermal circuit is 1.5 bars.

The following operations are executed to empty the installation: Emptying is done by means of the emptying tap of the central heating BOILER. The emptying points must be located in accessible places so as to allow the water to be drained.

Caution!! Danger of hot water burns when emptying the BOILER.

Fig.1.8

Fig. 1.6

Page 10: CONDENSING GAS BOILER C13SPV36MEF C14SPV25MEFmotan.ro/images/manuale/intl/EN_Manual utilizator C13_C14_ERP_E… · CONDENSING GAS BOILER C13SPV36MEF C14SPV25MEF Image for presentation

USER MANUAL CENTRAL HEATING BOILER TYPE C13SPV36MEF AND C14SPV25MEF

REV.12.06.2017 10 din 26

9 Operation instructions

9.1 Control Panel LMC1X for boiler types C13SPV36MEF and C14SPV25MEF

The LMC1X control panel (fig.1.9) equipes the boiler types C13SPV36MEF and C14SPV25MEF. The LMC1X control panel (fig.1.9) allows the visualization and change of parameters defining the functioning of the central heating BOILER. It consists of: - 10 switches (J1÷J8, J10, J11) - tab.3; - LCD display, where communication messages (graphic symbols) are displayed. The meaning of the 15 types of symbols is

presented in table 4.

Fig. 1.9 Functions of keys on the control panel

Table 3: Control panel keys

Switch Adnotation Description: J1 P- Used to navigate the menu: will select the previous parameter J2 P+ Used to navigate the menu: will select the next parameter

J3 + Used to increase the value of the active parameter (selected)

J4 - Used to decrease the value of the active parameter (selected)

J5 MENU/OK Used to enter the menu

J6 POWER Used to turn the BOILER on/ off

J7 Used to change the functioning mode winter/ summer

J8 RESET Used to reset the control electronic board from an error state

J10 ibar Used to check (display) the pressure in the installation

J11 Light Used to activate/ deactivate lower light of the display

Table 4: Description of graphic symbols in the LCD display

Switch Adnotation Description:

S1 It diplays the temperature (°C), set value, parameter values, informative values, various messages („On”, „OFF”, „HELLO” etc.)

S2 It displays informative values, parameter values, parameter indexes, error counter index

S4 It displays the modulation of the flame

S5 It indicates the state of the BOILER (OFF = active symbol, ON = inactive symbol)

S6 It shows the presence of flame

S7 It shows whether the set functioning mode is SUMMER (active symbol)

S8 It shows whether the set functioning mode is WINTER (active symbol)

S9 It shows the functioning of the sation as thermal BOILER

S10

It shows the functioning of the sation as hot water BOILER

S11

Service submenu

S12

It shows the state of the function ”Confort”: active/inactive

S14

It shows the state of serial communication (RS232 with computer): active/inactive

S15 It shows the state of the function ”Economic”: active/inactive

S16

It shows the activation of the function Antifreeze

S18 It shows a pressure too low in the thermal installation (under 1,0 bar)

Fig. 1.9 LMC1X control panel

Page 11: CONDENSING GAS BOILER C13SPV36MEF C14SPV25MEFmotan.ro/images/manuale/intl/EN_Manual utilizator C13_C14_ERP_E… · CONDENSING GAS BOILER C13SPV36MEF C14SPV25MEF Image for presentation

USER MANUAL CENTRAL HEATING BOILER TYPE C13SPV36MEF AND C14SPV25MEF

REV.12.06.2017 11 din 26

9.1.1 Description of functions and of graphic contexts diplayed on the control panel LMC1X

9.1.1.1 Central heating BOILER startup control panel LMC1X

When turned on, the central heating BOILER is in an intermediary state for 5 seconds, necessary for the system to initialise. From the point of view of the user interface, there are two different functioning modes depending on the state of the BOILER: - if the BOILER was “ON” before the board was separated from the network, then symbol S1will display the welcoming message „HELLO” (see vedea figure 1.10); - if the BOILER was “OFF” before the board was separated from the network, then symbol S1will display nothing (see vedea figure 1.11).

9.1.1.2 LIGHT function control panel LMC1X

- The LIGHT key (J11 fig. 1.9) is used to activate/ deactivate the light on display function, except the moment when application is started and errors are displayed.

9.1.1.3 Graphic context – Stand-by control panel LMC1X

- This context is associated with an inactive/ waiting state of the central heating BOILER. In the stand-by state all the activation elements are inactive and every burning demand is ignored - An exception to the rule: the anti-freezing function (generated by a value of water temperature in the installation lower than 8°C, which wi l l in i t iate a burning cycle to prevent the f reezing of the thermal agent in the instal lat ion. Entering and exiting this regime is done by pressing POWER key for at least one second. Switching between the two contextual menus also sets the state of the BOILER from OFF to ON. The J6 key – POWER is active in any other contextual menu to facilitate the forced stop of the boiler in case of abnormal functioning. Possible actions: - POWER – comute between ON/OFF states; - RESET –used to reset possible errors. Figure 1.12 is a good example of display in the stand-by state (pressure on the thermal installation 1,2 bar).

9.1.1.4 G raphic context – waiting state (ON) control panel LMC1X

Waiting state is associated with a functioning state of the BOILER, but with no burning request. In this state, all the activating/state elements of the central heating BOILER are active and all burning requests are accepted if no error is present. In this state, the user can visualize all the informationabout the BOILER and have the required settings. Possible actions: - MENU/ OK – activates the menu of the user; - POWER –turns the BOILER on; - IN/SU –select the summer/ winter functioning modes; - LIGHT - activation or deactivation of light functions; - RESET –used to reset possible errors.

9.1.1.5 Graphic context – user menu control panel LMC1X

From the contetx ON by pressing the key J5 (MENU/OK) the user can have access to the interface of the user menu. With the help of this menu, the user can set the main functioning parameters of the central heating BOILER and activate/ deactivate different functions of the BOILER such as: - The temperature of the thermal agent on the thermal circuit; - The temperature of water on the hot water circuit ; - Activation/ deactivation of function „Confort”; - Activation/ deactivation of function „Economic”. Example – changing temperature on the thermal circuit. By pressing J5 key (MENU/OK), all the previous symbols on the display are deactivated, S10, S11, S12 and S15 are activated,

symbol S9 ( ) will flash and on symbol S1 the temperature on the thermal circuit will be displayed (figure 1.13). Changing the value of any parameter from the context of the user MENU can be done directly by pressing keys J3(+) and J4(–) when the current index is with the desired parameter. To go to the next parameter, or to the previous, respectively, use keys J1(P+) or J2(P-). In case of SERVICE ( ) symbol, pressing keys J3(+) and J4(–) does not produce any change.

To go back from the USER MENU to the main menu press J1(P-) key when the active symbol is S9 ( ), or press J2 (P+) key when

the active symbol S15( ). In case there is no activity of the user (no key from USER MENU is pressed) after 240 seconds the main menu will automatically come back. NOTE: after all parameters of the USER MENU have been gone through, if at least one parameter was modified, then this will be saved in the memory. Possible actions: - "P+" – goes to the next parameter/ function of the menu. It is also used to go out of the current menu by pressing repeatedly until the contextual menu is changed; - "P-" - goes to the previous parameter of the menu. It is also used to go out of the current menu by pressing repeatedly until the contextual menu is changed; - "+" – increases the current value of the parameter; - "–" - decreases the current value of the parameter;

figure1.10

Figure1.13

Figure1.12

Figure1.11

Page 12: CONDENSING GAS BOILER C13SPV36MEF C14SPV25MEFmotan.ro/images/manuale/intl/EN_Manual utilizator C13_C14_ERP_E… · CONDENSING GAS BOILER C13SPV36MEF C14SPV25MEF Image for presentation

USER MANUAL CENTRAL HEATING BOILER TYPE C13SPV36MEF AND C14SPV25MEF

REV.12.06.2017 12 din 26

To increase the efficiency of the menu, observe that the symbols that make up the menu are displayed when the USER MENIU is active. The current symbol is underlined by flashing on the display.

9.1.1.6 Graphic context – SERVICE submenu control panel LMC1X

In the Service submenu, various functioning parameters of the central heating BOILER can be viewed/ changed/ checked. This submenu can be accessed only by service personnel of an authorised company.

9.1.1.7 Graphic context – ECONOMIC submenu control panel LMC1X

If ECONOMIC function is activated ( ), the BOILER does not take into account the temperature set as heating regime. In this case, the burning cycle on the heating regime stops at 50ºC and restarts at 35ºC. This function cannot be active at the same time with the Confort function. Confort function has priority.

9.2 Control Panel LMC1112 for boiler versions C13SPV36MEF -CH1 and C13SPV36MEF -CH2

The LMC1112 control panel (fig.1.10) equips the boiler versions C13SPV36MEF -CH1 and C13SPV36MEF -CH2. The LMC1112 control panel (fig.1.10) allows the visualization and change of parameters defining the functioning of the central heating station. It consists of: - 8 keys (J1÷J8) - tab.5 - LCD display, where communication messages (graphic symbols) are displayed. The meaning of the 10 types of symbols

(S1÷S10) is presented in tab.6.

Table 5: Control panel keys

Tasta Adnotare Descriere:

J1 CH + Used to increase the set thermal temperature or to navigate the installation submenu J2 CH - Used to decrease the set thermal temperature or to navigate the installation submenu

J3 DHW + Used to increase the set temperature on hot water circuit or the value of the current parameter in the installation submenu

J4 DHW - Used to decrease the set temperature on hot water circuit or the value of the current parameter in the installation submenu

J5 POWER Used to switch the station on/ off

J6 RESET Used to reset the electronic control board from an error state

J7

Used to change the functioning mode winter/ summer

J8 LIGHT Used to activate/ deactivate the light on the display Table 6: Description of graphic symbols in the LCD display

Tasta Adnotare Descriere:

S1 It diplays the temperature (°C), set value, parameter values, informative values, various messages („On”, “SP”, “Co”, “EI”, “SI”, etc.)

S2 It displays informative values, parameter values, pressure

S3 It shows the state of the central heating station (Closed (OFF) = active symbol, Open (ON) = inactive symbol)

S4 It shows the presence of flame

S5 It shows whether the set functioning mode is SUMMER (active symbol)

S6 It shows whether the set functioning mode is WINTER (active symbol)

S7 The symbol is displayed continuously, which means that the station functions as thermal station. The symbol is displayed interrupted whenthe thermal temperature is set.

S8

If this symbol is displayed continuously it means that the station functions as hot water station. The symbol is displayed interrupted whenthe hot water temperature is set.

S9 It shows the fact that the S2 symbol displays the value of the pressure inside the installation (active symbol)

S10

It shows the fact that there was an unsaved change of parameters in the EEPROM memory (it flashes)

Fig. 1.10 LMC1112 Control panel

Page 13: CONDENSING GAS BOILER C13SPV36MEF C14SPV25MEFmotan.ro/images/manuale/intl/EN_Manual utilizator C13_C14_ERP_E… · CONDENSING GAS BOILER C13SPV36MEF C14SPV25MEF Image for presentation

USER MANUAL CENTRAL HEATING BOILER TYPE C13SPV36MEF AND C14SPV25MEF

REV.12.06.2017 13 din 26

9.2.1 Description of functions and of graphic contexts diplayed on the control panel LMC1112

9.2.1.1 LIGHT function control panel LMC1112

LIGHT k e y ( J8 fig.1.10) is used to activate/ deactivate the light on display function.

9.2.1.2 Graphic context – station startup control panel LMC1112

When started, the station is in an intermediary state for 5 seconds, necessary to initialise the system. During this interval the diplay shows only the message “On” on the S1 symbol on the interface (see figure 1.14).

9.2.1.3 Graphic context - Stand-by control panel LMC1112

This context is associated with an inactive/ waiting state of the central heating station. In the stand-by state all the activation elements are inactive and every burning demand is ignored. An exception to the rule: the anti-freezing function (generated by a value of water temperature in the installation lower than 9°C, which will initiate a burning cycle to prevent the freezing of the thermal agent in the installation. Entering and exiting this regine is done by pressing POWER key for at least one second. Possible actions: - POWER – comute between ON/OFF states; - LIGHT – activation or deactivation of light functions. Figure 1.15 is an example of display in the stand-by state (pressure on the thermal circuit 1,8 bar).

9.2.1.4 Graphic context – error state control panel LMC1112

The display of an error is sometimes asociated with a state of malfunctioning/ error of the station. There are three types of errors: - Critical errors: all the activating/state elements of the central heating station are inactive and any burning request is ignored. Getting out of this critical error state is done by pressing the RESET key; - Normal errors: all the activating/state elements of the central heating station are active and any burning request is ignored. Getting out of a normal error state is done by pressing the RESET key; - Informative errors: all the activating/state elements of the central heating station are active and all burning requests are accepted. Getting out of an informative state is done automatically when the cause of error disappears. In this context the diplay flashes a message with the error code. Possible actions: - RESET – reset critical or normal errors; - LIGHT - activation or deactivation of light functions – possible only if the central heating station is not in a state of critical error. Figura 1.16 is an example of display of an error (in our case E20).

9.2.1.5 Graphic context – waiting state control panel LMC1112

Waiting state is associated with a functioning state of the station, but with no burning request. All the activating/state elements of the central heating station are active and all burning requests are accepted if no error is present. In this state, the display shows pressure and thermal temperature, as well as the functioning mode summer/ winter.. Possible actions: - POWER - comute between ON/OFF states; - IN/SU – comute between summer/ winter functioning modes; - LIGHT - activation or deactivation of light functions; - CH+ - display and setting of maximum thermal temperature; - CH- - display and setting of minimum thermal temperature; - DHW+ - display and setting of maximum hot water temperature; - DHW- - display and setting of minimum hot water temperature. Figura 1.17 is an example of display in the waiting state (pressure in the heating installation is 1,4 bar, working mode is summer, and the temperature in the installation is 17°C

9.2.1.6 Graphic context – functioning state control panel LMC1112

This state is associated with the presence of flame or the functioning of the circulation pump of the station. In this state, all the activating/state elements of the central heating station are active and the burning request is accepted. The display shows the delivered instant temperature on the circuit meeting the request (heating ot hot water – symbols S5 or S6), regardless of the presence or lack of flame, the pressure inside the installation and the functioning mode summer/ winter Actiuni posibile: - POWER - comute between ON/OFF states; - IN/SU comute between summer/ winter functioning modes; - LIGHT - activation or deactivation of light functions; - CH+ - display and setting of maximum thermal temperature; - CH- - display and setting of minimum thermal temperature; - DHW+ - display and setting of maximum hot water temperature; - DHW- - display and setting of minimum hot water temperature. Figures 1.18 and 1.19 are two examples of graphic display of this context. Figure 1.18 – pressure in the heating installation is 1,8 bar, central heating station is in winter mode, flame is present, heating demand is satisfied and the instant thermal temperature is 43°C;

Fig.1.14

Fig.1.15

Fig.1.16

Fig.1.17

Fig.1.18

Page 14: CONDENSING GAS BOILER C13SPV36MEF C14SPV25MEFmotan.ro/images/manuale/intl/EN_Manual utilizator C13_C14_ERP_E… · CONDENSING GAS BOILER C13SPV36MEF C14SPV25MEF Image for presentation

USER MANUAL CENTRAL HEATING BOILER TYPE C13SPV36MEF AND C14SPV25MEF

REV.12.06.2017 14 din 26

Figura 1.19 – pressure in the heating installation is 1,7 bar, central heating station is set on winter mode, flame is present, station deliveres hot water, and the instant hot water temperature is 53°C.

9.2.1.7 Graphic context – adjustment of functioning parameters control panel LMC1112

The adjustment of the main functions of the station (thermal temperature, hot water temperature) can be done both in the waiting state and in the functioning state. When we enter the state display of these values, the last value previously set will be displayed. Only in the period the set value is displayed we can make changes of its value. Practically, at any moment of functioning of the station, by pressing J1 (CH+) or J2 (CH-) keys, the set value of the thermal temperature will be displayed and can be changed. Similarlry, at any moment of functioning of the station, by pressing the J3 (DHW+) or J4 (DHW-) keys, the set value of the hot water temperature will be displayed and can be changed. While doing these settings, the display will show the value of the set temperature (thermal or hot water), the pressure in the installation and the functioning mode of the station (winter/ summer). Getting out of this setting mode is done automatically if no key is pressed for at least 3 seconds. Figures 1.20 and 1.21 are two examples of displaying temperature in the setting mode. Figure 1.20 – pressure in the heating installation is 1,8 bar, central heating station is set on winter mode, set value of thermal temperature is 42°C; Figure 1.21 – pressure in the heating installation 1,6 bar, central heating station is set on winter mode, set value of hot water temperature is 60°C. Starting the boiler and choosing the operating mode:

9.3 Starting the boiler (control panel LMC1X and control panel LMC1112)

To turn on the boiler press the POWER key fig. 1.9 or 1.10.

9.4 Choosing the functioning modes of the central heating BOILER

Choosing the functioning regime winter/ summer

By pressing J7 key ( ) the functioning regime can be switched from winter to summer or the other way around. This can be viewed on the display, symbol S7/S8 will be activated. Adjusting temperature on the thermal circuit The adjustment of temperature is done by pressing J5 (MENU/OK) and by pressing J1(P-) or J2(P+) until symbol S9( ) flashes and symbol S1 displays the temperature of the thermal agent. To increase/ decrease use keys "+" and "–". Adjusting water temperature on the hot water circuit

The adjustment of temperature is done by pressing J5 (MENU/OK) and by pressing J1(P-) or J2(P+) until symbol S10( ) flashes. To increase/ decrease use keys "+" and "–".

9.5 Functioning as domestic hot water BOILER (DHW)

The BOILER can function as DHW in both seasons – winter and summer. The DHW request has priority over the heating request in the „winter” mode. The BOILER can function as instant DHW or as accumulation boiler DHW (the boiler is purchased separately). For the functioning of the BOILER as an accumulation boiler DHW BOILER please address an authorised service company. In intant regime, the minimum flow of hot water detected by the BOILER is 2.4 l/min. For confort in using the BOILER as a DHW BOILER we recommend to exploit the BOILER at a flow of approximately 7-8 l/min. When the BOILER functions with low flows, the BOILER functions continuously at the minimum charge as long as the hot water temperature is under the threshold limit of 63°C. When the hot water temperature reaches the mentioned limit of 63°C, the burner is closed and a new burning will happen when the hot water temperature is lower than the limit of 60°C. When the BOILER functions with high flows, the hot water temperature will be the opposite of the hot water flow, but lower than the set temperature. With instant DHW configuration on request the CONFORT function can be activated. This function allows the delivery of hot water as soon as possible, while keeping the boiler hot. If the function is active, the boiler starts when the hot water temperature is equal to the set hot water temperature; the boiler stops when the hot water temperature is 8°C ( fixed value) higher than the set hot water temperature. If the water heated in this way is not consumed within one hour, the CONFORT function is automatically deactivated. Activation/ deactivation of the function is done by pressing J5 (MENU/OK) key, press J1 (P-) or J2(P+) key until the symbol

S12( ) flashes. Press J3 (P+) or J4(P-) for activation/ deactivation.

9.5.1 Domestic hot water operation via an individual boiler connected to the boiler (see chapter 11 '' Operating modes '')

For hot water DHW operation, contact your authorized service provider, approved and trained by KOBER SRL Vaduri Branch! C13GC35; C14GC25 boilers can work with an accumulation boiler to produce domestic hot water in accumulation mode. C13GC35-CH1 and C13GC35-CH2 (boiler versions designed only for central heating preparation) can work with a hot-water tank with coil, for domestic hot water production. The boilers can work this way for both seasons ("Winter" and "Summer"). DHW heating demand by boiler is the priority of heating demand in AT mode. If the operation with a storage/preparation tank is set, DHW demand is triggered by the boiler temperature sensor. The boiler will operate in DHW mode when the water temperature in the tank drops below the value set by user. To homogenize the water temperature in the boiler, the boiler pump will continue to operate for a while (indicated by parameter SP:17) after any burning cycle. For any type of boiler, the user will set DHW temperature in the boiler. The boiler will provide hot water at 70 ° C. The user can limit hot water temperature from the boiler circuit board. In the case of continuous operation of the boiler at minimum capacity in DHW mode, the boiler water temperature might exceed the value of 70 ° C. Therefore, for safety reasons, the burner is off (the gas valve will be closed) when the boiler water temperature reaches 73 ° C (fixed value); circulation pump will continue to operate. A new ignition will take place after the water temperature drops below 70°C

Fig.1.19

Fig.1.20

Fig.1.21

Page 15: CONDENSING GAS BOILER C13SPV36MEF C14SPV25MEFmotan.ro/images/manuale/intl/EN_Manual utilizator C13_C14_ERP_E… · CONDENSING GAS BOILER C13SPV36MEF C14SPV25MEF Image for presentation

USER MANUAL CENTRAL HEATING BOILER TYPE C13SPV36MEF AND C14SPV25MEF

REV.12.06.2017 15 din 26

In case the boiler is configured to work with boiler, the function ANTILEGIONELLA is activated automatically. This means that the boiler temperature is maintained at an elevated temperature for an hour, once every week.

9.6 Functioning as heating BOILER (HS)

The BOILER functions in this mode when „winter” season is selected. For the selection of the type of heating installation (floor or radiators) please contact an authorised service company. If a thermoregulator is connected to the electronic board, the BOILERs functions in thermal mode only when the surrounding temperature is lower than the set temperature in the thermoregulator.

9.7 Preset functions related to BOILER safety

1. Anti-freezing protection function. If the temperature in the installation drops below 9°C, the system turns on the heating at minimum charge until the temperature reaches 30°C. 2. Post-circulation of the hot water and heating pump function. The post-circulation cycle starts only if the system is not in the BURNING state. Advantages: a) it prevents the water from becoming BOILERary at high temperatures inside the heat switch. In this way, calcareous deposits are reduced significantly b) it prevents water from boiling inside the heat switch in the post-heat interval. These advantages have as result the protection of the heat switch. 3. Pump anti-blocking system and three-way valve. If the BOILER did not go through a burning cycle in the last 24h, the pump will be started for 12 seconds to avoid its blocking. In this time the three-way valve is also activated and deactivated. 4. Post-ventilation After each BOILER stop, the ventilator still functions for some time to evacuate completely the burning gases out of the BOILER and also the water vapours they contain. In this way, both the ventilator control electric circuit and the primary heat switch, which cools down partially, are protected. 5. “Legionella” bacteria prevention function This function is active for the functioning of the BOILER as accumulation boiler WHW. When hot water is prepared in the boiler, the ANTILEGIONELLA function is actived automatically. This function implies that once a week the temperature of the water in the boiler is kept at the value of 65°C. 6. Setting additional functions Setting additional functions is done only in the "Service" menu. Please contact an authorised service company.

Page 16: CONDENSING GAS BOILER C13SPV36MEF C14SPV25MEFmotan.ro/images/manuale/intl/EN_Manual utilizator C13_C14_ERP_E… · CONDENSING GAS BOILER C13SPV36MEF C14SPV25MEF Image for presentation

USER MANUAL CENTRAL HEATING BOILER TYPE C13SPV36MEF AND C14SPV25MEF

REV.12.06.2017 16 din 26

9.8 Error signals Possible errors of the system are indicated by the following codes which appear on the display. Table 5: Meaning of error signals which appear on the display:

Code Class Non-

volatile Meaning Resetting mode

E01 C YES Problems of the feeding source AUTO- RESETTABLE when the cause diappears

E02 C NO Malfunction of the electronic board AUTO- RESETTABLE when the cause diappears

E04 C NO

Malfunctions of the interface mode AUTO- RESETTABLE when the cause diappears

E06 C NO Frequent resetting of the electronic board Manually resettable by pressing RESET

E07 N NO Installation parameters from the EEPROM

memory are corrupted Manually resettable by pressing RESET

E08 C YES Internal memory is corrupt Manually resettable by pressing RESET

E10 N NO

Water system pressure is incorrect. Water pressure in the installation is too low (lower

than 0,8 bars).

Resettable error when the cause disappears!

Fill the installation with water to the

recommended working pressure (1.5 bars) and

monitor the pressure for a few days.If pressure

continues to drop, check for water leakage on

one of the joints of the thermal installation. If you

checked and it is allright, but the presuure

continues to drop, contact an authorised

service company.

AUTO- RESETTABLE when the cause diappears

E11 N YES Rapid increase of the output water temperature (low flow or blocked pump – for flowswitch alternative)

AUTO- RESETTABLE when the cause diappears

E13 N NO Difference between input/ output temperatures too big

AUTO- RESETTABLE when the cause diappears

E15 N YES No water flow signal when the boiler pump is activated

Manually resettable by pressing RESET

E20 C YES Failed burning after three attempts Manually resettable by pressing RESET

E22 C YES Malfunction of flame detection Manually resettable by pressing RESET

E23 C YES Malfunction of flame detection Manually resettable by pressing RESET

E25 C YES Malfunction of the electronic board Manually resettable by pressing RESET

E30 N YES Malfunctioning burnt gases sensor Manually resettable by pressing RESET

E31 N NO

Malfunctioning thermal input sensor Manually resettable by pressing RESET when the cause disappears

E32 I NO

Malfunctioning thermal output sensor Manually resettable by pressing RESET when the cause disappears

E35 I NO

Malfunctioning external temperature sensor Manually resettable by pressing RESET when the cause disappears

E36 N, I NO

Mafunctioning WHW temperature Manually resettable by pressing RESET when the cause disappears

E37 N, I NO

Malfunctioning boiler temperature sensor 1 Manually resettable by pressing RESET when the cause disappears

E40 N YES Temperature of burning gases is too high Manually resettable by pressing RESET when the cause disappears

E41 N NO Temperature of thermal agent on the thermal

input is too high or too low Manually resettable by pressing RESET when the cause disappears

E42 I NO Temperature of thermal agent on the thermal

output is too high or too low Manually resettable by pressing RESET when the cause disappears

E45 I NO

External temperature too high Manually resettable by pressing RESET when the cause disappears

E46 N, I NO

DHW temperature too low/ too high Manually resettable by pressing RESET when the cause disappears

E47 N, I NO Temperature displayed by boiler sensor 1 is too

low/ high Manually resettable by pressing RESET when the cause disappears

E50 N YES Malfunctioning with feeding of ventilator at

230VAC Manually resettable by pressing RESET

E51 N YES Error with command/ state of ventilator Manually resettable by pressing RESET

E52 N YES Incorrect ventilator functioning (ex. turation) Manually resettable by pressing RESET

Page 17: CONDENSING GAS BOILER C13SPV36MEF C14SPV25MEFmotan.ro/images/manuale/intl/EN_Manual utilizator C13_C14_ERP_E… · CONDENSING GAS BOILER C13SPV36MEF C14SPV25MEF Image for presentation

USER MANUAL CENTRAL HEATING BOILER TYPE C13SPV36MEF AND C14SPV25MEF

REV.12.06.2017 17 din 26

9.9 BOILER switch off in safety conditions

If the user observes abnormal functioning of the equipment, if error codes are displayed repreatedly or if the user cannot understand the actions of the central heating BOILER, the user must stop the functioning of the BOILER immediately and in maximum safety conditions. For this, the user must perform the following operations: - Press POWER key and interrupt the functioning of the BOILER; -Disconnect the central heating BOILER from the main power line by unplugging it (if applicable); - Interrupt the fuel circuit by turning off the gas taps; -Interrupt the flow of house water and of heatined water by turning off the corresponding taps for these circuits; After the BOILER is switched off in safety conditions, the user will contact the authorized service company in the area.

9.10 User training

It is obligatory for the specialized personnel commissioning the BOILER to instruct the user about the following aspects: 1. Central heating BOILER switch on/ off procedure in safety conditions by checking the following elements: - electrical power connection; - fuel (gas) connection; - feeding and filling the thermal circuit; - the BOILER filling tap must be turned off; - the pressure in the installation by reading the control panel (1.5bar); - the BOILER taps on the house water circuit must be turned on. 2. The functioning way of the BOILER and possible problems that may occur. Also each key and symbol on the control panel must be explained. 3. Warn the user that a drop in the water pressure of the system is caused by loss of thermal agent which needs to be mended before using the BOILER again. 4. Warn the user on the works performed on the air/ gases input/ output systems. Warn the user that changing them is strictly forbidden. 5. It is recommended that the user should have the BOILER verified by an authorized person at least once a year. 6. Warn the user about the the precautions that need to be taken against freezing. 7. Hand the user the user manual of the central heating BOILER. At the end of training a commissioning statement is signed (table 2), by which the user signs that they are aware of the correct way of using the central heating BOILER. . This statement is also signed by the authorized person who commissioned the central heating BOILER. The authorised person who commissions the BOILER has the right to refuse to sign the BOILER commissioning statement if they notice defects of the local connecting installations and will not sign the commissioning statement until these defects have been remedied.

9.11 Quality Conditions and Warranty

The company KÖBER S.R.L. - VADURI BRANCH as the manufacturer, guarantees the correct functioning of the central heating BOILER if are observed ALL conditions for the installation, commissioning, use and periodical technical revision established in the “Warranty Certificate” given by the manufacturer and signed by the authorized company in the presence of the beneficiary when the product is purchased. The Warranty Certificate that comes with the product details all the limits of the warranty. Please carefully follow the directions in the Warranty Certificate and before reporting any malfunctioning of the BOILER make sure that all the local connecting installations are of the required quality!

Caution! Not observing the conditions of the warranty certificate results in losing warranty.

10 Inspection and maintenance

10.1 Inspection and maintenance intervals

It is obligatory to perform the periodical technical inspection in accordance to applicable law. In the warranty period of the BOILER the periodical technical inspection will be performed by companies authorised by KÖBER S.R.L. - VADURI BRANCH. In order to ensure permanent availability, safety in functioning, efficiency and extended working life, it is recommended that a yearly technical inspection should be performed by the authorized agreed company. This is why we recommend that you sign a service and maintenance agreement. It is recommended that this inspection should be performed before the cold season when the BOILER is used at full capacity.

Danger! Inspections, maintenabce and repair work are allowed only to technicians authorised and agreed by KÖBER S.R.L. - VADURI BRANCH. Not having inspections/ maintenance work can result in material and physical damage.

In order to benefit from all the BOILER function for an extended period of time we recommend the use of original spare parts.

Page 18: CONDENSING GAS BOILER C13SPV36MEF C14SPV25MEFmotan.ro/images/manuale/intl/EN_Manual utilizator C13_C14_ERP_E… · CONDENSING GAS BOILER C13SPV36MEF C14SPV25MEF Image for presentation

USER MANUAL CENTRAL HEATING BOILER TYPE C13SPV36MEF AND C14SPV25MEF

REV.12.06.2017 18 din 26

11. Drawings necessary for mounting and installation 11.1. Types of configurartions for the mounting kit for air input/ burnt gases output

11.2. Minimum distances recommended for the mounting of the co-axial kit

No. Evacuation type

Evacuation pipes – minimum and maximum length (m) Ø (mm)

1 C13 Lmin = 1m

Lmin = 1 m

Lmax = 3 m

Lmax = 5 m

Ø 60/ Ø100 -concentrical

Ø80 / Ø80 - dual

2 C33, C33x Lmin = 1m

Lmin = 1 m

Lmax = 3 m

Lmax = 5 m

Ø 60/ Ø100 -concentrical

Ø80 / Ø80 - dual

3 C43 Lmin = 1 m Lmax = 5 m Ø80 / Ø80 - dual

4 C53 Lmin = 1 m Lmax = 5 m Ø80 / Ø80 - dual

5 C83 Lmin = 1 m Lmax = 5 m Ø80 / Ø80 – dual

6 C93/C93X Lmin = 1m

Lmin = 1 m

Lmax = 3 m

Lmax = 5 m

Ø 60/ Ø100 -concentrical

Ø80 / Ø80 - dual

H

Page 19: CONDENSING GAS BOILER C13SPV36MEF C14SPV25MEFmotan.ro/images/manuale/intl/EN_Manual utilizator C13_C14_ERP_E… · CONDENSING GAS BOILER C13SPV36MEF C14SPV25MEF Image for presentation

USER MANUAL CENTRAL HEATING BOILER TYPE C13SPV36MEF AND C14SPV25MEF

REV.12.06.2017 19 din 26

GARAGE, ANNEX, ETC. LEGEND: A – distance under the window/ ventilation hole = 300mm B - distance over the window/ ventilation hole = 300mm C – distance left/ right to the window/ ventilation hole = 300mm D, E – distance from the roof/ gutter = 250mm F – distance from the garage roof/ balcony = 250mm

G – distance to vertical gutter = 250mm H – distance to internal/ external corners = 250mm H* - distance to windows/ doors = 300mm I – distance to ground/ balcony = 300mm J – distance over the door = 600mm

L – distance to the door/ window in the garage = 1200mm M – vertical distance to another terminal = 1500mm N – horizontal distance to another terminal = 300mm O – distance to the wall of another construction = 1200mm

11.3. Hydraulic characteristic of pump

When designing the thermal installation, the hydraulic characteristics of the pump need to be taken into consideration.

Pump setting: The pump can be set to function in four modes (4 steps).

Table 6 – Pump functioning modes UPM3 Flex As

[m] LED 1 red

LED 2 yellow

LED 3 yellow

LED 4 yellow

LED 5 yellow

4 • • 5* • • • 6 • • • • 7 • • •

(*)functioning mode set in the factory. To set on another curve please contact the authorized service company.

NOTE! To save on energy and to maintain the possible functioning noises to a low level, please choose a low characteristic curve.

If the pump has detecte one or more errors, the bi-colour LED 1 changes from green to red. When an error is active, LEDs indicate the type of error as presented in table 7. If more alarms are active at the same time, LEDs show the rror with the highest priority. Tab. 7 Pump error codes

Display Meaning Pump action Repair 1 LED red + 1 LED yellow (LEDl 5)

Blocked rotor Pump tries to restart every 1.5 seconds

Wait or deblock the engine shaft

1 LED red + 1 LED yellow (LEDl 4)

Feeding voltage too low

Only warning, the pump functions Check the feeding

voltage

1 LED red + 1 LED yellow (LEDl 3)

Electrical error Pump is stopped because the feeding

volatage is too low or feeding is incorrect

Check the feeding voltage / replace the

pump

P P

um

p p

ressu

re [

kp

a]

80

70

60

50

40

30

20

10

0

Pump flow Q[mc/h]

LED 1

Page 20: CONDENSING GAS BOILER C13SPV36MEF C14SPV25MEFmotan.ro/images/manuale/intl/EN_Manual utilizator C13_C14_ERP_E… · CONDENSING GAS BOILER C13SPV36MEF C14SPV25MEF Image for presentation

USER MANUAL CENTRAL HEATING BOILER TYPE C13SPV36MEF AND C14SPV25MEF

REV.12.06.2017 20 din 26

11.4. Functioning schemes covered by warranty

11.4.1 Radiators central heating and instant preparation of hot water, C13SPV36MEF and C14SPV25MEF C13SPV36MEF and C14SPV25MEF boilers for central heating and instantaneous DHW preparation, with plate heat exchanger

11.4.2 Underfloor central heating and instant preparation of hot water, C13SPV36MEF and C14SPV25MEF

C13SPV36MEF and C14SPV25MEF boilers for central heating and instantaneous DHW preparation, with plate heat exchanger

Page 21: CONDENSING GAS BOILER C13SPV36MEF C14SPV25MEFmotan.ro/images/manuale/intl/EN_Manual utilizator C13_C14_ERP_E… · CONDENSING GAS BOILER C13SPV36MEF C14SPV25MEF Image for presentation

USER MANUAL CENTRAL HEATING BOILER TYPE C13SPV36MEF AND C14SPV25MEF

REV.12.06.2017 21 din 26

11.4.3 Radiators central heating and accumulated preparation of hot water (accummulation water tank), C13SPV36MEF and C14SPV25MEF

C13SPV36MEF and C14SPV25MEF boilers for central heating and instantaneous DHW preparation, with plate heat exchanger

11.4.4 Underfloor central heating and accumulated preparation of hot water (accummulation water tank), C13SPV36MEF and C14SPV25MEF

C13SPV36MEF and C14SPV25MEF boilers for central heating and instantaneous DHW preparation, with plate heat exchanger

Page 22: CONDENSING GAS BOILER C13SPV36MEF C14SPV25MEFmotan.ro/images/manuale/intl/EN_Manual utilizator C13_C14_ERP_E… · CONDENSING GAS BOILER C13SPV36MEF C14SPV25MEF Image for presentation

USER MANUAL CENTRAL HEATING BOILER TYPE C13SPV36MEF AND C14SPV25MEF

REV.12.06.2017 22 din 26

11.4.5 Radiators central heating, C13SPV36MEF-CH2 boiler (without V3C valve), only with central heating circuit preparation

11.4.6 Underfloor central heating, C13SPV36MEF-CH2 boiler (without V3C valve), only with central heating circuit preparation

Page 23: CONDENSING GAS BOILER C13SPV36MEF C14SPV25MEFmotan.ro/images/manuale/intl/EN_Manual utilizator C13_C14_ERP_E… · CONDENSING GAS BOILER C13SPV36MEF C14SPV25MEF Image for presentation

USER MANUAL CENTRAL HEATING BOILER TYPE C13SPV36MEF AND C14SPV25MEF

REV.12.06.2017 23 din 26

11.4.7 Raditors and underfloor central heating and external boiler for DHW, C13SPV36MEF-CH2 boiler

C13SPV36MEF-CH2 boiler (without V3C valve), only with central heating circuit preparation and preparation boiler for DHW preparation

11.4.8 Raditors central heating and external boiler for DHW, C13SPV36MEF-CH2 boiler

C13SPV36MEF-CH1 boiler (with V3C valve) only for central heating circuit preparation, and preparation boiler for DHW preparation

Page 24: CONDENSING GAS BOILER C13SPV36MEF C14SPV25MEFmotan.ro/images/manuale/intl/EN_Manual utilizator C13_C14_ERP_E… · CONDENSING GAS BOILER C13SPV36MEF C14SPV25MEF Image for presentation

USER MANUAL CENTRAL HEATING BOILER TYPE C13SPV36MEF AND C14SPV25MEF

REV.12.06.2017 24 din 26

11.4.9 Underfloorcentral heating and external boiler for DHW, C13SPV36MEF-CH1 boiler

C13SPV36MEF-CH1 boiler (with V3C valve) only for central heating circuit preparation, and preparation boiler for DHW preparation

11.4.10 Combine radiators and underfloor central heating and external boiler for DHW, C13SPV36MEF-CH1 boiler

C13SPV36MEF-CH1 boiler (with V3C valve) only for central heating circuit preparation, and preparation boiler for DHW preparation

Page 25: CONDENSING GAS BOILER C13SPV36MEF C14SPV25MEFmotan.ro/images/manuale/intl/EN_Manual utilizator C13_C14_ERP_E… · CONDENSING GAS BOILER C13SPV36MEF C14SPV25MEF Image for presentation

USER MANUAL CENTRAL HEATING BOILER TYPE C13SPV36MEF AND C14SPV25MEF

REV.12.06.2017 25 din 26

11.4.11 Radiators central heating, external boiler for DHW and solar panel, C13SPV36MEF-CH1 boiler

11.4.12 Underfloor central heating, external boiler for DHW and solar panel, C13SPV36MEF-CH1 boiler

Page 26: CONDENSING GAS BOILER C13SPV36MEF C14SPV25MEFmotan.ro/images/manuale/intl/EN_Manual utilizator C13_C14_ERP_E… · CONDENSING GAS BOILER C13SPV36MEF C14SPV25MEF Image for presentation

USER MANUAL CENTRAL HEATING BOILER TYPE C13SPV36MEF AND C14SPV25MEF

REV.12.06.2017 26 din 26

11.4.13 Combine radiators and underfloor central heating, external boiler for DHW and solar panel, C13SPV36MEF-CH1 boiler