Applied Geometry.Lindner Post Cap Ceilings and Plafotherm® Post Cap Heated/Chilled Ceilings

Concepts

Products

Service

Page 2: Concepts Products Service...Class 0 tested to BS 476 part 6/7 Sound absorption tested to DIN EN ISO 354 ASTM C 423 Durability exposure class A tested to DIN EN 13964 table 7 and 8

2

Building newsolutions.

Lindner undertakes major worldwide projects in all areas of interior finishes, insulation technology, industrial services and building facades. Frompre-planning through to project completion Lindner is your partner of choice.

The Company’s extensive manufacturing capability enables quality to be strictly maintained whilst allowing maximum flexibility to meet individual project requirements.

Environmental considerations are fundamental to all Lindner’s business principles.

Through partnerships with clients Lindner turns concepts into reality.

Choosing Lindner you have:Lindner Concepts:Tailored solutions specifically geared to satisfy individual project requirements

Lindner Products:Quality materials and systems to the very highest industry standards

Lindner Service:Comprehensive project management services

Page 3: Concepts Products Service...Class 0 tested to BS 476 part 6/7 Sound absorption tested to DIN EN ISO 354 ASTM C 423 Durability exposure class A tested to DIN EN 13964 table 7 and 8

3

Main photo: Biocenter Copenhagen, Denmark© Weiles Fotografi

Central railway station Cologne, Germany

Lindner Post Cap ceilings are the solid foundation for partitioning your rooms. Visible and concealed post cap profiles can be installed to align with mullions, reflecting exterior architectural design in the interior. We offer a choice of systems with linear post caps and cross noggins as well as crossing boxes. Distances between post caps are variable.

Provided additional bracing is in place, Post Cap ceilings allow you to install partition walls in any direction and at any point in your room. Various customised options are available, e.g. radially installed post caps combined with trapezoidal ceiling panels.

Unmatched functionality and accessibility, ensured by Swing-Down mechanisms and a patented Drop-Slide option, make this ceiling a secure choice.

For outstanding comfort and pleasant room temperature we offer integrated Heating and Cooling Technologies for almost all products in this range. Post caps, crossing boxes and panels can be fitted with Lindner Lighting Systems.

Lindner Post Cap CeilingsStraightforward, robust and really high-profi le.

Customer benefits at a glance

- Variable spacing between the post caps or ceiling panels of different sizes- Fixing of partition walls to post cap profiles- Wide choice of perforations- Smoothly integrated Lindner Lighting Systems- Integrated Heating and Cooling Systems create a pleasant temperature

Page 4: Concepts Products Service...Class 0 tested to BS 476 part 6/7 Sound absorption tested to DIN EN ISO 354 ASTM C 423 Durability exposure class A tested to DIN EN 13964 table 7 and 8

4

Post Cap CeilingsOur range.

System Page

LMD-B 100Linear Post Cap Ceiling Post Cap profiles visible, ceiling panels Lay-In, with Hook-On edge or with Fold-Down option

7

LMD-B 102Linear Post Cap CeilingPost Cap profiles visible, ceiling panels Lay-In or with Hook-On edge

8

LMD-B 110Post Cap Ceiling with Cross Noggins Post Cap profiles and Cross Noggins visible, ceiling panels Lay-In, with Hook-On edge or with Fold-Down option

9

LMD-B 111

Post Cap Ceiling with Cross Noggins and Crossing BoxesPost Cap profiles and Cross Noggins visible, Crossing Boxes for suspension, ceiling panels Lay-In, with Hook-On edge or with Fold-Down option

10

LMD-B 116Post Cap Ceiling with Cross Noggins Post Cap profiles visible, ceiling panels Lay-In or with Hook-On edge

11

LMD-B 117

Post Cap Ceiling with Cross Noggins and Crossing BoxesPost Cap profiles and Cross Noggins visible, Crossing Boxes for suspension, ceiling panels Lay-In, with Hook-On edge or with Fold-Down option

12

LMD-B 125Linear Post Cap CeilingPost Cap profiles visible, panels with Swing-Down opti-on on long side

13

LMD-B 137Linear Post Cap CeilingConcealed Post Cap profiles, removable ceiling panels

14

LMD-B 140Drop-Slide Post Cap CeilingPost Cap profiles visible, Drop-Slide panels

15

Aditional options Page

LMD-B .... SD Longitudinally sound-reduced ceilings 17

LMD-B .... Ceilings tested for stability in case of fire 18

Plafotherm® B Heated and Chilled Post Cap Ceiling 20-24

Lighting Lindner Lighting Systems 25

Page 5: Concepts Products Service...Class 0 tested to BS 476 part 6/7 Sound absorption tested to DIN EN ISO 354 ASTM C 423 Durability exposure class A tested to DIN EN 13964 table 7 and 8

5

EN 13964

Central railway station Cologne, Germay

Abengoa Palmas Altas Campus, Spain

© Mark Bentley Photography

Bosch Karlsruhe, Germany

Standard requirements

Building material class A2-s1, d0tested to EN 13501-1Class A tested to ASTM E 84Class 0 tested to BS 476 part 6/7

Sound absorptiontested to DIN EN ISO 354ASTM C 423

Durability exposure class Atested to DIN EN 13964 table 7 and 8

Quality Standard

Light reflectance approx. 82 %Lindner RAL 9010, acc. to Lindner, plain

Material

Dimensions: ceiling panels, length up to 3,000 mm,width up to 1,250 mm, dependent on length,made of zinc-galvanised steel.Edges: square.Perforation: see Surface BrochureSubstructure: post cap manufactured from zinc-galvanised steel, profile roll-formed or bent with standard lengths of 100 mm, 125 mm, 150 mm and 200 mm, including corresponding suspension system. Special post cap widths can be delivered on request.Surface: electrostatically applied powder-coatingColour: RAL 9010, other colours in RAL and NCS available.Sound absorption: to improve sound absorption different perforations as well as a range of inlays are available.Relevant norms: DIN EN 10152/10327/13964, BS 2989, DIN EN ISO 12944, ASTM A 653

Page 6: Concepts Products Service...Class 0 tested to BS 476 part 6/7 Sound absorption tested to DIN EN ISO 354 ASTM C 423 Durability exposure class A tested to DIN EN 13964 table 7 and 8

6

Siemens, Beijing

Page 7: Concepts Products Service...Class 0 tested to BS 476 part 6/7 Sound absorption tested to DIN EN ISO 354 ASTM C 423 Durability exposure class A tested to DIN EN 13964 table 7 and 8

7

LMD-B 100 features post cap profiles in standard widths of 100, 125, 150 and 200 mm. If necessary, par-tition walls can be attached to the post cap profiles by means of additional bracings. However, this method is only possible with Type 1 or Type 2 ceiling panels.

Post Cap ceilings are maintenance-friendly and well-priced ceiling systems. Ceiling panels Type 1 (Lay-In), Type 2 (Lay-In with Hook-On edge) and Type 3 (Lay-In with Hook-On notch) may be used separately or in combination.

Standard requirements

Ceiling panels Material Post cap detail

LMD-B 100 Type 1

LMD-B 100 Type 2

LMD-B 100 Type 3

Ceiling panels Made of steel, powder-coated.Aluminium or stainless steel available on request

Length up to 3,000 mm, width up to 1,250 mm with LMD-B 100 Type 1/2, with LMD-B 100 Type 3 width depends on chosen length and is up to 625 mm

LMD-B 100 Type 1 Lay-InLMD-B 100 Type 2 Lay-In with Hook-On edgeLMD-B 100 Type 3 Lay-In with Hook-On notch

C-Post Cap

Available in all standard perforations

LMD-B 100 Type 1

LMD-B 100 Type 2

LMD-B 100 Type 3

Tried and tested, but never excelled.Linear Post Cap Ceiling – Post Cap profiles visible, removable ceiling panels, Lay-In or with Fold-Down option

LMD-B 100

Page 8: Concepts Products Service...Class 0 tested to BS 476 part 6/7 Sound absorption tested to DIN EN ISO 354 ASTM C 423 Durability exposure class A tested to DIN EN 13964 table 7 and 8

8

Simply effective.Linear Post Cap Ceiling - Post Cap profiles visible, removable ceiling panels, Lay-In, with Hook-On edge or with Fold-Down option

LMD-B 102

Compared to other systems, LMD-B 102 with a standard post cap width of 100 mm proves to be one of our best-priced ceilings. The hangers are automatically secured against unintended loose-

ning from the post cap profiles due to a specially adapted design. Furthermore, it is environmentally-friendly due to savings of material.

Standard requirements

Ceiling panels Material Post cap detail

LMD-B 102 Type 1

LMD-B 102 Type 2

Ceiling panels Made of steel, powder-coated.Aluminium or stainless steel available on request

Length up to 3,000 mm, width up to 1,250 mm dependent on length

LMD-B 102 Type 1 Lay-InLMD-B 102 Type 2 Lay-In with Hook-On edge

G-Post Cap

Available in all standard perforations

LMD-B 102 Type 1

LMD-B 102 Type 2

Page 9: Concepts Products Service...Class 0 tested to BS 476 part 6/7 Sound absorption tested to DIN EN ISO 354 ASTM C 423 Durability exposure class A tested to DIN EN 13964 table 7 and 8

9

Extends your options.Post Cap Ceiling with Cross Noggins – Post Cap profiles and Cross Noggins visible, removable ceiling panels, Lay-In or with Fold-Down option

LMD-B 110

This ceiling system consists of suspended linear post caps with attached cross noggins, both available in widths of 100, 125, 150 and 200 mm. Ceiling panels

are installed from above. As well as its pleasing visual LMD-B 110 scores with its option for partition connection in any direction along the post cap.

Standard requirements

Ceiling panels Material Post cap detail

LMD-B 110 Type 1

LMD-B 110 Type 2

LMD-B 110 Type 3

Ceiling panels Made of steel, powder-coated.Aluminium or stainless steel available on request

Length up to 3,000 mm, width up to 1,250 mm with LMD-B 110 Type 1/2, with LMD-B 110 Type 3 width depends on chosen length and is up to 625 mm

LMD-B 110 Type 1 Lay-InLMD-B 110 Type 2 Lay-In with Hook-On edgeLMD-B 110 Type 3 Lay-In with Hook-On notch

Linear Post Cap profiles and Cross Noggins

Available in all standard perforations

LMD-B 110 Type 1

LMD-B 110 Type 2

LMD-B 110 Type 3

Page 10: Concepts Products Service...Class 0 tested to BS 476 part 6/7 Sound absorption tested to DIN EN ISO 354 ASTM C 423 Durability exposure class A tested to DIN EN 13964 table 7 and 8

10

Tightly crossed.Post Cap Ceiling with Cross Noggins and Crossing Boxes – Post Cap profiles visible, Crossing Boxes for suspension, removable ceiling panels

LMD-B 111

The distinct visual of this ceiling system is created with suspended crossing boxes and Hook-On cross noggins. Ceiling panels Type 1 (Lay-In), Type 2 (Lay-

In with Hook-On edge) and Type 3 (Lay-In with Hook-On notch) may be used separately or in combination.

Standard requirements

Ceiling panels Material Post cap detail

LMD-B 111 Type 1

LMD-B 111 Type 2

LMD-B 111 Type 3

Ceiling panels Made of steel, powder-coated.Aluminium or stainless steel available on request

Length up to 3,000 mm, width up to 1,250 mm with LMD-B 111 Type 1/2, with LMD-B 111 Type 3 width depends on chosen length and is up to 625 mm

LMD-B 111 Type 1 Lay-InLMD-B 111 Type 2 Lay-In with Hook-On edgeLMD-B 111 Type 3 Lay-In with Hook-On notch

Crossing Boxes and Cross Noggins with hitch technology

Available in all standard perforations

LMD-B 111 Type 1

LMD-B 111 Type 2

LMD-B 111 Type 3

Page 11: Concepts Products Service...Class 0 tested to BS 476 part 6/7 Sound absorption tested to DIN EN ISO 354 ASTM C 423 Durability exposure class A tested to DIN EN 13964 table 7 and 8

11

Effective crossing.Post Cap Ceiling with Cross Noggins - Post Cap profiles visible, removable ceiling panels, Lay-In, with Hook-On edge or Fold-Down option

LMD-B 116

Standard requirements

Ceiling panels Material Post cap detail

LMD-B 116 Type 1

LMD-B 116 Type 2

Ceiling panels Made of steel, powder-coated.Aluminium or stainless steel available on request

Length up to 3,000 mm, width up to 1,250 mm dependent on length

LMD-B 116 Type 1 Lay-InLMD-B 116 Type 2 Lay-In with Hook-On edge

G-Post Cap and Cross Noggins

Available in all standard perforations

LMD-B 116 Type 1

LMD-B 116 Type 2

Compared to other systems, LMD-B 116 with a standard post cap width of 100 mm proves to be one of our best-priced ceilings. The hangers are automatically secured

against unintended loosening from the post cap profiles due to a specially adapted design. Furthermore, it is environmentally-friendly due to savings of material.

Page 12: Concepts Products Service...Class 0 tested to BS 476 part 6/7 Sound absorption tested to DIN EN ISO 354 ASTM C 423 Durability exposure class A tested to DIN EN 13964 table 7 and 8

12

Comes in the most appealing dimensions.Post Cap Ceiling with Cross Noggins and Crossing Boxes – Post Cap profiles and Cross Noggins visible, Crossing Boxes for suspension, removable ceiling panels, either laid-in or with Hook-On notch

LMD-B 117

This system with post caps and cross noggins is a well-priced alternative to LMD-B 117. Post caps and cross noggins, available in standard widths of 100,

125, 150 or 200 mm, structure the ceiling. Hook-On ceiling panels and those with Hook-On notch or Hook-On edge can be combined.

Standard requirements

Ceiling panels Material Post cap detail

LMD-B 117 Type 1

LMD-B 117 Type 2

LMD-B 117 Type 3

Ceiling panelsMade of steel, powder-coated,Aluminium or stainless steelavailable on request

Length up to 3,000 mm, width up to 1,250 mm with LMD-B 117 Type 1/2, with LMD-B 117 Type 3 width depends on chosen length and is up to 625 mm

LMD-B 117 Type 1 Lay-InLMD-B 117 Type 2 Lay-In with Hook-On edgeLMD-B 117 Type 3 Lay-In with Hook-On notch

Crossing Box and Cross Noggin screwed

Available in all standard perforations

LMD-B 117 Type 1

LMD-B 117 Type 2

LMD-B 117 Type 3

Page 13: Concepts Products Service...Class 0 tested to BS 476 part 6/7 Sound absorption tested to DIN EN ISO 354 ASTM C 423 Durability exposure class A tested to DIN EN 13964 table 7 and 8

13

Never loses its swing.Linear Post Cap Ceiling – Post Cap profiles visible, panels with Swing-Down option on long side

LMD-B 125

If frequent maintenance work is required, LMD-B 125 is the perfect match. The ceiling panels’ reliable swing-down mechanism makes it very easy to access the ceiling cavity. The mechanism can be operated single-handedly with a special tool to allow the

panel to swing down. An economically favourable combination of Swing-Down and Lay-In panels is possible.

Hinging and locking elements are protected by

DBGM.

Standard requirements

Ceiling panels Material Post cap detail

LMD-B 125 Type 1

LMD-B 125 Type 2

Ceiling panels Made of steel, powder-coated.Aluminium or stainless steel available on request

Length up to 3,000 mm, width up to 625 mm dependent on length

LMD-B 125 Type 1 without centre operationLMD-B 125 Type 2 with centre operation

C-Post Cap

Available in all standard perforations

Page 14: Concepts Products Service...Class 0 tested to BS 476 part 6/7 Sound absorption tested to DIN EN ISO 354 ASTM C 423 Durability exposure class A tested to DIN EN 13964 table 7 and 8

14

Hidden powers.Linear Post Cap Ceiling – Concealed Post Cap profiles, removable ceiling panels

LMD-B 137

Concealed post caps of 100 mm in width designed with a centre groove, structure our LMD-B 137 ceilings. Partition walls may be fastened in these grooves. This system is very easy to handle in case

of maintenance works, because the ceiling panels are still removable, even if a partition wall is already fastened to the post cap.

Standard requirements

Ceiling panels Material Post cap detail

LMD-B 137 Type 1 Made of steel, powder-coated,Aluminium or stainless steelavailable on request

Length up to 3,000 mm, width up to 1,250 mm dependent on length

Concealed Post Cap with groove

Available in all standard perforations

LMD-B 137 Type 1

Page 15: Concepts Products Service...Class 0 tested to BS 476 part 6/7 Sound absorption tested to DIN EN ISO 354 ASTM C 423 Durability exposure class A tested to DIN EN 13964 table 7 and 8

15

Patented accessibility.Drop-Slide Post Cap Ceiling, Drop-Slide Post Cap profiles visible, Drop Slide panels

LMD-B 140

The wall connection profiles and the post cap profiles of LMD-B 140 are made of aluminium. The ceiling panels can be dropped and then be slid in either direction along the aluminium post caps: Thus, there will be no dangling ceiling panels interfering with maintenance works.Furthermore, the wall connection profiles are able to compensate for tolerances. In standard configurati-on, you can choose between aluminium drop-slide hook-on profiles (width: 30 mm) joined back to back

and aluminium drop-slide post cap profiles (width: 150 mm).

System is protected by EP/DBP

and DBGM.

Standard requirements

Ceiling panels Material Post cap detail

LMD-B 140 Type 1 Ceiling panels Made of steel, powder-coated.Aluminium or stainless steel available on request

Length up to 3,000 mm, width up to 600 mm dependent on length

Aluminium Drop Slide Hook-On profiles joined back to back or aluminium Drop-Slide Post Cap profile

Available in all standard perforations.Minimum purchase quantity for alu-minium Post Cap profiles on request

Hook-On profiles joined back to back

Aluminium Drop-Slide Post Cap profile

Page 16: Concepts Products Service...Class 0 tested to BS 476 part 6/7 Sound absorption tested to DIN EN ISO 354 ASTM C 423 Durability exposure class A tested to DIN EN 13964 table 7 and 8

16

Sound absorption Come to rest.

Rg – round holes in straight pitchRv – round holes arranged in diagonal pitch (60°)Rd – round holes arranged in diagonal pitch (45°)

Rg 0,7 - 1Hole diameter 0.7 mmopen area 1%valid for steel 0.6 mmacoustic tissue

w = 0.75SAA / s,m = 0.73NRC = 0.70

Rd 1,6 - 25Hole diameter 1.6 mmopen area 25 %valid for steel 0.6 mm acoustic tissue

w = 0.65 (L)SAA / s,m = 0.63NRC = 0.65

Rv 1,8 - 20Hole diameter 1.8 mmopen area 20 %valid for steel 0.6 mm acoustic tissue

w = 0.75 (L)SAA / s,m = 0.73NRC = 0.75

Rg 2,5 - 16Hole diameter 2.5 mmopen area 16 %valid for steel 0.6 mm acoustic tissue

w = 0.75 (L)SAA / s,m = 0.73NRC = 0.75

Rg 2,5 - 16Available with special tissue, to achieve sound absorption class B tested to DIN EN ISO 11 654

w = 0.80 (L)SAA / s,m = 0.81NRC = 0.80

Rg 3,0 - 17Hole diameter 3.0 mmopen area 17 %valid for steel 0.6 mm acoustic tissue

w = 0.70 (L)SAA / s,m = 0.69NRC = 0.70

Rv 3,0 - 20 Hole diameter 3.0 mmopen area 20 %valid for steel 0.6 mmacoustic tissue

w = 0.75 (L)SAA / s,m = 0.75NRC = 0.75

Example of the range of standard perforations available for ceilings without Heating and Cooling Technology.

Our Post Cap ceilings can be perforated in a variety of hole shapes and sizes. You will find other perforation options in our dedicated Surface Brochure. Depending on the choice of perforation the ceiling can become a highly effective acoustic barrier.

6.26.

2

2

22

2

3.83

3.323.32

5.5

5.5

5.5

5.5

6.5

6.5

So

un

d a

bso

rpti

on

coef

fici

ent

s�

0,00,20,40,60,81,0

Frequency in Hz125 500 1000 2000 4000250

So

un

d a

bso

rpti

on

coef

fici

ent

s�

0,00,20,40,60,81,0

Frequency in Hz125 500 1000 2000 4000250

So

un

d a

bso

rpti

on

coef

fici

ent

s�

0,00,20,40,60,81,0

Frequency in Hz125 500 1000 2000 4000250

So

un

d a

bso

rpti

on

coef

fici

ent

s�

0,00,20,40,60,81,0

Frequency in Hz125 500 1000 2000 4000250

So

un

d a

bso

rpti

on

coef

fici

ent

s�

0,00,20,40,60,81,0

Frequency in Hz125 500 1000 2000 4000250

0.00.20.40.60.81.0

125 500 1000 2000 4000250

So

un

d a

bso

rpti

on

coef

fici

ent

s�

Frequency in Hz

So

un

d a

bso

rpti

on

coef

fici

ent

s�

0,00,20,40,60,81,0

Frequency in Hz125 500 1000 2000 4000250

6,5

5,5 5,5

Page 17: Concepts Products Service...Class 0 tested to BS 476 part 6/7 Sound absorption tested to DIN EN ISO 354 ASTM C 423 Durability exposure class A tested to DIN EN 13964 table 7 and 8

17

Longitudinally sound-reduced ceilings

Today, modern buildings are expected to satisfy high demands. Design, performance, security and flexibility as well as long-term profitability must be granted. Furthermore, rooms have to make the people therein feel comfortable. All this can be accomplished by using longitudinally sound-reduced Lindner ceilings available with a range of different inlays. It goes without saying that we always provide for our ceiling panels to be easy to remove in case of maintenance works.

LMD-B 100 SD Lay-In sandwich elements Dn,f,w = 49 dB without barrier

LMD-B 101 SD Hook-On sandwich elements Dn,f,w = 49 dB without barrier

LMD-B 129 SD1)Lay-In/Swing-Down sandwich elements, fastening of partition walls in Post Cap grooves

Dn,f,w = 48 dB without barrier

LMD-B 137 SD1)Lay-In sandwich elements, fastening of partition walls in joints

Dn,f,w = 48 dB without barrier

LMD-B 138 SD1)Swing-Down sandwich elements, fastening of partition walls in joints

Rw = 40 dB * with barrier

LMD-B 100 SD, LMD-B 101 SD LMD-B 129 SD

LMD-B 137 SD LMD-B 138 SD

Rated normalised flanking level differenceDn,f,w laboratory-tested according to currently applicable standards* tested on site according to DIN EN ISO 140-4

1) Minimum purchase quantity for post cap profiles on request

Page 18: Concepts Products Service...Class 0 tested to BS 476 part 6/7 Sound absorption tested to DIN EN ISO 354 ASTM C 423 Durability exposure class A tested to DIN EN 13964 table 7 and 8

18

LMD-B 100

Classification: RF15 according to Belgian standard NBN 713-020

Panel dimensions:Maximum length: 3,000 mmMaximum width: 397 mmConstructional height of ceiling element: 50 mm

Test Reference No: 11934

Post Cap ceiling

LMD-B 101(LMD-B 200)

Classification: RF45 according to Belgian standard NBN 713-020

Panel dimensions:Maximum length: 3,180 mmMaximum width: 600 mmConstructional height of ceiling element: 50 mm

Test Reference No: 10840

Post Cap ceiling

LMD-B 119

Classification: SF15 according to French standard Arrêté du 3 août 1999 et son annexe II

Panel dimensions:Maximum length: 1,250mmMaximum width: 675 mmConstructional height of ceiling element: 30 mm

Test Reference No: RS 00-205/A

Post Cap ceiling

LMD-B 132

Classification: SF15 according to French standard Arrêté du 3 août 1999 et son annexe II

Panel dimensions:Maximum length: 770 mmMaximum width: 1,735 mmConstructional height of ceiling element: 40 mm

Test Reference No: RS 02-033/C

Post Cap ceiling with Swing-Down option

LMD-B 134

Classification: RF30 according to Belgian standard NBN 713-020

Panel dimensions:Maximum length: 2,000 mmMaximum width: 1,200 mmConstructional height of ceiling element: 62.5 mm

Test Reference No: 3446/2221 – Kra + 2010-A-033

Longitudinally sound-re-duced Post Cap ceiling

Ceilings tested for stability in case of fi re

Metal ceilings not only have to meet requirements for an impeccable appearance and good acoustic proper-ties but also for the adherence to safety requirements in case of fire. For this reason, the use of non-com-bustible components and to assure the stability of the ceiling in case of fire can be seen as decisive factors. Lindner ceiling systems show a high level of residual strength in spite of an exposure to high temperatures.

This compilation contains ceiling systems especially developed for specific projects. These ceiling systems may only be offered after having consulted our R&D Department!

Page 19: Concepts Products Service...Class 0 tested to BS 476 part 6/7 Sound absorption tested to DIN EN ISO 354 ASTM C 423 Durability exposure class A tested to DIN EN 13964 table 7 and 8

19

FC Bayern Munich

Page 20: Concepts Products Service...Class 0 tested to BS 476 part 6/7 Sound absorption tested to DIN EN ISO 354 ASTM C 423 Durability exposure class A tested to DIN EN 13964 table 7 and 8

20

Plafotherm® B

The integrated Heating and Cooling Technologies of Plafotherm® B create a pleasant temperature for any living and working environment. The tried and tested post cap system ensures safe handling. We will be glad to give your metal ceiling a distinctive look by applying one of our many eye-catching Lindner surfaces.

Longitudinally sound-reduced Plafotherm® B ... SD Heated/Chilled ceilings provide for utmost flexibility when it comes to changing the floor plan in the sim-plest way. For this reason, these ceilings are in many cases installed in combination with movable partition walls. The heating and cooling system is particularly suitable to ensure room-to-room sound absorption as it may provide for excellent longitudinal sound re-duction values between 43 dB and 62 dB, depending on the construction.

Post Cap at its best.Heated and Chilled Post Cap Ceilings

Page 21: Concepts Products Service...Class 0 tested to BS 476 part 6/7 Sound absorption tested to DIN EN ISO 354 ASTM C 423 Durability exposure class A tested to DIN EN 13964 table 7 and 8

21

Range

System

Plafotherm® B 100Linear Heated and Chilled Post Cap Ceiling Post Cap profiles visible, ceiling panels Lay-In, with Hook-On edge or with Fold-Down option

Plafotherm® B 110

Heated and Chilled Post Cap Ceiling with Cross Noggins Post Cap profiles and Cross Noggins visible, ceiling panels Lay-In, with Hook-On edge or with Fold-Down option

Plafotherm® B 111

Heated and Chilled Post Cap Ceiling with Cross Noggins and Crossing BoxesPost Cap profiles and Cross Noggins visible, Crossing Boxes for suspension, ceiling panels Lay-In, with Hook-On edge or with Fold-Down option

Plafotherm® B 117

Heated and Chilled Post Cap Ceiling with Cross Noggins and Crossing BoxesPost Cap profiles and Cross Noggins visible, Crossing Boxes for suspension, ceiling panels Lay-In, with Hook-On edge or with Fold-Down option

Plafotherm® B 125Linear Heated and Chilled Post Cap CeilingPost Cap profiles visible, panels with Swing-Down option on long side

Plafotherm® B 137Linear Heated and Chilled Post Cap CeilingConcealed Post Cap profiles, removable ceiling panels

Plafotherm® B 100 SDLinear Heated and Chilled Post Cap Ceiling, longitudi-nally sound-reducedLay-In sandwich elements

Plafotherm® B 137 SD

Linear Heated and Chilled Post Cap Ceiling, longitudi-nally sound-reducedLay-In sandwich elements, fastening of partition walls in joints

EN 13964 Quality Standard

Building material class A2-s1, d0tested to EN 13501-1

Sound absorptiontested to DIN EN ISO 354ASTM C 423

Durability exposure class Atested to DIN EN 13964 table 7 and 8

Heating capacity to DIN EN 14037Cooling capacity to DIN EN 14240

Standard requirements

Light reflectance approx. 82 %Lindner RAL 9010 acc. to Lindner, plain

Page 22: Concepts Products Service...Class 0 tested to BS 476 part 6/7 Sound absorption tested to DIN EN ISO 354 ASTM C 423 Durability exposure class A tested to DIN EN 13964 table 7 and 8

22

Technical details

Heating/Cooling Technology:Made of aluminium heat conducting profile with copper meanders, integrated into ceiling panel for thermal conductivity.

Heat conducting profile: aluminium profile, with standard widths of 60, 80 and 120 mmCopper meanders: copper coil, 12x0.5 or 12x0.75 mmWater volume: approx. 1 l/m²Tube distance: 80 - 150 mm

Recommended operation dataFlow temperature (cooling) 15 – 17 °CTemperature spread 2 – 4 KFlow temperature (heating) 30 – 35 °CTemperature spread 4 – 6 KRecommended pressure drops 25 – 30 kPa

Reactive capability curve

6,0 8,0 10,0 12,0 14,020

40

60

80

100

140

120

160

180

200

Sp

ecif

ic c

apac

ity

[W/m

²]

Excess or insufficient temperature [K]

CoolingHeating

DimensioningThe potential of innovative Heating and Cooling Technologies can be fully tapped by the use of project specific dimensioning. Trust in the experience of our experts, who will be pleased to carry out the dimensio-ning for your project.

DevelopmentOur products with Heating and Cooling Technologies have been developed to satisfy the demands of nati-onal and international markets. Our in-house sound laboratory uses highly sensitive measuring devices to test acceptable sound pressure levels for the Heating and Cooling Technologies. The heating and cooling performance of our systems are continuously opti-mised using test results of our own climate chamber which is officially accredited.

ServiceAs every hydraulic pipework of the building services the Heated/Chilled Ceiling has to be flushed, to protect the valves and the entire pipework system must be checked for leaks, using a pressure test, before the system is put into operation. For maximum operational reliability, we check the smooth flow for all meanders by means of state-of-the-art infrared camera systems with image recording of the tested zones. After the start of operation, you will receive the documentation of the pressure and flush checks as well as the thermography report confirming complete functionality of your Heated and Chilled Ceiling.

Determination of excess and insufficient temperatureTK = R – ( VL + RL)/2TH = ( VL + RL)/2 – R

TK = insufficient temperature (cooling) [K]TH = excess temperature (heating) [K]R = room temperature [C°]VL = flow temperature [C°]RL = return-flow temperature [C°]

Nominal cooling capacity according to DIN EN 14240 (10K) 103.3 W/m²

Nominal heating capacity according to DIN EN 14037 (15K) 118.4 W/m²

Page 23: Concepts Products Service...Class 0 tested to BS 476 part 6/7 Sound absorption tested to DIN EN ISO 354 ASTM C 423 Durability exposure class A tested to DIN EN 13964 table 7 and 8

23

Sound absorption

Rg 0,7 - 1hole diameter 0.7 mmopen area 1 %acoustic tissuemineral wool lining

w = 0.35 (L)SAA / s,m = 0.41NRC = 0.40

Rv 1,8 - 20hole diameter 1.8 mmopen area 20 %acoustically effective heat conducting profileacoustic tissuemineral wool lining

w = 0.50 (L)SAA / s,m = 0.64NRC = 0.65

Rv 1,8 - 20hole diameter 1.8 mmopen area 20 %acoustically effective heat conducting profile acoustic tissue

w = 0,70 (L)SAA / s,m = 0,74NRC = 0,75

Rv 2,0 - 20hole diameter 2.0 mmopen area 20 %acoustic tissuemineral wool lining

w = 0.55 (LM)SAA / s,m = 0.69NRC = 0.70

Rg 2,5 - 16hole diameter 2.5 mmopen area 16 %acoustic tissuemineral wool lining

w = 0.50 (L)SAA / s,m = 0.64NRC = 0.65

Example of the range of standard perforations available for Heated/Chilled Ceilings, measured at maximum occupancy.

As a matter of course, we build your Heated/Chilled Ceiling according to your requirements concerning the acoustic performance. Our wide range of perforation patterns not only improves sound absorbing properties but also the appearance of your metal ceiling. We measure the sound absorption at maximum occupancy with heat conducting profiles.

6,2

6,2

5.5

5.5

4.3

3.72 3.72

So

un

d a

bso

rpti

on

coef

fici

ent

s�

0,00,20,40,60,81,0

Frequency in Hz125 500 1000 2000 4000250

So

un

d a

bso

rpti

on

coef

fici

ent

s�

0,00,20,40,60,81,0

Frequency in Hz125 500 1000 2000 4000250

So

un

d a

bso

rpti

on

coef

fici

ent

s�

0,00,20,40,60,81,0

Frequency in Hz125 500 1000 2000 4000250

Rg – round holes in straight pitch, Rv – round holes arranged in diagonal pitch (60°), Rd – round holes arranged in diagonal pitch (45°)

Sch

alla

bso

rp-

tio

nsg

rad

0,00,20,40,60,81,0

Frequenz Hz125 500 1000 2000 4000250

Sch

alla

bso

rp-

tio

nsg

rad

0,00,20,40,60,81,0

Frequenz Hz125 500 1000 2000 4000250

Plafotherm® B 100 SD Dn,f,w = 48 dBLay-in sandwich elements,without barrier

Plafotherm® B 100 SD Dn,f,w = 62 dBLay-in sandwich elements,with barrier

Plafotherm® B 137 SD Dn,f,w = 48 dBLay-in sandwich elements,without barrier

Longitudinally sound-reduced

Page 24: Concepts Products Service...Class 0 tested to BS 476 part 6/7 Sound absorption tested to DIN EN ISO 354 ASTM C 423 Durability exposure class A tested to DIN EN 13964 table 7 and 8

24

Hydraulic components

Multifunctional regulation unitThe multifunctional regulation unit is ideal for heated and chilled ceiling systems. It consists of a multifunctional ball valve, a control valve with adjustable drive, system distributor, air-bleeding system and various connecting elements. This multifunctional ball valve makes it very easy to flush out and bleed the control zones independently of the main system. This means that the chilled ceiling can be maintained independently from other building trades.

Connection hoses and fittingsHigh-grade steel hoses are oxygen impermeable, tested to DIN 4726, and are used as connection hoses. These hoses are perfectly suited to accept a large number of fittings. A system distributor with three outgoing lines completes the system.

Multilayer composite (MV) pipe systemThe MV pipe system is oxygen impermeable as perDIN 4726 and includes an MV system distributor with twoand three outlets, MV clamped screw connection and special MV pressing transmission to which to fit the heating and cooling pipework.

Copper pipe systemFor main and distribution pipes, we offer high-quality, current-tested conduits made of copper as per EN 1057and fittings as per EN 1254.

For perfect heating and cooling connections, Lindner provides a great number of hydraulic components and accessory parts.

Advantages: - Tested system- One-stop solutions- Ideal for heating/cooling systems- Maintained independently from other building trades

Page 25: Concepts Products Service...Class 0 tested to BS 476 part 6/7 Sound absorption tested to DIN EN ISO 354 ASTM C 423 Durability exposure class A tested to DIN EN 13964 table 7 and 8

25

Integration is our passion!The combination of ceiling and light produces a well-rounded and functional visual effect.

Lindner Lighting systems

Type B 20 / B 25System Light for modular ceiling, the luminaries are installed between the ceiling panels. Construction (B 20) with aluminium cap, adapted for workstation lighting according to EN 12464 -1. Optimised louvre technology by means of above closed cross blades as well as the consistent use of reflection-strengthe-ned MIRO aluminium. Alternative construction with opal acrylic glass cover (Type B 25).

Technical detailsVoltage: 220-240 Volt / 50-60 HzProtection class: 1Protective system: IP 20Ballast: electronic ballastFinish: reflector grid/opal acrylic glassColour: available to mach ceiling panelsIlluminant: on site

Type L 100Lighting channel for continuous arrangement. The lighting system is an integral part and supporting element of the Lindner metal ceiling, thereby ensuring perfect alignment within the shortest possible installation time.

Technical detailsVoltage: 220-240 Volt / 50-60 HzProtection class: 1Protective system: IP 20Ballast: electronic ballastFinish: mirror grid or satin acrylic glass coverColour: available to mach ceiling panels 100

70

125

65

Page 26: Concepts Products Service...Class 0 tested to BS 476 part 6/7 Sound absorption tested to DIN EN ISO 354 ASTM C 423 Durability exposure class A tested to DIN EN 13964 table 7 and 8

26

Each one’s a specialist. Perforation range for our post caps

Post Cap options

General layout options

Standard C-post cap

Partition wall attachment requires additional bracing

C-post cap with 9 or 13 mm centre groove

C-shadow gap post cap

Lay-In post cap

Installation possibilities

100125150

100 Standard

100

Diagonalbracing

Page 27: Concepts Products Service...Class 0 tested to BS 476 part 6/7 Sound absorption tested to DIN EN ISO 354 ASTM C 423 Durability exposure class A tested to DIN EN 13964 table 7 and 8

27

Aluminium Drop-Slide post cap for LMD-B 140width: 150 mm

Metal ceiling suspended with lowerable and movable ceiling panels

Post cap for reduced ceiling to soffit height

Post cap directly fi xed with compensation bracket to concrete ceiling

Removable post cap

Hook-on metal ceiling panels with lay-in post cap. After removal of the post cap, the partition wall can be installed

directly to the concrete ceiling.

Concealed post cap

Hook-on ceiling with removable and concealed post cap. Having removed the removable post cap, the partition wall

can be attached to the concealed post cap.

Acousticbarrier

Removable and concealed post cap

Installation possibilities

38 -

50

mm

100

150

Page 28: Concepts Products Service...Class 0 tested to BS 476 part 6/7 Sound absorption tested to DIN EN ISO 354 ASTM C 423 Durability exposure class A tested to DIN EN 13964 table 7 and 8

28

Accurately separated.The visual of the ceiling system can be influenced by a selection of different joint designs. Standard panels come with C-shaped edges on long sides. By selecting C-Z-shaped edges the longitudinal and cross axes are overlapped; the joint appearing to be closed. Determine your choice of joint width by ordering panels with different spacers.

Joint designs

panel width panel width~3

panel width panel width~3

panel width panel widtheither 3, 8 or 10 mm

panel width panel widthpanel length

~5

Gasket filled joint

Butt joint

Joint with embossed panel turn-up

Panel abutment with joint and spacer

Panel abutment with spacer for open joint

Bevelled butt joint

5-8

5-8

panel width panel width panel width panel width

~7-15 mm

Page 29: Concepts Products Service...Class 0 tested to BS 476 part 6/7 Sound absorption tested to DIN EN ISO 354 ASTM C 423 Durability exposure class A tested to DIN EN 13964 table 7 and 8

29

Further wall connections available on request.

Steel L-perimeter trim hold-down clip, visible width: 25 mm

Aluminium L-perimeter trim with hold-down function hold-down sheetvisible width: 25 mm

pillar semiringcurved L-trimvisible width: variable

Steel shadow gap trimvisible width: 20 mm, shadow gap width: 20 mm

Aluminium shadow gap trim with hold-down functionhold-down sheetvisible width: 25 mm, shadow gap width: 20 mm

pillar semiringcurved shadow gap trimvisible width: 25 mm, shadow gap width: 20 mm

Wall connections can be realised in different ways - with and without shadow gap. To ensure that cut panels rest entirely on the trim´s supporting surface without any corrugation, hold-down clips and sheets are applied. Specially designed aluminium L-perimeter and shadow gap trims for columns provide for a clean connection to curved shapes.

Wall connectionsThe link between ceiling and wall.

Page 30: Concepts Products Service...Class 0 tested to BS 476 part 6/7 Sound absorption tested to DIN EN ISO 354 ASTM C 423 Durability exposure class A tested to DIN EN 13964 table 7 and 8

30

ARTlineSTYLEline

To create a top of the range visual effect your metal ceiling is available with a choice of ARTline/STYLEline wood surfaces. The wood surfaces are also available tested to ASTM E 84 class A, regarding fire behaviour of surfaces.

GRAPHICline

GRAPHICline permits to apply any desired pattern colour-fast, gloss-fast and light-fast, with a photo-realistic resolution of up to 1,200 dpi, to a great variety of surface textures and materials. All colours and images may be printed on panels of any desired size.

INOXlook

Lindner aluminium ceilings can be supplied with stainless steel appearance. The INOXlook surface is created by special rolling and anodising processes and is similar to a brushed stainless steel surface (grain 180). Aluminium manufactured to EN 485-4 and EN 573-3, anodised to EN 12373.

Meteo

We protect the substructure and surface of our systems against corrosion to allow them to be installed in external areas, swimming pools and underground car parks. The anti-corrosion coating Meteo is tested to EN 13964 table 8 / DIN 55928 part 8 / DIN EN ISO 12944.

AntiBac

We offer substructure and surface coating with our antibacterial finish for areas with enhanced hygienic requirements. The performance of AntiBac is tested to JIS Z 2801:2000.

Mutex

The structured surface of Mutex combines the visual characteristics of an unperforated but sound absorbing ceiling with the unique choice of a perforated metal ceiling. Mutex is tested to ASTM E 84 class A and also available as building material class A2-s1, d0 tested to DIN EN 13501-1.

Other surface options available.

Specialties Our surfaces – unrivalled choice.

Page 31: Concepts Products Service...Class 0 tested to BS 476 part 6/7 Sound absorption tested to DIN EN ISO 354 ASTM C 423 Durability exposure class A tested to DIN EN 13964 table 7 and 8

31

Specifications for tenders Guidelines

Request specifications for tenders by contacting us on:Phone +49 (0)8723/20-36 96Fax +49 (0)8723/20-26 90e-mail: [email protected] visit us on the internet at www.Lindner-Group.com.

Installation guidelines:All published information is in accordance with existing DIN and EN Standards and other relevant regulations. Lindner production conforms to Quality Management Certificate DIN EN ISO 9001 and is also certified by TÜV Management. The best visual result and performance of the ceiling will be achieved if installation is carried out in appropriate working conditions and with the utmost care.

Installation conditions:Installation of the substructure should only be started if the preliminary services are at a stage where it is safe and efficient to commence. The ceiling should only be installed when the room is dry and sealed, all wet trades are finished and all external glazing and doors are installed. Differing parameters may be necessary depending on the individual project. During the installation of the ceiling, room temperatures of 10-25°C should be ensured.

Service:Technical information and documents (product sheets with guide specifications and installation instructions, test certificates, samples etc.) are available on request. We gladly offer comprehensive consulting services, for example specific building authority needs.

Page 32: Concepts Products Service...Class 0 tested to BS 476 part 6/7 Sound absorption tested to DIN EN ISO 354 ASTM C 423 Durability exposure class A tested to DIN EN 13964 table 7 and 8

32

Lindner Concepts:

- Insulation Engineering and Industrial Service- Clean Rooms and Laboratories- Airports and Airlines- Railways and Tunnels- Studios and Concert Halls- Interior Fit-out and Furnishings- Cruise Liner and Ship Fit-out- Hotels and Resorts- General Contracting

Lindner Products:

- Facades- Ceiling Systems- Lights and Lighting Systems- Partition Systems- Doors- Floor Systems- Heating and Cooling Technologies- Dry Lining Systems

Lindner Service:

- Green Building- Deconstruction and Gutting- Clearance of Harmful Substances- Research and Development- Delivery- General Planning- Installation- Maintenance- Public-Private Partnership (PPP)

We can do it all for you.

Lindner

Bahnhofstrasse 2994424 Arnstorf Germany Phone +49 (0)8723/20-0Fax +49 (0)8723/20-21 [email protected]

This document is the intellectual property of Lindner, Arnstorf (Germany). All the information contained in this brochure agrees with the information available at the time of its printing and only serves as advance information. Any possible colour deviations there might be from the original product are caused by printing-related reasons. Lindner is the sole and exclusive owner of the copyrights as well as the ancillary copyright. All use, and in particular any distribution, reprinting, exploitation or adaptation of this document shall only be allowed with express, written approval by Lindner.

TU

_D_B

/E/2

.2