Concepts Products Service...Class 0 tested to BS 476 part 6/7 Sound absorption tested to DIN EN ISO...
Transcript of Concepts Products Service...Class 0 tested to BS 476 part 6/7 Sound absorption tested to DIN EN ISO...
1
Applied Geometry.Lindner Post Cap Ceilings and Plafotherm® Post Cap Heated/Chilled Ceilings
Concepts
Products
Service
2
Building newsolutions.
Lindner undertakes major worldwide projects in all areas of interior finishes, insulation technology, industrial services and building facades. Frompre-planning through to project completion Lindner is your partner of choice.
The Company’s extensive manufacturing capability enables quality to be strictly maintained whilst allowing maximum flexibility to meet individual project requirements.
Environmental considerations are fundamental to all Lindner’s business principles.
Through partnerships with clients Lindner turns concepts into reality.
Choosing Lindner you have:Lindner Concepts:Tailored solutions specifically geared to satisfy individual project requirements
Lindner Products:Quality materials and systems to the very highest industry standards
Lindner Service:Comprehensive project management services
3
Main photo: Biocenter Copenhagen, Denmark© Weiles Fotografi
Central railway station Cologne, Germany
Lindner Post Cap ceilings are the solid foundation for partitioning your rooms. Visible and concealed post cap profiles can be installed to align with mullions, reflecting exterior architectural design in the interior. We offer a choice of systems with linear post caps and cross noggins as well as crossing boxes. Distances between post caps are variable.
Provided additional bracing is in place, Post Cap ceilings allow you to install partition walls in any direction and at any point in your room. Various customised options are available, e.g. radially installed post caps combined with trapezoidal ceiling panels.
Unmatched functionality and accessibility, ensured by Swing-Down mechanisms and a patented Drop-Slide option, make this ceiling a secure choice.
For outstanding comfort and pleasant room temperature we offer integrated Heating and Cooling Technologies for almost all products in this range. Post caps, crossing boxes and panels can be fitted with Lindner Lighting Systems.
Lindner Post Cap CeilingsStraightforward, robust and really high-profi le.
Customer benefits at a glance
- Variable spacing between the post caps or ceiling panels of different sizes- Fixing of partition walls to post cap profiles- Wide choice of perforations- Smoothly integrated Lindner Lighting Systems- Integrated Heating and Cooling Systems create a pleasant temperature
4
Post Cap CeilingsOur range.
System Page
LMD-B 100Linear Post Cap Ceiling Post Cap profiles visible, ceiling panels Lay-In, with Hook-On edge or with Fold-Down option
7
LMD-B 102Linear Post Cap CeilingPost Cap profiles visible, ceiling panels Lay-In or with Hook-On edge
8
LMD-B 110Post Cap Ceiling with Cross Noggins Post Cap profiles and Cross Noggins visible, ceiling panels Lay-In, with Hook-On edge or with Fold-Down option
9
LMD-B 111
Post Cap Ceiling with Cross Noggins and Crossing BoxesPost Cap profiles and Cross Noggins visible, Crossing Boxes for suspension, ceiling panels Lay-In, with Hook-On edge or with Fold-Down option
10
LMD-B 116Post Cap Ceiling with Cross Noggins Post Cap profiles visible, ceiling panels Lay-In or with Hook-On edge
11
LMD-B 117
Post Cap Ceiling with Cross Noggins and Crossing BoxesPost Cap profiles and Cross Noggins visible, Crossing Boxes for suspension, ceiling panels Lay-In, with Hook-On edge or with Fold-Down option
12
LMD-B 125Linear Post Cap CeilingPost Cap profiles visible, panels with Swing-Down opti-on on long side
13
LMD-B 137Linear Post Cap CeilingConcealed Post Cap profiles, removable ceiling panels
14
LMD-B 140Drop-Slide Post Cap CeilingPost Cap profiles visible, Drop-Slide panels
15
Aditional options Page
LMD-B .... SD Longitudinally sound-reduced ceilings 17
LMD-B .... Ceilings tested for stability in case of fire 18
Plafotherm® B Heated and Chilled Post Cap Ceiling 20-24
Lighting Lindner Lighting Systems 25
5
EN 13964
Central railway station Cologne, Germay
Abengoa Palmas Altas Campus, Spain
© Mark Bentley Photography
Bosch Karlsruhe, Germany
Standard requirements
Building material class A2-s1, d0tested to EN 13501-1Class A tested to ASTM E 84Class 0 tested to BS 476 part 6/7
Sound absorptiontested to DIN EN ISO 354ASTM C 423
Durability exposure class Atested to DIN EN 13964 table 7 and 8
Quality Standard
Light reflectance approx. 82 %Lindner RAL 9010, acc. to Lindner, plain
Material
Dimensions: ceiling panels, length up to 3,000 mm,width up to 1,250 mm, dependent on length,made of zinc-galvanised steel.Edges: square.Perforation: see Surface BrochureSubstructure: post cap manufactured from zinc-galvanised steel, profile roll-formed or bent with standard lengths of 100 mm, 125 mm, 150 mm and 200 mm, including corresponding suspension system. Special post cap widths can be delivered on request.Surface: electrostatically applied powder-coatingColour: RAL 9010, other colours in RAL and NCS available.Sound absorption: to improve sound absorption different perforations as well as a range of inlays are available.Relevant norms: DIN EN 10152/10327/13964, BS 2989, DIN EN ISO 12944, ASTM A 653
6
Siemens, Beijing
7
LMD-B 100 features post cap profiles in standard widths of 100, 125, 150 and 200 mm. If necessary, par-tition walls can be attached to the post cap profiles by means of additional bracings. However, this method is only possible with Type 1 or Type 2 ceiling panels.
Post Cap ceilings are maintenance-friendly and well-priced ceiling systems. Ceiling panels Type 1 (Lay-In), Type 2 (Lay-In with Hook-On edge) and Type 3 (Lay-In with Hook-On notch) may be used separately or in combination.
Standard requirements
Ceiling panels Material Post cap detail
LMD-B 100 Type 1
LMD-B 100 Type 2
LMD-B 100 Type 3
Ceiling panels Made of steel, powder-coated.Aluminium or stainless steel available on request
Length up to 3,000 mm, width up to 1,250 mm with LMD-B 100 Type 1/2, with LMD-B 100 Type 3 width depends on chosen length and is up to 625 mm
LMD-B 100 Type 1 Lay-InLMD-B 100 Type 2 Lay-In with Hook-On edgeLMD-B 100 Type 3 Lay-In with Hook-On notch
C-Post Cap
Available in all standard perforations
LMD-B 100 Type 1
LMD-B 100 Type 2
LMD-B 100 Type 3
Tried and tested, but never excelled.Linear Post Cap Ceiling – Post Cap profiles visible, removable ceiling panels, Lay-In or with Fold-Down option
LMD-B 100
8
Simply effective.Linear Post Cap Ceiling - Post Cap profiles visible, removable ceiling panels, Lay-In, with Hook-On edge or with Fold-Down option
LMD-B 102
Compared to other systems, LMD-B 102 with a standard post cap width of 100 mm proves to be one of our best-priced ceilings. The hangers are automatically secured against unintended loose-
ning from the post cap profiles due to a specially adapted design. Furthermore, it is environmentally-friendly due to savings of material.
Standard requirements
Ceiling panels Material Post cap detail
LMD-B 102 Type 1
LMD-B 102 Type 2
Ceiling panels Made of steel, powder-coated.Aluminium or stainless steel available on request
Length up to 3,000 mm, width up to 1,250 mm dependent on length
LMD-B 102 Type 1 Lay-InLMD-B 102 Type 2 Lay-In with Hook-On edge
G-Post Cap
Available in all standard perforations
LMD-B 102 Type 1
LMD-B 102 Type 2
9
Extends your options.Post Cap Ceiling with Cross Noggins – Post Cap profiles and Cross Noggins visible, removable ceiling panels, Lay-In or with Fold-Down option
LMD-B 110
This ceiling system consists of suspended linear post caps with attached cross noggins, both available in widths of 100, 125, 150 and 200 mm. Ceiling panels
are installed from above. As well as its pleasing visual LMD-B 110 scores with its option for partition connection in any direction along the post cap.
Standard requirements
Ceiling panels Material Post cap detail
LMD-B 110 Type 1
LMD-B 110 Type 2
LMD-B 110 Type 3
Ceiling panels Made of steel, powder-coated.Aluminium or stainless steel available on request
Length up to 3,000 mm, width up to 1,250 mm with LMD-B 110 Type 1/2, with LMD-B 110 Type 3 width depends on chosen length and is up to 625 mm
LMD-B 110 Type 1 Lay-InLMD-B 110 Type 2 Lay-In with Hook-On edgeLMD-B 110 Type 3 Lay-In with Hook-On notch
Linear Post Cap profiles and Cross Noggins
Available in all standard perforations
LMD-B 110 Type 1
LMD-B 110 Type 2
LMD-B 110 Type 3
10
Tightly crossed.Post Cap Ceiling with Cross Noggins and Crossing Boxes – Post Cap profiles visible, Crossing Boxes for suspension, removable ceiling panels
LMD-B 111
The distinct visual of this ceiling system is created with suspended crossing boxes and Hook-On cross noggins. Ceiling panels Type 1 (Lay-In), Type 2 (Lay-
In with Hook-On edge) and Type 3 (Lay-In with Hook-On notch) may be used separately or in combination.
Standard requirements
Ceiling panels Material Post cap detail
LMD-B 111 Type 1
LMD-B 111 Type 2
LMD-B 111 Type 3
Ceiling panels Made of steel, powder-coated.Aluminium or stainless steel available on request
Length up to 3,000 mm, width up to 1,250 mm with LMD-B 111 Type 1/2, with LMD-B 111 Type 3 width depends on chosen length and is up to 625 mm
LMD-B 111 Type 1 Lay-InLMD-B 111 Type 2 Lay-In with Hook-On edgeLMD-B 111 Type 3 Lay-In with Hook-On notch
Crossing Boxes and Cross Noggins with hitch technology
Available in all standard perforations
LMD-B 111 Type 1
LMD-B 111 Type 2
LMD-B 111 Type 3
11
Effective crossing.Post Cap Ceiling with Cross Noggins - Post Cap profiles visible, removable ceiling panels, Lay-In, with Hook-On edge or Fold-Down option
LMD-B 116
Standard requirements
Ceiling panels Material Post cap detail
LMD-B 116 Type 1
LMD-B 116 Type 2
Ceiling panels Made of steel, powder-coated.Aluminium or stainless steel available on request
Length up to 3,000 mm, width up to 1,250 mm dependent on length
LMD-B 116 Type 1 Lay-InLMD-B 116 Type 2 Lay-In with Hook-On edge
G-Post Cap and Cross Noggins
Available in all standard perforations
LMD-B 116 Type 1
LMD-B 116 Type 2
Compared to other systems, LMD-B 116 with a standard post cap width of 100 mm proves to be one of our best-priced ceilings. The hangers are automatically secured
against unintended loosening from the post cap profiles due to a specially adapted design. Furthermore, it is environmentally-friendly due to savings of material.
12
Comes in the most appealing dimensions.Post Cap Ceiling with Cross Noggins and Crossing Boxes – Post Cap profiles and Cross Noggins visible, Crossing Boxes for suspension, removable ceiling panels, either laid-in or with Hook-On notch
LMD-B 117
This system with post caps and cross noggins is a well-priced alternative to LMD-B 117. Post caps and cross noggins, available in standard widths of 100,
125, 150 or 200 mm, structure the ceiling. Hook-On ceiling panels and those with Hook-On notch or Hook-On edge can be combined.
Standard requirements
Ceiling panels Material Post cap detail
LMD-B 117 Type 1
LMD-B 117 Type 2
LMD-B 117 Type 3
Ceiling panelsMade of steel, powder-coated,Aluminium or stainless steelavailable on request
Length up to 3,000 mm, width up to 1,250 mm with LMD-B 117 Type 1/2, with LMD-B 117 Type 3 width depends on chosen length and is up to 625 mm
LMD-B 117 Type 1 Lay-InLMD-B 117 Type 2 Lay-In with Hook-On edgeLMD-B 117 Type 3 Lay-In with Hook-On notch
Crossing Box and Cross Noggin screwed
Available in all standard perforations
LMD-B 117 Type 1
LMD-B 117 Type 2
LMD-B 117 Type 3
13
Never loses its swing.Linear Post Cap Ceiling – Post Cap profiles visible, panels with Swing-Down option on long side
LMD-B 125
If frequent maintenance work is required, LMD-B 125 is the perfect match. The ceiling panels’ reliable swing-down mechanism makes it very easy to access the ceiling cavity. The mechanism can be operated single-handedly with a special tool to allow the
panel to swing down. An economically favourable combination of Swing-Down and Lay-In panels is possible.
Hinging and locking elements are protected by
DBGM.
Standard requirements
Ceiling panels Material Post cap detail
LMD-B 125 Type 1
LMD-B 125 Type 2
Ceiling panels Made of steel, powder-coated.Aluminium or stainless steel available on request
Length up to 3,000 mm, width up to 625 mm dependent on length
LMD-B 125 Type 1 without centre operationLMD-B 125 Type 2 with centre operation
C-Post Cap
Available in all standard perforations
14
Hidden powers.Linear Post Cap Ceiling – Concealed Post Cap profiles, removable ceiling panels
LMD-B 137
Concealed post caps of 100 mm in width designed with a centre groove, structure our LMD-B 137 ceilings. Partition walls may be fastened in these grooves. This system is very easy to handle in case
of maintenance works, because the ceiling panels are still removable, even if a partition wall is already fastened to the post cap.
Standard requirements
Ceiling panels Material Post cap detail
LMD-B 137 Type 1 Made of steel, powder-coated,Aluminium or stainless steelavailable on request
Length up to 3,000 mm, width up to 1,250 mm dependent on length
Concealed Post Cap with groove
Available in all standard perforations
LMD-B 137 Type 1
15
Patented accessibility.Drop-Slide Post Cap Ceiling, Drop-Slide Post Cap profiles visible, Drop Slide panels
LMD-B 140
The wall connection profiles and the post cap profiles of LMD-B 140 are made of aluminium. The ceiling panels can be dropped and then be slid in either direction along the aluminium post caps: Thus, there will be no dangling ceiling panels interfering with maintenance works.Furthermore, the wall connection profiles are able to compensate for tolerances. In standard configurati-on, you can choose between aluminium drop-slide hook-on profiles (width: 30 mm) joined back to back
and aluminium drop-slide post cap profiles (width: 150 mm).
System is protected by EP/DBP
and DBGM.
Standard requirements
Ceiling panels Material Post cap detail
LMD-B 140 Type 1 Ceiling panels Made of steel, powder-coated.Aluminium or stainless steel available on request
Length up to 3,000 mm, width up to 600 mm dependent on length
Aluminium Drop Slide Hook-On profiles joined back to back or aluminium Drop-Slide Post Cap profile
Available in all standard perforations.Minimum purchase quantity for alu-minium Post Cap profiles on request
Hook-On profiles joined back to back
Aluminium Drop-Slide Post Cap profile
16
Sound absorption Come to rest.
Rg – round holes in straight pitchRv – round holes arranged in diagonal pitch (60°)Rd – round holes arranged in diagonal pitch (45°)
Rg 0,7 - 1Hole diameter 0.7 mmopen area 1%valid for steel 0.6 mmacoustic tissue
w = 0.75SAA / s,m = 0.73NRC = 0.70
Rd 1,6 - 25Hole diameter 1.6 mmopen area 25 %valid for steel 0.6 mm acoustic tissue
w = 0.65 (L)SAA / s,m = 0.63NRC = 0.65
Rv 1,8 - 20Hole diameter 1.8 mmopen area 20 %valid for steel 0.6 mm acoustic tissue
w = 0.75 (L)SAA / s,m = 0.73NRC = 0.75
Rg 2,5 - 16Hole diameter 2.5 mmopen area 16 %valid for steel 0.6 mm acoustic tissue
w = 0.75 (L)SAA / s,m = 0.73NRC = 0.75
Rg 2,5 - 16Available with special tissue, to achieve sound absorption class B tested to DIN EN ISO 11 654
w = 0.80 (L)SAA / s,m = 0.81NRC = 0.80
Rg 3,0 - 17Hole diameter 3.0 mmopen area 17 %valid for steel 0.6 mm acoustic tissue
w = 0.70 (L)SAA / s,m = 0.69NRC = 0.70
Rv 3,0 - 20 Hole diameter 3.0 mmopen area 20 %valid for steel 0.6 mmacoustic tissue
w = 0.75 (L)SAA / s,m = 0.75NRC = 0.75
Example of the range of standard perforations available for ceilings without Heating and Cooling Technology.
Our Post Cap ceilings can be perforated in a variety of hole shapes and sizes. You will find other perforation options in our dedicated Surface Brochure. Depending on the choice of perforation the ceiling can become a highly effective acoustic barrier.
6.26.
2
2
22
2
3.83
3.323.32
5.5
5.5
5.5
5.5
6.5
6.5
So
un
d a
bso
rpti
on
coef
fici
ent
s�
0,00,20,40,60,81,0
Frequency in Hz125 500 1000 2000 4000250
So
un
d a
bso
rpti
on
coef
fici
ent
s�
0,00,20,40,60,81,0
Frequency in Hz125 500 1000 2000 4000250
So
un
d a
bso
rpti
on
coef
fici
ent
s�
0,00,20,40,60,81,0
Frequency in Hz125 500 1000 2000 4000250
So
un
d a
bso
rpti
on
coef
fici
ent
s�
0,00,20,40,60,81,0
Frequency in Hz125 500 1000 2000 4000250
So
un
d a
bso
rpti
on
coef
fici
ent
s�
0,00,20,40,60,81,0
Frequency in Hz125 500 1000 2000 4000250
0.00.20.40.60.81.0
125 500 1000 2000 4000250
So
un
d a
bso
rpti
on
coef
fici
ent
s�
Frequency in Hz
So
un
d a
bso
rpti
on
coef
fici
ent
s�
0,00,20,40,60,81,0
Frequency in Hz125 500 1000 2000 4000250
6,5
5,5 5,5
17
Longitudinally sound-reduced ceilings
Today, modern buildings are expected to satisfy high demands. Design, performance, security and flexibility as well as long-term profitability must be granted. Furthermore, rooms have to make the people therein feel comfortable. All this can be accomplished by using longitudinally sound-reduced Lindner ceilings available with a range of different inlays. It goes without saying that we always provide for our ceiling panels to be easy to remove in case of maintenance works.
LMD-B 100 SD Lay-In sandwich elements Dn,f,w = 49 dB without barrier
LMD-B 101 SD Hook-On sandwich elements Dn,f,w = 49 dB without barrier
LMD-B 129 SD1)Lay-In/Swing-Down sandwich elements, fastening of partition walls in Post Cap grooves
Dn,f,w = 48 dB without barrier
LMD-B 137 SD1)Lay-In sandwich elements, fastening of partition walls in joints
Dn,f,w = 48 dB without barrier
LMD-B 138 SD1)Swing-Down sandwich elements, fastening of partition walls in joints
Rw = 40 dB * with barrier
LMD-B 100 SD, LMD-B 101 SD LMD-B 129 SD
LMD-B 137 SD LMD-B 138 SD
Rated normalised flanking level differenceDn,f,w laboratory-tested according to currently applicable standards* tested on site according to DIN EN ISO 140-4
1) Minimum purchase quantity for post cap profiles on request
18
LMD-B 100
Classification: RF15 according to Belgian standard NBN 713-020
Panel dimensions:Maximum length: 3,000 mmMaximum width: 397 mmConstructional height of ceiling element: 50 mm
Test Reference No: 11934
Post Cap ceiling
LMD-B 101(LMD-B 200)
Classification: RF45 according to Belgian standard NBN 713-020
Panel dimensions:Maximum length: 3,180 mmMaximum width: 600 mmConstructional height of ceiling element: 50 mm
Test Reference No: 10840
Post Cap ceiling
LMD-B 119
Classification: SF15 according to French standard Arrêté du 3 août 1999 et son annexe II
Panel dimensions:Maximum length: 1,250mmMaximum width: 675 mmConstructional height of ceiling element: 30 mm
Test Reference No: RS 00-205/A
Post Cap ceiling
LMD-B 132
Classification: SF15 according to French standard Arrêté du 3 août 1999 et son annexe II
Panel dimensions:Maximum length: 770 mmMaximum width: 1,735 mmConstructional height of ceiling element: 40 mm
Test Reference No: RS 02-033/C
Post Cap ceiling with Swing-Down option
LMD-B 134
Classification: RF30 according to Belgian standard NBN 713-020
Panel dimensions:Maximum length: 2,000 mmMaximum width: 1,200 mmConstructional height of ceiling element: 62.5 mm
Test Reference No: 3446/2221 – Kra + 2010-A-033
Longitudinally sound-re-duced Post Cap ceiling
Ceilings tested for stability in case of fi re
Metal ceilings not only have to meet requirements for an impeccable appearance and good acoustic proper-ties but also for the adherence to safety requirements in case of fire. For this reason, the use of non-com-bustible components and to assure the stability of the ceiling in case of fire can be seen as decisive factors. Lindner ceiling systems show a high level of residual strength in spite of an exposure to high temperatures.
This compilation contains ceiling systems especially developed for specific projects. These ceiling systems may only be offered after having consulted our R&D Department!
19
FC Bayern Munich
20
Plafotherm® B
The integrated Heating and Cooling Technologies of Plafotherm® B create a pleasant temperature for any living and working environment. The tried and tested post cap system ensures safe handling. We will be glad to give your metal ceiling a distinctive look by applying one of our many eye-catching Lindner surfaces.
Longitudinally sound-reduced Plafotherm® B ... SD Heated/Chilled ceilings provide for utmost flexibility when it comes to changing the floor plan in the sim-plest way. For this reason, these ceilings are in many cases installed in combination with movable partition walls. The heating and cooling system is particularly suitable to ensure room-to-room sound absorption as it may provide for excellent longitudinal sound re-duction values between 43 dB and 62 dB, depending on the construction.
Post Cap at its best.Heated and Chilled Post Cap Ceilings
21
Range
System
Plafotherm® B 100Linear Heated and Chilled Post Cap Ceiling Post Cap profiles visible, ceiling panels Lay-In, with Hook-On edge or with Fold-Down option
Plafotherm® B 110
Heated and Chilled Post Cap Ceiling with Cross Noggins Post Cap profiles and Cross Noggins visible, ceiling panels Lay-In, with Hook-On edge or with Fold-Down option
Plafotherm® B 111
Heated and Chilled Post Cap Ceiling with Cross Noggins and Crossing BoxesPost Cap profiles and Cross Noggins visible, Crossing Boxes for suspension, ceiling panels Lay-In, with Hook-On edge or with Fold-Down option
Plafotherm® B 117
Heated and Chilled Post Cap Ceiling with Cross Noggins and Crossing BoxesPost Cap profiles and Cross Noggins visible, Crossing Boxes for suspension, ceiling panels Lay-In, with Hook-On edge or with Fold-Down option
Plafotherm® B 125Linear Heated and Chilled Post Cap CeilingPost Cap profiles visible, panels with Swing-Down option on long side
Plafotherm® B 137Linear Heated and Chilled Post Cap CeilingConcealed Post Cap profiles, removable ceiling panels
Plafotherm® B 100 SDLinear Heated and Chilled Post Cap Ceiling, longitudi-nally sound-reducedLay-In sandwich elements
Plafotherm® B 137 SD
Linear Heated and Chilled Post Cap Ceiling, longitudi-nally sound-reducedLay-In sandwich elements, fastening of partition walls in joints
EN 13964 Quality Standard
Building material class A2-s1, d0tested to EN 13501-1
Sound absorptiontested to DIN EN ISO 354ASTM C 423
Durability exposure class Atested to DIN EN 13964 table 7 and 8
Heating capacity to DIN EN 14037Cooling capacity to DIN EN 14240
Standard requirements
Light reflectance approx. 82 %Lindner RAL 9010 acc. to Lindner, plain
22
Technical details
Heating/Cooling Technology:Made of aluminium heat conducting profile with copper meanders, integrated into ceiling panel for thermal conductivity.
Heat conducting profile: aluminium profile, with standard widths of 60, 80 and 120 mmCopper meanders: copper coil, 12x0.5 or 12x0.75 mmWater volume: approx. 1 l/m²Tube distance: 80 - 150 mm
Recommended operation dataFlow temperature (cooling) 15 – 17 °CTemperature spread 2 – 4 KFlow temperature (heating) 30 – 35 °CTemperature spread 4 – 6 KRecommended pressure drops 25 – 30 kPa
Reactive capability curve
6,0 8,0 10,0 12,0 14,020
40
60
80
100
140
120
160
180
200
Sp
ecif
ic c
apac
ity
[W/m
²]
Excess or insufficient temperature [K]
CoolingHeating
DimensioningThe potential of innovative Heating and Cooling Technologies can be fully tapped by the use of project specific dimensioning. Trust in the experience of our experts, who will be pleased to carry out the dimensio-ning for your project.
DevelopmentOur products with Heating and Cooling Technologies have been developed to satisfy the demands of nati-onal and international markets. Our in-house sound laboratory uses highly sensitive measuring devices to test acceptable sound pressure levels for the Heating and Cooling Technologies. The heating and cooling performance of our systems are continuously opti-mised using test results of our own climate chamber which is officially accredited.
ServiceAs every hydraulic pipework of the building services the Heated/Chilled Ceiling has to be flushed, to protect the valves and the entire pipework system must be checked for leaks, using a pressure test, before the system is put into operation. For maximum operational reliability, we check the smooth flow for all meanders by means of state-of-the-art infrared camera systems with image recording of the tested zones. After the start of operation, you will receive the documentation of the pressure and flush checks as well as the thermography report confirming complete functionality of your Heated and Chilled Ceiling.
Determination of excess and insufficient temperatureTK = R – ( VL + RL)/2TH = ( VL + RL)/2 – R
TK = insufficient temperature (cooling) [K]TH = excess temperature (heating) [K]R = room temperature [C°]VL = flow temperature [C°]RL = return-flow temperature [C°]
Nominal cooling capacity according to DIN EN 14240 (10K) 103.3 W/m²
Nominal heating capacity according to DIN EN 14037 (15K) 118.4 W/m²
23
Sound absorption
Rg 0,7 - 1hole diameter 0.7 mmopen area 1 %acoustic tissuemineral wool lining
w = 0.35 (L)SAA / s,m = 0.41NRC = 0.40
Rv 1,8 - 20hole diameter 1.8 mmopen area 20 %acoustically effective heat conducting profileacoustic tissuemineral wool lining
w = 0.50 (L)SAA / s,m = 0.64NRC = 0.65
Rv 1,8 - 20hole diameter 1.8 mmopen area 20 %acoustically effective heat conducting profile acoustic tissue
w = 0,70 (L)SAA / s,m = 0,74NRC = 0,75
Rv 2,0 - 20hole diameter 2.0 mmopen area 20 %acoustic tissuemineral wool lining
w = 0.55 (LM)SAA / s,m = 0.69NRC = 0.70
Rg 2,5 - 16hole diameter 2.5 mmopen area 16 %acoustic tissuemineral wool lining
w = 0.50 (L)SAA / s,m = 0.64NRC = 0.65
Example of the range of standard perforations available for Heated/Chilled Ceilings, measured at maximum occupancy.
As a matter of course, we build your Heated/Chilled Ceiling according to your requirements concerning the acoustic performance. Our wide range of perforation patterns not only improves sound absorbing properties but also the appearance of your metal ceiling. We measure the sound absorption at maximum occupancy with heat conducting profiles.
6,2
6,2
5.5
5.5
4.3
3.72 3.72
So
un
d a
bso
rpti
on
coef
fici
ent
s�
0,00,20,40,60,81,0
Frequency in Hz125 500 1000 2000 4000250
So
un
d a
bso
rpti
on
coef
fici
ent
s�
0,00,20,40,60,81,0
Frequency in Hz125 500 1000 2000 4000250
So
un
d a
bso
rpti
on
coef
fici
ent
s�
0,00,20,40,60,81,0
Frequency in Hz125 500 1000 2000 4000250
Rg – round holes in straight pitch, Rv – round holes arranged in diagonal pitch (60°), Rd – round holes arranged in diagonal pitch (45°)
Sch
alla
bso
rp-
tio
nsg
rad
0,00,20,40,60,81,0
Frequenz Hz125 500 1000 2000 4000250
Sch
alla
bso
rp-
tio
nsg
rad
0,00,20,40,60,81,0
Frequenz Hz125 500 1000 2000 4000250
Plafotherm® B 100 SD Dn,f,w = 48 dBLay-in sandwich elements,without barrier
Plafotherm® B 100 SD Dn,f,w = 62 dBLay-in sandwich elements,with barrier
Plafotherm® B 137 SD Dn,f,w = 48 dBLay-in sandwich elements,without barrier
Longitudinally sound-reduced
24
Hydraulic components
Multifunctional regulation unitThe multifunctional regulation unit is ideal for heated and chilled ceiling systems. It consists of a multifunctional ball valve, a control valve with adjustable drive, system distributor, air-bleeding system and various connecting elements. This multifunctional ball valve makes it very easy to flush out and bleed the control zones independently of the main system. This means that the chilled ceiling can be maintained independently from other building trades.
Connection hoses and fittingsHigh-grade steel hoses are oxygen impermeable, tested to DIN 4726, and are used as connection hoses. These hoses are perfectly suited to accept a large number of fittings. A system distributor with three outgoing lines completes the system.
Multilayer composite (MV) pipe systemThe MV pipe system is oxygen impermeable as perDIN 4726 and includes an MV system distributor with twoand three outlets, MV clamped screw connection and special MV pressing transmission to which to fit the heating and cooling pipework.
Copper pipe systemFor main and distribution pipes, we offer high-quality, current-tested conduits made of copper as per EN 1057and fittings as per EN 1254.
For perfect heating and cooling connections, Lindner provides a great number of hydraulic components and accessory parts.
Advantages: - Tested system- One-stop solutions- Ideal for heating/cooling systems- Maintained independently from other building trades
25
Integration is our passion!The combination of ceiling and light produces a well-rounded and functional visual effect.
Lindner Lighting systems
Type B 20 / B 25System Light for modular ceiling, the luminaries are installed between the ceiling panels. Construction (B 20) with aluminium cap, adapted for workstation lighting according to EN 12464 -1. Optimised louvre technology by means of above closed cross blades as well as the consistent use of reflection-strengthe-ned MIRO aluminium. Alternative construction with opal acrylic glass cover (Type B 25).
Technical detailsVoltage: 220-240 Volt / 50-60 HzProtection class: 1Protective system: IP 20Ballast: electronic ballastFinish: reflector grid/opal acrylic glassColour: available to mach ceiling panelsIlluminant: on site
Type L 100Lighting channel for continuous arrangement. The lighting system is an integral part and supporting element of the Lindner metal ceiling, thereby ensuring perfect alignment within the shortest possible installation time.
Technical detailsVoltage: 220-240 Volt / 50-60 HzProtection class: 1Protective system: IP 20Ballast: electronic ballastFinish: mirror grid or satin acrylic glass coverColour: available to mach ceiling panels 100
70
125
65
26
Each one’s a specialist. Perforation range for our post caps
Post Cap options
General layout options
Standard C-post cap
Partition wall attachment requires additional bracing
C-post cap with 9 or 13 mm centre groove
C-shadow gap post cap
Lay-In post cap
Installation possibilities
100125150
100 Standard
100
Diagonalbracing
27
Aluminium Drop-Slide post cap for LMD-B 140width: 150 mm
Metal ceiling suspended with lowerable and movable ceiling panels
Post cap for reduced ceiling to soffit height
Post cap directly fi xed with compensation bracket to concrete ceiling
Removable post cap
Hook-on metal ceiling panels with lay-in post cap. After removal of the post cap, the partition wall can be installed
directly to the concrete ceiling.
Concealed post cap
Hook-on ceiling with removable and concealed post cap. Having removed the removable post cap, the partition wall
can be attached to the concealed post cap.
Acousticbarrier
Removable and concealed post cap
Installation possibilities
38 -
50
mm
100
150
28
Accurately separated.The visual of the ceiling system can be influenced by a selection of different joint designs. Standard panels come with C-shaped edges on long sides. By selecting C-Z-shaped edges the longitudinal and cross axes are overlapped; the joint appearing to be closed. Determine your choice of joint width by ordering panels with different spacers.
Joint designs
panel width panel width~3
panel width panel width~3
panel width panel widtheither 3, 8 or 10 mm
panel width panel widthpanel length
~5
Gasket filled joint
Butt joint
Joint with embossed panel turn-up
Panel abutment with joint and spacer
Panel abutment with spacer for open joint
Bevelled butt joint
5-8
5-8
panel width panel width panel width panel width
~7-15 mm
29
Further wall connections available on request.
Steel L-perimeter trim hold-down clip, visible width: 25 mm
Aluminium L-perimeter trim with hold-down function hold-down sheetvisible width: 25 mm
pillar semiringcurved L-trimvisible width: variable
Steel shadow gap trimvisible width: 20 mm, shadow gap width: 20 mm
Aluminium shadow gap trim with hold-down functionhold-down sheetvisible width: 25 mm, shadow gap width: 20 mm
pillar semiringcurved shadow gap trimvisible width: 25 mm, shadow gap width: 20 mm
Wall connections can be realised in different ways - with and without shadow gap. To ensure that cut panels rest entirely on the trim´s supporting surface without any corrugation, hold-down clips and sheets are applied. Specially designed aluminium L-perimeter and shadow gap trims for columns provide for a clean connection to curved shapes.
Wall connectionsThe link between ceiling and wall.
30
ARTlineSTYLEline
To create a top of the range visual effect your metal ceiling is available with a choice of ARTline/STYLEline wood surfaces. The wood surfaces are also available tested to ASTM E 84 class A, regarding fire behaviour of surfaces.
GRAPHICline
GRAPHICline permits to apply any desired pattern colour-fast, gloss-fast and light-fast, with a photo-realistic resolution of up to 1,200 dpi, to a great variety of surface textures and materials. All colours and images may be printed on panels of any desired size.
INOXlook
Lindner aluminium ceilings can be supplied with stainless steel appearance. The INOXlook surface is created by special rolling and anodising processes and is similar to a brushed stainless steel surface (grain 180). Aluminium manufactured to EN 485-4 and EN 573-3, anodised to EN 12373.
Meteo
We protect the substructure and surface of our systems against corrosion to allow them to be installed in external areas, swimming pools and underground car parks. The anti-corrosion coating Meteo is tested to EN 13964 table 8 / DIN 55928 part 8 / DIN EN ISO 12944.
AntiBac
We offer substructure and surface coating with our antibacterial finish for areas with enhanced hygienic requirements. The performance of AntiBac is tested to JIS Z 2801:2000.
Mutex
The structured surface of Mutex combines the visual characteristics of an unperforated but sound absorbing ceiling with the unique choice of a perforated metal ceiling. Mutex is tested to ASTM E 84 class A and also available as building material class A2-s1, d0 tested to DIN EN 13501-1.
Other surface options available.
Specialties Our surfaces – unrivalled choice.
31
Specifications for tenders Guidelines
Request specifications for tenders by contacting us on:Phone +49 (0)8723/20-36 96Fax +49 (0)8723/20-26 90e-mail: [email protected] visit us on the internet at www.Lindner-Group.com.
Installation guidelines:All published information is in accordance with existing DIN and EN Standards and other relevant regulations. Lindner production conforms to Quality Management Certificate DIN EN ISO 9001 and is also certified by TÜV Management. The best visual result and performance of the ceiling will be achieved if installation is carried out in appropriate working conditions and with the utmost care.
Installation conditions:Installation of the substructure should only be started if the preliminary services are at a stage where it is safe and efficient to commence. The ceiling should only be installed when the room is dry and sealed, all wet trades are finished and all external glazing and doors are installed. Differing parameters may be necessary depending on the individual project. During the installation of the ceiling, room temperatures of 10-25°C should be ensured.
Service:Technical information and documents (product sheets with guide specifications and installation instructions, test certificates, samples etc.) are available on request. We gladly offer comprehensive consulting services, for example specific building authority needs.
32
Lindner Concepts:
- Insulation Engineering and Industrial Service- Clean Rooms and Laboratories- Airports and Airlines- Railways and Tunnels- Studios and Concert Halls- Interior Fit-out and Furnishings- Cruise Liner and Ship Fit-out- Hotels and Resorts- General Contracting
Lindner Products:
- Facades- Ceiling Systems- Lights and Lighting Systems- Partition Systems- Doors- Floor Systems- Heating and Cooling Technologies- Dry Lining Systems
Lindner Service:
- Green Building- Deconstruction and Gutting- Clearance of Harmful Substances- Research and Development- Delivery- General Planning- Installation- Maintenance- Public-Private Partnership (PPP)
We can do it all for you.
Lindner
Bahnhofstrasse 2994424 Arnstorf Germany Phone +49 (0)8723/20-0Fax +49 (0)8723/20-21 [email protected]
This document is the intellectual property of Lindner, Arnstorf (Germany). All the information contained in this brochure agrees with the information available at the time of its printing and only serves as advance information. Any possible colour deviations there might be from the original product are caused by printing-related reasons. Lindner is the sole and exclusive owner of the copyrights as well as the ancillary copyright. All use, and in particular any distribution, reprinting, exploitation or adaptation of this document shall only be allowed with express, written approval by Lindner.