Concepts for New Recycler Lambertons
GW Foster
Dec 2000
Concepts for New Recycler Lambertons
GW Foster Dec 2000
YOU CAN NEVER BE:
• Too Thin
• Too Rich
• Have too much Aperture
for Beam Transfers
Lambertson Challenges
• Septum Width– Lamination die ~2x material
~0.125”
• Septum Straightness– Stacking– Overall Warpage
• Vacuum– Laminations have large area– Iron Rusts
• Bend Field– Iron Limit ~1 T– Perm. Mag. (Ferrite) Limit ~0.5T
Recycler Lambertson
Recycler LambertsonField Map
Recycler Lambertson Specifications
Specific Problems with Recycler Lambertsons
• Brick Trim of field shape (skew quad) not exact– ~1% skew quad field defect
• Gun Boring of Field-free region not very precise– Effective Septum Width ~0.2”– Septum extremely thin some
places
• Vacuum problems required Stainless beam pipe insert
• Overall Septum Width ~0.3”
Trimming Skew Quad With Side Brick Position
Lambertson Field Defects vs. Side Brick Position
-200
-100
0
100
200
300
400
500
600
0 0.25 0.5 0.75 1
Side Brick Overhang Distance Below Pole Tip Surface (in.)
Cal
cula
ted
Fie
ld D
efec
t (
un
its
at 1
")
Calc. Skew Quad
Calc. Skew Octupole
As-Built (approx)
New Lambertson Concepts
• Copper-Plated Steel to solve vacuum problems– (Suggested by Helen Edwards)
• Vacuum Shell: either– Brazed Connections to Stainless– Thin Stainless Skin on Insert
• Separates Vacuum & Septum design from Structure & Magnetics.
Copper Plated Steel
Field Free Region
BendRegion
Stainless Vacuum Bridge
BrazeJoints
New LambertsonSeptum And Vacuum Pipe
Welded Stainless Skin Option
Vacuum Flange at Ends(Brazed or Welded)
Pole Tip For Permanent Magnet
Machined Steel Base Plate for Lambertson
Permanent Magnet Ferrite(3 Layers for B~0.3T)
Steel Cover Plates
New Recycler Lambertson?