Compton polarimeter for EIC Alexandre Camsonne. Comments from report The requirements for...

39
Compton polarimeter for EIC Alexandre Camsonne

Transcript of Compton polarimeter for EIC Alexandre Camsonne. Comments from report The requirements for...

Page 1: Compton polarimeter for EIC Alexandre Camsonne. Comments from report The requirements for bunch-to-bunch accuracy of the polarization measurement are.

Compton polarimeter for EIC

Alexandre Camsonne

Page 2: Compton polarimeter for EIC Alexandre Camsonne. Comments from report The requirements for bunch-to-bunch accuracy of the polarization measurement are.

Comments from report• The requirements for bunch-to-bunch accuracy of the polarization

measurement are essential,but have not been specified. An evaluation of rates and the development of a scheme, which satisfies the requirements for bunch-to-bunch accuracy of the polarization measurement, are essential. A further study of the backgrounds and efforts to find ways how to reduce it, have a high priority.

• The committee considers a high-quality polarization-measurement program essential for EIC and supports the idea of a “Compton polarimeter test bed”. It recommends that the detailed requirements on polarization knowledge be worked out and the resulting detector specifications evaluated, for both EIC machine designs. A close contact between the other groups working on EIC polarization and the machine experts from both EIC machine designs is strongly encouraged.

Page 3: Compton polarimeter for EIC Alexandre Camsonne. Comments from report The requirements for bunch-to-bunch accuracy of the polarization measurement are.

ERHIC• 6.6 GeV to 21.2

GeV • 9.4 MHz Repetion

rate• Up to 21

recirculations• 50 mA with

“gatling gun” design

• 80 % min polarization

• Similar to CEBAF

Vadim PtitsyneRHIC Accelerator DesignEIC2014

Page 4: Compton polarimeter for EIC Alexandre Camsonne. Comments from report The requirements for bunch-to-bunch accuracy of the polarization measurement are.

MEIC

• Storage ring – Ring ring• 748.5 MHz = 1.33 ns bunch

structure• 3 A at 3 GeV and 180 mA at 11

GeV• 2 macrobunch with one

polarization 2.3 us• Measure polarization average

of the two macrobunch• Every electron bunch crosses

every ion bunch

Warm large booster(up to 25 GeV/c)

Warm 3-12 GeV electron collider ring

Medium-energy IPs withhorizontal beam crossing

Injector

12 GeV CEBAF

Pre-boosterSRF linac Ion

source

Cold 25-100 GeV/cproton collider ring

Three Figure-8 rings stacked vertically

Electron cooling

Page 5: Compton polarimeter for EIC Alexandre Camsonne. Comments from report The requirements for bunch-to-bunch accuracy of the polarization measurement are.

Compton asymmetrye + g e’ + g’

s( ) e + g e’ + g’

s( )

)

Page 6: Compton polarimeter for EIC Alexandre Camsonne. Comments from report The requirements for bunch-to-bunch accuracy of the polarization measurement are.

Low Q2 chicane and Compton

Compton detectors

Low Q

2 chica

ne

Page 7: Compton polarimeter for EIC Alexandre Camsonne. Comments from report The requirements for bunch-to-bunch accuracy of the polarization measurement are.

MEIC beam parameters

F. Lin --- ---

Beam energy Gev 3 5 6 7 9 11

Beam current A 3 3 2.0 1.1 0.4 0.18

Total SR power MW 0.49 3.82 5.28 5.38 5.35 5.37

Linear SR power density kW/m 1.02 7.87 10.88 11.08 11.01 11.06

Energy loss per turn MeV 0.17 1.27 2.64 4.89 13.37 29.84

Energy spread 10-3 0.34 0.56 0.68 0.79 1.01 1.24

Longitudinal damping time ms 83.6 18.1 10.4 6.6 3.1 1.7

Page 8: Compton polarimeter for EIC Alexandre Camsonne. Comments from report The requirements for bunch-to-bunch accuracy of the polarization measurement are.

MEIC Bunch Structure In Collider Ring

8

… …… …

Empty buckets1.33ns 748.5MHz

Polarization (Up) Polarization (Down)

bunch train & polarization pattern in the collider ring

Empty buckets

2.3μs, ~1700 bunches 2.3μs, ~1700 bunches

Page 9: Compton polarimeter for EIC Alexandre Camsonne. Comments from report The requirements for bunch-to-bunch accuracy of the polarization measurement are.

MEIC Bunch Pattern for Continuous Injection

9

duty factor 6.9e-4

……

100 ms (~4 damping time) 1s, , Iave=6μA

Macro bunch train

Detector duty factor 0.98

duty factor 4.3e-4……

1.33 ns, 748.5 MHz 173.5 pC

2.3μs, ~1700 bunches

173.5 pC1.33 ns, 748.5 MHz

2.3μs, ~1700 bunches

……

duty factor 0.0167

……60s

Iave=100 nA

1 second

At 100nA average injected current, Pequ/P0> 96% for the whole energy range

Page 10: Compton polarimeter for EIC Alexandre Camsonne. Comments from report The requirements for bunch-to-bunch accuracy of the polarization measurement are.

Time structure

• Bunch to bunch : 1.33 ns• Polarization state : 2.3 us• Top off : 1 min

• Measure asymmetry for one laser state and polarization

• Can generate more macro bunches for systematics check, time max for measurement is 2.3 us

+3.7 us

-3.7 us

Page 11: Compton polarimeter for EIC Alexandre Camsonne. Comments from report The requirements for bunch-to-bunch accuracy of the polarization measurement are.

A. Camsonne EIC Users meeting

11

ERHIC• 5 GeV to 21.2 GeV • 10.8 MHz

Repetition rate• 50 mA with

“Gatling gun” design up to 24 sources

• Need to measure each sources polarization

• 80 % min polarization

• Similar recirculation to CEBAF6/27/2014

Page 12: Compton polarimeter for EIC Alexandre Camsonne. Comments from report The requirements for bunch-to-bunch accuracy of the polarization measurement are.

eRHIC beam parameters

• 50 mA with up to 20 sources• 10.8 MHz repetition rate• ERL LINAC allows helicity structure with helicity

flip from the source• Need individual measurement of each source

– 100 ns max for each measurement– Logic signal to flag which source is recorded

• Rates sufficient to measure all sources in a few minutes

Page 13: Compton polarimeter for EIC Alexandre Camsonne. Comments from report The requirements for bunch-to-bunch accuracy of the polarization measurement are.

EIC R&D Meeting July 2014 13

Reasons why polarization / Current CAN vary From Bunch to Bunch

E.C. Aschenauer

Polarisation:Hadrons in a storage ring:source instabilitiesBeam-Beam effectsbunch-to-bunch emittance variation, Characteristic scale can be seen from AGSRHIC polarization profile variation for different bunches after accelerationleptons in a storage ring:Beam-Beam effectssource instabilities

leptons in eRHIC What is the expected fluctuation in polarisation from cathode to cathode in the gatling gun

from Jlab experience 3-5% Is there the possibility for a polarization profile for the lepton bunches

if then in the longitudinal direction can be circumvented with 352 MHz RF

Current:Hadrons & leptons in a storage ring:Variations in transfer efficiency from pre-accelerator to main ring beam-beam interaction is important, it affects the bunch lifetime during the storeleptons in eRHIC What fluctuation in bunch current for the electron do we expect

limited by Surface Charge, need to see what we obtain from prototype gun

Requirement:

measure polarisation with enough statistical precision in sufficiently short time

units to monitor polarisation as function of time and parameters influencing

polarisation

hadron and lepton polarimetry are critical

Page 14: Compton polarimeter for EIC Alexandre Camsonne. Comments from report The requirements for bunch-to-bunch accuracy of the polarization measurement are.

EIC R&D Meeting July 2014 14E.C. Aschenauer

Technology: Compton Back scattering measure photon and lepton complementary & redundancy

e-Polarimeter location at IP

overlap of bremsstrahlungs and compton photons only possible if we have number of empty p-bunches = # cathods in gatling gun

luminosity loss before/after IP need to measure at location spin is fully longitudinal or transverse

1/6 turn should rotate spin by integer number of π segmented Calorimeter longitudinal polarization Energy asymmetry transverse polarization component position asymmetry

After IP: does collision reduce polarization problem at ILC for eRHIC very small need to measure at location, where bremsstrahlung contribution is small

Before IP: need to find room for photon calorimeter

Introduce dog-leg for polarimeter minimizes bremsstrahlungs photon impact creates synchroton radiation

Other considerations: # of cathods in gatling gun: golden number is 20

This guarantees that a hadron bunch collides always with electrons produced from one particular cathode, avoiding/reducing significantly harmful beam-beam effect of electron beam parameter variations on the hadrons

eRHIC lepton polarimeter

Page 15: Compton polarimeter for EIC Alexandre Camsonne. Comments from report The requirements for bunch-to-bunch accuracy of the polarization measurement are.

Compton rates

• Green laser, 1.3 degrees crossing angle• beam 350 um

Energy Rate ( kHz/W/A)

Max current (A)

Rate kHz/W

eRHICcurrent (A)

Rate(kHZ/W)

3 316 3 948 0.05 15.85 298 3 894 0.05 14.96 290 2 580 0.05 14.57 283 1.1 311.3 0.05 14.19 269 0.4 107.6 0.05 13.4

11 258 0.18 46.44 0.05 12.9

•laser of a few watts : 10 KHz to 1 MHz - sufficent statistics in a few seconds•1000 W cavity : rates from tens of KHz to MHz level ( if background high )

Page 16: Compton polarimeter for EIC Alexandre Camsonne. Comments from report The requirements for bunch-to-bunch accuracy of the polarization measurement are.

Compton polarimetry requirements

Page 17: Compton polarimeter for EIC Alexandre Camsonne. Comments from report The requirements for bunch-to-bunch accuracy of the polarization measurement are.

Compton polarimeter in low-Q2 chicane

Same polarization as at the IP due to zero net bend

Non-invasive continuous polarization monitoring

Polarization measurement accuracy of ~1% expected

No interference with quasi real photon tagging detectors

c

Laser + Fabry Perot cavity

e- beam

Quasi-real high-energy photon tagger

Quasi-real low-energy photon tagger

Electrontracking detector

Photon calorimeter

Electron detector implementation in low Q2

D = -22.4 cmD’ = -0.04 At 10 GeV assume D = 5 mCompton edge : 2.6 GeV = 5.8 cm +0.0104*L = 10.84 cmZero crossing 1.514 GeV = 3.39 cm + 0.006*L = 6.39 cm

D = 10 mCompton edge = 16.2 cmZero crossing = 9.39 cm

Page 18: Compton polarimeter for EIC Alexandre Camsonne. Comments from report The requirements for bunch-to-bunch accuracy of the polarization measurement are.

Chicane • Different type of magnet for• dipole 1 and 4 can be C magnets• Dipole 2 and 3 can be C magnets in other direction or

open dipoles• New design going from 15 m to 30 m

c

Laser + Fabry Perot cavity

e- beam

Quasi-real high-energy photon tagger

Quasi-real low-energy photon tagger

Electrontracking detector

Photon calorimeter

Beam size shrinks with distance to interaction point : reduction of halo in detector

Page 19: Compton polarimeter for EIC Alexandre Camsonne. Comments from report The requirements for bunch-to-bunch accuracy of the polarization measurement are.

Simulation• Simulation Dave Gaskell ( small aperture )

15 meter setup

Photon

Electron

• Very sensitive to Halo• Simulation for cavity

design

Page 20: Compton polarimeter for EIC Alexandre Camsonne. Comments from report The requirements for bunch-to-bunch accuracy of the polarization measurement are.

Simulation• Simulation Dave Gaskell ( large aperture )

15 meters setup

Photon

Electron

Page 21: Compton polarimeter for EIC Alexandre Camsonne. Comments from report The requirements for bunch-to-bunch accuracy of the polarization measurement are.

Hall A Compton chicane

Vertical motion of electron detector to move detector close to the beam( up to 5 mm )Photon

detector on movable table

Page 22: Compton polarimeter for EIC Alexandre Camsonne. Comments from report The requirements for bunch-to-bunch accuracy of the polarization measurement are.

Roman pot technique evaluation in Compton test stand

• Need to evaluation contribution of window

• Evaluate gain in cabling complexity with full vacuum solution

Page 23: Compton polarimeter for EIC Alexandre Camsonne. Comments from report The requirements for bunch-to-bunch accuracy of the polarization measurement are.

Photon detector Synchrotron radiation study

(Mike Sullivan)

Page 24: Compton polarimeter for EIC Alexandre Camsonne. Comments from report The requirements for bunch-to-bunch accuracy of the polarization measurement are.

Beam pipe

X-ray reduction

Page 25: Compton polarimeter for EIC Alexandre Camsonne. Comments from report The requirements for bunch-to-bunch accuracy of the polarization measurement are.

Sloped beam pipe

Need <10 W / mm

Page 26: Compton polarimeter for EIC Alexandre Camsonne. Comments from report The requirements for bunch-to-bunch accuracy of the polarization measurement are.

Synchrotron radiation in detector with different shieldings 5 GeV

Page 27: Compton polarimeter for EIC Alexandre Camsonne. Comments from report The requirements for bunch-to-bunch accuracy of the polarization measurement are.

Synchrotron radiation in detector with different shieldings 11 GeV

Page 28: Compton polarimeter for EIC Alexandre Camsonne. Comments from report The requirements for bunch-to-bunch accuracy of the polarization measurement are.

Energy deposit in photon detector for different shieldings

Need to evaluate effect on detector performances

Page 29: Compton polarimeter for EIC Alexandre Camsonne. Comments from report The requirements for bunch-to-bunch accuracy of the polarization measurement are.

Detector technologies

• Radiation hard ( 3 mA current ! )– Diamond– Silicon ( regular/ high radiation / cryo cooled )

• Radiation hard and fast– Superconducting detector NbN NbTi ( Early Career )– Quartz detector

• All in vacuum• Roman pot option

Page 30: Compton polarimeter for EIC Alexandre Camsonne. Comments from report The requirements for bunch-to-bunch accuracy of the polarization measurement are.

Quartz Integrating Detector

Page 31: Compton polarimeter for EIC Alexandre Camsonne. Comments from report The requirements for bunch-to-bunch accuracy of the polarization measurement are.

Tracking-Integrating Hybrid System

Quartz detector lacks segmentation, so no “built-in” knowledge of the analyzing power from fitting spectrum Will investigate using microstrip detector in tandem with chunk of quartz Periodic measurements at lower luminosity will allow use of strip detector to

constrain analyzing power

Page 32: Compton polarimeter for EIC Alexandre Camsonne. Comments from report The requirements for bunch-to-bunch accuracy of the polarization measurement are.

Compton photon vs electron• Past experience

– HERA photon only longitdudinal and transverse (1.4 % )– SLAC : SLD electron detection 50 GeV best Compton measurement ever

made 0.5 %

• For Compton electron– Larger displacement the better for improved resolution and signal to

background ratio– Opposite requirement to photon detection where minimum is sought to

reduce• Need to evaluate optimum case : photon only, photon and

electron detection, electron detection only• 2 Ips : one optimized for photon and one for electron

Page 33: Compton polarimeter for EIC Alexandre Camsonne. Comments from report The requirements for bunch-to-bunch accuracy of the polarization measurement are.

GEMC• EIC standard setup• Easy to add

additionnal detectors

• Need to start looking at background

• Shielding and collimation optimization

Page 34: Compton polarimeter for EIC Alexandre Camsonne. Comments from report The requirements for bunch-to-bunch accuracy of the polarization measurement are.

Single Superconducting Nanowire Photon Detectors (SNSPD)

•Thin superconducting stripe of 5 to 10 nm thickness

•Meander geometry to maximize surface, typical width of strip 10 nm and length about 100 nm

•Signal speed depends on material, substrate and geometry

•Mostly developed for astrophysics with IR sensitivity : Nasa Jet Propulsion Laboratory, Lincoln Laboratory ….

Page 35: Compton polarimeter for EIC Alexandre Camsonne. Comments from report The requirements for bunch-to-bunch accuracy of the polarization measurement are.

Single Superconducting Nanowire Photon Detectors (SNSPD)

• Review : Chandra M Natarajan et al 2012 Supercond. Sci. Technol. 25 063001 doi:10.1088/0953-2048/25/6/063001

Page 36: Compton polarimeter for EIC Alexandre Camsonne. Comments from report The requirements for bunch-to-bunch accuracy of the polarization measurement are.

Superconducting electronics• Detector are fast, need fast electronics to take advantage

• Detector will be in Helium bath, integrated superconducting electronics can reduce

• Need to redevelop standard electronics tools– Amplifier– Discriminator– Logic– Analog to Digital Converter– Time to Digital Converter

Page 37: Compton polarimeter for EIC Alexandre Camsonne. Comments from report The requirements for bunch-to-bunch accuracy of the polarization measurement are.

Superconducting strip detector

• Superconducting NbN Microstrip Detectors (1999 ) RD 39 Collaboration R. Wedenig and T.O. Niinikoski CERN et al

• Could see charged alpha•But could not detect minimum ionizing particle at that time because of electronics sensitivity

Page 38: Compton polarimeter for EIC Alexandre Camsonne. Comments from report The requirements for bunch-to-bunch accuracy of the polarization measurement are.

Discriminator• Characterization of

superconducting pulse discriminators based on parallel NbN nanostriplines

M Ejrnaes et al 2011 Supercond. Sci. Technol. 24 035018 doi:10.1088/0953-2048/24/3/035018

Page 39: Compton polarimeter for EIC Alexandre Camsonne. Comments from report The requirements for bunch-to-bunch accuracy of the polarization measurement are.

Conclusion

• Photon doable but difficult, need more studies• Electron looks reasonable

– Halo contribution would be useful– Simulation in GEMC for background studies– Option to give up on photon and optimize only for

electron