Throughout this manual, signal words are present to advise of safety precautions and/or standard practices. Obey these signal words as defined below: DANGER! - indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. WARNING! - indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. CAUTION! - indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. Notice: - used to address practices not related to personal injury. This manual is property of the owner, and should be left with the unit when start-up is complete. Aircel LLC. reserves the right to change design and specifications without prior notice. Installation, Operation, and Service Information Aircel AHLD E-Series Heatless Regenerative Desiccant Air Dryer Models AHLD-70 E, 100 E, 150 E, 200 E, 250 E, 300 E, 350 E, 450 E, 500 E, 600 E, 750 E Installation and Operation Manual

Transcript of Compressed Air Dryer Technology - Installation and Operation … · 2017-11-15 · Aircel LLC....

Page 1: Compressed Air Dryer Technology - Installation and Operation … · 2017-11-15 · Aircel LLC. reserves the right to change design and specifications without prior notice. Installation,

Throughout this manual, signal words are present to advise of safety precautions and/or standard practices.

Obey these signal words as defined below:

DANGER! - indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.

WARNING! - indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.

CAUTION! - indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury.

Notice: - used to address practices not related to personal injury.

This manual is property of the owner, and should be left with the unit when start-up is complete. Aircel LLC. reserves the right to change design and specifications without prior notice.

Installation, Operation, and Service Information

Aircel AHLD E-Series Heatless Regenerative Desiccant Air DryerModels AHLD-70 E, 100 E, 150 E, 200 E, 250 E, 300 E, 350 E, 450 E, 500 E, 600 E, 750 E

Installationand Operation Manual

Page 2: Compressed Air Dryer Technology - Installation and Operation … · 2017-11-15 · Aircel LLC. reserves the right to change design and specifications without prior notice. Installation,

2

WARNING!

General Safety Procedures

• Improperinstallation,operation,ormaintenancemaycontributetoconditionsintheworkareaorfacilitythatcouldresultinpersonalinjuryandproductorpropertydamage.Checkthat all equipment is properly selected and sized for the intended use.

• Consultandcomplywithnationalandlocalcodesrelatingtofireorexplosionandallother appropriate codes when determining the location and operation of this equipment.

• Safeandefficientoperationoftheunitdependsonproperinstallation.

• Authoritieswithjurisdictionshouldbeconsultedbeforeinstallingtoverifylocalcodesandinstallationprocedures.Intheabsenceofsuchcodes,installunitaccordingtotheNationalElectricCode,NFPANo.70-latestedition.

• Aqualifiedinstallationandserviceagentmustcompleteinstallationandserviceofthisequipment.

• DONOTweldon/topressurevesselormodifyitinanyway.

• DONOTremove,modify,oradjustprotectiveorsafetydevices.

• Lockoutpowersupplyanddepressurizesystembeforeperformingmaintenanceorservicework.

• DONOToperatetheequipmentwiththecontrolpaneldooropen.

Notice: Foroptimumperformance,useonlyAircelreplacementparts.

Thismanualcontainsspecificprecautionarystatementsrelativetoworkersafety. Readthoroughlyandcomplyasdirected.Discusstheuseandapplicationofthis equipmentwitharepresentative.Instructallpersonnelonsafeuseandmaintenance

procedures. Understand and obey the following signal words used in this manual.

•DANGER! - indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.

•WARNING! - indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.

•CAUTION! - indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury.

•Notice: - used to address practices not related to personal injury.

Notice: Foroptimumperformance,useonlyoriginalequipmentreplacementparts.

Notice:Forinformationandnotesspecifictoacustomdesignedandbuiltdryer,referencethe drawingpackageprovidedwiththeunit.Seewarrantyonmanualbackcoverfor custom engineered products.

AircelAHLDE-Series-Models70-750

Page 3: Compressed Air Dryer Technology - Installation and Operation … · 2017-11-15 · Aircel LLC. reserves the right to change design and specifications without prior notice. Installation,

HeatlessRegenerativeDesiccantAirDryer

3

Introduction

ThankyouforpurchasingAircel’sAHLD-ESeriesHeatlessRegenerativeDesiccantAirDryerwithIntegratedEnergyManagementPurgeReductionSystem.Youarenowtheproudownerofoneofthefinestdesiccantdryersinthemarket.AircelAHLD-Eseriesdryersareengineeredandmanufacturedtoprovideyou with many years of trouble free service and provides energy efficient operation by reducing the overall dry purge air required for regeneration saving energy and money. To ensure that you get the get first class servicefromthisequipment,werecommendyoutakesometimeandreadthecontentsofthismanual. Thismanualcontainsalltheinformationrequiredforinstallingandmaintainingyournewequipment.Italso includes the safety procedures and corresponding drawings. We strongly suggest that all personnel involved with the machine, read the entire contents of the manual before proceeding with the installation or maintenance activities. Themanufacturerreservestherighttomakechangeswithoutanypriornotificationandisnotobligatedinanymanner.InformationinthismanualisdeemedcurrentatthetimeofpublicationandAirceldisclaimsallliability for any errors resulting in any loss or damage. IfyouhavequestionsorneedadditionalcopiesorwouldliketoscheduleaAircel'sservicemanvisit,contactyour distributor.

Aircel 323 Crisp Circle

Maryville,TN37801Toll-Free:(800)767-4599

Tel:(865)681-7066Fax:(865)681-7069

Sales Information:[email protected]

Order Entry:[email protected]

www.AircelDryers.com

Contents

SafetyStatements .................................................. 2Introduction .......................................................... 3DataSheet ............................................................. 4SafetySymbols ...................................................... 5GeneralSafetyInstructions ................................... 6Description............................................................ 7 Purpose&IntendedUse .............................. 7 Features&Options ..................................... 8InspectiononArrival ............................................ 9TechnicalSpecifications ...................................... 10HowitWorksDiagram ...................................... 11Installation .......................................................... 12TypicalInstallation ............................................. 12InstallationChecklist .......................................... 13Start-UpProcedure .............................................. 14Shut-DownProcedure ......................................... 15

SequenceofOperation ........................................ 15ServiceInformation ............................................. 17 Maintenance&Checklists ......................... 17Troubleshooting .................................................. 19Troubleshooting Table ........................................ 20DesiccantMaterialSafetyDataSheet .................. 22 AircelProgrammableController ......................... 27ElectricalDrawings ............................................. 36 MainPower&PLCInput.......................... 36 PLCOutput&Sensors .............................. 38 BackPanel .................................................. 40 Enclosure Layout ....................................... 41ServiceNotes ...................................................... 42Warranty............................................................. 44

Page 4: Compressed Air Dryer Technology - Installation and Operation … · 2017-11-15 · Aircel LLC. reserves the right to change design and specifications without prior notice. Installation,

4

Data Sheet

ModelNumber _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ SerialNumber _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

DryerType _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ DateofManufacture _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

ShipDate _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ InstallationDate _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

CustomerName _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ Address _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

AddressCont’d _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Accessories _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Other _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

DryerInletAirFlowRate _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

DryerInletTemperature _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

DryerAmbientTemperature _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

DryerVoltage _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

DryerMCAMinimumCircuitAmpacity _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

DryerMOPMaximumOvercurrentProtection _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

DryerOperatingPressure _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

DryerMaximumOperatingPressure _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

DryerVesselPressureReliefValveSetting _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

DryerDesiccantType _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

DryerDesiccantWeightperVessel _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

DryerDesiccantWeightTotalforSystem _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

DryerOutletDewpoint _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

DryerControlTimeCycle _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

DryerEMSRHSensorSetting(forsensingmid-bedmoisture) _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

HighDewpointSetting(option) _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

DemandCycleSetting(option) _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

OutletDewpointReadoutonDisplay(option) _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

ElectricalDrawingNo. _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

MechanicalDrawingNo. _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

PLCSoftwareProgramNo. _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

ControlAirFilterElementNo. _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

InletPre-FilterElementNo.(option) _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

OutletAfter-FilterElementNo.(option) _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

InletValve _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

PurgeExhaustValve _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

VesselNationalBoardNo.(leftandrightvessels) _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

DryerSystemWeight _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

AircelAHLDE-Series-Models70-750

Page 5: Compressed Air Dryer Technology - Installation and Operation … · 2017-11-15 · Aircel LLC. reserves the right to change design and specifications without prior notice. Installation,

HeatlessRegenerativeDesiccantAirDryer

5

Safety Symbols Used in Manual

Important Information:Readersofthemanualmustpayextraattentiontoinstructions and information succeeding this symbol.

Warning: This indicates that it is dangerous and could result in physical injury and death if the instructions are not followed correctly.

Electrical Danger High Voltage:Thismeansthatthereisariskofelectricshockandonly authorized personnel with proper gear must approach it.

High Noise Area: All personnel are required to wear ear protectors before approaching the vicinity of the equipment.

Hazardous Fumes & Gases: Personnelmustwearprotectivegeartopreventinhalingof the gases and fumes.

Suspension Points:Lookforthesesymbolsbeforemakinganyattempttomoveorrelocate your equipment.

Tips & Suggestions:Followingthesetipscanmakeyourworkeasier.

Extreme Caution: Thisindicatesthattheremightbepossibleriskofmaterialdamageandpersonnelareadvisedtoexerciseextracaution.

Safety Instructions

Page 6: Compressed Air Dryer Technology - Installation and Operation … · 2017-11-15 · Aircel LLC. reserves the right to change design and specifications without prior notice. Installation,

6

General Safety Instructions

What You Must Do

1. Certified/authorizedelectriciansmustperformelectricalwork2. ElectricalworkmustconformtothespecificationsindicatedbyAircelandanylocalorstatelawsthat

may apply. 3. Personnelmustwearappropriatesafetygearbeforeworkingonanyelectricalormechanicalaspectsof

the machine. 4. Appropriatetoolshavetobeusedforallinstallationandmaintenancework.Ifspecialtoolsarerequired

and are not available to the installation crew, contact the factory or your Aircel representative. 5. AcopyoftheOperationManualmustbemadeavailabletoallpersonnelinvolvedwiththeinstallation,

operation and maintenance of the equipment. 6. Before performing any maintenance operations on the equipment, the unit must be shut down, isolated,

electrical power removed, and completely depressurized. 7. To ensure compatibility and continued trouble free operation, only genuine Aircel parts must be used.

What You Must Not Do

1. Donotmakeconstructionalchangestotheunit.OnlyAirceloritsauthorizedrepresentativeswiththepriorapprovalcanperformanyconstructionalworkonthemachine.

2. Donotuseforeignparts.3. Compressedairfromthedryersisnottobeusedforbreathingpurposes–installabreathingairpackage

toensureconformancewithOSHAregulations4. Donotdisableordisengageanyprotectiveequipmentusedonthemachine.

Safe Operating Procedures

1. PressurizeanddepressurizecompressedairSLOWLY!Alwaysopenairvalvesslowlywhenpressurizingthe airline system or equipment. Replace air slowly when depressurizing your air system or equipment.

2. Circuitbreakers,fusibledisconnect,andwiringshouldconformtonationaland/orlocalelectricalcodes.Makecertainthatqualifiedelectricalpersonnelperformtheelectricalinstallationforthisunit.

3. Only use original fuses for the rated voltage and current. 4. Shutdowntheunitinthecorrectrecommendedprocedure.5. BeforeanyworkonsystemalwaysDepressurizetheunitandremoveallelectricalpower.6. Aftershutdown,putupwarningnoticetopreventtheunitfrombeingswitched“ON”accidentally.7. Inspectallpiping,hosesandconnections.Makesurethatallhosesareingoodconditionandarerated

forthecorrectworkingpressure.Donotallowhosestocomeintocontactwithoil,chemicals,orsharpobjects.

8. Securecondensatedrainlines.Unsecuredflexibledrainlinesmaywhipviolentlyunderpressureandmaycause bodily harm. Aircelairdryersdonotremovecarbonmonoxideandisnotsafeforhumanrespiration(breathing).BreathingairmustbeatleastgradeDqualityasdescribedincompressedairandgasassociation(CAGI)commodityspecifications67.1-1966.UsermayrefertoOSHA29CFI1910.134forspecialprecautionsand equipment suitable for breathing air applications. Aircel disclaims any liability what so ever for loss, injury or damage.

AircelAHLDE-Series-Models70-750

Page 7: Compressed Air Dryer Technology - Installation and Operation … · 2017-11-15 · Aircel LLC. reserves the right to change design and specifications without prior notice. Installation,

7

HeatlessRegenerativeDesiccantAirDryer

Why We Need Compressed Air Dryers Untreated compressed air contains many contaminants such as water, compressor oil, pipe scale and contaminationfromambientair.Allthesecontaminantscauseexcessivecorrosion,erosion,freezingandproduct contamination to all components that come in contact with the untreated compressed air. A regenerative type dryer system with all recommended filtration will remove these contaminants to harmless levels. The end result is that instruments that come in contact with the dry compressed air stay clean and do notcorrode,thereforelastingmuchlonger.Productsthatmaycomeincontactwithcleandrycompressedair are virtually unaffected. Therefore rejection rates are reduced.

Purpose & Intended Use AircelRegenerativeDesiccantAirDryerscandrycompressedairto-100°FPDP(PressureDewPoint),StandardRegenerativeDesiccantAirDryersdrycompressedairdownto-40°FPDP.Thecompressedairstream is passed through a desiccant bed, which removes the moisture through the process of adsorption. Twin towers filled with desiccant alternate between drying and regeneration either based on the Energy ManagementSystem(EMS)controlorafixedtimecycle.Aircelmanufacturesvarioustypesofdesiccantair/gas dryers. These dryers offer fail-safe design in the event of power interruption. Air will continue to flow throughthedryerwithoutdeadheading;alsopurgeexhaustvalveswillclosepreventinglossofairpressure.The tower operating status lights and the highest quality non-lubricated air/gas inlet valves will ensure reliable operation for many years to come.

Product Description

Page 8: Compressed Air Dryer Technology - Installation and Operation … · 2017-11-15 · Aircel LLC. reserves the right to change design and specifications without prior notice. Installation,

• IntegratedEnergyManagementPurgeReductionSystemforefficientenergysavingsandreducedcostofoperation.

• Optimaltowersizeforlowvelocitiesreducingdesiccantfluidization,andhighcontacttimeforefficientlow dewpoint performance.

• Towerpressurereliefvalves.• Standarddesigncapacitybasedon100psig,100°Finletair,100°FambientairandPDPof-40°F.• Purgeexhaustmufflersforquietoperation.• Towerpressuregaugesforadditionalvisualoperationofdryeroperation.• Stainlesssteeldesiccantsupportsandairdiffuserstopreventchanneling.• Counter-currentreactivationforefficientdesiccantregeneration.• PLCControlledElectricalSystem• Adjustable(5min.,10min.)Cycletimes:10minutecycleforthestandard-40°FPDPoutletdewpoint

systems,5minutecycleusedintheoptional-100°FPDPoutletdewpointsystems.• Controlledrepressurizationtoslowlyrepressurizetheregeneratedvesseltolinepressurepriortoswitch

over preventing desiccant bed movement and attrition.• Failsafedesign:failureofpowerand/orpilotaircausesthepurgeexhaustvalvestocloseeliminating

lossofairpressure.TheSystemalsoprovidesuninterrupteddryingairflowpreventingadeadheadingaffect.

• Controlpilotairfilterprovidescleanairtoaircontrolsystemforlongtrouble-freereliableoperation.• Desiccanttowersaredesigned,fabricatedandstampedaccordingtoASMEcode.(AHLD-70Eandup).• Desiccantfillanddrainportsforeaseofdesiccantreplacement.• Structuralsteelframe• Highlyreliablenon-lubricatedairinletandoutletvalves(APV)AutomaticPistonValve(AHLD-70E—

AHLD-750E)• Highlyreliableangleseatdesignpurgeexhaustvalves(AHLD-70E—AHLD-750E).• ToweroperatingL.E.D.statuslights(LeftTowerDrying,RightTowerDrying,LeftTower

Regenerating,RightTowerRegenerating)• ON/OFFswitchandpowerONlight.• NEMA4weatherresistantelectricalsystemconstruction.

8

Standard Features

Additional Options

• -100°Foutletpressuredewpoint• Failure-to-shiftalarm(withpressuretransducers)• Outletdewpointsensorwithdewpointreadoutonsystemdisplay• Highhumidityalarm• Outletdewpoint4-20masignal• Mounted,pipedandwiredfiltrationpackages

AircelAHLDE-Series-Models70-750

Page 9: Compressed Air Dryer Technology - Installation and Operation … · 2017-11-15 · Aircel LLC. reserves the right to change design and specifications without prior notice. Installation,

HeatlessRegenerativeDesiccantAirDryer

9

Inspection on Arrival

All Aircel dryers are tested and operated before shipment. However, shipping stresses have the potential to cause damage to the unit. To ensure smooth installation, it is recommended that immediately upon receipt of the unit, the system is checkedforthefollowing:

1. Makesureyouhavereceivedallthecrates/packagesthatareindicatedinthepackingslip.

2. Removethecrateandpackaging.Inspecttheunit for any visible damage.

3. Report any damage to the delivery carrier.

4. RequestawritteninspectionreportfromtheClaimsInspectortosubstantiatetheclaim.

5. Fileclaimswiththedeliverycarrier.

6. Compareunitreceivedwithdescriptionofproductordered.ChecktheserialplatelabelandmakesurethatitisthecorrectModelwasordered.NotetheequipmentCapacityandPowerSupplyrequirementsandensurethattheyare in accordance with your specifications. The rated conditions of the dryer are indicated on theserialplatelabel.Ifthereisanydiscrepancy,contact your representative listed on the manual backcover.

7. Shippingstressescanloosenconnections.All pipe and tubing connections should be inspected.

8. Reportincompleteshipmentstothedelivery carrier and your Aircel service representative.

CAUTION!

• Donotmisuseormodifyunderanyconditions.Misuseormodificationof this equipment may result in personal injury.

Page 10: Compressed Air Dryer Technology - Installation and Operation … · 2017-11-15 · Aircel LLC. reserves the right to change design and specifications without prior notice. Installation,

10

Technical Specifications

How Does it Work? (seediagram1)

Moisturesaturatedcompressedairentersthecoalescingprefilter(F1)whereaerosolsarecoalesced then drained via an automatic drain system. The moist water vapor-laden inlet air free of liquid water flows to the inlet of the dryer throughtheAPV(AutomaticPistonValve)(V1)which diverts the inlet air to one of the towers, in thisexampletower(T1).Airflowsupwardthroughthe adsorbent bed removing the moisture vapor, thedriedairflowexitsthetowerthroughtheoutletAPVvalve(V2)flowingtotheoutletparticulateafterfilter(F2)whichremovesparticulatesfromthe air stream. Clean and dry air now flows to the process air distribution system.

As one tower is drying air, the other tower will be regenerating(purging)theadsorbentbed.Inthisexample,tower(T2)willberegenerating.Priortoregeneration,theexhaustvalve(V4)isopenedand the tower is depressurized to near atmospheric pressure, the tower will now be regenerating. Duringtheregeneratingprocessasmallportionofdryoutletcompressedairisused,15%onaveragebasedonstandarddesigncapacityof100psig,100°Finletair,100°FambientairandPDPof-40°F.ThedryregenerationairflowischanneledthroughtheoutletAPVvalvetotheregeneratingtower(T2)removingmoisturefromtheadsorbentbedandexitstheregeneratingtower(T2)throughexhaustvalve(V4)andexhaustmufflertoambient.Afterregenerationcycleiscomplete,valve(V4)closescausingtower(T2)torepressurizetolinepressure.

Next,thetowerswillswitchwhenexhaustvalve(V3)openscausingtower(T1)todepressurizeandregenerate,simultaneouslytheinletandoutletAPVvalves(V1)and(V2)willshiftthepistonstothelowpressuretower(T1)causingtheinletairflowtobedivertedtotower(T2)whichwillnowbethedrying tower. This switching process will continue repeatedly.

The dryer control system is completely automatic and cycles the system through the drying and regeneration cycles. The standard cycle drying time is5minutes,regenerationcycleis4minutes,andrepressurizingcycleis1minute.

TheAircelAHLDE-SeriesHeatlessDryerincorporates a unique energy saving control system to reduce purge air loss with its integrated Energy ManagementPurgeReductionSystemwhichutilizesa moisture sensor sampling the air from mid bed of theon-streamdryingtower,afterthefixedpurgetime is complete the regenerating/purging tower will repressurize.Ifthemoisturesensorsensesalowmoisture condition or low load in the drying tower, the drying tower will remain in the drying mode afterthefixeddryingtimecycleforanextendedperiod of time. The end result is an overall purge reduction and significant energy savings.

CAUTION!

• Donotmisuseormodifyunderanyconditions.Misuseormodificationof this equipment may result in personal injury.

AircelAHLDE-Series-Models70-750

Page 11: Compressed Air Dryer Technology - Installation and Operation … · 2017-11-15 · Aircel LLC. reserves the right to change design and specifications without prior notice. Installation,

11

HeatlessRegenerativeDesiccantAirDryer

Diagram1:HowitWorks

Drying Tower

Regenerating Tower

Air Saturated with Moisture

Dry Air

F1F2

T2T1

V1

V2

F1 - Mounted Pre-FilterF2 - Mounted After-FilterV1 - Automatic Piston ValveV2 - Automatic Piston ValveV3 - Purge Exhaust ValveV4 - Purge Exhaust ValveT1 - Desiccant Tower 1 T2 - Desiccant Tower 2

V4V3

Regeneration Air

Page 12: Compressed Air Dryer Technology - Installation and Operation … · 2017-11-15 · Aircel LLC. reserves the right to change design and specifications without prior notice. Installation,

12

Installation

Pre-requisites for Installation

To ensure a safe and smooth installation, we recommend you go through the steps indicated below:

• MakesurethatallpersonnelinvolvedhavereadthisOperationManualthoroughly.Ifyouhaveany questions, feel free to contact your Aircel representative or the factory and we will be glad toassistyou.Ifyouneedhelpwiththecommissioning,wewillbegladtoscheduleafactoryserviceman to visit your site and commission the dryer for a nominal fee.

• HaveextracopiesoftheOperationManuals.• Specialcaremustbetakenwhiletransportingtheunittotheinstallationsite.• Dryermustnotbemovedorliftedbytheattachedpiping.

Location

• Carefulconsiderationshouldbegiventothelocationofthedryerinordertoassureoptimumresults. Ensure that the load bearing weight of the floor is adequate for the weight of the dryer.

• Thedryershouldbelocatedinanopenareaandalevelground.Dryershouldbeboltedtothefloorto eliminate vibrations.

• Theambienttemperatureshouldbebetween40°Fand100°F.Lowtemperaturecouldaffectthedryer process and result in high outlet dew point.

• Inconditionswheretheambientdropsbelowfreezing,Aircelrecommendstheuseofheattraceonany coalescing filter sumps and drain lines and the use of heated type drains.

• Dryerandaccompanyingfiltersshouldbeinstalledwithatleast2-5feetclearancefromtheadjoining walls to provide easy access for routine maintenance.

TypicalInstallation

AircelAHLDE-Series-Models70-750

Page 13: Compressed Air Dryer Technology - Installation and Operation … · 2017-11-15 · Aircel LLC. reserves the right to change design and specifications without prior notice. Installation,

13

HeatlessRegenerativeDesiccantAirDryer

Onlyqualifiedpersonnelshouldmakeelectricalandmechanicalconnections.

Equipment for Installation: This dryer does not need any special tools for installation

Foundation:Dryershouldbemountedonasuitablystructuredflatandlevelfloororbasethatisfreefromvibration.Specialcaremustbeusedwhenliftingthedryertopreventtip-over

Mounting: Bolt dryer to the foundation using the boltholes provided in the frame.

Piping:Connecttheinletofthedryertothemoistgasfromthecompressor/receiver/inletfilter.InstalltheInletpipingandtheinletshutoffvalve,InstalltheOutletpipingandtheoutletshutoffvalve(aunionwith a valve by-pass can be installed at the inlet and outlet valves to accommodate isolation of the dryer formaintenance).Compressedairpipinghastobeatleastthesamesizeasthatoftheinletandoutletconnections of the dryer. Larger pipe sizes can be used with reducers.

Back Pressure Regulator:Installbackpressureregulatortopreventanypossibilityoffluidizationofthedesiccant bed. When there is a sudden increase in the demand for compressed air downstream of the dryer, a huge pressure drop develops and can affect the performance of the dryer and the drying material (desiccant).

Desiccant:Makesurethatthedryertowersarefilledwithdesiccant.Largerdryersmayhavedesiccantshipped separately – in which case, the media has to be filled into the pressure vessels from the desiccant fillports.Caremustbetakenwhenfillingthemediaanditmustbedonegraduallytopreventpowdering.

Muffler:Iftheeventthatmufflershavebeenshippedloose,theymustbeinstalledandsecured

By-pass:Ifthedryerisnotsuppliedwithoptionalby-passvalveitishighlyrecommendedthatby-passvalve be installed around the dryer and filters. These by-pass shut-off valves will permit the dryer and filters to be removed from the compressed air system for servicing without shutting down the entire compressed air system.

Electrical:Makeallelectricalconnectionstothedryerasshownonthewiringdiagram.Specialcaremustbetakeninconnectingthepropervoltageasindicatedonthespecificationsheetandwiringschematic.

Additional Valving/Piping:Wheninstallingequipmentorcomponentskeepinmindtheserviceabilityofthe equipment and provide additional valves to isolate, bypass, and to depressurize as needed.

Exhaust:Ifyouintendtoventyourexhaustwithadditionalpiping,thedischargepipingfromtheexhaustshouldnotbepipedupwardwithoutanarrangementforremovingtrappedcondensate.Makesurethatyoudonotapplyabackpressureonthisexhaustsystem.Ifexhaustpipingistobeextended,trytostaywithin15to20feetandusethenextlargerpipesize.

Note: Itismandatorythatdryerbegrounded.Useofyourplantsframeasagroundmaycauseproblemswith the control. A fused disconnect is not supplied with this equipment therefore one must be supplied bycustomer.Allelectricalfuses,breakers,etc.shouldbeproperlysized.

Aircel is not liable for any code violations; component damage, downtime or consequential damage related to customer supplied electrical components and connections.

Installation

Page 14: Compressed Air Dryer Technology - Installation and Operation … · 2017-11-15 · Aircel LLC. reserves the right to change design and specifications without prior notice. Installation,

14

Start-Up Procedure

At any point during the process of startup or shutdown, you notice anything unusual; we recommend you refertotheoperationmanualimmediately.Ifyoucannotfindtheanswerinthetroubleshootingsection,contact your Aircel representative or the factory at once.

1. Ensurethatthedryerisconnectedtoasuitablecompressedairsupply.Makesurethat the pressure of the supply is equal to the normal operating pressure of the dryer.

2. Checktomakesurethe“shut-off’valvesare closed and that by-pass valve is open.

3. Close all manual drain/vent valves. 4. Slowlypressurizethedryerbygradually

(slowly)openingtheinletshut-offvalvetotheOPENposition.

5. Whenbothtowersofthedryerarecompletelypressurized,checkthecompletesystemforpossibleairleaks.Usesoapand water to test all joints and fittings. Ifanyleaksaredetected,immediatelydepressurizetheunitandcorrecttheleaks.

6. Makecertainthatanyautomaticcondensate drain isolation valves are in the open position so proper condensate draining can occur.

7. Whennormaloperatingpressureisreached,switchonelectricalpower(TurnswitchtoONposition)

8. Withby-passvalveclosed,opentheoutletvalve slowly to allow air downstream.

9. Whenenergizedoneofthetowersshoulddepressurize.

10.Checktheoperationofseveralcyclescompletely by following the control panel display screen operation, the panel lights ontheelectricalbox,andthetowerpressuregaugestomakecertainthedryersystem is operating as displayed. Also refertothehowitworkssection,flowdiagram, electrical drawing, dryer control display screen descriptions, and sequence of operation in this manual for reference.

11.Checkthedrainvalveforproperoperationanddischargeofliquid(filtersandseparators,etc.).

12.Nearthedryeroutlet(APV)valve,checkthe control air/ pilot air regulator secondary pressure, the regulator gauge should read 100psig.Increaseordecreaseregulatorknobtoachievea100psigcontrolairsecondary pressure reading.

13.Makecertainthepurgeexhaustvalvesslowlyopenwithinan8to12secondtimeperiod, some adjustment of the flow control valve attached to the actuator may be required, after adjustment tighten down the lockingcollar.

14.MakecertainaslightamountofairflowisfeltattheendoftheEMSRHsensorsamplecellexhaustcoiltube(thisisnormallylocatedatthebackofthedryer)adjust the needle valve to give more or less flow.

15.Reviewthedryersystemdisplayscreenshots(inthismanual)tomakecertainthe parameters are set as needed in the customer dryer.

16.Purgeairflowispresetandnotadjustable.

After the initial startup, the dryer operation is completely automatic. To understand the details of the operation,werecommendyouusethehowitworkssection,flowdiagram,electricaldrawing,dryercontroldisplay screen descriptions, and sequence of operation in this manual for reference.

AircelAHLDE-Series-Models70-750

Page 15: Compressed Air Dryer Technology - Installation and Operation … · 2017-11-15 · Aircel LLC. reserves the right to change design and specifications without prior notice. Installation,

15

HeatlessRegenerativeDesiccantAirDryer

Shut-Down Procedure

At any point during the process of startup or shutdown, you notice anything unusual; we recommend you refertotheoperationmanualimmediately.Ifyoucannotfindtheanswerinthetroubleshootingsection,contact your Aircel representative or the factory at once.

1.SlowlyOPENtheby-passvalve.2.SlowlyCLOSEtheInletandoutlet“shut-off”valves.3.TodepressurizethedryeraftertheDryerisisolated.TurnPowerON…apurgeexhaustvalvewill open and the dryer system starts to depressurize, also the manual vent valve on the outlet afterfiltercanbeopenedtodepressurizetheDryeruntilthetowerpressuregaugesread‘0’psig.4.Switchoffelectricalpowerafterbothtowershavebeendepressurized.

Sequence of Operation

Step 1: Vessel 2 Depressurizing (0-5 secs) Vessel2(T2)purgeexhaustpilotsolenoidvalveisenergizedwhich suppliescontrolairtothepurgeexhaustvalve(V4)whichopens slowly,depressurizingvessel2(T2).Simultaneouslytheinlet andoutletAPV(AutomaticPistonValveV1&V2)shiftpositions directingtheinletairtovessel1(T1)tobedryingtheair.Theair flowsupthroughthedesiccantbedandexitstotheoutletAPV valve(V2)totheoutletparticulatefilterthentothecustomerdry process air system. Step 2: Vessel 2 Regenerating (6-240 secs) Step2isacontinuationofstep1exceptvessel2(T2)willbe regenerating,vessel2(T2)purgeexhaustvalve(V4)isstillopen, vessel1(T1)isdryingtheinletair.Asmallportionofdryoutletair fromvessel1(T1)(15%averagebasedonstandarddesigncapacity of100psig,100°Finletair,100°FambientairandPDPof-40°F) istakenthroughasmallorificeintheoutletAPVvalve(V2)and usedtoregeneratethedesiccantbedinvessel2(T2) until240secondshasbeenreached. Step 3: Vessel 2 Repressurizing (241-300 secs) Vessel2(T2)purgeexhaustpilotsolenoidvalvewillde-energize causingvessel2(T2)purgeexhaustvalve(V4)toclose,thisallows vessel2(T2)torepressurizetolinepressure,sinceaircontinues flowingthoughthesmallorificeintheoutletAPVvalve(V2) pressurizingvessel2(T2).

Page 16: Compressed Air Dryer Technology - Installation and Operation … · 2017-11-15 · Aircel LLC. reserves the right to change design and specifications without prior notice. Installation,

16

Step 4: Extended Drying Vessel 1 AfewsecondsbeforetheendofrepressurizationtheAHLD E-SERIESController’sintegratedEnergyManagementPurge ReductionSystemlooksatthemoisturesensor,ifthemoisture loadislowenough,vessel1(T1)willcontinuetodryforan extendeddryingperioduntilthemoistureloadhasreacheda sethighlevel,thecontrollerwillthenadvancetostep5and the vessels will switch. This feature reduces the overall purge consumption saving energy and money. Step 5: Vessel 1 Depressurizing (0-5 secs) Vessel1(T1)purgeexhaustpilotsolenoidvalveisenergizedwhich suppliescontrolairtothepurgeexhaustvalve(V3)whichopens slowly,depressurizingvessel1(T1).Simultaneouslytheinletand outletAPV(AutomaticPistonValveV1&V2)shiftpositionsdirecting theinletairtovessel2(T2)tobedryingtheair.Theairflowsup throughthedesiccantbedandexitstotheoutletAPVvalve(V2)to the outlet particulate filter then to the customer dry process air system.

Step 6: Vessel 1 Regenerating (6-240 secs) Step6isacontinuationofstep5exceptvessel1(T1)willbe regenerating,vessel1(T1)purgeexhaustvalve(V3)isstillopen, vessel2(T2)isdryingtheinletair.Asmallportionofdryoutletair fromvessel2(15%averagebasedonstandarddesigncapacity of100psig,100°Finletair,100°FambientairandPDPof-40°F) istakenthroughasmallorificeintheoutletAPVvalve(V2)and usedtoregeneratethedesiccantbedinvessel1(T1) until240secondshasbeenreached.

Step 7: Vessel 1 Repressurizing (241-300 secs) Vessel1(T1)purgeexhaustpilotsolenoidvalvewillde-energize causingvessel1purgeexhaustvalve(V3)toclose,thisallows vessel1(T1)torepressurizetolinepressure,sinceaircontinues flowingthoughthesmallorificeintheoutletAPVvalve(V2) pressurizingvessel1(T1).

Step 8: Extended Drying Vessel 2 AfewsecondsbeforetheendofrepressurizationtheAHLD E-SERIESController’sintegratedEnergyManagementPurge ReductionSystemlooksatthemoisturesensor,ifthemoisture loadislowenough,vessel2(T2)willcontinuetodryforan extendeddryingperioduntilthemoistureloadhasreacheda sethighlevel,thecontrollerwillthenadvancetostep1and the vessels will switch. This feature reduces the overall purge consumption saving energy and money.

Sequence of Operation (cont’d)

AircelAHLDE-Series-Models70-750

Page 17: Compressed Air Dryer Technology - Installation and Operation … · 2017-11-15 · Aircel LLC. reserves the right to change design and specifications without prior notice. Installation,

17

HeatlessRegenerativeDesiccantAirDryer

Maintenance

Priortoperforminganymaintenanceonthedryer,allpersonnelarestronglyadvisedtofamiliarizethemselves with the equipment by reading the entire contents of this operation manual. Aircel strongly recommends the strict adherence of all the safety procedures prior to any performing any maintenance activity on the dryer.

A. Thepressuredifferentialindicatorreferredtoasthe“Delta-P”isaverygoodindicatorofthestateofthefilterelements.MaintenancepersonnelmustpayattentiontothesetokeepthedryerrunningwithfullefficiencyChangefilterelementsonaregularbasis,onceayearmaximumfora1-shiftoperation.Changemorefrequentlyifoperating2or3shiftssuchasevery6months.

B. Theusefullifeofafilterelementdependsonthequalityofair.Freeopenareasforinputandexhaustwillensurelesserintakeofdirtandparticles.

C. Powdereddesiccantcanaccumulateinthemufflerandincreasethebackpressureintheregeneratingtower change mufflers on a regular basis typically every 2-3 months for optimum performance.

D. Oilandoilvaporcandrasticallyreducethelifeofthedesiccant.Takeprecautionstoeliminatealltraces of oil from the airflow

E. Fluctuatingdewpointindicatesunevendryingandregenerationbetweenthetowers,anexhaustvalvemaynotbeworkingproperlyormufflermaybecloggedordirty,alsovesseldiffuserscreenmay be clogged.

Weekly Checklist

1. Checkalldrainvalves,prefilter,afterfilterandseparators2. Checkanypressuredifferentialindicators(Delta-P)onthepre-filterandafterfilter(filterelements

shouldstillbechangedonregularbasisonceayearmaximumfora1shiftoperation.Changemorefrequentlyifoperating2or3shiftssuchasevery6months.).

3. Checkdryerforcorrectoperation.4. Verifydryerispurgingatthepurgeexhaust,afterdryerdepressurizes.5. Checkthedewpoint(ifavailable)toensurethedewpointisbeingachieved.6. Checkbackpressureinregeneratingtower,ifmorethanafewpsigonthepressuregauge,clean

orreplaceexhaustmufflers(Changemufflersonaregularbasistypicallyevery2-3monthsforoptimumperformance).

Page 18: Compressed Air Dryer Technology - Installation and Operation … · 2017-11-15 · Aircel LLC. reserves the right to change design and specifications without prior notice. Installation,

Semi-Annual Checklist

1. Removeandinspectallfiltersforexcessiveparticulateloadingandphysicaldamage–ifrequiredreplaceprefilters,afterfilters,pilotairfilterandmufflers(filterelementsshouldstillbechangedonregularbasisonceayearmaximumfora1shiftoperation.Changemorefrequentlyifoperating2or3shiftssuchasevery6months.).

2. Checkpressuredifferentialindicatorandifitturnsred,replacetheelement.3. Removeexhaustmufflers.Knockoutexcessparticulateandbackflowwithdrycompressedair.

Ifparticulatecannotberemovedcompletelychangetheexhaustmufflers.Checkbackpressureinregeneratingtower,ifmorethanafewpsigonthepressuregauge,cleanorreplaceexhaustmufflers.(Changemufflersonaregularbasistypicallyevery2-3monthsforoptimumperformance)

4. Checkdesiccantcondition.Powderinthemufflersisaindicationofthestatusofthedesiccant.5. Checkallsolenoidvalves-coilconditionandcontrolcircuit.6. Checkdryeroperation.7. InspectandcleaninletandoutletAPV(AutomaticPistonValves).

Annual Checklist

1. Replaceelementsinprefilters,afterfilters,andpilotairfilter.2. Replace mufflers. 3. Recalibratedewpointanalyzerprobe(ifused)sendbacktofactoryforrecalibration.4. ReplaceinletandoutletAPVvalveseals.5. Checkdryerforproperoperation.

18

Maintenance (cont’d)

WARNING!• Beforeanyserviceormaintenance

workisperformedontherefrigerated air dryer system, disconnectpowersupplyandlockout power supply and depressurize system.

• Followproperlockout/tagoutprocedures before performing serviceormaintenancework.

• Followallsafetyprocedurespriortoperforming any maintenance activity on the dryer.

AircelAHLDE-Series-Models70-750

Page 19: Compressed Air Dryer Technology - Installation and Operation … · 2017-11-15 · Aircel LLC. reserves the right to change design and specifications without prior notice. Installation,

19

HeatlessRegenerativeDesiccantAirDryer

The following section briefly discusses the various faults that can occur in the dryer, the reason of the faultandhowitcanberectified.Ifyoudonotfindthesolutiontoyourproblem,contactyourAircelrepresentative or the factory. All necessary safety and precautionary steps must be followed before attempting to perform any of the recommended measures to resolve any faults in the air dryer.

Beforeanyattemptismadetoundertakeanyaction,themachinemustbeshutdown,isolated,depressurized,andpowereddown.Followtheshutdownprocedures.

Note: Sometroubleshootingwillhavetobedonewhilesystemispressurizedandenergizedsouseextremecaution.

1. Depressurizetheunit2. Checktomakesureiftheunithasbeendamagedexternallyorifanypartismissing.3. Checkifthereisproperpowersupplyandifitcorrespondstothatmentionedonthedataplate.4. Checktoseeifthereispoweratalltheelectricalconnectionsinthemachineandthepropervoltage.5. Checkifcontrolairisavailableandtheproperpressureatallpneumaticallyoperatedcomponents.6. Makesureallshut-offvalvesareinthecorrectposition.7. Checktheairflow,inlettemperatureandpressureandmakesureitfallswithintheoperatingrange.

Troubleshooting

Page 20: Compressed Air Dryer Technology - Installation and Operation … · 2017-11-15 · Aircel LLC. reserves the right to change design and specifications without prior notice. Installation,

20

Troubleshooting (cont’d)

Problem Probable Cause Remedy

High Dewpoint High inlet air flow Reduce inlet air flow

Inletairtemperatureabovedesign spec

Reduce inlet air temperature to design spec

Poorpre-filtration Checkpre-filterelement,replaceifneeded

Inletairpressurebelowdesign spec

Increasepressuretothedryer

Desiccantcontaminated Replace desiccant

PurgefloworificeintheoutletAPVvalvemaybeclogged

DismantleoutletAPVvalve,andcleanouttheorifice

Backpressureinregenerating chambers

Mufflersareclogged,installnewmufflers

Exhaustvalve(s)notfullyopening or closing

Checkpilotvalveandpilotairsupply,dismantleandcleanexhaustvalve,checkflowcontrolvalveattachedtopurgeexhaustvalveactuatormaynotbeadjustedproperly(shouldbeadjustedsoexhaustvalveopenswithina8-12secondtimeperiod)

APVvalveleakingDismantleandclean,replacesealsandpistonifneeded

Noinputpower Checkthatdryerisonwithcorrectvoltage

Noinputpower Checkthatdryerisonwithcorrectvoltage

Controller failure Check,replaceifneeded

High-Pressure Drop Low inlet pressure Increaseinletpressuretodesignpressure

Desiccantdusting High inlet flow velocities due to high flow

Inletprefilterdirty Inspectandreplaceasneeded

High inlet flow rate Reduce inlet flow rate to meet dryer spec

Outlet filter dirty Inspectandreplaceasneeded

Desiccantdiffuserscreensclogged

Inspectedandcleanifneeded

High Back Pressure in Regenerating Tower

Purgemufflerclogged Clean and replace if needed

Desiccantdiffuserscreensclogged

Inspectedandcleanifneeded

Restrictivepurgeexhaustpiping

Clean and replace with larger pipe if required

AircelAHLDE-Series-Models70-750

Page 21: Compressed Air Dryer Technology - Installation and Operation … · 2017-11-15 · Aircel LLC. reserves the right to change design and specifications without prior notice. Installation,

HeatlessRegenerativeDesiccantAirDryer

21

Troubleshooting (cont’d)

Problem Probable Cause Remedy

Dryer Fails to Shift Towers

Exhaustvalves(s)notfunctioning

Checkpilotvalveandpilotairsupply,dismantleandcleanexhaustvalvecheckflowcontrolvalveattachedtopurgeexhaustvalveactuatormaynotbeadjustedproperly(shouldbeadjustedsoexhaustvalveopenswithina8-12secondtimeperiod)

Noinputpower Checkthatdryerisonwithcorrectvoltage.

Controller failure Check,replaceifneeded

Pilotairsupplyrestricted Checkpilotfilter,andpilottubingrestriction.

PurgefloworificeintheoutletAPVvalvemaybeclogged

DismantleoutletAPVvalve,andcleanouttheorifice

InletAPVvalvemalfunction Dismantle,clean,andreinstall

OutletAPVvalvemalfunction

Dismantle,clean,andreinstall

Purge Failure Purgemufflerclogged Remove and clean, replace if needed

PurgefloworificeintheoutletAPVvalvemaybeclogged

DismantleoutletAPVvalve,andcleanouttheorifice

Controller failure Check,replaceifneeded

Exhaustvalves(s)notfunctioning

Checkpilotvalveandpilotairsupply,dismantleandcleanexhaustvalvepurgeexhaustvalveactuatormaynotbeadjustedproperly(shouldbeadjustedsoexhaustvalveopenswithina8-12secondtimeperiod)checkcontrolsystem

Pressurization Failure

PurgefloworificeintheoutletAPVvalvemaybeclogged

Reduce inlet air flow

Exhaustvalves(s)notfunctioning

Checkpilotvalveandpilotairsupply,dismantleandcleanexhaustvalvepurgeexhaustvalveactuatormaynotbeadjustedproperly(shouldbeadjustedsoexhaustvalveopenswithina8-12secondtimeperiod)checkcontrolsystem

Page 22: Compressed Air Dryer Technology - Installation and Operation … · 2017-11-15 · Aircel LLC. reserves the right to change design and specifications without prior notice. Installation,

22

Desiccant Material Safety Data Sheet

2. Composition/information on ingredients

CAS Number Content (W/W) Chemical name 1333-84-2 >= 94.0 - <= 100.0 % Aluminum oxide (Al2O3), hydrate

3. Hazard identification

Emergency overview

CAUTION: MAY CAUSE EYE, SKIN AND RESPIRATORY TRACT IRRITATION. May cause difficulty breathing. Prolonged or repeated contact may result in dermatitis. Contact with the eyes or skin may cause mechanical irritation. Contains material which may indicate/cause the possibility of sensory and pulmonary irritation. Avoid contact with the skin, eyes and clothing. Avoid inhalation of dusts. Use with local exhaust ventilation. Wear a NIOSH-certified (or equivalent) particulate respirator. Wear safety glasses with side-shields. Wear chemical resistant protective gloves. Wear protective clothing. Eye wash fountains and safety showers must be easily accessible.

Potential health effects

Primary routes of exposure Routes of entry for solids and liquids include eye and skin contact, ingestion and inhalation. Routes of entry for gases include inhalation and eye contact. Skin contact may be a route of entry for liquified gases.

4. First-aid measures

If inhaled: Keep patient calm, remove to fresh air. If necessary, give oxygen. If not breathing, give artificial respiration. Seek medical attention if necessary.

Page: 1/5 (30286124/MDS_GEN_US/EN)

Company BASF CORPORATION 100 Campus Drive Florham Park, NJ 07932, USA

Safety data sheet F200 Revision date : 2009/12/04 Version: 3.0

1. Substance/preparation and company identification

24 Hour Emergency Response Information CHEMTREC: 1-800-424-9300 BASF HOTLINE: 1-800-832-HELP

AircelAHLDE-Series-Models70-750

Page 23: Compressed Air Dryer Technology - Installation and Operation … · 2017-11-15 · Aircel LLC. reserves the right to change design and specifications without prior notice. Installation,

23

HeatlessRegenerativeDesiccantAirDryer

Desiccant Material Safety Data Sheet

6. Accidental release measures

Cleanup: Vacuum up spilled product. Place into suitable container for disposal.

7. Handling and storage

Handling

General advice: Avoid dust formation in confined areas. Avoid contact with the skin, eyes and clothing. Ensure adequate ventilation.

Storage

General advice: Keep container tightly closed in a cool, well-ventilated place.

Storage stability: Keep container dry.

8. Exposure controls and personal protection

Components with workplace control parameters Aluminum oxide (Al2O3), OSHA PEL 5 mg/m3 Respirable fraction ; PEL 15 mg/m3 Total hydrate dust ;

ACGIH TWA value 1 mg/m3 Respirable fraction ;

Safety data sheet F200 Revision date : 2008/12/04 Version: 3.0

Page: 2/5 (30286124/MDS_GEN_US/EN)

If on skin: After contact with skin, wash immediately with plenty of water and soap. Consult a doctor if skin irritation persists.

If in eyes: In case of contact with the eyes, rinse immediately for at least 15 minutes with plenty of water. Immediate medical attention required.

If swallowed: No hazards anticipated. If large quantities are ingested, seek medical advice.

5. Fire-fighting measures

Flash point: Additional information: Use extinguishing measures to suit surroundings.

Hazards during fire-fighting:

No particular hazards known.

Non-flammable.

Protective equipment for fire-fighting: Wear self-contained breathing apparatus and chemical-protective clothing.

NFPA Hazard codes: Health : 0 Fire: 0 Reactivity: 1 Special:

Page 24: Compressed Air Dryer Technology - Installation and Operation … · 2017-11-15 · Aircel LLC. reserves the right to change design and specifications without prior notice. Installation,

24

Advice on system design: Provide local exhaust ventilation to control dust. Provide local exhaust ventilation to maintain recommended P.E.L.

Personal protective equipment

Respiratory protection: Wear a NIOSH-certified (or equivalent) particulate respirator. Observe OSHA regulations for respirator use (29 CFR 1910.134). Wear appropriate certified respirator when exposure limits may be exceeded.

Hand protection: Wear chemical resistant protective gloves., Consult with glove manufacturer for testing data.

Eye protection: Safety glasses with side-shields.

Body protection: Body protection must be chosen based on level of activity and exposure.

9. Physical and chemical properties

Safety data sheet F200 Revision date : 2008/12/04 Version: 3.0

Page: 3/5 (30286124/MDS_GEN_US/EN)

Form: Odour: Colour: pH value: Melting point: Boiling point: Vapour pressure: Density: Bulk density:

Partitioning coefficient n-octanol/water (log Pow): Viscosity, dynamic: Solubility in water:

10. Stability and reactivity

powder, granules, pellets, balls odourless off-white 9.4 - 10.1 2,050 °C

No data available. No data available. No data available.

approx. 650 kg/m3 38.0 - 52 lb/ft3 ( 68 °F)

No data available.

No data available. insoluble

Substances to avoid: water

Hazardous reactions: The product is chemically stable. Addition of water leads to increase in temperature.

11. Toxicological information

Oral:

Information on: Aluminum oxide LD50/rat: > 5,000 mg/kg (OECD Guideline 401)

----------------------------------

Desiccant Material Safety Data Sheet

AircelAHLDE-Series-Models70-750

Page 25: Compressed Air Dryer Technology - Installation and Operation … · 2017-11-15 · Aircel LLC. reserves the right to change design and specifications without prior notice. Installation,

25

HeatlessRegenerativeDesiccantAirDryer

Information on: Aluminum oxide Acute and prolonged toxicity to fish: DIN 38412 Part 15 static golden orfe/LC50 (96 h): > 500 mg/l The product has not been tested. The statement has been derived from products of a similar structure and composition. ----------------------------------

Information on: Aluminum oxide Acute toxicity to aquatic invertebrates: OECD Guideline 202, part 1 static Daphnia magna (48 h): > 100 mg/l ----------------------------------

13. Disposal considerations

Waste disposal of substance: Dispose of in accordance with local authority regulations. Check for possible recycling. Disposal requirements are dependent on the hazard classification and will vary by location and the type of disposal selected. All waste materials should be reviewed to determine the applicable hazards (testing may be necessary).

14. Transport information

Land transport USDOT

Not classified as a dangerous good under transport regulations

Sea transport IMDG

Not classified as a dangerous good under transport regulations

Air transport IATA/ICAO

Not classified as a dangerous good under transport regulations

15. Regulatory information

Federal Regulations

Safety data sheet F200 Revision date : 2008/12/04 Version: 3.0

Skin irritation:

Information on: Aluminum oxide rabbit: non-irritant (OECD Guideline 404)

----------------------------------

12. Ecological information

Page: 4/5 (30286124/MDS_GEN_US/EN)

Desiccant Material Safety Data Sheet

Page 26: Compressed Air Dryer Technology - Installation and Operation … · 2017-11-15 · Aircel LLC. reserves the right to change design and specifications without prior notice. Installation,

26

Desiccant Material Safety Data Sheet

HMIS uses a numbering scale ranging from 0 to 4 to indicate the degree of hazard. A value of zero means that the substance possesses essentially no hazard; a rating of four indicates high hazard.

Local contact information [email protected]

IMPORTANT: WHILE THE DESCRIPTIONS, DESIGNS, DATA AND INFORMATION CONTAINED HEREIN ARE PRESENTED IN GOOD FAITH AND BELIEVED TO BE ACCURATE , IT IS PROVIDED FOR YOUR GUIDANCE ONLY. BECAUSE MANY FACTORS MAY AFFECT PROCESSING OR APPLICATION/USE, WE RECOMMEND THAT YOU MAKE TESTS TO DETERMINE THE SUITABILITY OF A PRODUCT FOR YOUR PARTICULAR PURPOSE PRIOR TO USE. NO WARRANTIES OF ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, ARE MADE REGARDING PRODUCTS DESCRIBED OR DESIGNS, DATA OR INFORMATION SET FORTH, OR THAT THE PRODUCTS, DESIGNS, DATA OR INFORMATION MAY BE USED WITHOUT INFRINGING THE INTELLECTUAL PROPERTY RIGHTS OF OTHERS. IN NO CASE SHALL THE DESCRIPTIONS, INFORMATION, DATA OR DESIGNS PROVIDED BE CONSIDERED A PART OF OUR TERMS AND CONDITIONS OF SALE. FURTHER, YOU EXPRESSLY UNDERSTAND AND AGREE THAT THE DESCRIPTIONS, DESIGNS, DATA, AND INFORMATION FURNISHED BY BASF HEREUNDER ARE GIVEN GRATIS AND BASF ASSUMES NO OBLIGATION OR LIABILITY FOR THE DESCRIPTION, DESIGNS, DATA AND INFORMATION GIVEN OR RESULTS OBTAINED, ALL SUCH BEING GIVEN AND ACCEPTED AT YOUR RISK. END OF DATA SHEET

Safety data sheet F200 Revision date : 2008/12/04 Version: 3.0

Registration status: TSCA, US

OSHA hazard category:

Page: 5/5 (30286124/MDS_GEN_US/EN)

State RTK MA, NJ, PA

released / listed

ACGIH TLV established

SARA hazard categories (EPCRA 311/312): Acute

SARA 313:

CAS Number 1333-84-2

State regulations

State RTK

CAS Number 1333-84-2

Chemical name Aluminum oxide (Al2O3), hydrate

Chemical name Aluminum oxide (Al2O3), hydrate

16. Other information

HMIS III rating Health: 1 Flammability: 0 Physical hazard: 1

AircelAHLDE-Series-Models70-750

Page 27: Compressed Air Dryer Technology - Installation and Operation … · 2017-11-15 · Aircel LLC. reserves the right to change design and specifications without prior notice. Installation,

Systemdisplayshowsthedryeroperationsandprovidestheusertheabilitytochangecertaindryersettings.

27

HeatlessRegenerativeDesiccantAirDryer

Aircel Programmable Controller

Text Display

DEL Key

ESC Key

Left Arrow Key

Down Arrow Key

On Key * Key

Right Arrow Key

Up Arrow Key

ALT Key

Red LED: Common alarm light

Standard alarms: EMS Humidity Probe failure and Drain fault

Optional alarms: High Humidity, Dew Point probe failure and Failure to Shift

Red LED: Energy Savings Active Light

Page 28: Compressed Air Dryer Technology - Installation and Operation … · 2017-11-15 · Aircel LLC. reserves the right to change design and specifications without prior notice. Installation,

Step 1: Vessel 2 Depressurizing (0-5 secs) Vessel2(T2)purgeexhaustpilotsolenoidvalveisenergizedwhich suppliescontrolairtothepurgeexhaustvalve(V4)whichopens slowly,depressurizingvessel2(T2).Simultaneouslytheinletand outletAPV(AutomaticPistonValveV1&V2)shiftpositions directingtheinletairtovessel1(T1)tobedryingtheair.Theair flowsupthroughthedesiccantbedandexitstotheoutletAPV valve(V2)totheoutletparticulatefilterthentothecustomer dry process air system.

Step 2: Vessel 2 Regenerating (6-240 secs)Step2isacontinuationofstep1exceptvessel2(T2)willbe regenerating,vessel2(T2)purgeexhaustvalve(V4)isstillopen, vessel1(T1)isdryingtheinletair.Asmallportionofdryoutletair fromvessel1(T1)(15%averagebasedonstandarddesigncapacity of100psig,100°Finletair,100°FambientairandPDPof-40°F)is takenthroughasmallorificeintheoutletAPVvalve(V2)andusedtoregeneratethedesiccantbed

invessel2(T2)until240secondshasbeenreached.Thescreenalsoshowstherelativehumidityreadingaswellasthe(optional)dewpointwhenapplicable.Thetimeronthisstepcountsto240seconds(4-minutes).Thereisawarningsignthatwillflashintheupperrighthandportionofthescreenforanyalarm.ThereisalsoaredLEDalarmlightthatwillflashonthePLCdisplayforanyalarm.Theusermustscrolltothealarmscreentoviewthealarms(presstheleftarrowoncefromthemainscreentoviewthealarmscreen).

Step 3: Vessel 2 Repressurizing (241-300 secs) Vessel2(T2)purgeexhaustpilotsolenoidvalvewillde-energize causingvessel2(T2)purgeexhaustvalve(V4)toclose,this allowsvessel2(T2)torepressurizetolinepressure,sinceair continuesflowingthoughthesmallorificeintheoutletAPV valve(V2)pressurizingvessel2(T2).

Step 4: Extended Drying Vessel 1 AfewsecondsbeforetheendofrepressurizationtheAHLD E-SERIESController’sintegratedEnergyManagementPurge ReductionSystemlooksatthemoisturesensor,ifthemoisture loadislowenough,vessel1(T1)willcontinuetodryforan extendeddryingperioduntilthemoistureloadhasreacheda sethighlevel,thecontrollerwillthenadvancetostep5andthe vessels will switch. This feature reduces the overall purge consumption saving energy and money.

Theextendeddryingcycletimerwillcountto30minutesunlesstheEMSrelativehumiditysensorishigherthanthesetpoint.After30minutes,theunitwillswitchandcontinuenormaloperationuntilthenextextendedsavingsstep.AtthestartofeachextendedsavingsstepthePLCchecksforfaults,EMSrelativehumiditysensorvalueandhighoutletdewpointsetting(optional)toensureifthedryerneedstocontinuedryingandthedryerwillgointoextendeddrying.Ifthedryerneedstocontinuetothenextsteptoregenerate,theextendedsavingsstep4willbeskipped.

28

Aircel Programmable Controller

 

 

 

 

AircelAHLDE-Series-Models70-750

Page 29: Compressed Air Dryer Technology - Installation and Operation … · 2017-11-15 · Aircel LLC. reserves the right to change design and specifications without prior notice. Installation,

Step 5: Vessel 1 Depressurizing (0-5 secs)Vessel1(T1)purgeexhaustpilotsolenoidvalveisenergized whichsuppliescontrolairtothepurgeexhaustvalve(V3)which opensslowly,depressurizingvessel1(T1).Simultaneouslythe inletandoutletAPV(AutomaticPistonValveV1&V2)shift positionsdirectingtheinletairtovessel2(T2)tobedryingtheair. Theairflowsupthroughthedesiccantbedandexitstotheoutlet APVvalve(V2)totheoutletparticulatefilterthentothecustomer dry process air system.

Step 6: Vessel 1 Regenerating (6-240 secs)Step6isacontinuationofstep5exceptvessel1(T1)willbe regenerating,vessel1(T1)purgeexhaustvalve(V3)isstillopen, vessel2(T2)isdryingtheinletair.Asmallportionofdryoutlet airfromvessel2(15%averagebasedonstandarddesign capacityof100psig,100°Finletair,100°Fambientairand PDPof-40°F)istakenthroughasmallorificeintheoutlet APVvalve(V2)andusedtoregeneratethedesiccantbedin vessel1(T1)until240secondshasbeenreached.

Step 7: Vessel 1 Repressurizing (241-300 secs)Vessel1(T1)purgeexhaustpilotsolenoidvalvewillde-energize causingvessel1purgeexhaustvalve(V3)toclose,thisallows vessel1(T1)torepressurizetolinepressure,sinceaircontinuesflowingthoughthesmallorificeintheoutletAPVvalve(V2) pressurizingvessel1(T1).

Step 8: Extended Drying Vessel 2AfewsecondsbeforetheendofrepressurizationtheAHLD E-SERIESController’sintegratedEnergyManagementPurge ReductionSystemlooksatthemoisturesensor,ifthemoisture loadislowenough,vessel2(T2)willcontinuetodryfor anextendeddryingperioduntilthemoistureloadhasreached asethighlevel,thecontrollerwillthenadvancetostep1and the vessels will switch. This feature reduces the overall purge consumptionsavingenergyandmoney.Theextendeddryingcycle

timerwillcountto30minutesunlesstheEMSrelativehumiditysensorishigherthanthesetpoint.After30minutes,theunitwillswitchandcontinuenormaloperationuntilthenextextendedsavingsstep.AtthestartofeachextendedsavingsstepthePLCchecksforfaults,EMSrelativehumiditysensorvalueandhighoutletdewpointsetting(optional)toensureifthedryerneedstocontinuedryingandthedryerwillgointoextendeddrying.Ifthedryerneedstocontinuetothenextsteptoregenerate,theextendedsavingsstep4willbeskipped.

29

HeatlessRegenerativeDesiccantAirDryer

Aircel Programmable Controller

 

 

 

 

Page 30: Compressed Air Dryer Technology - Installation and Operation … · 2017-11-15 · Aircel LLC. reserves the right to change design and specifications without prior notice. Installation,

30

Aircel Programmable Controller

Main Screen Navigation

  LEFT/RIGHT LEFT/RIGHT

ALARM  SCREEN CONTROL  MENU

Control Menu Navigation

 

LEFT/RIGHT LEFT/RIGHT

MAIN  SCREEN SETTINGS  MENU  

AircelAHLDE-Series-Models70-750

Page 31: Compressed Air Dryer Technology - Installation and Operation … · 2017-11-15 · Aircel LLC. reserves the right to change design and specifications without prior notice. Installation,

HeatlessRegenerativeDesiccantAirDryer

31

Aircel Programmable Controller

Control Menu Operation

Settings Screen OperationForusewithoptionaloutletdewpointdisplayandhighhumidityalarm.

 

CONTROL  MENU

• Push OK to engage the menu

• Scroll to the desired selection and Push OK

  SETTINGS  SCREEN • To engage, Push OK then scroll to the desired

set point to be changed

• Push OK on the set point to be changed and use the up or down arrows to change the set point

• Push OK to complete the change and ESC to de-select the screen. Push ESC again to exit to the main screen or use the left or right arrows to scroll to the next screen.

Page 32: Compressed Air Dryer Technology - Installation and Operation … · 2017-11-15 · Aircel LLC. reserves the right to change design and specifications without prior notice. Installation,

32

Aircel Programmable Controller

Time Control Menu Navigation Thistimecyclecontrolmenuallowstheusertochoosebetweena10minutestandardtimecycleandashorter5minutecycleforlowerdewpointoption.

Time Control Menu Operation

 

LEFT/RIGHT LEFT/RIGHT

TIME  CYCLE  CONTROL

     SETTINGS  MENU   ANALOG  SCREEN

  TIME  CONTROL  MENU • To change the time cycle, Push OK then scroll

to the time cycle to be selected. Push OK then Push ESC.

• When changes are complete, Push ESC to exit changes. Push ESC again to return to the main screen.

AircelAHLDE-Series-Models70-750

Page 33: Compressed Air Dryer Technology - Installation and Operation … · 2017-11-15 · Aircel LLC. reserves the right to change design and specifications without prior notice. Installation,

 

LEFT/RIGHT LEFT/RIGHT

HOURS  OF  OPERATION TIME  CONTROL  SCREEN

ANALOG  SCREEN

HeatlessRegenerativeDesiccantAirDryer

33

Aircel Programmable Controller

Analog Screen Navigation The analog screen simply displays the analog output signals

Hours of Operation Screen NavigationThe hours of operation screen gives the user the amount of run time as well as the total amount of hours saved with the energy management system.

 

LEFT/RIGHT LEFT/RIGHT

ANALOG  SCREEN

HOURS  OF  OPERATION

ALARM  SCREEN

Page 34: Compressed Air Dryer Technology - Installation and Operation … · 2017-11-15 · Aircel LLC. reserves the right to change design and specifications without prior notice. Installation,

34

Aircel Programmable Controller

Alarm Pop-Ups

• No Alarm: alarm has been corrected• High Out Dew Point (option):dewpointhasresearchedsetpoint(checkdesiccant,prefilters,

controlsystem)• Failure to Shift (option): tower did not properly repressurize• Bad Probe:theEMSsensorhasreachedanoutofrangesignal(checksensorandcable)

Alarm Screen Navigation

 

LEFT/RIGHT LEFT/RIGHT

MAIN  MENU TOTAL  HOURS  OF  OPERATION  

ALARM  SCREEN

AircelAHLDE-Series-Models70-750

Page 35: Compressed Air Dryer Technology - Installation and Operation … · 2017-11-15 · Aircel LLC. reserves the right to change design and specifications without prior notice. Installation,

HeatlessRegenerativeDesiccantAirDryer

35

Aircel Programmable Controller

Alarm Pop-Up Screens

No Alarm is the normally closed state of the common alarm relay.

The Drain Fault is an alarm that triggers when there is no air present on the drain or when the liquid level has reached a point thatneedstoDrainandcannot.Thedrainwillalsofaultifthereisa loss of power to the drain.

The Bad RH Probe is an alarm that shows when the relative humidity(EMS)probeisoutofrange.Thiscanbeeitherhighoutof range or low out of range. When this happens, the signal has either been lost or the sensor may need to be replaced.

The Bad DEW-P Probe is the alarm for the dew point sensor probe out of range. The out of range can be either high or low. This can be either a complete loss of signal/voltage, the resistor can be disconnected or the sensor may need to be calibrated.

The High Humidity Alarm is an alarm that is visible when the dew point is higher than the set point. The set point for the high humidity alarm can be changed but it is not recommended.

The FTS Alarm (Failure-to-Shift) is an alarm that is present when a vessel does not depressurize correctly or if a vessel that is to be drying does not have a pressure at or above a certain set pressure.

 

 

 

 

 

 

Page 36: Compressed Air Dryer Technology - Installation and Operation … · 2017-11-15 · Aircel LLC. reserves the right to change design and specifications without prior notice. Installation,

36

Electrical Drawings

Main Power & PLC Input: All AHLD E Models

AircelAHLDE-Series-Models70-750

Page 37: Compressed Air Dryer Technology - Installation and Operation … · 2017-11-15 · Aircel LLC. reserves the right to change design and specifications without prior notice. Installation,

HeatlessRegenerativeDesiccantAirDryer

37

Electrical Drawings

Main Power & PLC Input: All AHLD E Models

Page 38: Compressed Air Dryer Technology - Installation and Operation … · 2017-11-15 · Aircel LLC. reserves the right to change design and specifications without prior notice. Installation,

38

Electrical Drawings

PLC Output & Sensors: All AHLD E Models

AircelAHLDE-Series-Models70-750

Page 39: Compressed Air Dryer Technology - Installation and Operation … · 2017-11-15 · Aircel LLC. reserves the right to change design and specifications without prior notice. Installation,

HeatlessRegenerativeDesiccantAirDryer

39

Electrical Drawings

PLC Output & Sensors: All AHLD E Models

Page 40: Compressed Air Dryer Technology - Installation and Operation … · 2017-11-15 · Aircel LLC. reserves the right to change design and specifications without prior notice. Installation,

40

Electrical Drawings

Back Panel: All AHLD E Models

AircelAHLDE-Series-Models70-750

Page 41: Compressed Air Dryer Technology - Installation and Operation … · 2017-11-15 · Aircel LLC. reserves the right to change design and specifications without prior notice. Installation,

HeatlessRegenerativeDesiccantAirDryer

41

Electrical Drawings

Enclosure Layout: All AHLD E Models

Page 42: Compressed Air Dryer Technology - Installation and Operation … · 2017-11-15 · Aircel LLC. reserves the right to change design and specifications without prior notice. Installation,

42

Service Notes

Date Service Performed Notes

AircelAHLDE-Series-Models70-750

Page 43: Compressed Air Dryer Technology - Installation and Operation … · 2017-11-15 · Aircel LLC. reserves the right to change design and specifications without prior notice. Installation,

Service Notes

Date Service Performed Notes

HeatlessRegenerativeDesiccantAirDryer

43

Page 44: Compressed Air Dryer Technology - Installation and Operation … · 2017-11-15 · Aircel LLC. reserves the right to change design and specifications without prior notice. Installation,

©2012AircelLLC. PrintedinUSAJune2012

Aircel LLC.323 Crisp CircleMaryville,[email protected]@AircelDryers.com

www.AircelDryers.com

Aircel Compressed Air & Gas Warranty

AircelLLC.warrantsitsstandardRefrigeratedDryers,DesiccantDryers,Chillers,andNitrogenGeneratorsarefreefromdefectsinmaterialsandworkmanshipfortwoyearsfromdateofinvoice.AllotherAircelLLC.standardproducts(filters,drains,aftercoolers,oil/waterseparators,spareparts,andcomponents)andcustomengineeredproductsarewarrantedtobefreefromdefectsinmaterialsandworkmanshipforoneyearfromdateofinvoice.TheAircelLLC.Warrantyexcludesdamagesdueto:corrosion,lackofpropermaintenance,incorrectinstallation,modification,ormisapplicationofequipment. Routine maintenance or adjustments required under normal operation as outlined in the Aircel LLC. operation and maintenance manuals are not covered under warranty. After Aircel LLC. hasbeengivenadequateopportunitytoremedyanydefectsinmaterialorworkmanshipinaccordancewithAircelLLC.WarrantyPolicyandProcedures,AircelLLC.retainsthesoleoptiontoacceptthereturn of the goods, with freight paid by the purchaser, and to refund the purchase price for the goods afterconfirmingthegoodsarereturnedundamagedandinusablecondition.SucharefundwillbethefullextentofAircelLLC’s.liability.AircelLLC.shallnotbeliableforanyothercosts,expensesor damages whether direct, indirect, special, incidental, consequential or otherwise. The terms of this warrantymaybemodifiedonlybyaspecialwarrantydocumentsignedbythePresidentofAircelLLC.THEREEXISTNOOTHERREPRESENTATIONS,WARRANTIESORGUARANTEESEXCEPTASSTATEDINTHISPARAGRAPHANDALLOTHERWARRANTIESINCLUDINGMERCHANTABILITYANDFITNESSFORAPARTICULARPURPOSE,WHETHEREXPRESSORIMPLIEDAREHEREBYEXPRESSLYEXCLUDEDANDDISCLAIMED.

Parts and ServiceForgenuineAircelreplacementparts,call:

800-767-4599www.AircelDryers.com

Forfasterservice,haveunit’smodelandserialnumber,part number, description, and quantity available.

Aircel LLC. is a leading designer and manufacturer of dryer systems and components.