COMPREHENSIVE ASBESTOS INSPECTION 3180 F ROAD GRAND JUNCTION, COLORADO Inspected by Grande River Environmental, LLC CDPHE CONSULTING FIRM #18631 May 7, 2018

Transcript of COMPREHENSIVE ASBESTOS INSPECTION 3180 F ROAD GRAND ... · potential for cross-contamination...

Page 1: COMPREHENSIVE ASBESTOS INSPECTION 3180 F ROAD GRAND ... · potential for cross-contamination between samples. The sampler assumed that materials in ... Accessible spaces were inspected

COMPREHENSIVE ASBESTOS INSPECTION 3180 F ROAD

GRAND JUNCTION, COLORADO

Inspected by Grande River Environmental, LLC CDPHE CONSULTING FIRM #18631

May 7, 2018

Page 2: COMPREHENSIVE ASBESTOS INSPECTION 3180 F ROAD GRAND ... · potential for cross-contamination between samples. The sampler assumed that materials in ... Accessible spaces were inspected

May 7, 2018

COMPREHENSIVE ASBESTOS INSPECTION

3180 F ROAD GRAND JUNCTION, COLORADO

May 7, 2018

Prepared for: Tim Davis Mesa County Libraries

443 North 6th Street Grand Junction, Colorado Prepared by: ______________________________________________________

Travis Brophy, APCD # 13477 Certified Asbestos Inspector

Reviewed by:

Faron Compton, APCD #4166 Certified Asbestos Inspector

Submitted by Grande River Environmental, LLC

Clifton, Colorado 81520 (970) 628-1196

Page 3: COMPREHENSIVE ASBESTOS INSPECTION 3180 F ROAD GRAND ... · potential for cross-contamination between samples. The sampler assumed that materials in ... Accessible spaces were inspected

May 7, 2018

TABLE OF CONTENTS

1 INTRODUCTION..............................................................................................................1

2 ASBESTOS INSPECTION ...............................................................................................1

2.1 Asbestos Sampling Strategy ................................................................................................2 2.2 Asbestos Laboratory Analyses .............................................................................................2 2.3 Asbestos Chain-of-Custody .................................................................................................3

3 ASBESTOS INSPECTION RESULTS ............................................................................3

4 CONCLUSIONS & RECOMMENDATIONS ................................................................4

5 QUALIFICATIONS AND LIMITATIONS ....................................................................5

LIST OF TABLES

TABLE 1 BULK SAMPLING STRATEGY ...........................................................................2 TABLE 2 ASBESTOS INSPECTION RESULTS ...................................................................3

LIST OF APPENDICES

APPENDIX A ASBESTOS SAMPLING FORMS APPENDIX B ASBESTOS ANALYTICAL DATA, CHAIN-OF-CUSTODY FORMS APPENDIX C INSPECTOR CERTIFICATIONS

Page 4: COMPREHENSIVE ASBESTOS INSPECTION 3180 F ROAD GRAND ... · potential for cross-contamination between samples. The sampler assumed that materials in ... Accessible spaces were inspected

May 7, 2018 1

COMPREHENSIVE ASBESTOS INSPECTION 3180 F ROAD

GRAND JUNCTION, COLORADO

1 INTRODUCTION

Grande River Environmental, LLC (GRE) was contracted by Mesa County Library District to conduct an asbestos inspection of the residential structure located at 3180 F Road in Grand Junction, Colorado. The inspection was conducted in accordance with applicable Environmental Protection Agency (EPA), Occupational Safety and Health Administration (OSHA), and Colorado Department of Public Health and Environment (CDPHE) regulations prior to demolition of the structure. The purpose of this report is to present the findings of the inspection conducted on May 1, 2018.

2 ASBESTOS INSPECTION

Asbestos sampling was completed by Travis Brophy, a GRE asbestos inspector certified by the CDPHE and the EPA. Copies of the inspector’s certifications are attached to this report. This survey was performed in accordance with CDPHE Regulation No. 8 and AHERA regulations governing asbestos inspections. An asbestos inspection is required prior to conducting demolition or renovation activities. Bulk samples of various suspect asbestos-containing materials (ACM) were collected and submitted to an independent laboratory for polarized-light microscopic (PLM) analysis. Sample locations are described on the attached sample data sheets. Asbestos sampling is conducted by segregating building materials into sampling units called homogeneous areas. A homogeneous area is defined as a material that is uniform in texture and color and appears identical in every other respect. Once suspect materials are identified, they are classified as friable or non-friable. The EPA distinguishes between friable and non-friable forms of ACMs. Friable materials, when dry, can be crumbled or reduced to powder by hand pressure, whereas non-friable materials cannot. Friable materials are more likely to release particulate dust into the air, especially during renovation and demolition activities. Therefore, the distinction between friable and non-friable homogeneous material is important. Non-friable materials are further divided into two categories as defined by EPA. Category I non-friable materials that are in good condition may remain during building demolition provided these materials are not rendered friable during demolition. Category II non-friable materials must be removed prior to conducting renovation or demolition activities.

Page 5: COMPREHENSIVE ASBESTOS INSPECTION 3180 F ROAD GRAND ... · potential for cross-contamination between samples. The sampler assumed that materials in ... Accessible spaces were inspected

May 7, 2018 2

2.1 Asbestos Sampling Strategy

The Bulk Sampling Strategy shown in Table 1 was developed based on EPA and CDPHE regulations and was used to determine the minimum number of samples to be collected of each suspect material. TABLE 1 – BULK SAMPLING STRATEGY

MATERIAL HOMOGENEOUS

AREA SIZE UNITS MINIMUM NUMBER

OF SAMPLES

Surfacing Less than 1,000 SF 3

1,000 to 5,000 SF 5

More than 5,000 SF 7 Thermal System Insulation - - - LF / SF / EA 3

Miscellaneous Materials - - - LF / SF / EA 1 Note: SF = Square feet LF = Linear feet EA = Each GRE collected bulk samples of the homogeneous materials in a random and representative manner, as determined by the inspector. A minimum of one composite core sample that included all layers within the suspect material was obtained from each homogeneous area. Samples from soft friable materials were obtained by removing a small portion using wetting techniques. The sampler washed equipment following collection of each sample in order to minimize the potential for cross-contamination between samples. The sampler assumed that materials in inaccessible locations were similar to those in accessible locations, in order to limit the amount of destruction in the sampling process. All samples were placed in sealed, labeled containers, and the sample descriptions and locations were recorded. Accessible spaces were inspected for homogeneous areas of building materials that potentially contain asbestos. The nature, extent, and condition of each type of potential ACM were cataloged. Sampling forms for each homogeneous area were prepared describing the type of material, identifying characteristics, and location of the sample. These forms are included in Appendix A of this report.

2.2 Asbestos Laboratory Analyses

Samples were submitted to an independent laboratory for analysis. Collected samples were analyzed by Reservoirs Environmental Services, Inc. (NVLAP Accreditation No. 101896) of Denver, Colorado, using polarized-light microscopy (PLM), a bulk sample analysis method established by the National Voluntary Laboratory Accreditation Program (NVLAP). Bulk asbestos samples were analyzed using EPA Method 600/R-93/116. While the EPA does not “certify” laboratories, analytical methods follow EPA’s recommended protocols using a NVLAP accredited laboratory. The laboratory analytical data report is attached.

Page 6: COMPREHENSIVE ASBESTOS INSPECTION 3180 F ROAD GRAND ... · potential for cross-contamination between samples. The sampler assumed that materials in ... Accessible spaces were inspected

May 7, 2018 3

2.3 Asbestos Chain-of-Custody

A chain-of-custody record was used to track the possession and transfer of each sample from the time of field collection through laboratory analysis. The record contained the following: sample tag number, signature of collector, date of collection, identification of sampled material, requested laboratory analysis, signatures of individuals in custody of the samples, and record of possession. A copy of the chain-of-custody form is attached.

3 ASBESTOS INSPECTION RESULTS

Laboratory results from the asbestos inspection are summarized below. Samples of materials that contain greater than one percent (>1%) asbestos are considered ACM by the EPA and CDPHE. Samples that contain any amount of asbestos greater than none detected (ND) are recognized and covered by the OSHA Asbestos in Construction Standard found at 29 CFR 1926.1101. Homogeneous material descriptions, locations, and quantities as well as analytical results are summarized in Table 2.

TABLE 2 – ASBESTOS INSPECTION RESULTS

HA MATERIAL DESCRIPTION

ASBESTOS CONTENT LOCATION QUANTITY

01 Drywall with Joint Compound 3% chrysotile

Northwest entry ceiling, northeast bedroom walls, walls and ceiling in kitchen and

southeast bedroom 650 SF

02

Drywall with Joint Compound and Spray Applied

Texture

4% chrysotile Walls and ceiling in bathroom 200SF

03 Brown Cove Base ND Bathroom 10 LF

04 Mosaic Pattern Linoleum ND Living room beneath carpet 250 SF

05 4” Brown Cove Base ND Living room 40 LF

06 Wall Paper with Float ND Living room walls behind celotex 500 SF

07 Brick Pattern Linoleum ND Kitchen 250 SF

08 Green Linoleum 25% chrysotile Kitchen beneath HA 07 250 SF

09 Green Countertop 35% chrysotile Kitchen counter and backspash 12 SF

10 Brick Asphalt Siding with Tar Paper ND Exterior siding 1,700 SF

Page 7: COMPREHENSIVE ASBESTOS INSPECTION 3180 F ROAD GRAND ... · potential for cross-contamination between samples. The sampler assumed that materials in ... Accessible spaces were inspected

May 7, 2018 4

HA MATERIAL DESCRIPTION

ASBESTOS CONTENT LOCATION QUANTITY

11 Heater PACM Living room unit 1 UNIT

12 Transite PACM Near chimney in kitchen, around exterior of structure 10 SF

13 Wire Insulation PACM Throughout house 200 LF

14 Roofing Materials PACM Roof 1,000 SF

NOTES: HA – Homogeneous Area SF – Square Feet LF – Linear Feet PACM– Presumed Asbestos Containing Material Bold – Regulated Asbestos-Containing Material Italic – Sub-regulated Asbestos-Containing Material Listed quantities are approximate.

4 CONCLUSIONS & RECOMMENDATIONS

This report presents the findings of an asbestos inspection conducted on May 1, 2018 at 3180 F Road in Grand Junction, Colorado in accordance with EPA and CDPHE regulations. The objective of this inspection was to identify the location and extent of asbestos-containing materials (ACMs) prior to demolition of the structure. Bulk samples of suspect ACMs were obtained from the structure and submitted to an independent laboratory for polarized-light microscopic (PLM) analysis. Following are the recommendations to handle the materials based on their asbestos content, friability, and category: Drywall System, Linoleum, Countertop and Heater – These material were identified or assumed to contain more than one percent asbestos and are considered friable ACMs. These material requires removal by a certified abatement contractor prior to conducting renovation or demolition activities. Removal activities must be performed by a qualified asbestos removal contractor who possesses a current Colorado General Abatement Certificate in accordance with procedures outlined in EPA and Colorado Regulation No. 8. Removed materials must be properly packaged, labeled, and disposed as asbestos waste at an approved solid waste facility. Transite – The transite in the kitchen and around the exterior of the structure was assumed to contain asbestos. Theses materials were in good condition at the time of the inspection and are non-friable. Removal should be completed by a qualified asbestos removal contractor who

Page 8: COMPREHENSIVE ASBESTOS INSPECTION 3180 F ROAD GRAND ... · potential for cross-contamination between samples. The sampler assumed that materials in ... Accessible spaces were inspected

May 7, 2018 5

possesses a current Colorado General Abatement Certificate in accordance with procedures outlined in EPA and Colorado Regulation No. 8. Removed materials must be properly packaged, labeled, and disposed as asbestos waste at an approved solid waste facility. Wire Insulation and Roofing Materials – The tar impregnated wire insulation and roofing materials were assumed to contain asbestos and are considered non-friable. In accordance with Section III.S.3 of Colorado Regulation No. 8, Part B, tar impregnated roofing materials that are non-friable and will remain non-friable during abatement are exempt for the regulation and in accordance with Section 29 CFR 1926.1101 (a)(8) of the OSHA Asbestos in Construction Standard, the regulation does not apply to asbestos-containing roof coatings. Therefore, so long as the materials remain non-friable during renovation or demolition activities, removal does not require a certified asbestos abatement contractor. Mechanical demolition of structures does not ordinarily make tar impregnated wire insulation or roofing materials friable.

5 QUALIFICATIONS AND LIMITATIONS

This assessment was limited to the sampling locations and analyses described in the report. No other sampling or analyses were conducted during this investigation. It is possible that additional reports or investigations could alter the conclusions of this assessment. This report is intended for use only by the client. Any future use of this report by anyone other than the above-referenced client will require authorization by GRE and possible updating of the report. The quantities listed in this report are estimated; this report is not intended to be used as a bidding document to remove asbestos.

Page 9: COMPREHENSIVE ASBESTOS INSPECTION 3180 F ROAD GRAND ... · potential for cross-contamination between samples. The sampler assumed that materials in ... Accessible spaces were inspected

May 7, 2018

APPENDIX A

ASBESTOS SAMPLING FORMS

Page 10: COMPREHENSIVE ASBESTOS INSPECTION 3180 F ROAD GRAND ... · potential for cross-contamination between samples. The sampler assumed that materials in ... Accessible spaces were inspected
Page 11: COMPREHENSIVE ASBESTOS INSPECTION 3180 F ROAD GRAND ... · potential for cross-contamination between samples. The sampler assumed that materials in ... Accessible spaces were inspected
Page 12: COMPREHENSIVE ASBESTOS INSPECTION 3180 F ROAD GRAND ... · potential for cross-contamination between samples. The sampler assumed that materials in ... Accessible spaces were inspected
Page 13: COMPREHENSIVE ASBESTOS INSPECTION 3180 F ROAD GRAND ... · potential for cross-contamination between samples. The sampler assumed that materials in ... Accessible spaces were inspected
Page 14: COMPREHENSIVE ASBESTOS INSPECTION 3180 F ROAD GRAND ... · potential for cross-contamination between samples. The sampler assumed that materials in ... Accessible spaces were inspected
Page 15: COMPREHENSIVE ASBESTOS INSPECTION 3180 F ROAD GRAND ... · potential for cross-contamination between samples. The sampler assumed that materials in ... Accessible spaces were inspected
Page 16: COMPREHENSIVE ASBESTOS INSPECTION 3180 F ROAD GRAND ... · potential for cross-contamination between samples. The sampler assumed that materials in ... Accessible spaces were inspected
Page 17: COMPREHENSIVE ASBESTOS INSPECTION 3180 F ROAD GRAND ... · potential for cross-contamination between samples. The sampler assumed that materials in ... Accessible spaces were inspected
Page 18: COMPREHENSIVE ASBESTOS INSPECTION 3180 F ROAD GRAND ... · potential for cross-contamination between samples. The sampler assumed that materials in ... Accessible spaces were inspected
Page 19: COMPREHENSIVE ASBESTOS INSPECTION 3180 F ROAD GRAND ... · potential for cross-contamination between samples. The sampler assumed that materials in ... Accessible spaces were inspected
Page 20: COMPREHENSIVE ASBESTOS INSPECTION 3180 F ROAD GRAND ... · potential for cross-contamination between samples. The sampler assumed that materials in ... Accessible spaces were inspected
Page 21: COMPREHENSIVE ASBESTOS INSPECTION 3180 F ROAD GRAND ... · potential for cross-contamination between samples. The sampler assumed that materials in ... Accessible spaces were inspected
Page 22: COMPREHENSIVE ASBESTOS INSPECTION 3180 F ROAD GRAND ... · potential for cross-contamination between samples. The sampler assumed that materials in ... Accessible spaces were inspected
Page 23: COMPREHENSIVE ASBESTOS INSPECTION 3180 F ROAD GRAND ... · potential for cross-contamination between samples. The sampler assumed that materials in ... Accessible spaces were inspected
Page 24: COMPREHENSIVE ASBESTOS INSPECTION 3180 F ROAD GRAND ... · potential for cross-contamination between samples. The sampler assumed that materials in ... Accessible spaces were inspected

May 7, 2018

APPENDIX B

ASBESTOS ANALYTICAL DATA CHAIN-OF-CUSTODY FORMS

Page 25: COMPREHENSIVE ASBESTOS INSPECTION 3180 F ROAD GRAND ... · potential for cross-contamination between samples. The sampler assumed that materials in ... Accessible spaces were inspected

Reservoirs Environmental, Inc.

Reservoirs Environmental QA Manual

Effective April 2, 2018

Q:\QAQC\Lab\Reservoirs Environmental QA Manual.doc

Subcontract Number: NA

Laboratory Report: RES 407433-1

Project # / P.O. #  None Given

Project Description: 3180 F Road

RES 407433-1

Sincerely,

May 3, 2018

Dear Customer,

Reservoirs Environmental, Inc. is an analytical laboratory accredited for the analysis of Industrial Hygiene and

Environmental matrices by the National Voluntary Laboratory Accreditation Program (NVLAP), Lab Code 101896-0

for Transmission Electron Microscopy (TEM) and Polarized Light Microscopy (PLM) analysis and the American

Industrial Hygiene Association (AIHA), Lab ID 101533 - Accreditation Certificate #480 for Phase Contrast

Microscopy (PCM) analysis. This laboratory is currently proficient in both Proficiency Testing and PAT programs

respectively.

Reservoirs Environmental, Inc. has analyzed the following samples for asbestos content as per your request. The

analysis has been completed in general accordance with the appropriate methodology as stated in the attached

analysis table. The results have been submitted to your office.

Grande River Environmental

562 Huntington Point Lane

Clifton CO 81520

Jake Harris

is the job number assigned to this study. This report is considered highly confidential

and the sole property of the customer. Reservoirs Environmental, Inc. will not discuss any part of this study with

personnel other than those of the client. The results described in this report only apply to the samples analyzed.

This report must not be used to claim endorsement of products or analytical results by NVLAP or any agency of the

U.S. Government. This report shall not be reproduced except in full, without written approval from Reservoirs

Environmental, Inc. Samples will be disposed of after sixty days unless longer storage is requested. If you have any

questions about this report, please feel free to call 303-964-1986.

Jeanne Spencer

President

P: 303-964-1986

F: 303-477-4275

5801 Logan Street, Suite 100 Denver, CO 80216

Page 1 of 1

1-866-RESI-ENV

www.reilab.com

Page 26: COMPREHENSIVE ASBESTOS INSPECTION 3180 F ROAD GRAND ... · potential for cross-contamination between samples. The sampler assumed that materials in ... Accessible spaces were inspected

RES Job Number:Client:Client Project Number / P.O.:Client Project Description:Date Samples Received:

Turnaround:Date Samples Analyzed:

RES 407433-1Grande River EnvironmentalNone Given3180 F RoadMay 02, 2018

24 HourMay 03, 2018

TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME

Reservoirs Environmental, Inc.Reservoirs Environmental QA Manual

Effective April 2, 2018Q:\QAQC\LAB\Reservoirs Environmental QA Manual.doc

RESERVOIRS ENVIRONMENTAL INC.NVLAP Lab Code 101896-0

Client Sample Number

Lab ID Number

LAYER

Mineral

Method: EPA 600/R-93/116 - Short Report, Bulk

PhysicalDescription

SubPart

(%)

Visual Estimate

(%)

ND=None DetectedTR=Trace, <1% Visual EstimateTrem/Act=Tremolite/Actinolite

NonAsbestosFibrous

Components(%)

Non-Fibrous

Components

(%)

Asbestos Content

821801-1 EM 2077914 White/tan drywall w/ light gray/multi-colored paintA 100 ND 821801-2 EM 2077915 White/tan drywall w/ gray/multi-colored paintA 100 ND

100001-3 EM 2077916 Green/multi-colored paintA 5 ND 970White compoundB 5 3 Chrysotile

595White tapeC 6 ND 970White joint compoundD 7 3 Chrysotile8218White/tan drywallE 77 ND 97002-1 EM 2077917 Off white compoundA 4 3 Chrysotile970Off white micaceous plasterB 4 3 Chrysotile

1000Gray/multi-colored paintC 9 ND 8020White/tan drywallD 83 ND

TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%.

P: 303-964-1986F: 303-477-4275

1-866-RESI-ENVwww.reilab.com

5801 Logan Street, Suite 100, Denver, CO 80216

Page 1 of 5

Page 27: COMPREHENSIVE ASBESTOS INSPECTION 3180 F ROAD GRAND ... · potential for cross-contamination between samples. The sampler assumed that materials in ... Accessible spaces were inspected

RES Job Number:Client:Client Project Number / P.O.:Client Project Description:Date Samples Received:

Turnaround:Date Samples Analyzed:

RES 407433-1Grande River EnvironmentalNone Given3180 F RoadMay 02, 2018

24 HourMay 03, 2018

TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME

Reservoirs Environmental, Inc.Reservoirs Environmental QA Manual

Effective April 2, 2018Q:\QAQC\LAB\Reservoirs Environmental QA Manual.doc

RESERVOIRS ENVIRONMENTAL INC.NVLAP Lab Code 101896-0

Client Sample Number

Lab ID Number

LAYER

Mineral

Method: EPA 600/R-93/116 - Short Report, Bulk

PhysicalDescription

SubPart

(%)

Visual Estimate

(%)

ND=None DetectedTR=Trace, <1% Visual EstimateTrem/Act=Tremolite/Actinolite

NonAsbestosFibrous

Components(%)

Non-Fibrous

Components

(%)

Asbestos Content

97002-2 EM 2077918 Off white compoundA 4 3 Chrysotile970Off white micaceous plasterB 5 3 Chrysotile

1000Gray/multi-colored paintC 7 ND 8020White/tan drywallD 84 ND 97002-3 EM 2077919 Off white compoundA 8 3 Chrysotile

1000Off white/pink paintB 12 ND 960Off white micaceous plasterC 25 4 Chrysotile7525White/tan drywallD 55 ND

100003-1 EM 2077920 Brown adhesiveA 17 ND 1000Brown cove baseB 83 ND 100003-2 EM 2077921 Brown adhesiveA 16 ND 1000Brown cove baseB 84 ND

TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%.

P: 303-964-1986F: 303-477-4275

1-866-RESI-ENVwww.reilab.com

5801 Logan Street, Suite 100, Denver, CO 80216

Page 2 of 5

Page 28: COMPREHENSIVE ASBESTOS INSPECTION 3180 F ROAD GRAND ... · potential for cross-contamination between samples. The sampler assumed that materials in ... Accessible spaces were inspected

RES Job Number:Client:Client Project Number / P.O.:Client Project Description:Date Samples Received:

Turnaround:Date Samples Analyzed:

RES 407433-1Grande River EnvironmentalNone Given3180 F RoadMay 02, 2018

24 HourMay 03, 2018

TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME

Reservoirs Environmental, Inc.Reservoirs Environmental QA Manual

Effective April 2, 2018Q:\QAQC\LAB\Reservoirs Environmental QA Manual.doc

RESERVOIRS ENVIRONMENTAL INC.NVLAP Lab Code 101896-0

Client Sample Number

Lab ID Number

LAYER

Mineral

Method: EPA 600/R-93/116 - Short Report, Bulk

PhysicalDescription

SubPart

(%)

Visual Estimate

(%)

ND=None DetectedTR=Trace, <1% Visual EstimateTrem/Act=Tremolite/Actinolite

NonAsbestosFibrous

Components(%)

Non-Fibrous

Components

(%)

Asbestos Content

604004-1 EM 2077922 Tan/multi-colored flooring w/ green/multi-colored fibrous backing material & brown adhesive

A 100 ND

554504-2 EM 2077923 Tan/multi-colored flooring w/ green/multi-colored fibrous backing material

A 100 ND

100005-1 EM 2077924 Brown cove base w/ tan adhesiveA 100 ND 100005-2 EM 2077925 Brown cove base w/ tan adhesiveA 100 ND

208005-3 EM 2077926 Tan/multi-colored fibrous materialA 100 ND 20806-2 EM 2077927 Tan/multi-colored fibrous materialA 100 ND 802007-1 EM 2077928 Tan/multi-colored sheet vinyl w/ gray/brown fibrous

backing materialA 100 ND

802007-2 EM 2077929 Tan/multi-colored sheet vinyl w/ gray/brown fibrous backing material

A 100 ND

TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%.

P: 303-964-1986F: 303-477-4275

1-866-RESI-ENVwww.reilab.com

5801 Logan Street, Suite 100, Denver, CO 80216

Page 3 of 5

Page 29: COMPREHENSIVE ASBESTOS INSPECTION 3180 F ROAD GRAND ... · potential for cross-contamination between samples. The sampler assumed that materials in ... Accessible spaces were inspected

RES Job Number:Client:Client Project Number / P.O.:Client Project Description:Date Samples Received:

Turnaround:Date Samples Analyzed:

RES 407433-1Grande River EnvironmentalNone Given3180 F RoadMay 02, 2018

24 HourMay 03, 2018

TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME

Reservoirs Environmental, Inc.Reservoirs Environmental QA Manual

Effective April 2, 2018Q:\QAQC\LAB\Reservoirs Environmental QA Manual.doc

RESERVOIRS ENVIRONMENTAL INC.NVLAP Lab Code 101896-0

Client Sample Number

Lab ID Number

LAYER

Mineral

Method: EPA 600/R-93/116 - Short Report, Bulk

PhysicalDescription

SubPart

(%)

Visual Estimate

(%)

ND=None DetectedTR=Trace, <1% Visual EstimateTrem/Act=Tremolite/Actinolite

NonAsbestosFibrous

Components(%)

Non-Fibrous

Components

(%)

Asbestos Content

653508-1 EM 2077930 Gray/multi-layered flooring w/ tan fibrous woven backing material & red resinous material

A 35 ND

750Green/multi-colored sheet vinyl w/ gray fibrous backing material

B 65 25 Chrysotile

100008-2 EM 2077931 Brown adhesiveA 2 ND 6535Gray/multi-colored flooring w/ tan fibrous woven backing

material & red resinous materialB 45 ND

750Green/multi-colored sheet vinyl w/ gray fibrous backing material

C 53 25 Chrysotile

100009-1 EM 2077932 Brown adhesiveA 25 ND 65TRGreen/multi-colored counter topB 75 35 Chrysotile

100009-2 EM 2077933 Brown adhesiveA 20 ND 65TRGreen/multi-colored counter topB 80 35 Chrysotile703010-1 EM 2077934 Tan/multi-colored shingleA 45 ND 3070Black feltB 55 ND

TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%.

P: 303-964-1986F: 303-477-4275

1-866-RESI-ENVwww.reilab.com

5801 Logan Street, Suite 100, Denver, CO 80216

Page 4 of 5

Page 30: COMPREHENSIVE ASBESTOS INSPECTION 3180 F ROAD GRAND ... · potential for cross-contamination between samples. The sampler assumed that materials in ... Accessible spaces were inspected

RES Job Number:Client:Client Project Number / P.O.:Client Project Description:Date Samples Received:

Turnaround:Date Samples Analyzed:

RES 407433-1Grande River EnvironmentalNone Given3180 F RoadMay 02, 2018

24 HourMay 03, 2018

TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME

Reservoirs Environmental, Inc.Reservoirs Environmental QA Manual

Effective April 2, 2018Q:\QAQC\LAB\Reservoirs Environmental QA Manual.doc

RESERVOIRS ENVIRONMENTAL INC.NVLAP Lab Code 101896-0

Client Sample Number

Lab ID Number

LAYER

Mineral

Method: EPA 600/R-93/116 - Short Report, Bulk

PhysicalDescription

SubPart

(%)

Visual Estimate

(%)

ND=None DetectedTR=Trace, <1% Visual EstimateTrem/Act=Tremolite/Actinolite

NonAsbestosFibrous

Components(%)

Non-Fibrous

Components

(%)

Asbestos Content

100010-2 EM 2077935 Black multi-layered tarA 40 ND 3070Black multi-layered feltB 60 ND 257506-3 (Not on Original COC) EM 2077936 Tan/multi-colored multi-layered fibrous materialA 100 ND 752504-1 (Not on Original COC/Duplicate

Sample ID) EM 2077937 Beige/multi-colored sheet vinyl w/ blue fibrous backing

materialA 100 ND

100004-2 (Not on Original COC/Duplicate Sample ID)

EM 2077938 Brown adhesiveA 12 ND

7525Beige/multi-colored sheet vinyl w/ blue fibrous backing material

B 88 ND

TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%.

Analyst / Data QAAnalystAnalystAnalystAnalyst

P: 303-964-1986F: 303-477-4275

1-866-RESI-ENVwww.reilab.com

5801 Logan Street, Suite 100, Denver, CO 80216

Page 5 of 5

Page 31: COMPREHENSIVE ASBESTOS INSPECTION 3180 F ROAD GRAND ... · potential for cross-contamination between samples. The sampler assumed that materials in ... Accessible spaces were inspected
Page 32: COMPREHENSIVE ASBESTOS INSPECTION 3180 F ROAD GRAND ... · potential for cross-contamination between samples. The sampler assumed that materials in ... Accessible spaces were inspected
Page 33: COMPREHENSIVE ASBESTOS INSPECTION 3180 F ROAD GRAND ... · potential for cross-contamination between samples. The sampler assumed that materials in ... Accessible spaces were inspected

May 7, 2018