COMPONENTS REQUIRED

21
COMPONENTS REQUIRED STEP DOWN PRANSFORMER: Ac applied to primary winding can be stepped down depending upon value of dc needed In our project 230v ac appear as 15v ac across secondary winding

description

COMPONENTS REQUIRED. STEP DOWN PRANSFORMER: Ac applied to primary winding can be stepped down depending upon value of dc needed In our project 230v ac appear as 15v ac across secondary winding. Excitation Power Source. - PowerPoint PPT Presentation

Transcript of COMPONENTS REQUIRED

Page 1: COMPONENTS REQUIRED

COMPONENTS REQUIRED

• STEP DOWN PRANSFORMER: Ac applied to primary winding can be stepped

down depending upon value of dc needed In our project 230v ac appear as 15v ac across secondary winding

Page 2: COMPONENTS REQUIRED

POWER SUPPLY UNIT

BLOCK DIAGRAM : +5 Volts +12 Volts -12 Volts

Step Down Transformer

Bridge Rectifier

Positive Charge Capacitor

Positive Voltage Regulator IC 7812

Negative Charge Capacitor

LPF

Negative Voltage Regulator IC 7912

LPF

+5V Regulator LPF

Page 3: COMPONENTS REQUIRED

PassiveTransducer

Excitation Power Source

+-

+-

0 to 100 % of physical impact

Output will be 0 if the Excitation is maximum for 0 to 100 % impact

Page 4: COMPONENTS REQUIRED

Signal Conditioner To ADC10

Ω

+4 - 20 m A -

Page 5: COMPONENTS REQUIRED

RECTIFIER UNIT

• Op-amp rectifier are used to convert ac to dc(IC LM 1458)CHARACTERISTICS OF OP-AMP It must be tunable It should not load pt and ct It should not have any conduction losses

Page 6: COMPONENTS REQUIRED

RELAYS

• Main function of relay is to detect the fault and intiate the operation of circuit breaker

ELECTROMAGNETIC RELAYS These relays acts as a switches which provides contact between two mechanical element

Page 7: COMPONENTS REQUIRED

INSTRUMENT TRANSFORMER

• CURRENT TRANSFORMER They are used so that ammeter and currents coils of instruments and relays need not be connected directly to high voltage line

Page 8: COMPONENTS REQUIRED

INSTRUMENT TRANSFORMER

• POTENTIAL TRANSFORMER High alternating voltage are reduced in a fixed proportion for the measurement purpose with help of potential transformer

Page 9: COMPONENTS REQUIRED

FILTERING UNIT

• It consists of capacitor acting as surge arrester

• To by pass ripples and high frequency signals

• It allows only low frequency signals

Page 10: COMPONENTS REQUIRED

VOLTAGE REGULATOR

• It helps rectifier and filter circuit in providing a constant dc voltage to device

Page 11: COMPONENTS REQUIRED

FIVE MODULES OF SCADA

• DATA ACQUIRING• DATA PROCESSING DATA CONVERSION• DATA MANIPULATION• DATA TRANSMISSION

Page 12: COMPONENTS REQUIRED

DATA ACQUIRING

• It acquires variable status like temperature pressure,flow etc components of data acquistion are from

simple thermocouple to complex gas analyser

Active transducer Passive transducer

Page 13: COMPONENTS REQUIRED

ACTIVE TRANSDUCER

• They are self generative as per physical variations offered to it

• ADVANTAGE Reliable low cost better inter changablity wide operating temperature

Page 14: COMPONENTS REQUIRED

PASSIVE TRANSDUCER

• These types of transducer have output will be full or partial of excitation

• ADVANTAGE available in all size DISADVANTAGE output will be reliable only if excitation source is reliable

Page 15: COMPONENTS REQUIRED

DATA ACQUIRING

• Flame detection• Intruder detection• Bomb detection• Cable fault detection• Staff attendance maintenance

Page 16: COMPONENTS REQUIRED

• FLAME DETECTION It can be used to detect fire in relays,

generator ,contacts with help of LDR INTRUDER DETECTION

Page 17: COMPONENTS REQUIRED

BOMB DETECTION

• SENSOR Inductive proximity sensor It can be used to detect even rdx bomb

Page 18: COMPONENTS REQUIRED

DATA PROCESSING

• It is much essential in field instrumentation for safe and secured operations of process industries

Page 19: COMPONENTS REQUIRED

DATA CONVERSION

• It is the process of converting analog into computing data

example of data converters are ADC and DAC

Page 20: COMPONENTS REQUIRED

DATA MANUPILATION

• It is the simple calculation between real value and ADC value

it comprises of • Recording of values • Graphical output• Indication • Controlling all application

Page 21: COMPONENTS REQUIRED

DATA TRANSMISSION

• It forms bridge between master control room and sub system area

• Radio frequency can be utilized for data communication