Top 10 Most Common Home Top 10 Most Common Home DefectsDefects

Presented byPresented by

National Association ofNational Association of

Certified Home InspectorsCertified Home InspectorsChicago ChapterChicago Chapter

Page 2: Commondefects

Copyright 2005 National Association of CertifieCopyright 2005 National Association of Certified Home Inspectorsd Home Inspectors

22

Top 10 Home DefectsTop 10 Home DefectsHere are examples of the top ten most common Here are examples of the top ten most common

defects found during home inspections. While defects found during home inspections. While common. Most of these defects can be easily, common. Most of these defects can be easily, and inexpensively, fixed.and inexpensively, fixed.

If left unattended to, these conditions can only get If left unattended to, these conditions can only get worse and lead to much more expensive repairs, worse and lead to much more expensive repairs, and in some cases, structural failure or fire.and in some cases, structural failure or fire.

Page 3: Commondefects

Copyright 2005 National Association of CertifieCopyright 2005 National Association of Certified Home Inspectorsd Home Inspectors

33

Top 10 Home DefectsTop 10 Home Defects1.1. Foundation: DrainageFoundation: Drainage

The house’s foundation should not be covered and The house’s foundation should not be covered and be visible for at least 6” for brick walls and at be visible for at least 6” for brick walls and at least 8” for siding and stucco walls.least 8” for siding and stucco walls.

Gutter downspouts should lead away from the Gutter downspouts should lead away from the foundation at least 6 feet, 10 feet is better.foundation at least 6 feet, 10 feet is better.

Covering the foundation can lead to water infiltration, Covering the foundation can lead to water infiltration, insect intrusion, rot, mold and structural failure. insect intrusion, rot, mold and structural failure.

Page 4: Commondefects

Copyright 2005 National Association of CertifieCopyright 2005 National Association of Certified Home Inspectorsd Home Inspectors

44

Top 10 Home DefectsTop 10 Home Defects1.1. FoundationFoundation

Page 5: Commondefects

Copyright 2005 National Association of CertifieCopyright 2005 National Association of Certified Home Inspectorsd Home Inspectors

55

Top 10 Home DefectsTop 10 Home Defects1.1. FoundationFoundation

Page 6: Commondefects

Copyright 2005 National Association of CertifieCopyright 2005 National Association of Certified Home Inspectorsd Home Inspectors

66

Top 10 Home DefectsTop 10 Home Defects1.1. FoundationFoundation

True Story:

Brand New 4,400 SF House

With A BIG Hidden Problem

Page 7: Commondefects

Copyright 2005 National Association of CertifieCopyright 2005 National Association of Certified Home Inspectorsd Home Inspectors

77

Top 10 Home DefectsTop 10 Home Defects1.1. FoundationFoundation

Nice brick planter at the front covers the foundations weep wicks with 3” of soil.

The result?

Page 8: Commondefects

Copyright 2005 National Association of CertifieCopyright 2005 National Association of Certified Home Inspectorsd Home Inspectors

88

Top 10 Home DefectsTop 10 Home Defects1.1. FoundationFoundation

Rotted Rim Joist and Sill Plate in 4 Months! $36,000 fix!

Page 9: Commondefects

Copyright 2005 National Association of CertifieCopyright 2005 National Association of Certified Home Inspectorsd Home Inspectors

99

Top 10 Home DefectsTop 10 Home Defects1.1. FoundationFoundation

Result – If Not Fixed.

Page 10: Commondefects

Copyright 2005 National Association of CertifieCopyright 2005 National Association of Certified Home Inspectorsd Home Inspectors

1010

Top 10 Home DefectsTop 10 Home Defects2.2. Electrical DefectsElectrical DefectsA house’s electrical system can cause the most A house’s electrical system can cause the most

dangerous problems if it is not properly and dangerous problems if it is not properly and professionally installed and maintained.professionally installed and maintained.

Always have any electrical work done by a licensed Always have any electrical work done by a licensed and insured electrical contractor.and insured electrical contractor.

Electricians in Illinois are Electricians in Illinois are notnot licensed by the state. licensed by the state. Some are ‘licensed’ by a municipality, requiring Some are ‘licensed’ by a municipality, requiring only minimum liability insurance.only minimum liability insurance.

Page 11: Commondefects

Copyright 2005 National Association of CertifieCopyright 2005 National Association of Certified Home Inspectorsd Home Inspectors

1111

Top 10 Home DefectsTop 10 Home Defects2.2. Electrical Panels – Location, InaccessibleElectrical Panels – Location, Inaccessible

Page 12: Commondefects

Copyright 2005 National Association of CertifieCopyright 2005 National Association of Certified Home Inspectorsd Home Inspectors

1212

Top 10 Home DefectsTop 10 Home Defects2.2. Electrical Panels – Owner RepairsElectrical Panels – Owner Repairs

Page 13: Commondefects

Copyright 2005 National Association of CertifieCopyright 2005 National Association of Certified Home Inspectorsd Home Inspectors

1313

Top 10 Home DefectsTop 10 Home Defects2.2. Electrical Panels – Double TappingElectrical Panels – Double Tapping

Page 14: Commondefects

Copyright 2005 National Association of CertifieCopyright 2005 National Association of Certified Home Inspectorsd Home Inspectors

1414

Top 10 Home DefectsTop 10 Home Defects2.2. Electrical Panels – Double Tapping MainElectrical Panels – Double Tapping Main

Page 15: Commondefects

Copyright 2005 National Association of CertifieCopyright 2005 National Association of Certified Home Inspectorsd Home Inspectors

1515

Top 10 Home DefectsTop 10 Home Defects2.2. Non-Professional / Homeowner WiringNon-Professional / Homeowner Wiring

Page 16: Commondefects

Copyright 2005 National Association of CertifieCopyright 2005 National Association of Certified Home Inspectorsd Home Inspectors

1616

Top 10 Home DefectsTop 10 Home Defects2.2. Electrical – Animal ProblemsElectrical – Animal Problems

Page 17: Commondefects

Copyright 2005 National Association of CertifieCopyright 2005 National Association of Certified Home Inspectorsd Home Inspectors

1717

Top 10 Home DefectsTop 10 Home Defects3.3. RoofRoofRoofing problems are common, and the most Roofing problems are common, and the most

easily dealt with. Make sure that all easily dealt with. Make sure that all roofing work is done professionally and roofing work is done professionally and properly.properly.

Roofers in Illinois are Roofers in Illinois are requiredrequired to be state to be state licensed and insured, but most are not.licensed and insured, but most are not.

Contractor E & O insurance guarantees the Contractor E & O insurance guarantees the quality of the work.quality of the work.

Page 18: Commondefects

Copyright 2005 National Association of CertifieCopyright 2005 National Association of Certified Home Inspectorsd Home Inspectors

1818

Top 10 Home DefectsTop 10 Home Defects3.3. Roof DrainageRoof Drainage

New House

Builder Saved $20.00.

Buyer Lost Roof in 2 Years!

All upper downspouts must drain to lower gutters.

Page 19: Commondefects

Copyright 2005 National Association of CertifieCopyright 2005 National Association of Certified Home Inspectorsd Home Inspectors

1919

Top 10 Home DefectsTop 10 Home Defects3.3. Roof DrainageRoof Drainage

12,000 SF House.

Downspout draining directly onto cedar shake roof.

Note the shake curling.

Page 20: Commondefects

Copyright 2005 National Association of CertifieCopyright 2005 National Association of Certified Home Inspectorsd Home Inspectors

2020

Top 10 Home DefectsTop 10 Home Defects3.3. Roof LeaksRoof Leaks

Quick Fix for Leaky Roof

Owner tries quick repair with elaborate siphon system.

Wound up ruining the bedroom ceiling because the bucket filled and broke through.

Page 21: Commondefects

Copyright 2005 National Association of CertifieCopyright 2005 National Association of Certified Home Inspectorsd Home Inspectors

2121

Top 10 Home DefectsTop 10 Home Defects3.3. Roof Deck Rot Due To MoistureRoof Deck Rot Due To Moisture

Lower gable attic, roof decking old, but serviceable

Upper gable attic, roof decking rotted and soft. Upper attic had un-vented bathroom exhaust fan.

Page 22: Commondefects

Copyright 2005 National Association of CertifieCopyright 2005 National Association of Certified Home Inspectorsd Home Inspectors

2222

Top 10 Home DefectsTop 10 Home Defects4.4. Heating Heating

Heating systems are most commonly Heating systems are most commonly plagued by the lack of the proper amount plagued by the lack of the proper amount of combustion air. Make sure that the of combustion air. Make sure that the furnace has an adequate source of furnace has an adequate source of combustion air. The rule is 10 cubic feet combustion air. The rule is 10 cubic feet of air for each cubic foot of gas burned.of air for each cubic foot of gas burned.

Without exterior venting, a 100,000 BTU Without exterior venting, a 100,000 BTU furnace requires a room 25 X 25 X 8 at a furnace requires a room 25 X 25 X 8 at a minimum!minimum!

Page 23: Commondefects

Copyright 2005 National Association of CertifieCopyright 2005 National Association of Certified Home Inspectorsd Home Inspectors

2323

Top 10 Home DefectsTop 10 Home Defects4.4. Heating - Insufficient Combustion AirHeating - Insufficient Combustion Air

Page 24: Commondefects

Copyright 2005 National Association of CertifieCopyright 2005 National Association of Certified Home Inspectorsd Home Inspectors

2424

Top 10 Home DefectsTop 10 Home Defects4.4. Heating - Insufficient Combustion AirHeating - Insufficient Combustion Air

Yellowing flame means carbon monoxide is being produced.

Beware of furnaces installed in closets that do not have an exterior air intake vent flue.

Page 25: Commondefects

Copyright 2005 National Association of CertifieCopyright 2005 National Association of Certified Home Inspectorsd Home Inspectors

2525

Top 10 Home DefectsTop 10 Home Defects4.4. Heating - Insufficient Combustion AirHeating - Insufficient Combustion Air

Failed heat exchanger caused by insufficient combustion air.

Page 26: Commondefects

Copyright 2005 National Association of CertifieCopyright 2005 National Association of Certified Home Inspectorsd Home Inspectors

2626

Top 10 Home DefectsTop 10 Home Defects4.4. Heating - Insufficient Combustion AirHeating - Insufficient Combustion Air

Brand new high efficiency furnace.

Improperly installed.

Note missing combustion air vent on left.

Page 27: Commondefects

Copyright 2005 National Association of CertifieCopyright 2005 National Association of Certified Home Inspectorsd Home Inspectors

2727

Top 10 Home DefectsTop 10 Home Defects5.5. Improper Maintenance and RepairImproper Maintenance and Repair

Always have all house repair done by Always have all house repair done by professional, licensed and insured professional, licensed and insured contractors.contractors.

Make sure that you are fully informed when Make sure that you are fully informed when you make any do-it-yourself repairsyou make any do-it-yourself repairs

Most times, money you think that you are Most times, money you think that you are saving, up front, is eaten up later.saving, up front, is eaten up later.

Page 28: Commondefects

Copyright 2005 National Association of CertifieCopyright 2005 National Association of Certified Home Inspectorsd Home Inspectors

2828

Top 10 Home DefectsTop 10 Home Defects5.5. Improper Maintenance – Owner RepairImproper Maintenance – Owner Repair

Leaky sink drain?

What to do?

The Old Diaper Trick.

Page 29: Commondefects

Copyright 2005 National Association of CertifieCopyright 2005 National Association of Certified Home Inspectorsd Home Inspectors

2929

Top 10 Home DefectsTop 10 Home Defects5.5. Improper Maintenance – Bad PlumbingImproper Maintenance – Bad Plumbing

Page 30: Commondefects

Copyright 2005 National Association of CertifieCopyright 2005 National Association of Certified Home Inspectorsd Home Inspectors

3030

Top 10 Home DefectsTop 10 Home Defects5.5. Non-Professional RepairsNon-Professional Repairs

No grounding.

Wires not enclosed, not waterproof.

Sink electrified!

Page 31: Commondefects

Copyright 2005 National Association of CertifieCopyright 2005 National Association of Certified Home Inspectorsd Home Inspectors

3131

Top 10 Home DefectsTop 10 Home Defects5.5. HVAC –Owner “Innovations”HVAC –Owner “Innovations”

New and “improved”, supercharged water heater.

The only smart thing about this setup is the fire extinguisher.

Page 32: Commondefects

Copyright 2005 National Association of CertifieCopyright 2005 National Association of Certified Home Inspectorsd Home Inspectors

3232

Top 10 Home DefectsTop 10 Home Defects6.6. Structural DamageStructural Damage

Structural damage is probably the most expensive type of damage to repair. If not done properly, your house can collapse.Structural damage is probably the most expensive type of damage to repair. If not done properly, your house can collapse.

Structural problems, though rare, are usually very expensive to repair.Structural problems, though rare, are usually very expensive to repair.

Page 33: Commondefects

Copyright 2005 National Association of CertifieCopyright 2005 National Association of Certified Home Inspectorsd Home Inspectors

3333

Top 10 Home DefectsTop 10 Home Defects6.6. Structural DamageStructural Damage

Floor joist cut to allow for heating duct. Structural integrity of the floor in danger.

Page 34: Commondefects

Copyright 2005 National Association of CertifieCopyright 2005 National Association of Certified Home Inspectorsd Home Inspectors

3434

Top 10 Home DefectsTop 10 Home Defects6.6. Structural DamageStructural Damage

Welding torch hole cut in steel beam in garage to facilitate the garage door opener.

Page 35: Commondefects

Copyright 2005 National Association of CertifieCopyright 2005 National Association of Certified Home Inspectorsd Home Inspectors

3535

Top 10 Home DefectsTop 10 Home Defects6.6. Structural DamageStructural Damage

1875 Apartment building.

Central foundation at the middle is failing.

Page 36: Commondefects

Copyright 2005 National Association of CertifieCopyright 2005 National Association of Certified Home Inspectorsd Home Inspectors

3636

Top 10 Home DefectsTop 10 Home Defects6.6. Structural DamageStructural Damage

Old pier with washed away footing and CMU blocks set on their sides.

Page 37: Commondefects

Copyright 2005 National Association of CertifieCopyright 2005 National Association of Certified Home Inspectorsd Home Inspectors

3737

Top 10 Home DefectsTop 10 Home Defects6.6. Structural DamageStructural Damage

Diagonal crack with multiple plane. Uneven settling, commonly seen in clay soil conditions.

A real structural problem.

Page 38: Commondefects

Copyright 2005 National Association of CertifieCopyright 2005 National Association of Certified Home Inspectorsd Home Inspectors

3838

Top 10 Home DefectsTop 10 Home Defects6.6. Structural DamageStructural Damage

Page 39: Commondefects

Copyright 2005 National Association of CertifieCopyright 2005 National Association of Certified Home Inspectorsd Home Inspectors

3939

Top 10 Home DefectsTop 10 Home Defects7.7. Plumbing ProblemsPlumbing Problems

Plumbing problems are most commonly Plumbing problems are most commonly caused by inadequate maintenance or caused by inadequate maintenance or owner repairs.owner repairs.

Plumbers, in Illinois, are Plumbers, in Illinois, are requiredrequired to be state to be state licensed and insured, but many are not.licensed and insured, but many are not.

Page 40: Commondefects

Copyright 2005 National Association of CertifieCopyright 2005 National Association of Certified Home Inspectorsd Home Inspectors

4040

Top 10 Home DefectsTop 10 Home Defects7.7. Plumbing Problems – Water HeaterPlumbing Problems – Water Heater

Page 41: Commondefects

Copyright 2005 National Association of CertifieCopyright 2005 National Association of Certified Home Inspectorsd Home Inspectors

4141

Top 10 Home DefectsTop 10 Home Defects7.7. Plumbing Problems – Improper Fixture UsePlumbing Problems – Improper Fixture Use

Page 42: Commondefects

Copyright 2005 National Association of CertifieCopyright 2005 National Association of Certified Home Inspectorsd Home Inspectors

4242

Top 10 Home DefectsTop 10 Home Defects8.8. Water and Air InfiltrationWater and Air Infiltration

Water infiltration is, often, the most easily avoided Water infiltration is, often, the most easily avoided house problem. Remember, to a house, water is house problem. Remember, to a house, water is the enemy.the enemy.

Water in wood = ROT, regardless of the age of the Water in wood = ROT, regardless of the age of the wood. A brand new 2 x 4 can completely rot in 4 wood. A brand new 2 x 4 can completely rot in 4 months if its moisture content is greater than 38%. months if its moisture content is greater than 38%. Kiln dried wood has a moisture content < 4%. Kiln dried wood has a moisture content < 4%.

Page 43: Commondefects

Copyright 2005 National Association of CertifieCopyright 2005 National Association of Certified Home Inspectorsd Home Inspectors

4343

Top 10 Home DefectsTop 10 Home Defects8.8. Water and Air InfiltrationWater and Air Infiltration

Page 44: Commondefects

Copyright 2005 National Association of CertifieCopyright 2005 National Association of Certified Home Inspectorsd Home Inspectors

4444

Top 10 Home DefectsTop 10 Home Defects8.8. Water and Air InfiltrationWater and Air Infiltration

Thermal imaging to display ceiling water infiltration.

Page 45: Commondefects

Copyright 2005 National Association of CertifieCopyright 2005 National Association of Certified Home Inspectorsd Home Inspectors

4545

Top 10 Home DefectsTop 10 Home Defects8.8. Water and Air InfiltrationWater and Air Infiltration

Page 46: Commondefects

Copyright 2005 National Association of CertifieCopyright 2005 National Association of Certified Home Inspectorsd Home Inspectors

4646

Top 10 Home DefectsTop 10 Home Defects9.9. Crawlspace / Attic VentilationCrawlspace / Attic Ventilation

Along guarding against water infiltration, Along guarding against water infiltration, proper ventilation is the best way to make proper ventilation is the best way to make sure that water is kept out.sure that water is kept out.

Crawlspaces and attics Crawlspaces and attics mustmust be ventilated in be ventilated in order to avoid wood rot and mold.order to avoid wood rot and mold.

Page 47: Commondefects

Copyright 2005 National Association of CertifieCopyright 2005 National Association of Certified Home Inspectorsd Home Inspectors

4747

Top 10 Home DefectsTop 10 Home Defects9.9. Crawlspace / Attic VentilationCrawlspace / Attic Ventilation

Page 48: Commondefects

Copyright 2005 National Association of CertifieCopyright 2005 National Association of Certified Home Inspectorsd Home Inspectors

4848

Top 10 Home DefectsTop 10 Home Defects9.9. Crawlspace / Attic VentilationCrawlspace / Attic Ventilation

Clothes dryer vented to Attic

6 month old house

Rotten roof decking

Page 49: Commondefects

Copyright 2005 National Association of CertifieCopyright 2005 National Association of Certified Home Inspectorsd Home Inspectors

4949

Top 10 Home DefectsTop 10 Home Defects9.9. Crawlspace / Attic VentilationCrawlspace / Attic Ventilation

Bathroom Exhaust Fan Vented to Attic

Page 50: Commondefects

Copyright 2005 National Association of CertifieCopyright 2005 National Association of Certified Home Inspectorsd Home Inspectors

5050

Top 10 Home DefectsTop 10 Home Defects9.9. Crawlspace / Attic VentilationCrawlspace / Attic Ventilation

Page 51: Commondefects

Copyright 2005 National Association of CertifieCopyright 2005 National Association of Certified Home Inspectorsd Home Inspectors

5151

Top 10 Home DefectsTop 10 Home Defects9.9. Crawlspace / Attic VentilationCrawlspace / Attic VentilationWeird things found in attics and crawlspaces

Page 52: Commondefects

Copyright 2005 National Association of CertifieCopyright 2005 National Association of Certified Home Inspectorsd Home Inspectors

5252

Top 10 Home DefectsTop 10 Home Defects9.9. Crawlspace / Attic VentilationCrawlspace / Attic VentilationWeird things found in attics and crawlspaces

Page 53: Commondefects

Copyright 2005 National Association of CertifieCopyright 2005 National Association of Certified Home Inspectorsd Home Inspectors

5353

Top 10 Home DefectsTop 10 Home Defects9.9. Crawlspace / Attic VentilationCrawlspace / Attic Ventilation

The deadly “Assassin Kitty”!

Page 54: Commondefects

Copyright 2005 National Association of CertifieCopyright 2005 National Association of Certified Home Inspectorsd Home Inspectors

5454

Top 10 Home DefectsTop 10 Home Defects10.10. Non-Inspected Construction DefectsNon-Inspected Construction Defects

Just because your house passed a Just because your house passed a governmental code inspection, that is no governmental code inspection, that is no guarantee that it is free of defects. Code guarantee that it is free of defects. Code inspectors are overworked and building inspectors are overworked and building codes are merely codes are merely minimalminimal requirements. requirements.

Even brand new houses can have substantial Even brand new houses can have substantial and expensive defects and safety and expensive defects and safety hazards!hazards!

Page 55: Commondefects

Copyright 2005 National Association of CertifieCopyright 2005 National Association of Certified Home Inspectorsd Home Inspectors

5555

Top 10 Home DefectsTop 10 Home Defects10.10. Non-Inspected Construction DefectsNon-Inspected Construction Defects

Page 56: Commondefects

Copyright 2005 National Association of CertifieCopyright 2005 National Association of Certified Home Inspectorsd Home Inspectors

5656

Top 10 Home DefectsTop 10 Home Defects10.10. Non-Inspected Construction DefectsNon-Inspected Construction Defects

Page 57: Commondefects

Copyright 2005 National Association of CertifieCopyright 2005 National Association of Certified Home Inspectorsd Home Inspectors

5757

Top 10 Home DefectsTop 10 Home Defects10.10. Non-Inspected Construction DefectsNon-Inspected Construction Defects

Page 58: Commondefects

Copyright 2005 National Association of CertifieCopyright 2005 National Association of Certified Home Inspectorsd Home Inspectors

5858

Top 10 Home DefectsTop 10 Home Defects10.10. Installation DefectsInstallation Defects

Hair dryer installed near bathroom basin, against manufacturer’s instructions.

Page 59: Commondefects

Copyright 2005 National Association of CertifieCopyright 2005 National Association of Certified Home Inspectorsd Home Inspectors

5959

Top 10 Home DefectsTop 10 Home Defects10.10. Old / Defected Electrical EquipmentOld / Defected Electrical Equipment

Federal Pacific Equipment

Zinsco

Page 60: Commondefects

Copyright 2005 National Association of CertifieCopyright 2005 National Association of Certified Home Inspectorsd Home Inspectors

6060

Thank you for your time.Thank you for your time.

Questions?Questions?

Top 10 Home DefectsTop 10 Home Defects