Commissioning and Integration Flexi Multi Radio

79
1 © Nokia Siemens Networks BSC S14 IFI / 090409 For internal use Flexi Multiradio BTS Commissioning and Integration

Transcript of Commissioning and Integration Flexi Multi Radio

Page 1: Commissioning and Integration Flexi Multi Radio

1 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Flexi Multiradio BTS Commissioning and Integration

Page 2: Commissioning and Integration Flexi Multi Radio

2 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

ContentPreparing for Commissioning

2G Flexi BTS Manager

Commissioning Types

Creating SCF File (Offline)

Local Commissioning

Demonstration

Page 3: Commissioning and Integration Flexi Multi Radio

3 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Preparing for Commissioning

Page 4: Commissioning and Integration Flexi Multi Radio

4 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Preparing for CommissioningCommissioning Prerequisite (1/2)

• Before commissioning, the physical installation of the BTS (modules, cabling, antennas and radios) must be completed.

• Make sure a PC with 2G Flexi BTS Site Manager installed.• One 10/100 Mbit/s Ethernet cable needed for the

connection between the BTS and user PC.• Parameter values must be available to be entered during

commissioning. The parameter values are provided by the network planning process.

• BSC settings: the BTS site must already be created at the BSC for commissioning to be successfully completed.

Page 5: Commissioning and Integration Flexi Multi Radio

5 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Preparing for CommissioningCommissioning Prerequisites (2/2)

• Transmission network setup: the transmission link(s) between the BSC and the BTS must already be set up so that there is a transmission path from the BSC to the BTS for all the Abis channels.

• If there are any intermediate transmission hubs between the BSC and the BTS, the cross connections in the hubs should either be set up at the E1/T1 link level, or at the n x 64 kbit/s level for all the channels to the BTS in an E1/T1 link.

• With the Flexi transmission interface Flexbus sub-module (FIFA), the transmission link will be established during commissioning.

Screenshots included are representations and should be considered as examples only. The current release of the 2G Flexi BTS Site Manager software may differ slightly from the shots depicted

Page 6: Commissioning and Integration Flexi Multi Radio

6 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Preparing for CommissioningVisual Check Inspections• Perform the first part of the visual check before powering on the BTS at the

power system. • Check the equipment visually to see that there are no fatal installation errors,

which might lead to equipment damage during the power on, such as– the grounding– power cabling and supply voltage– other cables and fibres– LED status during power up– TX/RX/antenna connector torque check– Flexbus cables (used with FIFA)– LAN cable (used with the E1 transmission card)– LAN cables (used for TDM or Fast Ethernet transmission with FIPA, FIEA, FIQA,

FIYA)– Optical fibres (used for Gigabit Ethernet transmission with FIQA, FIYA)

• When all is proven to be OK, perform the 'Power on' check and verify the LED status.

Page 7: Commissioning and Integration Flexi Multi Radio

7 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Preparing for CommissioningInstalling the 2G Flexi BTS Site Manager (1/4)

• Software needed in order to do commissioning/ supervising the Flexi Mutiradio is 2G Flexi BTS Site Manager (mandatory) and Flexi Hub manager (if FIFA is used).

• Both Software can be downloaded via NOLS.

• Please ensure that both manager software must be compatible with the software level installed in the BTS.

• User can check the compatibility at Software compatibility of Flexi Multiradio BTS document in NED.

Page 8: Commissioning and Integration Flexi Multi Radio

8 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Preparing for CommissioningInstalling the 2G Flexi BTS Site Manager (2/4)

• Check the system requirement of the PC before install the site manager

Page 9: Commissioning and Integration Flexi Multi Radio

9 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Preparing for CommissioningInstalling the 2G Flexi BTS Site Manager (3/4)

• Install the 2G Flexi BTS Manager and follow the instruction on the installing wizard.

• On successful completion of installation shortcuts will be created on your desktop and in the Start menu to launch the 2G Flexi BTS Site Manager.

Page 10: Commissioning and Integration Flexi Multi Radio

10 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Preparing for CommissioningInstalling the 2G Flexi BTS Site Manager (4/4)

• On successful completion of installation shortcuts will be created on your desktop and in the Start menu to launch the 2G Flexi BTS Site Manager.

Note:1.On certain computers, you may also be required to restart your computer before running the application.2. Re-installing the same version of the product will over-write the previous configuration with the default settings.

Page 11: Commissioning and Integration Flexi Multi Radio

11 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

2G Flexi BTS Manager

Page 12: Commissioning and Integration Flexi Multi Radio

12 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

2G Flexi BTS ManagerMain window

• To launch the 2G Flexi BTS Manager user can click shortcuts in the Start Menu, and following window will come up.

For commissioning/ supervison if PC connect dircctly to BTS

For re-commissioning/ supervison if PC connect BTS via NetAct (remotely)

For creating the SCF or EasyWizard Template if PC connect BTS offline (PC not connected to BTS)

For help

List of release package and 2G Flexi BTS Site Manager versions

List of release package and 2G Flexi BTS Site Manager versions

Page 13: Commissioning and Integration Flexi Multi Radio

13 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

2G Flexi BTS ManagerMain window – Local Connection

• By clicking the Local connection option, then come this following window

IP Address of ESMB/C

As defult: no password, just left this box blank

For detail see comissioning process part

Page 14: Commissioning and Integration Flexi Multi Radio

14 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

2G Flexi BTS ManagerMain window – Local Connection

• By clicking the Remote connection option, then come this following window:

Mandatory to fill

Page 15: Commissioning and Integration Flexi Multi Radio

15 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

2G Flexi BTS ManagerMain window – Local Connection

• By clicking the Create File option, then come this following window:

Release packages and 2G Flexi BTS

Site Manager versions

For detail see Creating SCF file offline

Page 16: Commissioning and Integration Flexi Multi Radio

16 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

2G Flexi BTS ManagerMain window – Local Connection

• By clicking the Tool option, then come this following window:

Available tools (help for BTS Site Manager)

Page 17: Commissioning and Integration Flexi Multi Radio

17 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

2G Flexi BTS ManagerMain window – Local Connection

• By clicking the Tool option, then come this following window:

List of installed Release packages and 2G Flexi BTS Site manager version

Page 18: Commissioning and Integration Flexi Multi Radio

18 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Commissioning Types

Page 19: Commissioning and Integration Flexi Multi Radio

19 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Commissioning typesCommissioning Process Goal (1/2)

• The commissioning process is divided into 4 different commissioning processes depending on the connection and commissioning statuses:

– BTS is not connected: The user intends to create SCF file or an EasyWizard template.

– BTS is connected and uncommissioned: The user wants to bring up the BTS in functional state. He can either use an EasyWizard like template or can specify the settings manually

– BTS is connected and commissioned:  The user wants to upgrade the configuration or can change the configuration. This may either simply append in existing configuration or may lead to recommissioning of BTS based on the new settings to be upgraded or changed.

– BTS is connected remotely and commissioned:  The user wants to upgrade the configuration or can change the configuration. This may either simply append in existing configuration or may lead to recommissioning of BTS based on the new settings to be upgraded or changed.

Page 20: Commissioning and Integration Flexi Multi Radio

20 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Commissioning typesCommissioning Process Goal (2/2)• The possible ways to perform commissioning process are:

– Use existing SCF (Site Configuration File)– Upload SCF from BTS – Create SCF by manual commissioning using Commissioning Wizard

• Note: User should not modify the Site Configuration File by using XML editor. Only the BTS Manager should be used to change any values in SCF.

• The Commissioning Wizard will guide user through configuration. By clicking "next" button the wizard will continue to the next configuration screen

• The wizard consist following screen:– Site specific Information– Hardware Configuration– Transmission Parameter

Page 21: Commissioning and Integration Flexi Multi Radio

21 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Commissioning TypesBTS is not connected

Page 22: Commissioning and Integration Flexi Multi Radio

22 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Commissioning TypesBTS connected-uncommissioned

Page 23: Commissioning and Integration Flexi Multi Radio

23 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Commissioning Types BTS connected-commissioned

Page 24: Commissioning and Integration Flexi Multi Radio

24 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Commissioning Types BTS connected remotely-commissioned

Page 25: Commissioning and Integration Flexi Multi Radio

25 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Creating SCF File (Offline)

Page 26: Commissioning and Integration Flexi Multi Radio

26 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Creating SCF File (Offline)Select Create File from main window• If the BTS is not connected the user intends to create SCF file or an

EasyWizard template. • From the 2G Flexi BTS Site Manager main window choose Create File select

packages and 2G Flexi BTS Site Manager versions in the dropdown menu click “create” button:

1

2

3

Page 27: Commissioning and Integration Flexi Multi Radio

27 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Creating SCF File (Offline)Commissioning menu

Page 28: Commissioning and Integration Flexi Multi Radio

28 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Creating SCF File (Offline)Create EasyWizard Hardware & Transmission template

The file created will be with extension .epb

The file created will be with extension .ept

Page 29: Commissioning and Integration Flexi Multi Radio

29 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Creating SCF File (Offline)Create SCF (Complete SCF) The file created will

be with extension .xml

The file created will be with

extension .xml

Page 30: Commissioning and Integration Flexi Multi Radio

30 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local Commissioning

Page 31: Commissioning and Integration Flexi Multi Radio

31 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local CommissioningIP Setup for Local Commissioning PC

• Connect via LMP on ESMx using ethernet cable• Setup the local IP address on PC under Internet

Protocol (TCP/IP) properties as follow:IP address: 192.168.255.130Subnet Mask: 255.255.255.128Default Gateway: none

• Personal Firewall may need to allow access to local network

eg ZoneAlarm• The default settings of the BTS are: IP address: 192.168.255.1312G Flexi BTS Site Manager connection TCP Port:

27500• 2G Flexi BTS Site Manager SW download via TCP

Port: 27501

Page 32: Commissioning and Integration Flexi Multi Radio

32 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local Commissioning Flexi 2G BTS Site Manager (1/2)

• Nokia Siemens Networks 2G Flexi BTS Site Manager allows the BTS operators to

– Commission – Configure – Monitor the BTS

• These tasks are performed with option:– at the BTS site (known as Local

Connection) – via communication from the NMS

system.– BSC site (known as Remote

Connection). • 2G Flexi BTS Site Manager is for

maintaining and commissioning Flexi Multiradio base transceiver stations.

Page 33: Commissioning and Integration Flexi Multi Radio

33 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local Commissioning Flexi 2G BTS Site Manager (2/2)

Local Connection directly to Flexi Multiradio BTS

GSM/EDGE

Remote Connection via NetAct

Create file (commissioning file

IP address of System Module, and Password

just keep empty

Create File is to create the template or SCF

Page 34: Commissioning and Integration Flexi Multi Radio

34 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local CommissioningLocal Connection

Page 35: Commissioning and Integration Flexi Multi Radio

35 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local Commissioning Flexi 2G BTS Site Manager window

The main functions of Flexi BTS manager are: • BTS

commissioning• BTS supervision• BTS maintenance• BTS testing

In main menu, the view are:• Alarms• Base Station• Commissioning• Supervision• Transmission• Tests

Navigation bar

Logical BTS view

Properties

Alarms view

Connection feeedback

Page 36: Commissioning and Integration Flexi Multi Radio

36 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local CommissioningCommissioning Wizard

Select the Commissioning → Wizard menu item or click the Commissioningbutton on the View Selection Bar.

Page 37: Commissioning and Integration Flexi Multi Radio

37 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local CommissioningUndo Commissioning (1/4)

• to revert the site to un-commissioned mode and he can also check the option that whether user wants to erase bypass capacity along with it or no.

• This button is disabled in remote connection

Page 38: Commissioning and Integration Flexi Multi Radio

38 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local CommissioningUndo Commissioning (2/4)

Page 39: Commissioning and Integration Flexi Multi Radio

39 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local CommissioningUndo Commissioning (3/4)

Indicate the BTS has successfully uncommissioned

Page 40: Commissioning and Integration Flexi Multi Radio

40 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local Commissioning Undo Commissioning (4/4)

• If the BTS is in un-commissioned mode, the connecting RF module is not automatically detected

• Connecting RF module will be detected if the BTS has been commissioned

Page 41: Commissioning and Integration Flexi Multi Radio

41 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local Commissioning Commissioning Manually

• In this example, user do commissining manually

Page 42: Commissioning and Integration Flexi Multi Radio

42 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local Commissioning Commissioning Manually - Procedure

• Site Specific Information

• Hardware Configuration

• Module Configuration• Local Sector Settings• Antenna Settings

• RET Setting• FRM EAC Settings• Battery Backup Unit• Other Passive Units

• Transmission parameter

• Physical Setting• LIF Settings• Synchronization• Abis Termination

• Abis Allocation• Abis Protection

• Cross Connection• Q1 Management

Page 43: Commissioning and Integration Flexi Multi Radio

43 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Navigation tree - Enables

user to navigate any screen, and update/view parameters

corresponding to that screen.

Data persistence is

maintained across screen navigations

Local Commissioning Site Specific Information

Navigation tree - Enables

user to navigate any screen, and update/view parameters

corresponding to that screen.

Data persistence is

maintained across screen navigations

Page 44: Commissioning and Integration Flexi Multi Radio

44 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local Commissioning Hardware Configuration

• If user has hardware template file (.epb or SCF file), specify from file can be selected

• In this example specify manually is selected

Page 45: Commissioning and Integration Flexi Multi Radio

45 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local Commissioning Hardware Configuration – Module Configuration

configure various radio modules, synchronization master, and radio masters

Page 46: Commissioning and Integration Flexi Multi Radio

46 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local CommissioningHardware Configuration – Local Sector setting

configure and associate antennas of only one type of RF unit (RM) to a particular local sector and specify per TRX power

Page 47: Commissioning and Integration Flexi Multi Radio

47 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local Commissioning Hardware Configuration – Antenna Settings

Select the antenna line settings, specify MHA settings, provide information for feeder voltage, feeder loss, VSWR minor and major limits for the selected antenna

Page 48: Commissioning and Integration Flexi Multi Radio

48 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

User can change the Received Signal Strength Indicator (RSSI) sample count

Local Commissioning Hardware Configuration – Antenna monitoring parameters

Page 49: Commissioning and Integration Flexi Multi Radio

49 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

configuration of RETs in either online or offline mode

Local Commissioning Hardware Configuration – RET settings

Page 50: Commissioning and Integration Flexi Multi Radio

50 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local Commissioning Hardware Configuration – RFM EAC settings

configure the external alarm lines associated with the individual FRMs

Page 51: Commissioning and Integration Flexi Multi Radio

51 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local CommissioningHardware Configuration – Battery Backup Unit

Enter the battery backup unit parameters

Page 52: Commissioning and Integration Flexi Multi Radio

52 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local CommissioningHardware Configuration – Passive Units

Enter the passive unit parameters

Page 53: Commissioning and Integration Flexi Multi Radio

53 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local CommissioningTransmission Parameter

• If user has transmission template file (.ept or SCF file), specify from file can be selected

• Upload from BTS used if user want to oads the transmission configuration from the BTS and which can then be edited by the user, if required

• In this example specify manually is selected

Page 54: Commissioning and Integration Flexi Multi Radio

54 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local CommissioningTransmission Parameter – Physical settings

• Setting the functionality of interface (E1 or T1)

Page 55: Commissioning and Integration Flexi Multi Radio

55 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local Commissioning Transmission Parameter – LIF Setting

• Setting the use interface settings, modify the CRC (if required) and name of the interface

Page 56: Commissioning and Integration Flexi Multi Radio

56 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local CommissioningTransmission Parameter – Synchronization (Source)

• Select the E1 for synchronizaton reference and modify the priority of the reference synchronization among defined E1

Page 57: Commissioning and Integration Flexi Multi Radio

57 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local CommissioningTransmission Parameter – Synchronization (Protection)

• Define the topology (default is Chain)

• user can define the synchronization protection if the topology is Loop

Page 58: Commissioning and Integration Flexi Multi Radio

58 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local CommissioningTransmission Parameter – Synchronization (Output)

user can enable or disable the 2MHz clock output from one BTS, to be used as the synchronization source for any other connected BTS.

Page 59: Commissioning and Integration Flexi Multi Radio

59 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local Commissioning Transmission Parameter – Abis Termination

• In Satellite Abis, specify if there is a satellite circuit in the link between the BTS and the BSC

• Enable Abis Signal Mapping allows the BSC to dynamically provide the Abis allocations (TRXSIG, TCH, EDAP) for a BTS

• If Allow Abis Allocations from BTS Manager is thicked (enabled), user can allocate the Abis allocations from the BTS Manager but these allocations can be overridden by the BSC

Page 60: Commissioning and Integration Flexi Multi Radio

60 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local Commissioning Transmission Parameter – Abis Allocation

• Enter the Abis Allocation parameters (OMUSIG, TRXSIG, TCH and EDAP)

• If Enable Abis Signal Mapping is chosen, only OMUSIG can be specified, the rest will be mapping by the BSC

• If Enable Abis Signal Mapping is chosen and Allow Abis Allocations from BTS Manager is thicked , all signaling can be allocated in Abis, but these allocations can be overridden by the BSC

Page 61: Commissioning and Integration Flexi Multi Radio

61 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local CommissioningTransmission Parameter – Abis Protection

• If Loop topology is used, Abis protection can be defined

Page 62: Commissioning and Integration Flexi Multi Radio

62 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local CommissioningTransmission Parameter – Cross Connection

Page 63: Commissioning and Integration Flexi Multi Radio

63 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local CommissioningCross Connection – Q1 Management

Page 64: Commissioning and Integration Flexi Multi Radio

64 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local CommissioningFlexhub

•User need to install the FlexiHub Manager beforehand

Page 65: Commissioning and Integration Flexi Multi Radio

65 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local CommissioningSCF preview - Summary

• From this summary, user can check whether the commissioing step has been completed.

• This can be checked by looking at the indication color of each step, green means ok, red means not complete

Page 66: Commissioning and Integration Flexi Multi Radio

66 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local Commissioning SCF preview - Detail

Page 67: Commissioning and Integration Flexi Multi Radio

67 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local CommissioningViewing the commissioning progress and the commissioningresult

Page 68: Commissioning and Integration Flexi Multi Radio

68 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local CommissioningCommissioning completeted

Page 69: Commissioning and Integration Flexi Multi Radio

69 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local Commissioning Commissioning Report

Executive Summary

Detail Report

Old

est

Page 70: Commissioning and Integration Flexi Multi Radio

70 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local CommissioningExample if the TRX test is failed

Page 71: Commissioning and Integration Flexi Multi Radio

71 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local Commissioning BCF Object after commissioning

Page 72: Commissioning and Integration Flexi Multi Radio

72 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local Commissioning Cell Object after commissioning

Page 73: Commissioning and Integration Flexi Multi Radio

73 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local Commissioning TRX Object after commissioning

Page 74: Commissioning and Integration Flexi Multi Radio

74 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local Commissioning Tracing the traffic during the test call

• From the toolbar select Test menu select Traffic trace select cell would be traced --> click Automatic Update (if necessary)

• For the CS call, yellow color indicates the RTSL that being occupied

Page 75: Commissioning and Integration Flexi Multi Radio

75 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local Commissioning Fetch SCF from BTS

• From the toolbar select Commissioningmenu select Fetch SCF from BTS Save the SCF file (.xml) in local PC

Page 76: Commissioning and Integration Flexi Multi Radio

76 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local Commissioning Fetch the commissioning report

• From the toolbar select Commissioning menu select Report select Fetch from BTS Save the Commissioning Report in Local PC

Page 77: Commissioning and Integration Flexi Multi Radio

77 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local Commissioning Site Information

•From the toolbar select Supervision menu select Site Information Save the Site Information file in Local PC

Page 78: Commissioning and Integration Flexi Multi Radio

78 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use

Local Commissioning Check on the BSC (1/2) • Using MML command: ZEEI: <bcf_id>; user can check the status of BTS

object under specific BCF.

OADING PROGRAM VERSION 22.4-1BSC LINDA 2010-05-10 16:38:19RADIO NETWORK CONFIGURATION IN BSC: E P B F T R C D-CHANNEL BUSY AD OP R ET- BCCH/CBCH/ R E S O&M LINK HR FR LAC CI HOP ST STATE FREQ T PCM ERACH X F U NAME ST /GP===================== == ====== ==== == ==== =========== = = == ===== == === ===

BCF-0051 FLEXI MULTIRADIO U WO 0 OM051 WO 00220 22010 BTS-0010 U WO 0 2 DEMOBTS1 -/- 6 TRX-001 U WO 12 0 51 MBCCHC P 0 TRX-002 U WO 20 0 51 0 TRX-003 U WO 30 0 47 3 TRX-004 U WO 40 0 47 3 00220 22011 BTS-0011 U WO 0 2 DEMOBTS2 -/- 6 TRX-005 U WO 50 0 51 MBCCHC P 1 TRX-006 U WO 60 0 51 1 TRX-007 U WO 70 0 47 3 TRX-008 U WO 80 0 47 3 00220 22012 BTS-0012 U WO 0 2 DEMOBTS3 -/- 1 TRX-009 U WO 90 0 51 MBCCHC P 1 TRX-010 U WO 100 0 51 1 TRX-011 U WO 110 0 47 3 TRX-012 U WO 120 0 47 3

Page 79: Commissioning and Integration Flexi Multi Radio

80 © Nokia Siemens Networks BSC S14 IFI / 090409For internal use