Commercial & Domestic - Compu Pool Products Owners Manual... · Salt Water Chlorine Generator By...
Transcript of Commercial & Domestic - Compu Pool Products Owners Manual... · Salt Water Chlorine Generator By...
Salt Water Chlorine GeneratorBy Compu Pool Products
In-ground Model
Commercial & Domestic
CPSC/CPA SERIES
Head Office 88 Spencer Rd. Nerang,
Gold Coast Australia
P: +61(07) 5596 3773 F: +61(07) 5596 1951 E: [email protected] W: www.compupool.com.au
• Allfieldmetalcomponentssuchasrails,ladders,drains,orother similarhardwarewithin10feetoffthepoolorspashallbe bondedtotheequipmentgroundingbuswithcopper conductorsnotsmallerthan8AWGUS/6AWGCanada.
• FollowallaspectsofthelocalandNationalElectricalCode(s) wheninstallingCompu-Pool,modelCPSC/CPASeries.
• Note:Foroutdoorpools,chlorineresidualscanbeprotected fromdestructionbysunlightbyadditionofstabilizer(cyanuricacid).
• Forpropersanitation,spasmustbecompletelydrained periodically.ThenumberofdaysbetweenCOMPLETESPA DRAINAGEisequaltothevolumeofspawateringallons, dividedby10timesthemaximumnumberofdailyspausers. RefillspawithwaterandrepeatDIRECTIONSFORUSEofthe device.
Health and Hyperthermia warnings for spa devices:
• Peoplewithamedicalconditionshouldconsultaphysician beforeenteringpoolorspawater.
• Maximumspawaterusagetemperatureis104°F.Bathinginspa waterat104°Fshouldnotexceed15minutes.
SAFETY INSTRUCTIONS:
Congratulationsonyour recentpurchaseofaCompu-PoolProductsSaltWaterChlorineGenerator.Pleasetakeamomenttoreadthroughtheentiremanualbeforeinstallingyournewunit.Yourgeneratormustbeinstalledandoperatedasspecified.
IMPORTANTSAFETYINSTRUCTIONS.READANDFOLLOWALLINSTRUCTIONS.SAVEALLINSTRUCTIONS.
• WARNING:Toreducetheriskofinjury,donotpermitchildrento operatethisdevice
• WARNING:Heavypool(and/orspa)usage,andhigher temperaturesmayrequirehigherchlorineoutputtomaintain properfreeavailablechlorineresiduals
• Ifadditionalchlorineisrequiredduetoheavybatherloads, use(sodiumhypochlorite)tomaintainanappropriatechlorine residualinthewater
• Maintaininghighsaltandchlorinelevelsaboverecommended rangecancontributetocorrosionofpool(and/orspa)equipment.
• Thelifeoftheelectrolyticcellis12,500hours,undernormal use conditions
• DONOTaddpool(and/orspa)chemicalsdirectlytotheskimmer. Thismanydamagethecell.
• Checktheexpirationdateofthetestkitastestresultsmaybe inaccurateifusedafterthatdate.
• Whenreplacingthecell,onlyusereplacementcellshaving alabelthatclearlystatesthatitisthereplacementcellforthe chlorinegeneratingdevice.
• Onebondinglugisprovidedontheexternalsurface.Toreduce theriskofelectricshock,connectthelocalcommonbonding gridintheareaoftheswimmingpoolorspatotheseterminals withaninsulatedorbarecopperconductornotsmallerthan 8AWGUS/6AWGCanada.
TABLE OF CONTENTS:
OPERATION p1
THE CHEMISTRY INVOLVED p1
MAINTENANCE p2
USING THE CONTROL PANEL p4
ADDING SALT p7
TypeofSalt p8
SaltLevelFormula p8
Winterizing p10
SaltTable p11
INSTALLATION p12
InstallingthePowerUnit p12
InstallingtheCell p12
Wiring p13
Input Power p13
Bonding p15
ElectrolyticCell p16
DismantlingtheCell p16
CleaningtheCell p16
InstallationCheckList p17
HelpfulHints p18
TroubleShooting p20
Warranty p22
COMPU-POOL CPSC/CPA Series OWNERS MANUAL
• I n - g r o u n d M o d e l •
OPERATION:
ThechlorinatorPowerUnit istobemountedatleast3feetaboveground level and if possible protected from direct weather. TheChlorinatorElectrolyticCellistobeplumbedinthereturntopoollineafterthepumpandfilter.Waterflowthroughthecellcanbeineitherdirectionandidealinstallationishorizontal.Thecellleadplugfromthepowerunitistobeconnectedtotheheadofthecell.
The unit has been designed to run off a salinity concentration of3500PPM.
THe CHeMISTrY InVolVed:
The CPSC/CPA Series chlorine generator, by electrolysis, producessodium hypochlorite (NaOCI). In water, sodium hypochloritedissociatesintosodium(Na+)andhypochlorite(OCI-)ions.
It is the hypochlorite ions that form with the hydrogen (H+) ions (fromthewater)toformhypochlorousacid(HOCI),theactiveagentthatdestroysbacteriaandalgae,andoxidizesorganicmatter.
1.
4. Chloramines:Chloraminesshouldnotbepresentinpoolwater.WhenorganicmaterialscombinewithFreeChlorine,Chloraminesareformed.ThistiesuptheFreechlorineinyourpoolanddoesnotallowthechlorine inyourpool todisinfect.Chloraminesalsocloudpoolwaterandburntheeyes.(SuperChlorinate(shock)toremoveChloraminesattheinitialstartupofthepool).
5. pH Levels:pHproducedbytheChlorinatorisclosetoNeutralpH.However,other factors usually cause the pH of the pool water to rise.Therefore,thepHinapoolchlorinatedbytheChlorinatortendstostabilizeatapproximately7.8.Thisiswithinnationalstandards.IfthepoolpHrisesabove7.8haveapoolprofessionaltesttoseeifotherfactorssuchashighCalciumHardnessorTotalAlkalinityarethecauseandthenbalanceaccordingly.
6. Total dissolved Solids (TdS):AddingsalttopoolwaterwillraisetheTDSlevel.Whilethisdoesnotadverselyaffectthepoolwaterchemistryorclarity,thepoolwaterprofessionaltestingforTDSmustbemadeawaresalthasbeenaddedforthechlorinatorsystem.TheindividualperformingtheTDS testwill then subtract the salinity level toarriveat thecorrectTDSlevel.
MAINTENANCE:
SAlT And CHeMICAlS IdeAl Pool CHeMISTrY reAdIngS: Swimming Pools Spas
Free Available Chlorine 1.0 – 3.0 ppm 3.0 – 5.0 ppm
pH 7.2–7.8 7.2–7.8
Total Alkalinity 100–120ppm 100–120ppm
Calcium Hardness 200–300ppm 150–200PPM
Stabilizer (Cyanuric Acid) 30 – 60 ppm 30 – 60 ppm
1. Chlorine Stabilizer (cyanuric acid): ChlorineStabilizerisneededtomaintainproperlevelsofchlorine.Most unstable chlorine is destroyed by the UV radiation fromthe sunwithin2hours. Chlorine stabilizermustbemaintainedbetween30–60PPM.
2. Nitrates:Nitrates can cause extremely high chlorine demands andwill deplete chlorine from your swimming pool. In some casesNitratesmayevenloweryourchlorinelevelstozero.YourlocalpoolprofessionalcantestforNitrates.MakesureNitratesarenotpresentinyourpool.
3. Metals:Metals can cause loss of chlorine. Also, metals can stain yourpool. Have your local pool professional check for metals andrecommendmethodsofremoval.
2. 3.
uSIng THe FronT ConTrol PAnel:
MAIN SWITCH
Refer to Figure 1 (Page 6) for a visual diagram of the front panel
1. On / Off:Fornormaloperation,theMainSwitchshouldbeleftinthe“On”position.InthispositiontheCompu-PoolCPSC/CPAwillproducechlorine according to the desired output %. Simply press thebuttonagaintoturntheunitoff.
2. Select Button: This button will allow access to the timer settings.When usingthis function the button needs to be pushed in for 3 secondsbeforetheselectbuttonwillrespond,thisisprovidedasasafetydevice.
3. SuperChlor: Whenyouhaveanabnormallyhighbatherload,alargeamountofrain,acloudywaterconditionwhichneedsalargeamountofpurification tobe introduced, simplypress theSUPERCHLORbutton. This electronically“super chlorinates” the water for 24hoursoruntilthepowerhasbeenturnedoff.
4. Winter Mode: Whenyouarenotusingyourpoolduringthewintermonths,itisadvisabletoactivatethewintermode.PresstheWINTERMODEbutton.TheWinterModewill reduce theoutputofchlorine to
50%ofsetoutput,forexample,outputis80%wintermode40%.Reducingthechlorineoutputduringperiodswhenthepool isnotinusewillhelpmaximizethelifeofthecell.
5. Manual Pump Override: To override the time clock, switch the unit off, via the powerbutton.Oncetheunitisoff,simplypresstherightchlorineoutputbutton.Thiswillallowthefilterpumptocontinually runwithoutchlorination.
6. Chlorine Output Levels: PressingthearrowbuttonleftorrightwillchangetheCHLORINEPRODUCTIONin10%increments.
7. Setting The Time: Thereare two timer functions toallow twofiltrationcyclesperday.Setthetimercyclestomeetyourdesiredrunningtimeviathechlorinatormenuwhichisaccessedbypressingtheselectbutton for 3 seconds. When setting the timer use the up anddown arrow keys to move the cursor and select the correcttime.
8. Manual Override:To manually start the unit, simply press the superchlor button.When you have finished with the manual operation pressthe superchlor button again to switch back to automaticoperation.
4. 5.
Over Salt: When illuminated, the salt level is too high. The Compu-Chlorunithasabuilt-inregulatingsystemthatenablesittocontinuetoproducechlorinewiththeincreasedsaltcontent.Atthispointdonotaddanyfurthersaltandallowthesaltcontenttoreturntodesirablelevels.
Add Salt: Whenilluminated,thesaltlevelistolowandtheunitisgeneratingatlowefficiency.Furthersaltisrequired,it isadvisabletohaveyoursaltlevelprofessionallychecked.
AddIng SAlT (sodium chloride) To Pool or SPA
do noT add pool/spa chemicals directly to the skimmer. Thismay damage the cell. Maintaining high salt levels above therecommended rangecancontribute tocorrosionofpool/spaequipment.Ifthechlorinatorhasalreadybeeninstalled,itshouldbeturnedoffbeforeaddingsalt.Compu-PoolCPSC/CPASeriesisrecommendedtorunatasaltconcentrationof3500ppm.
ForpoolsitisbesttoemptytherequiredsaltintotheshallowendofthepoolandrunthefilterandpumpsimultaneouslywhiletheCompu-Poolchlorinator isoffor inmanualmode tocirculatethewateranddissolvethesalt.Donotthrowthesaltbagintothepoolorspaaschemicalsandinksonthebagcaninterferewiththewaterbalance.
IndICATor’s led’s
Power:Whenilluminated,theCompu-Chlorunithasinputpoweractivate.
Polarity 1&2: Whenilluminated,itindicateswhichsideofthecellisproducing.
Water Fault:Whenilluminated,theflowswitchhasdetectednowaterflowingandtheCompu-Chlorunithasstoppedgeneratingchlorine.Thedisplayscreenwillread…
6. 7.
CONTROLUNIT
DISPLAYSCREEN
SELECT
OUTPUT
POWER ON
POLARITY 1
POLARITY 2
WATER FAULT
ADD SALT
OVER SALT
SUPERCHLOR WINTER MODE
1
2
7
3
6
5
4
Figure 1
Ifthepoolhasnomaindrainatthebottom,placeavacuumhoseheadinthedeepend,andsweepthesalttowardthevacuumhead.Theotherendofthevacuumhoseshouldbeplacedintheskimmerbox.RunthefilterandpumpwiththeCompu-PoolchlorinatorOFFtocirculatetheundissolvedsaltinthewater.Qualitypoolandspasalt,sodiumchloride(withlow levels of iron and other impurities) should be used, withfinergradesofsaltusuallydissolvingfaster.Saltmaytake24-48hourstodissolveinsummerandlongerinwinter.
TYPE OF SALT TO USEThepurerthesaltthebetterthelifeandperformanceoftheelectrolyticcell.Useasaltthatisatleast99.8%pureNaCl.Thepreferredsaltisanevaporated,granulated,foodquality,non-iodizedsalt.Consultyoursaltsupplier.
• Avoid using salt with anti-caking agents (sodiumferrocyanide, also known as YPS or yellow prussiate ofsoda)thatcouldcausesomediscolorationoffittingsandsurfacefinishesinpool.
• Water conditioning salt pellets are compressed forms ofevaporatedsaltandmaybeusedbutwilltakelongertodissolve.
•Donotusecalciumchlorideasasourceofsalt.(Usesodiumchlorideonly.)
• DonotuseRock salt (insoluble impuritiesmixedwith therocksaltcanshortenthelifeoftheunit).
SALT LEVELUsethechart,markedChart1 (Page11) todeterminehowmuchsaltinKgsneedstobeaddedtoreachtherecommendedlevels. Use the equations below (measurements are in feet/gallonsandmeters/litres)ifpoolsizeisunknown.
Pool and/or Spa Volume Table – Working Out How Much Salt is Required gallons litres (poolsizeinfeet) (poolsizeinmeters)
Rectangular LengthxWidthx LengthxWidthx
AverageDepthx7.5 AverageDepthx1000
Round DiameterxDiameterx DiameterxDiameterx
AverageDepthx5.9 AverageDepthx785
Oval LengthxWidthx LengthxWidthx
AverageDepthx6.7 AverageDepthx893
Theidealsaltlevelis3500ppm.Ifthelevelislow,determinethenumberofgallonsinthepoolandaddsaltaccordingtoChart1.Alowsaltlevelwillreducetheefficiencyofthechlorinatorand result in low chlorine production. A high salt level cancauseasaltytastetoyourpool.Inaddition,operatingtheunitoutsideof the recommended salt rangewill rapidly reducethelongevityofthecell.Thesaltinyourpool/spaisconstantlyrecycledandthelossofsaltthroughouttheswimmingseasonshouldbesmall.Thislossisdueprimarilytotheadditionofwater
8. 9.
becauseofsplashing,backwashing,ordraining(becauseofrain).Saltisnotlostduetoevaporation.
Ifsaltcontentistoohighyouwillneedtoreducethelevelofwaterinyourpool/spaandrefillthepool/spawithfreshwaterthathasnotbeendilutedwithsalt.
ToInitiallystartapoolwiththecorrectamountofsalt,
Add Salt to the pool at the rate of:
0.14 ounces / 0.03 Pounds of salt for every 1 uS gallon of water. or
.3.5 grams / 0.003.5 Kilograms of salt for every 1 Litre of water or
.035 Pounds of salt for every imperial gallon
WInTerIZIng
Theelectrolyticcellwillbedamagedbyfreezingwaterjustasyourpoolplumbingwould.Inareaswhichexperiencesevereorextendedperiodsoffreezingtemperatures,besuretodrainall water from the pump, filter, and supply and return linesbeforeany freezingconditionsoccur.Theelectroniccontroliscapableofwithstandinganywinterweatheranddoesnotneedberemoved.
CH
ART
1K
go
fSa
ltN
ee
de
dt
oO
bta
in3
500
pp
min
Po
olo
rSp
a(
Litr
es)
10. 11.
1000
50
00
1000
015
000
2000
030
000
4000
05
0000
60
000
7000
080
000
9000
010
0000
11
0000
12
0000
13
0000
14
0000
15
0000
3.
517
.5
35.
05
2.5
70.
01
05.0
14
0.0
175.
021
0.0
245.
028
0.0
315.
03
50.0
3
85.0
4
20.0
4
55.0
4
90.0
5
25.0
3.
015
.0
30.
04
5.0
60.
09
0.0
120.
015
0.0
180.
021
0.0
240.
027
0.0
300
.0
330
.0
360
.0
390
.0
420
.0
450
.0
2.
512
.5
25.
03
7.5
50.
07
5.0
100.
012
5.0
150.
017
5.0
200.
022
5.0
250
.0
275
.0
300
.0
325
.0
350
.0
375
.0
2.
010
.0
20.
03
0.0
40.
06
0.0
80.
010
0.0
120.
014
0.0
160.
018
0.0
200
.0
220
.0
240
.0
260
.0
280
.0
300
.0
1.
57.
51
5.0
22.
53
0.0
45.
06
0.0
75.
09
0.0
105.
012
0.0
135.
01
50.0
1
65.0
1
80.0
1
95.0
2
10.0
2
25.0
1.
05.
01
0.0
15.
02
0.0
30.
04
0.0
50.
06
0.0
70.
08
0.0
90.
01
00.0
1
10.0
1
20.0
1
30.0
1
40.0
1
50.0
0.
52.
55
.0
7.5
1
0.0
15.
02
0.0
25.
03
0.0
35.
04
0.0
45.
05
0.0
55.
06
0.0
65.
07
0.0
75.
0
Id
ea
l Id
ea
l Id
ea
l Id
ea
l Id
ea
l Id
ea
l Id
ea
l Id
ea
l Id
ea
l Id
ea
l Id
ea
l Id
ea
l Id
ea
l Id
ea
l Id
ea
l Id
ea
l Id
ea
l Id
ea
l
Salt
C
on
ce
n-
tra
tion
Be
fore
A
dd
itio
n
(pp
m)
0 500
1000
1500
2000
2500
3000
3500
No
te:C
he
ck
salt
leve
lso
fp
oo
lwa
terb
efo
rea
dd
ing
sa
lt.E
xist
ing
po
olw
ate
rma
yc
on
tain
sa
lt.
INSTALLATION:
InSTAllIng THe PoWer unITTheCPSC/CPASeriesunitistobemountedatleast3feetabovegroundlevelandifpossibleprotectedfromdirectweather.
Locate the power unit as close to the pump and filtrationsystemaspossible.Makesurethe6feetDCpowercordcanreachthesectionofpipeselectedforthecell.do not install the Power Unit within 10 feet of the pool edges.
Use the equipment provided and mount the Power Unit ateyelevel.Onceholesaredrilledintothewallandscrewsaretightly secured lift thePowerUnitonto thebracketensuringthatitissecureonthewall.
InSTAllIng THe Cell 1.Besurepoolpumpisturnedoff
2.Thecellistobefittedintothereturntopoollineafterthepumpandfilter.Waterflowshouldcomefromthefiltrationsystem through the hole marked “inlet” and back outthroughtheholemarked“outlet”.
3.Ensure barrel unions are tightened to the cell. Then glue(pressuresolventcement)pipingtothebarrelunions.
4.The cell is to be mounted horizontal with the inlets andoutletsfacingdown.Ifrequiredthecellcanbeountedvertically.
WIrIngRefertothewiringdiagrambelowtodeterminecorrectwiringconnections.TheCPSC/CPASeriesisshippedfromthefactorywith the configuration jumpers in 240VAC position. If using120VAC, move the jumpers as shown below. For Canadianmodels,theCPSC/CPASeriesshallbeconnectedtoacircuitprotected by a class A ground fault interrupter. Be sure toconnectthegroundwiretothegreengroundscrewterminallocatedonthebottomoftheenclosure.
Powermustbeshutoffatthecircuitbreakerbeforeperformingany wiring. Be sure to follow local and NEC/CEC electricalcodes.TheCompu-PoolCPSC/CPASerieshasbeendesignedtoeasilywireintotypicalin-groundpoolsystems.Toprovidesafeoperationtheunitmustbeproperlygroundedandbonded.
12. 13.
Pump Socket E
A
B
B A
Transformer
Safety Isolation Gap
J4 J1
J9J8
J13J12 J11 J7
J14 J10
J2 J5 L N
Figure 2.1 Internal Transformer Connections - 115VACConnections
FILT
ER
Figure 2.2 WIrIng
CPS
C/C
PA S
erie
sFI
LTER
TIM
ER
CEL
L
PUM
P
HEA
TER
In-F
loo
rC
LEA
NER
FRO
MPO
OL
FRO
MSP
A
TO SPA
SOLA
RSY
STEM
14. 15.
INPUT POWERThe Compu Pool CPSC/CPA Series comes with a terminatedpower cord that should be plugged directly into the externaltimeclockunit.ForCanadian installations:ConnecttoacircuitprotectedbyaClass-Agroundfaultinterrupter.
BondIngA lug for bonding is attached to the bottom of the Compu-PoolCPSC/CPASeriesenclosure.Connecttothepoolbondingsystemusingminimum8AWGcopperwireifrequiredbycode.
BondIng lug
Figure 2.3 BondIng
Cell Cord
POWER Cord
CPSC/CPA Series
ELECTROLYTIC CELL
TheCelloperatesmostefficientlywhenitisclean,sotheautocellcleaningwillkeepthecellfreeofthewhitecalciumbuildupcommontostandardchlorinators.Howevercheckingandpossibly cleaning any foreign buildup every six months willmaintainfullchlorineoutputandprolongcelllife.
dISMAnTlIng THe CellWhenremovingthecellforcleaningorreplacement:
1.TurnallACpoweroff
2.Removethecellplugconnectingthecelltothepowerunit
3.Loosen the barrel unions, connecting the cell to thePVCpiping. Loosenby turning inancounterclockwisedirection.Oncethebarrelunionsareloosenedremovethecellenclosurecontainingthecell.
4.Removetheouterbluecoverbyholdingupsidedownwiththecellheadfacingawayfromyou.Thensimplypullthetwoblueoutercoversapart.
5.Toremovethecell, loosenandremovethegreyPVClockingring.
6.Removecellfromclearhousing.
CleAnIng THe CellTocleantheCell, ifanyforeignbuildupisvisible, immersethecell plates into a solution of five parts water and one parthydrochloricacid.Leaveforafewminutesthenhoseoffuntilcellplates are clean. do not submerse cell head when cleaning.
WArnIng: For quality and value - insist your chlorinator is only serviced with genuine replacement parts available from the manufacturer - Compu Pool Products
INSTALLATION CHECK LIST:
YourCompuPoolSaltWaterGeneratorinstallationiscompletewhenthefollowinghavebeencompleted:
•Barrelunionsinstalledandgluedintopipework
•Barrelunionsconnectedtothecellhousing
•Cellisproperlyplacedintothecellhousing
•The metal backing bracket is affixed to the wall orbacking
•Thepowerunitismountedinplacetothemetalbacking bracket
•Cell cord is connected to the power unit and is also pluggedintothecell
•Sufficientsaltisdissolvedintopoolwater
•Youhavecheckedandconfirmedthatyourpowerunit switchesONandOFFcoincidentallywiththefilterpump
•Youhavecheckedallconnectionsandjointsforleaks
16. 17.
HELPFUL HINTS:
When the chlorine output is at 100% and the Cell is clean,then the chlorinator is producing chlorine. However, if thepoolremainscloudyorthechlorineresidualtestslow,thenthechlorinebeingproducedislostduetohighchlorinedemand.
Toreducethechlorinedemand,checkthepHreadingandcheckfor loworhighstabilizerreading. If testsshowcorrect,thenashocktreatmentisadvisedwithanoxidizieragent.
Generally, superchlorination is not necessary if the pool ismaintainedatcorrectlevels.
deFInITIonS:Algae
Plant-like organisms which grow in water. Especially active insummerconditions,wherechlorinedisinfectantlevelistoolow to destroy them. Algae may be green, brown or black(BlackSpot)incolor.
Chlorine demandTheamountofchlorine that shouldbeadded to thewater toprovideproperbacteriaandalgaecontrol.
Chlorine ResidualThe amount of chlorine left over, after the “demand” has beenmet.
Combined ChlorineWeakchlorinewhich iscombinedwith thecontaminants in
thewater.
Free ChlorineActive chlorine in the water with the potency to destroycontaminants.
Shock TreatmentThe removal by means of oxidation of those materials thathavechlorinedemand.
SuperchlorinationAnextralargeamountofchlorineaddedtothewater.
reCoMMendATIonS And HelPFul HInTS:Recommended List •Readandkeepyourmanualinasafeplace.
• IncreaseChlorineProductionwhentemperaturegoesup.
• IncreaseChlorineProductionwhennumberofguestsgoesup.
•UseStabilizer(CyanuricAcid)toProtectChlorineinPool.
• Mount Power Unit in shade or out of the direct sunlightwheneverpossible.
•Decrease Production when temperature goes down. Forexamplewinter.
•TakepoolwatersampletoPoolProfessionalonceper month.
Not Recommended ListDo not get fertilizer in your pool. Fertilizers contain nitrateswhichcauseahighchlorinedemandonpoolwater.
NeverusedryacidtoadjustpHinaridgeographicareaswith
18. 19.
PROBLEM POSSIBLE CAUSE
(1 ) CHLORINE RESIDUAL
LOWorNIL •Insufficientrunningtimes
•pHtoohigh
•Insufficientstabilizer
•Cellneedscleaning
•Checkchlorineproduction
(2) CHLORINE PRODUCTION LOWorNIL
•Chlorinedialturneddown
•Saltcontentbelow0.25%
•Cellneedscleaning
•CheckCellconnections atjunctionboxunderunit
•Checkfuseonpowerunit
•Checkfilterpumprunning
•Checkwaterflowthrough Cellissufficient
(3) WATERFLOWTHROUGH CELLISLOW
•Checkforairinsystem
•Checkoperationofpump
•Checkfilterisclean
•Checkwaterlevelofpool
•CheckforblockageinSystem
excessive evaporation and minimal dilution of pool waterwithfreshwater.Abuildupofbyproductscandamagetheelectrolyticcell.
Donotaddanypoolwaterbalancingchemicals(includingsalt)unlesstheChlorinatoristurnedoff.
DonotletChlorineStabilizerdropbelow3000PPM.
TrouBle SHooTIng
• Power led and lCd screen not turning on Checktomakesureeither120VACor240VACinput powerisconnectedtotheproperscrewterminalsat thecontrol.Verifyinputvoltagewithavoltmeter.Ifthere isinputpower,thefusemayhaveblown.TheCPSC/ CPASeriesisprotectedbya3.5ampminiATOfuse locatedonthebottomofthepowercircuitboard.
• Water Fault led illuminated TheCPSC/CPASerieshassensedanoflowconditionand hasstoppedgeneratingchlorine.Checkthatthereiswater inthecellenclosure.Ifthereisadequateflowandthe LEDisstillon,checkthatsalthasbeenaddedtothepool. Ifnosalthasbeenaddedthewaterfaultlightillbe illuminated.IftheLEDisstillilluminatedcheckthe connectionbetweenthecellplugandthebrassterminals istight.
20. 21.
WARRANTY:
The Compu-Pool automatic salt water generator modelCPSC/CPA Series carries the following warranty should faultoccurduetofaultymanufacturingormaterials.
CompuPoolProductswarrantstheoriginalpurchaseroftheunitforaperiodof2fullyearsand1yearprorataor8,000hoursofoperationonthepowerunitandonthecellfromthedateofpurchasebytheoriginalowners,shouldexaminationdisclosetoitssatisfactiontheunithasfailedduetofaultymanufacturing or materials.
The warranty may be void if the following occurs:1.DamagetotheunitbeyondCompuPoolProduct’scontrol.
2. Ifcorrectpoolchemistryisnotmaintained.
3. ThePowerUnitandCellarenotinstalledcorrectlybyany personotherthanapersonauthorizedtodosobyCompu Pool Products or its agent.
4. Allwearingpartswhichmustberegularlycheckedand replacedwhennaturallyworn.
5. The Electrolytic Cell is not cleaned regularly or cleaned byanyothermethodotherthanbythemethod recommendedbythemanufacturer.
6. The Chlorinator Power Unit and Cell is serviced by any otherpersonotherthanapersonauthorizedtodosoby Compu Pool Products or its agent.
This warranty is applicable to workmanship and materials only.CompuPoolProductsor itsagentwill replaceatnochargeallparts return freight paid, which display faulty workmanship ormaterials.
Compu Pool Products or its agent accept no responsibilityforloss,damageorinjuriestopersonorpropertyarisingfromwarrantyfailureofequipment,orinstallationofthatequipment,unlesswiththeauthorityofCompuPoolProductsoritsagent.This warranty shall not extend to any expenditure otherwiseincurred.
rePlACIng THe CellWhenreplacingthecell,onlyusereplacementcellshavingalabelthatclearlystatesthatitisagenuinereplacementcellfortheCompu-PoolCPSC/CPASeries.
22. 23.