COMMERCIAL CEMENT PLASTER 5 DS828 - Dryvit · dryvit commercial cement plaster base™ (note 1)...
Transcript of COMMERCIAL CEMENT PLASTER 5 DS828 - Dryvit · dryvit commercial cement plaster base™ (note 1)...
COMMERCIAL CEMENT PLASTER 5™
DS828
A Furred Rainscreen, Fiberglass Reinforced Portland Cement Plaster with Backstop® NT Air/Water-Resistive Barrier and Reinforced Surface Impact Layer
Commercial Cement Plaster 5 Installation Details
TABLE OF CONTENTS
Cement Plaster Control Joints
Termination at- Deck
Termination at- Parapet/ Wall Intersection
Termination at- Roof/ Wall Intersection
Termination at Roof/ Parapet
Termination at Dryer Vent
Termination at Storefront Window- Sill/ Jamb
Termination at Flanged Window- Sill/ Jamb
Floor Line Joint With Flashing
CCP 5 Cutaway
System Installation at Window
Termination at Railing Attachment
Termination at Soffit
DETAIL
CCP-5 0.0.14
CCP-5 0.0.16
CCP-5 0.0.15
CCP-5 0.0.08
CCP-5 0.0.09
CCP-5 0.0.12
CCP-5 0.0.13
CCP-5 0.0.11
CCP-5 0.0.07
CCP-5 0.0.10
CCP-5 0.0.04
PAGE
CCP-5 0.0.01
CCP-5 0.0.02
CCP-5 0.0.05
DRYVIT MAKES NO REPRESENTATION REGARDING CONFORMITY OFITS SUGGESTIONS TO MODEL BUILDING CODES, ENGINEERINGCRITERIA, SPECIFIC APPLICATIONS OR PROJECT LOCATIONS. ALLCOMPONENTS INDICATED IN ILLUSTRATIONS, AS WELL ASOTHERS THAT MAY BE REQUIRED FOR THE INTEGRITY OF THESYSTEM SHALL BE DESIGNED, DETAILED AND ENGINEERED BYREPRESENTATIVES OF THE ARCHITECT, OWNER OR CONTRACTORTO BE IN CONFORMANCE WITH MODEL CODES, ARCHITECTURALAND ENGINEERING REQUIREMENTS PERTAINING TO SPECIFICBUILDING PROJECTS.
DRYVIT MAKES NO WARRANTY, EXPRESSED OR IMPLIED, AS TOTHE ARCHITECTURAL DESIGN, ENGINEERING, OR WORKMANSHIP OFPROJECTS UTILIZING DRYVIT SYSTEMS OR PRODUCTS.
THE LIABILITIES OF DRYVIT SHALL BE AS STATED IN THEDRYVIT STANDARD WARRANTY. CONTACT DRYVIT FOR A FULLAND COMPLETE COPY OF THIS WARRANTY.
NOTE
Termination at Flanged Window- Head/ Jamb
CCP-5 0.0.06
Termination at Storefront Window- Head/ Jamb
Opening Preparation- Backstopâ NT/Aquaflashâ System
CCP-5 0.0.03
The architecture, engineering, and design of the project using the
Dryvit products is the responsibility of the project's design
professional. All systems must comply with local building codes and
standards. This detail is for general information and guidance only
and Dryvit specifically disclaims any liability for the use of this detail
and for the architecture, design, engineering or workmanship of any
project. The project design professional determines, in its sole
discretion, whether this detail or a functionally equivalent detail is
best suited for the project. Use of a functionally equivalent detail does
not violate Dryvit's warranty. This detail is subject to change without
notice. Contact Dryvit to ensure you have the most recent version.
Commercial Cement Plaster 5™
©
Dryvit Systems, Inc. 1969
Issued: 10/2016
CCP-5 0.0.01
CCP 5 Cutaway
CODE APPROVED SHEATHING (BY OTHERS)
PRESSURE TREATED WOODSTRAPPING OR EQUAL (BY OTHERS)
DRYVIT BACKSTOP® NTAIR/WATER-RESISTIVE BARRIER
BREATHER/BACKER BOARD (BY OTHERS)
GALVANIZED SELF-FURRING LATH (BY OTHERS)(NOTE 2)DRYVIT COMMERCIAL CEMENT PLASTER BASE™(NOTE 1)DRYVIT REINFORCING MESHEMBEDDED IN DRYVIT GENESIS® ORGENESIS DM™
DRYVIT PRIMER
DRYVIT FINISH
DRYVIT AQUAFLASH® SYSTEM
INSECT SCREEN (BY OTHERS)
CASING BEAD WITH WEEPS (BY OTHERS)
CONTINUOUS METAL FLASHING (BY OTHERS)
1. OTHER APPROVED SCRATCH ANDBROWN COATS MAY BE ACCEPTABLE.CONSULT DRYVIT SYSTEMS, INC. FORSPECIFICS.
NOTE:
2. PAPER BACKED LATH OR OTHER SLIP SHEETMAY BE REQUIRED OVER CERTAIN SUBSTRATES.
The architecture, engineering, and design of the project using the
Dryvit products is the responsibility of the project's design
professional. All systems must comply with local building codes and
standards. This detail is for general information and guidance only
and Dryvit specifically disclaims any liability for the use of this detail
and for the architecture, design, engineering or workmanship of any
project. The project design professional determines, in its sole
discretion, whether this detail or a functionally equivalent detail is
best suited for the project. Use of a functionally equivalent detail does
not violate Dryvit's warranty. This detail is subject to change without
notice. Contact Dryvit to ensure you have the most recent version.
Commercial Cement Plaster 5™
©
Dryvit Systems, Inc. 1969
Issued: 10/2016
CCP-5 0.0.02
Floor Line Joint With Flashing
GALVANIZED SELF FURRINGLATH (BY OTHERS) (NOTE 2)DRYVIT COMMERCIAL CEMENT PLASTER BASEä,(NOTE1)DRYVIT REINFORCING MESH EMBEDDED INGENESIS® OR GENESIS DM™, PRIMER AND FINISH
CODE APPROVED SHEATHING (BY OTHERS)
PRESSURE TREATED WOODSTRAPPING OR EQUAL (BY OTHERS)
DRYVIT BACKSTOP® NTAIR/WATER-RESISTIVE BARRIER
BREATHER/BACKER BOARD (BY OTHERS)
METAL FLASHING (BY OTHERS)
S-LOCK OR STANDING SEAM JOINT (BY OTHERS)
INSECT SCREEN (BY OTHERS)
DRYVIT AQUAFLASHâ SYSTEM
EXPANSION JOINT
SEALANT (BY OTHERS)
1. OTHER APPROVED SCRATCH ANDBROWN COATS MAY BE ACCEPTABLE.CONSULT DRYVIT SYSTEMS, INC. FORSPECIFICS.
NOTE:
2. PAPER BACKED LATH OR OTHER SLIP SHEETMAY BE REQUIRED OVER CERTAIN SUBSTRATES.
The architecture, engineering, and design of the project using the
Dryvit products is the responsibility of the project's design
professional. All systems must comply with local building codes and
standards. This detail is for general information and guidance only
and Dryvit specifically disclaims any liability for the use of this detail
and for the architecture, design, engineering or workmanship of any
project. The project design professional determines, in its sole
discretion, whether this detail or a functionally equivalent detail is
best suited for the project. Use of a functionally equivalent detail does
not violate Dryvit's warranty. This detail is subject to change without
notice. Contact Dryvit to ensure you have the most recent version.
Commercial Cement Plaster 5™
©
Dryvit Systems, Inc. 1969
Issued: 10/2016
CCP-5 0.0.03
INSTALL DIAGONAL STRIPOF DRYVIT AQUAFLASHMESH AND AQUAFLASHAT CORNERS(NOTES 1 AND 3)
APPLY DRYVIT AQUAFLASHSYSTEM (NOTES 1 AND 3)
DRYVIT BACKSTOP NTAIR/WATER-RESISTIVEBARRIER COATING
STEP #1 STEP #2
INSTALL DRYVIT AQUAFLASHSYSTEM AT JAMBS(NOTES 1 AND 3)
STEP #3 STEP #4
1. DRYVIT AQUAFLASH SHALL EXTEND TOINTERIOR FACE OF OPENING.REFER TO HEAD, SILL AND JAMBDETAILS FOR FLASHING INTEGRATION.
2.
3. INSTALL WINDOW UNIT AND ASSOCIATED FLASHINGS PER MANUFACTURER'S RECOMMENDATIONS, CODE REQUIREMENTS AND PROJECT DOCUMENTS.
NOTE:
INSTALL DRYVITAQUAFLASH SYSTEMAT HEADS(NOTES 1, 2, AND 3)
Opening Preparation-
Backstopâ NT/AquaFlash® System
The architecture, engineering, and design of the project using the
Dryvit products is the responsibility of the project's design
professional. All systems must comply with local building codes and
standards. This detail is for general information and guidance only
and Dryvit specifically disclaims any liability for the use of this detail
and for the architecture, design, engineering or workmanship of any
project. The project design professional determines, in its sole
discretion, whether this detail or a functionally equivalent detail is
best suited for the project. Use of a functionally equivalent detail does
not violate Dryvit's warranty. This detail is subject to change without
notice. Contact Dryvit to ensure you have the most recent version.
Commercial Cement Plaster 5™
©
Dryvit Systems, Inc. 1969
Issued: 10/2016
CCP-5 0.0.04
System Installation at Window
INSTALL WINDOW, SILL AND HEAD FLASHINGAND APPLY DRYVIT AQUAFLASHâ SYSTEMOVER HEAD FLASHING
INSTALL STRAPPING AND CEMENT PLASTERSYSTEM
The architecture, engineering, and design of the project using the
Dryvit products is the responsibility of the project's design
professional. All systems must comply with local building codes and
standards. This detail is for general information and guidance only
and Dryvit specifically disclaims any liability for the use of this detail
and for the architecture, design, engineering or workmanship of any
project. The project design professional determines, in its sole
discretion, whether this detail or a functionally equivalent detail is
best suited for the project. Use of a functionally equivalent detail does
not violate Dryvit's warranty. This detail is subject to change without
notice. Contact Dryvit to ensure you have the most recent version.
Commercial Cement Plaster 5™
©
Dryvit Systems, Inc. 1969
Issued: 10/2016
CCP-5 0.0.05
Termination at Flanged Window- Sill/Jamb
GALVANIZED SELF-FURRING LATH (BY OTHERS)(NOTE 2)
DRYVIT COMMERCIAL CEMENT PLASTER BASEä,(NOTE 1)DRYVIT REINFORCING MESH EMBEDDED IN DRYVITGENESIS® OR GENESIS DM™
CODE APPROVED SHEATHING (BY OTHERS)
DRYVIT BACKSTOP® NT AIR/WATER-RESISTIVEBARRIER
BREATHER/BACKER BOARD (BY OTHERS)
PRESSURE TREATED WOODSTRAPPING OR EQUAL (BY OTHERS)
DRYVIT AQUAFLASHâ SYSTEMCONTINUOUS WINDOW PERIMETER STRAPPING(BY OTHERS)
MIN. 13MM (1/2") SEALANT JOINT WITHCLOSED CELL BACKER ROD (BY OTHERS)WINDOW BASE FLASHING WITH END DAMS (BY OTHERS)
METAL ANGLE (BY OTHERS)
INTERMITTENT SHIM (BY OTHERS)
SEALANT (BY OTHERS)
DRYVIT PRIMER AND DRYVIT FINISH
1. OTHER APPROVED SCRATCH ANDBROWN COATS MAY BE ACCEPTABLE.CONSULT DRYVIT SYSTEMS, INC. FORSPECIFICS.
NOTE:
2. PAPER BACKED LATH OR OTHER SLIP SHEETMAY BE REQUIRED OVER CERTAIN SUBSTRATES.
The architecture, engineering, and design of the project using the
Dryvit products is the responsibility of the project's design
professional. All systems must comply with local building codes and
standards. This detail is for general information and guidance only
and Dryvit specifically disclaims any liability for the use of this detail
and for the architecture, design, engineering or workmanship of any
project. The project design professional determines, in its sole
discretion, whether this detail or a functionally equivalent detail is
best suited for the project. Use of a functionally equivalent detail does
not violate Dryvit's warranty. This detail is subject to change without
notice. Contact Dryvit to ensure you have the most recent version.
Commercial Cement Plaster 5™
©
Dryvit Systems, Inc. 1969
Issued: 10/2016
CCP-5 0.0.06
GALVANIZED SELF FURRING LATH (BY OTHERS)
DRYVIT COMMERCIAL CEMENT PLASTER BASEä,(NOTE 1)DRYVIT REINFORCING MESH EMBEDDED IN DRYVITGENESIS® OR GENESIS DM™ BASE COAT
CODE APPROVED SHEATHING (BY OTHERS)
DRYVIT BACKSTOP® NTAIR/WATER-RESISTIVE BARRIER
BREATHER/BACKER BOARD (BY OTHERS)
PRESSURE TREATED WOODSTRAPPING OR EQUAL (BY OTHERS)
DRYVIT AQUAFLASHâ SYSTEM AT JAMBS
CONTINUOUS WINDOW PERIMETER STRAPPING (BY OTHERS)
MIN. 13MM (1/2 IN) SEALANT JOINT WITHCLOSED CELL BACKER ROD (BY OTHERS)
INSECT SCREEN (BY OTHERS)
WINDOW HEAD FLASHING WITH END DAMS (BY OTHERS)
DRYVIT PRIMER AND DRYVIT FINISH
1. OTHER APPROVED SCRATCH ANDBROWN COATS MAY BE ACCEPTABLE.CONSULT DRYVIT SYSTEMS, INC. FORSPECIFICS.
NOTE:The architecture, engineering, and design of the project using the
Dryvit products is the responsibility of the project's design
professional. All systems must comply with local building codes and
standards. This detail is for general information and guidance only
and Dryvit specifically disclaims any liability for the use of this detail
and for the architecture, design, engineering or workmanship of any
project. The project design professional determines, in its sole
discretion, whether this detail or a functionally equivalent detail is
best suited for the project. Use of a functionally equivalent detail does
not violate Dryvit's warranty. This detail is subject to change without
notice. Contact Dryvit to ensure you have the most recent version.
Commercial Cement Plaster 5™
©
Dryvit Systems, Inc. 1969
Issued: 10/2016
Termination at
Flanged Window-Head/Jamb
CCP-5 0.0.07
Termination at Storefront Window-Sill/Jamb
GALVANIZED SELF FURRING LATH (BY OTHERS) (NOTE 2)
DRYVIT COMMERCIAL CEMENT PLASTER BASEä (NOTE 1)DRYVIT REINFORCING MESH EMBEDDED IN DRYVITGENESIS® OR GENESIS DM™ BASE COAT
CODE APPROVED SHEATHING (BY OTHERS)
DRYVIT BACKSTOP® NTAIR/WATER-RESISTIVE BARRIER
BREATHER/BACKER BOARD (BY OTHERS)
PRESSURE TREATED WOODSTRAPPING OR EQUAL (BY OTHERS)
DRYVIT AQUAFLASHâ SYSTEM AT JAMBS
MIN. 13MM (1/2 IN) SEALANT JOINT WITHCLOSED CELL BACKER ROD (BY OTHERS)
METAL PAN FLASHING (BY OTHERS)
INTERMITTENT SHIM (BY OTHERS)
CONTINUOUS WINDOW PERIMETER STRAPPING (BY OTHERS)
DRYVIT PRIMER AND FINISH
1. OTHER APPROVED SCRATCH ANDBROWN COATS MAY BE ACCEPTABLE.CONSULT DRYVIT SYSTEMS, INC. FORSPECIFICS.
NOTE:
2. PAPER BACKED LATH OR OTHER SLIP SHEETMAY BE REQUIRED OVER CERTAIN SUBSTRATES.
The architecture, engineering, and design of the project using the
Dryvit products is the responsibility of the project's design
professional. All systems must comply with local building codes and
standards. This detail is for general information and guidance only
and Dryvit specifically disclaims any liability for the use of this detail
and for the architecture, design, engineering or workmanship of any
project. The project design professional determines, in its sole
discretion, whether this detail or a functionally equivalent detail is
best suited for the project. Use of a functionally equivalent detail does
not violate Dryvit's warranty. This detail is subject to change without
notice. Contact Dryvit to ensure you have the most recent version.
Commercial Cement Plaster 5™
©
Dryvit Systems, Inc. 1969
Issued: 10/2016
CCP-5 0.0.08
GALVANIZED SELF FURRING LATH (BY OTHERS) (NOTE 2)
DRYVIT COMMERCIAL CEMENT PLASTER BASEä (NOTE 1)DRYVIT REINFORCING MESH EMBEDDED IN DRYVITGENESIS® OR GENESIS DM™ BASE COAT
CODE APPROVED SHEATHING (BY OTHERS)
DRYVIT BACKSTOP® NTAIR/WATER-RESISTIVE BARRIER
BREATHER/BACKER BOARD (BY OTHERS)
PRESSURE TREATED WOODSTRAPPING OR EQUAL (BY OTHERS)
DRYVIT FLASHING TAPE AT JAMBS
CONTINUOUS WINDOW PERIMETER STRAPPING (BY OTHERS)
MIN. 13MM (1/2 IN) SEALANT JOINT WITHCLOSED CELL BACKER ROD (BY OTHERS)
INSECT SCREEN (BY OTHERS)
WINDOW HEAD FLASHING WITH END DAMS (BY OTHERS)
DRYVIT PRIMER AND FINISH
1. OTHER APPROVED SCRATCH ANDBROWN COATS MAY BE ACCEPTABLE.CONSULT DRYVIT SYSTEMS, INC. FORSPECIFICS.
NOTE:
2. PAPER BACKED LATH OR OTHER SLIP SHEETMAY BE REQUIRED OVER CERTAIN SUBSTRATES.
The architecture, engineering, and design of the project using the
Dryvit products is the responsibility of the project's design
professional. All systems must comply with local building codes and
standards. This detail is for general information and guidance only
and Dryvit specifically disclaims any liability for the use of this detail
and for the architecture, design, engineering or workmanship of any
project. The project design professional determines, in its sole
discretion, whether this detail or a functionally equivalent detail is
best suited for the project. Use of a functionally equivalent detail does
not violate Dryvit's warranty. This detail is subject to change without
notice. Contact Dryvit to ensure you have the most recent version.
Commercial Cement Plaster 5™
©
Dryvit Systems, Inc. 1969
Issued: 10/2016
Termination at
Storefront Window-Head/Jamb
CCP-5 0.0.09
Termination at Railing Attachment
GALVANIZED SELF-FURRING LATH (BY OTHERS)(NOTE 2)DRYVIT COMMERCIAL CEMENT PLASTER BASEä(NOTE 1)DRYVIT REINFORCING MESH EMBEDDED IN DRYVITGENESIS® OR GENESIS DM™ BASE COAT
CODE APPROVED SHEATHING (BY OTHERS)
DRYVIT BACKSTOP® NTAIR/WATER-RESISTIVE BARRIER
BREATHER/BACKER BOARD (BY OTHERS)
PRESSURE TREATED WOODSTRAPPING OR EQUAL (BY OTHERS)
DRYVIT AQUAFLASHâ SYSTEM
MIN. 13MM (1/2 IN) SEALANT JOINT WITHCLOSED CELL BACKER ROD (BY OTHERS)
BLOCKING SLOPED SIDEWISE (BY OTHERS)
SLEEVE, STRUCTURALBACKING (BY OTHERS)
RAILING (BY OTHERS)
DRYVIT PRIMER AND FINISH
1. OTHER APPROVED SCRATCH ANDBROWN COATS MAY BE ACCEPTABLE.CONSULT DRYVIT SYSTEMS, INC. FORSPECIFICS.
NOTE:
2. PAPER BACKED LATH OR OTHER SLIP SHEETMAY BE REQUIRED OVER CERTAIN SUBSTRATES.
©
The architecture, engineering, and design of the project using the
Dryvit products is the responsibility of the project's design
professional. All systems must comply with local building codes and
standards. This detail is for general information and guidance only
and Dryvit specifically disclaims any liability for the use of this detail
and for the architecture, design, engineering or workmanship of any
project. The project design professional determines, in its sole
discretion, whether this detail or a functionally equivalent detail is
best suited for the project. Use of a functionally equivalent detail does
not violate Dryvit's warranty. This detail is subject to change without
notice. Contact Dryvit to ensure you have the most recent version.
Commercial Cement Plaster 5™
©
Dryvit Systems, Inc. 1969
Issued: 10/2016
CCP-5 0.0.10
Termination at Dryer Vent
1. OTHER APPROVED SCRATCH ANDBROWN COATS MAY BE ACCEPTABLE.CONSULT DRYVIT SYSTEMS, INC. FOR
SPECIFICS.
NOTE:
2. PAPER BACKED LATH OR OTHER SLIP SHEETMAY BE REQUIRED OVER CERTAIN SUBSTRATES.
The architecture, engineering, and design of the project using the
Dryvit products is the responsibility of the project's design
professional. All systems must comply with local building codes and
standards. This detail is for general information and guidance only
and Dryvit specifically disclaims any liability for the use of this detail
and for the architecture, design, engineering or workmanship of any
project. The project design professional determines, in its sole
discretion, whether this detail or a functionally equivalent detail is
best suited for the project. Use of a functionally equivalent detail does
not violate Dryvit's warranty. This detail is subject to change without
notice. Contact Dryvit to ensure you have the most recent version.
Commercial Cement Plaster 5™
©
Dryvit Systems, Inc. 1969
Issued: 10/2016
GALVANIZED SELF FURRING LATH (BY OTHERS) (NOTE 2)
DRYVIT COMMERCIAL CEMENT PLASTER BASEä(NOTE1)DRYVIT REINFORCING MESH EMBEDDED INGENESIS® OR GENESIS DM BASE COAT
CODE APPROVED SHEATHING (BY OTHERS)
DRYVIT BACKSTOP® NTAIR/WATER-RESISTIVE BARRIER
BREATHER/BACKER BOARD (BY OTHERS)
PRESSURE TREATED WOODSTRAPPING OR EQUAL (BY OTHERS)
DRYVIT AQUAFLASHâ SYSTEM OVER VENT FLANGE
MIN. 13MM (1/2 IN) SEALANT JOINT WITHCLOSED CELL BACKER ROD (BY OTHERS)INSECT SCREEN (BY OTHERS)
DRYER VENT HOOD, SLOPED AT TOP (BY OTHERS)
DRYVIT PRIMER AND FINISH
CCP-5 0.0.11
Termination at Roof/Parapet
CASING BEAD (BY OTHERS)
65MM (2 1/2 IN) MIN.
200MM (8 IN) MIN. FROM ROOF LINE
INSECT SCREEN (BY OTHERS)
CODE APPROVED SHEATHING (BY OTHERS)
DRYVIT BACKSTOP® NTAIR/WATER-RESISTIVE BARRIERBREATHER/BACKER BOARD (BY OTHERS)
DRYVIT COMMERCIAL CEMENT PLASTER BASEä(NOTE 1)DRYVIT REINFORCING MESH EMBEDDED INDRYVIT GENESIS® OR GENESIS DM™ BASE COAT
METAL CAP FLASHING (BY OTHERS)
PARAPET FLASHING MEMBRANE (BY OTHERS)
PRESSURE TREATED BLOCKING (BY OTHERS)
DRYVIT BACKSTOP® NTAIR/WATER-RESISTIVE BARRIER
DRYVIT AQUAFLASHâ SYSTEM
BREATHER/BACKER BOARD (BY OTHERS)
ROOFING MEMBRANE (BY OTHERS)
SEALANT UNDER UPTURNED LEG (BY OTHERS)
13MM (1/2 IN) MIN. SEALANT JOINT (BY OTHERS)
DRYVIT PRIMER AND FINISH
DRYVIT COMMERCIAL CEMENT PLASTER BASEä,(NOTE 1)
DRYVIT REINFORCING MESH EMBEDDED INDRYVIT GENESIS® OR GENESIS DM™, BASECOAT
DRYVIT PRIMER AND FINISH
1. OTHER APPROVED SCRATCH ANDBROWN COATS MAY BE ACCEPTABLE.CONSULT DRYVIT SYSTEMS, INC. FORSPECIFICS.
NOTE:
2. PAPER BACKED LATH OR OTHER SLIP SHEETMAY BE REQUIRED OVER CERTAIN SUBSTRATES.
GALVANIZED SELF FURRING LATH (BY OTHERS) (NOTE 2)
The architecture, engineering, and design of the project using the
Dryvit products is the responsibility of the project's design
professional. All systems must comply with local building codes and
standards. This detail is for general information and guidance only
and Dryvit specifically disclaims any liability for the use of this detail
and for the architecture, design, engineering or workmanship of any
project. The project design professional determines, in its sole
discretion, whether this detail or a functionally equivalent detail is
best suited for the project. Use of a functionally equivalent detail does
not violate Dryvit's warranty. This detail is subject to change without
notice. Contact Dryvit to ensure you have the most recent version.
Commercial Cement Plaster 5™
©
Dryvit Systems, Inc. 1969
Issued: 10/2016
CCP-5 0.0.12
Termination at Roof/Wall Intersection
GALVANIZED SELF FURRING LATH (BY OTHERS)(NOTE 2)DRYVIT COMMERCIAL CEMENT PLASTER BASEä(NOTE1)DRYVIT REINFORCING MESH EMBEDDED IN DRYVITGENESIS® OR GENESIS DM™ BASE COAT
CODE APPROVED SHEATHING (BY OTHERS)
DRYVIT BACKSTOP® NTAIR/WATER-RESISTIVE BARRIER
BREATHER/BACKER BOARD (BY OTHERS)
PRESSURE TREATED WOODSTRAPPING OR EQUAL (BY OTHERS)
DRYVIT AQUAFLASHâ SYSTEM
STEP FLASHING (BY OTHERS)
DIVERTER FLASHING (BY OTHERS)
50MM (2 IN) MIN.
MIN. 13MM (1/2 IN) SEALANT (BY OTHERS)
DRYVIT PRIMER AND FINISH
1. OTHER APPROVED SCRATCH ANDBROWN COATS MAY BE ACCEPTABLE.CONSULT DRYVIT SYSTEMS, INC. FORSPECIFICS.
NOTE:
2. PAPER BACKED LATH OR OTHER SLIP SHEETMAY BE REQUIRED OVER CERTAIN SUBSTRATES.
The architecture, engineering, and design of the project using the
Dryvit products is the responsibility of the project's design
professional. All systems must comply with local building codes and
standards. This detail is for general information and guidance only
and Dryvit specifically disclaims any liability for the use of this detail
and for the architecture, design, engineering or workmanship of any
project. The project design professional determines, in its sole
discretion, whether this detail or a functionally equivalent detail is
best suited for the project. Use of a functionally equivalent detail does
not violate Dryvit's warranty. This detail is subject to change without
notice. Contact Dryvit to ensure you have the most recent version.
Commercial Cement Plaster 5™
©
Dryvit Systems, Inc. 1969
Issued: 10/2016
CCP-5 0.0.13
Termination at Parapet/Wall Intersection
GALVANIZED SELF FURRING LATH (BY OTHERS (NOTE 2))DRYVIT COMMERCIAL CEMENT PLASTER BASEä(NOTE1)DRYVIT REINFORCING MESH EMBEDDED IN DRYVITGENESIS® OR GENESIS DM™ BASE COAT
CODE APPROVED SHEATHING (BY OTHERS)
DRYVIT BACKSTOP® NTAIR/WATER-RESISTIVE BARRIER
BREATHER/BACKER BOARD (BY OTHERS)
PRESSURE TREATED WOODSTRAPPING OR EQUAL (BY OTHERS)
SADDLE FLASHING WITH SEALANTUNDER UP TURNED LEG (BY OTHERS)
DRYVIT AQUAFLASH® SYSTEM LAPPED OVERMETAL SADDLE FLASHING UP TURNED LEG
BLOCKING SLOPED FOR DRAINAGE (BY OTHERS)
RETAINING CLIP (BY OTHERS)
PARAPET MEMBRANE (BY OTHERS)
DRYVIT PRIMER AND FINISH
1. OTHER APPROVED SCRATCH ANDBROWN COATS MAY BE ACCEPTABLE.CONSULT DRYVIT SYSTEMS, INC. FORSPECIFICS.
NOTE:
2. PAPER BACKED LATH OR OTHER SLIP SHEETMAY BE REQUIRED OVER CERTAIN SUBSTRATES.
The architecture, engineering, and design of the project using the
Dryvit products is the responsibility of the project's design
professional. All systems must comply with local building codes and
standards. This detail is for general information and guidance only
and Dryvit specifically disclaims any liability for the use of this detail
and for the architecture, design, engineering or workmanship of any
project. The project design professional determines, in its sole
discretion, whether this detail or a functionally equivalent detail is
best suited for the project. Use of a functionally equivalent detail does
not violate Dryvit's warranty. This detail is subject to change without
notice. Contact Dryvit to ensure you have the most recent version.
Commercial Cement Plaster 5™
©
Dryvit Systems, Inc. 1969
Issued: 10/2016
CCP-5 0.0.14
Termination at Deck
INSECT SCREEN (BY OTHERS)
DRYVIT COMMERCIAL CEMENT PLASTER BASEä (NOTE 1)DRYVIT REINFORCING MESH EMBEDDED IN DRYVITGENESIS® OR GENESIS DM™ BASE COAT
CODE APPROVED SHEATHING (BY OTHERS)
DRYVIT BACKSTOP® NTAIR/WATER-RESISTIVE BARRIERBREATHER/BACKER BOARD (BY OTHERS)
DRYVIT AQUAFLASHâ SYSTEM LAPPED OVERMETAL FLASHING ONTO SHEATHING ANDONTO DRYVIT BACKSTOP NT
CASING BEAD WITH WEEPS (BY OTHERS)
RUBBERIZED ASPHALTIC WATERPROOFING (BY OTHERS)
CONTINUOUS METAL FLASHING (BY OTHERS)
25 MM (1 IN) MIN.
DRYVIT PRIMER AND FINISH
1. OTHER APPROVED SCRATCH ANDBROWN COATS MAY BE ACCEPTABLE.CONSULT DRYVIT SYSTEMS, INC. FORSPECIFICS.
NOTE:
2. PAPER BACKED LATH OR OTHER SLIP SHEETMAY BE REQUIRED OVER CERTAIN SUBSTRATES.
GALVANIZED SELF FURRING LATH (BY OTHERS) (NOTE 2)
The architecture, engineering, and design of the project using the
Dryvit products is the responsibility of the project's design
professional. All systems must comply with local building codes and
standards. This detail is for general information and guidance only
and Dryvit specifically disclaims any liability for the use of this detail
and for the architecture, design, engineering or workmanship of any
project. The project design professional determines, in its sole
discretion, whether this detail or a functionally equivalent detail is
best suited for the project. Use of a functionally equivalent detail does
not violate Dryvit's warranty. This detail is subject to change without
notice. Contact Dryvit to ensure you have the most recent version.
Commercial Cement Plaster 5™
©
Dryvit Systems, Inc. 1969
Issued: 10/2016
CCP-5 0.0.15
Termination at Soffit
DRYVIT COMMERCIAL CEMENT PLASTER BASEä, (NOTE 1)DRYVIT REINFORCING MESH EMBEDDED IN DRYVITGENESIS® OR GENESIS DM™ BASE COAT
BREATHER/BACKER BOARD (BY OTHERS)
SOFFIT (BY OTHERS)
13MM (1/2 IN) MIN.
CASING BEAD (BY OTHERS)
INSECT SCREEN (BY OTHERS)
CODE APPROVED SHEATHING (BY OTHERS)
DRYVIT BACKSTOP® NTAIR/WATER-RESISTIVE BARRIER
ROOFING ASSEMBLY (BY OTHERS)
DRYVIT PRIMER AND FINISH
1. OTHER APPROVED SCRATCH ANDBROWN COATS MAY BE ACCEPTABLE.CONSULT DRYVIT SYSTEMS, INC. FORSPECIFICS.
NOTE:
2. PAPER BACKED LATH OR OTHER SLIP SHEETMAY BE REQUIRED OVER CERTAIN SUBSTRATES.
GALVANIZED SELF FURRING LATH (BY OTHERS) (NOTE 2)
The architecture, engineering, and design of the project using the
Dryvit products is the responsibility of the project's design
professional. All systems must comply with local building codes and
standards. This detail is for general information and guidance only
and Dryvit specifically disclaims any liability for the use of this detail
and for the architecture, design, engineering or workmanship of any
project. The project design professional determines, in its sole
discretion, whether this detail or a functionally equivalent detail is
best suited for the project. Use of a functionally equivalent detail does
not violate Dryvit's warranty. This detail is subject to change without
notice. Contact Dryvit to ensure you have the most recent version.
Commercial Cement Plaster 5™
©
Dryvit Systems, Inc. 1969
Issued: 10/2016
CCP-5 0.0.16
Cement Plaster Control Joints
FRAMING (BY OTHERS)
CODE APPROVED SHEATHING (BY OTHERS)
PRESSURE TREATED WOODSTRAPPING (BY OTHERS)
CONTROL JOINT (BY OTHERS)DRYVIT COMMERCIAL CEMENT PLASTER BASEä,(NOTE1)DRYVIT REINFORCING MESH EMBEDDED INGENESIS® OR GENESIS DM™ BASE COAT
BREATHER BOARD (BY OTHERS)
DRYVIT BACKSTOP® NTAIR/WATER-RESISTIVE BARRIER
FRAMING (BY OTHERS)
CODE APPROVED SHEATHING (BY OTHERS)
PRESSURE TREATED WOODSTRAPPING (BY OTHERS)
CASING BEAD (BY OTHERS)
13MM (1/2 IN) MIN. BACKER RODAND SEALANT (BY OTHERS)
CASING BEAD (BY OTHERS)
DRYVIT COMMERCIAL CEMENT PLASTER BASEä,(NOTE 1)
DRYVIT REINFORCING MESH EMBEDDED INGENESIS® OR GENESIS DM™ BASE COAT
BREATHER/BACKER BOARD (BY OTHERS)
DRYVIT BACKSTOP® NTAIR/WATER-RESISTIVE BARRIER
DRYVIT PRIMER AND FINISH
DRYVIT PRIMER AND FINISH
1. OTHER APPROVED SCRATCH ANDBROWN COATS MAY BE ACCEPTABLE.CONSULT DRYVIT SYSTEMS, INC. FORSPECIFICS.
NOTE:
2. PAPER BACKED LATH OR OTHER SLIP SHEETMAY BE REQUIRED OVER CERTAIN SUBSTRATES.
GALVANIZED SELF FURRING LATH(BY OTHERS) (NOTE 2)
The architecture, engineering, and design of the project using the
Dryvit products is the responsibility of the project's design
professional. All systems must comply with local building codes and
standards. This detail is for general information and guidance only
and Dryvit specifically disclaims any liability for the use of this detail
and for the architecture, design, engineering or workmanship of any
project. The project design professional determines, in its sole
discretion, whether this detail or a functionally equivalent detail is
best suited for the project. Use of a functionally equivalent detail does
not violate Dryvit's warranty. This detail is subject to change without
notice. Contact Dryvit to ensure you have the most recent version.
Commercial Cement Plaster 5™
©
Dryvit Systems, Inc. 1969
Issued: 10/2016