COMMERCIAL CEMENT PLASTER 5 DS828 - Dryvit · dryvit commercial cement plaster base™ (note 1)...

18
COMMERCIAL CEMENT PLASTER 5 DS828 A Furred Rainscreen, Fiberglass Reinforced Portland Cement Plaster with Backstop® NT Air/Water-Resistive Barrier and Reinforced Surface Impact Layer Commercial Cement Plaster 5 Installation Details

Transcript of COMMERCIAL CEMENT PLASTER 5 DS828 - Dryvit · dryvit commercial cement plaster base™ (note 1)...

COMMERCIAL CEMENT PLASTER 5™

DS828

A Furred Rainscreen, Fiberglass Reinforced Portland Cement Plaster with Backstop® NT Air/Water-Resistive Barrier and Reinforced Surface Impact Layer

Commercial Cement Plaster 5 Installation Details

TABLE OF CONTENTS

Cement Plaster Control Joints

Termination at- Deck

Termination at- Parapet/ Wall Intersection

Termination at- Roof/ Wall Intersection

Termination at Roof/ Parapet

Termination at Dryer Vent

Termination at Storefront Window- Sill/ Jamb

Termination at Flanged Window- Sill/ Jamb

Floor Line Joint With Flashing

CCP 5 Cutaway

System Installation at Window

Termination at Railing Attachment

Termination at Soffit

DETAIL

CCP-5 0.0.14

CCP-5 0.0.16

CCP-5 0.0.15

CCP-5 0.0.08

CCP-5 0.0.09

CCP-5 0.0.12

CCP-5 0.0.13

CCP-5 0.0.11

CCP-5 0.0.07

CCP-5 0.0.10

CCP-5 0.0.04

PAGE

CCP-5 0.0.01

CCP-5 0.0.02

CCP-5 0.0.05

DRYVIT MAKES NO REPRESENTATION REGARDING CONFORMITY OFITS SUGGESTIONS TO MODEL BUILDING CODES, ENGINEERINGCRITERIA, SPECIFIC APPLICATIONS OR PROJECT LOCATIONS. ALLCOMPONENTS INDICATED IN ILLUSTRATIONS, AS WELL ASOTHERS THAT MAY BE REQUIRED FOR THE INTEGRITY OF THESYSTEM SHALL BE DESIGNED, DETAILED AND ENGINEERED BYREPRESENTATIVES OF THE ARCHITECT, OWNER OR CONTRACTORTO BE IN CONFORMANCE WITH MODEL CODES, ARCHITECTURALAND ENGINEERING REQUIREMENTS PERTAINING TO SPECIFICBUILDING PROJECTS.

DRYVIT MAKES NO WARRANTY, EXPRESSED OR IMPLIED, AS TOTHE ARCHITECTURAL DESIGN, ENGINEERING, OR WORKMANSHIP OFPROJECTS UTILIZING DRYVIT SYSTEMS OR PRODUCTS.

THE LIABILITIES OF DRYVIT SHALL BE AS STATED IN THEDRYVIT STANDARD WARRANTY. CONTACT DRYVIT FOR A FULLAND COMPLETE COPY OF THIS WARRANTY.

NOTE

Termination at Flanged Window- Head/ Jamb

CCP-5 0.0.06

Termination at Storefront Window- Head/ Jamb

Opening Preparation- Backstopâ NT/Aquaflashâ System

CCP-5 0.0.03

The architecture, engineering, and design of the project using the

Dryvit products is the responsibility of the project's design

professional. All systems must comply with local building codes and

standards. This detail is for general information and guidance only

and Dryvit specifically disclaims any liability for the use of this detail

and for the architecture, design, engineering or workmanship of any

project. The project design professional determines, in its sole

discretion, whether this detail or a functionally equivalent detail is

best suited for the project. Use of a functionally equivalent detail does

not violate Dryvit's warranty. This detail is subject to change without

notice. Contact Dryvit to ensure you have the most recent version.

Commercial Cement Plaster 5™

©

Dryvit Systems, Inc. 1969

Issued: 10/2016

CCP-5 0.0.01

CCP 5 Cutaway

CODE APPROVED SHEATHING (BY OTHERS)

PRESSURE TREATED WOODSTRAPPING OR EQUAL (BY OTHERS)

DRYVIT BACKSTOP® NTAIR/WATER-RESISTIVE BARRIER

BREATHER/BACKER BOARD (BY OTHERS)

GALVANIZED SELF-FURRING LATH (BY OTHERS)(NOTE 2)DRYVIT COMMERCIAL CEMENT PLASTER BASE™(NOTE 1)DRYVIT REINFORCING MESHEMBEDDED IN DRYVIT GENESIS® ORGENESIS DM™

DRYVIT PRIMER

DRYVIT FINISH

DRYVIT AQUAFLASH® SYSTEM

INSECT SCREEN (BY OTHERS)

CASING BEAD WITH WEEPS (BY OTHERS)

CONTINUOUS METAL FLASHING (BY OTHERS)

1. OTHER APPROVED SCRATCH ANDBROWN COATS MAY BE ACCEPTABLE.CONSULT DRYVIT SYSTEMS, INC. FORSPECIFICS.

NOTE:

2. PAPER BACKED LATH OR OTHER SLIP SHEETMAY BE REQUIRED OVER CERTAIN SUBSTRATES.

The architecture, engineering, and design of the project using the

Dryvit products is the responsibility of the project's design

professional. All systems must comply with local building codes and

standards. This detail is for general information and guidance only

and Dryvit specifically disclaims any liability for the use of this detail

and for the architecture, design, engineering or workmanship of any

project. The project design professional determines, in its sole

discretion, whether this detail or a functionally equivalent detail is

best suited for the project. Use of a functionally equivalent detail does

not violate Dryvit's warranty. This detail is subject to change without

notice. Contact Dryvit to ensure you have the most recent version.

Commercial Cement Plaster 5™

©

Dryvit Systems, Inc. 1969

Issued: 10/2016

CCP-5 0.0.02

Floor Line Joint With Flashing

GALVANIZED SELF FURRINGLATH (BY OTHERS) (NOTE 2)DRYVIT COMMERCIAL CEMENT PLASTER BASEä,(NOTE1)DRYVIT REINFORCING MESH EMBEDDED INGENESIS® OR GENESIS DM™, PRIMER AND FINISH

CODE APPROVED SHEATHING (BY OTHERS)

PRESSURE TREATED WOODSTRAPPING OR EQUAL (BY OTHERS)

DRYVIT BACKSTOP® NTAIR/WATER-RESISTIVE BARRIER

BREATHER/BACKER BOARD (BY OTHERS)

METAL FLASHING (BY OTHERS)

S-LOCK OR STANDING SEAM JOINT (BY OTHERS)

INSECT SCREEN (BY OTHERS)

DRYVIT AQUAFLASHâ SYSTEM

EXPANSION JOINT

SEALANT (BY OTHERS)

1. OTHER APPROVED SCRATCH ANDBROWN COATS MAY BE ACCEPTABLE.CONSULT DRYVIT SYSTEMS, INC. FORSPECIFICS.

NOTE:

2. PAPER BACKED LATH OR OTHER SLIP SHEETMAY BE REQUIRED OVER CERTAIN SUBSTRATES.

The architecture, engineering, and design of the project using the

Dryvit products is the responsibility of the project's design

professional. All systems must comply with local building codes and

standards. This detail is for general information and guidance only

and Dryvit specifically disclaims any liability for the use of this detail

and for the architecture, design, engineering or workmanship of any

project. The project design professional determines, in its sole

discretion, whether this detail or a functionally equivalent detail is

best suited for the project. Use of a functionally equivalent detail does

not violate Dryvit's warranty. This detail is subject to change without

notice. Contact Dryvit to ensure you have the most recent version.

Commercial Cement Plaster 5™

©

Dryvit Systems, Inc. 1969

Issued: 10/2016

CCP-5 0.0.03

INSTALL DIAGONAL STRIPOF DRYVIT AQUAFLASHMESH AND AQUAFLASHAT CORNERS(NOTES 1 AND 3)

APPLY DRYVIT AQUAFLASHSYSTEM (NOTES 1 AND 3)

DRYVIT BACKSTOP NTAIR/WATER-RESISTIVEBARRIER COATING

STEP #1 STEP #2

INSTALL DRYVIT AQUAFLASHSYSTEM AT JAMBS(NOTES 1 AND 3)

STEP #3 STEP #4

1. DRYVIT AQUAFLASH SHALL EXTEND TOINTERIOR FACE OF OPENING.REFER TO HEAD, SILL AND JAMBDETAILS FOR FLASHING INTEGRATION.

2.

3. INSTALL WINDOW UNIT AND ASSOCIATED FLASHINGS PER MANUFACTURER'S RECOMMENDATIONS, CODE REQUIREMENTS AND PROJECT DOCUMENTS.

NOTE:

INSTALL DRYVITAQUAFLASH SYSTEMAT HEADS(NOTES 1, 2, AND 3)

Opening Preparation-

Backstopâ NT/AquaFlash® System

The architecture, engineering, and design of the project using the

Dryvit products is the responsibility of the project's design

professional. All systems must comply with local building codes and

standards. This detail is for general information and guidance only

and Dryvit specifically disclaims any liability for the use of this detail

and for the architecture, design, engineering or workmanship of any

project. The project design professional determines, in its sole

discretion, whether this detail or a functionally equivalent detail is

best suited for the project. Use of a functionally equivalent detail does

not violate Dryvit's warranty. This detail is subject to change without

notice. Contact Dryvit to ensure you have the most recent version.

Commercial Cement Plaster 5™

©

Dryvit Systems, Inc. 1969

Issued: 10/2016

CCP-5 0.0.04

System Installation at Window

INSTALL WINDOW, SILL AND HEAD FLASHINGAND APPLY DRYVIT AQUAFLASHâ SYSTEMOVER HEAD FLASHING

INSTALL STRAPPING AND CEMENT PLASTERSYSTEM

The architecture, engineering, and design of the project using the

Dryvit products is the responsibility of the project's design

professional. All systems must comply with local building codes and

standards. This detail is for general information and guidance only

and Dryvit specifically disclaims any liability for the use of this detail

and for the architecture, design, engineering or workmanship of any

project. The project design professional determines, in its sole

discretion, whether this detail or a functionally equivalent detail is

best suited for the project. Use of a functionally equivalent detail does

not violate Dryvit's warranty. This detail is subject to change without

notice. Contact Dryvit to ensure you have the most recent version.

Commercial Cement Plaster 5™

©

Dryvit Systems, Inc. 1969

Issued: 10/2016

CCP-5 0.0.05

Termination at Flanged Window- Sill/Jamb

GALVANIZED SELF-FURRING LATH (BY OTHERS)(NOTE 2)

DRYVIT COMMERCIAL CEMENT PLASTER BASEä,(NOTE 1)DRYVIT REINFORCING MESH EMBEDDED IN DRYVITGENESIS® OR GENESIS DM™

CODE APPROVED SHEATHING (BY OTHERS)

DRYVIT BACKSTOP® NT AIR/WATER-RESISTIVEBARRIER

BREATHER/BACKER BOARD (BY OTHERS)

PRESSURE TREATED WOODSTRAPPING OR EQUAL (BY OTHERS)

DRYVIT AQUAFLASHâ SYSTEMCONTINUOUS WINDOW PERIMETER STRAPPING(BY OTHERS)

MIN. 13MM (1/2") SEALANT JOINT WITHCLOSED CELL BACKER ROD (BY OTHERS)WINDOW BASE FLASHING WITH END DAMS (BY OTHERS)

METAL ANGLE (BY OTHERS)

INTERMITTENT SHIM (BY OTHERS)

SEALANT (BY OTHERS)

DRYVIT PRIMER AND DRYVIT FINISH

1. OTHER APPROVED SCRATCH ANDBROWN COATS MAY BE ACCEPTABLE.CONSULT DRYVIT SYSTEMS, INC. FORSPECIFICS.

NOTE:

2. PAPER BACKED LATH OR OTHER SLIP SHEETMAY BE REQUIRED OVER CERTAIN SUBSTRATES.

The architecture, engineering, and design of the project using the

Dryvit products is the responsibility of the project's design

professional. All systems must comply with local building codes and

standards. This detail is for general information and guidance only

and Dryvit specifically disclaims any liability for the use of this detail

and for the architecture, design, engineering or workmanship of any

project. The project design professional determines, in its sole

discretion, whether this detail or a functionally equivalent detail is

best suited for the project. Use of a functionally equivalent detail does

not violate Dryvit's warranty. This detail is subject to change without

notice. Contact Dryvit to ensure you have the most recent version.

Commercial Cement Plaster 5™

©

Dryvit Systems, Inc. 1969

Issued: 10/2016

CCP-5 0.0.06

GALVANIZED SELF FURRING LATH (BY OTHERS)

DRYVIT COMMERCIAL CEMENT PLASTER BASEä,(NOTE 1)DRYVIT REINFORCING MESH EMBEDDED IN DRYVITGENESIS® OR GENESIS DM™ BASE COAT

CODE APPROVED SHEATHING (BY OTHERS)

DRYVIT BACKSTOP® NTAIR/WATER-RESISTIVE BARRIER

BREATHER/BACKER BOARD (BY OTHERS)

PRESSURE TREATED WOODSTRAPPING OR EQUAL (BY OTHERS)

DRYVIT AQUAFLASHâ SYSTEM AT JAMBS

CONTINUOUS WINDOW PERIMETER STRAPPING (BY OTHERS)

MIN. 13MM (1/2 IN) SEALANT JOINT WITHCLOSED CELL BACKER ROD (BY OTHERS)

INSECT SCREEN (BY OTHERS)

WINDOW HEAD FLASHING WITH END DAMS (BY OTHERS)

DRYVIT PRIMER AND DRYVIT FINISH

1. OTHER APPROVED SCRATCH ANDBROWN COATS MAY BE ACCEPTABLE.CONSULT DRYVIT SYSTEMS, INC. FORSPECIFICS.

NOTE:The architecture, engineering, and design of the project using the

Dryvit products is the responsibility of the project's design

professional. All systems must comply with local building codes and

standards. This detail is for general information and guidance only

and Dryvit specifically disclaims any liability for the use of this detail

and for the architecture, design, engineering or workmanship of any

project. The project design professional determines, in its sole

discretion, whether this detail or a functionally equivalent detail is

best suited for the project. Use of a functionally equivalent detail does

not violate Dryvit's warranty. This detail is subject to change without

notice. Contact Dryvit to ensure you have the most recent version.

Commercial Cement Plaster 5™

©

Dryvit Systems, Inc. 1969

Issued: 10/2016

Termination at

Flanged Window-Head/Jamb

CCP-5 0.0.07

Termination at Storefront Window-Sill/Jamb

GALVANIZED SELF FURRING LATH (BY OTHERS) (NOTE 2)

DRYVIT COMMERCIAL CEMENT PLASTER BASEä (NOTE 1)DRYVIT REINFORCING MESH EMBEDDED IN DRYVITGENESIS® OR GENESIS DM™ BASE COAT

CODE APPROVED SHEATHING (BY OTHERS)

DRYVIT BACKSTOP® NTAIR/WATER-RESISTIVE BARRIER

BREATHER/BACKER BOARD (BY OTHERS)

PRESSURE TREATED WOODSTRAPPING OR EQUAL (BY OTHERS)

DRYVIT AQUAFLASHâ SYSTEM AT JAMBS

MIN. 13MM (1/2 IN) SEALANT JOINT WITHCLOSED CELL BACKER ROD (BY OTHERS)

METAL PAN FLASHING (BY OTHERS)

INTERMITTENT SHIM (BY OTHERS)

CONTINUOUS WINDOW PERIMETER STRAPPING (BY OTHERS)

DRYVIT PRIMER AND FINISH

1. OTHER APPROVED SCRATCH ANDBROWN COATS MAY BE ACCEPTABLE.CONSULT DRYVIT SYSTEMS, INC. FORSPECIFICS.

NOTE:

2. PAPER BACKED LATH OR OTHER SLIP SHEETMAY BE REQUIRED OVER CERTAIN SUBSTRATES.

The architecture, engineering, and design of the project using the

Dryvit products is the responsibility of the project's design

professional. All systems must comply with local building codes and

standards. This detail is for general information and guidance only

and Dryvit specifically disclaims any liability for the use of this detail

and for the architecture, design, engineering or workmanship of any

project. The project design professional determines, in its sole

discretion, whether this detail or a functionally equivalent detail is

best suited for the project. Use of a functionally equivalent detail does

not violate Dryvit's warranty. This detail is subject to change without

notice. Contact Dryvit to ensure you have the most recent version.

Commercial Cement Plaster 5™

©

Dryvit Systems, Inc. 1969

Issued: 10/2016

CCP-5 0.0.08

GALVANIZED SELF FURRING LATH (BY OTHERS) (NOTE 2)

DRYVIT COMMERCIAL CEMENT PLASTER BASEä (NOTE 1)DRYVIT REINFORCING MESH EMBEDDED IN DRYVITGENESIS® OR GENESIS DM™ BASE COAT

CODE APPROVED SHEATHING (BY OTHERS)

DRYVIT BACKSTOP® NTAIR/WATER-RESISTIVE BARRIER

BREATHER/BACKER BOARD (BY OTHERS)

PRESSURE TREATED WOODSTRAPPING OR EQUAL (BY OTHERS)

DRYVIT FLASHING TAPE AT JAMBS

CONTINUOUS WINDOW PERIMETER STRAPPING (BY OTHERS)

MIN. 13MM (1/2 IN) SEALANT JOINT WITHCLOSED CELL BACKER ROD (BY OTHERS)

INSECT SCREEN (BY OTHERS)

WINDOW HEAD FLASHING WITH END DAMS (BY OTHERS)

DRYVIT PRIMER AND FINISH

1. OTHER APPROVED SCRATCH ANDBROWN COATS MAY BE ACCEPTABLE.CONSULT DRYVIT SYSTEMS, INC. FORSPECIFICS.

NOTE:

2. PAPER BACKED LATH OR OTHER SLIP SHEETMAY BE REQUIRED OVER CERTAIN SUBSTRATES.

The architecture, engineering, and design of the project using the

Dryvit products is the responsibility of the project's design

professional. All systems must comply with local building codes and

standards. This detail is for general information and guidance only

and Dryvit specifically disclaims any liability for the use of this detail

and for the architecture, design, engineering or workmanship of any

project. The project design professional determines, in its sole

discretion, whether this detail or a functionally equivalent detail is

best suited for the project. Use of a functionally equivalent detail does

not violate Dryvit's warranty. This detail is subject to change without

notice. Contact Dryvit to ensure you have the most recent version.

Commercial Cement Plaster 5™

©

Dryvit Systems, Inc. 1969

Issued: 10/2016

Termination at

Storefront Window-Head/Jamb

CCP-5 0.0.09

Termination at Railing Attachment

GALVANIZED SELF-FURRING LATH (BY OTHERS)(NOTE 2)DRYVIT COMMERCIAL CEMENT PLASTER BASEä(NOTE 1)DRYVIT REINFORCING MESH EMBEDDED IN DRYVITGENESIS® OR GENESIS DM™ BASE COAT

CODE APPROVED SHEATHING (BY OTHERS)

DRYVIT BACKSTOP® NTAIR/WATER-RESISTIVE BARRIER

BREATHER/BACKER BOARD (BY OTHERS)

PRESSURE TREATED WOODSTRAPPING OR EQUAL (BY OTHERS)

DRYVIT AQUAFLASHâ SYSTEM

MIN. 13MM (1/2 IN) SEALANT JOINT WITHCLOSED CELL BACKER ROD (BY OTHERS)

BLOCKING SLOPED SIDEWISE (BY OTHERS)

SLEEVE, STRUCTURALBACKING (BY OTHERS)

RAILING (BY OTHERS)

DRYVIT PRIMER AND FINISH

1. OTHER APPROVED SCRATCH ANDBROWN COATS MAY BE ACCEPTABLE.CONSULT DRYVIT SYSTEMS, INC. FORSPECIFICS.

NOTE:

2. PAPER BACKED LATH OR OTHER SLIP SHEETMAY BE REQUIRED OVER CERTAIN SUBSTRATES.

©

The architecture, engineering, and design of the project using the

Dryvit products is the responsibility of the project's design

professional. All systems must comply with local building codes and

standards. This detail is for general information and guidance only

and Dryvit specifically disclaims any liability for the use of this detail

and for the architecture, design, engineering or workmanship of any

project. The project design professional determines, in its sole

discretion, whether this detail or a functionally equivalent detail is

best suited for the project. Use of a functionally equivalent detail does

not violate Dryvit's warranty. This detail is subject to change without

notice. Contact Dryvit to ensure you have the most recent version.

Commercial Cement Plaster 5™

©

Dryvit Systems, Inc. 1969

Issued: 10/2016

CCP-5 0.0.10

Termination at Dryer Vent

1. OTHER APPROVED SCRATCH ANDBROWN COATS MAY BE ACCEPTABLE.CONSULT DRYVIT SYSTEMS, INC. FOR

SPECIFICS.

NOTE:

2. PAPER BACKED LATH OR OTHER SLIP SHEETMAY BE REQUIRED OVER CERTAIN SUBSTRATES.

The architecture, engineering, and design of the project using the

Dryvit products is the responsibility of the project's design

professional. All systems must comply with local building codes and

standards. This detail is for general information and guidance only

and Dryvit specifically disclaims any liability for the use of this detail

and for the architecture, design, engineering or workmanship of any

project. The project design professional determines, in its sole

discretion, whether this detail or a functionally equivalent detail is

best suited for the project. Use of a functionally equivalent detail does

not violate Dryvit's warranty. This detail is subject to change without

notice. Contact Dryvit to ensure you have the most recent version.

Commercial Cement Plaster 5™

©

Dryvit Systems, Inc. 1969

Issued: 10/2016

GALVANIZED SELF FURRING LATH (BY OTHERS) (NOTE 2)

DRYVIT COMMERCIAL CEMENT PLASTER BASEä(NOTE1)DRYVIT REINFORCING MESH EMBEDDED INGENESIS® OR GENESIS DM BASE COAT

CODE APPROVED SHEATHING (BY OTHERS)

DRYVIT BACKSTOP® NTAIR/WATER-RESISTIVE BARRIER

BREATHER/BACKER BOARD (BY OTHERS)

PRESSURE TREATED WOODSTRAPPING OR EQUAL (BY OTHERS)

DRYVIT AQUAFLASHâ SYSTEM OVER VENT FLANGE

MIN. 13MM (1/2 IN) SEALANT JOINT WITHCLOSED CELL BACKER ROD (BY OTHERS)INSECT SCREEN (BY OTHERS)

DRYER VENT HOOD, SLOPED AT TOP (BY OTHERS)

DRYVIT PRIMER AND FINISH

CCP-5 0.0.11

Termination at Roof/Parapet

CASING BEAD (BY OTHERS)

65MM (2 1/2 IN) MIN.

200MM (8 IN) MIN. FROM ROOF LINE

INSECT SCREEN (BY OTHERS)

CODE APPROVED SHEATHING (BY OTHERS)

DRYVIT BACKSTOP® NTAIR/WATER-RESISTIVE BARRIERBREATHER/BACKER BOARD (BY OTHERS)

DRYVIT COMMERCIAL CEMENT PLASTER BASEä(NOTE 1)DRYVIT REINFORCING MESH EMBEDDED INDRYVIT GENESIS® OR GENESIS DM™ BASE COAT

METAL CAP FLASHING (BY OTHERS)

PARAPET FLASHING MEMBRANE (BY OTHERS)

PRESSURE TREATED BLOCKING (BY OTHERS)

DRYVIT BACKSTOP® NTAIR/WATER-RESISTIVE BARRIER

DRYVIT AQUAFLASHâ SYSTEM

BREATHER/BACKER BOARD (BY OTHERS)

ROOFING MEMBRANE (BY OTHERS)

SEALANT UNDER UPTURNED LEG (BY OTHERS)

13MM (1/2 IN) MIN. SEALANT JOINT (BY OTHERS)

DRYVIT PRIMER AND FINISH

DRYVIT COMMERCIAL CEMENT PLASTER BASEä,(NOTE 1)

DRYVIT REINFORCING MESH EMBEDDED INDRYVIT GENESIS® OR GENESIS DM™, BASECOAT

DRYVIT PRIMER AND FINISH

1. OTHER APPROVED SCRATCH ANDBROWN COATS MAY BE ACCEPTABLE.CONSULT DRYVIT SYSTEMS, INC. FORSPECIFICS.

NOTE:

2. PAPER BACKED LATH OR OTHER SLIP SHEETMAY BE REQUIRED OVER CERTAIN SUBSTRATES.

GALVANIZED SELF FURRING LATH (BY OTHERS) (NOTE 2)

The architecture, engineering, and design of the project using the

Dryvit products is the responsibility of the project's design

professional. All systems must comply with local building codes and

standards. This detail is for general information and guidance only

and Dryvit specifically disclaims any liability for the use of this detail

and for the architecture, design, engineering or workmanship of any

project. The project design professional determines, in its sole

discretion, whether this detail or a functionally equivalent detail is

best suited for the project. Use of a functionally equivalent detail does

not violate Dryvit's warranty. This detail is subject to change without

notice. Contact Dryvit to ensure you have the most recent version.

Commercial Cement Plaster 5™

©

Dryvit Systems, Inc. 1969

Issued: 10/2016

CCP-5 0.0.12

Termination at Roof/Wall Intersection

GALVANIZED SELF FURRING LATH (BY OTHERS)(NOTE 2)DRYVIT COMMERCIAL CEMENT PLASTER BASEä(NOTE1)DRYVIT REINFORCING MESH EMBEDDED IN DRYVITGENESIS® OR GENESIS DM™ BASE COAT

CODE APPROVED SHEATHING (BY OTHERS)

DRYVIT BACKSTOP® NTAIR/WATER-RESISTIVE BARRIER

BREATHER/BACKER BOARD (BY OTHERS)

PRESSURE TREATED WOODSTRAPPING OR EQUAL (BY OTHERS)

DRYVIT AQUAFLASHâ SYSTEM

STEP FLASHING (BY OTHERS)

DIVERTER FLASHING (BY OTHERS)

50MM (2 IN) MIN.

MIN. 13MM (1/2 IN) SEALANT (BY OTHERS)

DRYVIT PRIMER AND FINISH

1. OTHER APPROVED SCRATCH ANDBROWN COATS MAY BE ACCEPTABLE.CONSULT DRYVIT SYSTEMS, INC. FORSPECIFICS.

NOTE:

2. PAPER BACKED LATH OR OTHER SLIP SHEETMAY BE REQUIRED OVER CERTAIN SUBSTRATES.

The architecture, engineering, and design of the project using the

Dryvit products is the responsibility of the project's design

professional. All systems must comply with local building codes and

standards. This detail is for general information and guidance only

and Dryvit specifically disclaims any liability for the use of this detail

and for the architecture, design, engineering or workmanship of any

project. The project design professional determines, in its sole

discretion, whether this detail or a functionally equivalent detail is

best suited for the project. Use of a functionally equivalent detail does

not violate Dryvit's warranty. This detail is subject to change without

notice. Contact Dryvit to ensure you have the most recent version.

Commercial Cement Plaster 5™

©

Dryvit Systems, Inc. 1969

Issued: 10/2016

CCP-5 0.0.13

Termination at Parapet/Wall Intersection

GALVANIZED SELF FURRING LATH (BY OTHERS (NOTE 2))DRYVIT COMMERCIAL CEMENT PLASTER BASEä(NOTE1)DRYVIT REINFORCING MESH EMBEDDED IN DRYVITGENESIS® OR GENESIS DM™ BASE COAT

CODE APPROVED SHEATHING (BY OTHERS)

DRYVIT BACKSTOP® NTAIR/WATER-RESISTIVE BARRIER

BREATHER/BACKER BOARD (BY OTHERS)

PRESSURE TREATED WOODSTRAPPING OR EQUAL (BY OTHERS)

SADDLE FLASHING WITH SEALANTUNDER UP TURNED LEG (BY OTHERS)

DRYVIT AQUAFLASH® SYSTEM LAPPED OVERMETAL SADDLE FLASHING UP TURNED LEG

BLOCKING SLOPED FOR DRAINAGE (BY OTHERS)

RETAINING CLIP (BY OTHERS)

PARAPET MEMBRANE (BY OTHERS)

DRYVIT PRIMER AND FINISH

1. OTHER APPROVED SCRATCH ANDBROWN COATS MAY BE ACCEPTABLE.CONSULT DRYVIT SYSTEMS, INC. FORSPECIFICS.

NOTE:

2. PAPER BACKED LATH OR OTHER SLIP SHEETMAY BE REQUIRED OVER CERTAIN SUBSTRATES.

The architecture, engineering, and design of the project using the

Dryvit products is the responsibility of the project's design

professional. All systems must comply with local building codes and

standards. This detail is for general information and guidance only

and Dryvit specifically disclaims any liability for the use of this detail

and for the architecture, design, engineering or workmanship of any

project. The project design professional determines, in its sole

discretion, whether this detail or a functionally equivalent detail is

best suited for the project. Use of a functionally equivalent detail does

not violate Dryvit's warranty. This detail is subject to change without

notice. Contact Dryvit to ensure you have the most recent version.

Commercial Cement Plaster 5™

©

Dryvit Systems, Inc. 1969

Issued: 10/2016

CCP-5 0.0.14

Termination at Deck

INSECT SCREEN (BY OTHERS)

DRYVIT COMMERCIAL CEMENT PLASTER BASEä (NOTE 1)DRYVIT REINFORCING MESH EMBEDDED IN DRYVITGENESIS® OR GENESIS DM™ BASE COAT

CODE APPROVED SHEATHING (BY OTHERS)

DRYVIT BACKSTOP® NTAIR/WATER-RESISTIVE BARRIERBREATHER/BACKER BOARD (BY OTHERS)

DRYVIT AQUAFLASHâ SYSTEM LAPPED OVERMETAL FLASHING ONTO SHEATHING ANDONTO DRYVIT BACKSTOP NT

CASING BEAD WITH WEEPS (BY OTHERS)

RUBBERIZED ASPHALTIC WATERPROOFING (BY OTHERS)

CONTINUOUS METAL FLASHING (BY OTHERS)

25 MM (1 IN) MIN.

DRYVIT PRIMER AND FINISH

1. OTHER APPROVED SCRATCH ANDBROWN COATS MAY BE ACCEPTABLE.CONSULT DRYVIT SYSTEMS, INC. FORSPECIFICS.

NOTE:

2. PAPER BACKED LATH OR OTHER SLIP SHEETMAY BE REQUIRED OVER CERTAIN SUBSTRATES.

GALVANIZED SELF FURRING LATH (BY OTHERS) (NOTE 2)

The architecture, engineering, and design of the project using the

Dryvit products is the responsibility of the project's design

professional. All systems must comply with local building codes and

standards. This detail is for general information and guidance only

and Dryvit specifically disclaims any liability for the use of this detail

and for the architecture, design, engineering or workmanship of any

project. The project design professional determines, in its sole

discretion, whether this detail or a functionally equivalent detail is

best suited for the project. Use of a functionally equivalent detail does

not violate Dryvit's warranty. This detail is subject to change without

notice. Contact Dryvit to ensure you have the most recent version.

Commercial Cement Plaster 5™

©

Dryvit Systems, Inc. 1969

Issued: 10/2016

CCP-5 0.0.15

Termination at Soffit

DRYVIT COMMERCIAL CEMENT PLASTER BASEä, (NOTE 1)DRYVIT REINFORCING MESH EMBEDDED IN DRYVITGENESIS® OR GENESIS DM™ BASE COAT

BREATHER/BACKER BOARD (BY OTHERS)

SOFFIT (BY OTHERS)

13MM (1/2 IN) MIN.

CASING BEAD (BY OTHERS)

INSECT SCREEN (BY OTHERS)

CODE APPROVED SHEATHING (BY OTHERS)

DRYVIT BACKSTOP® NTAIR/WATER-RESISTIVE BARRIER

ROOFING ASSEMBLY (BY OTHERS)

DRYVIT PRIMER AND FINISH

1. OTHER APPROVED SCRATCH ANDBROWN COATS MAY BE ACCEPTABLE.CONSULT DRYVIT SYSTEMS, INC. FORSPECIFICS.

NOTE:

2. PAPER BACKED LATH OR OTHER SLIP SHEETMAY BE REQUIRED OVER CERTAIN SUBSTRATES.

GALVANIZED SELF FURRING LATH (BY OTHERS) (NOTE 2)

The architecture, engineering, and design of the project using the

Dryvit products is the responsibility of the project's design

professional. All systems must comply with local building codes and

standards. This detail is for general information and guidance only

and Dryvit specifically disclaims any liability for the use of this detail

and for the architecture, design, engineering or workmanship of any

project. The project design professional determines, in its sole

discretion, whether this detail or a functionally equivalent detail is

best suited for the project. Use of a functionally equivalent detail does

not violate Dryvit's warranty. This detail is subject to change without

notice. Contact Dryvit to ensure you have the most recent version.

Commercial Cement Plaster 5™

©

Dryvit Systems, Inc. 1969

Issued: 10/2016

CCP-5 0.0.16

Cement Plaster Control Joints

FRAMING (BY OTHERS)

CODE APPROVED SHEATHING (BY OTHERS)

PRESSURE TREATED WOODSTRAPPING (BY OTHERS)

CONTROL JOINT (BY OTHERS)DRYVIT COMMERCIAL CEMENT PLASTER BASEä,(NOTE1)DRYVIT REINFORCING MESH EMBEDDED INGENESIS® OR GENESIS DM™ BASE COAT

BREATHER BOARD (BY OTHERS)

DRYVIT BACKSTOP® NTAIR/WATER-RESISTIVE BARRIER

FRAMING (BY OTHERS)

CODE APPROVED SHEATHING (BY OTHERS)

PRESSURE TREATED WOODSTRAPPING (BY OTHERS)

CASING BEAD (BY OTHERS)

13MM (1/2 IN) MIN. BACKER RODAND SEALANT (BY OTHERS)

CASING BEAD (BY OTHERS)

DRYVIT COMMERCIAL CEMENT PLASTER BASEä,(NOTE 1)

DRYVIT REINFORCING MESH EMBEDDED INGENESIS® OR GENESIS DM™ BASE COAT

BREATHER/BACKER BOARD (BY OTHERS)

DRYVIT BACKSTOP® NTAIR/WATER-RESISTIVE BARRIER

DRYVIT PRIMER AND FINISH

DRYVIT PRIMER AND FINISH

1. OTHER APPROVED SCRATCH ANDBROWN COATS MAY BE ACCEPTABLE.CONSULT DRYVIT SYSTEMS, INC. FORSPECIFICS.

NOTE:

2. PAPER BACKED LATH OR OTHER SLIP SHEETMAY BE REQUIRED OVER CERTAIN SUBSTRATES.

GALVANIZED SELF FURRING LATH(BY OTHERS) (NOTE 2)

The architecture, engineering, and design of the project using the

Dryvit products is the responsibility of the project's design

professional. All systems must comply with local building codes and

standards. This detail is for general information and guidance only

and Dryvit specifically disclaims any liability for the use of this detail

and for the architecture, design, engineering or workmanship of any

project. The project design professional determines, in its sole

discretion, whether this detail or a functionally equivalent detail is

best suited for the project. Use of a functionally equivalent detail does

not violate Dryvit's warranty. This detail is subject to change without

notice. Contact Dryvit to ensure you have the most recent version.

Commercial Cement Plaster 5™

©

Dryvit Systems, Inc. 1969

Issued: 10/2016