COMBUSTION ENGINEERING FDC BURNERS DATA … · - Final treatment ovens for paint drying and curing...

2
MODEL HEAT INPUT RANGE TYPICAL GAS CONNECTION SIZE FD5C 9 - 117 kW ¾” BSP FD5C 9 - 220 kW 1” BSP FD10C 13 - 350 kW 1” BSP FD10C 13 - 440 kW 1½” BSP FD15C 18 - 660 kW 1½” BSP FD20C 25 - 880 kW 2” BSP FD25C 45 - 1150 kW 2” BSP FD30C 45 - 1350 kW 2” BSP FD35C 45 - 1550 kW 2” BSP TYPICAL APPLICATIONS • Product finishing - Pre-treatment dryers - Final treatment ovens for paint drying and curing - Conveyor and batch ovens • Textile and fabric dryers • Rotary moulding machines • Food processing • Powder and grain dryers PRODUCT DESCRIPTION FDC burners comprise a burner windbox, combustion air fan, a manual sliding damper fitted between the combustion air fan and the air entry flange on the burner windbox, a compact monoblock train and gas burner controls mounted within a control panel. Standard control items include a burner controller, ignition transformer and differential air pressure switch. Two 3-way air valves perform safety checks on the air pressure switch in both open and closed modes each time the burner fires, allowing the independent operation of the combustion air fan in conjunction with oven / dryer main recirculation fans. FDC BURNERS DATA Lanemark FDC series packaged burners are designed to offer low cost, high turndown (gas only) control for process air heating applications in convection ovens and dryers. FDC series burners are particularly suited to direct fired applications and can be mounted directly on to the wall of a dryer, oven or process air heating duct to operate either in line with or at 90˚to the process airflow. FDC series burners produce short flame profiles – an important requirement for industrial oven design. Combustion air and gas is progressively mixed within the internal burner cone assembly, guaranteeing stable combustion over a wide range of oven / dryer process airflows. COMBUSTION ENGINEERING Vertical arrangement Horizontal arrangement

Transcript of COMBUSTION ENGINEERING FDC BURNERS DATA … · - Final treatment ovens for paint drying and curing...

Page 1: COMBUSTION ENGINEERING FDC BURNERS DATA … · - Final treatment ovens for paint drying and curing - Conveyor and batch ovens • Textile and fabric dryers • Rotary moulding machines

MODEL HEAT INPUT RANGETYPICAL GAS CONNECTION SIZE

FD5C 9 - 117 kW ¾” BSP

FD5C 9 - 220 kW 1” BSP

FD10C 13 - 350 kW 1” BSP

FD10C 13 - 440 kW 1½” BSP

FD15C 18 - 660 kW 1½” BSP

FD20C 25 - 880 kW 2” BSP

FD25C 45 - 1150 kW 2” BSP

FD30C 45 - 1350 kW 2” BSP

FD35C 45 - 1550 kW 2” BSP

TYPICAL APPLICATIONS• Product finishing

- Pre-treatment dryers

- Final treatment ovens for paint drying and curing

- Conveyor and batch ovens

• Textile and fabric dryers

• Rotary moulding machines

• Food processing

• Powder and grain dryers

PRODUCT DESCRIPTIONFDC burners comprise a burner windbox, combustion air fan, a manual sliding damper fitted between the combustion air fan and the air entry flange on the burner windbox, a compact monoblock train and gas burner controls mounted within a control panel.

Standard control items include a burner controller, ignition transformer and differential air pressure switch. Two 3-way air valves perform safety checks on the air pressure switch in both open and closed modes each time the burner fires, allowing the independent operation of the combustion air fan in conjunction with oven / dryer main recirculation fans.

FDC BURNERS DATALanemark FDC series packaged burners are designed to offer low cost, high turndown (gas only) control for process air heating applications in convection ovens and dryers.

FDC series burners are particularly suited to direct fired applications and can be mounted directly on to the wall of a dryer, oven or process air heating duct to operate either in line with or at 90˚to the process airflow.

FDC series burners produce short flame profiles – an important requirement for industrial oven design. Combustion air and gas is progressively mixed within the internal burner cone assembly, guaranteeing stable combustion over a wide range of oven / dryer process airflows.

C O M B U S T I O N E N G I N E E R I N G

Vertical arrangement

Horizontal arrangement

Lanmark Technical Data Sheets 2018 v3.indd 5 19/06/2018 07:34

Page 2: COMBUSTION ENGINEERING FDC BURNERS DATA … · - Final treatment ovens for paint drying and curing - Conveyor and batch ovens • Textile and fabric dryers • Rotary moulding machines

All Lanemark burners benefit from Lanemark’s BurnerCare customer support. BurnerCare services can include burner system installation, commissioning / start-up, system training, regular servicing and the supply of spare parts. BurnerCare can provide a service agreement plan incorporating a rapid response facility individually designed to ensure the continued, reliable operation of Lanemark equipment worldwide.

FDC BURNERS

SPECIFICATIONS STANDARD EQUIPMENT OPTIONS

Fuels Natural gas Propane

Control voltages 230 V / 1ph / 50 Hz 110 V / 1ph / 50-60 Hz

Combustion air fan electrical supplies 400 V / 3ph / 50 Hz 230 V / 1ph / 50 Hz

Flame sensing Flame electrode UV scanner

Heat output control On / off ; High / low. High / low / ultra low Modulating (gas only) 4-20 mA / 0-10V DC / 3 Wire Direct Drive

Lanemark FDC burners are pre-wired / tested prior to despatch and conform with relevant sections of European Standard EN 746 Part 2 or NFPA 86 for US applications.

MODEL GAS TRAIN

A B C D E1 E2 F1 F2 G1 G2 H J K L DIA

M DIA

N PCD

P Q DIA

R DIA

S

FD5 G96 528 423 193 207 398 506 485 671 416 416 101 156 294 150 175 225 M8x50 195 160 360

FD5 VCD1 528 423 193 207 571 571 426 748 416 439 101 156 294 150 175 225 M8x50 195 160 360

FD10 VCD1 548 452 193 220 577 577 456 591 450 482 118 185 336 183 214 268 M8x50 240 200 410

FD10 VCD2 548 452 193 220 600 600 568 692 450 482 118 185 336 183 214 268 M8x50 240 200 410

FD15 VCD2 581 507 217 218 610 610 571 685 514 577 150 253 430 232 270 330 M8x50 295 250 460

FD20 VCD3 621 562 199 219 640 640 684 842 560 560 177 315 473 267 315 380 M10x50 335 290 510

FD25 VCD3 621 743 199 346 640 640 684 842 560 560 158 325 473 267 315 380 M10x50 335 290 510

FD30 VCD3 646 706 233 375 667 667 705 853 637 695 190 359 550 307 370 445 M10x50 390 330 585

FD35 VCD3 646 795 233 417 667 667 705 853 637 695 185 359 550 307 370 445 M10x50 390 330 585

1

1

2

2

3

3

4

4

5

5

6

6

7

7

8

8

A A

B B

C C

D D

E E

F F

DIMENSIONS ARE INmm AND DEGREES

TOLERANCE AS STATEDOR ±

DRAWING SCALE

PAPER SIZE

ISSUE DESCRIPTION

THIS DRAWING IS THE COPYRIGHT OF'LANEMARK COMBUSTION ENGINEERING Ltd'AND MUST NOT BE COPIED OR RE-ISSUED

WITHOUT PERMISSION.

WHITACRE ROAD, NUNEATON, WARWICKSHIRE, CV11 6BWTel: +44 (0)2476 352000 Fax: +44 (0)2476 341166E-Mail: [email protected] Website: www.lanemark.com

ANEMARCOMBUSTION ENGINEERING LTDL K

DRAWN BY:

DATE:

CHECKED BY:

DATE:

ISSUE: DRAWING No:

PROJECT No:

TITLE:

Do NotScale Print

PROJECTION This is a angle drawing

SHEET OF

DRAWING No:

BYDATE

FD-C MK6 HIGH / LOW & MOD GAS

40 906

AJS

16/08/2016

01

40 9

06

0203

FIRST - COMPILATION OF 40827 & 40829

040506070809

16/08/2016 AJS

ARL

16/08/2016

1A2 1 1

1st

DIMENSIONS FOR MKTGGENERAL ARRANGEMENT

150

SERV

ICE

CLEA

RANC

E

600SERVICE CLEARANCE

'Q' DIA 'R' DIA

8 X 'P' FIXING STUDSOR OTHER SUITABLE

FIXING METHOD ON 'N' PCD

8 X 'P' FIXING STUDSOR OTHER SUITABLE

FIXING METHOD ON 'N' PCD

'N' PCD

'N' PCD

OVEN MOUNTING DETAILS

OVEN CUT OUT DETAILFOR COMBUSTION TUBE

OVEN CUT OUT DETAILFOR FLAME TUBE

MODEL GAS TRAIN A B C D E1 E2 F1 F2 G1 G2 H J K L DIA M DIA N PCD P Q DIA R DIA SFD5 G96 528 423 193 207 398 506 485 671 416 416 101 156 294 150 175 225 M8x50 195 160 360FD5 VCD1 528 423 193 207 571 571 426 748 416 439 101 156 294 150 175 225 M8x50 195 160 360FD10 VCD1 548 452 193 220 577 577 456 591 450 482 118 185 336 183 214 268 M8x50 240 200 410FD10 VCD2 548 452 193 220 600 600 568 692 450 482 118 185 336 183 214 268 M8x50 240 200 410FD15 VCD2 581 507 217 218 610 610 571 685 514 577 150 253 430 232 270 330 M8x50 295 250 460

FD20 VCD3 621 562 199 219 640 640 684 842 560 560 177 315 473 267 315 380 M10x50 335 290 510FD25 VCD3 621 743 199 346 640 640 684 842 560 560 158 325 473 267 315 380 M10x50 335 290 510FD30 VCD3 646 706 233 375 667 667 705 853 637 695 190 359 550 307 370 445 M10x50 390 330 585FD35 VCD3 646 795 233 417 667 667 705 853 637 695 185 359 550 307 370 445 M10x50 390 330 585

'A'

'B'

'C' 'D'

'E1' = HIGH / LOW

'F1'

REF

= HIGH

/ L

OW

'G1' = HIGH / LOW

'H'

'K'

'J'

'L' DIA

'M' DIA

216FLAME TUBE

'S'COMBUSTION TUBE

STANDARD / MINIMUM LENGTH(OPTIONAL SUPPLY)

n/a

'E2' = MODULATING GAS

'F2' R

EF =

MOD

ULAT

ING

GAS

'G2' = MODULATING GAS

POSITION OF MODULATING MOTOR ASSY (ADDITION TO GAS TRAIN)

All illustrations are for guidance only. For reasons of continuous development, Lanemark Combustion Engineering Limited reserves the right to alter specifications without prior notice.

Registered Address: Lanemark House, Whitacre Road, Nuneaton, Warwickshire, UK, CV11 6BW T: +44 (0) 24 7635 2000 F: +44 (0) 24 7634 1166 E: [email protected] W: www.lanemark.comCompany Registration No. 1561589. VAT No. GB 307 5790 48. Place of Registration: England and Wales. Directors: P.R. Collier, J.S. Foster, A.E. Thompson.

C O M B U S T I O N E N G I N E E R I N G

Dimensions (mm, except where shown)

Lanmark Technical Data Sheets 2018 v3.indd 6 19/06/2018 07:34