Since 1970 Comat AG has been the competent supplier of equipment and systems for industrial automation. In 1996 the company introduced a Quality Management System certified in accordance with ISO norm 9001.
As a successful manufacturer in the industrial electronics field, Comat enjoys an out-standing world-wide reputation with its first-class range of industrial-, time delay- and monitoring relays.A variety of international patents underline the high degree of innovation.
The subsidiary companies in Spain, Releco S.A. and in China, Comat (Tianjin) Industrial Electronic Co., Ltd. are members of the Comat group.
All our own products are continually being re-designed and kept up to date in accord-ance with the latest state-of–the-art technology. As always, Comat manufactures all its own products at its headquarters in Worb, Switzerland. The in-house development department enables us to react swiftly and flexibly to changing customer requirements. In addition, customer-specific developments can also be realized in the usual business sectors.
Starting from its position as the Swiss home market leader, Comat exports its products to 43 agencies in the most industrial countries, supported by a competent in-house team of product specialists. Comat is therefore able at any time to provide its customers comprehensive, technical advice and can actively provide support for problemsolutions.
In addition, Comat has established itself in the Swiss market as the general agent for well-known international manufacturers. Most of these suppliers are market leaders in their product segments.
With its own calibrating laboratory for pressure and electrical parameters, accredited in accordance with EN ICO/IEC 17025, Comat also provides a calibration service of the utmost accuracy.
Comat AG has devoted itself to unconditional customer satisfaction and subordinates all business activities to this end.
The company’s philosophy proves this clear business policy, both externally as well as internally.
Company
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice. 1 KAT
2008
5
4
3
2
1
Index Page 3
Industrial Relays / Miniature Contactor Page 5
Time Delay Relays / Time Cubes / Time Modules Page 51
Installations Relays / Staircase Lighting Timers Page 103
Monitoring Relays Page 111
SMS Relay / Miniature Controller Comat BoxX Page 133
Comat, since over 35 years a strong name in the field of industrial electronics.
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.2 KAT
2008COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
Notes
Lloyd’s; IEC 61810; EN 60974
Comat products comply with different international standards and are certified accordingly.
A detailed list can be found on our web page:
www.comat.ch
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice. 3 KAT
2008
Typ Page
C2 22C3 23C4 24C5 25C7 16C9 18C10 13C12 14C14 13C21 28C22 28C31 29C32 29C33 30C34 30C35 40C36 40C37 40C38 40C39 30C103.01 37C103.06 37C133.01 37C203.01 37C203.04 37C203.06 37C301.04 37C301.08 45C311.08 45CHA1 12CINT-11 10CINT-12 10CINT-15 10CINT-18 10CINT-21 10CINT-22 10CINT-25 10CINT-28 10CINT-51 11CINT-52 11CINT-53 11CINT-61 11CINT-62 11CINT-63 11CPF11 46CPF22 46CR11C 36CR16AX 36CR16CX 36CR23A 36CR31 17CR33A 36CRS1C 36CT2 32CT3 32CTV11 45KA108 41KA115 41KA208 41KD125 42KD215 42
KD315 42KDM3-24 43KDW3-24 44KR13 19KR23 19KR33 19RC1 33RCL1 33RD1 33RD2 33RD3 33RDL1 33RDL2 33RDL3 33RIC20 50RIC25 50RIC40 50RIC63 50RIC-AUX 50RL1 33SOC-2 49SOC-6 48SS-1BM 48SS-1HM 48SU-404M 48SU-422M 48SU-440M 48
AA2 82AA2M 82AE2 82AE2M 82AM1 84AM2 84AM3 84C52 70C53 70C53.3 71C53.4 71C55 70C55.3 71C55.4 71C56 70C63 68C64 69C65 69C66 69C81 67C82 67C83 67C84 67C85 67CCX-350 95CCX-550 95CEA-126 79CEA-226 77CFG-126 79CIM1 84CM1 85CM1L 85CM2 85CM3 85CN135 90CNR1 86CNS-4 90CPF11 94CPF22 94CPX-129 78CPX-519 77CRA1 82CRE1 82CRT3 83CRV1 83CRV2 83CRV3 83CS1 68CS2 68CS3 68CSV2 83CT1 86CT1L 86CT2 61CT3 61CT30 63CT32 63CT33 63CT36 63CTI-129 78CTI-519 77
CU23 91CWR-102 79CX 38 80CX 39 80CY1 82ECO31 87ECO32 87RS 41-M 76RS 121 74RS 121.P 74RS 121.R 74RS 122-H 75RS 122-M 75RS 122-MH 75RS 321 76RS 521 76SBV11 93SSV11 93SFR1 92SFR2 92
CT512 123CT515 123CT516 123CT524 116CUEBI 124CUEBU 117ECR-3D 121EOCR-AR 120ESU-D2 130EUCR-BR 120MV52 114MV53 115MV62 114SRCT-35 122SSU11 118SSU12 118SSU13 118SSU14 118SSU16 118SSU22 118SSU23 118SSU24 118SSU25 118SSU26 118SSU29 118SSU31 128SSU33 126SSU34 127SSU36 127SSU72 118SSU73 118SSU74 118SSU75 118SSU76 118SSU79 118TSR19 132
A333 107AL1 108AL2 108AL3 108AL4 109AL4C 109AL5 109B103 107CIM1 106CRS1C 106RIC20 110RIC25 110RIC40 110RIC63 110RIC-AUX 110
Industrial Relays Time Delay Relays Monitoring Relays Installation Relays
CMS-10 135
SMS Relay
AF-10 139AF-20 139
Comat BoxX
11PGL 98C11A 98C12B 98C12B0 98C12B1 98CS8 98CS11 98CS18 98EC8 98EC11 98
Socket
Typ Page Typ Page Typ Page Typ Page Type Page
Index
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.4 KAT
2008COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
Notes
Lloyd’s; IEC 61810; EN 60974
Comat products comply with different international standards and are certified accordingly.
A detailed list can be found on our web page:
www.comat.ch
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice. 5 KAT
2008
Indu
stria
l Rel
ays
1Industrial Relays
• Interface Relays• Miniature Relays• Standard Relays• Long Life Relays• Time Cubes and Relay-Modules• DIN Relays• Solid-State Relays• Miniature Contactors
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.6 KAT
2008COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
Serie
s
Sock
et
Conta
ct
Page
Industrial relays
Interface RelaysInterface Module ultra slim CINT11/12 DIN 35 6A 10
Interface Module ultra slim CINT15/18 DIN 35 2A 10
Interface Module 2-pole CINT51 DIN 35 10A 11
Interface Module 2-pole CINT52/53 DIN 35 8A 11
AUTO-ON-OFF-Relays CHA1 DIN 35 10A 12
Interface Relays plug-in C14 /C10 10A 13
Interface Relays plug-in 2-pole C12 5A 14
Miniatur Industrial RelaysMiniature Industrial Relays 2-pole C7 10A 16
Miniature Industrial Relays 3-pole CR31 10A 17
Miniature Industrial Relays 4-pole C9 5A 18
Miniature Signal Relays 2-pole KR13 3A 19
Miniature Signal Relays 2-channel KR23 2x 3A 19
Miniature Signal Relays 3-channel KR33 3x 3A 19
Standard Industrial RelaysStandard Industrial Relays 2-pole C2 10A 22
Standard Industrial Relays 3-pole C3 10A 23
Standard Industrial Relays 4-pole C4 10A 24
High Power Relay 3-pole C5 16A 25
LONG LIFE Industrial RelaysLONG LIFE Industrial Relays 2-pole C21 10A 28
LONG LIFE Industrial Relays 2-pole C22 6A 28
LONG LIFE Industrial Relays 3-pole C31 10A 29
LONG LIFE Industrial Relays 3-pole C32 6A 29
LONG LIFE Power Relays 2-channel C33 2x 10A 30
LONG LIFE Signal Relays 2-channel C34 2x 5A 30
LONG LIFE Signal Relays 3-channel C39 3x 5A 30
Time Cubes and Relays ModulesPlug-in Time Cubes CT2/CT3 32
Plug-in Coil Wirings R-Module 33
Relays Overview
The well proven Industrial Relay according IEC 67.1 as:• Power Relay 10A• Control Relay with twin contacts 6A• Signal relay with gold contacts• Remanence Relay
The well proven Industrial Relay according IEC 67.1for:• ≥ 100 Mio. mechanical switching cycles• ≥ 700000 switching cycles under max. loadas:• Power Relays 10A• Signal Relay with twin contacts 6A
Relays for switching of PLC I /O´S
The space saving alternative makes the best use of the control panel.In various executions:• Power Relay 10A• Control Relay with twin contacts 6A• Signal relay with gold contacts
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice. 7 KAT
2008
Indu
stria
l Rel
ays
1
Serie
s
Sock
et
Conta
ct
Page
Industrial relays
DIN-RelaisPower Relays 1-pole CR16 DIN 35 6A 36
Control Relays 2-channel CR23A DIN 35 2x 3A 36
Control Relays 3-channel CR33A DIN 35 3x 3A 36
Signal Relays 2-pole CR11C DIN 35 1A 36
Step-on Step-off Relays CRS1C DIN 35 6A 36
Power Relays 1-pole C103 DIN 35 6A 37
Power Relays 2-pole C133 DIN 35 6A 37
Control-/Signal Relays 2-channel C203 DIN 35 2x 5A 37
Control Relays 3-channel C301 DIN 35 3x 5A 37
Solide State RelaysUniversal Solide State Relays 1-channel C35 UC 0,8A 40
AC Solide State Relays 2-channel C36 2x 0,8A 40
DC Solide State Relays 1-channel C37 5A 40
DC Solide State Relays 2-channel C38 2x 2A 40
Universal AC Solide State Relays 1-channel KA108 Triac 0,8A 41
Universal AC Solide State Relays 1-channel KA115 Triac 1,5A 41
Universal AC Solide State Relays 2-channel KA208 Triac 2x 0,8A 41
Universal DCSolide State Relays 1-channel KD125 2,5A 42
Universal DC Solide State Relays 2-channel KD215 2x 1,5A 42
Universal DC Solide State Relays 3-channel KD315 3x 1,5A 42
DC Motor Control Relays with brake function KDM3-24 DIN 35 3A 43
UC Solide State Changeover Relays KDW3-24 DIN 35 3A 44
Switching Amplifier 1-channel CTV11 DIN 35 250mA 45
Switching Amplifier 3-channel C301/C311 DIN 35 3x 2A 45
Pulse Shaper CPF11 DIN 35 2A 46
Pulse Shaper CPF22 DIN 35 2x 150mA 46
Miniature ContactorsUniversal Miniature Contactors SOC-6 DIN 35 20A 48
Universal Miniature Contactors SOC-2 DIN 35 20A 49
Installation Contactors RIC20 DIN 35 20A 50
Installation Contactors RIC25 DIN 35 25A 50
Installation Contactors RIC40 DIN 35 40A 50
Installation Contactors RIC63 DIN 35 63A 50
Outline Overview
Direct snap on Industrial Relays:• Power Relay• Contol Relay with twin contacts• Signal Relay with gold contact• Step-on/Step-off Relay
The alternative for highest switching frequency and non-wearing switching.• Triac outputs for AC and DC loads, short circuit resistent.• Transistor outputs for DC loads, short circuit resistent.
With 3 main contacts 20...63A and auxilliary twin signal contacts 10A.Contact openings >3mm, test voltage 4000V.Specially suitable for save breaking in low vol-tage circuits.
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.8 KAT
2008COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
ContactsThere are several different types of contact materials for relays.The main distinction can be made between single contacts and twin contacts. While single contacts are more suitable for higher loads, twin contacts are sig-nificantly more reliable for low switching loads, i.e. < 24V, < 100mA.
Contact materialThere is no all-purpose universal contact.AgNi is used as a standard contact material for a wide range of applications.For applications in aggressive atmospheres, AgNi contacts with hard gold plating (up to 10µm) are recommended. There is however no other purpose then corro-sion protection during storage. Relays with tungsten pre-contacts are available for very high switching currents (up to 500A, 2.5ms.
Minimum loadThe minimum load values are recommended values under normal working conditions i.e. regular switching, no special ambient conditions, etc.Under these conditions reliable switching can be expected.
Contact resistanceIn practice the contact resistance may vary depending on the switching load and other environmental conditions.For higher currents the contact resistance is around 10mΩ.
Contact spacingNormally all open contacts have an air gap between 0,5.. .1.5mm.They are referred to as µ contacts according to the Low-Voltage Directives and associated standards. These contacts are not suitable for safe disconnection.For switching of DC loads, large contact clearances are requested for the quench-ing of the electric arcs. (Pls.refer to special relays: Series connections.)
Switching capacityThe contact switching capacity is the product of switching voltage and switch-ing current.For AC, the permitted switching capacity is generally enough to handle the max. continuous AC1 current over the whole voltage range.It is not allowed to exceed the load limit curve for DC switching because a re-maining switch-off-arc would destroy the relay immediately. The DC switching capacity is 100W (DC 1).
Drive (coil)A distinction is made between standardised voltages according to EN 60947 as guaranteed values, and typical values which can be expected with a high degree of probability.
Pick-up voltage, Release voltageThe pick-up voltage is the voltage at which the relay engages safely. The typi-cal trip voltage for DC is approx. 65% of Unom and approx. 75% of Unom for AC.The release voltage is approx. 25%, resp. 60% of Unom.For DC, these voltages depend strongly on the temperature coefficient for Cu.This is however not the case for AC, where the constant inductive resistance over a wide temperature range is the controlling factor.Under voltages in AC relays results in humming and armature fluttering and should therefore be avoided.
Operating voltage rangeThe upper voltage limit of the coil is determined by the heat and the ambient temperature.The self-heating trough the contacts under high loads should not be under-estimated since it may even be higher than the dissipated energy of the coil. Significantly high but short period overvoltage however provides no problem for intermittent operations.In doubt please consult our specialist or ask for the respective characteristic curve diagram.
Coil connectionsDifferent coil connections can be integrated into the relay as an option. A cost-effective freewheeling diode is available for DC coils. Please note that the stated release times are generally specified without the coil connection.While an additional LED status indicator has practically no effect, a freewheel-ing diode (D) will lead to an increase in release time by a factor 2 to 5, or 0 ms to 30ms.For AC coils, VDRs or RC elements may be used. In this case resonance effects may have to be considered. VDRs and common RC elements may increase release times by < 5ms.
General designComat (Releco) relays are made from carefully selected high-quality materi-als. The components comply with the latest environmental regulations such as RohS.The meticulous design makes the relays particularly suitable for any industrial application and engineering installation.The robust terminals, mechanical position indicator, dynamic and permanent hand activators, all integrated in the standard relay make them particularly service friendly.Colour coded hand test buttons dependent on the type of coil voltage is another useful feature.
Options - Different coil connections- Freewheeling diodes- LED displays- Bridge rectifiers for AC/DC drives, etc.Additionally, because of short-term availability of special versions for practically any drive voltage up to DC 220V/AC 400V the relays are a cost effective solution for many applications For safety reasons, manual operated test buttons may be replaced with a blank button, if required.
Further informationTo select the most suitable relay and to guarantee a reliable operation and a long service life for the application, several factors need to be considered. In particular these are:-Number of cycles-Switching frequency-Ambient conditions-Load type-Switch-on current and load switch-off energy.
ExampleIf the number of cycles are expected to exceed > 100,000 operations per year. (E.g. clock generators, fast running machines), an electronic solution is perhaps more appropriate. Comat is able to offer a suitable relay from our standard product range.In AC applications, crosstalk caused by long control leads is often a problem and can result in constant humming of the relay or even inadvertent triggering due to interference. Here too, we offer solutions.Various, apparently harmless loads may lead to very high switch-on currents or switch-off energy values This may result in an unacceptable reduction of the service life. Inductive DC loads are especially harmful.
Characteristics of various loads:
Heating circuitsNo high switch-on currents, no high switch-off loads.
Incandescent lamps, halogen lampsSwitch-on currents during a few ms in the range 10 x rated IN. Switch-off at rated load.
Low-energy lampsVery high, with very short switch-on currents due to built-in decoupling capaci-tors. Contacts have a tendency to fuse.
Transformers, AC contactorsSwitching on during zero-transition may avoid high inrush currents. If switching before or after the zero crossing, switch-on currents of 8. . .15 x rated IN.may occur. High inductive switch-off energy is possible. The load must be wired, due to EMC problems.
General information
Comat products comply with different international stand-ards and are certified accord-ingly.
A detailed list can be found on our web page:
www.comat.ch
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice. 9 KAT
2008
Indu
stria
l Rel
ays
1
Industrial Relays
Interface Relays
100Apeak
1
2
1+1
100Apeak
C14-A10 CINT11 C10-T13 C10-T12 CINT12 CINT18 CINT15C10-A14 CINT21 CINT22 CINT28 CINT25
CINT51 CINT52 CINT53 C12-A21CINT61 CINT62 CINT63 C12-A22
CHA1
10A8A6A5A2A
300mA50mA10mA5mA1mA
&
Interface Relays Recommended application
twin contacts
Tria
c
Solid
-Sta
te
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.10 KAT
2008COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
CINT1
Interface
DIN
CINT-11, CINT-21
AgSnO2
1500VA...250W300VA/230V100A/2,5ms10x106/105
<100m
0,8...1,2UN
240mW1,1W5ms/10ms
CINT-11/UC.....VCINT-21/UC.....V
24, 230
CINT-15/DC24VCINT-25/DC24V
AgNi + 5µAu1500VA...250W–10A/20ms10x106/105
<100m
0,8...1,2UN
240mW1,1W5ms/10ms
CINT-12/UC.....VCINT-22/UC.....V
24, 230
CINT-12, CINT-22 CINT-15, CINT-25
14
11
12
A1
A2
SOCKET
RELAY
RELAY
(+)
6A 250VA10mA 12V
6A 250VA1mA 1V
2A 24VD1mA 6V
UC50/60Hz /
DC≤10%
CINT-18, CINT-28
2A 250VA10mA 12V
CINT-18/DC24VCINT-28/DC24V
CINT-R1/UC110-240VCINT-R1/UC24V
CINT-R2/UC110-240VCINT-R2/UC24V
CINT-R5/DC24V CINT-R8/DC24V
CIN
T-R2
/UC
24VU
01
COM
AT S
OCK
ET
CIN
T1/U
C6
-24
VUM
ax. 6
A 25
0V
(see
mod
ule)01
MAD
E IN
EC
12
NO
COM
NC
COIL
14
11A2
(–)
A1(+
)
OUT
RELA
Y
(+)
14 11 12
A1 A2
SOCK
ET
RELA
Y
CIN
T12
/UC
24V
6,2
MO
DU
LELA
BEL
A2
A1
12
11
14
6-24
V
LAB
ELM
OD
ULE
12
11
14
A1
A2
6-24
V
A2
A1
12
11
14
6,2 733,4
88,5
41,5
47.0
TS35
TS35
12
11
14
A1
A2
6,2 733,4
93,5
44,3
49,2
CINT2
–...60W–20A/10ms–<100m /200mV
0,7...1,25Un240mW–<1ms
500VA––20A/10ms–<1,5V
0,7...1,25Un240mW–<1ms
MAXMIN
AC230VA
Interface ModuleComplete with integratedLED and switching module.
Test voltage: 3600V
Tamb. operation/storage:-20..+55/-40..+85°C
Interface Modulefor PLC’s and process control.High power contact AgSnO2.With screw terminals (CINT-11)or cage clamp terminals(CINT-21).
Interface Modulefor PLC’s and process control.Signal contact AgNi +5µAu.With screw terminals (CINT-12)or cage clamp terminals(CINT-22).
Interface Modulefor PLC`s and process control.DC solid-state switch NO, pnp.Integrated transient clamp circuit.For fast and high frequencyswitching. With screw terminals(CINT-15) or cage clampterminals (CINT-25).
Contact materialSwitching power AC1Switching power DC1Switching power AC15Peak inrush currentSwitching cycles: mechanical /electricalContact resistance/voltage drop
Operation voltage AC50/60Hz / DCPower consumption Pmax. 24VPower consumption Pmax. AC230VOn delay/ release timeParallel circuit
Data at Tamb. =20°C (standard coil)
Ordering example
Module d’interfaceCINT-21/UC24V
Connector bridgeCINT-BR20(packing unit: 2x 10pin)
Marking labelCINT-BEZ(packing unit: 64 pieces)
Solid-State moduleCINT-R5/CINT-R8
Relay moduleCINT-R1/CINT-R2
Replacement Switching modules
Solid-state
Marking label(supplied withstandard delivery)CINT-BEZ
Connector bridgeCINT-BR20
Solid-state (Triac)
Interface Modulefor PLC`s and process control.AC solid-state switch type NOsynchronous switching triac.For fast and high frequencyswitching. With screw terminals(CINT-18) or cage clampterminals (CINT-28).
With srcew terminals(0,2-2,5mm2)CINT-11, -12, -15, -18
With cage clamp terminals(1x 0,2-2,5mm2)CINT-21, -22, -25, -28
With srcew terminals With cage clampterminals
Interface modules
Accessories/Sparte parts
All modules have an internal parallel diode circuit; green LED status indication.
Interface-Solide-State Modules
and others:www.comat.ch
SPACE SAVING
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice. 11 KAT
2008
Indu
stria
l Rel
ays
1
CINT5
Interface
DIN
CINT6
CINT-51, CINT-61
AgSnO2
2500VA...300W300VA /230V100A/5ms10x106/105
<100m
0,8...1,2UN
480mW1,1W5ms /10ms
CINT-51/ UC.....VCINT-61/ UC.....V
24, 230
AgNi + 5µAu2000VA...250W–15A /20ms10x106/105
<100m
0,8...1,2UN
480mW1,1W5ms/10ms
CINT-52 / UC.....VCINT-62 / UC.....V
24, 230
CINT-52, CINT-62 CINT-53, CINT-63
10A (13A) 250VA50mA 24V
8A 250VA1mA 12V
8A 250VA10mA 24V
UC50/60Hz /
CINT-R21/UC110-240VCINT-R21/UC24V
CINT-R22/UC110-240VCINT-R22/UC24V
CINT-53 / UC.....VCINT-63 / UC.....V
24, 230
CINT-R23/UC110-240VCINT-R23/UC24V
REL
AYS
A1
A2
220-240VU
24 14NO
21 11COM
22 12NC
TS35
14 723,4
93
4845
REL
AYS
22 12NC
21 11COM
24 14NO
A1
A2
220-240VU
14 723,4
TS3591
48,5
42,5
SOCKET
242122141112A1
A2
Ag Ni2000VA...250W–15A/20ms10x106/105
<100m
0,8...1,2UN
480mW1,1W5ms/10ms
CINT-51/61
CINT-52/62CINT-53/63
RELAY
RELAY
MAXMIN
Interface Modules
Interface ModuleComplete with integrated LED andrelay.ul.
Test voltage: 3600V
Isolation / // / :4000Vrms // 2000Vrms
Tamb. operation/storage:-20..+55/-40..+85°C
Interface Modulefor PLC’s and process control.1 x CO high power contactAgSnO2.With screw terminals (CINT-51)or cage clamp terminals(CINT-61).With LED output status display.
Interface Modulefor PLC’s and process control.1x CO signal contactAgNi+5µAu.With screw terminals(CINT-52) or cage clampterminals (CINT-62).With LED output status display.
Interface Modulefor PLC`s and process control.1x CO signal contact AgNi forstandard applications.With screw terminals (CINT-53)or cage clamp terminals(CINT-63).With LED output status display.
Contact materialSwitching power AC1Switching power DC1Switching power AC15Peak inrush currentSwitching cycles: mechanical /electricalContact resistance
Operation voltage AC50/60Hz / DCPower consumption Pmax. 24VPower consumption Pmax. AC230VOn delay/ release timeParallel circuit
Data at Tamb. =20°C (standard coil)
Ordering example
Interface moduleCINT-51/UC24V
Connector bridgeCINT-BR8/5(packing unit: 1x 5pieces)
Marking labelCINT5-BEZ /18(packing unit: 1x 18pieces)
Replacement relay modules
Marking label(supplied withstandard delivery)CINT5-BEZ
Connector bridgeCINT-BR8
With srcew terminals(0,5-2,5mm2)CINT-51, -52, -53
With cage clamp terminals(1x 0,5-2,5mm2)CINT-61, -62, -63
With srcew terminalsWith cage clamp
terminals
All modules have an internal parallel diode circuit; green LED status indication.
Accessories/Spare parts
Relay module
and others:www.comat.ch
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.12 KAT
2008COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
CHA1Interface
AgCdO10A 250V2500VA500VA/230V...250W100A 2,5ms10x106
<100m
0,8..1,2UN
1,1UN (10A)
400mW/24V
Ag300mA /30V10VA-10W0,5A103
<100m
– –– –– –
CHA1
10A 250VA10mA 12V
12 14
11 A3
B1 B2
A1 A2
11,5 58
26,5 17
84 6245
4
TS35
CHA1/UC24VUC50/60Hz /
B1 B2
A1 A2
12 14
11 A3
CHA1/UC24VU
OFF
10A 250VA
ON
ON
AUT
01
10A 250V MADE IN EC-01
24V AC/DC
A1(+) A2(–)
01
24V 300mAB1 B2
S
11 12 14A3
ONOFFAUTO
DIN
10A 250V
24V AC/DC
A1(+) A2(–)
24V 300mA
B1 B2
S
11 12 14A3
ONOFFAUTO
MAXMIN
Interface moduleCHA1/UC24V
Ordering example
Data at Tamb. =20°C (standard coil) Power contact Signal contact
Interface Modulefor control systems with 1x CO high powercontact, 1x NO signal contact 300mA.Installation: 45mm front dimension.Front setting: AUTO-ON-OFF for maintenanceand emergency operation
AUTO-ON-OFF Relay
Contact materialSwitching current /voltageSwitching power AC1Switching power AC15Switching power DC1Peak inrush currentMechanical switching cyclesContact resistance
Operation voltage AC50/60HzOperation voltage DCPower consumption Pmax
Interface ModuleComplet with hand switch and LED forAUTO position indication.
Test voltage: 3000V Tamb. operation/storage:-10..+50/-40..+85°C
and others:www.comat.ch
Marking label(supplied with standard delivery)CHA-BEZ/10
Marking labelCINT5-BEZ /18(packing unit: 1x 18pieces)
FOR YOUR PLC
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice. 13 KAT
2008
Indu
stria
l Rel
ays
1
AgNi+10 Au1500VA/...150W15A(20ms)20x106/≥105
0,8...1,2UN
1,1VA/700mW11/8ms
AgNi+3 Au1500VA/...150W//5A 30VD15A(20ms)20x106/≥105
0,8...1,2UN
1,1VA/700mW11/8ms
AgNi2500VA/...300W//10A 30VD30A(20ms)20x106/≥105
0,8...1,2UN
1,1VA/700mW11/8ms
C10-A10
115, 230
C10 -T13
BX UC50-400Hz /
C10-A10X / AC ..... V
C10-A10X / DC ..... V
C10-A10FX / DC ..... V
C10-A10BX / UC ..... V
C10-T13X / AC ..... V
C10-T13X / DC ..... V
C10-T13FX / DC ..... V
C10-T13BX / UC ..... V
C10 -T12
AC50/60Hz
Standard
StandardDC
≤ 20%
DC≤ 20%
X DC≤ 20%
FX
115, 230
24, 48
12, 24, 48,110
C10-T12X / AC ..... V
C10-T12X / DC ..... V
C10-T12FX / DC ..... V
C10-T12BX / UC ..... V
115, 230
12, 110
24, 48
12, 24, 48,110
24, 48
12, 24, 48,110
RELAY
AC230V
10A 250VA10mA 10V
6A 250VA5mA 5V
6A 250VA1mA 5V
+
45
1
A2 A1
123
14112
z
12, 110 12, 110
+
45
1
z
A2 A1
123
14112
+
45
1
A2 A1
123
14112
z
C14- A10
C14-A10 / AC ..... V
C14-A10 / DC ..... V
24, 115, 230
24, 48,110
10A 250VA10mA 10V
+
45
1
z
A2 A1
123
14112
AgNi2500VA/...300W//10A 30VD30A(20ms)20 x106/≥105
0,8...1,2UN
1,1VA/700mW11/8ms
StandardDC
≤ 20%
AC50/60Hz
Standard
RELAY
AC230V
75
Incl. ClipS10-CG *)
S10-B
S10-B
233 35,5 / 31(C15)
C14: 31C10: 35,5
75
12 11 14
3 2 1
A2 A2 A1
5 6 4CS-116 Incl. Clip
S10-CG
233 35,5 / 31(C14)17
12 11 14
3 2 1
A2 A2 A1
5 6 4CS-116
Incl
. Lab
el: S
10-R
H
C14/C10Interface
RELAY
DC24V
RELAY
UC24V
MAXMIN
1-pole Miniature Industrial Relay• Extremley rigid terminal pins
(Faston 4,8mm)
Test voltage: 5000V Tamb. operation/storage:-20..+60/-20..+100°C
Interface socket CS-106
UniversalPower Relay 10Afor AC- and DC-circuitsranging from 10mA 10V.With lockable manualactivation button andmechanical status display.
Relay like ..A10, butwith twin contacts 6Athe control relay with highestswitching reliability for controlcircuits ranging from 5mA 5V.With lockable manualactivation button andmechanical status display.
Power Relay
Relay C10-A10X/DC24VSocket CS-106 (clip incl.)
Connector S10-B
Ordering example
Data at Tamb. =20°C (standard coil)
Contact materialSwitching load AC1/DC1Peak inrush powerSwitching cycles mech. /electr.(AC1)
Operation voltage AC50Hz/DCPower consumption AC/DCTriggering delay / release time
Connection No. on socket
Designation according to DIN/EN 50011
z = contact opening < 3mm
Connection withinterface socket CS-106
Control Relay
3 Au
Signal Relay
10 Au
WH
:12,
5x
29
Relay like ..T13, but with10 gold plated twinchange over contactsfor highest switching reliability.Suitable for signal circuitsranging from 1mA 5V. Recom-mended for applications up to0,2A 30V. With lockablemanual activation button andmechanical status display.
*) CS-106 standard delivery
BusbarS10-B(Option)
Term. 2 (11)
Term. 5 (A2)
Power Relay
UniversalPower Relay 10Afor AC- and DC-circuitsranging from 10mA 10V.Without manual activationbutton and mechanical statusdisplay.
Interface socket CS-116 Option:Conductor bridge refer (next page)
and otheres:www.comat.ch
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.14 KAT
2008COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
24, 48
AgNi+10 Au1250VA/...150W//5A 30VD15A(20ms)10x106/≥105
0,8...1,2UN
1,1VA/700mW10/8ms
AgNi + 0,3µ Au1250VA/...150W//5A 30VD15A(20ms)10x106/≥105
0,8...1,2UN
1,1VA/700mW10/8ms
C12-A21
115, 230
C12-A22
BX UC50-400Hz /
C12-A21X / AC ..... V
C12-A21X / DC ..... V
C12-A21FX / DC ..... V
C12-A21BX / UC ..... V
C12-A22X / AC ..... V
C12-A22X / DC ..... V
C12-A22FX / DC ..... V
C12-A22BX / UC ..... V
AC50/60Hz
Standard
StandardDC
≤ 20%
DC≤ 20%
X DC≤ 20%
FX
115, 230
24, 48
12, 110
RELAY
AC230V
5A 250VA10mA 10V
5A 250VA5mA 5V
12, 110
+
45
7
A2 A1
22
9
24
8
21
112
314
211
z
A26
+
45
7
A2 A1
22
9
24
8
21
112
314
211
z
A26
C10: 35,5
B20-G
B20-R
B20-B
V40-G
V40-R
V40-B
V10-G
V10-R
V10-B
A2-A2
RELAY
DC24V
75
17
12 11 14
3 2 1
A2 A2 A1
5 6 4CS-112
22 21 24
9 8 7
Incl. ClipS10-CG
233 35,5
12 11 14
3 2 1
A2 A2 A1
5 6 4CS-112
22 21 24
9 8 7
Incl
. Lab
el: S
10-R
H
C12Interface
MAXMIN
12, 24, 48, 110 12, 24, 48, 110
2-pole Miniature Industrial Relay• Rigid terminal pins
Test voltage: 5000V 3000V Tamb. operation/storage:-20..+60/-20..+100°C
Interface socket CS-112
Universal-Control Relay 5AWith two change over contactsfor AC- and DC- circuitsranging from 10mA 10V.With lockable manualactivation button andmechanical status display.
Signal Relay 5AWith gold plated twin changeover contacts for increasedswitching reliability.Suitable for AC- and DC-circuits ranging from 5mA 5V.With lockable manualactivation button andmechanical status display.
Data at Tamb. =20°C (standard coil)
Contact materialSwitching load AC1/DC1Peak inrush powerSwitching cycles mech. /electr.(AC1)
Operation voltage AC50Hz/DCPower consumption AC/DCTriggering delay / release time
Connection No. on socket
Designation according to DIN/EN 50011
z = contact opening < 3mm
Connection withinterface socket CS-112
Signal Relay
10 Au
WH
:12,
5x
29
Control Relay
Option: Conductor bridge
Relay C12-A21X/DC24VSocket CS-112 (clip incl.)
Conductor bridge V40-B
Ordering example
Type:
Conductor bridge for interface socket CS-112 and CS-116
and otheres:www.comat.ch
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice. 15 KAT
2008
Indu
stria
l Rel
ays
1
Industrial Relays
Miniature Relays
2
3
4
1 + 1
2x 1
3x 1
C7-A20 C7-W10 C7-T21 C7-T22 KR13
CR31
C9-A41 C9-R21 C9-A42
C7-H23
KR23
KR33
500Apeak
10A6A5A3A
10mA5mA1mA100µA
&
Miniature Relays Recommended application
twin contacts
Rem
anen
ce
Comat products comply with different international stand-ards and are certified ac-cordingly.
A detailed list can be found on our web page:
www.comat.ch
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.16 KAT
2008COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
+78
4
z
A2 A15
C7-A20 C7-T21 C7-T22 C7-W10
C7-A20 X / AC ..... V
C7-A20 / DC ..... V
C7-A20D X / DC ..... V
24, 48, 115, 230
12, 24, 48, 110, 125
12, 24, 48, 110, 125
C7-T21 X / AC ..... V
C7-T21 / DC ..... V
C7-T21D X / DC ..... V
24, 48, 115, 230
12, 24, 48, 110, 125
12, 24, 48, 110, 125
24, 48, 115, 230
12, 24, 48, 110, 125
12, 24, 48, 110, 125
C7-W10 X / AC ..... V
C7-W10 / DC ..... V
C7-W10D X / DC ..... V
24, 48, 115, 230
12, 24, 48, 110, 125
12, 24, 48, 110, 125
W/Ag2500VA...250W500A(2,5ms)20x106/≥ 3x105
0,8...1,2UN
1,8VA/1,5W20/10ms
AgNi2500VA...250W30A(20ms)20x106/≥ 3x105
0,8...1,2UN
1,5VA/1W16/8ms
AgNi+0,2zAu1200VA...150W15A(20ms)20x106/≥ 2x105
0,8...1,2UN
1,5VA/1W16/8ms
AgNi+10zAu1200VA...150W15A(20ms)20x106/≥ 2x105
0,8...1,2UN
1,5VA/1W16/8ms
DC≤10%
D, DX
DC≤10%
Standard
AC50/60Hz
Standard
AC230VA
ClipS9-CG
233 37,5
2
14 122224
A2 A1
56
1121
CS-109
3 124
8 9 7
22,5
75
14 122224
A2 A1
56
1121
CS-109
3 124
8 9 7
S7-B
(A2)
10A 250VA10mA 10V
6A 250VA5mA 5V
6A 250VA1mA 5V
10A 250VA10mA 10V
+
78
4
z
A2 A1
5
C7-H23
10/6A 250VA10mA 10V // 1mA 5V
+
78
2
A2 A1
244
226
21
114
312
5
11
z
+
78
2
A2 A1
244
226
21
114
312
5
11
z
+
78
2
A2 A1
244
226
21
114
312
5
11
z
+
5 78 6
3 14 2
z
A2 21 11 A1
24 22 14 12
230
24
C7-H23X / AC ..... V
C7-H23DX / DC ..... V
+
5 78 6
3 14 2
z
A2 21 11 A1
24 22 14 12
+
5 78 6
3 14 2
z
A2 21 11 A1
24 22 14 12
+
5 78 6
3 14 2
z
A2 21 11 A1
24 22 14 12
+
78
2
A2 A1
244
226
21
114
312
5
11
z
21
1324
11
8 756B1A2 A1
24 1222 14
2
4
6
8
1
3
5
7CS-18
22,5
75
223 37,5
Clip RC-G
AgNi // AgNi+3zAu2500VA // 1500VA...250W // ...180W30A // 15A(20ms)20x106/≥ 2x105
0,8...1,2UN
1,4VA/1,1W15/8ms (30ms “DX”)
X
C7
DC24VD AC230VA DC24VD AC230VA
MAXMIN
C7-T22 X / AC ..... V
C7-T22 / DC ..... V
C7-T22D X / DC ..... V
37,5
Relay C7-A20X/AC230VSocket ...
Socket CS-18Retaining clip RC-G (option)
Socket CS-109 (clip incl.)A2-connector S7-B (option)
Socket S7-P (page 5*)Retaining clip RC-G (option)
Interface socket CS-109 (all connections on top)
Connection with socketCS-18
High PowerRelay
Power Relay Control Relay
Relay like ..A20, butwith twin contacts 6Athe control relay withhighest switching reliabil-ity for control and signalcircuits ranging from5mA 5V.
UniversalPower Relay 10Awith 2 power changeover-contacts this is a robustrelay for AC andDC circuits ranging from10mA10V.
Heavy duty Relay for500A inrush currentwith tungsten specialearly make contact.Specially suitable forfilament and halogenlamps, transformers, etc.No mecanical flag indi-cator.
Relay like ..T21,but 10 gold platedcontactsthe twin contact relaywith highest switchingreliability for signal circuitsranging from 1mA 5V.Recommended upto0,2A 30V.
Ordering example
Connection with socketCS-109
Data at Tamb. =20°C (standard coil)
Contact materialSwitching power AC1Switching power DC1Peak inrush powerSwitch. cycles mech./electr.(AC1)
Operation voltage AC50Hz/DCPower consumption AC/DCTriggering delay / release time
Connection No. on socket
Designation according to DIN/EN 50011
= contact opening < 3mm
System socket CS-18 (connections 5 and 6 on bottom)
Option X = with
2-pole Miniature IndustrialRelay• lockable manual operation• mechanical flag indicator
Test voltage: 2500V 2500V
Tamb. operation/storage:-20..+60/-40..+85°C
Signal Relay
WH
: 21
x28
A2-con-nectorS7-B
= Type (option)
Plug-in R/C-unitRC0047-100/AC250V
Power RelaySignal Relay
Power Relay 10Awith supplementary twincontact 6A (3zAu) fora secondary circuit switch,i.e. to ensure reliablesignal of relay switchposition to the centralcontrol, SPC, distributionsystem.
Miniature 0,2 Au 10 Au
and others:www.comat.ch
Entire series of C7. Comply to IEE 323 and IEE 344 (seismic qualified)
SEISMIC APPROVED
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice. 17 KAT
2008
Indu
stria
l Rel
ays
1CR31
10A 250VA10mA 12V
AgNi 90/102500VA/...250W20A(20ms)20x106/≥105
0,75-1,7UN/0,8-1,65UN
1,0VA /0.75WAC:<25/10ms; DC:15/10ms15/25ms
StandardDC
≤10%
AC50/60Hz
Standard
CR31
+1314
5
A2 A1
222
24821
z
A214
632
334
931
412
114
711
C31 / AC ..... V
C31 / DC ..... V
C31D / DC ..... V
24, 115, 230
24
24DC≤ 20%
X DC≤10%
FX
2 8 5 3 9 6 1 7 4AgNi10A 250Va
CR31
/AC
230
VA
A2 A1
01
22 2124 323134121114
MADEIN EU
2 8 5 3 9 6 1 7 4AgNi10A 250Va
CR31
D/DC
24VD
A2 A1
01
22 2124 323134121114
+
MADEIN EU
COM
NO
NC
470E/0,22µF
4k7/0,01µF
CMX1/UC110-240VCMX1/UC24-60V
R/C-Unit
27
75
98 7
5 6 4
2 3 1
3424 14
3222 12
21 31 11
A214
A113
+
12A 300V
CS-
30
NO
NC
COM
MAD
E IN
01
COIL
EU
26 332
Relay
LED orR/C-Module
Clip/Marking tag CC-30
CMR1/UC24-60V
CMR1/UC110-240V
R/C-Unit
MAXMIN
Ind.Relay CR31/DC24VSocket CS-30 (clip incl.)
LED-Mod. CMX1/UC24-60V
Retaining clip CC-30
Ordering example
3-poleMiniature Industrial Relay• lockable manual operation• mechanical flag indicator
Test voltage: 2500V 2500V Tamb. operation/storage:-40..+60/-40..+80°C
System socket CS-30 (connections above)
= Contact opening >0,5mm
Power Relay
Universal Power Relay 10AThe CR31 is a 3-pole miniature industrial relay which accomplishesthe highest performance with low consumption and a switchingcapacity of 10A at AC1.The manual test tab, optionally lockable makes the CR31 the idealrelay for all control and automation uses.R/C-units and LED indication are available optionally in form ofplug-in modules for the socket CS-30.
Connection No. on socket
Designation according to DIN/EN 50011
Contact materialSwitching power AC1/DC1Peak inrush powerSwitch.cycl. mech. /electr.(AC1)
Operation voltage DC/AC50HzPower consumption AC/DCTrigg.delay/release timeTrigg.delay/release time DC
Data at Tamb. =20°C (standard coil)
Plug-in Socket Module
Miniature
Connection with socketCS-30
and others:www.comat.ch
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.18 KAT
2008COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
C9-A41 C9-R21C9-A42
C9-R21 / AC ..... V
C9-R21 / DC ..... V
24, 48, 115, 230
12, 24, 48
C9-A41 X / AC ..... V
C9-A41 / DC ..... V
C9-A41D X / DC ..... V
24, 48, 115, 230
12, 24, 48, 110, 125
12, 24, 48, 110, 125
C9-A42 X / AC ..... V
C9-A42 / DC ..... V
C9-A42D X / DC ..... V
24, 48, 115, 230
12, 24, 48, 110, 125
12, 24, 48, 110, 125
AgNi+0,2zAu700VA/...75W15A(10ms)20x106/≥105
0,8...1,2UN
1,5VA/1W10/6ms
AgNi+10z Au700VA/...75W15A(10ms)20x106/≥105
0,8...1,2UN
1,5VA/1W10/6ms
AgNi+0,2zAu700VA/...75W15A(10ms)20x106/≥105
0,8...1,2UN
ON:1,2VA/W; OFF: 0,3VA/W10/8ms ( >50ms)
AC50/60Hz
Standard
DC≤10%
Standard
DC≤10%
D, DX
22,5
75
CS-114
41 31 21 11
A1A2
44 34 24 14
42 32 22 12
12 11 10 9
4 3 2 1
14 13
8 7 6 5
ClipS9-CG
223 37,5
S9-P
2
6
10
1
5
9
13
34
78
1112
14
22,5
30
1 2 3 4
5 6 7 8
9 10 11 12
13 14
3 x 4,4
0,6
6,35
4,05
13,2
ø1,4
6,35
PR INT
12,64
0,5
x1,2
RC-G
AC230VA
5A 250VA10mA 10V
5A 250VA5mA 5V
5A 250VA10mA 10V
+z
42
44
32
34
22
24
12
14
41
A2
21
A1
31 1114 1310 91112
2 134 6 578
+z
42
44
32
34
22
24
12
14
41
A2
21
A1
31 1114 1310 91112
2 134 6 578
14 13
14
+z
58
22
24
12
14
91221
A2 A1
1110
A3
OFF+
ON
X
10 AuC9
DC24VD AC230VA
MAXMIN
4-pole Miniature Industrial Relay• lockable manual operation• mechanical indication
Test voltage: 2500V 1000V Tamb. operation/storage:-20..+60/-40..+85°C
Control Relay Remanence Relay
Universal Control Relaywith 4 changeover contactsfor AC and DC circuits rangingfrom 10mA10V.
Remanence Relaywith AC or DC coilA1(13) = ON; A3(10) = OFF.Minim. triggering time 50ms,permanent triggering admis-sible.Test voltage 2500V .
Without option X.
Relay like ..A41, but with10z gold plated contactsfor control and signal circuitsranging from 5mA 5V.Recommend. upto 0,2A 30V.
System socket CS-114
Relay C9-A41X/AC230VSocket CS-114 (clip incl.)
Socket S9-PRetaining clip RC-G (option)
Ordering example
Option X = with
Connection with socketCS-114
Data at Tamb. =20°C (standard coil)
Contact materialSwitching power AC1/DC1Peak inrush powerSwitching cycles mech. /electr.(AC1)
Operation voltage AC50Hz/DCPower consumption AC/DCTriggering delay / release time
Connection No. on socket
Designation according to DIN/EN 50011
= contact opening < 3mm
Signal Relay
Socket for print mounting S9-P
View onsolder side
37,5
WH
: 21
x28
= Type (Option)
Miniature
and otheres:www.comat.ch
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice. 19 KAT
2008
Indu
stria
l Rel
ays
1
KR13 KR23 KR33
22,5
30
S7-P
2
4
6
8
1
3
5
7
2
4
6
8
1
3
5
7
10
0,6
7,25
5,9
4,7
ø 2,2
14,513,15,2
RC-G
0,5
x2
Ag-alloy+3..5 Au750VA/...90W//3A 30VD6A(20ms)20x106/≥105
0,8...1,2UN
350mW6/4ms (X: 6ms)
Ag-alloy+3..5 Au750VA/...90W//3A 30VD6A(20ms)20x106/≥105
0,8...1,2UN
250mW6/4ms (X: 6ms)
Ag-alloy+3..5 Au750VA/...90W//3A 30VD6A(20ms)20x106/≥105
0,8...1,2UN
250mW6/4ms (X: 6ms)
0101
100z
A100
mV.
..3
A30
VD/2
50VA
+
z
5 78 6
3 14 2KR
13X/
DC
24VD
0101
100z
A100
mV.
..3
A30
VD/2
50VA
KR23
X/D
C24
VD
++
2 1
8
6 7
3 14 2z z
KR13A / DC ..... V
KR13X / DC ..... V
12, 24, 48
12, 24, 48
KR23A / DC ..... V
KR23X / DC ..... V
12, 24
12, 24
KR33A / DC ..... V
KR33X / DC ..... V
12, 24
12, 24DC≤ 20%
X
DC≤ 20%
A
R R B
22,5
75
21
1324
11
8 756B1A2 A1
24 1222 14
2
4
6
8
1
3
5
7CS-18
BClip GC-T *)
Clip RC-G
Clip GC-W *)
35,5223
R
22 x 65
22 x 28
3A 250VA //110VD100 A 100mV
3A 250VA //110VD100 A 100mV
3A 250VA //110VD100 A 100mV
+
5 78 6
3 14 2
z
24 23 14 13
A2 23 13 A1
2 14 1 14
++
2 1
6 7
3 14 2
8
z
2 13 1 13
A2 2 A1 1 A1
1324
5 78 6
2 13z
13 2 14 1 143 14
A2 1 A12 A1 3 A1++ +
35,5 KR33X/DC24VD
100zA100mV...3A30VD/250VA
relay
1324
5 78 6
2 13
++ +
z z z
01
KR 2x3,5 Au
3x3,5 Au
MAXMIN
3,5 Au
Miniature Industrial Relay• 1- to 3-channel• for control and signal circuits• Power consumption only 250mW perchannel
Test voltage: 2000V 1000V Tamb. operation/storage:-20..+60/-40..+85°C
*) Standard delivery with relay (Case B)
System socket CS-18 Socket for print mounting S7-P
Universal gold platedtwin contact relay1-channel, totaly incapsula-ted.For highest switching reliabili-ty in control and signal circuitsranging from 100 A 100mV.
Relay like KR13, but2-channelwith a width of 11mm perchannel this relay is especiallyspace-saving and cost-effec-tive.
Relay like KR13, but3-channelwith a width of 7,3mm perchannel this relay is especiallyspace-saving and cost-effec-tive.
Miniature
Relay KR23X/DC24VSocket CS-18 or S7-P
Retaining clip RC-G (option)
Ordering example
Data at Tamb. =20°C (standard coil )
Contact materialSwitching load AC1/DC1Peak inrush powerSwitching cycles mech. /electr. (AC1)
Operation voltagePower consumption per channelTriggering delay / release time
Connection No. on socket
Designation according to DIN/EN 50011
= contact opening < 3mm
Connectio with socketCS-18
View onsolder side
Case Case Case
Case
Case
WH
:G
eh.R
: 22
x28
Geh
.B: 2
2x
65
Signal Relay Signal Relay Signal Relay
and others:www.comat.ch
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.20 KAT
2008COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
Notes
Lloyd’s; IEC 61810; EN 60974
Comat products comply with different international standards and are certified accordingly.
A detailed list can be found on our web page:
www.comat.ch
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice. 21 KAT
2008
Indu
stria
l Rel
ays
1
Industrial Relays
Standard Relays
2
3
4
C2-A20 C2-T21 C5-M10C3-R20
C3-A30 C3-T31 C3-T32 C5-A30
C4-A40
16A10A6A1A
10mA5mA1mA
Standard Relays Recommended application
twin contacts
Series
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.22 KAT
2008COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
10A 250VA10mA 10V
C2-A20 C2-T21
224
Clip S3-C
AC230VA
6 5 4 3
24 22 12 14
7 8 1 2
A2 21 11 A1
EC-8 10A400V
10A300VListed10A
400V
02
62
38
AgNi2500VA/...250W30A(20ms)20x106/ ≥ 5x105
0,8...1,2UN
2,2VA/1,3W16/8ms
AgNi+0,2zAu1200VA/...150W15A(20ms)20x106/ ≥ 2x105
0,8...1,2UN
2,2VA/1,3W16/8ms
C2-A20 X / AC ..... V
C2-A20 / DC ..... V
C2-A20D X / DC ..... V
24, 48, 115, 230
12, 24, 48, 110, 125, 220
12, 24, 48, 110, 125, 220
C2-T21 X / AC ..... V
C2-T21 / DC ..... V
C2-T21D X / DC ..... V
24, 48, 115, 230
12, 24, 48, 110, 125, 220
12, 24, 48, 110, 125, 220
AC50/60Hz
Standard
DC≤10%
Standard
DC≤10%
D, DX
8
6A 250VA5mA 5V
27 8 1
4 36 5
z
A2 21 11 A1
24 22 1412
+
27 8 1
4 36 5
z
A2 21 11 A1
24 22 1412
+
C2
DC24VD
MAXMIN
Standard
Relay like ..A20, butwith doubel contacts 6AThe control relay with highestswitching reliablility for controland signal circuits rangingfrom 5mA 5V.
UniversalPower Relay 10AWith 2 power changeover-contacts this is the robustrelay for AC and DC circuitsranging from 10mA10V.
Data at Tamb. =20°C (standard coil )
Power Relay Control Relay
Economy socket EC-8
Contact materialSwitching load AC1/DC1Peak inrush powerSwitching cycles mech. /electr.(AC1)
Operation voltage AC50Hz/DCPower consumption AC/DCTriggering delay / release time
Ordering example
Relay C2-A20X/AC230VSocket EC-8
Retaining clip S3-C (option)
Connection No. on socket
designation according to DIN/EN 50011
= contact opening < 3mm
Connection with socketEC-8
Option X = with
58
WH
: 35
x35
2-pole Miniature Industrial Relayaccording to IEC 67-1• lockable manual operation• mechanical flag indicator
Test voltage: 2500V 2500VTamb. operation/storage:-20..+60/-40..+85°C
= Type “X” (option)
and others:www.comat.ch
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice. 23 KAT
2008
Indu
stria
l Rel
ays
1
10A 250VA10mA 10V
AC230VA
C3-A30 C3-T31 C3-R20C3-T32
AgNi2500VA/...250W30A(20ms)20x106/ ≥ 3x105
0,8...1,2UN
ON/OFF 1,5/0,5 VA//W16/10ms ( >50ms)
AgNi2500VA/...250W30A(20ms)20x106/ ≥ 5x105
0,8...1,2UN
2,2VA/1,3W16/8ms
AgNi+0,2 z Au1200VA/...150W15A(20ms)20x106/ ≥ 2x105
0,8...1,2UN
2,2VA/1,3W16/8ms
AgNi+10z Au1200VA/...150W15A(20ms)20x106/ ≥ 2x105
0,8...1,2UN
2,2VA/1,3W16/8ms
C3-R20 / AC ..... V
C3-R20 / DC ..... V
24, 48, 115, 230
12, 24, 48, 110, 125
C3-T31 X / AC ..... V
C3-T31 / DC ..... V
C3-T31D X / DC ..... V
24, 48, 115, 230
12, 24, 48, 110, 125, 220
12, 24, 48, 110, 125, 220
C3-T32 X / AC ..... V
C3-T32 / DC ..... V
C3-T32D X / DC ..... V
24, 48, 115, 230
12, 24, 48, 110, 125, 220
12, 24, 48, 110, 125, 220
C3-A30 X / AC ..... V
C3-A30 / DC ..... V
C3-A30D X / DC ..... V
24, 48, 115, 230
12, 24, 48, 110, 125, 220
12, 24, 48, 110, 125, 220
EC-11 10A400V
10A300VListed10A
400V
029 8 7 5 3 4
34 32 24 22 14 12
10
A2
11 6 1 2
31 21 11 A1SD-1W
5789
11 1610 2
3 4
A2 31 21 11 A1
121422243234
04
210
6 54
3
78
9
11 1
SW
ISS
C11A
10A
250
VA
10A400VA
CONNECTOR C-A2
38
75
38
3230
C-A2
204
Clip S3-C
224
Clip S3-C
DC≤10%
D, DX
DC≤10%
Standard
AC50/60Hz
Standard
11
6A 250VA5mA 5V
6A 250VA1mA 5V
10A 250VA10mA 10V
14458
+
3793234 2224
10 11
12
A2 21 A131 116 1 2
z
14458
+
3793234 2224
10 11
12
A2 21 A131 116 1 2
z
14458
+
3793234 2224
10 11
12
A2 21 A131 116 1 2
z
10 11 6 1 2
1448
+
392224 12
A2 A3 A121 11
z
+OFF ON
C3
DC24VD AC230VA DC24VD
10 Au
MAXMIN
Standard
3-pole Miniature Industrial Relayaccording to IEC 67-1• lockable manual operation• mechanical flag indicator
Test voltage: 2500V 2500VTamb. operation/storage:-40..+60/-40..+85°C
Data at Tamb. =20°C (standard coil )
Remanence RelayPower Relay Control Relay
Relay like ..A30, butwith twin contacts 6AThe control relay with highestswitching reliablility for controland signal circuits rangingfrom 5mA 5V.
UniversalPower Relay 10AWith 3 power changeover-contacts this is the robustrelay for AC and DC circuitsranging from 10mA10V.
Remanence Relay 10Awith AC or DC coilA1(2)=ON; A3(6)=OFF.Minim. triggering time 50ms,permanent triggering admis-sible.
Without option X.
Relay like ..T31, but with10 gold plated contactsThe twin contact relay withhighest switching reliability forsignal circuits ranging from1mA 5V.Recommend. upto 0,2A 30V.
Contact materialSwitching load AC1/DC1Peak inrush powerSwitching cycles mech. /electr.(AC1)
Operation voltage AC50Hz/DCPower consumption AC/DCTriggering delay / release time
Ordering example
Relay C3-A30X/AC230VSocket EC-11 or C11A
Retaining clip S3-C (option)
Connection No. on socket
Designation according to DIN/EN 50011
= contact opening < 3mm
Connection with socketsEC-11, C11A, C12B
Signal Relay
*) with plugged-inneutral conductorconnector C-A2(standard delivery).
For suitable coil wiringssee “R-modules” page 31
58
WH
: 35
x35
Option X = with
Economy socket EC-11
System socket C11A *)
= Type “X” (option)
and others:www.comat.ch
SEISMIC APPROVED
Types C3-A30 comply toIEE 323 and IEE 344.(seismic qualified)
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.24 KAT
2008COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
10A 250VA10mA 10V
AC230VA
C4-A40
AgNi2000VA/...250W30A(20ms)20x106/ ≥ 6x105
0,8...1,2UN
2,4VA/1,4W20/8ms
DC≤10%
Standard
AC50/60Hz
StandardC4-A40 X / AC ..... V
C4-A40 / DC ..... V
C4-A40D X / DC ..... V
24, 48, 115, 230
12, 24, 48, 110, 125, 220
12, 24, 48, 110, 125, 220DC≤10%
D, DX
Clip S3-CMG
284 5038
92
3194112
A214
216 113
348
327
4411
4210
245
224
142
1 12
CS-14
10
11
9
1214
7
8
4
5
1
2
6
313
A113
14 13
4 1710
+z
5 2811
42
44
32
34
22
24
12
14
6 391241
A2
21
A1
31 11
C4
MAXMIN
Standard
Ordering example
Relay C4-A40X/AC230VSocket CS-14
Socket CS-14
Power Relay
UniversalPower Relay 10AWith 4 power changeover-contacts this is the robustrelay for AC and DC circuitsranging from 10mA10V.
4-pole Industrial Relay withfaston pins• lockable manual operation• mechanical flag indicator
Test voltage: 2500V 2500V Tamb. operation/storage:-40..+60/-40..+85°C
Contact materialSwitching load AC1/DC1Peak inrush powerSwitching cycles mech. /electr.(AC1)
Operation voltage AC50Hz/DCPower consumption AC/DCTriggering delay / Release time
Data at Tamb. =20°C (standard coil )
Connection No. on socket
Designation according to DIN/EN 50011
= contact opening < 3mm
Connection with socketCS-14
Option X = with
50
WH
: 35
x35
= Type “X” (option)
and others:www.comat.ch
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice. 25 KAT
2008
Indu
stria
l Rel
ays
1C5-A30 C5-M10
AgNi4000VA/...400W40A(20ms)20x106/ ≥ 3x105
0,8...1,2UN
2,4VA/1,4W20/10ms
AgNi4000VA/...880W40A(20ms)20x106/ ≥ 3x105
0,8...1,2UN
2,4VA/1,3W20/10ms
DC≤10%
Standard
AC50/60Hz
Standard
AC230VA
C5-A30 X / AC ..... V
C5-A30 / DC ..... V
C5-A30D X / DC ..... V
12, 24, 48, 110, 125, 220
12, 24, 48, 110, 125, 220
C5-M10 X / AC ..... V
C5-M10 / DC ..... V
C5-M10D X / DC ..... V
12, 24, 48, 110, 125, 220
12, 24, 48, 110, 125, 220DC≤10%
D, DX
26,53,5 50
Clip S3-CMG
38
80
6 5 434 24 14
BA2
9 8 731 21 11
AA1
3 2 132 22 12
CS-15
16A 400VA 10A @220VD
16A 500VA /6A AC1510mA 10V
16A 500VA /6A AC1510mA 10V
B A
2 13
+z
5 46
32
34
22
24
12
14
8 79
A2
21
A1
31 11B A
+
6 414
A2 A1
13 S N
24, 48, 115, 230, 400*) 24, 48, 115, 230, 400*)
C5
DC24VD
MAXMIN
Standard
*) 400V available only without LED (X) !
Ordering example
Relay C5-A30X/AC230VSocket CS-15
Socket CS-15
3-pole Industrial Relay withfaston pins• lockable manual operation• mechanical flag indicator
Test voltage: 4000V 4000V Tamb. operation/storage:-40..+60/-40..+85°C
Contact materialSwitching load AC1/DC1Peak inrush powerSwitching cycles mech. /electr.(AC1)
Operation voltage AC50Hz/DCPower consumption AC/DCTriggering delay / Release time
Data at Tamb. =20°C (standard coil )
Connection No. on socket
Designation according to DIN/EN 50011
= contact opening < 3mm (1,7+1,7)
High Power Relay for AC and DC
Highpower Relay,in particular for DC loadsupto 10A 220VD (DC1)With 2 contacts in seires anda blow magnet for safe arcextinguishing.
UniversalPower Relay 16AWith 3 power changeover-contacts this is the robustrelay for AC and DC circuitsranging from 10mA10V.
Connection with socketCS-15
Option X = with= Type “X” (option)
50
WH
: 35
x35
and others:www.comat.ch
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.26 KAT
2008COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
Notes
Lloyd’s; IEC 61810; EN 60974
Comat products comply with different international standards and are certified accordingly.
A detailed list can be found on our web page:
www.comat.ch
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice. 27 KAT
2008
Indu
stria
l Rel
ays
1
Industrial Relays
Long Life Relays
2
3
2x 1
3x 1
C21 C22
C31 C32
C33 C34
C39
10A6A5A1A
10mA5mA1mA
Longe Life Relays Recommended application
twin contacts
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.28 KAT
2008COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
10A 250V/4A 440VA10mA 10V
224
Clip HF-32
6 5 4 3
24 22 12 14
7 8 1 2
A2 21 11 A1
EC-8 10A400V
10A300VListed10A
400V
02
62
38
Ag (AgCuNi)2500VA/...300W40A(20ms)100x106/ ≥ 7x105
0,8...1,2/0,8...1,25UN
2,5VA/1,2W15/d8, a15ms
Ag (AgCuNi)1500VA/...200W15A(20ms)100x106/ ≥1,5x105
0,8...1,2/0,8...1,25UN
2,5VA/1,2W15/d8, a15ms
C21 C22
C21 L / AC ..... V
C21 / DC ..... V
C21D L / DC ..... V
24, 48, 115, 230
12, 24, 48, 110, 220
12, 24, 48, 110, 220
C22 L / AC ..... V
C22 / DC ..... V
C22D L / DC ..... V
24, 48, 115, 230
12, 24, 48, 110, 220
12, 24, 48, 110, 220DC≤10%
D, DL
AC50/60Hz
Standard
DC≤10%
Standard
6A 250VA1mA 5V
27 8 1
4 36 5
z
A2 21 11 A1
24 22 1412
+
27 8 1
4 36 5
z
A2 21 11 A1
24 22 1412
+
C20Long Life
8
312220 - 240 V 50 / 60 Hz
LOCK
C21L / AC 230 VA
1 32 45
A12
A2
RELAY
N
10A 400V AC1 AgNi
7...L
C21A
5
6 524 22
218
3 41214
111
723480
LOCK
C22DL / DC 24VD
1 32 45
A12
A2
RELAY
..D
+
..L
6A 250V AC1 AgNi
7
C22D
5
6 524 22
218
3 41214
111
MAXMIN
51
= Type “L” (option)
Power Relay
Economy socket EC-8
Ordering example
Relay C21/AC230VSocket EC-8
Retaining clip HF-32 (option)
UniversalPower Relay 10Awith 2 power changeover-contacts this is the robust relayfor AC and DC circuits rangingfrom 10mA10V.
Relay like ..C21, butwith twin contacts 6AThe control relay with highestswitching reliablility for controland signal circuits rangingfrom 1mA 5V.
Control Relay
2-pole Industrial Relay accordingto IEC 67-1• lockable manual operation• mechanical flag indicator
Test voltage: 2500V 1500V Tamb. operation/storage:-40..+70/-40..+85°C
Connection No. on socket
Designation according to DIN/EN 50011
Connection on socketsEC-8
= contact opening < 3mm
Data at Tamb. =20°C (standard coil )
Contact materialSwitching power AC1/DC1Peak inrush powerSwitching cycles mech. /electr.(AC1)
Operation voltage AC50Hz/DCPower consumptionTriggering delay / release time
WH
: 35
x35
Option L = with
and others:www.comat.ch
THE UNINDESTRUCTIBLE ONES
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice. 29 KAT
2008
Indu
stria
l Rel
ays
1
DC≤10%
D, DL
AC50/60Hz
Standard
DC≤10%
Standard
Ag (AgCuNi)1500VA/...200W15A(20ms)100x106/ ≥1,5x105
0,8...1,2/0,8...1,25UN
2,5VA/1,2W15/d8, a15ms
Ag (AgCuNi)2500VA/...300W40A(20ms)100x106/ ≥ 7x105
0,8...1,2/0,8...1,25UN
2,5VA/1,2W15/d8, a15ms
C31 C32
C31 L / AC ..... V
C31 L / DC ..... V
C31D L / DC ..... V
24, 48, 115, 230
12, 24, 48, 110, 220
12, 24, 48, 110, 220
C32 L / AC ..... V
C32 / DC ..... V
C32D L / DC ..... V
24, 48, 115, 230
12, 24, 48, 110, 220
12, 24, 36, 48, 110, 220
10A 250V/4A 440VA10mA 10V
6A 250VA1mA 5V
14458
+
3793234 2224
10 11
12
A2 21 A131 116 1 2
z
14458
+
3793234 2224
10 11
12
A2 21 A131 116 1 2
z
C30Long Life
11
312220 - 240 V 50 / 60 Hz
LOCK
C31L / AC 230 VA
1 32 4510A 400V AC1 AgNi
C31A
5
8934 32
3111
24 2257
216
3 41214
111...L
A1
102
A2
RELAY
N
LOCK
1 32 45
939480C32/DC24VD
+A1
102
A2
RELAY
..D ..L
C32D
5
6A 250V AC1 AgNi
8934 32
3111
24 2257
216
3 41214
111
MAXMIN
EC-11 10A400V
10A300VListed10A
400V
029 8 7 5 3 4
34 32 24 22 14 12
10
A2
11 6 1 2
31 21 11 A1SD-1W
5789
11 1610 2
3 4
A2 31 21 11 A1
121422243234
04
210
6 54
3
78
9
11 1
SW
ISS
C11A
10A
250
VA
10A400VA
CONNECTOR C-A2
38
75
38
3230
C-A2
204
Clip HF-32
224
Clip HF-32
DC≤10%
RailwayD/R
24, 36, 110C31D/R DC ..... V
24, 36, 110C32D/R DC ..... V
51
= Type “L” (option)
3-pole Industrial Relay accordingto IEC 67-1• lockable manual operation• mechanical flag indicator
Test voltage: 2500V 1500V Tamb. operation/storage:-40..+70/-40..+85°C
Connection No. on socket
Designation according to DIN/EN 50011
Connection on socketsEC-11, C11A, C12B
= contact opening < 3mm
Data at Tamb. =20°C (standard coil )
Contact materialSwitching power AC1/DC1Peak inrush powerSwitching cycles mech. /electr.(AC1)
Operation voltage AC50Hz/DCPower consumptionTriggering delay / release time
Power Relay Control Relay
Option L = with
UniversalPower Relay 10Awith 3 power changeover-contacts this is the robust relayfor AC and DC circuits rangingfrom 10mA10V.
Relay like ..C31, butwith twin contacts 6AThe control relay with highestswitching reliablility for controland signal circuits rangingfrom 1mA 5V.
Ordering example
• Relay C31/AC230V• Socket EC-11 or C11A
• Retaining clip HF-32 (option)
WH
: 35
x35
and others:www.comat.ch
For suitable coil wiringssee “R-modules” page 31
System socket C11A *)
Economy socket EC-11
*) with plugged-inneutral conductorconnector C-A2(standard delivery).
The railway-relays C31D/R DC complyto fire protection standards accordingNFF 16101/2 and ISO 9125/2.
THE UNINDESTRUCTIBLE ONES
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.30 KAT
2008COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
10A 250VA10mA12V
EC-11 10A400V
10A300VListed10A
400V
029 8 7 5 3 4
34 32 24 22 14 12
10
A2
11 6 1 2
31 21 11 A1SD-1W
5789
11 1610 2
3 4
A2 31 21 11 A1
121422243234
04
210
6 54
3
78
9
11 1
SW
ISS
C11A
10A
250
VA
10A400VA
CONNECTOR C-A2
38
75
38
3230
C-A2
204
Clip HF-32
224
Clip HF-32
C33 C34 C39
AgCdO2500VA/...300W40A(16ms)20x106 / ≥ 105
0,8...1,15UN
1,3VA/0,55W15/25ms
AgNi1250VA/...200W20A(16ms)20x106 / ≥ 105
0,8...1,15UN
1,3VA/0,55W15/25ms
Ag-alloy1250VA/...150W10A(20ms)50x106 / ≥1,5x105
0,8...1,2UN
0,25W8/12ms
C33 / AC ..... V
C33 / DC ..... V
24, 48, 115, 230
12, 24, 48, 110
C34 / AC ..... V
C34 / DC ..... V
24, 48, 115, 230
12, 24, 48, 110C39 / DC ..... V
12, 24, 48DC≤10%C39
AC50/60Hz
11
5A 250VA1mA 6V
5A 250VA1mA100mV
458
+
379
10 11A2 2 A1 1 A1
6 1 2
z
1 11211
2 1
1 121 142 122 14
+
48
+
39
10 11A2 2 A1 1 A1
6 1 2
z
1 11211
2 1
1 121 142 122 14
+
57 458
+
379
10 11A2
6 1 2
z
2 A13 A1 1 A1
2 13
1 131 142 132 143 133 14
++
C33,34,39Long Life
N 10 1
3 4
11
89 57
26
R2 R1
relay
04
C33 / AC230VA
10A
250
VA
relay C34 / AC 230VA
04
N 10 1
3 4
11
89 57
26
R2 R1
5A
250
VA
05+216+
R1R2R3
+10 11
relay
3 47 59 8
5A
250
VA
C39 / DC24VD
MAXMIN
51
Ordering example
Relay C34/AC230VSocket EC-11 or C11A
Retaining clip HF-32 (option)
Control andSignal Relay
Power Relay Control Relay
Double-channelPower Relay 10AWith 2x1 power changeover-contacts this is a robust relayfor AC and DC circuits rangingfrom 10mA12V.Width per channel: 17,5mm.
Triple-channelTwin Contact Relay 5Awith 3x1 No contact it is idealfor interface applicationsranging from 1mA 100mV.LED display for each channel.Width per channel: 11,7mm.
Relay like C33, butwith twin contacts 5AThe control relay with highestswitching reliablility for controland signal circuits rangingfrom 1mA 6V.Width per channel: 17,5mm.
2- and 3-channel Industrial Relaysaccording to IEC 67-1• Single or twin contacts• Front contact inspection window or
LED display (C39)
Test voltage: 2000V 2000V Tamb. operation/storage:-25..+60/-40..+85°C
Connection No. on socket
Designation according to DIN/EN 50011
Connection on socketsEC-11, C11A, C12B
= contact opening < 3mm
Data at Tamb. =20°C (standard coil )
Contact materialSwitching power AC1/DC1Peak inrush powerSwitching cycles mech. /electr.(AC1)
Operation voltage AC50Hz/DCPower consumption per channelTriggering delay / release time
*) with plugged-inneutral conductorconnector C-A2(standard delivery).
WH
: 35
x35
2x3x
2x
Economy socket EC-11
System socket C11A *)
and others:www.comat.ch
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice. 31 KAT
2008
Indu
stria
l Rel
ays
1
Industrial Relays
Time Cubes and Relay Modules
t RSK
t t t RSB
t RSE
t RSA
t
WRS
Delay functions
On delay
S ⇒ R on with delaySOFF ⇒ R off
One shot leading edge
S ⇒ R on for tSOFF ⇒ R off(pulse clipping)
Shot timing modes
Pulse shaping
S (pulse or continuous contact)⇒ R on for tS no influence on R and t
Pulse shaping
S ⇒ R on/off periodicallyaccording to tSOFF ⇒ R off
Blinker, pulse start
Blinker functions
S ⇒ R onSOFF ⇒ R off with delay
Off delay
Timing Functions (0,2s-30min)Comat products comply with different international stand-ards and are certified ac-cordingly.
A detailed list can be found on our web page:
www.comat.ch
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.32 KAT
2008COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
S+
A1A2
S
+
A1A2 B1
S+
A1A2 B1
<108 11
9
4 1
35
6 7
14 3 5 86 7 119
SCT3
RELAY
+
B1
210A1A2
Socket
275 8
6
S
4 1
3
RELAY14 3 5 8 6
CT2
+
B1
27A1A2
Socket
E
W
B
A
K W
CT.. -W30 / ...
CT .. - E 30 / ...
CT .. - A30 / ...
CT .. - K30 / ...
CT .. - B30 / ...
0,2s-30min0,2-3s/min • 2-30s/min
EC-11 10A400V
10A300VListed10A
400V
029 8 7 5 3 4
34 32 24 22 14 12
10
A2
11 6 1 2
31 21 11 A1
38
3230
SLH
SLMU
SLMU
SLH
SLH
UC
180
-265
V
UC
90-1
50V
UC
90-2
65V
UC
20-6
5V
DC
9,5
-18
V
6 5 4 3
24 22 12 14
7 8 1 2
A2 21 11 A1
EC-8 10A400V
10A300VListed10A
400V
02
62
38
0,2s-30min0,2-3s/min • 2-30s/min
EC-11EC-8
UCAC/DC
DC10%
CT2/CT38 11
ON OFF
t RS
K
t t t RS
B
tW RS
t RS
A
t RS
E
MAX 10A 250VA
25 422
Clip
CT2/3
For Relay*C21...C39
For RelayC2...C3
S3-CT
58 (51*)
HF-33
Plug-in Time Cubes
8-/11-pole Plug-in Time Delay Relay SystemThe simplest time delay relay sys-tem world-wide, fitting all 8 or11-pin relay sockets (octal /sub-magnalite).Original time cubes® are simply placed between socket and relaywithout rewiring.In this way, even as a retrofit, all industrial relays can be providedwith the required timing functions without additional space beingrequired. The contact connections of the relay on the socket remainthrough-connected.
Function
Order no.
CT2 (8-pin) CT3 (11-pin)
Industrial relay
Time cube®
All new types ..30 (0,2s-30min) are fully compatible with allprevious types ..20, ..21 and ..25.
Triggering
Industrial relay Socket
2 = 8 -pole3 =11-pole
Time cubes CT2-E30/HSocket EC-8 or CS-8
Relay C2-...
Time cubes CT3-E30/HSockel EC-11 oder C11A
Relay C3-...
Ordering example
Time Cubes
Blinker, pulse start
Pulse shaping
One shot leading edge
Off delay
On delay
S ⇒ R on/off periodicallyaccording to tSOFF ⇒ R off
S (pulse or continuous contact)⇒ R on for tS no influence on R and t
S ⇒ R on with delaySOFF ⇒ R off
S ⇒ R onSOFF ⇒ R off with delay
S ⇒ R on for tSOFF ⇒ R off(pulse clipping)
S = TriggeringR = Output circuit⇒ = switches...
and others:www.comat.ch
SIMPLY PLUGED
BETWEEN
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice. 33 KAT
2008
Indu
stria
l Rel
ays
1
31 2 4 5
C12 B
31 21 11
121422243234
5789 3 4
10A
250
VA
SW
ISS
65
4
3
7
8
9
210
04
11 110A
400VA
A2 A1B1
11 16 1210 2
210
A2 A112
210
A2 A1
6k810
A2 A1
210
A2 A1
150k 2
0,1µF470E10
A2 A1
2
0,47µF47E10
A2 A1
2
10k
0,47µF47E10
A2 A1
20,1µF470E10
A2 A1
2
47E12
10
A2
2
A1
22k
0,47µF47E10
A2 A1
2
47E
10
A2 A1
2
6k8
10
A2 A1
2
15k
10
A2 A1
2
A16k8
10
A212
2
47E12
10
A2
2
A1
6k8
10
A2
2
12 A1
RCL1/AC110-240Va
RL1/UC12-24Vu
RCL1/UC48Vu
RCL1/UC24Vu RDL1/DC12-24Vd RDL2/DC12-24Vd RDL3/DC12-24Vd
RDL1/DC48Vd
RL1/AC110-240Va
RC1/UC110-240Vu RD2/DC12-220VdRD1/DC12-220Vd RD3/DC12-220Vd
RC1/UC12-48Vu
+N L N( )/
(+)L + ++
38 38
/
CONNECTOR C-A2
31 2 4 5
31 21 11
121422243234
5789 3 4
10A
250
VA
SW
ISS
65
4
3
7
8
9
210
05
11 1
A2 A1
11 1610 2
10A400VAC11A
CONNECTOR C-A2
RDL1 / DC48VD
2
15k1N4007 1000V 1A
02
4 20
75
C-A2
11R-Module
System socket C12BSystem socket C11A
With additional diode out-put (12), e.g. for collec-tive alarm messages.
With additional diode input(12), e.g. as logical addi-tion.
Illuminated displays
Relay modules indicate the relay’s switch mode and/or help limiting cutoff voltage peaks in the controlcircuit by means of a diode or a RC module.The types R..2/3 are equipped with additional diodes for signal or OR-circuits.For parallel or serial connections the relay modules are simply plugged info the sockets C11A or C12B.
Suppressing units withilluminated displays
Suppressing units
Jack on the socketPlug pin on theR-module
R-module R-module
Ordering example
Module RCL1/UC48VSocket C11A
Relay Type C3-...Clip S3-C (option)
Industrial relay
Relaycoil
System socket C11A System socket C12B
Plug-in coil wirings for 3-pole Industrial Relays C3, C31 and C30
Current types
Triggering
see RL1/UC...V
see RC1/UC...V
Module section
Clip S3-C
Module section
Module sectionModule section
Module section
Plugged-inneutral conductorconnector C-A2(C11A standarddelivery).
Supplementaryproducts
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.34 KAT
2008COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
Notes
Lloyd’s; IEC 61810; EN 60974
Comat products comply with different international standards and are certified accordingly.
A detailed list can be found on our web page:
www.comat.ch
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice. 35 KAT
2008
Indu
stria
l Rel
ays
1
Industrial Relays
DIN Relays
1
2
2x 1
3x 1
CR16 CRS1C C103.06C103.01
C133.01 CR23 CR11
C203.01 CR33 C203.04 C203.06
C301.04
6A5A3A2A1A
10mA1mA100µA
DIN Relays Recommended application
twin contacts
Step
ping
sw
itch
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.36 KAT
2008COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
CR16CX CR23A
AgNi1500VA/...180W15A/20ms30x106 / ≥ 1,5x105
AC –20%+10%/DC ±15%2,5VA/0,25W10ms /20ms
Ag-alloy/Au3 m750VA/...90W—20x106 / ≥ 1,5x105
— /DC ±20%0,25W6ms /4ms
CRS1C
CRS1C / DC ..... V
CRS1C / AC ..... V
CR11C / DC ..... V
CR11C
13 131414
21
A2A1 A11 2
A2
++
13 1414141 2
3
A2A1 A11 2
3 A1
++
12 222414
11 21
A221A1
11+
2x / 3x
111214
12
A2 A1
+( DC-
vers
ion)
1413
A2 A1
+( DC-
vers
ion)
111214
12
A2 A1
+( DC-
vers
ion)
01
CR 23A CR33A / DC..... VCR16AX CR16CX / DC..... V
CR16AX CR16CX / AC ..... V
13mm
CR16AX CR33A
13
45
44 11
90
BS13-KBS13-G(incl.paper)
Ag-alloy/Au5 m65VA/...30W—200x106 / ≥ 105
— /DC ±25%0,25W3ms /4ms
AgNi1500VA/...180W15A/20msDC:10x106; AC:105 / ≥ 105
AC ±15%/DC ±15%2VA/1,5W
AC50/60Hz
DC≤10%
6A 250VA10mA 12V
3A 250VA100 A 100mV
1A 250VA100 A 10mV
6A 250VA10mA 12V
24 24 24 24
230
CR.. DIN
230
MAXMIN
Ordering example
RelayCRS1C/AC230V
Step-on/Step-offRelay
Power Relay Control Relay Signal Relay
Contact materialSwitching load AC1/DC1Peak inrush powerSwitching cycles mech. /electr.(AC1)
Operation voltage AC50Hz/DCPower consumption AC/DCTriggering delay / release time
Connection
Recomm. triggering time ≥ 50ms
Data at Tamb. =20°C
z = contact opening < 3mm
DIN Interface
and others:www.comat.ch
DIN Interface Relais• No external coil wiring required• Mounting on DIN rail TS 35
Test voltage: 2000V 2000V
Tamb. operation/storage:-20..+60/-40..+85°C
WITHOUT BASE
Power Relay13mm series, 1 x NO resp.1 x CO up to 6A.Integrated LED and coil wiring.
Control Relay (Signal relays)13 mm series, 2/3 channel,each 1 x NO Au twin contact.Recommended max. load200mA/24V resistiv.Integrated LED and coil wiring.
Signal Relay13mm series,1 channel,2 x CO Au twin contact.Recommended max. load200mA/24V, resistiv.Integrated LED and coil wiring.
Stepping Relay13mm series, 1 x CO suitablefor permanent energizing.Supply loss safe.Integrated LED and coil wiring.
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice. 37 KAT
2008
Indu
stria
l Rel
ays
1
6A 250VA10mA 24V
C203.04 C301.04 C103.06 C203.06C103.01 C133.01 C203.01
752,
5
17,54,2
LABEL
UC/
2x 2x
C103.01
C103.01
C103.01
110-127, 220-240
12C133.01
C133.01
C133.01
C203.01 / DC ..... V
C203.01 / AC ..... V
C203.01 / UC ..... V
12-15, 24, 48C203.04 C301.04 / DC ..... V
110-127, 220-240
12C103.06
C103.06
C103.06
C203.06 / DC ..... V
C203.06 / AC ..... V
C203.06 / UC ..... V
5 64
1 2 3
A2 A2 A2
A1 A1 A1
14 14 14
13 13 13
2
2
1
1
A1 A1 A2
141211
141211
2
1
141211
141211
21
A1 A1 A2
21
A1 A1 A2
1
141211
141211 141211
2
A1 A2
141211 141211
141211
21 22 24
A1 A2A1 A2
141211
AgNi1500VA/...300W15A/20ms20 x106 / ≥ 105
0,85...1,15UN
≤ 0,6W ≤ 1,7W 2x ≤ 0,6W10ms /10ms
AC50/60Hz
DC≤10%
C103
C103
5A 250VA1mA 0,1V
2A 125VA10 A 10mV
C100...300 DIN
MAXMIN
3x 2x
24, 36, 48 24, 36, 48
RelayC301.04/DC24V
Ordering example
Power Relays Control Relays Signal Relays
Contact materialSwitching load AC1/DC1Peak inrush powerSwitching cycles mech./electr.(AC1)
Operation voltage AC50Hz/DCPower consumption AC/DCTriggering delay / release time
Connection
z = contact opening < 3mm
Data at Tamb. =20°C
DIN Interface
and others:www.comat.ch
DIN Interface Relay• No external coil wiring required• Mounting on DIN rail TS 35
Test voltage: 2000V 2000V
Tamb. operation/storage:-20..+60/-40..+85°C
Ag-alloy1250VA/...150W10A /20ms50 x106 / ≥ 1,5 x105
0,8...1,2UN
0,25W (per channel)6ms /30ms
Ag-alloy/Au3 m250VA/...60W—100 x106 / ≥ 105
0,8...1,2UN
0,25W (per channel)10ms /20ms
Power RelayDIN series 17,5mm, 1/2 channels with1/2 x CO contacts up to 6A.Integrated LED and coil wiring.
Control RelayHigh efficient 2/3 channel control relayDIN series 17,5mm, each 1 x CO resp.1 x NO twin contact.Multi-layer contact up to 5A.Very versatile in application.Integrated LED and coil wiring.
Signal RelayDIN series 17,5mm,1/2 channel each 1 x CO Autwin contact.Recommended max. load200mA/24V.Integrated LED and coil wiring.
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.38 KAT
2008COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
Notes
Lloyd’s; IEC 61810; EN 60974
Comat products comply with different international standards and are certified accordingly.
A detailed list can be found on our web page:
www.comat.ch
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice. 39 KAT
2008
Indu
stria
l Rel
ays
1
Industrial Relays
Solide-State Relays
1x Triac
2x Triac
1x PNP
2x PNP
3x PNP
1+1 PNP
1x co PNP
C35 KA115 KA108
KA208 C36
C37 KD125 CPF11 CTV11
C38 KD215 CPF22
KD315 C301.08C311.08
KDM3-24
KDW3-24
5A3A2,5A2A1,5A1A
800A250mA30mA10mA5mA2mA1mA
Solide-State Relays Recommended application
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.40 KAT
2008COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
C35 C36 C37 C38
15A /1s≤0,2V≤100 A≤70A /150 s
110-240V 24-48V40..60Hz 40..400Hz≤ 5mA ≤ 6mA≤ 30ms ≤ 20ms≤ 30ms ≤ 30ms
1,5A /1s≤3V≤100 A≤12A /200 s
110-240V 24-48V50..60Hz 40..400Hz≤ 35mA ≤ 20mA≤ 20ms ≤ 20ms≤ 80ms ≤ 80ms
8A /20ms≤1,5V≤3mA—
110-240V 24V50..60Hz 50..60Hz≤17mA ≤ 12mA≤ 30ms ≤ 30ms≤ 40ms ≤ 80ms
15A /1s≤0,2V≤100 A≤70A /150 s
110-240V 24-48V40..60Hz 40..400Hz≤ 5mA ≤ 6mA≤ 30ms ≤ 20ms≤ 30ms ≤ 30ms
2x
210
5 3
A2 A1
13 147
+
2kV
+
+RL
1 14
10
+
21
9
6
7
+
3
12 2kV 2kV
A2 A22 A1 1 A1
135
+2 14
RL
+RL
2
+
10
43
A2 A1
14 13
2kV
+RL
C35 / AC ..... V
C35 / UC ..... V
110-240
24-48
C36 / AC ..... V
C36 / UC ..... V
110-240
C37 / UC ..... V24-48, 110-240
C38 / UC ..... V24-48, 110-240
AC50/60Hz
UC/
11
SD-1W
5789
11 1610 2
3 4
A2 31 21 11 A1
121422243234
04
210
6 54
3
78
9
11 1
SW
ISS
C11A
10A
250
VA
10A400VA
CONNECTOR C-A2
38
75
C-A2
204
Clip HF-32
EC-11 10A400V
10A300VListed10A
400V
029 8 7 5 3 4
34 32 24 22 14 12
10
A2
11 6 1 2
31 21 11 A1
38
3230
224
Clip HF-32
10 21
49
6
8 3
12
A2 2 A1 1 A1
2 14 2 13 1 14 1 13
RL RL
N
L
N
L
2kV
1 A11+2
0,8A 20...265VA30mA 10V
5A 10...32VD1mA 5V
2A 10...32VD1mA 5V
0,8A 10...265VU1mA 10V
C35...C38
210
0,8A 265VU
04
3 4
Solid-State
relay C35/AC110-240VA
N
K 0,8A 265VA
04
3 4
2Solid-State
9 8
1610 N
R1R2
relay C36/AC110-240VA relay C37/UC110-240VU
05
DC10-32Vd
PNP 5A
Solid-State
+
7 5 3
RL
10 +2
K
relay
05
DC10-32Vd
PNP 2A
Solid-State
K
3
R1
9 7 5
+
R2
110 +6 +2
RLRL
C38/UC110-240VU
24
1x 2x1x
MAXMIN
51
Data at Tamb. =20°C
Universal Solid-State Relay
DC Solid-StateRelay
1- and 2-channel Solid-state Relayaccording IEC67-1• LED display for each channel• operation voltage range 0,8..1,1UN
• galvanically decoupled control (2kV)
Tamb. operation/storage:-25..+60/-40..+85°C
Peak inrush powerVoltage dropResidual currentShort-circuit proof K
Control voltageFrequency rangeControl currentTriggering delayOff delay
Ordering example
Relay C37/UC110-240VSocket EC-11 or C11A
Retaining clip HF-32 (option)
Connection No. on socket
Designation according to DIN/EN 50011
Connection on socketsEC-11, C11A, C12B
Universal Solid-StateRelay for AC or DC loadHighest switching frequencyvirtually limitless due to solid-state operation.No external protective wiringrequired.
AC Solid-State Relaydouble-channelTriac output, crossover switch-ing. Built-in RC wiring protec-tion.Especially for bulb-loads andhigh switching frequencies.• Minimum load: 30mA
DC Solid-Statesingle-channelBounce-free and non wearingfor DC loads (inductive/capacitive).Short-circuit /overload proof.No external wiring protectionrequired.
DC Solid-State Relaydouble-channelConstruction, characteristicsand application like C37,but double-channel.2A constant current perchannel.
WH
: 35
x35
*) with plugged-inneutral conductorconnector C-A2(standard delivery).
Economy socket EC-11
System socket C11A *)
DC Solid-StateRelay
AC Solid-StateRelay
Solid-State
and others:www.comat.ch
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice. 41 KAT
2008
Indu
stria
l Rel
ays
1
KA108 KA115 KA208
KA108/DC12-24V
KA115/UC12-24V
KA208/DC12-24V
8A (20ms)3mA50/60Hz≤1,5V
DC10...30VdUA1: 6V12ms10mA (24V)
20A (20ms)3mA50/60Hz≤1,5V
UC10...30VuUA1: 6V12ms10mA (24V)
8A (20ms)3mA50/60Hz≤1,5V
DC10...30VdUA1: 6V12ms10mA (24V)
2x
R B B
UCA40-400Hz /
DC≤ 20%
8
+
75
14
6
2
+
3
12 2kV 2kV
A2 A22 A1 1 A1
2 14 2 13 1 14 1 13
7
+
8
13
A2 A1
14 13
2kV
7
+
8
13
A2 A1
14 13
2kV
0,8A 20...265VA30mA
1,5A 20...265VA30mA
0,8A 20...265VA30mA
22,5
30
S7-P
2
4
6
8
1
3
5
7
2
4
6
8
1
3
5
7
10
0,6
7,25
5,9
4,7
ø 2,2
14,513,15,2
RC-G
0,5
x2
21
1324
11
8 756B1A2 A1
24 1222 14
2
4
6
8
1
3
5
7CS-18
BClip GC-T *)
Clip RC-G
Clip GC-W *)
35,5223
R
22 x 65
22 x 28
22,5
75
01
+78
1
2kV
3L1
30m
A...
0,8
A A
C20
-265
VA
KA10
8/D
C12-
24VD
rela
y
30mA..1,5AAC20-265VA
+78
1
2kV
3L1
KA115/UC12-24VUrelay
01 01
30mA..0,8AAC20-265VA
+75
14
6
2
2kV
+
L13
L1
12
8
KA208/DC12-24VDrelay
KA
35,5
1x1x
MAXMIN
UniversalAC Solid-State Relay1-channel, 0,8A/AC240V.Triac output with RC wiringprotection.DC Triggering 12...30Vgalvanically isolated.
UniversalAC Solid-State Relay1-channel, 1,5A/AC240V.Triac output with RC wiringprotection.Triggering galvanicallyisolated.
UniversalAC Solid-State Relay2-channel, 0,8A/AC240V(2x0,5A).Triac outputs RC wiringprotection.Width per channel: 11mm.Triggering galvanicallyisolated.
AC Solid-State Relay• 1- and 2-channel• crossover switching• each channel indicated by LED• Triggering/Output 2kV
Tamb. operation/storage:-25..+60/-40..+85°C
Data at Tamb. =20°C
Connection No. on socket
Designation according to DIN/EN 50011
Connection with socketCS-18
Peak inrush powerResidual currentFrequency rangeVoltage drop
Control voltageTriggering OFFSwitching delayControl current
Relay KA115/UC12-24VSocket CS-18 or S7-P
Retaining clip RC-W (option)
Ordering example
Case Case Case
Socket for printed circuit mounting S7-P
Case
Case
*) Standard delivery with relay (Case B)
System socket CS-18
View onsolder side
Solid-State
WH
:G
eh.R
: 22
x28
Geh
.B: 2
2x
65
AC Solid-StateRelay
AC Solid-StateRelay
AC Solid-StateRelay
and others:www.comat.ch
SOLID - STATE
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.42 KAT
2008COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
6-12, 12-24KD125 / DC ..... V KD215/DC12-24V KD315/DC12-24V
4
8 7
+
1
6
25k
K K
1214
A2 1 A1+
2 A1+
2 13 1 13
KD125 KD215 KD315
3x2x
R BR
DC≤ 20%
4
75
5k
+
3 1
6
25k
8
K K K
13214
A2 1 A1+
2 A1+
3 A1+
2 13 3 13 1 134
8
+
5k
7
1
K
3
A2 A1+
14 13
02
KD12
5/D
C12-
24VD
rela
y
5k
RL
1
8
4+
+7
PNP
2
,5A
K
01
+76
RL
5k
124+
8
2 1
PNP
2
,5/2
x1,5
AK
+KD21
5/D
C12-
24VD
rela
y
01
KD315/DC12-24VDrelay
+ 75
RL
5k
134+
8
3 1
6
2
2
RL
5k
+
PNP 2,5/3x1,5AK
2 3 1
22,5
30
S7-P
2
4
6
8
1
3
5
7
2
4
6
8
1
3
5
7
10
0,6
7,25
5,9
4,7
ø 2,2
14,513,15,2
RC-G
0,5
x2
BClip GC-T *)
Clip RC-G
Clip GC-W *)
35,5223
R
22 x 65
22 x 28
21
1324
11
8 756B1A2 A1
24 1222 14
2
4
6
8
1
3
5
7CS-18
22,5
75
35,5
KD
2,5A 10...32VD1mA 5V
1,5A 10...32VD1mA 5V
1,5A 10...32VD1mA 5V
1x
15A (20ms)<100 A50m
DC 5...18V/10...32VdUA1-2: ≤3V/≤6V2,5ms4mA (24V)
15A (20ms)<100 A50m
DC 10...32VdUA1-2: ≤3V/≤6V2,5ms4mA (24V)
15A (20ms)<100 A50m
DC 10...32VdUA1-2: ≤3V/≤6V2,5ms4mA (24V)
MAXMIN
AC Solid-State Relay• 1- and 3-channel• overload/short-circuit proof K
• limiting inductive voltage• each channel indicated by LED• Triggering/Output 2kV
Tamb. operation/storage:-25..+60/-40..+85°C
Solid-State Relay likeKD125, but 2-channel2,5A/2x1,5A/DC24V.Width per channel: 11mm.With thermal overloadprotection and short-circuitresistent.
Short-circuit proofuniversal DC solid-stateRelay 1-channel2,5A/DC24VWith thermal overloadprotection and short-circuitresistent.
Solid-State Relay likeKD125, but 3-channel2,5A/3x1,5A/DC24V.Width per channel: 7,3mm.With thermal overloadprotection and short-circuitresistent.
OutputCurrent peakResidual currentON-resistance
Control voltageTriggering OFFON-OFF-switching delayControl current
Connection No. on socket
Designation according to DIN/EN 50011
Connection with socketCS-18
Data at Tamb. =20°C
Relay KD215/DC12-24VSocket CS-18 or S7-P
Retaining clip RC-G (option)
Ordering example
1PNP (noc) 2x1PNP (noc) 3x1PNP (noc)
Case Case Case
Socket for printed circuit mounting S7-P
Case
Case
*) Standard delivery with relay (Case B)
System socket CS-18
View onsolder side
WH
:G
eh.R
: 22
x28
Geh
.B: 2
2x
65
Solid-State
DC Solid-StateRelay
DC Solid-StateRelay
DC Solid-StateRelay
and others:www.comat.ch
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice. 43 KAT
2008
Indu
stria
l Rel
ays
1
KDM3-24
B
22,5
30
S7-P
2
4
6
8
1
3
5
7
2
4
6
8
1
3
5
7
10
0,6
7,25
5,9
4,7
ø 2,2
14,513,15,2
RC-G
0,5
x2
KDM3-24
3A (5A) 24Vd10mA 10V
Q3
01
KDM3-24/DC12-24VDrelay
+7
134+
6
2
8
M
Q2 Q1
E1
K 3A,12-24VD
35,5
DC≤ 20%
FET PNP3A (5A) / 10-32V...100W20A / 1s<100m<100µA<1ms
9-28V400mW / DC24V
FET NPN3A (5A) / 10-32V...100W20A / 1s<100m<100µA<1ms
21
1324
11
8 756B1A2 A1
24 1222 14
2
4
6
8
1
3
5
7CS-18
22,5
75
Clip GC-T *)
Clip GC-W *)
35,5223
65
+E1
4
7568
132Q3+ Q2 Q1
K
K
K 3A,12-24VD
M
+
7
2 3 1
68
4
S
KDM3-24/DC12-24V
+PNP NPN
MAXMIN
Interface Modulefor PLC’s and control systems with one PNP power contact andone NPN brake contact.For DC motor controls with brake function.The contacts are overload- and short circuit protected.
Connection No. on socket
Designation according to DIN/EN 50011
Connection with socketCS-18
Data at Tamb. =20°C
Interface moduleKD215/DC12-24VSocketCS-18 or S7-P
Retaining clip RC-G (option)
Ordering example
Case
Socket for printed circuit mounting S7-PSystem socket CS-18
View onsolder side
WH
: 22
x65
Contact typeSwitching current /voltageSwitching power DC1Peak inrush currentContact resistanceLeakage currentTrigg. delay/ release time
Operation voltage activePower consumption Pmax
Power contact Break contact
*) Clip GC-T + GC-WStandard delivery with KDM
Adjustment braking action
Solid-State
DC-Motor Control Relay
and others:www.comat.ch
Motor Control Relay• For controlling and braking of DC Motors
Tamb. operation/storage:-25..+60/-40..+85°C
TO CONTROL AND
BRAKE DC MOTORS
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.44 KAT
2008COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
KDW3-24
KDW3-24
3A (5A) 24Vd10mA 10V
SWISS MADE BY COMAT
+
KDW3-24/UC24-240V
A1
3A
, 12
-24
VD
A2
Q1 Q2
01
K
K
(+) ( )
+ Q1 Q2
A1 A2
FET PNP3A (5A) / 10-32V...72W (160W)20A / 20ms<50m<100µA<5ms
18-255V AC/DC3-8mA / <400mW
UC50/60Hz /
752,
5
17,54,2
LABEL
TS
35
5 64
Q1 Q2
A2A1
K
K
+
+
A1 A2
Q1 Q2RL2 RL1
+
DIN 1x co
KDW3-24/UC24-240V
MAXMIN
Interface ModuleSolidstate relay with 1x CO output PNP for 3A, 24VD.The contacts are overload- and short circuit protected K .LED status display.Galvanical isolated output.This relay is specially recommended as an alternative to electro-mechanical relays for applications with high switching cycles.Bounce-free switching.
Contact typeSwitching current / voltageSwitching power DC1Peak inrush currentContact resistanceLeakage currentTrigg. delay / release time
Operation voltage activePower consumption Pmax
Connection
Ordering example
Interface moduleKDW3-24/UC24-240V
Data at Tamp = 20°C
Solide-State Changeover Relay
Solide-State
and others:www.comat.ch
Solid-State AC/DC Relay• Change over PNP for all inductive loads• Mounting onto DIN rail TS 35.
Test voltage: 2kV
Tamb. operation/storage:-25..+60/-40..+85°C
CHANGE OVER WITH
SEMI CONDUCTOR
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice. 45 KAT
2008
Indu
stria
l Rel
ays
1
+
A2 A2
K K K
2 31A1 2A1 3A1
1 5k
3O2O1O
+ + +
C301.08 C311.08
3x
I-0 = 2kV
C301.08/DC24VDC
≤10%
CTV11
CTV11/DC5-60V
21 3
1A1
A2
2A1 3A1
A2
2kV
K K K
3O2O1O
+ + +
+
0,75A (20ms)<100zA<1V
EH 15-60V / EL 5-15V≤10% @10VEL ≤ 2,5V / EH ≤ 5VTyp. 10mAON 200zs / OFF 400zs
3x
752,
5
17,54,2
LABEL
5 64
CTV11
CTV11
+
E
K
RL
O
PNP
12-65V
EL
4-18V
EH ++
250mA
5-65V
2kV
C311.08/DC24V
(A)
5
2
10 50ton(%)100
ton toff
t ≤ 2s
15A (20ms)<100zA50m
DC24V (10...30V)D≤10% @10VUA1: ≤ 6V4mA @ 24V2,5ms
15A (20ms)<100zA50m
DC24V (10...30V)D≤10% @10VUA1: ≤ 6V4mA @ 24V2,5ms
CTV, C300 DIN
250mA 5...60 VD1mA 10V
2A 10...30 VD1mA 10V
2A 10...30 VD1mA 10V
MAXMIN
Solid-State Relay
Admissible peak currentResidual currentVoltage drop / ON-rheostat
Control voltage (Unom)Ripple Triggering OUTControl current on A1Swtiching delay
Note on use C300The 3 channels can be connected parallelin any desired arrangement ( Imax.=6A).The outputs are self-resetting afterthermal overload.Self-resetting after short-circuit(>17A/150zs): Triggering OFF.
Steady load
Limit load diagram (resistive load)
Ordering example
Solid-state relayC301.08/DC24V
Switchingamplifier
Connection
Data at Tamb. =20°C
Solid-State
Solid-State Relay Solid-State Relay
and others:www.comat.ch
Solid-State Relaywith galvanically isolatedtriggering input to control andswitch DC loads.1 channel 250mA/DC5-60V
Compact 3-channelSolid-State Relayfor the switching of DC loadsup to 2A/DC 24V.Outputs, galvanically isolated.Overload and short-circuitproof. Specially suitable forhigh switching cycles.(PLC and ancillery)
Compact 3-channelSolid-State Relaylike C301.08 but withoutgalvanic isolation of outputs.
1- and 3-channel DC Solid-State Relay• for high switching cycles• galvanical separation 2kV• mounting onto DIN rail TS 35
Tamb. operation/storage:-25..+60/-40..+85°C
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.46 KAT
2008COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
CPF22CPF11
DC≤10%
15…32V
E1
SPNP
CPF
+ +19…28V
E1
SNAMUR
CPF
E2+ +
CPF11/DC24V CPF22/DC24V
TS
35
5 1064
8
CPF22
CPF11
752,
5
17,54,2
RS
t RS
t RS
t
K L A K A
ALK
11K
PNP
1S
1RL
2E21E21E1 2E1
1O 2O
5K6
2S
+ 2RL
150mA
+
4kV
10÷45VD
15÷32VD
+
+FD
E1
+E2
O
3K3
K
PN
P
S
RL
0,8A
4K7
15÷32VD
+
CPF11,22 DIN 2x
2A 15...32Vd2mA 10V
150mA 45Vd2mA 10V
MAXMIN
Pulse Shaper
Double Channel Pulse Shaper• Input /output galvanically
isolated 4kV• Input and output times
separately settable• 2 functions to choose• LED output display for each channel
• Settable functions:
Single Channel Pulse Shaper• Input reversible (E-E)• Input and output times
separately settable• 3(6) functions to choose• Built-in free wheel diode 1A• LED display for E and O
• Settable functions:
Settable times:input pulse output pulse≥1/5ms 5÷600ms
Settable times:input pulse output pulse≥0,5/2,5ms 50/200ms
Three-wire sensorNAMUR sensor
Example of order
Pulse shaperCPF11/DC24V
Pulse shaping
S (pulse or continuous contact)⇒ R on for tS no influence on R and t
S (pulse or continuous contact)⇒ R on for tS on for t = tRESET
Pulse shaping retriggerable
(subsequ. time operation from 0)
S ⇒ R onSOFF ⇒ R off with delay
Off delay
Pulse Shaper
Solid-State
and others:www.comat.ch
Pulse shaper with timing functionTo stretch respective to limit control pulses.Suitable for NAMUR sensors respective toanalyze fast sequences with high revolutionsand short pulses.
Tamb. operation/storage:-25..+60/-40..+85°C
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice. 47 KAT
2008
Indu
stria
l Rel
ays
1
Industrial Relays
Miniature Contactors
Comat products comply with different international stand-ards and are certified ac-cordingly.
A detailed list can be found on our web page:
www.comat.ch
2
3+1
4
RIC20 RIC-AUX
SOC-6 SOC-2
RIC25 RIC40 RIC63
63A40A25A20A10A6A
10mA5mA1mA
& &
Miniature Contactors Recommended application
twin contacts
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.48 KAT
2008COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
SOC-6-1a
SOC-6-1a / AC ..... V
SOC-6-1a / DC ..... V
24, 230
AgNi11kW 400V // 4kW 400V4kW 9A 400V // –1,9A 400V // 1,5A 400V...300W0,3A 220V // 0,1A 220V90A / 70Aeff20x106
0,8...1,2UN
4,2VA/3W20ms/15ms
AgNi7kW 400V–1,9A 400V...300W0,3A 220V>30A10x106
AgNi7kW 400V–1,9A 400V...300W0,3A 220V>30A10x106
SOC-6
20A // 10A 400VA10mA 24V // 1mA 6V
AgNi7kW 400V–1,9A 400V...300W0,3A 220V>30A10x106
SU-404MSU-422MSU-440M
54 64 74 84
53 63 73 83NO
NO
NO
NO
NO
NO
NO
NO
54 64 72 82
53 63 71 81NO
NO
NO
NO
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
52 62 72 82
51 61 71 81
AC50Hz
DC≤10%
10A 400VA10mA 24V
10A 400VA10mA 24V
10A 400VA10mA 24V
24
SS-1...
13NO5L33L21L1 A1
14NO2T1 A24T2 6T3
ON
13
14
23
24
33
34
43
44
SOC-6-1a/AC230V
20A400Va
531 13E041
4 0
1
10A400Va
A1
50/60Hz 01
O SU-440M
53NO 63NO 73NO 83NO
54NO 64NO 74NO 84NO
01
O
51NC 61NC 71NC 81NC
52NC 62NC 72NC 82NC
SU-404M 01
SS-1BM/UC12-48VU
0µ47 150Ω
A1 A2
01
O
Type:
SR-6O Interlock Unit
SU-4...SS-1...SR-6
44
35
50
57
533 1
5845,4
SOC-6
TS35
13NO5L33L21L1 A1
14NO2T1 A24T2 6T3
13
14
23
24
33
34
43
44
SOC-6
26,2 1
SS-1...
SU-4...
SR-6
6 1
01
O
53NO 63NO 71NC 81NC
54NO 64NO 72NC 82NC
SU-422M
DIN
SU-440M SU-422M SU-404M SS-1HM/UC110-240V
SS-1BM/UC12-48V
MAXMIN
13 +531 A1L1 L2 L3 NO
T1 T2 T3 NO
142 A24 6
13 23 33 43
14 24 34 44
Connection lay out (top/bottom)
Contact materialSwitching power AC1Switching power AC3/4Switching current AC15Switching power DC1Switching power DC13Making-/Breaking capacityMechanical switching cycles
Operation voltage AC50Hz/DCPower consumptionTypical make/ release time
Continuous terminal No.
Designation according to DIN/EN 50011
3-/4-pole Miniature Contactor• All contacts with twin interruption• Manual operation• Mechanical status display
Test voltage: 4000V 4000VTamb. operation/storage: -20..+60/-40..+85°C
Ordering example
Miniature contactorSOC-6-1a/AC230V
•Auxiliary contact block(2NO + 2NC contacts)SU-422M
RC moduleSS-1H/UC110-240V
Interlocking unitSR-6
MiniatureContactor
Additional auxiliary Snap-on contacts RC Modules
UniversalMiniature Contactorwith 3 main contacts 20Aand 1 auxiliary contact 10A(signal twin contact).Contact opening > 3mm andtest voltage 4000V.Specially suitable for “safelyseparation” in low voltagecircuits.
Additional auxiliarycontact block4 NO contacts.Snap-on to miniaturecontactor SOC-6.Expands the SOC-6up to a total of 8 NOcontacts.
Additional auxiliarycontact block2 NO + 2 NC contacts.Snap-on to miniaturecontactor SOC-6.Expands the SOC-6up to a total of 6 NOand 2 NC contacts.
Additional auxiliarycontact block4 NC contacts.Snap-on to miniaturecontactor SOC-6.Expands the SOC-6up to a total of 4 NOand 4 NC contacts.
RC Modulto limit overvoltage.Universal version(UC...VU) for AC andDC coils.Snap-on directly ontominiature contactorSOC-6.
Interlocking unit SR-6mechanically prevents the simultaneousengagement of two parallel workingSOC-6.
Data at Tamb. =20°C / ≤40°CMain contacts // Auxiliary contact
Current consumption:at AC24V : 8mAat DC24V : 4mAat AC230V : 12mAat DC220V: 2,5mA
Release time SOC-6 withRC module ≤45ms
Arrangement
Miniature Contactor
and others:www.comat.ch
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice. 49 KAT
2008
Indu
stria
l Rel
ays
1
AgNi13kW 400V2,2kW 400V20A 24V / 2A 110V100A / 2,5ms
6A 400V6A 24V / 0,5A 220V> 3 x 106
0,8 - 1,2 UN
32W 20ms /1,5W< 20ms / < 20ms
Bestellbeispiel
SOC-2-1a
SOC-2-1a/AC.....V
50 62,5
35 50.5
454,5 1
TS35
4,75
4,1
8
SOC-2
SOC
-2-1
a/A
C23
0VA
14642
13531
I O
AC1
20A
400
V/13
kWAC
3 2,
2kW
/400
V
A2
A1IEC/EN60947-402
50H
z
20A // 6A 400VA10mA 24V // 1mA 6V
24, 230
13531 A1L1 L2 L3 NO
T1 T2 T3 NO142 A24 6
13 23 33 43
14 24 34 44
AC50Hz
SOC
-2-1
a/A
C23
0VA
14642
13531
I O
AC1
20A
400
V/13
kWAC
3 2,
2kW
/400
V
A2
A1IEC/EN60947-402
50H
z
SOC-2-1a/AC230VA
1L1
T12
3L2
T24
5L3
T36
13
14
A1
A2
AC1 20A 400V 13KWAC3 2,2kW 400VEN 60947-4; IEC1095; VDE 0660
02
50Hz
MAXMIN
SOC-2 DIN
Contact materialSwitching power AC1Switching power AC3/4Switching current DC1Inrush current
Switching currentSwitching current DC1Mechanical life time
Coil voltageCoil powerTypical make / release time
Innstallation Contactor SOC-2-1a
Cover sealed
Installation ContactorHigh power relay up to 3x20A 400V and1 auxiliary twin contact 6A.For installation mounting with cover conformDIN 43880.The cover can be sealed.For general applications and motors up to2,2kW.Suitable for pilot control signals.
3- + 1-pol. Miniature Contactor• All contacts with twin interruption• Manual operation• Mechanical status display
Test voltage: 4000V 4000V
Tamb. operation/storage:-20..+55/-30..+80°C
Continuous terminal No.
Designation according to DIN/EN 50011
Connection lay out (top/bottom)
Data at Tamb. =20°C / ≤40°CMain contacts // Auxiliary contact
Cover sealedSOC-2COV
Ordering example
Installation contactorSOC-2-1a/AC230V
Spare parts
Miniature Contactor
and others:www.comat.ch
MINIATURE CONTACTOR
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.50 KAT
2008COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
RIC20 RIC25 RIC40 RIC63 RIC-AUX
20A 400VA10mA 24V
25A 400VA10mA 24V
40A 400VA10mA 24V
63A 400VA10mA 24V
6A 400VA5mA 24V
AgNi20A400V1,3kW/230V4kW/230V6002x105
0,85 - 1,1 UN
2,5W20ms // 20ms
AgNi25A400V2,2kW/400V16kW/400V6002x105
0,85 - 1,1 UN
3W10ms // 50ms
AgSnO240A400V5,5kW/400V26kW/400V1201x105
0,85 - 1,1 UN
5W20ms // 35ms
AgSnO263A400V8,5kW/230V40kW/400V1201x105
0,85 - 1,1 UN
5W20ms // 35ms
AgNi6A400V––6002x105
––– // –
RIC20-200/UC ..... V
RIC20-110/UC ..... V
RIC20-020/UC ..... V
24, 230UCA 50/60Hz / D
24, 230
24, 230
RIC25-400/UC ..... V
RIC25-220/UC ..... V
RIC25-040/UC ..... V
24, 230
24, 230
24, 230
RIC40-400/UC ..... V
RIC40-220/UC ..... V
RIC40-040/UC ..... V
24, 230
24, 230
24, 230
24, 230RIC-AUX20
RIC-AUX11
RIC-AUX02
A1 31
A2 42
A2 R22
A1 R11
R3A1R1
R4A2R2
A1 531 7
A2 642 8
A1 R3R11 3
A2 R4R22 4
A1 R5R3R1 R7
A2 R6R4R2 R8
A1 531 7
A2 642 8
A1 R3R11 3
A2 R4R22 4
A1 R5R3R1 R7
A2 R6R4R2 R8
A1 531 7
A2 642 8
6151
6252
6252
6151
6151
6252
RIC20 RIC25-63
UCA 50/60Hz / D
UCA 50/60Hz / D
TS35
RIC20
17,5 35
RIC25
54.5
RIC40RIC63
85
8
RIC-
AUX
TS35
45
44 (45.5*) 16.55
1.5*
A1 R3R11 3
A2 R4R22 4
RIC63-400/UC ..... V
RIC63-220/UC ..... V24, 230
RIC DIN
MAXMIN
Contactor20A
Contactor25A
Contactor40A
Contactor63A
AUX Block
2NO or 2NCor 1NO/1NC
4NO or 4NCor 2NO/2NC
4NO or 4NCor 2NO/2NC
2NO or 2NCor 1NO/1NC
AC/DC Istallation ContactorsNo noise!• All contacts doublemake/
doublebrake• Mechanical status display
Test voltage: 4kV/3Tamb. operation/storage:-20..+55/-30..+80°C
AuxilaryContactblock with2NO or 2NC or1NO+1NC contacts.For signalling andcontrol applicationsup to 6A with crowntwin contacts.For all RIC contactors.
Contactor 25AContactor with 4NO or 4NCor 2NO+2NC contacts.UC (AC/DC) versions arenoise free and do not needexternal freewheelingcircuits.No coil inrush overcurrent.Sealing cover optional.
Contactor 40AContactor with 4NO or 4NCor 2NO+2NC contacts.UC (AC/DC) versions arenoise free and do not needexternal freewheelingcircuits.No coil inrush overcurrent.Sealing cover optional.
Contactor 63AContactor with 4NO or2NO+2NC contacts.UC (AC/DC) versions arenoise free and do not needexternal freewheelingcircuits.No coil inrush overcurrent.Sealing cover optional.
Contactor 20AContactor with 2NO or 2NCor 1NO+1NC contacts.UC (AC/DC) versions arenoise free and do not needexternal freewheelingcircuits.No coil inrush overcurrent.Sealing cover optional.
Connection lay out (top/bottom)
Contact materialSwitching current ITHSwitching voltageSwitching power AC3Switching power AC1/AC7aOp Frequenz max. cycle/hrElectrical life cycles AC1
Coil voltage rangePower consumptionOperate / release time typ.
Data at Tamb =20°C
Ordering example
Installation contactorRIC25-400/UC230V
Aux blockRIC-AUX20
Sealing coverRIC-SEAL20
*OptionSealing coverType: RIC-SEAL20
RIC-SEAL25RIC-SEAL40-63
4NO or2NO/2NC
and others:www.comat.ch
NO NOISE!
Miniature Contactor
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
51 KAT2008
Tim
e D
elay
Rel
ays
2
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.
• Time Cubes®
• Multifunction Time Delay Modules• Time Delay Relays• Pulse Shapers• Step-on Step-off Relays• Power Relays• Socket• Accessories
Time Delay Relays
52 KAT2008
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.
T
tRESET
t STOP
Test
t RSE
t RSA
FRS
t1 t2
Wt R
S
t RSN
t1t1 t2 RSI
t1t2t1 RSP
t t t RSB
B1
RS
t t t
t1 t2 RSG
t2t1 RSH
t RSK
t RSL
ORS
t1 t2
Stop/Reset
Y St
t -
X1
tt t RSB2M
RS
t
US1/S2
R
P(tP)
tA tV
VS1/S2
R
P(tP)
tA
ON OFF
RS
t t
t2 t1C55,CT1:
S
LS
RS
tt RS
On delay single shot
S (pulse or continuous contact)⇒ R after t1 on for t2S no influence on R and t
On delay single shot
S ⇒ R after t1 on for t2SOFF ⇒ R off
Delayed pulse
S ⇒ R on/off periodicallyaccording to t1 and t2SOFF ⇒ R off
Repeat cycle timer, pulse start
S ⇒ R after t1 (t2) on/off peri-odically according to t2 and t1SOFF ⇒ R off
Repeat cycle timer, interval start
Repeat cycle timer
S ⇒ R on/off periodicallyaccording to tSOFF ⇒ R off
Blinker, pulse start
S ⇒ R on/off periodicallyaccording to tSOFF: last pulse = t
Blinker, pulse start, trailing pulse
Pulse shaping
S (pulse or continuous contact)⇒ R on for tS no influence on R and t
S (pulse or continuous contact)⇒ R on for tS on for t = tRESET
Pulse shaping, retrigger. (subsequ. time operation from 0)
Pulse shaping Blinker functions
Delay functions
On delay
S ⇒ R on with delaySOFF ⇒ R off
S ⇒ R onSOFF ⇒ R off with delay
Off delay
S ⇒ R on with delay (t1)SOFF ⇒ R off with delay (t2)
On and off delay
One shot leading edge
S ⇒ R on for tSOFF ⇒ R off(pulse clipping)
One shot trailing edge
SOFF ⇒ R on for tS on for t ⇒ R off
Shot timing modes
S ⇒ R on for t1SOFF ⇒ R on for t2SOFF off for t1 ⇒ R off
One shot leading and trailing edge
Star-delta timer
S ⇒ on for tOFF ⇒ on with delay for t -
SOFF ⇒ off
S ⇒ R after t on/off periodicallyaccording to tSOFF ⇒ R off
Blinker, interval startPulse shaping
SOFF ⇒ R on for tS no influence on R and t
: Pulse separation is smaller than the time tP Start with S1 = without start-up short-out tA: Pulse separation is larger than the time tP Start with S2 = with start-up short-out tA
tV = settable alarmdelay (tA = tV)
Pulse sequence monitoring
S1/S2 = Monitoring startP = Pulse sequencetP = Pulse separation
S ⇒ R on.SOFF ⇒ R off and starts t .S ⇒ R restart only after t .
Restart delay
S = TriggeringR = Output circuit⇒ = switches...
Special functions
t is stopped ⇒ R on/off
SRESET resets tt restarts immediately
SSTOP interrupts t(t-addition)
S ⇒ R on and starts t.S on for t ⇒ R off.
S ⇒ R on/off
Step-switching (staircase lighting timer), with time lapse
Special functions
Step-on/Step-off switch
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
53 KAT2008
Tim
e D
elay
Rel
ays
2
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.
Plug-in Time Delay Relays
Type
Function
t-St
op
t-Res
et
Ext.
Poti
t max.
E A F W N Q K L M B B1 B2 G H I P S LS X1 U V sec min hrs day Page
CT..-E 30 30 61CT..-A 30 30 61CT..-K 30 30 61CT..-W 30 30 61CT..-B 30 30 61CT30 1) 30 63CT32 1) 60* 63CT33 1) 60* 63CT36 1) 60* 63C81 30 67C82 60 67C83 60* 67C84 20 67C85 60* 67CS1 60* 68CS2 60* 68CS3 60* 68C63 60* 68C64 20 69C65 6 69C66 6 69C52 60 70C53 60 70C55 60 70C56 60 70
Type
Function
t-St
op
t-Res
et
Ext.
Poti
t max.
E A F W N Q K L M B B1 B2 G H I P S LS Y U V sec min hrs day Page
RS 121 100 74RS 121.P 100 74RS 121.R 100 74RS 122-M 2x30 75RS 122-MH 30 30 75RS 122-H 2x30 75RS 321 99,9 76RS 521 99,9 76RS 41 15 76CPX-519 999 77CTI-519 2x999 77CEA-226 990 77CPX-129 15 78CFG-126 2x15 78CTI-129 2x15 78CEA-126 15 79CWR-102 1,5 79CX 38 15 80CX 39 1) 0,1 15 80CNS-4 30 90CN 135 30 90
Type
Function
t-St
op
t-Res
et
Ext.
Poti
t max.
E A F W N Q K L M B B1 B2 G H I P S LS Y U V sec min hrs day Page
CRE1 30 82CRA1 30* 82AE2 1,5 82AE2M 12 82AA2 1,5 82AA2M 12 82CY1 60/0,1 82CRV1 30 83CRV2 60* 83CSV2 10* 83CRV3 2x60* 83CRT3 2x60* 83AM1 60 84AM2 60 84AM3 1) 60 84CIM1 60 84CM1 100 85CM1L 12 85CM2 12 85CM3 60 85CNR1 12 86CT1 12/60 86CT1L 60 30 86ECO31 20 87ECO32 12* 87CPF11 0,6 94CPF22 0,2 94
Plug-in Time Cubes andTime Modules pour Industrial Relays
Plug-in Time Delay Relays
DIN Time Delay Relays
Special devices from page 89
* TF-60The TF60 time setting methode permits short exami-nation of long delay time settings. Elapsing times of hours can be monitored in the sec. range.
Example for a delay time of 38h:1. Set range switch to 60sec2. Set 38sec on the potentiometer (e.g. check 38sec by chronometer)3. Set range switch to 60hThe delay time now amounts to 38h.
1) alternatively with instantaneous contact without auxiliary voltage (relay bistable) without auxiliary voltage (relay monostable)
t2 = t1 t2 = 0,5s
Serie
s
Time r
ange
Sock
et typ
e
Page
Conta
ct
54 KAT2008
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.
Plug-in Time Cubes forIndustrial Relays
The Comat CT System
Time Delay Relays
Monofunktions-Timer5 different timing functions with
delay time settings
CT2 0,2s-30min 10A 61
Monofunktions-Timer5 different timing functions with
delay time settings
CT3 0,2s-30min 10A 61
Economy Timer3 timing functions.
Mains controlled.LED indication
CT30.1 0,25s-30min 10A 63
CT30.3 0,25s-30min 10A 63
CT30.5 0,25s-30min 0,8A 63
CT30.7 0,25s-30min 5A 63
Universal Timer7 timing functions.
Mains kontrolled.Flashing LED shows time lapse.
CT32.1 0,15s-60min 10A 63
CT32.3 0,15s-60min 10A 63
CT32.5 0,15s-60min 0,8A 63
CT32.7 0,15s-60min 5A 63
Universal Timer12 functions, mains controlled.
Flashing LED shows elapsing time.Increased setting accuracy with 1:5
scale devision.
CT33.1 30ms-60h 10A 63
CT33.3 30ms-60h 10A 63
CT33.5 30ms-60h 0,8A 63
CT33.7 30ms-60h 5A 63
Universal Repeat Cycle TimerPulse or interval start.
Independent setting of t1/t2.Flashing LED shows time laps.
CT36.1 2 x 50ms-60h 10A 63
CT36.3 2 x 50ms-60h 10A 63
CT36.5 2 x 50ms-60h 0,8A 63
CT36.7 2 x 50ms-60h 5A 63
8-/11-pole plug-in time delay relay systemThe simplest time delay relay system world-wide, fitting all 8 or 11-pin relay sockets (octal /sub-magnalite).Original time cubes® are simply placed between socket and relay without rewiring.
In this way, even as a retrofit, all industrial relays can be provided with the required timing functions without additional space being required. The con-tact connections of the relay on the socket remain trough-connected.
The time delay relays and monitoring relays con-sist of the plug-in CT time function modul and 11-pole CT output relay and the system socket C12B. Both system components can be com-bined freely with one another. This allows the equipment to be selected optimally for specific use. Subsequent modifications, for example a change from mechanical contacts to solid-state outputs, are possible at any time by simple reconnec-tion. This provides the user a complete, universal system, the high flexibility of which is unique throughout the world.
Serie
s
Time r
ange
Conta
ct
Page
Sock
et typ
e
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
55 KAT2008
Tim
e D
elay
Rel
ays
2
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.
Plug-in Time Delay Relays
Time Delay Relays
Economy-Time Delay Relay 2 functions
C81 0,2s-30min 8A 67
Economy-Time Delay Relay 4 functions
C82 0,5s-60min 8A 67
Universal Multifunctional Time Delay Relay
C83 50ms-60h 8A 67
Time Delay Relay, no auxiliary voltage
C84 0,1s-20min 5A 67
Double Time Delay Relay and Repate Cycle Timer, 6 functions
C85 2x 50ms-60h 8A 67
Economy Time Delay Relay 4 functions
CS1 50ms-60min 8A 68
Universal Multifunctional Time Delay Relay, 7 functions
CS2 50ms-60h 8A 68
Universal Multifunctional Time Delay Relay
CS3 50ms-60h 6A 68
Universal Multifunctional Time Delay Relay
C63 50ms-60h 6A 68
Time Delay Relay without auxtliary voltage
C64 0,1s-20min 5A 69
Restart Delay Relay C65/66 1-6min 6A 69
Universal Multifunctional Time Delay Relay, 2 functions (digital)
C52 0,1s-60min 8A 70
Universal Multifunctional Time Delay Relay, 10 functions (digital)
C53 0,1s-60h 8A 70
Universal Multifunctional Time Delay Relay, 10 functions (digital)
C53.3 0,1s-60h 0,5A 70
Universal Multifunctional Time Delay Relay, 10 functions (digital)
C53.4 0,1s-60h 2A 70
Universal Multifunctional Time Delay Relay, 15 functions (digital)
C55 0,01s-60days 5A 70
Universal Multifunctional Time Delay Relay, 15 functions (digital)
C55.3 0,01s-60days 0,5A 70
Universal Multifunctional Time Delay Relay, 15 functions (digital)
C55.4 0,01s-60days 2A 70
Universal Multifunctional Time Delay Relay, 15 functions (digital)
C56 0,01s-60days 5A 70
Serie
s
Time r
ange
Sock
et typ
e
Page
Conta
ct
56 KAT2008
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.
Plug-in Time Delay Relays RS Serie
Multifunctional Time Delay Relay, 5 functions
RS121 10ms-100h 5A 74
Multifunctional Time Delay Relay, 5 functions
RS121.P 10ms-100h 5A 74
Multifunctional Time Delay Relay 5 functions with t-stop- and
t-reset-function
RS121.R 10ms-100h 5A 74
Universal Cycle Timer RS122- 0,1s-30h 5A 75
Digital Multifunctional Time Delay Relay, 5 functions
RS321 10ms-99,9h 5A 76
Digital Multifunctional Time Delay Relay with digital display
of elapsing time, 5 functions
RS521 10ms-99,9h 5A 76
Economy Multifunctional Time Delay Relay, 5 functions
RS41-M 0,1s-15min 6A 76
C Serie
Digital Multifunctional Time Delay Relay with digital display
of elapsing time, 5 functions
CPX519 0,01s-999min 6A 77
Digital Cycle Timer CTI519 2x 0,01s-999min
6A 77
Digital Multifunctional Time Delay Relay, 2 functions
CEA-226 0,1s-990min 6A 77
Multifunctional Time Delay Relay, 5 functions
CPX129 0,1s-15h 6A 78
Time Delay Relay with 3 double functions (t1/t2 individual)
CFG126 2 x 0,1s-5min 6A 78
Cycle Timer CTI129 2 x 0,1s-15h 6A 78
Multifunctional Time Delay Relay, 2 functions
CEA-126 0,1s-15min 6A 79
Single Shot Relay 3 functions
CWR-102 0,1-1,5s 6A 79
CX Serie
Multifunctional Time Delay Relay 3 functions
CX38 2x 0,1s-15h 6A 80
Star-delta TimerON.. with instantaneous contact
CX39 1-100ms0,1s-15h
6A 80
Time Delay Relays
Serie
s
Time r
ange
Conta
ct
Page
Overa
l widt
h
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
57 KAT2008
Tim
e D
elay
Rel
ays
2
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.
DIN Time Delay Relays
Time Delay Relays
Mono function Time Delay Relay
Economy Time Delay RelayON-Delay
CRE1 0,5s-30min 13 6A 82
Economy Time Delay Relay OFF-Delay
CRA1 0,3s-30min 13 6A 82
Mono functionEconomy Time Delay Relay
AE2 0,8s-12min 17,5 10A 82
Mono functionEconomy Time Delay Relay
AA2 0,8s-12min 17,5 10A 82
Star-Delta Time Delay Relay CY1 0,5-60s 17,5 6A 82
Extra slim 13mm
Multifunctional Time Delay Relay 3 functions
CRV1 0,5s-30min 13 6A 83
Universal Time Delay Relay 3 functions
CRV2 50ms-60h 13 6A 83
Universal Time Delay Relay 7 functions
CSV2 8ms-10h 13 1,5A 83
Double Time Delay Relay CRV3 50ms-60h 13 6A 83
Universal Repeat Cycle Timer CRT3 50ms-60h 13 6A 83
DIN A (Installation distribution panel)
Economy Time Delay Relay 4 functions
AM1 0,5s-60min 17,5 10A 84
Universal Time Delay Relay 4 functions
AM2 0,5s-60min 17,5 10A 84
Universal Time Delay Relay with instantaneous contact, 4 functions
AM3 0,5s-60min 35 10A 84
Universal Function Relay with9 functions including
Staircase Lighting Timer
CIM1 0,6s-60h 17,5 16A 84
DIN C (Industry)
Universal Time Delay Relay 4 functions
CM1 50ms-12h 17,5 6A 85
Universal Time Delay Relay, 4 functionswith external potentiometer and
t Stop/ t Reset input
CM2 0,3s-12h 35 6A 85
Universal Time Delay Relay, 7 functionsService ON/OFF
CM3 50ms-60h 17,5 6A 85
Time Delay Relay, no auxiliary voltage CNR1 0,1s-12min 17,5 5A 86
Universal Repeat Cycle Timer CT1 0,1s-30h 17,5 6A 86
22,5mm mounting series
Economy Time Delay Relay 3 functions
ECO31 0,5s-20min 22,5 6A 87
Multifunctional Time Delay Relay 6 functions
ECO32 0,1s-12h 22,5 6A 87
Serie
s
Time r
ange
Conta
ct
Page
Sock
et typ
e
58 KAT2008
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.
Specially Time Delay Relays
Amplifier Relays
Pulse Shapers
Preset Counters
Time Delay Relays
Cascade Relay CNS-4 0,1s-30min DIN 35 4x 6A 90
Multifunctional Time Delay Relay 2 functions, external potentiometer
CN 135 0,1s-30min DIN 35 8A 90
Universal Timer Module for PCB mounting
5 functions
CU 23 0,01s-300min 32 x 32mm
PNP 120mANPN 150mA
90
Amplifi er Relay, Switching Amplifi er SFR1 Amplifier for 3 wire and Namur Sen-sors. Potential free contacts.
5A 92
Amplifi er Relay, Switching Amplifi er SFR2 Amplifier for 3 wire and Namur Sen-sors. Potential free contacts.
6A 92
Amplifier Blinker SBV11 For direction indi-cation blinkers in vehiles. High life expectancy.
10A DC 93
Switching Amplifi er SSV11 For high switching numbers.
10A DC 93
Single Channel Pulse Shaper4 functions
CPF11 5-600ms DIN 17,5 PNP DC0,8A
94
Double Channel Pulse Shaper4 functions
CPF22 50/200ms DIN 17,5 2 x DC150mA
94
Preset Counters 3 functions
CCX350 Switching after the preset number of pulses are rea-ched, max. 999
6A 95
Preset Counters with display 3 functions
CCX550 Switching after the preset number of pulses are rea-ched, max. 999
6A 95
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
59 KAT2008
Tim
e D
elay
Rel
ays
2
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.
Time Delay Relays
Plug-in Time Cubes andTime Delay Modules
Time Cubes®: CT2 and CT3
CT-System: CT30, CT32, CT33, CT36
60 KAT2008
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.
Comat products comply with different international standards and are certified accordingly.
A detailed list can be found on our web page:
www.comat.chLloyd’s; IEC 61810; EN 60974
Notes
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
61 KAT2008
Tim
e D
elay
Rel
ays
2
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.
Function Page: 52; TF-60 setting: Page 53; Socket and Accessories: Page 97
S+
A1A2
S
+
A1A2 B1
S+
A1A2 B1
<108 11
9
4 1
35
6 7
14 3 5 86 7 119
SCT3
RELAY
+
B1
210A1A2
Socket
275 8
6
S
4 1
3
RELAY14 3 5 8 6
CT2
+
B1
27A1A2
Socket
E
W
B
A
K W
CT.. -W30 / ...
CT .. - E 30 / ...
CT .. - A30 / ...
CT .. - K30 / ...
CT .. - B30 / ...
0,2s-30min0,2-3s/min • 2-30s/min
EC-11 10A400V
10A300VListed10A
400V
029 8 7 5 3 4
34 32 24 22 14 12
10
A2
11 6 1 2
31 21 11 A1
38
3230
SLH
SLMU
SLMU
SLH
SLH
UC
180
-265
V
UC
90-1
50V
UC
90-2
65V
UC
20-6
5V
DC
9,5
-18
V
6 5 4 3
24 22 12 14
7 8 1 2
A2 21 11 A1
EC-8 10A400V
10A300VListed10A
400V
02
62
38
0,2s-30min0,2-3s/min • 2-30s/min
EC-11EC-8
UCAC/DC
DC10%
CT2/CT38 11
ON OFF
t RS
K
t t t RS
B
tW RS
t RS
A
t RS
E
MAX 10A 250VA
25 422
Clip
CT2/3
For Relay*C21...C39
For RelayC2...C3
S3-CT
58 (51*)
HF-33
Plug-in Time Cubes
8-/11-pole Plug-in Time Delay Relay SystemThe simplest time delay relay sys-tem world-wide, fitting all 8 or11-pin relay sockets (octal /sub-magnalite).Original time cubes® are simply placed between socket and relaywithout rewiring.In this way, even as a retrofit, all industrial relays can be providedwith the required timing functions without additional space beingrequired. The contact connections of the relay on the socket remainthrough-connected.
Function
Order no.
CT2 (8-pin) CT3 (11-pin)
Industrial relay
Time cube®
All new types ..30 (0,2s-30min) are fully compatible with allprevious types ..20, ..21 and ..25.
Triggering
Industrial relay Socket
2 = 8 -pole3 =11-pole
Time cubes CT2-E30/HSocket EC-8 or CS-8
Relay C2-...
Time cubes CT3-E30/HSockel EC-11 oder C11A
Relay C3-...
Ordering example
Time Cubes
Blinker, pulse start
Pulse shaping
One shot leading edge
Off delay
On delay
S ⇒ R on/off periodicallyaccording to tSOFF ⇒ R off
S (pulse or continuous contact)⇒ R on for tS no influence on R and t
S ⇒ R on with delaySOFF ⇒ R off
S ⇒ R onSOFF ⇒ R off with delay
S ⇒ R on for tSOFF ⇒ R off(pulse clipping)
S = TriggeringR = Output circuit⇒ = switches...
and others:www.comat.ch
SIMPLY PLUGED
BETWEEN
62 KAT2008
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.
Function Page: 52; TF-60 setting: Page 53; Socket and Accessories: Page 97
S+
A1A2
S
+
A1A2 B1
S+
A1A2 B1
CT30 / ....V CT32 / ....V CT33 / ....V CT36 / ....V
PI
E BW 0,25s-30min0,25-3s...2,5-30min
0,15s-60min0,15-1,5s...6-60min
30ms -60h30-150ms...12-60hBHW
L KFA
E
N G B1
A
E
K
BW
N B1
CT30
CT32
CT33
CT36
t2=t1 t2=0,5s
( )
S
a)
L(+)
N
A1B1
A2
2x50ms -60h2x 50-600ms...5-60h
UC 24-48V UC 24-48V UC 24-48VUC 24-48V
UC110-240V UC110-240VUC115V, UC230VUC115V, UC230V
CT-System11
MODULE
RELAYS
EF O G H
Multifunction Time Delay Relays, Modular
Order no. for individual module (without output relay):
Economy timer3 functions, voltage con-trolled, output LED.Seismic approved.
Universal timer7 functions, voltage con-trolled, time lapse display,blinking.Seismic approved.
Universal timer12 functions, voltage con-trolled, time lapse display,blinking, high setting accu-racy by dial graduation 1:5.
Universalrepeat cycle timerPulse or pause start.t1/t2 separately settable.Time lapse display t1/t2.
Timer module Function/triggering Time range
The Comat CT System is modular.The time delay relays and monitoring relays consist of the plug-in CT electronicmodule and an 11-pole CT output relay. Both system components can be com-bined freely with one another. This allows the equipment to be selected optimallyfor specific use.Subsequent modifications, for example a change from mechanical contacts tosolid-state outputs, are possible at any time by simple reconnection.This provides the user a complete, universal system, the high flexibility of whichis unique throughout the world.
The system socket C12B0 servesas a basis for the vibration-free recep-tion of the electronic module. It has a4-pole module slot in which the CT-module –also without output relay–locks in such a way that it is vibra-tion-free. Contact is via twin knife con-tacts which ensure optimal contact re-liability.
With the A2-connector C-A2plug-in flush in the socket, the neutralconductor (N / –) can be connectedas a 10A bus from socket to socket.This considerably reduces wiringwork.
Robust terminals for cross-sectionsup to 4mm2 and generous labellingfacilities are other advantages of thispractical comat system socket. As var-iants to the standard socket C12B0,two identical sockets, but with printeddevice diagram, are available(C12B1/2). By clearly identifying theconnections, these sockets ensure ra-pid, error-free and therefore eco-nomical wiring. When a service is re-quired, they faciliate fault location.
The CT module demonstrates co-mat's practical experience in the areaof industrial electronics. All controland display elements are arranged onthe front and are labelled in a self-explanatory manner for internationaluse. The values set are also clearlylegible when the module has been in-stalled.
Printed diagrams explain the func-tions, and the connection scheme di-rectly indicates the appropriate termi-nals in the system socket.
A transparent front cover providesprotection from unauthorized mis-adjustment and additionally locks themodule onto the output relay.
Triggering is performed with theoperating voltage (L1or +). Hence,no potential-free contacts are re-quired. Triggering complies with themachine standards. A parallel con-nection of other users to B1 is admis-sible.
The 2 voltage ranges UC110-240Vand UC24-48V have been chosen bycomat to ensure a high level of reliabi-lity in triggering. They permit use withan AC or DC supply and optimal ad-aptation to the operating conditions ofmodern controls.
In case of an even broader voltagerange, e.g. 24-240V it is often pos-sible to achieve only currents of a few100µA in the trigger circuit B1 with si-multaneous low threshold voltages toless than 20V. This may lead to unin-tentional triggering due to capac-itive/inductive pickups, or faultyswitching may occur owing to suffi-ciently loaded control contacts.During operation, 50V are readilymeasured on open-ended lines.
The consumption of the CT mod-ules comes to less than 1W.
The output relays have the com-plete device diagram, the perform-ance data and the complete order no.on the front, supported by a colourcode, which indicates an AC coil withred and a DC coil with blue. The .1and .2 relays have a safety manualoperation facility as a standard fea-ture, which switches the contacts onlyafter a lock has been released (two-hand principle).
The standard contacts .1 and .3have proved their worth millions of ti-mes in heavy current applications.The contact material AgNi permits alarge switching range and thanks togenerous dimensioning achieves ahigh number of cycles. With its highbreaking capacity of up to 10A/400V,this contact is a reliable allround con-tact for use both in mains circuits andin the lower voltage range from12V/10mA.
The twin contacts .2 and .4 switchevery circuit with two independentreeds. Compared with single contacts,they provide up to 100 times greatersafety with regard to the level of pos-sible faulty switchings. In spite of theirhigh breaking capacity of up to6A/250V, these contacts are partic-ularly suitable for low switching cur-rents and switching voltages down to1mA/6V.
The solid-state relays are used in-stead of mechanical contacts. In thestandard version .5, the relay has apotential-free output which switchesan AC or DC load in the same way asa mechanical contact. However, itfunctions without bounce or wear,withstands overloads, has short-circuit protection and has a practicallyunlimited life even with full outputload.
Preferred applications are highswitching frequency, for example asrepeat cycle timers, flashing bars withbulb load or extreme inductive loads,for example large solenoid valves,couplings, motors, etc.
An additional protective wiring ofthe output or of the load is not neces-sary in these comat relays for any ap-plication.
They are completely insensitive inan aggressive atmosphere, forexample in the chemical industry, inwaste water treatment plants, etc.
Note on useAccording to the standards «Safety of machines»e.g. EN 60204-1, EN 292-2, triggering with A2-potential (N /–) is only admissible in exceptionalcirumstances.For that reason the comat CT modules are trigge-red by A1-potential (L /+).This makes them unrestrictedly suitable also foruse in machines and systems which must con-form with machine or CE guidelines or directives.
a) A parallel load at B1is admissible on allCT30 modules.
Triggering
TF60 setting(page)
and otheres:www.comat.ch
Function (page)
Triggering
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
63 KAT2008
Tim
e D
elay
Rel
ays
2
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.
Function Page: 52; TF-60 setting: Page 53; Socket and Accessories: Page 97
CT36.1/....V CT36.3/....V CT36.5/....V CT36.7/....V
CT30.1/....V CT30.3/....V CT30.5/....V CT30.7/....V
7 5
11 6A1A2
10 2+
3
121B1
R
9 8 4
+RL
+ O
MODULE
K
5)
CT32.1/....V CT32.3/....V CT32.5/....V CT32.7/....V
CT33.1/....V CT33.3/....V CT33.5/....V CT33.7/....V
.1 .3 .5
C31/ ...V3) C35 / ....V C37 / ....VC33 / ....VC31L / ...V4)
.7
DC24,48,110,220V
AC24,48,115,230V
DC24,48,110,220V
AC24,48,115,230V
UC24-48V
AC110-240V
UC24-48V
UC110-240V
DC24,48,110,220V
AC24,48,115,230V
DC24,48,110V
AC24,48,115,230V
UC24-48V
AC110-240V
UC24-48V
AC110-240V
UC24-48V
AC115,230V
UC24-48V
UC110-240V
MODULE
17 18
11 6A1A2
10 2+
3 4
121B1
R
79 8 5
+RL
K
AC50/60Hz
UCAC/DC
DC10%
1)
18
15
79 8 538 36 16
11 635
R
A1A210 2
+
3 4
12 125
2628
B1
MODULE
RELAY: C31L /... RELAY: C33/... RELAY: C35/... RELAY: C37/...
UC24-48V
UC115,230V
UC24-48V
UC110-240V
10A 250VA 2) 0,8A 10-265VU10A 250VA 1) 5A 10-30VD
RELAY
MOD
UL
CT-System11
MAX
A
MODULE
151
1879 8 5
14 12 16
11 611
R2
A1A210 2
+
3 4
12Y1
Y3Y2
B1
R1
2628
25
B
2)
2x
DC24,48,110,220V
AC24,48,115,230V
DC24,48,110,220V
AC24,48,115,230V
DC24,48,110,220V
AC24,48,115,230V
DC24,48,110V
AC24,48,115,230V
DC24,48,110V
AC24,48,115,230V
DC24,48,110V
AC24,48,115,230V
UC24-48V
AC115,230V
UC24-48V
UC115,230V
System socket C12B0Figure: with plug-in neutralconductor connector C-A2
Solid-state outputfor AC or DC load
Order no. for individual ouput relay (without module):
2x1changeover cont.(with instantan.contact)
Solid-state outputfor DC load
1) Same relay, but withtwin contacts 6A 250VAorder no. CT...2 / ...V
2) Same relay, but withtwin contacts 5A 250VAorder no. CT...4 / ...V
3) To module CT30(Relay without output LED)
4) To module CT32÷36(L= Relay with output LED)
5) For relay C3...(instead of C31/32, or CT...1/.2):Retaining clip S3-CFront cover FS-R
Time Delay Relay assembled (module + output relay)
Order no. for module + ouput relay (delivery unit):
Order no.
A Jumper 5-7 : R2 = R1B Jumper 6-12 : R2 = S
Order no. for module + ouput relay (delivery unit):
Order no.
Order no.
Order no.
Contact outputs Solid-state outputs
3 changeover cont.
Ordering example
Timer CT32.1/AC230VSocket C12B0
and otheres:www.comat.ch
The Time Relays CT30.., CT32.., CT33.. andCT36.. consist of modules (incl. cover) andoutput relays. The socket has to be orderedseperatly.
The modules can also be combined with otherComat relays. In this case the relays and themodules have to be ordered seperatly.
Please refer to chapter industrial relays fordatas..
Please refer to chapter IndustrialRelays for relay datas.
64 KAT2008
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.
Comat products comply with different international standards and are certified accordingly.
A detailed list can be found on our web page:
www.comat.chLloyd’s; IEC 61810; EN 60974
Notes
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
65 KAT2008
Tim
e D
elay
Rel
ays
2
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.
Time Delay Relays
Plug-in Time Delay Relays
• Multifunction Time Delay Relays• Restart Delay Relays
66 KAT2008
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.
Comat products comply with different international standards and are certified accordingly.
A detailed list can be found on our web page:
www.comat.chLloyd’s; IEC 61810; EN 60974
Notes
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
67 KAT2008
Tim
e D
elay
Rel
ays
2
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.
Function Page: 52; TF-60 setting: Page 53; Socket and Accessories: Page 97
S+
A1A2
S
+
A1A2 B1
S+
A1A2 B1
C82 / ....V
A
C83C81
C81 / ....V
E
C82 C84 C85
C83 / ....V C84 / ....V
0,5s-60min0,5-6s...5-60min
0,1s-20min0,1-1,2s...1,7-20min
50ms-60h
50-600ms...5-60h
C85 / ....V
2x 50ms-60h
2 x 50-600ms...5-60h
NAB2 E
K HF O
I
G
18 16
5
RA1A2
8 7
3 124
15
+6
18 16
5
RA1A2
8 7
3 124
15
+6B1
18 16
5
RA1A2
8 7
3 124
15
+6B1
BHW
L KF OA
E
N G B1
18
5
RA1A2
8 7
3 124
15
+6B1
16 18
5A1A2
8 7
34
17
+625
262 1
R
W
P
F Ot2=t1 t2=0,5s
HG
67
21
1324
11
8 756B1A2 A1
24 1222 14
2
4
6
8
1
3
5
7CS-18
22,5
75
AC110-240V
UC 24-48V
AC230V
AC115V
UC24-240V
UC24V
UC110-240V
UC24-48V
68
7
36
8
224
C81C82
C83,84,85
E
C80
MAX
0,2s-30min0,2-3s...2-30min
8A 250VA 8A 250VA 8A 250VA 5A 250VA 8A 250VA
AC110-240V
UC 24-48V
AC 50/60Hz
UC AC/DC
AC230V
AC115V
UC24-240V
UC24V
Universal Multifunc-tional Time Delay Relay• 12 functions + ON(Test),
voltage controlled.• Time lapse display
(double blinking=t2)• Input-LED (24-240V)• Output-LED• Seismc approved.
EconomyTime Delay Relayon delay or blinking,voltage controlled,output-LED.
EconomyTime Delay Relayon delay,off delay,one shot leading edge,pulse shaping K,voltage controlled,output-LED.
Time Delay Relay,no auxiliary voltage• Off delay• One shot trailing
edge• Triggering display• Minimum triggering
time 150ms only• Seismc approved.
Double Time Delay Relayand Repeat Cycle Timer• 6 functions + test• t1/ t2 separately settable• Time lapse display
(double blinking=t2)• Input-LED (24-240V)• Ouput-LED• Seismc approved.
22,5mm Plug-inTime Delay Relay Systemfor all delay, shot timing andblinking functions.Double functions, repeat cycletiming and functions withoutauxiliary voltage.
System socket CS-18Figure: with inserted retaining clips(standard delivery with relay)
Triggering
Multifunctional Time Delay Relays
Time range TF60 setting (page)
no auxiliary voltage
Ordering no.
Function (page)
Triggering
Ordering example
Timer C83/UC24-240VSocket CS18
and otheres:www.comat.ch
THE PRACTICAL ONES
68 KAT2008
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.
Function Page: 52; TF-60 setting: Page 53; Socket and Accessories: Page 97
50ms-60min
50-600ms...5-60min50ms-60h
50-600ms...5-60h
W BE B2
K
W B
A
E B2
N
CS1 CS2
CS1 / ....V CS2 / ....V
7 5/6Z2 Z1
1 2 3
1M
max. 50m
EXT POT
CS1/2
3 4B1
1B1
EXT POT
79 8 518 16 Z2 Z1
11 615A2
10Z1 A1
2
R
+
Z2
Z1
379 8 5 418 16 Z1
11 6 115
RA1A2
10 2
EXT POT
+
CS3 / ....V
K
W B
A
E B2
N
50ms-60h
50-600ms...5-60h
S+
A1A2
S
+
A1A2 B1
UC110-240V
UC24-60V
UC12-15V
UC110-240V
UC24-60V
K
W B
A
E B2
N
50ms-60h
50-600ms...5-60h
C63 / ....V
28
25
269 8
18 163
1115A2
10 1
RA12+
5
6B1
B17 4
+
428
25
2679 8 5
18 163B1
11 615A2
10 1B1
RA12
+
E
1
2
3
45 6
7
8
910
MAX 8A 250VA 8A 250VA 6A 250VA 6A 250VA
CS, C6011
UC110-240V
UC24-60V
UC12-15V
UC110-240V
UC24-60V
UC12-15V
UC AC/DC
Replaces fully compatibleCSE3, CSA3
Economy Time Delayand Blinker RelayWith additional connectionfor remote potentiometerSP-01/1M (up to 50m).
Universal Multifunc-tional Time Delay Relaylike CS1, but with 7 func-tions and delay times upto 60 hours.
Universal Multifunc-tional Time Delay Relaylike CS2, but with 2ndcontact instead of Z1-Z2(terminal 6-5-7).
Replaces fully compatibleCSE2, CSB2
Replaces fully compatibleCSA2,CSK2,CSN2
System socket C11AFigure: with plug-in neutral conductorconnector C-A2 (standard delivery).
11-pole Plug-inTime Delay Relay Systemfor all delay, short timing and blinkingfunctions from 50ms up to 60 hours.CS1, CS2 with connection for remotepotentiometer. Front panel mountingwith FZ-50.
Built-inpotentiometerSP-01/1M(page)
Time range TF60 setting (page)
Triggering
Replaces fully compatibleCX35, CX36
Universal Multifunc-tional Time Delay Relaylike CS3, but with 2ndcontact on terminal 1-4-3.
CS3 (2nd contact: 6-5-7) C63 (2nd contact: 1-4-3)
2nd contact: 6-5-7 2nd contact: 1-4-3
Multifunctional Time Delay Relays
Ordering no.
Function (page)
Triggering
and otheres:www.comat.ch
Ordering example
Timer CS2/UC110-240VSocket C11A
THE MULTIS
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
69 KAT2008
Tim
e D
elay
Rel
ays
2
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.
Function Page: 52; TF-60 setting: Page 53; Socket and Accessories: Page 97
C65 (50Hz) C66 (60Hz)
0,1s-20min0,1-1,2s...1,7-20min
NA
C64
C64 / ....V
28
25
269 8
18 163
1115A2
10 1
RA12
+
7 5
6
428
25
269 8
18 163
1115A2
10 1
RA12
7 5
6
4
1-6min1-1,5 ...4-6min
50Hz 60Hz
C65 / ....V C66 / ....V
S+
A1A2
X1
0-
N
M3A
CONTACTOR
C65/66
t
L
S
R
t R
S
R
St
C6411
MAX 6A 250VA5A 250VA
C65, C6611
X1
ACUC110-240V
UC24-60V AC230V
AC115V
AC230V
AC115V
Time Delay Relay with-out auxiliary voltageTrue off delay or one shottrailing edge after cut offpower supply.Minimum triggering time150ms only.Seismc approved.
Do not connect 5-6-7!
Replaces RS124, CSR2
without auxiliary voltage
Restart Delay RelayThe C65 (50Hz) and C66(60Hz) are special timers withno auxiliary voltage to guaran-tee a minimum OFF time afterremoval of supply. After the in-terruption of supply, the devicewill not reclose before the set ti-me (1-6mins.) has elapsed,
even if there has been a newcommand to switch ON.Typical application:After a mains failure it is notpossible to restart (close con-tacts) before the machine is atrest. Example: Motor (see dia-gram on the left).
Restart Delay Relay
System socket C11AFigure: with plug-in neutral conductorconnector C-A2 (standard delivery).
Time rangePartial ranges
Triggering
Function (page)
Triggering
Ordering no.
and otheres:www.comat.ch
Ordering example
Timer C64/UC110-240VSocket C11A
Ordering example
Timer C65/AC230VSocket C11A
NO UNDEFINED PROCESS
CONDITIONS AFTER
MAINS INTERRUPTION
70 KAT2008
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.
Function Page: 52; TF-60 setting: Page 53; Socket and Accessories: Page 97
UC110-240V
UC24-60V UC24-60V
UC110-240V
UC24-60V
UC110-240V
0,1s-60min
C52 C53 (C53.3, C53.4) C55 (C55.3, C55.4)
C52 / ....V
0,1s-60h0,1s-60min...0,1min-60h
0,01s-60days0,01-60s...0,1h-60days
C53 / ....V
A
E
C55 / ....V
WE H B I
A K OFN
18 16
615
RA1A2
10 2
+
3 47 589
B1111
18 16
615
RA1A2
10 2
+
3 47 589
B1111
S
+
A1A2 B1
S+
A1A2 B1
C56 / ....V
C56
0,01s-60days0,01-60s...0,1h-60days
28
25
2679 8 5
18 163
Y1
11 615A2
10 1B1
RA12
+
4Y2
RESE
T
STO
P
28
25
2679 8 5
183
11 617A2
10 1Y2
RA12
+
4B1
RESE
T
STAR
T
STO
P
COM Y1
+10
V
E
C5011
8A 250VAMAX 8A 250VA 5A 250VA 5A 250VA
A
E
K N M G F Q
W H B I P
U VU V
A
E
K N M G F Q
W H B I P
S2
7 5COM
6A210
Y2 A12
S1
B1
(P)
4Y1
+
S2
7 5
6A210
B1 A12
S1
Y2Y1
+(P)
DC 10%
AC 50/60Hz
UC AC/DC
AC230V
AC110-120V
UC24V
Universal Multifunc-tional Time Delay Relay• 2 functions• 0.1s-60min (quartz)• 1 change-over contact
Universal Multifunc-tional Time Delay Relay• 10 functions• 0.1s-60h (quartz)• 1 change-over contact• Alternatively solid-state
output .3 or .4
Universal MultifunctionalTime Delay Relay• 15 functions incl. Puls se-
quence monitoring (U/V)• 0.01s-60 days (quartz)• Setting step up to 60s :1ms• t-STOP and t-RESET input• 2 changeover contacts• Alternatively solid-state
output .3 or .4• Seismic approved)
11-pole Plug-inTime Delay Relay Systemfor all timing modes from 10ms upto 60 days. Extremly accurate due toquartz time base.Digital functions and residual timedisplay.Front panel mounting with FZ-50.Test function .
Time rangePartial ranges
Triggering
Universal MultifunctionalTime Delay Relaylike type C55, but withpotential free triggering ofSTART, STOP and RESET(insulation from 2-10: 2kV).
System socket C11AFigure: with plug-in neutral conductorconnector C-A2 (standard delivery).
Multifunctional Time Delay Relays
Ordering no.
Function (page)
Triggering
Ordering example
Timer C53/UC110-240VSocket C11A
and otheres:www.comat.ch
THE MASTERS
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
71 KAT2008
Tim
e D
elay
Rel
ays
2
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.
Function Page: 52; TF-60 setting: Page 53; Socket and Accessories: Page 97
C53.3 / ...V
C55.3 / ...V
UC110-240V
UC24-60V
+
A12
A210
R183
KPNP
RL17
183
1
+
A12
R K
RLA210
DC24V
C53.4 / ...V
C55.4 / ...V
C53.3C55.3
C53.4C55.4
DISPLAY
min
sec
STPRST
,
TIME
t RESET
t STOP
FUNCTION
S INPUT
R OUTPUT
t
tt1t1tA
t
t2tP
t
t2
tV
E W KA N MBF QH G I PU V
Solid-state output for C53, C55(instead of contact)
For AC or DC load0,5A10-265VU
For DC load2A 24VD
Option*
Time setting
FunctionFunction switch
Time inquiryOutput ON/OFF
72 KAT2008
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.
Comat products comply with different international standards and are certified accordingly.
A detailed list can be found on our web page:
www.comat.chLloyd’s; IEC 61810; EN 60974
Notes
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
73 KAT2008
Tim
e D
elay
Rel
ays
2
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.
Time Delay Relays
Plug-in Time Delay Relays
• RS Series• C Series• CX Series
74 KAT2008
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.
Function Page: 52; TF-60 setting: Page 53; Socket and Accessories: Page 97
RS 121 RS 121.P RS 121.R
RS 121/ ....
10ms-100hms; s; min; h
RS 121.P/ .... RS 121.R/ ....
50/60Hz
AC/DC
DC 10%
E
RS12111
5A 250VAMAX 5A 250VA
A K N
WE
A K N
WE
A K N
WE
5A 250VA
10ms-100hms; s; min; h
10ms-100hms; s; min; h
STOP RST
AC
UC
10
9 8 7 5 3 422243234
1131
621
1
18 16
15A2 A1
2
R
+
EXT POT1M
10
9 8 7 5 3 422243234
1131
621
1
18 16
15A2 A1
2
t R
+10
9 8 7 5 3 422243234
1131
621
1
18 16
15
28 26
25A2 A1
2
R
+
PNP
NPN
3 4
+
1S
A1A2
3 4
+
1
+PNP/NPNA1A2
S
4
+
1 A1A23
t -STOP
t -RESET
AC220-240V ATX
AC110-120V ANP
UC24-48V UFK
UC12V UCB
DC110-240V DNX
AC220-240V ATX
AC110-120V ANP
UC24-48V UFK
AC220-240V ATX
AC110-120V ANP
UC24-48V UFK
204
4
16
C-A2
FOR PLUG-INMODULES
(M4)
9FS-23
92
38
x72
cm
7 5/6Z2 Z1
1 2 3
1M
max. 50m
CS1/2
1
2
3
45 6
7
8
910
EXT POT
Ordering no.
Multifunctional Time Delay Relay• 5 functions• 2 change-over contacts• potential-free triggering or
sensor PNP/NPN
Multifunctional Time Delay Relay• 5 functions• 2 change-over contacts• potential-free triggering or
sensor PNP/NPN• with connection for remote
potentiometer
Multifunctional Time delay Relay• 5 functions• with t-stop and t-Reset function• 1 change-over contact• potential-free triggering or
sensor PNP/NPN
Built-inpotentiometerSP-01/1M(page)
Timer RS 121/ATXSocket C11A
Ordering example
Function (page)
TriggeringTriggering
Plug-in Time Delay Relays
and otheres:www.comat.ch
Time Delay RelaysField proven since many years.The plug-in timer series from comatfor highest quality requirements andunattained versatile operation.
Time rangePartial range
DiagramConnectionwith socket C11A
System socket C11AFigure: with plug-in neutral conductorconnector C-A2 (standard delivery).
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
75 KAT2008
Tim
e D
elay
Rel
ays
2
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.
Function Page: 52; TF-60 setting: Page 53; Socket and Accessories: Page 97
S
3
+
1 A1A2
RS 122-M RS 122-MH RS 122-H
RS 122-M/ ....
50/60Hz
AC/DC
DC 10%
E
RS12211
5A 250VAMAX 5A 250VA
I
P
5A 250VA
t I: 0,1s-30mint P: 0,1s-30min
AC
UC
t I: 0,1s-30mint P: 0,1min-30h
t I: 0,1min-30ht P: 0,1min-30h
I
P
I
P
RS 122-MH/ .... RS 122-H/ ....
S
3
+
1 A1A2
10
9 8 7 5 3 422243234
1131
621
1
18 16
15
28 26
25A2 A1
2
R
+10
9 8 7 5 3 422243234
1131
621
1
18 16
15
28 26
25A2 A1
2
R
+10
9 8 7 5 3 422243234
1131
621
1
18 16
15
28 26
25A2 A1
2
R
+
AC220-240V ATX
AC110-120V ANP
UC24-48V UFK
UC12V UCB
DC110-240V DNX
AC220-240V ATX
AC110-120V ANP
UC24-48V UFK
UC12V UCB
DC110-240V DNX
AC220-240V ATX
AC110-120V ANP
UC24-48V UFK
UC12V UCB
DC110-240V DNX
204
4
16
C-A2
FOR PLUG-INMODULES
(M4)
9FS-23
92
38
x72
cm
Ordering no.
Ordering example
Timer RS 122-M/ATXSocket C11A
Function (page)
and otheres:www.comat.ch
System socket C11AFigure: with plug-in neutral conductorconnector C-A2 (standard delivery).
DiagramConnectionwith socket C11A
Universal Cycle Timer• pulse or interval start• Time range 0,1s-30min• 2 change-over contacts
Universal Cycle Timer• pulse or interval start• Time range: pulse 0,1s-30min
interval 0,1min-30h• 2 change-over contacts
Universal Cycle Timer• pulse or interval start• Time range 0,1min-30h• 2 change-over contacts
Cycle TimerField proven since many years.The plug-in timer series from comatfor highest quality requirements andunattained versatile operation.
Triggering Triggering
Time range
Repeat Cycle Timer
76 KAT2008
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.
Function Page: 52; TF-60 setting: Page 53; Socket and Accessories: Page 97
RS 321 RS 521 RS 41-M
RS 321/ ....
0,1s-15mins; min
RS 521/ .... RS 41-M/ ....
50/60Hz
AC/DC
DC 10%
E
RS 321, 521RS 41
11
5A 250VAMAX 6A 250VA5A 250VA
0,01s-99,9hs; min; h
AC
UC
10
9 8 7 5 3 422243234
1131
621
1
18 16
15
28 26
25A2 A1
2
R
+
PNP
NPN
3 4
+
1S
A1A2
S
4
+
1 A1A23
0,01s-99,9hs; min; h
NPN
3 4
+
1S
A1A2
S
4
+
1 A1A235
6
3 4
+
1S
A1A25
6
3 4
+
1S
A1A2 65
E W B
A K
E W
A K N
1-15s0.1-1.5s
0.35
5 Hz...
1-15m 0.1-1.5m 0.1s-15m
2
8 106
4
1214
RS 41-M
10
9 8 7 5 3 422243234
1131
621
1
28 26
25A2 A1
2
R
+
AC220-240V ATX
AC110-120V ANP
UC24-48V UFK
UC12V UCB
DC110-240V DNX
AC110-240V ANX
UC24-48V UFK
DC110-240V DNX
AC220-240V ATX
AC110-120V ANP
UC24-48V UFK
10
9 8 7 5 3 422243234
1131
621
1
18 16
15
28 26
25A2 A1
2
R
+
t-STOP
WE
A K N
985
FS-40
5
204
4
16
C-A2
FOR PLUG-INMODULES
(M4)
992
FS-23
38
x72
cm
36
x40c
m
Ordering no.
Ordering example
Timer RS 321/ATXSocket C11A
Function (page)
System socket C11AFigure: with plug-in neutral conductorconnector C-A2 (standard delivery).
Time rangePartial range
DiagramConnectionwith socket C11A
Triggering Triggering
Digital MultifunctionalTime Delay Relay• 5 functions• 2 change-over contacts• potential-free triggering
Digital MultifunctionalTime Delay Relay• digital time elapse display• time stop function• 2 change-over contacts• potential-free triggering
Economy MultifunctionalTime Delay Relay• 5 functions• 1 change-over contact• potential-free triggering• with front cover
Time Delay Relay11-pole plug-in time relay for highest requirementin regard to quality and performance.Application-oriented, universal employment,operator friendly.
and otheres:www.comat.ch
Plug-in Time Delay Relay
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
77 KAT2008
Tim
e D
elay
Rel
ays
2
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.
Function Page: 52; TF-60 setting: Page 53; Socket and Accessories: Page 97
CPX-519 CTI-519
CPX-519/ .... CTI-519/ ....
50/60Hz
AC/DC
DC 10%
E
CPX, CTICEA
11
6A 250VAMAX
2x 0,01s-999mins; min
0,01s-999mins; min
AC
UC
6A 250VA
AC110-240V ANX
UC24-48V UFK
UC12V UCB
DC110-240V DNX
AC110-240V ANX
UC24-48V UFK
UC12V UCB
DC110-240V DNX
10
9 8 7 522243234
1131
621A2 A1
2+
314
412
111
R18 16
15
28 26
25
10
9 8 7 522243234
1131
621A2 A1
2+
314
412
111
R18 16
15
28 26
25
5
S+
A1A27
6
E
A K N
W I
5
S+
A1A27
6
PNP
7 6NAMUR
7 6
5
+
A1A27
6S
5
+
A1A27
6S
PNP
7 6NAMUR
7 6
CEA-226
E
A
0,1s-990ss
6A 250VA
10
9 8 7 522243234
1131
621A2 A1
2+
314
412
111
R18 16
15
28 26
25
CEA-226 / ....
AC220-240V ATX
AC110-120V ANP
UC24-48V UFK
UC12V UCB
DC110-240V DNX
204
4
16
C-A2
FOR PLUG-INMODULES
(M4)
9FS-23
78
38
x72
cm
Ordering no.
Ordering example
Timer CPX-519/ANXSocket C11A
DigitalMultifunctional Time Delay Relay• with digital time elapsed display• 5 functions• 2 change-over contacts• potential-free triggering
Digital Cycle Timer• Rest interval can be set separatley• digital time elapsed display• 2 change-over contacts• potential-free triggering
Time Delay Relay• 2 change-over contacts• potential-free triggering
Function (page)
System socket C11AFigure: with plug-in neutral conductorconnector C-A2 (standard delivery).
DiagramConnectionwith socket C11A
Time rangePartial range
Triggering Triggering
Time Delay RelayField proven since many years.The plug-in timer series from comatfor highest quality requirements andunattained versatile operation.
and otheres:www.comat.ch
Plug-in Time Delay Relay
78 KAT2008
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.
Function Page: 52; TF-60 setting: Page 53; Socket and Accessories: Page 97
CFG-126 CTI-129
2x 0,1s-15hs; min; h
CFG-126/ .... CTI-129/ ....
50/60Hz
AC/DC
DC 10%
E
CPX, CFGCTI
11
MAX
2x 0,01s-15mins; min
AC
UC
6A 250VA 6A 250VA
AC220-240V ATX
AC110-120V ANP
UC24-48V UFK
UC12V UCB
DC110-240V DNX
10
9 8 7 522243234
1131
621A2 A1
2+
314
412
111
R18 16
15
28 26
25
10
9 8 7 522243234
1131
621A2 A1
2+
314
412
111
R18 16
15
28 26
25
CPX-129
0,1s-15hs; min; h
CPX-129/ ....
6A 250VA
AC220-240V ATX
AC110-120V ANP
UC24-48V UFK
UC12V UCB
DC110-240V DNX
10
9 8 7 522243234
1131
621A2 A1
2+
314
412
111
R18 16
15
28 26
25
E
A K N
W G
H
F
AC220-240V ATX
AC110-120V ANP
UC24-48V UFK
UC12V UCB
DC110-240V DNX
I
5
S+
A1A27
6
5
S+
A1A27
6
PNP
7 6NAMUR
7 6
5
+
A1A27
6S
5
+
A1A27
6S
PNP
7 6NAMUR
7 6
204
4
16
C-A2
FOR PLUG-INMODULES
(M4)
9FS-23
78
38
x72
cm
Ordering no.
Ordering example
Multifunctional Time Delay Relaywith 3 double functions• individual setting of t1/t2• 2 change-over contacts• potential-free triggering
Multifunctional Time Delay Relay• 5 functions• 2 change-over contacts• potential-free triggering
Timer CPX-129/ATXSocket C11A
Function (page)
Time rangePartial range
System socket C11AFigure: with plug-in neutral conductorconnector C-A2 (standard delivery).
DiagramConnectionwith socket C11A
Multifunctional Cycle Timer• Reset interval can be set separate• 2 change-over contacts
Time Delay RelayField proven since many years.The plug-in timer series from comatfor highest quality requirements andunattained versatile operation.
Triggering Triggering
and otheres:www.comat.ch
Plug-in Time Delay Relay
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
79 KAT2008
Tim
e D
elay
Rel
ays
2
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.
Function Page: 52; TF-60 setting: Page 53; Socket and Accessories: Page 97
CWR-102
CWR-102/ ....
50/60Hz
AC/DC
DC 10%
E
CEA, CWR11
MAX
0,1-1,5s
AC
UC
6A 250VA
10
9 8 7 522243234
1131
621A2 A1
2+
314
412
111
R18 16
15
28 26
25
CEA-126
0,1s-15mins; min
CEA-126/ ....
6A 250VA
AC220-240V ATX
AC110-120V ANP
UC24-48V UFK
UC12V UCB
DC110-240V DNX
10
9 8 7 522243234
1131
621A2 A1
2+
314
412
111
R18 16
15
28 26
25
AC220-240V ATX
AC110-120V ANP
UC24-48V UFK
UC12V UCB
DC110-240V DNX
Q
W N
5
S+
A1A27
6
5
S+
A1A27
6
PNP
7 6NAMUR
7 6
5
+
A1A27
6S
5
+
A1A27
6S
PNP
7 6NAMUR
7 6
204
4
16
C-A2
FOR PLUG-INMODULES
(M4)
9FS-23
78
38
x72
cm
E
A
Ordering no.
Ordering example
Timer CEA-126/ATXSocket C11A
Single Shot Relay• 3 functions• function t1 = t2• 2 change-over contacts• potential-free triggering
Multifunctional Time Delay Relays• on delay or off delay• 2 change-over contacts• potential-free triggering
Function (page)
Plug-in Time Delay Relay
Time Delay RelaysField proven since many years.The plug-in timer series from comatfor highest quality requirements andunattained versatile operation.
and otheres:www.comat.ch
Time rangePartial range
Triggering Triggering
DiagramConnectionwith socket C11A
System socket C11AFigure: with plug-in neutral conductorconnector C-A2 (standard delivery).
80 KAT2008
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.
Function Page: 52; TF-60 setting: Page 53; Socket and Accessories: Page 97
CX 39
CX 39/ ....
50/60Hz
AC/DC
DC 10%
E
CX11
MAX
t 0,1s-15ht - 1-100ms
AC
UC
6A 250VA
10
9 8 7 522243234
1131
621A2 A1
2+
314
412
111
R1
18 16
15
28 26
25
5
S+
A1A27
6
CX 38
0,1s-15hs; min, h
CX 38/ ....
6A 250VA
AC220-240V ATX
AC110-120V ANP
UC24-48V UFK
UC12V UCB
DC110-240V DNX
10
9 8 7 522243234
1131
621A2 A1
2+
314
412
111
R18 16
15
28 26
25
AC220-240V ATX
AC110-120V ANP
UC24-48V UFK
UC12V UCB
DC110-240V DNX
5
S+
A1A27
6
5
+
A1A27
6S
5
+
A1A27
6S
5
+
A1A27
6
S
H
GF
R2R1 ( )R2 ( )
D
S
E
Y =
=
204
4
16
C-A2
FOR PLUG-INMODULES
(M4)
9FS-23
78
38
x72
cm
Ordering no.
Ordering example
Timer CX 38/ATXSocket C11A
Function (page)
Star-Delta Timer• adjustable - change-over
pause.• On delay with instantaneous
contacts(R1 = immediately / R2 = t)
• 2 change-over contacts
Time Delay RelaysElectronic Timer Relay with mains triggeringand 2 change-over contacts.Digital timing generated with RC-Oscilatorand frequency conductor with LED indicationof relay function.
and otheres:www.comat.ch
Multifunctional Time Delay Relays• 3 functions• delay time ranges can be set
individual• 2 change-over contacts• mains triggering
Time rangePartial range
Triggering Triggering
DiagramConnectionwith socket C11A
System socket C11AFigure: with plug-in neutral conductorconnector C-A2 (standard delivery).
Plug-in Time Delay Relay
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
81 KAT2008
Tim
e D
elay
Rel
ays
2
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.
Time delay Relays
DIN Time Delay Relays
• Multifunction Time Delay Relays• Extra slime Time Delay Relays 13mm• DIN-A (Installation, distribution panel)• DIN-C (Industry)• 22,5mm Seies
82 KAT2008
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.
Function Page: 52; TF-60 setting: Page 53; Socket and Accessories: Page 97
S+
A1A2
S
+
A1A2 B1
CRA1 / ....V
A
0,5s-30mins, min
CRE1
CRE1 / ....V
E
CRA1
0,3s-30min.s, min
+A2 A1
17 18
R
, AC115VAC230V
AC115V
UC24V
AE2 / ....VAE2M / ....V
A
AA2 / ....VAA2M / ....V
E
18
15
+
16
R
A1
A2 18
15
+
16
R
B1A1
A2
+
AE2 0,8s -1,5minAE2M 0,1-12min
AA2 0,8s -1,5minAA2M 0,1-12min
AE2AE2M
AA2AA2M
AC220-240V
AC110-127V
UC24V
CY1
CY1 / ....V
Y
+
28
17
18
A1
A2
UC110-240V
UC24-60V
752,
5
17,54,2
45
8
TS
35
5 44 20
CY1
90
13
BS13-KBS13-G(incl.paper)
TS
35
44
45
11
t 0,5-60st - 50/100ms
A2 A1
15 18
16 B1
+
R
E
DIN
6A 250VA 6A 250VA 10A 250VA 6A 250VA10A 250VAMAX
AC230V
AC115V
UC24V
AC220-240V
AC110-127V
UC24V
CRE, CRAAE, AA, CY
AC 50/60Hz
UC AC/DC
Economy time delayrelay• on delay• voltage controlled• LED for R.
Economy timedelay relay• off delay• votage controlled• LED for R
Function (page)
Triggering
Triggering
Economytime delay relay• off delay• voltage controlled• 1changeover contact• Output-LED
Economytime delay relay• on delay• voltage controlled• 1changeover contact• Output-LED
Star-deltatime delay relay• with adjustable
interval• Safety locking of the
ouput
Economy Time Delay RelaysOnly 13 or 17,5mm wide.Ideal for applications with afixed function E, A or Y.For snap-on installation inaccordance with DIN 43880.
Time range TF60 setting (page)
DIN Time Delay Relays (mono-function)
Ordering no.
Ordering example
Timer CRE1/AC230V
and otheres:www.comat.ch
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
83 KAT2008
Tim
e D
elay
Rel
ays
2
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.
Function Page: 52; TF-60 setting: Page 53; Socket and Accessories: Page 97
S+
A1A2
S
+
A1A2 B1
CRV1 CRV2 CRV3 CRT3CSV2
WE B PI
CRV1 / ....V CRV2 / ....V CSV2 / ....V
F O
8ms-10hs, min, h
K
W
A
E
N
0,5s-30mins, min
CRV3 / ....V CRT3 / ....V
t1: 50ms-60ht2: 50ms-60h
0,05s-60hs, min, h
+A2 A1
17 18
R
123
Z2Z1
100k
max. 50m
EXT POT
CSV2
S+
A1A2 B1
90
13
BS13-KBS13-G(incl.paper)
TS
35
44
45
11
+A2 A1
15 18
16 16
R
A2 A1
15 18
16 B1
+
RZ1 Z2
+A2 A1
B1+
O
KR
EXT POT
A2 A1
15 18
16 B1
+
R
E
K
W
A
E
N
B B2E
E
1
2
3
45 6
7
8
910
DINCRV, CSVCRT
t1: 50ms-60ht2: 50ms-60h
6A 250VAMAX 6A 250VA 1,5A 24VD 6A 250VA 6A 250VA
AC230V
AC115V
UC24V
AC230V
AC115V
UC24V
AC230V
AC115V
UC24V
AC230V
AC115V
UC24V
DC24V
DC 10%
AC 50/60Hz
UC AC/DC
CRV3CRT3
Multifunctional TimeDelay Relaylike CRV2, but withsolidstate ouput andconnection for remotepotentiometer.
Economy Time Delayand Blinker Relay• 3 functions• voltage controlled• LED for R
Universal Multifunc-tional Time Delay Relay• 2 delay functions• 2 shot timing modes• pulse shaping K• LED for B1and R
Double Time DelayRelay• F (E and A) or
(W and N)• t1/ t2 separately
settable• LED for B1and R• Function switch at the
right side of the device
Universal RepeatCycle Timer• Pulse or pause start• t1/ t2 separately
settable• LED for A1and R• Function switch at the
right side of the device
Extra slim 13mmTime Delay Relay Systemfor all timing functions from50ms up to 60 hours.With only 13mm fitting widthespecially suited for use in theindustrial inter-face sector.
Built-inpotentiometerSP-01/100k(page)
Triggering
Time range TF60 setting (page)
Multifunctional Time Delay Relays
Ordering no.
Function (page)
Triggering
Ordering example
Timer CRV1/AC230V
and otheres:www.comat.ch
13mm SLIM BUT.....
Function:I / P
Function:F / Q
84 KAT2008
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.
Function Page: 52; TF-60 setting: Page 53; Socket and Accessories: Page 97
S+
A1A2
S
+
A1A2 B1
S+
A1A2 B1
A K
AM1 / ....V
AM1 AM3
0,5s-60min0,5-6s...5-60min
0,5s-60min0,5-6s...5-60min
AM2 / ....V AM3 / ....V
E W B B2
+
R
18
15
16
A1
A2
AM2
W
E
+
R
18
15
16
B1A1
A2
+ +21
22 24
R R2
26 28
25
18
15
16
B1A1
A2
+R2=S R2=R (25-26-28)
45
8
TS
35
5 44 20
752,
5
17,54,2
A K
0,5s-60min0,5-6s...5-60min
W
E
AC220-240V
UC110-127V
UC24-60V,
E
DIN
752,
5
354,2
AC220-240V
AC110-127V
UC24-60V
10A 250VA 10A 250VA 10A 250VA
UC110-240V
UC24-60V
XXXXAM, CIM
16A 250VA
UC24-240V
CIM1/....V
CIM1
0,6s-60hsec, min, h
+
16
B1A1 A2
1815R
E
A K N B1 S LS
WB
AC 50/60Hz
UC AC/DC
MAX
Universal Time Delay Relaywith instantaneous contactor both contacts delayed(programmable).Functions like type AM2.Display of control input B1(S)in addition to the output-LED.
Economy Time Delay andBlinker Relay• on delay• one shot leading edge• 2 blinker functions• Output-LED
Universal Time Delay Relay• on delay• off delay• one shot leading edge• pulse shaping K• voltage controlled• Output-LED
17,5mmtime delay relay systemin compact design.Suited for snap-on installation inaccordance with DIN 43 880.CIM1 mit Treppenhausautomat undSchrittschalter.
Time rangePartial ranges
Triggering
Multifunctional Time Delay RelaysUniversal Function Relay
Ordering no.
Function (page)
Triggering
and otheres:www.comat.ch
Ordering example
Universal function relayCIM1/UC24-240V
Universal Function Relay• 9 functions• stepping switch (S)• staircase lighting timer (LS)• 1 change-over contact• hand function switch for
maintenance functions(ON/OFF)
NEW
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
85 KAT2008
Tim
e D
elay
Rel
ays
2
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.
Function Page: 52; TF-60 setting: Page 53; Socket and Accessories: Page 97
S+
A1A2
S
+
A1A2 B1
S+
A1A2 B1
CM1/....V
CM2
0,3s-12h0,3-3s...1,2-12h
A K W
E
A K W
E
CM2/....V
752,
5
17,54,2
LABEL
123
Z2Z1
100k
max. 50m
EXT POT
CM2
CM1
18
15
+
16
R
A1
A2
B1
+
UC110-240V
UC24-60V
UC110-240V
UC24-60V
+27
28 Z218
15
16
B1A1
A2
S R
Z1
EXT POT
RESE
T
STO
P
R
+
E
1
2
3
45 6
7
8
910
XXXX DINCM
6A 250VAMAX 6A 250VA
162/3...60Hz
LABEL
752,
5
354,2
CM3
50ms-60hms, s, min, h
5A 250VA
DC24-48V/AC24-240V
DC12-24V
B W
E
A K N B1
B1
16
+A2
18
A1
26 2825
15R
R
CM3/ ....V
CM1L
A K W
E
0,3s-12hs, min, h
50ms-100minms, s, min
6A 250VA
18
15
+
16
R
A1
A2
B1
+
UC110-240V
UC24-60V
162/3...60Hz
CM1L /....V
TS
35
5 1064
8
CM3
DC 10%
UC AC/DC
17,5mmTime Delay Relay Systemin compact design.(For snap-on installation inaccordance with DIN 43 880,see series DINA and C13.)
Universal Time Delay Relay• on delay• off delay• one shot leading edge• pulse shaping K• voltage controlled• LED for B1 and R
Universal Time Delay Relaylike type CM1, but with timestop and reset inputas well asconnection for remotepotentiometer 100k.2 heavy current contacts.
Built-inpotentiometerSP-01/100k(page)
Time rangePartial ranges
Triggering
Multifunctional Time Delay Relays
Ordering no.
Function (page)
Triggering
and otheres:www.comat.ch
Ordering example
Timer CM1/UC110-240V
Universal Time Delay Relay• 7 functions• Mainenance switch ON/OFF• 2 seperate change-over
contacts• supply voltages:
DC12-24V orDC24-48/AC24-240V
Universal Time Delay Relaylike type CM1, but with exten-ded time range.
OUR BEST
HORSE
86 KAT2008
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.
Function Page: 52; TF-60 setting: Page 53; Socket and Accessories: Page 97
S+
A1A2
S
+
A1A2 B1
S+
A1A2 B1
CNR1 / ....V
CNR1
I PNA
CT1/....V
CT1
+
R
18
15
16
A1
A2
+
R
18
15
16
A1
A2
UC110-240V
UC24-60V
UC110-240V
UC24-60V
E
t1: 0,1s-12mint2: 0,5s-60min
t1: 0,5s-60mint2: 0,3min-30h
CT1L
I P
MAX 5A 250VA 6A 250VA 6A 250VA
+
R
18
15
16
A1
A2
UC110-240V
UC24-60V
CT1L /....V
0,1s-12minsec, min
DINCNR, CT
752,
5
17,54,2
LABEL
TS
35
5 1064
8
UC AC/DC
17,5mmTime Delay Relay Systemin compact design.(For snap-on installation inaccordance with DIN 43 880.
Time Delay Relay,no auxiliary voltage• Function runs after cut off
power supply• Minimum triggering time
150ms only
Universal Repeat CycleTimer• pulse or pause start• t1/t2 separately settable• LED for A1 and R
no auxiliary voltage
Time rangePartial ranges
Triggering
Multifunctional Time Delay Relays
Ordering no.
Function (page)
Triggering
and otheres:www.comat.ch
Ordering example
Timer CIM1/UC24-240V
Universal Repeat CycleTimerLike CT1 buth with extendedtime range.
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
87 KAT2008
Tim
e D
elay
Rel
ays
2
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.
Function Page: 52; TF-60 setting: Page 53; Socket and Accessories: Page 97
ECO32 / ....VECO31 / ....V
ECO31
WE B
70
90
22,5
2
1
23
45678
9
10 TS
35
WE B
KA N
0,5s-20minsec, min
0,1s-12h sec, h
A2 A1
16 18
+
15
R
A2 A2 A1
16 18
+
15
R
B1
S+
A1A2
S
+
A1A2 B1
AC230V
AC115V
UC24V
E
XXXX DINECO
MAX 6A 250VA 6A 250VA
AC230V
AC115V
UC24V
AC 50/60Hz
UC AC/DC
Multifunctional Time Delay Relays
Economy Time Delay andBlinker Relay• 3 functions• voltage controlled• LED for R
MultifunctionalTime Delay Relay• 2 delay functions• 2 shot timing modes• blinker pulse shaping K• LED for R
MultifunctionalTime Delay Relays 22,5mmfor timing functions from0,1s up to 12 hours.
Triggering
Time range TF60 setting (page)
Function (page)
Triggering
Ordering no.
and otheres:www.comat.ch
Ordering example
Timer ECO31/AC230V
88 KAT2008
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.
Comat products comply with different international standards and are certified accordingly.
A detailed list can be found on our web page:
www.comat.chLloyd’s; IEC 61810; EN 60974
Notes
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
89 KAT2008
Tim
e D
elay
Rel
ays
2
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.
Time Delay Relays
Specially Time Delay Relays
• CN Series Specially Time Delay Relays• SFR Serie Amplifier Relays, Switching Amplifier• SBV Amplifier Blinker• CPF Pulse Shaper• CCX Preset Counters
90 KAT2008
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.
Function Page: 52; TF-60 setting: Page 53; Socket and Accessories: Page 97
CNS, CN DIN
CNS-4 CN 135
E
MAX
0.1s-30mins, min
6A 250VA
S
+
A1A2 B1
S+
A1A2 B1
CNS-4 / ....V
AC220-240V ATX
AC110-120V ANP
UC24-48V UFK
EXT POT
B1
15
A1
R1
18
A2
25 28 35 38 45 48
R2 R3 R4
15
16
A1
A2
R
18 26 28 Z1 Z2
25 Y1 Y2 B1
R
S+
A1A2 B1
Y1 Y2
A1A2 B1
Y1 Y2
S
+
CN 135 / ....V
AC220-240V ATX
AC110-120V ANP
UC24-48V UFK
0.1s-30mins, min
8A 250VA
123
Z2Z1
1M
max. 50m
EXT POT
CN135
1
2
3
45 6
7
8
910
E4
EA4
t t t t t t t tS
R1R2R3R4
t t t tS
R1R2R3R4
E4
EA4 A
E
AC 50/60Hz
UC AC/DC
Industrial Time Delay Relays
Ordering example
Cascade Relay CNS-4/ATX
and otheres:www.comat.ch
Built-inpotentiometerSP-01/1M(page)
Time rangePartial range
Function (page)
Triggering
Triggering
Ordering no.
On delay
On delayOff delay
Cascade Relay• ON cascades• ON/OFF cascades• 4 outputs• detachable terminals
Specially Time Delay Relays• 2 functions• connections for external potentiometer
1 M• 4 outputs• detachable terminals• seismic approved according IEE 323
and IEE 344
Industrial Time Delay RelaysCN135 with 2 change-over contacts.CNS-4 with 4 independent outputs.
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
91 KAT2008
Tim
e D
elay
Rel
ays
2
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.
Function Page: 52; TF-60 setting: Page 53; Socket and Accessories: Page 97
CU
CU23
E
MAX 120mA 24VD
CU23 / ....V
DC12-24V
0.01s-300mins, min
min s
10 1 2 3 4
67
8
9
12
13
14
15
NPN
PNP
120
mA
Ct
ST
OP
10-28V
t
NAEK
S
Rt
–
150
mA
R
+ -
R
t x1 x6 x30
+
+
–
5 17 18 19 20 11
CU23
1
2
3
45 6
7
8
910
S+
10 11 510
S
11 5
+
E
A K N W
6 7 8 9 10
E
6 7 8 9 10
A
6 7 8 9 10
K
6 7 8 9 10
W
6 7 8 9 10
N
DC 10%
0,01-3s0,01-0,1s0,06-0,6s0,3-3s
0,05-30s0,05-1s0,3 - 6s1,5-30s
0,05-30m0,05-1min0,3 - 6min 1,5-30min
1-300min1- 10min6-60min30-300min
15
6K8
100K
14
1M
14
1M
15
1 M
100K560nF
sec18 19
min17 19
x1 1 2 x6 1 3x30 1 4
Ordering example
Timer module CU23/DC12-24V
Built-in potentiometer (page)SP-01/100kSP-01/1M
Ordering no.
Universal Timer Modulewith soldering pins for printedcircuit mounting.
Wiring (view from the back)
Universal Timer Module
and otheres:www.comat.ch
Universal Timer Modulefor Print Mounting• the time module for industrial
application• 5 functions• t-stop• PNP/NPN output
Example for external wiring
Time rangePartial range
Series resistor Rv
Extender capacitor Ct
Adjustable resistor RtTime rangePartial range
Function (page)
Triggering
Programming
Time stop (t -STOP) = the elapsing time is interrupted
Triggering
92 KAT2008
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.
Function Page: 52; TF-60 setting: Page 53; Socket and Accessories: Page 97
SFR1 SFR2
SFR1/ .... SFR2/ ....
SFR11
5A 250VAMAX 6A 24VU
50/60HzAC AC/DCUC AC220-240V AC110-120V UC24V
10
9 8 7 522243234
1131
621A2 A1
2+
314
412
111
R
D
D
D
10
9 8 7 522243234
1131
621A2 A1
2+
314
412
111
R
204
4
16
C-A2
FOR PLUG-INMODULES
(M4)
9FS-23
92
38
x72
cm
Ordering no.
Ordering example
Amplifier relay SFR1/AC220-240VSocket C11A
System socket C11AFigure: with plug-in neutralconductor connector C-A2
(standard delivery).
Amplifier Relay• switching amplifier for:
- PNP 3 wire sensors- NAMUR sensors
• potential-free contact• integrated sensor supply voltage 24V• The input wiring is specifically suitable for
long connection lines
Amplifier RelaySupply unit with integrated switching amplifier for3-wire PNP sensors, NAMUR as per DIN 19234 aswell as for contact triggering also with externalpower supply.The input wiring is specifically suitable for longfeed wires.
Amplifier Relay• switching amplifier for:
- PNP 3 wire sensors- NAMUR sensors
• potential-free contact• integrated sensor supply voltage 14V• The input wiring is specifically suitable for
long connection lines
Output supply DC output supplyOutput voltage DC 22...25V DC 14V
Output current max. 100mA 4mA
Triggering NAMUR sensorNot damped output active output active
Damped output inactive output inactiveWire break output inactive output inactive
PNP three-wire sensor
External power supply/contactOn-signal DC +18...+30V DC +10...+30VOff-signal DC –30...+7,5V DC –10...+5V
triggering current 7mA bei DC24V 7mA bei DC24VParallel load energy 100V 10ms/1Hz 100V 10ms/1Hz
Galvanic isolation >2kV (triggering to supply and output) >2kV (triggering to supply and output)>2kV (triggering to supply and output)
DiagramConnection with socket C11A
and otheres:www.comat.ch
Amplifier Relays
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
93 KAT2008
Tim
e D
elay
Rel
ays
2
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.
Function Page: 52; TF-60 setting: Page 53; Socket and Accessories: Page 97
SBV11
SBV11/ .... SSV11/ ....
DC 10%
SBV11
10A 10-45VDMAX
DC24-48V DC12-36V DC12-36V
K
60
70 80
90
SSV11
K
UB 10...45VIS 5...15 mAIRL max. 10 A
B
60-90 I/min
+
S
K
S
832
A210
724
621
522
412
349
A12
3111
111
143
+
SK
+
A210
349
A12
3111
111
143
832
724
621
522
412
10A 10-45VD
38
x72
cm
Ordering no.
Ordering example
Amplifier relay SBV11/DC12-36VSocket CS11
Amplifier-BlinkerWith solid state output.Adjustable electronic flasher for 60-90 pulses/min.Switching voltage 10-45V DC and switching loads upto 10A. The short circuit limiter and the overload proofdesign alows wear free switching of filament lamps ingeneral but as well as all ohmic, inductive and capacitiveloads.Triggering supply is indicated by LED.
Blinker and AplifierRelay with solid state output specially suitable forfrequent switching cycles.
DiagramConnection with socket CS11
Switching AmplifierWith solid state output.For applications in automation where high switchingcycles and loads up to 10A at 10-45V DC are required.For example for solenoids, magnetic clutches and otherohmic inductive or capacitive loads. With built-in shortcircuit limiter and over-load protection circuit, this amplifierswitches wear free and guarantees high service life.LED display for trigger signal.
Amplifier
Blinker
Amplifier Relays
and otheres:www.comat.ch
Time range
Function (page)
94 KAT2008
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.
Function Page: 52; TF-60 setting: Page 53; Socket and Accessories: Page 97
CPF11 CPF22
AK L K A
FD
E1
++ E2
O
3K3
K
PN
P
S
RL
0,8A
4K7
15÷32VD
CPF22 / ....VCPF11 / ....V
TS
35
5 1064
8
CPF22
CPF11
752,
5
17,54,2
+11K
PNP
1S
1RL
2E21E21E1 2E1
1O 2O+
5K6
2S
+ 2RL
150mA
+
4kV
10÷45VD
15÷32VD
DC24V DC24V
15…32V
E1
SPNP
CPF
+ +19…28V
E1
SNAMUR
CPF
E2+ +
DINCPF
DC 10%
Pulse Shapers
CPF Pulse Shaperswith the timing functions K, L and A are specialistdevices for the lengthening or the limitation of controlpulses. In this fully electronic design with the facility foralso con-necting NAMUR sensors they are the idealinterface modules in modern control systems.Always there where fast processes, high rotations, i.e.the briefest pulses, are to be evaluated, the cost-effective solution is: CPF Pulse shapers.
input pulse output pulse≥1/5ms 5÷600ms
input pulse output pulse≥0,5/2,5ms 50/200ms
Double Channel Pulse Shaper• Input /output galvanically
isolated 4kV• Input and output times separately
settable• 2 functions to choose• LED output display for each
channel
Single Channel Pulse Shaper• Input reversible (E-E)• Input and output times separately
settable• 3(6) functions to choose• Additional free wheel diode 1A• LED display for E and Q
Three-wire sensorNAMUR sensor
Ordering no.
and otheres:www.comat.ch
Time range
Ordering example
Pulse shaper CPF11/DC24V
Function (page)
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
95 KAT2008
Tim
e D
elay
Rel
ays
2
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.
Function Page: 52; TF-60 setting: Page 53; Socket and Accessories: Page 97
CCX-550
CCX-550/ ....
CCX11
MAX
50/60HzAC
AC/DCUC
6A 250VA
CCX-350
0-999200Hz
CCX-350/ ....
6A 250VA
AC220-240V ATX
AC110-120V ANP
UC24-48V UFK
AC220-240V ATX
AC110-120V ANP
UC24-48V UFK
CE CK CI CE CK CI
0-999200Hz
CE
U
C
R
Q
1 1n
CK
U
C
R
Q
1 1n
CI
U
C
R
Q
1 1n n1
t
ONOFF8
32
A210
Q
724
621
522
412
349
A12
3111
111
143
OUTPUT
RESETRCCOUNT
NAMUR7 6
PNP
7 6
832
A210
Q
724
621
522
412
349
A12
3111
111
143
OUTPUT
RESETRCCOUNT
NAMUR7 6
PNP
7 6
38
x72
cm
Ordering no.
Ordering example
Counters CCX-350Socket CS11
Preset Counters
and otheres:www.comat.ch
Preset Counters with displaySwitching after the preset number ofpulses are reached.• 7 digit LED display
Triggering:• potential-free contact• NAMUR sensor• PNP
Preset CountersElectronic pre-select counter with 2change-over contacts.Digital value display with LED functionindication.Suitable for front panel mounting.
Preset CountersSwitching after the preset number ofpulses are reached.
Triggering:• potential-free contact• NAMUR sensor• PNP
Functions
Q is active after reaching the preselected number ofpulses.Q and C can be reset with the reset button.
Q is active during the preselected number of pulsesand can only be reactivated after a reset.Q and C can be reset with the reset button.
Q is active for t75.. .125ms on the preselectedpulse.The cycle starts again at the beginning.Q and C can be reset with the reset button.
U = VoltageC = CountR = ResetQ = Output relays
DiagramConnection with socket CS11
PreselectionCount frequency
Function
96 KAT2008
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.
Comat products comply with different international standards and are certified accordingly.
A detailed list can be found on our web page:
www.comat.chLloyd’s; IEC 61810; EN 60974
Notes
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
97 KAT2008
Tim
e D
elay
Rel
ays
2
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.
Time Delay Relays
Sockets and Accessories for Time Delay Relays
Sockets for Time Delay Relays• Economy Sockets • System Sockets• Chassis Sockets• Accessories pour Sockets
Accessories for Time Delay Relays• External Potentiometer• Surface Mounting Case• Divers
98 KAT2008
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.
Function Page: 52; TF-60 setting: Page 53; Socket and Accessories: Page 97
8 11
7
3
5 4
11
8
1
6
9
9 7
6
5 4 3
11
8
1
A
B
C11ASystem socket 11-pole,with white cover andplug-in connector C-A2.(standard delivery)
EC11Economy socket11-pole
EC8Economy socket8-pole
CS8Socket8-pole
Socket for Time Delay Relays
CS11Socket 11-poleSnaped cover sheet withwiring diagram.(backside neutral white)
C12BSystem Socket 11-pole,12 terminals (+B1).SC-3 inserted for B1-2-A1.Cover transparent.
C12B1System Socket 11-pole,like C12B, but with im-printed contact diagram for3 pole industrial relays.
CS18Socket 8-polefor time delay relaysC81...C85 series.
11 PGLSocket 11-polefor chassis mounting withsoldering pins.
C12B0System Socket 11-pole,similar to C12B.Prepared for CT system(without SC-3, SD-1).
Socket types Suitable for product families
C11A System-Sockel A
EC-11 Economy-Socket A
CS-11 Socket B
C12B System Socket A
C12B0 System Socket A
C12B1 System Socket A
CS-18 Socket –
CS-8 Socket –
EC-8 Economy Socket –
11 PGL Chassis Socket – recommended applicable
CT3.
..CS
...C5
0...
C60.
..RS
...C.
..CX
...SS
R...
CCX.
..
CT30
...CT
36
CT2
C81.
..C85
Connection layout(from left to the right)
Socket
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
99 KAT2008
Tim
e D
elay
Rel
ays
2
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.
Function Page: 52; TF-60 setting: Page 53; Socket and Accessories: Page 97
TS
35
20
15
4
ø 5
,3
3
32 24 21 22 12
8 7 6 5 4
7 5
34
9
A2
10 11
31 11
1
A1
2 3
14
LAB
ELS
29,5
TEST
3,2
8
38
CA-11
SL-36
SP-36
CA-8
CS-8 CS-11
68
C12..C11..
CONNECTOR C-A2
SD-1SD-1W
C-A2
SC-3
L-16
75
38
M3
S+S, wieland
A2-CONNECTOR
max 40
FOR PLUG-INMODULES
11 16
A2
10 2
5789 43
31 2 4 5
B1
12
30
FOR M4
A1
20 4
4
16
C-A2
10
TS
35
LH-1
22,5
21
1324
11
8 756B1A2 A1
24 1222 14
2
4
6
8
1
3
5
7CS-18SWISS
22,5 3,5
formodules
75
SS-T
CS-18
SS-W
PS-W
SA-0forM314
6
18
22 4
56 4 3
187 2
24 22 1412
11A2 21 A1
28
38
8
62
M4M3
23
EC-8
38
28
24.2
11 1610 2
34 32 24 22 14 12
11A2 31 21 A1
forM4
forM3
9 8 7 5 3 4
EC-11
8
62
EC8 EC11
Socket accessories Socket types
Type Description C11A EC-11 CS-11 C12B C12B0 C12B1 EC-8 CS-8 CS-18
CA-11 Coding ring (VE 5 pieces)
CA-8 Coding ring (VE 5 pieces)
C-A2 Neutral connector bridge (VE 5 or 50 pieces)
SC-3 A1-Connector (VE 10 pieces)
LH-1 Marking lable holder (VE 5 pieces)
SL-36 Marking lable holder (VE 5 pieces)
SP-36 Marking lable strips (VE 5 pieces)
PS-W Marking lable strips (VE 5 pieces)
L-16 Marking lable strips (VE 5 pieces)
SD-1 Cover lid transparent (VE 5 pieces)
SD-1W Cover lid white
SS-T Cover transparent
SS-W Cover white
SA-0 Wall braket
Socket accessories and dimensionsSockets
100 KAT2008
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.
Function Page: 52; TF-60 setting: Page 53; Socket and Accessories: Page 97
PLUG-IN MODULE
FS-23FS-40
FA-50
FS-CFS-RFS-xx
68
1,5 .. 5
18
KLEMMFEDERRETAINING CLIP
36
45+
0,6
0
33 +0,6 0
48
FRONT
FRONTRAHMEN
FRONT FRAME
22
SOCKEL
SOCKET
SET No.FZ-50L
BS13-KBS13-G
GC-TGC-W
HF-24
SW
ISS
HF-50
1
2
3
45 6
7
8
9
10
30
42,6
IP65
1...6
56 36
FERNPOTENTIOMETERREMOTE POTENTIOMETER
SP-01/1M
22…23
SP-01/100K
1 2 3
1M100K
12
3
9
15,5
1..3
42
72
FRONT
70+
0,6
0
38 +0,6 0
75 / 89
FRONTRAHMENFRONT FRAME
KLEMMFEDERRETAINING CLIP
SET No.FZ-23
15,5 1282
8
49
5040,5
+0,
6
0
36,5 +0,6 0
FRONT
1..4FRONTRAHMENFRONT FRAME
KLEMMFEDERRETAINING CLIP
SET No.FZ-40
PLUG-IN MODULE
INDUSTRIAL RELAY
C-A2
HF-32S3-C
FS-RFS-C
FS-C5
INDUSTRIAL RELAY
HF-33S3-CT
TIME CUBE
External potentiometer Front panel mounting FZ-50LConsisting of front frame with cover, retaining clips and socket (11 PGL).
Accessories pour Time Delay Relays
Front panel mounting FZ-23Consisting of front frame with cover, retaining clips.
Front panel mounting FZ-40Consisting of front frame with cover, retaining clips.
Marking labelsLarge and small for relay system C13.
Transparent covers Retaining clipsMatching diverse cases and sockets.
Retaining clipsMatching diverse cases and sockets.
Accessories
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
101 KAT2008
Tim
e D
elay
Rel
ays
2
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.
Function Page: 52; TF-60 setting: Page 53; Socket and Accessories: Page 97
RS...
C...
CX
CC
xSS
R
CS.
..C
50...
C60
...
CT3
0...
RS 4
0
CT2
...
CT3
...
C80
...
C13
...
DIN
A
DIN
B/C
RG - .. . RG - .. .
Socket
. . . mm
94
4,5
RG
50
125
97
83,5
7,5
3 3
TS
35 96
67243 3
97
96
Accessories for time delay relays and AP-surface mounting case Product families
Accessories pour Time Delay Relays
Type Descriptions
BS13-G Marking label strip large
BS13-K Marking label strip small
FA-50 Front cover
FS-23 Front cover
FS-40 Front cover
FS-C5 Cover for relay C30
FS-R Cover for relay C3-..
FS-.. Cover for relay C5-..
FZ-23 Front mounting set
FZ-40 Front mounting set
FZ-50L Front mounting set (incl. Socket 11PGL)
GC-T Relay retaining clip transparent
GC-W Relay retaining clip white
HF-24 Retaining clip
HF-32 Retaining clip for relay C30
HF-33 Retaining clip for relay C20/C30
HF-50 Retaining clip
S3-C Retaining clip for relay C3
S3-CT Retaining clip for relay C2/C3
RG Surface mounting case DIN rail
RG-D2 Surface mounting case DIN rail
RG-C2 Surface mounting incl. Socket CS-8
RG-C3 Surface mounting incl. Socket CS-11
RG-50 Surface mounting incl. Socket CS-11
RG-23 Surface mounting incl. Socket CS-11
RG-40 Surface mounting incl. Socket CS-11
Accessories
External potentiometer
Type Time delay relays
SP-01/100k CSV2 CM2
SP-01/1M CS1 CS2 RS 121.P CN 135
Surface Mounting Case with built-in DIN rail or with socket (Screws touch safe)Gray polymer with or without window..
Type Socket W x HRG DIN ---RG-D2 DIN 21 x 46 mmRG-C2 CS-8 36 x 36 mmRG-C3 CS-11 36 x 36 mmRG-50 CS-11 36 x 50 mmRG-23 CS-11 39 x 73 mmRG-40 CS-11 37 x 40 mm
102 KAT2008
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.
Notes
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice. 103 KAT
2008
Inst
alla
tion
Rela
ys
3
• Power Relays• Step-on Step-off Relays• Staircase Lighting Timers• Power Step-on Step-off Relays• Installation Contactors
Installation Relays
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.104 KAT
2008COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
Notes
Lloyd’s; IEC 61810; EN 60974
Comat products comply with different international standards and are certified accordingly.
A detailed list can be found on our web page:
www.comat.ch
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice. 105 KAT
2008
Inst
alla
tion
Rela
ys
3Se
ries
Time r
ange
Conta
ct
Page
Sock
et typ
e
Step-on Step-off RelaysStaircase Lighting Timer
CIM1 0,6s-60min DIN 35 16A 106
Step-on Step-off Relay CRS1C DIN 35 6A 106
Power Relay B103 DIN 35 10A 107
Power Relay A333 DIN 35 10A 107
Staircase Lighting Timer AL1 30s -10min DIN 35 10A 108
Staircase Lighting Timer AL2 30s -10min DIN 35 10A 108
Staircase Lighting Timer AL3 30s - 60min DIN 35 10A 108
Staircase Lighting Timer for central control
AL4 30s -60min DIN 35 10A 109
Staircase Lighting Timer for central control
AL5 DIN 35 10A 109
Installation Contactor RIC20 DIN 35 20A 110
Installation Contactor RIC25 DIN 35 25A 110
Installation Contactor RIC40 DIN 35 40A 110
Installation Contactor RIC63 DIN 35 63A 110
AUX Block RIC-AUX 6A 110
Installation Relays
Step-on Step-off Relays
Power Relays
Staircase Lighting Timers
Staircase Lighting Timerfor central control
Installation Contactors
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.106 KAT
2008COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
Function Page: 52
S+
A1A2
S
+
A1A2 B1
S+
A1A2 B1
CRS1C
E
CIM1
+
16
B1A1 A2
1815R
E
A K N B1 S LS
WB
DINCIM, CRS
45
TS
35
5 44 20
752,
5
17,54,2
AgNi16A 250V4000VA // 384W30 x 106
AC ±20% / DC ±20%1,2VA, 430mW10ms / 10ms≤ 10mA
16A 250VA10mA 12V
MAXMIN
CIM1/UC24-240VUC
/
6A 250VA10mA 12V
90
13
BS13-KBS13-G(incl.paper)
TS
35
44
45
11
MAXMIN
CRS1C/AC230V
DC≤10%
AC50/60Hz
CRS1C/DC24V
0,6s-60h
13mm17,5mm
111214
12
A2 A1
+( DC-
vers
ion)
+
Function (page)
Step-On Step-OffRelays
Step-On Step-OffRelays
Type: AS1No longer availablesubstituted by CIM1
Step-On Step-off Relay• with integrated LED display• no external wiring required• Mounting on DIN rail TS35
Test voltage: 2000V
Tamb. operation/storage:-20..+60/-40..+85°CRailway version up to -46°
Step-On Step-Off Relay/Staircase Lighting Timerand 7 additional time functions includingON/OFF manual switch for maintenancepurpose.LED status display and integrated testswitch.
Step-On Step-Off Relay• with integrated LED display• no external wiring required• Mounting on DIN rail TS35
Test voltage: 2000V
Tamb. operation/storage:-20..+60/-40..+85°C
Step-On Step-Off Relay• 13mm series• 1 x CO for permanente drive• supply failure protected• Integrated LED and coil wiring
Time Range
Triggering
Triggering
and otheres:www.comat.ch
and otheres:www.comat.ch
Contact materialSwitching current /voltageSwitching power AC1 // DC1Switching cycles mech.
Operating voltagePower consumption AC/DCTriggering delay / release timeGlow lamp load
Data at Tamb =20°C
Contact materialSwitching current /voltageSwitching power AC1 // DC1Switching cycles mech.
Operating voltagePower consumptionTriggering delay / release time
AgNi15A/20ms1500VA // ...180WDC: 10 x106; DC ≥15%
AC ±15% / DC ±15%2VA 1,5WRecommended triggering time ≥50ms
Data at Tamb =20°C
Ordering example
Step-on step-off relayCIM1/UC24-240V
Ordering example
Step-on step-off relayCRS1C/AC230V
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice. 107 KAT
2008
Inst
alla
tion
Rela
ys
3
Function Page: 52
B103
DINB103, A333
AgCdo2200VA // ≤150W (DC)16A2x 107
AC ±15% / DC ±15%2VA, 1,5W20ms / 12ms
10A 250VA10mA 12V
MAXMIN
DC≤10%
AC50/60Hz B103 /AC .... V
B103 / UC .... V
220-240, 110-127
48, 24, 8-12UC50/60Hz /
A333
10A 250VA10mA 10V
AgCdo1500VA // ≤300W (DC)30A2x 107
0,8...1,1UN
2,2VA, 1,2W18ms / 10ms
A333/AC .... V
A333/ DC .... V
230, 110, 48, 24
48, 24, 12
+
11
12 14
A1
A2
R
11
12 14 22
21 31 32
24 34
A1
A2
+
R R R
A333
Ordering example
Power RelayB103/AC220-240V
Contact materialSwitching power AC1 // DC1Peak inrush currentSwitching cycles mech./elec. (AC1)
Operating voltage AC50Hz/DCPower consumption AC/DCTriggering delay / release time
Data at Tamb = 20°C
Connection lay out (top/bottom)
Power Relays• with mechanical output status• A333 with DIN 45mm cap dimension
Test voltage: 2000V 2000V
Tamb. operation/storage:-20..+60/-40..+85°C
Power Relay• 1 pole power relay with free-wheeling
diode and reverse polarity protection• Integrated LED position indicator
and otheres:www.comat.ch
Power Relay• 1 pole power relay with free-wheeling
diode and reverse polarity protection• Integrated LED position indicator
Power Relays Power Relays
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.108 KAT
2008COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
Function Page: 52
AL1
DINAL1... AL3
W+AgSnO2
2200VA // ≤440W (DC)120A /20ms3x 107
0,85...1,1UN
2,5VA50ms /≤300ms≤10mA
10A 250VA10mA 12V
MAXMIN
AC50/60Hz AL1/AC .... V
220-240, 110-127
UC50/60Hz /
AL2
10A 250VA (120A peak)
10mA 12V
W+AgSnO2
2200VA // ≤440W (DC)120A /20ms3x 107
0,85...1,1UN
2,5VA50ms/≤300ms≤ 40mA
AL3
10A 250VA (120A peak)
10mA 12V
W+AgSnO2
2200VA // ≤440W (DC)120A /20ms3x 107
0,85...1,1UN
2,5VA, 1,5W60ms/≤300ms≤ 40mA
AL2/AC .... V220-240, 110-127
AL3/AC .... V
AL3/ UC .... V
220-240, 110-127, 48-60
24
B1
tL
LS
S
Y1 Y2
Y2 Y3 t
SLSL
30s-10min 30s-10min 30s-60min
10mA
L
10 A
1200WN
17
18 18
B1A1
A2
R
40mA
L
10 A
1200WN
17
18 18
B1A1
A2
B1
A2
R
40mA
L
2000WN
17
18
A1
A2
Y1B1
18 Y4 Y5
Y2 Y3
N
R
10 A
LL
120A PEAK
Staircase Lighting Timers• Trigger status indication• Manual-Auto switch
Test voltage: 2500V
Tamb. operation/storage:-45..+60 /-45..+85°C
Staircase Lighting Timers
Staircase Lighting Timers• For small to medium-sized installations• Single contact 10A, 250Va• 30s-10min running time, infinitely
adjustable• subsequent time operation from zero• Manual ON
Staircase Lighting Timers
Staircase Lighting Timers• With special contact for high lamp loads• 120A special early make contact• Glow lamp load with AC• 30s-10min running time, infinitely
adjustable• subsequent time operation from zero• Manual ON
Staircase Lighting Timers• With stepping switch functions LS and S• 120A special early make contact• Glow lamp load with AC• 30s-1h running time, infinitely adjustable• subsequent time operation from zero• Manual ON
Staircase Lighting Timers
Contact materialSwitching power AC1 // DC1Peak inrush currentSwitching cycles mech./elec. (AC1)
Operating voltage AC50Hz/DCPower consumption AC/DCTriggering delay / release timeGlow lamp load
Data at Tamb =20°C
and otheres:www.comat.ch
Function/Triggering
Time Range
Function Triggering(Page)
Ordering example
Staircase Lighting TimerAL1/AC220-240V
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice. 109 KAT
2008
Inst
alla
tion
Rela
ys
3
Function Page: 52
AL4
DINAL4 ... AL5
W+AgSnO2
2200VA // ≤440W (DC)120A /20ms3x 107
0,85...1,1UN
≤ 2,5VA, 1,5W≤ 60ms/≤ 300ms≤ 40mA
10A 250VA (120A peak)
10mA 12V
MAXMIN
AC50/60Hz AL4/AC .... V
AL4/ UC .... V
220-240, 110-127, 48-60
UC50/60Hz /
AL4C
10A 250VA (120A peak)
10mA 12V
W+AgSnO2
2200VA // ≤440W (DC)120A /20ms3x 107
0,85...1,1UN
≤ 2,5VA≤ 60ms/≤ 300ms≤ 40mA
AL5
10A 250VA (120A peak)
10mA 12V
W+AgSnO2
2200VA // ≤440W (DC)120A /20ms3x 107
0,85...1,1UN
≤ 2,5VA, 1,5W≤ 60ms/≤ 300ms≤ 40mA
AL5/AC .... V
AL3/ UC .... V
230, 48-60
24
B1
tL
LS
S
Y1 Y2
Y2 Y3t
30s-60min 0,5s-60min40
mA
L
2000WN
17
18
A1
A2
CB1
18 Y2 Y3
C1 C2
N
Y1
ON RE
SET
AUTO
24-60V UC
R
40m
A
L
2000WN
17
18
A1
A2
B1
18 Y2 Y3
C1 C2
Y1
ON RE
SET
AUTO
CENTRAL+
R
L+
A2A3
C1 C2
ON
OFF
CENTRAL
A2N
Get
renn
ter S
teue
rkre
is.
(Spa
nnun
g w
ie A
1-A2
)
40m
A
2000WN
11
12
A1
A2
B1
12 A3
C1 C2
ON
OFF
CENTRAL
A2
R
L+
SLSLSLSL
24
AL4C/AC .... V220-240, 110-127
C2C1B1
R
AL4AL4C
AL5
S
120A PEAK
Ordering example
Staircase Lighting TimerAL4/AC220-240V
Contact materialSwitching power AC1 // DC1Peak inrush currentSwitching cycles mech./elec. (AC1)
Operating voltage AC50Hz/DCPower consumption AC/DCTriggering delay / release timeGlow lamp load
Data at Tamb =20°C
Staircase Lighting Timers• Trigger status indication• Electronic switch position indication
Test voltage: 2500V 1500V
Tamb. operation/storage:-20..+60 /-40..+85°C
Staircase Lighting Timersfor central control
Staircase Lighting Timers• Two-way lighting control on-off,
stepping switch• 120A special early make contact• AC supply for glow lamp• 30s-1h running time, infinitely adjustable• subsequent time operation from zero• Manual ON
and otheres:www.comat.ch
Staircase Lighting Timers• Two-way lighting control on-off,
stepping switch• 120A special early make contact• AC supply for glow lamp• 30s-1h running time, infinitely adjustable• subsequent time operation from zero• Manual ON
Power Step-on Step-off Relay• Stepping switch funct. S• Central ON-OFF• 120A special early make contact• Output status• Neon lamps by AC control
(Push button illumination up to 40mA for glow lamps resp. LED’s)
Power Step-on Step-offRelay for central control
Staircase Lighting Timersfor central control
Time Range
Function (Page) /Triggering
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.110 KAT
2008COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
Function Page: 52
RIC20 RIC25 RIC40 RIC63 RIC-AUX
20A 400VA10mA 24V
25A 400VA10mA 24V
40A 400VA10mA 24V
63A 400VA10mA 24V
6A 400VA5mA 24V
AgNi20A400V1,3kW/230V4kW/230V6002x105
0,85 - 1,1 UN
2,5W20ms // 20ms
AgNi25A400V2,2kW/400V16kW/400V6002x105
0,85 - 1,1 UN
3W10ms // 50ms
AgSnO240A400V5,5kW/400V26kW/400V1201x105
0,85 - 1,1 UN
5W20ms // 35ms
AgSnO263A400V8,5kW/230V40kW/400V1201x105
0,85 - 1,1 UN
5W20ms // 35ms
AgNi6A400V––6002x105
––– // –
RIC20-200/UC ..... V
RIC20-110/UC ..... V
RIC20-020/UC ..... V
24, 230UCA 50/60Hz / D
24, 230
24, 230
RIC25-400/UC ..... V
RIC25-220/UC ..... V
RIC25-040/UC ..... V
24, 230
24, 230
24, 230
RIC40-400/UC ..... V
RIC40-220/UC ..... V
RIC40-040/UC ..... V
24, 230
24, 230
24, 230
24, 230RIC-AUX20
RIC-AUX11
RIC-AUX02
A1 31
A2 42
A2 R22
A1 R11
R3A1R1
R4A2R2
A1 531 7
A2 642 8
A1 R3R11 3
A2 R4R22 4
A1 R5R3R1 R7
A2 R6R4R2 R8
A1 531 7
A2 642 8
A1 R3R11 3
A2 R4R22 4
A1 R5R3R1 R7
A2 R6R4R2 R8
A1 531 7
A2 642 8
6151
6252
6252
6151
6151
6252
RIC20 RIC25-63
UCA 50/60Hz / D
UCA 50/60Hz / D
TS35
RIC20
17,5 35
RIC25
54.5
RIC40RIC63
85
8
RIC-
AUX
TS35
45
44 (45.5*) 16.55
1.5*
A1 R3R11 3
A2 R4R22 4
RIC63-400/UC ..... V
RIC63-220/UC ..... V24, 230
RIC DIN
MAXMIN
Contactor20A
Contactor25A
Contactor40A
Contactor63A
AUX Block
2NO or 2NCor 1NO/1NC
4NO or 4NCor 2NO/2NC
4NO or 4NCor 2NO/2NC
2NO or 2NCor 1NO/1NC
AC/DC Istallation ContactorsNo noise!• All contacts doublemake/
doublebrake• Mechanical status display
Test voltage: 4kV/3Tamb. operation/storage:-20..+55/-30..+80°C
AuxilaryContactblock with2NO or 2NC or1NO+1NC contacts.For signalling andcontrol applicationsup to 6A with crowntwin contacts.For all RIC contactors.
Contactor 25AContactor with 4NO or 4NCor 2NO+2NC contacts.UC (AC/DC) versions arenoise free and do not needexternal freewheelingcircuits.No coil inrush overcurrent.Sealing cover optional.
Contactor 40AContactor with 4NO or 4NCor 2NO+2NC contacts.UC (AC/DC) versions arenoise free and do not needexternal freewheelingcircuits.No coil inrush overcurrent.Sealing cover optional.
Contactor 63AContactor with 4NO or2NO+2NC contacts.UC (AC/DC) versions arenoise free and do not needexternal freewheelingcircuits.No coil inrush overcurrent.Sealing cover optional.
Contactor 20AContactor with 2NO or 2NCor 1NO+1NC contacts.UC (AC/DC) versions arenoise free and do not needexternal freewheelingcircuits.No coil inrush overcurrent.Sealing cover optional.
Connection lay out (top/bottom)
Contact materialSwitching current ITHSwitching voltageSwitching power AC3Switching power AC1/AC7aOp Frequenz max. cycle/hrElectrical life cycles AC1
Coil voltage rangePower consumptionOperate / release time typ.
Data at Tamb =20°C
Ordering example
Installation contactorRIC25-400/UC230V
Aux blockRIC-AUX20
Sealing coverRIC-SEAL20
*OptionSealing coverType: RIC-SEAL20
RIC-SEAL25RIC-SEAL40-63
4NO or2NO/2NC
and others:www.comat.ch
NO NOISE!
Miniature Contactor
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice. 111 KAT
2008
Mon
itorin
g Re
lays
4
• Voltage Monitoring• Current Monitoring• Mains Monitoring• Isolation Monitoring• Thermo Protection Relay
Monitoring Relays
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.112 KAT
2008COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
Serie
s
Sock
et
Conta
ct
Page
Undervoltage Monitor MV52 DIN 35 6A 114
Undervoltage Monitor MV62 DIN 35 6A 114
Overvoltage and Undervoltage Monitor MV53 DIN 35 6A 115
DC Voltage Monitor CT524 6A 116
AC or DC Voltage Monitor CUEBU DIN 35 8A 117
Precision DC Voltage Monitor SSU2...(SSU11)
5A 118
RMS Precision AC/DC Voltage Monitor SSU7... 5A 118
Overvoltage Monitor EOCR-AR DIN 35 3A 120
Undervoltage Monitor EUCR-BR DIN 35 3A 120
Overvoltage and Undervoltage Monitor ECR-3D DIN 35 3A 120
Current Transformer SRCT-35 DIN 35 122
DC Current Monitor (200mA) CT512 6A 123
DC Current Monitor (2A) CT515 6A 123
DC Current Monitor (6A) CT516 6A 123
AC or DC Current Monitor CUEBI DIN 35 8A 124
Three-phase Monitor (50Hz) SSU33 6A 126
Three-phase Monitor (50Hz) SSU34 DIN 35 5A 127
Three-phase Monitor (60Hz) SSU36 DIN 35 5A 127
Phase-sequence Monitor SSU31 6A 128
Isolation Monitor ESU-D2 DIN 35 5A
5A
130
Motor Thermo Protection Relay TSR19 5A
5A
132
Monitoring Relays
Voltage Monitoring
Current Monitoring
Mains Monitoring
Isolation Monitoring
Thermo Protection Relay
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice. 113 KAT
2008
Mon
itorin
g Re
lays
4
Monitoring Relays
Voltage Monitoring
11DIN V V V
Comat products comply with different international standards and are certi-fied accordingly.
A detailed list can be found on our web page:
www.comat.ch
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.114 KAT
2008COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
60Hz
MV52 (50Hz)
MV62 (60Hz)
MV52 /AC230VMV52 /AC115V
MV62 /AC120V
6A 250VA1500VA/...180W30x106
0,7(–30%)UN...UN
5%0,1/0,5/1s
... UN +15%3,5VA,1W(–25)–10...+60°C
MV52 (50Hz), MV62 (60Hz)
50Hz
V
14
t
USET (V)
1112
VA
tsupply
gn
rdok al
V
failye
okgn
alarmrd
12 12
A2 A1
11 14
NL
okal
Zu s
chüt
zend
e An
lage
teile
Inst
alla
tion
à pr
otég
erIn
stal
latio
n to
be
prot
ecte
d
13mm
BS13-KBS13-G(incl.paper)
TS
35
90
134411
45
The MV52(50Hz) or MV62(60Hz) protects control systems,contactors and motors during undervoltage against thermaloverload and malfunctions.The monitoring can be set precisely in volts fromUN –30% up to UN.The switching off or on again follows delayed by 0,1/0,5 or1second.2 LEDs show the definite monitoring status.
Setting rangeHysteresist (fail -al-ok)
Switching current /voltageSwitch ratingMechanical switching cycles
Voltage tolerancePower consumptionAmbient temperature
Undervoltage Monitor
Order-Nr.
Data at Tamb. = 20°C
and otheres:www.comat.ch
AccessoriesLabel (5Piece) BS13-GLabel (5Piece) BS13-K
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice. 115 KAT
2008
Mon
itorin
g Re
lays
4
219V109V
207V103V
195V97V
0% 5% 10% 15% 20% 30% 35% 25%
184V92V
173V86V
161V80V
150V74V
230V115V
236V118V
241V121V
253V127V
258V129V
265V132V
270V135V
247V124V
+ 0% +2,5% +5% +7,5% +10% +12,5% +15% +17,5%
230V115V
al12
1411ok
al
ok
VNOM
VO1VO2
VU2VU1
HYST.
UNom + 2,5...17,5%UNom – 35...– 5%2,5%25ms...2,5sec70ms
6A 250VA1750VA/...170W2x107
UN –35%...+17,5%3,5VA,2W(–25)–10...+60°C
MV53
MV53/AC230VMV53/AC115V
MV53
V
50/60Hz
Vsu
pply
HYST.
tO tRtO tR
A2 A1
11 14
NL
okal
A2
12
Zu s
chüt
zend
e An
lage
teile
Inst
alla
tion
à pr
otég
erIn
stal
latio
n to
be
prot
ecte
d
failye
okgn
alarmrd
70
90
22,5
2
1
23
45678
9
10TS
35
Overvoltage and Undervoltage Monitor
The MV53(50/60Hz) protects single phase consumers in ACnetworks from over- and undervoltage.Overvoltage and undervoltage thresholds can be set indepen-dently in percentage of the nominal voltage using twoDIP-switches (see diagram above).Using a potentiometer allows setting an alarm delay of25ms...2,5s.A two-colored LED shows the definite monitoring status.
Setting range overvoltageSetting range undervoltageHysteresistO Alarm delaytR Reset time
Switching current /voltageSwitch ratingMechanical switching cycles
Voltage tolerancePower consumptionAmbient temperature
Order-Nr.
Data at Tamb. = 20°C
Never set both thresholds on 0%!
tO: Alarm delay
tR: Reset time
and otheres:www.comat.ch
Alarm threshold value
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.116 KAT
2008COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
≤10%
CT524
1110A2
6 1
10
2
2
12B1 A1
CT
9 8 7 5 3 4
R
V in
+
+DC24V
0-30V 40V
Umax
0,1/0,5/2s100ms
6A 250VA1500VA/...200W100 x106
0,8 -1,2UN
≤ 0,5W–25...+60°C
t
CT524
failye
okgn
alarmrd
supply
1
2
[V]
al
oktR tRt t fail
EXT
R
al
oktR tRt t fail
INT
R
al
oktR t fail
MIN
R
tRt
al
okfail
MAX
+
R
V
CT524.2/DC24V
Economy DC Voltage Monitoring Relaywith 3 twin changeover contacts.4 functions can be selected:Overvoltage/undervoltage monitoring with adjustablehysteresis or 2 range monitors (INT or EXT).Adjustable alarm delay.LED display for errors and ok.Contact inspection window at the top.Manual safety operation.
Alarm delay tReset time tR
Switching current /voltageSwitch ratingMechanical switching cycles
Voltage tolerancePower consumptionAmbient temperature
DC Voltage Monitor
Range
Order no. Accessories
Socket C12B0
Type No. = Module + Relay (FS-C, HF-32 incl.)
Data at Tamb. = 20°C
and otheres:www.comat.ch
Socket and Accessories: Page 97
Input resistance1210: 100k
RelayC32/DC24V
ModuleCT524/DC24V
TypeCT524.2/DC24V
SocketC12B0
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice. 117 KAT
2008
Mon
itorin
g Re
lays
4
50/60Hz
CUEBU15-700/AC230V
CUEBU
AC15...480V, DC15...700V5...50%1MxxxV/2% ±1digit
0,1...12s
8A 250V AC1 / ...240W2000VA / ...240W1x u, AgNi
AC230V +10%; -15% 50/60Hz
4,5VA/2,5W3kVrms /1min-20...+55°C /-40...+70°C
CUEBU15-700
AC230V 50/60HzPv 4VA
Input 5-9AC 15...480VDC 15...700VRi 1M
8A 250VA
V
t
[V]
Hys
alok
fail
R
t1
Up
MSupply
Up
Hys
alok
fail
R
t1
Lo
M
[V]
Supply
Lo
Supply
Hys
alok
fail
R
t1
Up
M
t1
[V]Lo
Up / Lo
failye
okgn
alarmrd
V V
1
2
5 9
4 6 10
LN
(+)U
Voltage Monitoring AC or DC
Monitoring Relayfor AC or DC voltages ranging fromAC15...480V, DC15...700V.LCD display for the measured value and the parameter setting.LED indication for the alarm status.Snap on to DIN-rail TS35 conform DIN (43880).
Monitoring rangeHysteresisInput resistance RiDisplay/Accuracy
Alarm delay time t1
Switching current /voltageSwitching power AC1Output contact
Operation voltage AC50/60HzPower consumption Pmax
IsolationTemperature: operating/storage
Data at Tamb. = 20°C
Functions
Order-Nr.
and otheres:www.comat.ch
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.118 KAT
2008COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
SSU11/...; SSU2x/...; SSU7x/...
al
USET
11
tfail tok
8
supp
ly
9
USET
USET
USET
supp
ly
3s:
+LE
Ds normal
fail
delay
alarm
FAILOK
OKFAIL
ok
meas.ye
okgn
alarmrd
9 2 3 4 5 6 0 - 210mV 0 - 38V 0 - 38V 0 - 77V 0 - 157V 0 - 285V
0,1 - 200mV 0,1 - 35V 0,1 - 10V 10 - 75V 40 - 150V 0*/50 - 270V0,5mV 20mV 20mV 100mV 100mV 0,5V
0,1s - 600s
UC110-240VU UC60-127VU UC24-48VU UC12-15VU-20% +10% -20% +26% -20% +55% -25% +33%
+10...+50°C (-25...+60°C)
1 x co 5A, 250V; 1 x no Transistor NPN, DC50mA, 24V
SSU2x/UC...V
SSU7x/UC...V
F
V V SSU11 /...SSU2x /...SSU7x /...
35mm
79 8 5 3
11 610 1 2
4
L +
N
DC
10-3
2V
50m
A
Um
+
+( )
( )
RL
SSU DC 0-38V/UC24-48V: SSU23/UC24-48VSSU RMS AC/DC 0-200mV/UC110-240V: SSU79/UC110-240V
SSU11/UC110-240V SSU26/UC110-240VSSU11/UC60-127V SSU25/UC60-127VSSU11/UC24-48V SSU24/UC24-48VSSU11/UC12-15V SSU23/UC12-15V
SSU12/...V SSU22/...VSSU13/...V SSU23/...VSSU14/...V SSU24/...VSSU16/...V SSU26/...V
*SSU76
Precision DC/RMS Voltage Monitoring Relay
The SSS11, SSU2x and SSU7x are high precision voltage monito-ring relays for DC or RMS AC/DC with interactive front operationand display of values and voltmeter function. Two values for FAILand OK can be programmed. With this, the hysteresis is automati-cally given. Depending of the programmed values the over- orundervoltage monitoring function is defined. Fixed max. and min.values are given for alarm triggering. However, the min. value mo-nitoring can be disabled. The measuring input is galvanically iso-lated from the power supply (2-10). High EMC immunity designand self diagnostic features guarantee very high reliability and along service life. Applications are for example monitoring of batteryvoltage in industrial installations.
Switching current /voltage
Measurement range (x)Measurment rangeAdjustment rangeResolutiont fail, t ok
Power supplyPower supply toleranceAmbient temp
AccessoriesSocket: C11-ARetaining clip: HF-24Frontpanel mounting: FZ-23
Example of order
Selection of type TypeFor DC measurement
For RMS AC/DC
Attention:P/O numbers of several devices were changed (refer below). Devices are identical.
and otheres:www.comat.ch
Socket and Accessories: Page 97
Old number: Replaced by: Old number: Replaced by:
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice. 119 KAT
2008
Mon
itorin
g Re
lays
4
Monitoring Relays
Current Monitoring
11DIN A A
Comat products comply with different international standards and are certi-fied accordingly.
A detailed list can be found on our web page:
www.comat.ch
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.120 KAT
2008COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
54
1010
2416
20
62
A2 A1 15 16 18
EOCR-AR
EUCR-BR
[A] 1x 2x 3x 4x 5x
-05 0,5-6 0,25-3 0,17-2 0,13-1,5 0,1-1,2
-30 2,5-30 1,25-15 0,83-10 0,62-7,5 0,5-6
-60 5-60 2,5-30 1,7-20 1,25-15 1-12
SCHÜTZ
CONTACTORLN
al
LOAD1
22
1
(+) UB
failye
okgn
alarmrd
A
16
supply
18
tO tO tR
15okal
1/2
A
A
EUCR-BR-... / UC24V
50/60Hz
0,3 - 30s0,5 - 150s
3A 250VA750VA/...90W20x106
0,8-1,1/1,25 UN
3(5)VA /1W–20...+60°C
EOCR-AR- ... / AC230VEOCR-AR- ... / AC115V
EOCR-AR / EUCR-BR
05 30 60
AC UC
EOCR-AR- ... / UC24V05 30 60
t
EUCR-BR- ... / AC230VEUCR-BR- ... / AC115V
-05-30-60
EOCR-AR
EUCR-BR
(AC/DC)
1 fail or 2 fail = FAIL
21
1
2
L+N
15A2okal+
A1 16 18
Current Monitoring Relays
The EOCR-AR and the EUCR-BR monitor overcurrent and undercurrenton AC power circuits.One or two current paths can be monitored directly up to 60(75)A,by means of the integrated current loop transformers.The adjustable alarm delay (tO) and the automatic alarm resetting(tR) permit universal usage in motor and transformer protectionsystems, monitoring of electrical heating elements and in the controlof pumps, ventilation systems, suction and feed devices.The nominal monitoring range in the 3 types -05/-30/-60 can bealtered by multiple looping of the conductor (see schedule above).
Alarm delay tO
Reset time tR
Switching current /voltageSwitch ratingMechanical switching cycles
Voltage tolerance AC/UCPower consumptionAmbient temperature
Order-Nr.
Over current relay
Under current relay
Data at Tamb. = 20°C
and otheres:www.comat.ch
JUST LOOP ITSetting ranges
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice. 121 KAT
2008
Mon
itorin
g Re
lays
4
A
[A] 1x 2x 3x 4x 5x
-05 0,5-6,5 0,25-3,2 0,17-2,1 0,13-1,63 0,1-1,3
-60 5-75 2,5-38 1,7-25 1,25-18,8 1-15
LN
(+)UB
L1 L2 L3
failye
okgn
alarmrd
ECR-3D-... / UC110-240VECR-3D-... / UC24V
ECR-3D
05 60
UC
-05-60
ECR-3D
(AC/DC)
0,3 - 30s1,0 - 120s /
3A 250VA750VA/...90W20x106
0,8-1,1/1,25 UN
3(5)VA /1,5W–20...+60°C
t
71 70
1010
3016
21
10
55
1826 25 28 16 15A1A2
1 fail or 2 fail or 3 fail = FAIL
(L1)
1
2
3
21
(L2) (L3)
A
16
supply
18
tO
15
A
tO
2628
25
Phasesequenceerror
L1+L2+L3off
L1 or L2 or L3
R1
R2
0
0
U
tR tR
L+N
26A2okal+
A1 25 28 16 15 18
R2 R1
okal
The ECR-3D is for monitoring overcurrent and undercurrent on ACpower circuits.Three current paths of up to 60(75)A can be monitored directlyby means of the inte-grated current loop transformers.The adjustable alarm delay (tO) and the automatic alarm resetting(tR) permit universal usage in automation and protection techniques.The set values are displayed automatically by setting the respectiveparameters.Triggered faults remain stored and displayed until reset.
Alarm delay tO
Reset time tR
Switching current /voltageSwitch ratingMechanical switching cycles
Voltage tolerance AC/UCPower consumptionAmbient temperature
Current Monitoring Relays
Order-Nr.
Current monitoring relays
Data at Tamb. = 20°C
and otheres:www.comat.ch
Setting ranges
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.122 KAT
2008COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
50
386
4,5
10
SRCT-35-... / 5A
SRCT-35
50 100
- 50/5A- 100/5A- 250/5A- 500/5A
SRCT-35
250 500
2,5VAClass 150/60Hz
720Vx 1,5 (Class 1,5)–5...+40°C
65
40
FORM4
BEF 1
76 2
ø4.3
38
35
Kk
1)
UC (AC/DC)
Current Transformers
Current transformers of the SRCT-35 series transform highAC currents into proportional secondary current in the ratio10:1 (type -50) up to 100:1 (type -500).With accuracy class 1, coupled with a large power reserve(PN: 2,5VA) and high overload capacity up to 150%, theSRCT-35 is the ideal transformer for general applications andfor the use with Comat monitoring relays ..AR, ..BR, ..3D.
PowerAccuracyFrequence range
Operating voltageOverloadAmbient temperature
Direct mounting Order-Nr.
1) Other primary currents on request
and otheres:www.comat.ch
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice. 123 KAT
2008
Mon
itorin
g Re
lays
4
0,1/0,5/2s100ms
6A 250VA1500VA/...200W100 x106
0,8 -1,2UN
≤ 0,5W–25...+60°C
CT512.2/DC24VCT515.2/DC24VCT516.2/DC24V
CT512,515,516
≤10%max
0-200mA 300mA0-2A 3A0-6A 7A
t
RL
1110A2
6 1
10
2
2
12B1 A1
CT
9 8 7 5 3 4
R
+DC24V
in
CT512 (200mA)
CT515 (2A)
CT516 (6A)
failye
okgn
alarmrd
supply
1
2
[A]
al
oktR tRt t fail
EXT
R
al
oktR tRt t fail
INT
R
al
oktR t fail
MIN
R
tRt
al
okfail
MAX
+
R
A DC Current Monitor
Economy DC Current Monitoring Relaywith 3 twin changeover contacts.Without external shunt up to 6A.4 functions can be selected:- Overcurrent /undercurrent monitoring with adjustable hysteresis
or 2 range monitors (INT or EXT).- Adjustable alarm delay.- LED display for error and ok.Contact inspection window at the top.Manual safety operation.
Alarm delay tReset time tR
Switching current /voltageSwitch ratingMechanical switching cycles
Voltage tolerancePower consumptionAmbient temperature
Order no. Accessories
RangeSocket C12B0
Type No. = Module + Relay (FS-C, HF-32 incl.)
Data at Tamb. = 20°C
and otheres:www.comat.ch
Socket and Accessories: Page 97
RelayC32/DC24V
ModuleCT512/DC24V
TypeCT512.2/DC24V
SocketC12B0
Voltage drop (2-12)CT512 : ≤ 300mVCT515 : ≤ 200mVCT516 : ≤ 100mV
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.124 KAT
2008COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
CUEBI
AC/DC 0,1...10A5...50%5mxx,xA/2% ±1digit
0,1...12s0,1...20s
8A 250V AC12000VA / ...240W1x u, AgNi
AC230V +10%; -15% 50/60Hz
4,5VA/2,5W3kVrms /1min-20...+55°C /-40...+70°C
CUEBI01-10
AC230V 50/60HzPv 4VA
Input 5-9AC 0,1A...10ADC 0,1A...10AImax.15ARi 5m
8A 250VA
A
t
failye
okgn
alarmrd
[A]
Hys
alok
fail
R
t1
Up
MSupply
t2Up
Hys
alok
fail
R
t1
Lo
M
[A]
t2
Supply
Lo
Supply
Hys
alok
fail
R
t1
Up
M
t1
[A]
t2
Lo
Up / Lo
CUEBI01-10/AC230V
50/60Hz
A A
1
2
5 9
4 6 10
LN
(+)U
Current Monitoring AC or DC
Monitoring Relayfor AC or DC currents ranging from 0,1A up to 10A withstart-up delay.LCD display for the measured value and the parameter setting.LED indication for the alarm status.Snap on to DIN-rail TS35 conform DIN (43880).
Monitoring rangeHysteresisInput resistance RiDisplay/Accuracy
Alarm delay time t1Start-up delay t2
Switching current /voltageSwitching power AC1Output contact
Operation voltage AC50/60HzPower consumption Pmax
IsolationTemperature: operating / storage
Functions
Order-Nr.
Data at Tamb. = 20°C
and otheres:www.comat.ch
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice. 125 KAT
2008
Mon
itorin
g Re
lays
4
Monitoring Relays
Mains Monitoring
11DIN 3 3
Comat products comply with different international standards and are certi-fied accordingly.
A detailed list can be found on our web page:
www.comat.ch
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.126 KAT
2008COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
SSU33L
>275V—
<160V—
20 - 100V35 - 173V3-15°/3-15Hz
—>480V
—<280V
20 - 100V35 - 173V3-15°/3-15Hz
SSU33L/AC230V SSU33L/AC400V
SSU33 (50Hz)
C11A
75
38
3
1) 230V ( ) 2) 400V ( )
1)10
< >
t del
SSU33L
failred
FIX
2
9
11
2)
∆ U, ϕ, ƒ
L3L1 L2 N
MAXMINU
7 4 5gn
alok
alarmok
PHASESEQUENCE
0,2-5s
µ 6
A 25
0VA
1500
VA/.
..270
W
2
1
L1
L2L3
NL1
L2L3
3x230(400)V 3x400V1) 2)
∆
UU
UU
∆U∆U∆ϕ /ƒ
1
2
U
Three-phase Monitoring Relay
The SSU33(50Hz) provides comprehensive monitoring of three-phase mainssupplies with or without neutral.The following mains faults are monitored:Error signal 1 U (V , V ):Exceeding or dropping below the fixed voltage values Umin/Umax for L1-N orL1-L2 (no differential voltage, phase position or frequency fault).Error signal 2 ∆U, ∆ϕ, ∆ƒ:One or more of the three voltages, phase positions, phase sequence or the mainsfrequency are diverging from the required value.Depending on the nature of their occurrence ∆-errors are evaluated cumulatively.Any error is signalled by the red LED and is reported after expiry of the set alarm-delay time (tdel 0,2...5s) via 7-4-5.In the correct status (ok) the green LED is illuminated (4-5 open, 4-7 closed).
Overvoltage>(Umax)
Undervoltage<(Umin)
Differentialrange
AccessoriesSocket C11ARetaining clip HF-24Front mounting FZ-23
Order no.
and otheres:www.comat.ch
Socket and Accessories: Page 97
In case of a power failure the alarm is activated withoutdelay !
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice. 127 KAT
2008
Mon
itorin
g Re
lays
4
105 5
SSU34, SSU36
75
U
∆
UU
UU
∆U∆U∆ϕ /ƒ
SSU34 (50Hz)
SSU36 (60Hz)3
1
2
µ 5
A 25
0VA
1250
VA/.
..150
W
∆ U, ϕ, ƒ
MAXMINU
fail
< >
t del
SSU34/36
3
L3
L1L2
N
L
4 5 6 7 8
gn
alok
alarmok
PHASESEQUENCE
red
0,2-5s
1
2
oderor
3
50Hz 50Hz 50Hz58/100VA 230/400VA 290/500VA
60-70V 235-275V 300-350V105-121V 410-480V 520-600V
40-55V 160-225V 200-280V70-95V 280-390V 350-485V
5-25V 20-100V 20-100V10-50V 35-173V 35-173V3-15°/3-15Hz 3-15°/3-15Hz 3-15°/3-15Hz
SSU34/AC100V SSU34 /AC400V SSU34/AC 500V
60Hz 60Hz 60Hz120/208VA 265/460VA 277/480VA
125-145V 270-320V 284-232V216-250V 470-550V 490-575V
85-115V 185-260V 194-270V148-200V 322-450V 336-470V
10-50V 20-100V 20-100V17-87V 35-173V 35-173V5-24°/3-22Hz 4-21°/ 3-19Hz 4-21°/ 3-19Hz
SSU36/AC208V SSU36 /AC 460V SSU36 /AC480 V
50
E The SSU34(50Hz) and the SSU36(60Hz) provide comprehensive monitoring ofthree-phase mains supplies with or without neutral.The following mains faults are moni-tored:Error signal 1 U (V , V ):Exceeding or dropping below the set voltage values Umin/Umax for L1-N orL1-L3,L (no differential voltage, phase position or frequency fault).Error signal 2 ∆U, ∆ϕ, ∆ƒ:One or more of the three voltages, phase positions, or the mains frequency are di-verging from the required value. Depending on the nature of their occurrence ∆-errors are evaluated cumulatively.Error signal 3 :Connection polarity reversal (wrong phase-sequence). Any error is signalled bythe red LED "fail" and is reported after expiry of the set alarm-delay time (tdel0,2...5s) (for error signal 3 undelayed) via 5-6 and 7-8.In the correct status (ok) the green LED is illuminated (5-6 and 7-8 open, 5-4and 7-2 closed).
Three-phase Monitoring Relay
Overvoltage>(Umax)
Undervoltage<(Umin)
Differentialrange
Order no.
Detachable Terminals
and otheres:www.comat.ch
DO NOT connect simultaneously: neutral conductor N and bridge L3-L !
In case of power failure the alarm is activated without delay !
MAINS MONITORING
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.128 KAT
2008COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
...1,2 . UN
UN –20%3% / UN
10VA / ≤ 1,5W
6A 250VA1500VA/...200W30x106
SSU31/AC400VSSU31/AC208V
SSU31
50/60Hz
79 8 5 3
11 610 1 2
4
L1L2L3
ok al
SSU31
L1L2L3
200ms 50ms
U
74
5gn
rdok
supply
al
3
failye
okgn
alarmrd
Phase-sequence Monitoring Relay
The SSU31 serves as a phase-sequence, three-phase undervoltageand phase failure monitor.The monitoring function helps to ensure the correct rotationdirection of pumps, motors and conveyors in mobile devices withconnection to different power outlets.The defined undervoltage and phase failure protects againstmalfunction and damage caused by overheating.
SupplyCut-off undervoltageHysteresisPower consumption
Switching current /voltageSwitch rating AC1/DC1Mechanical switching cycles
Order no. Accessories
Relay socket C11ARetaining clip HF-24Front mounting FZ-23
Data at Tamb. = 20°C
and otheres:www.comat.ch
Socket and Accessories: Page 97
Failure of L2 or L3 cannot be displayed (LED)!
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice. 129 KAT
2008
Mon
itorin
g Re
lays
4
Monitoring Relays
Isolation Monitoring
DIN
Comat products comply with different international standards and are certi-fied accordingly.
A detailed list can be found on our web page:
www.comat.ch
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.130 KAT
2008COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
meas.ye
okgn
alarmrd
1k...50k / 0...52VDC≤10%4-30k / 4k fix≤800ms / 30k0,1-10sAC250V
5A 250VA1250VA/...150W5x106
UN ±15% / UN ±20%2W(–25)0...50(60)°C
UC (AC/DC)
ESU-D2
ESU-D2/UC110-240VESU-D2/UC24-48V
al30k
Scale4k
RMAX
(AL2) RMIN
(AL1) RSET
4k(Fix)
30k
1618
15
25
AL1
AL2
tdeltRtRtdel
(38)2826
okgn
ye
ok
supp
ly
ESU-D2
Outputcontacts
LEDs
(37)
Trend+
al rd
1s 1s
ESU-D2
105 5
75
50
meas.ye
okgn
alarmrd
1k...50k / 0...52VDC≤10%4-30k / 4k fix≤800ms / 30k0,1-10sAC250V
5A 250VA1250VA/...150W5x106
UN ±15% / UN ±20%2W(–25)0...50(60)°C
UC (AC/DC)
ESU-D2
ESU-D2/UC110-240VESU-D2/UC24-48V
al30k
Scale4k
RMAX
(AL2) RMIN
(AL1) RSET
4k(Fix)
30k
1618
15
25
AL1
AL2
tdeltRtRtdel
(38)2826
okgn
ye
ok
supp
ly
ESU-D2
Outputcontacts
LEDs
(37)
Trend+
al rd
1s 1s
ESU-D2
E2
E1N 25L
LN
(+)
UB
26 28 37 38
AL1
AL2
15 16 18+ +
V
AL1ESU-D2
AL2
Zu überwachende AnlageInstallation à surveiller
Installation to be monitored+DC 0..52V
Pre alarm
Main alarm
0,1V/k
(1mA 12V) 5A 250VA
E0,1V/k
5V
105 5
75
50
Isolation Monitor
The ESU-D2 monitors the isolation resistance in non-groundedDC-networks (24-48VD).Two alarm steps (prealarm AL1 and main alarm AL2) areindicated via separate output contacts.Settable alarm delay (tdel): 0,1-10sec.Displays: bargraph-display of the measured earthing resistance4...30k (green = ok). Two red LEDs show the groundtendency towards plus (+) or minus ( ).Measuring terminal 5V for the external display of the earthingresistance (0,1V/k ).Test functions: Periodic automatic check, also with key “Test”.Environmental failures: monitoring of AC-short circuit,overvoltage, ground interruption.
Measuring rangeError of measurementSetting range AL1/AL2Time of error-detectionAlarm delay time settable
Voltage stability + or– /earth
Switching current /voltageSwitch ratingMechanical switching cycles
Voltage tolerance AC/UCPower consumptionAmbient temperature
Order no.
Detachable Terminals
Data at Tamb. = 20°C
and otheres:www.comat.ch
Connect E1, E2 separately on E.
Only one ESU-D2 per DC network !
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice. 131 KAT
2008
Mon
itorin
g Re
lays
4
Monitoring Relays
Thermo Protection Relays
11 CM
Comat products comply with different international standards and are certi-fied accordingly.
A detailed list can be found on our web page:
www.comat.ch
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.132 KAT
2008COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
50/60Hz
100..1800 ; 0..180020Rfail >220015V / Rsens ∞≤3mA
5A 250VA1250VA/...180W30x106
–15/+10%≤5VA–25...+60°C
TSR19/AC230VTSR19/AC115V
TSR19
TSR19CM
75
38C11A
failye
okgn
alarmrd
UC(AC/DC)
TSR19/UC24-48V
1 2
11-9
°C/F
1-3
2,5s
RPTC/ -SWITCH
supply RESET
gn
rdok al
fail
79 8 5 3
11 6A210 1
A12
4
okal
+
ThermoSwitch
2
1 PTCSensor
Thermo Protection Relay
The TSR19 is intended to monitor the temperature of motor coils,generators and transfomers.It detects the temperature of the windings over the change inresistance of the PTC thermistors 1 or the position of the thermoswitches 2 . The circuit is designed to detect a break in the conti-nuity of the detection circuit and ground failures.On position “PTC”, line or sensor fault is also detected.Reset after failure detection: Press reset button or interrupt supplyvoltage for >200ms.
Sensor resistance Rok
Sensor wire Rmax
Error-detection Rfail
Sensor supply U5-7
Sensor supply 5max
Switching current /voltageSwitch ratingMechanical switching cycles
Voltage tolerancePower consumptionAmbient temperature
Accessories
Socket C11ARetaining clip HF-24Frontpanel mounting: HF-23
The TSR19 replaces the types TSR17 and TSR18.
Order no.
Data at Tamb. = 20°C
and otheres:www.comat.ch
Socket and Accessories: Page 97
or
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice. 133 KAT
2008
SMS
Rela
y / C
omat
Box
X
5
SMS Relay / Comat BoxX
• SMS Relay• Miniature Controller, Comat BoxX
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.134 KAT
2008COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
Notes
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice. 135 KAT
2008
SMS
Rela
y / C
omat
Box
X
5
• Monitoring of all inputs and outputs with SMS messaging• Remote control of outputs by SMS• Sequential alert messaging to 5 different subscribers• Easy confi guration with PC and «FAST SMS SET»-up confi guration software• Power failure notifi cation by SMS messaging• Status change messages by SMS• User defi ned message text
Automation Products
SMS Relays
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.136 KAT
2008COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
ApplicationsSMS Relay
CMS-10
Monitoring Alerting, ControllingAlerting Controlling MonitoringControlling Monitoring Alerting
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice. 137 KAT
2008
SMS
Rela
y / C
omat
Box
X
5
Confi guration software
Technical Data’s
Dimensions
Ante
nne
SMS RelayCMS-10
Operating voltage AC 110-240VA 50/60Hz DC 12-48VD max. 10%
Power consumption 8VA /6W 6W
Switching capacity 4x 10A 250V
Temperature range Tu: -25...+55° CRel. humidity: 5 ...95% (non condensing)Protection IP20
Inputs 6x digital trigger level 85Va 6x digital trigger level 9,5Vd
Outputs 4x CO contacts
Provider (Phone/Network) User selectable (dependent on SIM card)
Installation according to DIN 43 880
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.138 KAT
2008COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
Installation note
SMS RelayCMS-10
Order-Nr.
Type Description
CMS-10/AC110-240V SMS Relay AC 110-240V Base unit only with small antenna (CMS-ANT)
CMS-10/DC12-48V SMS Relay DC 12-48V Base unit only with small antenna (CMS-ANT)
KIT consisting of: A base unit with small antenna, antenna with magnetic pod and 2.5m cable, programming cable, USB-RS232 Interface connector, CD with «FAST SMS SET»-up programming software and operation manual
CMS-10KIT/AC110-240V Installation kit complete (SMS Relay AC110-240V)
CMS-10KIT/DC12-48V Installation kit complete (SMS Relay DC12-48V)
Accessories
CMS-RS232 SMS Relay Programming Cable RS232
CMS-USB USB-RS232 Interface connector (including driver CD)
CMS-ANT Small spare antenna for base unit, 63mm long
CMS-ANT-MAG/2.5M Antenna with magnetic pod and 2.5m antenna cable
CMS-ANT-SPEZ /5M External antenna with 5m antenna cable
CMS-ANT-KAB/5M Antenna cable 5m (extension)
CMS-ANT-KAB/10M Antenna cable 10m (extension)
CMS-ANT-ADAPT Adaptor FME to SMA plug
CMS-CAP Device cover (spare)
CMS-CD CD with FAST SMS SET -up programming software and manual
The Base unit device is delivered fully operational and includes the small aerial CMS-ANT.
Before installation, the fi nal location of installation must be taken into consideration.
For installation inside a control panel, the small device aerial may not be suitable and needs to be replaced by the antenna with magnetic pod (CMS-ANT-MAG/2.5M) or by the external antenna (CMS-ANT-SPEZ/5M).
These two antennae provide considerably better results and improve communication with the mobile network.
Please ask our product specialists if you require any support.
Antenna with magnetic pod and 2.5m antenna cable.
Type: CMS-ANT-MAG/2.5M
External antenna with 5m antenna cable
Type: CMS-ANT-SPEZ/5M
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice. 139 KAT
2008
SMS
Rela
y / C
omat
Box
X
5
• Programming via PC• Remote controlling and voice message over telephone network or Cellular phone• Remote maintenance and remote operation of the installation• Comprehensive function block library• Password protected
BoxX
LCDDISPLAY UNIT
OK
ESC
Q REL 8A250V1 2 3 4
TYPE:AF-10MR-D-..... /DC24VD
DC 24VD DC 24VD or 0-10V1 2 3 4 5 6+ +
BoxXPOW
REC
MIC
VOL
+
AF-MUL/DC12-24VDVOICE & REMOTE UNIT
EXT SPK WAVPC1 42 3
DC12-24VD +
PC
NET
PC
Automation Product
The speaking controller
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.140 KAT
2008COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
BoxX
CAPCOVER
TYPE:AF-10MT-GD-..... /DC24VD
Q PNP 2A24VD1 2 3 4+ + + +
DC 24VD DC 24VD or 0-10V1 2 3 4 5 6+ +
ESC
OK
BoxX
LCDDISPLAY UNIT
L NAC110-240VA
N 1 2 3 4 5 6
TYPE:AF-10MR-A-..... /AC110-240VA
Q REL 8A250V1 2 3 4
PC
127BoxX
BoxX
AF-MUL/AC110-240VAVOICE & REMOTE UNIT
POW
REC
MIC
VOL
+
AC110-240VA LN
EXT SPK WAVPC1 42 3
NET
PC
6 / 12 Inputsdigital / analog
4 / 8 OutputsRelay / Transistor
The Controller • Program storage 64kByte• Time range 0,01s-99,99h• Counting values 1-999’999• System timer back up 100h
Function blocksIntermediate relaysTimer instructions(up to the year 2099)
Voice moduleAF-MUL for98 messages(total max 8min)
active
Type “LCD”Type “CAP”
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice. 141 KAT
2008
SMS
Rela
y / C
omat
Box
X
5
BoxX
°C
0
0
0
0
0
0
0
05
4
3
2
1
0
1
2
ESC
OK
BoxX
LCDDISPLAY UNIT
The programming software QUICK IIallows easy and transparent pro-gramming of the Comat BoxX witha PC.QUICK II is based on Windows®.127 function blocks can be storedinside the program memory of theComat BoxX.Stored programs cannot be losteven during a power loss.Therefore back up batteries are notneeded.With the simulation tool, the set upcan be tested on the PC beforecommissioning.Example: Page 4
The Comat BoxX can be program-med by PC or with the snap-on LCDdisplay with integrated functionkeys.It is possible to modify time intervalsof the function blocks in the existingcontrol program on site directly onto the installation.The LCD display can be connectedto the Comat BoxX to visualizeconditions or may be removed(without voltage) and used onanother Comat BoxX.
The 24V versions of the Comat BoxXcan also process analogue signals0...10V with increments of 0.1V .All inputs can be used or configuredat random as analogue or digitalinputs.Function blocks for the comparisonof analogue values are available,i.e. to monitor temperature in aheating system.
Programming thefunction blocks
Programming software
Analogueinputs
Control tasks can be solved easilywith the function blocks available inthe library.Programming codes in a high-levelprogram language are not required.Simply place the correspondingfunction blocks and link them withother function blocks according tothe required control function.
The Application
Setting the display
The voice andremote module
The voice module allows the playingof messages through either thebuilt-in or external loud speakers.The voice module also replaysphone calls or dials phone numbersto send emergency or statusmessages.Messages are recorded directly overthe built-in microphone or aretransferred as *.wav files directlyfrom the PC.
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.142 KAT
2008COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
BoxX
Example: Programing environment
Programming software Quick II
COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice. 143 KAT
2008
SMS
Rela
y / C
omat
Box
X
5
BoxX
Incl. AF-BCAF-ATL
BoxX
AF-BC
PC
AF-MUL
AF-AUD
AF-ATL
AF-R
S23
2
EXT SPK WAVPC
Incl. AF-BCAF-ATL
BoxX
AF-BC
PC
AF-MUL
AF-R
S23
2
NET
PC
AF-D
232
Each Comat BoxX can be controlledvia a telephone line if connected tothe extension module AF-MUL(voice & remote unit).The AF-MUL will answer calls andallows access after the password isaccepted.The Comat BoxX with the AF-MUL isable to broadcast up to 98 prede-finded conditions, for examplealarms, over the phone network.The designated phone number isdialled and the recorded message isplayed over the telephone.The message can also be broad-cast over auxiliary loudspeakers.
Programming via the MULvoice and remote unitThe Extension
module
Recording of messageswith the PC
Messages are transferred to thevoice module as *.wav files directlyfrom the PC over the AF-AUD cable.
Programming simulation andmonitoring with the PC.
This edition replaces all previous issues. Availability, errors and specifi cation subject to change without notice.144 KAT
2008COMAT AG • BERNSTRASSE 4 • CH-3076 WORB • SCHWEIZ www.comat.chTel. +41 (0)31 838 55 77 • Fax. +41 (0)31 838 55 99 • [email protected]
BoxX
PNP2A 24VD Q1 Q2 Q4
+ + +
AF-10MR-D-...
Q1 Q4
+
L N 1 2 6N
AF-10MR-A-...
Q1 Q2 Q4
UB
AF-20MR-D-...
Q1 Q2 Q8
12
AF-20MR-A-...
Q1 Q2 Q8
Q1+ +
Q8
+
BUS
BUS
BUS
BUS
AC110-240V AC110-240VA
AF-10 MR-D-CAP/DC 24 VAF-10 MR-D-LCD/DC 24 V
AF-10 MT-GD-CAP/DC 24 VAF-10 MT-GD-LCD/DC 24 V
1 2
L N N
AF-20MR-A-CAP/AC 110-240 VAF-20MR-A-LCD/AC 110-240 V
AF-20MR-D-CAP/DC 24 VAF-20MR-D-LCD/DC 24 V
AF-20MT-GD-CAP/DC 24 VAF-20MT-GD-LCD/DC 24 V
+
DC 24VD
+
DC 24VD or 0-10V
121 2
INPUT
OUTPUT
RELAY8A 250V
RELAY8A 250V
PNP2A 24VD
RELAY8A 250V
RELAY8A 250V
6x
4xOUTPUT
12x
8x
OUTPUT
4x
INPUT
OUTPUT
8x
50/60Hz
INPUT
6x 6
Q2
OUTPUT
4x
Q2
OUTPUT
8x+
12x
AF-10 MR-A-CAP/AC 110-240 VAF-10 MR-A-LCD/AC 110-240 V
AF-10 AF-20 AF-MUL
AC110-240VA 50/60Hz
DC24VD max.10%
3VA/1,5W 5VA/1,5W
8A 250VA 2A 24VD
UB UB
AC110-240V AC110-240VA
INPUT50/60Hz
1 2UB
DC 24VD DC 24VD or 0-10V
0,8VA
BoxX BoxX
BoxX BoxX
AF-MUL / AC110-240 V
AF-BC
AF-RS232
AF-MUL / DC12-24 V
AF-D232
AF-LCD
AF-CAP
AF-CDR1
CMS-USB
AF-MOD
AF-M232
AF-AUD
AF-ATL
AC110-240VA
DC12-24VD
6 INPUTS
4 OUTPUTSThe Types12 INPUTS
8 OUTPUTS
6/12 InputsdigitalAC110-240V
4/8 Ouputsrelays8A 250VA
Order no. without displaywith display
without displaywith display
without displaywith display
without displaywith displayOrder no.
6/12 Inputsconfigurable:digital / analog0-10V (0,1V)
4/8 Outputsrelays8A 250VA
without displaywith display
without displaywith displayOrder no.
4/8 Transistoroutputs PNP2A 24VD
Accessories
Voice and remote unit 1)
Modem Interface connector
Programming cable
AF-MUL Programming cable
AF-5MUL Audio Cable 2)
Audio Cable
Display with function keys
Cover (instead of AF-LCD)
AF-MUL Bridge connector 2)
Order no. Order no.
1) Inclusive AF-BC and AF-ATL2) Included with AF-MUL
Tu without display-25...+55°C
Tu with display0...+55°C
Rel. humidity: 5...95%(non condensing)
ProtectionIP20
Ambience conditions
The Data
Switching power
Power consumption
Operating voltage UB
Modem
CD-ROM
Voice and remote unit 1)
Converter USB-RS 232
Comat worldwide
AUSTRALIAOHMIC CONTROLS PTY LTD.www.ohmic.com.au
AUSTRIAELTAX GMBHwww.eltax.at
INTERMADOX GMBHwww.intermadox.at
BELARUSFEK COMPANYwww.turck.by
BELGIUMMULTIPROX N.V.www.multiprox.be
BULGARIASENSOMAT GMBHwww.sensomat.info
CANADACHARTWELL ELECTRONICS INC.www.chartwell.ca
CHINA P.R.ELCO (TIANJIN) ELECTRONICS CO. LTDwww.elco-holding.com
CROATIAVARGA ELEKTRONIK D.O.O.www.varga-elektronik.hr
TIPTEH D.O.O.www.tipteh.si
CZECH REPUBLICTURCK S.R.O.www.turck.cz
DENMARKHANS FÖLSGAARD ASwww.hf.net
EGYPTE.T.E. EGYPTIAN TRADING AND ENGINEERING [email protected]
ESTONIAOSAUHING «SYSTEM TEST»www.systemtest.ee
FINLANDKY VARESTE KBwww.vareste.fi
OEM FINLAND OYwww.oem.fi
FRANCETURCK BANNER S.A.S.www.turckbanner.fr
GERMANYCOMAT SAM STEUERUNGSTECHNIKwww.comat-online.dewww.releco-online.de
KÜHN CONTROLS S.L.www.multicomat.dewww.releco-comat.de
GREAT BRITAINCAMIS COMPONENTSwww.camiscomponents.com
GREECEVASSILIS GETSOS (MEGA EL)[email protected]
HUNGARYTURCK HUNGARY KFT.www.turck.hu
INDIACONCORD AUTOMATION & CONTROLSwww.cacindia.net
INDONESIAPT.YABESTINDO MITRA UTAMA [email protected]
IRELANDCAMIS COMPONENTSwww.camiscomponents.com
ITALYS.P.I.I. SOCIETÀ PER AZIONIwww.spii.it
KOREASAMWHA ENGINEERING CO. LTD.Korea Seoulwww.samwha.co.kr
LITHUANIAHIDROTEKAwww.hidroteka.lt
MALAYSIAELECTRICAL MARKETING SDN. BHD.www.elemar.com.my
MAROCCOCENELEC [email protected]
NETHERLANDSVIERPOOL B.V.www.vierpool.nl
NORWAYDANYKO A.S.www.danyko.no
PHILIPPINESMANUEL H.M. MANUEL ENTERPRISESwww.hmmanuel.com.ph
POLANDANIM EXPORTwww.anim.com.pl
PORTUGALSALMON & CIA. LDA.www.salmon.pt
ROMANIASYSCOM 18 S.R.L.www.syscom.ro
TURCK BRANCH OFFICE ROMANIAwww.turck.ro
RUSSIASENSORLINKwww.sensorlink.ru
SINGAPOREMECOMB SINGAPORE LIMITEDwww.mecomb.com.sg
SLOVAKIAMARPEX S.R.O.www.marpex.sk
SLOVENIATIPTEH D.O.O.www.tipteh.si
SOUTH AFRICARET AUTOMATIONwww.retautomation.co.za
SPAINRELECO S.A.www.releco.com
SWEDENBEVING ELEKTRONIK ABwww.bevingelektronik.se
TAIWANE-SENSORS & AUTOMATION INT’L CORP.www.e-sensors.com.tw
THAILANDSRINUTCH COMPONENTS CO. LTD.www.srinutch.com
TURKEYCERAN AUTOMATIONwww.ceran.com.tr
UKRAINESENSORLINKwww.sensorlink.ru
USAWOERTZ-USAwww.woertz-usa.com cw/4.08
COMAT AG • BERNSTR. 4CH-3076 WORB
TEL. +41 (0)31 838 55 77FAX +41 (0)31 838 55 99
www.comat.ch • [email protected] GK0
8/6
.08e
EX