    2009 IBC, IRC, IFCCODE CHANGE HIGHLIGHTS

    Tim PateCo- Chair CCICC Code Change Committee

    Senior Plans Analyst, LEED AP

    City and County of Broomfield

  • 8/8/2019 Code Changes 1209

    2/82

    2

    IRC CHANGES

  • 8/8/2019 Code Changes 1209

    3/82

    3

    R105.2Work Exempt from Permit

    Accessory structures and detached decks

    that are 200 square feet or less areexempt from permits - if deck is over30 inches above grade or if it serves

    the main exit door it will still needpermit

  • 8/8/2019 Code Changes 1209

    4/82

    4

    R202Definitions

    Added definition of Attic, Habitable (70

    square feet minimum and headroomheights as per section R305) and

    added live load, emergency escapeand rescue, smoke alarm, and verticalegress requirements for these areas

  • 8/8/2019 Code Changes 1209

    5/82

    5

    R202Definitions

    Added the word plane to Story above

    grade since RB2 06/07 changed thescope of IRC to 3 stories above grade

    plane. This now matches the IBC

  • 8/8/2019 Code Changes 1209

    6/82

    6

    R202Definitions

    Definition of townhouse was changed

    from open space on two or more sidesto yard or public way on two or moresides since yard and public way both

    have definitions

  • 8/8/2019 Code Changes 1209

    7/82

    7

    R202Definitions

    Definitions of Stair (one or more risers)

    and Stairway (one or more flights ofstairs, interior or exterior, including

    landings and platforms) were addedand now match what is in the IBC

  • 8/8/2019 Code Changes 1209

    8/82

    8

    Section R302Fire Resistive Construction

    This section now has all of the fire resistiveconstruction requirements for exterior walls,

    projections, penetrations, party walls, andnew table for separation between house and

    garage. No technical changes except one

    hour fire rated party wall allowed intownhouses with fire sprinkler systems andFire separation requirements do not apply to

    two separate accessory structureslocated on same lot.

  • 8/8/2019 Code Changes 1209

    9/82

    9

    R308.4Hazardous Locations

    Glazing within 24 of either vertical edge

    of a door and lower than 60 abovefloor needs to be safety glazing.

    Exception was added for glazing that is

    adjacent to the fixed panel of slidingpatio doors

  • 8/8/2019 Code Changes 1209

    10/82

    10

    R311.3

    Floors and Landings atDoors

    Added exception for exterior balconies

    that are 60 square feet or less and onlyaccessible from that door

    do not need the 36 landing in thedirection of travel

  • 8/8/2019 Code Changes 1209

    11/82

    11

    R311.7.4Stair Treads and Risers

    Added scoping language to require all

    tolerance requirements (+ or 3/8 ontreads and risers) to be measured

    exclusive of carpets, rugs, or runners

  • 8/8/2019 Code Changes 1209

    12/82

    12

    R312Guards

    Guards are required when surface is

    located more than 30 inches abovefloor or grade below at any point within36 inches horizontally to the edge of

    the open side and the guard needs tobe 36 minimum high above adjacent

    fixed seating (benches)

  • 8/8/2019 Code Changes 1209

    13/82

    13

    R313 and P2904Sprinkler Protection

    Added new sections that will require fire

    sprinklers in all new townhouses uponadoption and fire sprinklers in all newsingle family homes as of January 1,

    2011 and P2904 gives details on howto design and install multipurpose

    sprinkler piping systems

  • 8/8/2019 Code Changes 1209

    14/82

    14

    R314Smoke Alarms

    New exception was added so that adding

    smoke alarms for installation,alterations, or repairs of plumbing or

    mechanical systems is not required but

    will still be required for all other interiorwork that requires permit

  • 8/8/2019 Code Changes 1209

    15/82

    15

    R315Carbon Monoxide Alarms

    Added requirements for carbon monoxide

    alarms in new dwellingswhen there is a fuel fired appliance or an

    attached garage - includesrequirements to add alarms for all

    permits to interior when there is a fuel

    fired appliance or an attached garage

  • 8/8/2019 Code Changes 1209

    16/82

    16

    R502.2.2.1Deck Ledger Connections

    This is a new section that gives

    prescriptive requirements for attachingdeck ledgers to the house rim boards

    Primarily requires lag bolts or throughbolts

  • 8/8/2019 Code Changes 1209

    17/82

    17

    R602.10Wall Bracing

    This section has been completely

    rewritten to provide technical accuracyand clarity. Code no longer

    differentiates between exterior and

    interior braced walls.

  • 8/8/2019 Code Changes 1209

    18/82

    18

    R612.3

    Window Fall PreventionDevices

    This section now requires window fall

    prevention devices (when bottom edgeof opening is less than 24 above floorand is more than 72 above exterior

    grade) to meet ASTM F 2090 whichwill meet emergency escape release

    mechanism requirements

  • 8/8/2019 Code Changes 1209

    19/82

    19

    R613

    Structural Insulated PanelWall Construction

    This section was added and gives all

    requirements for SIP wall constructionbut does not apply to floor or roofpanels

  • 8/8/2019 Code Changes 1209

    20/82

    20

    R806.1Attic Ventilation

    The minimum size of ventilation openings

    has been reduced from 1/8 to 1/16 toguard against entry of insects

    Potential problem with this smaller size ifwhen you paint over and seal up

    smaller holes

    T bl R905 2 4 1 d

  • 8/8/2019 Code Changes 1209

    21/82

    21

    Table R905.2.4.1 and

    IBC Table 1507.2.7Asphalt Roof Shingles

    These tables were added and include

    ASTM D 7158 D, G, or H as alternateapproved test standard for wind loadtesting for shingles

    AG 106 d IBC 3109 5

  • 8/8/2019 Code Changes 1209

    22/82

    22

    AG 106 and IBC 3109.5

    Swimming PoolEntrapment

    These sections in the IRC and IBC haveboth been changed for swimming pool

    entrapment avoidance to match therecently passed Virginia Graeme

    Baker Pool and Safety Act

  • 8/8/2019 Code Changes 1209

    23/82

    23

    IFC CHANGES

    IFC 102 1

  • 8/8/2019 Code Changes 1209

    24/82

    24

    IFC 102.1

    Construction and DesignProvisions

    The new exception clarifies that the IFC

    does not apply to the interior of singlefamily dwellings built under the IRC butdoes apply to the exterior of structure

    including premises identification, fireapparatus access and water supplies

    IFC 511

  • 8/8/2019 Code Changes 1209

    25/82

    25

    IFC 511

    Emergency ResponderRadio Coverage

    This section was added which will require

    an approved Emergency ResponderRadio Coverage system in all new and

    EXISTINGbuildings - no time frame for

    existing buildings

  • 8/8/2019 Code Changes 1209

    26/82

    26

    IFC 903.6.2Group I-2

    This section was added and will require

    fire sprinklers in all existing Group I-2occupancies (child care, detox,hospitals, mental hospitals, nursing

    homes). This is only located within theIFC and not the IBC and no timetable

  • 8/8/2019 Code Changes 1209

    27/82

    27

    ENERGY

    MECHANICALPLUMBING

    FUEL GAS

    CODE CHANGES

  • 8/8/2019 Code Changes 1209

    28/82

    28

    IRC ENERGY

    Approximately 15% more restrictive

    R-20 in exterior walls above gradeProgrammable thermostats at least one

    50% of light bulbs to be high efficacy

    Blower door test or visual inspectionfor air leakage

    Checking for duct leakage

    Heated swimming pools and snow melt systems

  • 8/8/2019 Code Changes 1209

    29/82

    29

    INTERNATIONAL ENERGYCONSERVATION CODE

    Approximately 15% more restrictive

    R-20 in exterior walls above gradeProgrammable thermostats at least one

    50% of light bulbs to be high efficacy

    Blower door test or visual inspectionfor air leakage

    Checking for duct leakage

    Heated swimming pools and snow melt systems

  • 8/8/2019 Code Changes 1209

    30/82

    30

    IRC M1411.6IMC 1101.10

    Locking access caps required for

    refrigerant circuit access ports that arelocated on exterior applies to airconditioning condensers also applies

    to commercial installations

  • 8/8/2019 Code Changes 1209

    31/82

    31

    IRC M1503.4

    IMC 505.2

    Exhaust hood systems capable ofexhausting in excess of 400 cfm willrequire makeup air to match needsto have means of closure and also

    automatically controlled to start andoperate at same time as the exhaust no requirement for make up air to be

    conditioned

  • 8/8/2019 Code Changes 1209

    32/82

    32

    IRC TABLE M1502.4.4.1

    IMC TABLE 504.6.4.1

    There is a new table that gives equivalent

    lengths of dryer exhaust duct fittingswhich you use when determiningallowable length of dryer exhaust ducts

    but you can still use manufacturersinstructions to determine length

  • 8/8/2019 Code Changes 1209

    33/82

    33

    IRC M1502.4.5

    IMC 504.6.5

    Where the cloths dryer exhaust duct is

    concealed within building construction,the equivalent length shall be identifiedon permanent tag and be within 6 feet

    of the duct connection

  • 8/8/2019 Code Changes 1209

    34/82

    34

    IRC M1502.5

    IMC 504.6.7

    Protective shield plates will now be

    required for clothes dryer exhaustducts that are closer than 1 tosurface of framing

  • 8/8/2019 Code Changes 1209

    35/82

    35

    IRC M1602.2

    Outdoor and return air cannot be taken

    from unconditioned attics or boilerrooms

  • 8/8/2019 Code Changes 1209

    36/82

    36

    IRC M2103.2

    IMC 1209.5

    Thermal barriers are now required for all

    radiant floor heating systems this willapply to either slab on grade (minimumR-5) or suspended floors

    (minimum R-11) and thermal breaksrequired where heated slabs meet

    foundation walls

  • 8/8/2019 Code Changes 1209

    37/82

    37

    IRC G2411.1

    IFGC 310.1.1

    CSST gas piping systems shall be bonded tothe electrical service grounding electrodesystem at the point where the gas serviceenters the building and bonding jumper

    needs to be at least 6 AWG copper wire orequivalent or check manufacturersinstallation requirements

  • 8/8/2019 Code Changes 1209

    38/82

    38

    IRC G2415.4

    IFGC 404.4

    Gas piping shall not penetrate building

    foundation walls at any point belowgrade

  • 8/8/2019 Code Changes 1209

    39/82

    39

    IRC P2503.6

    IPC 312.9

    Shower liner tests are now required and

    specific requirements are listed

  • 8/8/2019 Code Changes 1209

    40/82

    40

    IRC P2904

    Section 2904 was added and gives

    design and installation requirementsfor dwelling unit fire sprinkler systemsand is an equivalent to an NFPA 13D

    fire sprinkler system- the designdrawings will need to be provided

    before permit issuance

  • 8/8/2019 Code Changes 1209

    41/82

    41

    IPC Table 403.1

    Required Plumbing Fixtures

    Footnote f was added to Table 403.1

    which gives exception for when youhave 15 or fewer occupants then youare not required to have two drinking

    fountains

    IMC S i

  • 8/8/2019 Code Changes 1209

    42/82

    42

    IMC Section 403

    Mechanical Ventilation

    Section 403 was substantially revised and

    alters the airflow requirements alongwith the way they are calculated. Italso references breathing zones. This

    will bring these in line with theASHRAE 62.1 - 2004 requirements.

    This also helps in energy efficiency.

  • 8/8/2019 Code Changes 1209

    43/82

    43

    IBC CHANGES

  • 8/8/2019 Code Changes 1209

    44/82

    44

    202 Definitions

    The definition for Labeled has been

    added to reflect how approved testinglabs, inspection agencies, or otheragencies that do product evaluations

    do the labeling for products.

    304 1

  • 8/8/2019 Code Changes 1209

    45/82

    45

    304.1

    Business Group B

    Ambulatory health care facilities were addedalong with new section 422 for specific

    requirements - fire sprinklers, fire alarms,smoke compartments. Ambulatory health

    care facilities are medical, surgical,psychiatric, nursing or similar care - less

    than 24 hours - incapable of self

    preservation (24 hours or more still I-2)

    308 5 1

  • 8/8/2019 Code Changes 1209

    46/82

    46

    308.5.1

    I-4 Adult Care Facility

    Adult care facilities provide accommodations forless than 24 hours for more than five

    unrelated adults and provides supervisionand personal care.

    Changed the exception from A-3 to R-3.If the occupants are capable of responding to

    emergency without assistance then it can be

    classified as R-3

    310 1

  • 8/8/2019 Code Changes 1209

    47/82

    47

    310.1

    Residential Group R

    Will allow a R-1 transient congregate

    living facility with occupant load of 10 orless to be classified as R-3

    Condos in ski towns

    402 6 1

  • 8/8/2019 Code Changes 1209

    48/82

    48

    402.6.1

    Reduced Open Space

    This section was added and will allow

    reduced open space (40) for unlimitedarea malls. This will match reducedopen space for regular buildings

    403 6 1

  • 8/8/2019 Code Changes 1209

    49/82

    49

    403.6.1

    Fire Service Elevator

    This section was added and will require a

    fire service access elevator for allbuildings with an occupied floor morethan 120 feet above fire department

    vehicle access and refers to newSection 3007 for requirements - this

    does not require separate elevator

    Table 403 2 4

  • 8/8/2019 Code Changes 1209

    50/82

    50

    Table 403.2.4

    Minimum Bond Strength

    This table was added and gives higher

    SFRM minimum bond strengths for highrise buildings - 430 psf for building 75 to420 and 1,000 psf for buildings over 420

    Higher bond strength means bettercohesion to steel members

    403 5 2

  • 8/8/2019 Code Changes 1209

    51/82

    51

    403.5.2

    Additional Exit Stairway

    This section was added and will require anadditional exit stair for all buildings (other than

    R-2) with an occupied floor more than 420 feetabove fire department vehicle access - not

    required when elevator complying with section3008 (Occupant Evacuation Elevator) is

    installed - more restrictive than Fire Service

    Access Elevator

    403 5 5

  • 8/8/2019 Code Changes 1209

    52/82

    52

    403.5.5

    Egress Path Markings

    This section was added and will requireluminous egress path markings for highrise buildings and refers to new section1024 for details. IFC Section 4604.23

    requires these egress path markings tobe added to all existing high rise

    buildings - no timetable

    419

  • 8/8/2019 Code Changes 1209

    53/82

    53

    419

    Live Work Units

    This section was added and givesrequirements for Live Work occupancies

    Possible amendments:

    Refer to IBC Chapter 29 for plumbingfixture requirements

    Refer to IBC Chapter 10 for exit system

    requirements

    Table 503

  • 8/8/2019 Code Changes 1209

    54/82

    54

    Allowable Height andBuilding Areas

    B, M, S-1, and S-2 allowable stories wereall reduced for Type IIB and IIIB

    construction - B went from 4 to 3, Mwent from 4 to 2, S-1 went from 3 to 2,

    and S-2 went from 4 to 3. Attempted toreduce R from 4 to 3 but was defeatedsince all R occupancies require

    sprinklers

    508 2

  • 8/8/2019 Code Changes 1209

    55/82

    55

    508.2

    Accessory Occupancies

    This section was completely changed withemphasis on clarifying that incidental use

    areas are a subset of accessoryoccupancies. Storage and parking

    garages were also deleted from Table508.2.5

    509.2

  • 8/8/2019 Code Changes 1209

    56/82

    56

    Horizontal BuildingSeparation Allowance

    This section has been modified to allowR occupancies on the level below the 3

    hour rated horizontal separation - now willallow B, M, R, multiple A (with occupant

    load under 300) and incidental uses(storage areas, mechanical areas,

    lobbies)

  • 8/8/2019 Code Changes 1209

    57/82

    57

    509.5 and 509.6

    Both sections have added R-1 toallowable occupancies in buildings of

    Type IIIA and IIA that can have increasedheight and stories - now will be R-1 and

    R-2

    509.9

  • 8/8/2019 Code Changes 1209

    58/82

    58

    Multiple buildings aboveparking garages

    Section 509.9 (Multiple buildings above anenclosed or open Group S-2 parking garage)

    This section was added to provide clarity that ifthere are two properly separated buildings

    above an S-2 garage and built in accordancewith sections 509.2 or 509.3, they shall beregarded as separate and distinct buildings

  • 8/8/2019 Code Changes 1209

    59/82

    703.6

  • 8/8/2019 Code Changes 1209

    60/82

    60

    703.6

    Marking and Identification

    This section was added and will require all fireand smoke rated walls to be permanently

    identified with signs or stenciling - onlyexception is R-2s that do not have removabledecorative ceiling allowing access - problems

    might be rated exterior walls and otheroccupancies with hard ceilings.

    704.1.1

  • 8/8/2019 Code Changes 1209

    61/82

    61

    704.1.1

    Primary Structural Frame

    This section has added bracing membersthat are essential to the vertical

    stability of the primary structural frameunder gravity loads to be considered

    part of the primary structural frame -this relates to fire protectionrequirements in Table 601

    706.5.1

  • 8/8/2019 Code Changes 1209

    62/82

    62

    706.5.1

    Fire Walls

    This section has added wording thatrequires using an imaginary lot line toextend out from the intersection of afire wall at exterior wall in order to

    verify requirements for exterior walland opening protection

    706.8

  • 8/8/2019 Code Changes 1209

    63/82

    63

    Openings

    This section was changed so that theallowable size of fire rated openings infire walls went from 120 square feet to

    156 square feet - still cannot have

    openings in party walls and still canhave any size openings when building

    has NFPA 13 sprinkler system

    708.2

  • 8/8/2019 Code Changes 1209

    64/82

    64

    Shaft Enclosure Required

    Exception 14 was added and will exemptelevators in open and enclosed

    parking garages that only serve theparking garage. Exception 15 was

    added and will exempt mechanicalshafts in parking garages

    708.14.1

  • 8/8/2019 Code Changes 1209

    65/82

    65

    Elevator Lobby

    Elevator lobbies are now required inGroup I-2 occupancies (detox, childcare, hospital, nursing home) and

    exception 7 was added which exempts

    elevators serving only open parkinggarages from needing an elevator

    lobby

    714.1 Exception 5

  • 8/8/2019 Code Changes 1209

    66/82

    66

    p

    Joints

    This section has added wording thatexempts joints in fire resistive walls,ramps, and floors within enclosedparking garages matches open

    parking garages

  • 8/8/2019 Code Changes 1209

    67/82

    67

    903.2.2 Group E

    The threshold for requiring a fire sprinklerin E occupancies was reduced from20,000 square feet down to 12,000

    square feet

  • 8/8/2019 Code Changes 1209

    68/82

    68

    903.2.6 Group M

    Group M occupancies which are usedprimarily for the display and sale of

    upholstered furniture will require firesprinklers furniture that has padding

    inserts not mattresses and boxsprings as per CPSC

    THIS DOES NOT HAVE ANY SIZE

    THRESHOLD

    903.2.9

  • 8/8/2019 Code Changes 1209

    69/82

    69

    Group S-2

    This section now requires a sprinklersystem when the fire area of enclosedparking garages exceeds 12,000 s. f.,or exceeds three stories above grade

    plane, or total fire areas exceed 24,000s.f., or fire area exceeds 5,000 s.f for

    storage of commercial trucks

    Table 1005.1

  • 8/8/2019 Code Changes 1209

    70/82

    70

    Egress Width

    Table 1005.1 was deleted along with

    the sprinkler exception to reduce exitwidths - .3 inch per occupant for stairs

    and .2 inch for all other egress

    components is to be used for anybuilding and space - potential problemmay be existing building - use section

    3412

    1007.3 and 1007.4

  • 8/8/2019 Code Changes 1209

    71/82

    71

    Exit Stairs and Elevators

    Both sections have exception added backfor a fire sprinkler system in lieu of the

    required areas of refuge but newsection 1007.8 was added and two

    way communication systems are nowrequired at all elevator landings even ifbuilding has approved sprinkler system

    1007.6.2

  • 8/8/2019 Code Changes 1209

    72/82

    72

    Required Separation ofAreas of Refuge

    Areas of refuge are required to beseparated by a smoke barrier. Theword vertical was deleted from theexception. Areas of refuge can be

    located within an exit enclosure whichcould include an exit passageway

    1007.8

  • 8/8/2019 Code Changes 1209

    73/82

    73

    Two Way Communication

    This section was modified and givesspecific requirements for two way

    communication systems for areas ofrefuge and at elevator landings

    1008.1.2

  • 8/8/2019 Code Changes 1209

    74/82

    74

    Door Swing

    Exception 9 was added and allowsmanually operated horizontal sliding

    doors from spaces with occupant loadof 10 or less - similar to exception 1

    1009.4.1

  • 8/8/2019 Code Changes 1209

    75/82

    75

    Dimension ReferenceSurfaces

    This section was added and requires thatstair treads and risers need to meetthe required dimensions exclusive of

    carpets, rugs, or runners

    1009.4.5

  • 8/8/2019 Code Changes 1209

    76/82

    76

    Profile

    Exception 2 now allows open risers in F,H, and S occupancies where not

    accessible to the public

    1009.12

  • 8/8/2019 Code Changes 1209

    77/82

    77

    Handrails

    Handrails are only required on 4 or morerisers within R-2 and R-3 occupancies previously required for 2 or more -

    now matches the IRC - now only

    difference between IBC and IRC isguard needs to be 42 high in IBC

    dwelling units

    1009.13

  • 8/8/2019 Code Changes 1209

    78/82

    78

    Guards

    Guards will be required when surface islocated more than 30 inches measuredvertically to the floor or grade below atany point within 36 inches horizontally

    to the edge of open side

    1014.3

  • 8/8/2019 Code Changes 1209

    79/82

    79

    Common Path ofEgress Travel

    Exception 4 now allows 125 footmaximum travel distance in R-2

    occupancy when you have 13R system previously just for 13 system

    1021.2 and Table 1021.2

  • 8/8/2019 Code Changes 1209

    80/82

    80

    Single exits

    Section 1021.2 and Table 1021.2 havebeen modified by changing the word

    building to stories for the requirementsfor only allowing a single exit

    1507.16

  • 8/8/2019 Code Changes 1209

    81/82

    81

    Roof Gardens andLandscaped Roofs

    This section was added and refers you tosections 1607.11.2.2 and 1607.11.2.3

    for design requirements

  • 8/8/2019 Code Changes 1209

    82/82

    82

    2009 CODE CHANGES

    You can go up on the ICC websitewww.iccsafe.org and get more specific

    information about all previous codechanges. If you need additional

    information please contactTim Pate at [email protected]