CMS Fixed Tube

3
engineered heat transfer solutions CMS www.cmsheattransfer.com 1 Standardized Fixed Tubesheet Exchangers Single Pass CMS Single Pass Standardized Fixed Tubesheet Exchangers have been manufactured to the specifications displayed. Units can be provided in accordance with ASME Sect. VIII, Sect. V, Sect. IX of the Boiler and Pressure Vessel Code, TEMA, API, HEI, and 3 A standards. In addition, our designs can incorporate all your specifications to insure compliance with your plant standards. 6 5/8 8 5/8 10 3/4 12 3/4 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 10 12 14 15 18 18 19 23 23 23 27 27 31 31 35 35 38 38 38 8 7/8 10 7/8 10 7/8 11 7/8 12 7/8 13 7/8 13 7/8 16 7/8 16 7/8 16 7/8 19 7/8 19 7/8 22 7/8 22 7/8 26 26 29 29 29 11 1/4 13 17 17 1/2 22 22 1/2 24 1/4 29 29 1/4 29 5/8 35 7/8 36 3/8 40 40 1/2 40 3/8 44 7/8 49 3/8 49 3/4 50 3/8 9 1/8 10 7/8 11 1/8 11 5/8 12 3/4 14 1/4 15 17 1/8 17 3/8 17 3/4 20 7/8 21 3/8 24 5/8 25 1/8 26 5/8 27 1/8 31 5/8 32 32 5/8 5 6 6 7 8 8 8 10 10 10 12 12 14 14 16 16 17 17 17 8 5/16 9 5/16 10 3/8 11 3/8 12 16 14 15 16 17 18 19 20 21 23 24 25 26 27 3 4 6 6 8 8 8 10 10 10 12 12 14 14 16 16 18 18 18 1 2 2 2 3 3 3 4 4 4 4 4 6 6 6 6 8 8 8 2 3 3 4 6 6 6 8 8 8 8 8 10 10 12 12 14 14 14 2 3 3 4 6 6 6 8 8 8 8 8 10 10 12 12 14 14 14 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 1 1 1 1 1 1 1 1 1 Shell O.D. H J K L M N A B C D E N N B C E E E E D A *F *G L J K H M O CMS Heat Transfer Division, Inc. Email: [email protected] Tel: 631.968.0084 Fax: 631.968.0184 273 Knickerbocker Avenue, Bohemia, NY 11716

description

F

Transcript of CMS Fixed Tube

engineered heat transfer solutionsCMSwww.cmsheattransfer.com

1

Standardized Fixed Tubesheet Exchangers

Single PassCMS Single Pass Standardized Fixed Tubesheet Exchangers have been manufactured to the specifications displayed. Units can be provided in accordance with ASME Sect. VIII, Sect. V, Sect. IX of the Boiler and Pressure Vessel Code, TEMA, API, HEI, and 3 A standards. In addition, our designs can incorporate all your specifications to insure compliance with your plant standards.

6 5/88 5/8

10 3/412 3/4

141618202224262830323436384042

10121415181819232323272731313535383838

8 7/810 7/810 7/811 7/812 7/813 7/813 7/816 7/816 7/816 7/819 7/819 7/822 7/822 7/8

2626292929

11 1/41317

17 1/222

22 1/224 1/4

2929 1/429 5/835 7/836 3/8

4040 1/240 3/844 7/849 3/849 3/450 3/8

9 1/810 7/811 1/811 5/812 3/414 1/4

1517 1/817 3/817 3/420 7/821 3/824 5/825 1/826 5/827 1/831 5/8

3232 5/8

5667888

101010121214141616171717

8 5/169 5/1610 3/811 3/8

121614151617181920212324252627

3466888

101010121214141616181818

1222333444446666888

233466688888

10101212141414

233466688888

10101212141414

3/43/43/43/43/43/43/43/43/43/4111111111

Shell O.D. H J K L M N A B C D E

NN

NN

B C E E

E E

D A

*F*G

LJ

KH

MO

CMS Heat Transfer Division, Inc.Email: [email protected]

Tel: 631.968.0084 Fax: 631.968.0184273 Knickerbocker Avenue, Bohemia, NY 11716

engineered heat transfer solutionsCMSwww.cmsheattransfer.com

2

Standardized Fixed Tubesheet Exchangers

Single Pass Tube Side, 3/4” O.D. Tubes 15/16” Change In PitchCMS Single Pass Standardized Fixed Tubesheet Exchangers have been manufactured to the specifications displayed. Units can be provided in accordance with ASME Sect. VIII, Sect. V, Sect. IX of the Boiler and Pressure Vessel Code, TEMA, API, HEI, and 3 A standards. In addition, our designs can incorporate all your specifications to insure compliance with your plant standards.

NN

NN

B C E E

E E

D A

*F*G

LJ

KH

MO

6 5/88 5/8

10 3/412 3/4

141618202224262830323436384042

315585

126154212268349421502596696815929

10541181133714751639

24436799

121167211274331395468546640730828927

105011581287

3765

100149482250316412497592702820960

109412421391157517371930

4987

134198242334422549663790936

10931280145916551854210023162574

61108167248302417528686829988117013661600182420692318262528953217

8 5/169 5/1610 3/811 3/8

121614151617181920212324252627

8515123434642358473996011601382163819122240255228973245367440544504

98173267396484667845

109813261580187221862560291833103709419946335148

110195300446545751951

123514921778210624592880328337244172472452155791

122216334495605834

1056137216581976234027323200364841384636524957916435

Shell O.D. No. TubesSquare Feet Surface for Tube Length

4’-0” 6’-0” 8’-0” 10’-0” 12’-0” 14’-0” 16’-0” 18’-0” 20’-0”

CMS Heat Transfer Division, Inc.Email: [email protected]

Tel: 631.968.0084 Fax: 631.968.0184273 Knickerbocker Avenue, Bohemia, NY 11716

At CMS Industries we’ll put our years of heat transfer “know-how” to work for you. In

addition to sizing a shell & tube heat exchanger for your specific heat transfer needs, our

engineers incorporate measures to insure ease of maintenance and longer equipment life

- this equates to both smaller initial capital and maintenance costs over the years.

Code conformance and certification

Our products are engineered to meet rigid standards,

and quality is always the first priority. Units can be

provided in accordance with ASME Sect. VIII, Sect. V

and Sect. IX of the Boiler and Pressure Vessel Code,

TEMA, API, HEI, and 3A standards. In addition, our

designs can incorporate all of your specifications to

insure compliance with your plant standards.

Engineering support

Mechanical design

Process design

It is our engineering department’s primary goal to

provide the best technical support required to solve your

heat transfer problems. With the aid of state-of-the-art

integrated software our engineers can rate and size the

appropriate equipment for your application.

Our products can be fabricated in a variety of materials

including cupro-nickel, carbon and stainless steels and

nickel alloys. Correct material selection will insure long

life of the exchanger even in the most corrosive

services. In addition, our engineers will incorporate the

appropriate configuration in the design of your unit to

insure ease of maintenance and the ability to withstand

the most vigorous thermal and mechanical demands.

At CMS we have the expertise to solve all of your process

heat transfer needs. With the use of state-of-the-art

software, we can size and rate a shell and tube heat

exchanger to your exact specifications. Single and two-

phase-flows, liquid-to-liquid, single and multiple

condensable in the presence of or absence of non-

condensables, no process is too complex. Our engineers

will provide the technical support to insure a proper

design. It’s like having a process engineer on staff.

For “Those ProblemsThat Won’t Go Away”

Custom Design

Process Design Support

Design of All

Shell and TubeHeat Exchangers

Oil Coolers

Fuel Oil Pre-Heaters

Aftercoolers

Steam Converters

Condensers

Kettles

Thermo-Syphon Reboilers

Falling Film Evaporators

For “Old Reliable”

Replacement Bundles

XLE Units

Generator Coolers

OEM Replacement Units

Retubing & Reconditioning

Service beyond the expected

Experienced in allphases of heatexchangetechnologies

TEMA Configurations

engineered heat transfer solutionsCMSwww.cmsheattransfer.com

3

CMS Heat Transfer Inc.

CMS Heat Transfer Division, Inc.Email: [email protected]

Tel: 631.968.0084 Fax: 631.968.0184273 Knickerbocker Avenue, Bohemia, NY 11716