CMRL Facilities for Disabled Newsletter April-2012
-
Upload
vaishnavi-jayakumar -
Category
Documents
-
view
11 -
download
1
description
Transcript of CMRL Facilities for Disabled Newsletter April-2012
Caption describing pic-ture or graphic.
The true
sign of
intelligence
is not
knowledge
but
imagination.
AlbertEinstein
Page 2 Chennai Metro Rail Newsletter
Facilities Planned for Physically Challenged Persons inChennai Metro Stations and Coaches
The facilities for Physically Challenged persons within the station will generally be provided basedon Guidelines and space standards for Barrier Free Built Environment for Disabled andElderly Persons". Also, the design in general will be in accordance with "Guidelines and SpaceStandards for Barrier Free Built Environment for Disabled and Elderly Persons", Central PublicWorks Department, Ministry of Urban Affairs & Employment, 1998.The following facilities are planned to be provided within the station for Physically ChallengedPersons:
In Metro Stations:* Signages within and outside the station to guide the per-sons.* Dedicated parking space subject to space availability.* Non slippery floors and well lit passages.* Convenient design of station structure for free movement.* Dedicated tactile tiles to access for the functional areas andplatforms.* Bumpy tiles to alert customers who are blind or have lowvision that they are nearing the edge of the platform.* Accessible toilets.* Ticket issuing window and Ticket Vending Machine count-ers with accessible heights.* Dedicated Automatic Fare Collection (AFC) gates.* Induction loops at ticket counters for hearing impairedpassengers.* Simple and Uniform Terminal Design avoiding glossy sur-faces/glasses.* Ramp as per standards and with handrail.* Adequate landing space at the start and end of every ramp.* Stair cases as per standards with handrails.* Steps with contrasting coloured nosing or anti skidding tiles at the edge of the steps will be pro-vided for easy access.* Adequate seating arrangement in platform
Coaches:General*Dedicated Seating facilities in the train.*Easy access to the cars for persons with disabilities, including wheelchair users, shall be providedthrough the side doors.*The rake shall be a high-floor design, with level boarding from platforms. Wheelchair and mobil-ity-impaired boarding shall not require the use of bridging or lifting devices. The horizontal gapbetween the passenger door thresholds and platform edge at rest shall not exceed 50 mm in nomi-nal operating conditions, and 75 mm maximum. The maximum vertical gap between the passen-ger door thresholds and platform edge shall not exceed 31 mm in nominal operating conditions.In no cases (including the worst operating conditions) shall the top surface of the horizontalthreshold of the car be lower than the top edge of the platform. The gap between platform andthe rail car enables wheelchair users to enter and exit the train safely.*At least two wheelchair parking areas shall be available in each driver car of the 4-car rakes.Four seats shall be available for the elderly and handicapped passengers in all driver car ends.
Continued….
In Lifts :*Lift in street level at conven-ient location and lift facilitywithin the station.*Lift cars with required spaceand wide doors.*Audio announcement andBraille facilities within lift. Signsprinted in Braille in the lifts toindicate floors as well as visual/audible announcements.*Grip rails on 3 walls inside theelevator car.*Elevator control buttons posi-tioned at convenient heights.
Source : April 2012 CMRL Newsletter Page 2 & 3 http://www/chennaimetrorail.gov.in/newsletter/April-2012.pdf
Page 3Volume-II Issue-4
Success is
the ability to
go from one
failure to
another with
no loss of
enthusiasm.
WinstonChurchill
*Seats shall be provided for handicapped persons.*The designated areas for wheelchair parking shall be located adjacent to an accessible entrance andshall be compliant with all ADA requirements.*Wheelchair users must be able to exit the car from any wheelchair parking position through eitherof at least two accessible doors (on the same side of the train).Wheelchair Egress Request*A wheelchair egress request signal shall be provided which shall permit a passenger in any car of atrain to alert the operator to stop the car for a prolonged time to enable wheelchair passengers toexit the train. This system shall be ADA compliant and accessible to wheelchair-seated passengers.*The stop request shall consist of the following and shall be inhibited when doors are open.
Stop-request strips shall be located at wheelchair accommodations.An audible-non-repeating chime and alarm light shall be installed in each operator’s cab area.
Progress of Depot work as on 30-4-2012
The progress of depot works as on 30-4-2012 is given below:
Sl. No. Description Unit Quantity exe-cuted
1 Earth filling Cum 1,86,0202 Installation of Prefabricated Ver-
tical Drain (PVD)RMT 16,84,124
3 Surcharge filling Cum 2,04,1214 Admn building (work
pile)600mmNo. 229
5 Piles for infrastructure shed,stabling shed, rolling stock andworkshop 500 mm
No. 807
Total quantity
3,16,00020,43,700
4,22,354229
995
6 Admn building & infrashed pilecap
No. 116 90
7 Viaduct and ramp area 1000 mm No 63 638 Viaduct pile cap No 19 3
Viaduct pile cap work nearKoyambedu depot
Roof slab work in progress for adminbuilding at Koyambedu depot