CM 1000 - Abbott Technologies...CM 1000 1000 Watt AC-DC Switchers Options available: - Droop (Zero...

2
CM1000 1000 Watt AC-DC Switchers Options available: - Droop (Zero Wire) Current Sharing - Forced Current Sharing - Internal ORing Diode ©2017 Abbott Technologies, Inc. AT 2905B 6/2017 MBE Certified Minority Business Enterprise n SBA Certified Woman-Owned n Minority Business Enterprise (MBE) n HUBZone Certified n ISO9001 and AS9100 Certified n QPL Certified products n NAICS Codes: 334416, 334419, 335311, 335999 n DUNS: 36-065-1954 n Cage Code: 58910 8203 Vineland Ave l Sun Valley, CA 91352 (818) 504-0644 l Sales (800) 367-8200 Technical Support (818) 504-0644 AbbottTechnologies.com Rock Solid Reliability for over 50 years. MADE IN U. S. A. Features: - Power Factor Correction - Compliant with MIL-STD-461, CE101, and CE102 - Meets MIL-S-901 (High Impact Shock) - Meets applicable MIL-STD-810 - CM1000 fully sealed to meet IP65 (Optional connectors available to meet IP67) CM1000 AbbottTechnologies.com

Transcript of CM 1000 - Abbott Technologies...CM 1000 1000 Watt AC-DC Switchers Options available: - Droop (Zero...

  • CM10001000 Watt AC-DC Switchers

    Options available:- Droop (Zero Wire) Current Sharing

    - Forced Current Sharing

    - Internal ORing Diode

    ©2017 Abbott Technologies, Inc. AT 2905B 6/2017

    MBECertified Minority

    Business Enterprise

    n SBA Certified Woman-Ownedn Minority Business Enterprise (MBE)n HUBZone Certifiedn ISO9001 and AS9100 Certifiedn QPL Certified products

    n NAICS Codes: 334416, 334419, 335311, 335999

    n DUNS: 36-065-1954n Cage Code: 58910

    8203 Vineland Ave l Sun Valley, CA 91352(818) 504-0644 l Sales (800) 367-8200

    Technical Support (818) 504-0644

    AbbottTechnologies.com

    Rock Solid Reliability for over 50 years. MADE IN

    U. S. A.

    Features:

    - Power Factor Correction

    - Compliant with MIL-STD-461, CE101, and CE102

    - Meets MIL-S-901 (High Impact Shock)

    - Meets applicable MIL-STD-810

    - CM1000 fully sealed to meet IP65

    (Optional connectors available to meet IP67)

    CM1000

    AbbottTechnologies.com

  • For Extreme Environments

    3 Power Factor Correction3 Compliant with MIL-STD-461, CE101, and CE102 3 Meets MIL-S-901 (High Impact Shock)3 Meets applicable MIL-STD-810 3 Fully sealed to meet IP65 (Optional connectors available to meet IP67)

    Options: Droop (Zero Wire) Current Sharing, Forced Current Sharing (up to 4 modules for a total of 4,000 watts)Internal ORing Diode

    Specifications:

    Model Number System

    Any specifications subject to change without notice.

    Model Family (CM1000 = 1000 Watt Output)

    S = Standard Connector (Unit meets IP65) or M = Fully Sealed Waterproof Connector (Unit meets IP67)C = Condensing Humidity Environment

    Voltage Output (see chart to right for Voltage options and Max Current)

    Example as shown above: CM1000 - 1000 Watt Output with Standard Connector, 28 Volt

    Maximum Current Output Rating

    Output Voltage Max Current12V 75A*

    13.6V 73.5A

    15V 66.7A

    24V 41.7A

    28V 35.7A

    48V 20.8A

    Ordering Information:

    AbbottTechnologies.com

    CM1000 S 28

    Call our Technical Support Department with questions: (818) 504-0644

    UNLESS OTHERWISE SPECIFIED

    DO NOT SCALE DRAWINGFINISH

    -

    TOLERANCES ARE:DIMENSIONS ARE IN INCHES.

    DECIMALS ANGLES

    C

    B11165-20CAD FILE NO

    APPLICATION

    NEXT ASSY

    -

    USED ON

    USED ON

    WARNING: THIS DOCUMENT CONTAINS TECHNICAL DATAWITHIN THE DEFINITION OF THE INTERNATIONAL TRAFFIC IN ARMSREGULATIONS (ITAR) AND IS SUBJECT TO THE EXPORT CONTROL LAWSOF THE US GOVERNMENT TRANSFER OF THIS DATA BY ANY MEANS TOA FOREIGN PERSON, WHETHER IN THE UNITED STATES OR ABROAD,WITHOUT AN EXPORT LICENSE OR OTHER APPROVAL FROM THE U.S.DEPARTMENT OF STATE, IS STRICTLY PROHIBITED.

    J

    J1-A AC INPUT (LINE)

    J1-B VDC OUTPUT RTN (-)

    J3-A +SENSE

    J2-A VDC OUTPUT (+)

    J1-C CHASSIS GROUNDJ1-B AC INPUT (NEUTRAL)

    J3-F RETURNJ3-E NC

    28VDC@ 35.7A

    J3-C CURRENT SHAREJ3-B -SENSE

    TECHNOLOGIES, INC.TECHNOLOGIES, INC.

    95-260 VRMS 47-440HzMFR58910-CM1000S28

    J1 J3 J2

    A BAC

    B

    9.00

    (228

    .60)

    .75

    (19.

    05)

    1.90

    0(4

    8.26

    )

    6.00 (152.40)

    F

    DC

    EB

    A

    J3-D N INHIBIT

    .926

    (2.2

    2)

    9.00

    (228

    .60)

    .900 (22.90)

    .93 (2.23)

    1.44(36.58)2.95(74.93)

    N

    DIMENSION IN PARENTHESIS ( ) ARE IN MILLIMETERS.

    3.75

    0(9

    5.25

    )

    5.500(139.70)

    3.75

    0(9

    5.25

    )

    *Output power limited by connector current rating. Please contact technical support for alternative connector information.

    AC Input:95-260 VAC, 47-440Hz, Single Phase,Power Factor Corrected. Meets MIL-STD-1399, Section 300, Type 1 Requirements (Spike Voltage Test)

    Efficiency:80% Minimum (88% Typ; 28 VDC

    Model at 100% Load)

    Line Regulation:+1% of Nominal over the Full Range of Line Input Voltage

    Load Regulation:+1% for Change from No Load to Full Load

    Ripple and Noise:Peak-to-peak combined Ripple and Noisedoes not exceed 2% of Nominal on theOutput Measured with a 20MHz bandwidth

    Temperature Range:Storage, Transport and Handling:

    -50°C to + 85°CAmbient Temperature:

    -40°C to 70°C

    Baseplate Temperature:-40°C to +70°C with no Power Derating

    Overtemperature Protection:Output shut down if maximum case temperature limit is exceeded

    Isolation:Input to Output: 1500 VDCInput to Case: 1500 VDCOutput to Case: 500 VDC

    Short Circuit Protection:Each unit is completely protected againsta short circuit of any duration. The currentlimit circuit nominally set at 120% of fullload to reduce voltage. Output is latchedunder short circuit condition. Auto-recoveryfrom short circuit option is available.

    Remote Error Sensing:Standard

    Input Protection:Internal Fuse

    Control Features:INHIBIT (TTL LOW = TRUE)

    Reliability: MTBF 124,545 calculated per MIL-HDBK-217Fn.2/25C/Full Load Ground Benign Environment

    Electromagnetic Compatibility: Meets the following MIL-STD-461 requirements: CE101, CE102

    Outline Dimensions: Refer to Mechanical drawings on opposite page

    Weight: 5.5lbs Typical

    Environmental Conditions:Shock Test: Unit meets MIL-S-901

    requirements (lightweight)Vibration Test: Unit meets MIL-STD-167,

    Type 1 requirementsHumidity Test: Power supply operates

    without any evidence of degraded performance in non-condensing relativehumidity up to 95%

    J1

    B

    C A

    J2J3

    BA

    MS3102R24-9S

    J2-A VDC OUTPUT (+)J2-B VDC OUTPUT RTN (-)

    MS3110E10-6S

    J3-A +SENSEJ3-B -SENSEJ3-C CURRENT SHAREJ3-D N INHIBITJ3-E NCJ3-F RETURN

    MS3102R16-10P

    J1-A AC INPUT (LINE)J1-B AC INPUT (NEUTRAL)J1-C CHASSIS GROUND

    9