CLOUD MULTI-CHANNEL POWER AMPLIFIERS Clearly better sound · 2014-03-22 · Other standard options...
Transcript of CLOUD MULTI-CHANNEL POWER AMPLIFIERS Clearly better sound · 2014-03-22 · Other standard options...
C l e a r l y b e t t e r s o u n d
Cloud Electronics Limited140 Staniforth Road, Sheffield, S9 3HF. England. Telephone: +44 (0)114 244 7051 Fax: +44 (0)114 242 5462 Web: www.cloud.co.uk Email: [email protected]
The Cloud CX-A450 and CX-A850 are high-quality multi-channel power amplifiers designed for relatively low-power sound reinforcement applications in commercial or industrial premises. They are ideal for situations where the various locations of the building require different programme material and/or levels.
The two models are:
MODEL POWER
CX-A450 4 x 50 W
CX-A850 8 x 50 W
The amplifiers will deliver their rated power into 4 ohm loads for long periods of time. Safety features of the design include Cloud’s Dynamic Clipping Protection circuitry, VI limiting, switch-on delay (5 seconds) and protection against DC offset or thermal overload. Both models are built in a 2U steel enclosure, and use variable–speed forced-air cooling.
Any two channels may be wired in Bridge Mode, allowing power outputs of double the normal rating to be delivered to a load of 8 ohms (minimum).
In addition to the power switch and associated LED, the front panel is fitted with three LEDs for each channel, confirming signal presence, peak level and activation of the protection circuitry. Rear panel controls are provided for individual channel gain trims and input routing to configure the amplifier in various combinations of mono, stereo or multi-channel operation. The inputs are electronically balanced.
The CX-A450 and CX-A850 may also be used with 100 V/70 V-line loudspeaker systems by the addition of standard Cloud accessories. The CXL-4160 is a four channel transformer module which can be internally fitted to the CX-A450, while the CXL-40T is a single channel toroidal transformer module for external mounting. For installation convenience, the CXL-800, a 2U rackmounting assembly which can hold up to eight CXL-40s, is also available. To prevent LF transformer saturation in 100 V/70 V-line systems, a 65 Hz high-pass filter may be enabled for each channel individually, by internal jumper.
Other standard options are Cloud RL-1 remote volume control plates, the VCA-5 single-channel VCA card (required for level control by RL-1), and EQ cards to suit various makes and models of loudspeakers. Remote level control or speaker EQ may be fitted to any or all channels.
Cloud CX-A450 - front panel view
Cloud CX-A850 - front panel view
CX-A450
FOUR CHANNEL POWER AMPLIFIER
PROTECT
PEAK
SIGNAL
POWER
4 3 2 1
EIGHT CHANNEL POWER AMPLIFIER
CX-A 850
12345678
PROTECT
PEAK
SIGNAL
POWER
CH 1REMOTELEVEL 1 2 3
RL-1
1 2 3
CH 2REMOTELEVEL
RL-1
21 3
321
CH 3REMOTELEVEL
RL-1
21 3
321
CH 4REMOTELEVEL
RL-1
21 3
321
1
321LEVEL
2
321LEVEL
3
321LEVEL
4
321LEVEL
POWER INPUT
FUSEREPLACE FUSEWITH SAME TYPEAND RATING230V - 3.15A H115V - 6.3A H THIS PRODUCT MUST BE EARTHED
40-60Hz
5%V
SPEAKER OUTPUTS
MINIMUM LOAD 4OHMSOUTPUT RATING 50W/4OHMS
100V/70V LINEOUTPUTS
CH
1
CH2
CH3
CH4
1
2
1 2
3 4
(OUT)
(IN)(IN)
(OUT)
(IN)
(OUT)
CH1
0V
0V
CH
20
VC
H3
0V
CH
4SOURCESOURCESOURCE
HIGH VOLTAGE
THIS COVERREMOVEDO NOT
OUTPUT
DANGER
LINE100V/70V
REMOTELEVEL
REMOTELEVEL
REMOTELEVEL
REMOTELEVEL
REMOTELEVEL
REMOTELEVEL
REMOTELEVEL
REMOTELEVEL
FUSE
230V - T4A115V - T8A
CH 1 RL-1
1 2 3
1 2 3
1 2 3
RL-1
2 31
1 2 3
RL-1
2 31
1 2 3
RL-1
2 31
1 2 3
RL-1
2 31
1 2 3
RL-1
2 31
1 2 3
RL-1
2 31
1 2 3
RL-1
2 31
CH CH CH CH CH CH CH2 3 4 5 6 7 8
1
2
1 2 3LEVELSOURCE
- - -
2(OUT)
(IN)
(OUT)
1(IN)
3
3
SOURCELEVEL 1 2 3
---
(OUT)
2(IN)
4
4
SOURCELEVEL 1 2 3
---
(OUT)
1(IN)
5
5
SOURCELEVEL 1 2 3
---
(OUT)
2(IN)
6
6
SOURCELEVEL 1 2 3
---
(OUT)
1(IN)
7
7
SOURCELEVEL 1 2 3
---
(OUT)
2(IN)
8
8
SOURCELEVEL 1 2 3
---LEVEL 1 2 3
---
1 SPEAKER OUTPUTSOUTPUT RATING 50W / 4OHMS
MIN LOAD 4 OHMS
0V
CH
10
VC
H2
0V
CH
30
VC
H4
0V
CH
50
VC
H6
0V
CH
70
V
CH
8
POWER INPUT
REPLACE FUSE WITH SAMETYPE AND RATING
THIS UNIT MUST BE EARTHED
5%40-60Hz
CLOUD MULTI-CHANNEL POWER AMPLIFIERS
MODELS CX-A450 & CX-A850
Cloud CX-A450 - rear panel view
Cloud CX-A850 - rear panel view
General Description
C l e a r l y b e t t e r s o u n d
CX-A850 ONLY
Block Diagram
• General purpose, high quality 4 and 8-channel power amplifiers with superior audio performance
• 4 x 50 W (CX-A450) or 8 x 50 W (CX-A850) into 4 ohms• Very low inter-channel crosstalk• Thermal protection• VI limiting• DC offset protection• Dynamic Clipping Protection• Switch-on delay (for speaker protection during power rail
stabilisation)• Pairs of channels may be operated in Bridge Mode • Per-channel, front-panel LEDs for signal presence, peak level
and protection status
• Balanced line level inputs with gain trim• Rear panel switches to configure for multichannel, stereo or
mono operation• Optional internal 4-channel 100 V/70 V transformer module
(CX-A450 only)• Optional externally-mountable 100 V/70 V transformers (per-
channel) • Optional remote volume control (per-channel)• A range of optional per-channel EQ cards, to match various
popular loudspeakers• 2U 19” rackmounting units• Variable speed forced-air cooling• Five year warranty
C l e a r l y b e t t e r s o u n d
Input Routing
The input routing switches of the CX-A450 and CX-A850 permit various permutations of mono, stereo and multi-channel operation without any external parallel wiring. Some possibilities are shown below:
C l e a r l y b e t t e r s o u n d
In another situation, it might be necessary to route the same audio to several different zones, but allow each zone to adjust its own level. This can be easily achieved by providing each zone with a Cloud RL-1 remote volume control plate, and setting the amplifier’s input routing to parallel all the channels. Only a single input feed needs to be supplied, to Channel 1
System Example
CX-A450 and CX-A850 amplifiers’ exceptional crosstalk performance make them particularly suitable for any application where different audio sources need to be routed to various zones (parts of a building). They are equally suitable in a situation where a common audio source needs to be reproduced at different levels in various zones. The flexibility of the amplifiers’ input routing makes it possible to handle a mixture of mono and stereo sources without complex wiring.
In many applications, the power amplifiers will be used in combination with a Cloud Zoner, to permit paging and emergency override. An example is the CX263 zoner, which supports three zones, one of which may be stereo. In the example shown below, where a CX263 is used with a CX-A450, Chs. 1 & 2 are used to drive stereo to Zone 1, while Chs. 3 & 4 are used for the mono signals to Zones 2 and 3 respectively.
Similar mono-stereo arrangements are possible with the Cloud CX163 and Z4II zoners.
C l e a r l y b e t t e r s o u n d
Graphs
Audio Precision 05/31/11 15:06:04CXA450 Frequency Response
ColorSweep Trace Line Style Thick Data Axis Comment
1 1 Blue Solid 2 Anlr.Level A Left CH2 Freq Response Sig=-6dBu
-3
+3
-2
-1
+0
+1
+2
dBr
20 20k50 100 200 500 1k 2k 5k 10kHz
Audio Precision 05/31/11 11:22:06CX-A850 Frequency Response
ColorSweep Trace Line Style Thick Data Axis Comment
1 1 Red Solid 1 Anlr.Ampl Left CH2 Frequency response
-3
+3
-2.5
-2
-1.5
-1
-0.5
+0
+0.5
+1
+1.5
+2
+2.5
dBr
20 20k50 100 200 500 1k 2k 5k 10kHz
Audio Precision 05/31/11 12:21:05CX-A450 Crosstalk
ColorSweep Trace Line Style Thick Data Axis Comment
1 1 Red Solid 1 Anlr.Bandpass Left CH2 to CH1
-100
+0
-80
-60
-40
-20
dBr
20 20k50 100 200 500 1k 2k 5k 10kHz
TT
Audio Precision 05/31/11 13:23:50CX-A850 Crosstalk
ColorSweep Trace Line Style Thick Data Axis Comment
1 1 Red Solid 1 Anlr.Bandpass Left
-100
+0
-80
-60
-40
-20
dBr
20 20k50 100 200 500 1k 2k 5k 10kHz
T
Audio Precision 05/31/11 13:11:59CX-A450 THD+N
ColorSweep Trace Line Style Thick Data Axis Comment
1 1 Red Solid 1 Anlr.THD+N Ratio Left
0.05
0.3
0.1
0.15
0.2
0.25
%
20 20k50 100 200 500 1k 2k 5k 10kHz
T
Audio Precision 05/31/11 13:27:47CX-A850 THD+N
ColorSweep Trace Line Style Thick Data Axis Comment
1 1 Red Solid 1 Anlr.THD+N Ratio Left CH2 THD+N Sig=-10dBu
0.05
0.3
0.1
0.15
0.2
0.25
%
20 20k50 100 200 500 1k 2k 5k 10kHz
T
C l e a r l y b e t t e r s o u n d
Technical Specifications
CX-A450 CX-A850
Performance Output Power (Normal Mode): 50 W/ch into 4 ohms (all chs driven)50 W/ch into 4 ohms (nominal, continuous sinewave)
Output Power (Bridge Mode): 100 W nominal into 8 ohms
Frequency Response: 10 Hz – 20 kHz, +0/-0.5 dB
High Pass Filter: -3 dB @ 65 Hz, switchable per-channel
Distortion: THD+N: <0.02% typical, 1 kHz, 60 W into 4 ohms, one channel driven, 22 Hz – 22 kHz
THD+N: <0.007% typical, 1 kHz, 60 W into 4 ohms, one channel driven, 22 Hz – 22 kHz
Noise: <-96 dB rel. rated output, unweighted, 22 Hz – 22 kHz
Crosstalk: <-70 dB, rel. rated output into 4 ohms, 10 kHz
<-82 dB, rel. rated output into 4 ohms, 10 kHz
VCA module THD+N: <0.03%, 1 kHz, 22 Hz – 80 kHz BW
Inputs Type & connectors Electronically balanced, 3-pin 3.5 mm-pitch screw-terminal connectors
Sensitivity 0 dBu (0.775 Vrms)
Input Impedance 10 kohms (balanced)
General Output Connectors (lo-Z) 2-pin 5 mm-pitch screw-terminal connectors
Output Connectors (100/70 V) Screw terminals
Power input 230 V ±5% (115 V ±5% available)
Mains protection Replaceable fuse, T3.15A H Replaceable fuse, T4A H
Amplifier Protection VI limiting, DC offset, Thermal, Switch-on Delay & Dynamic Clipping Protection
Status Indicators Signal present, Peak & Protection
Cooling Force cooled, variable speed DC fan
Dimensions (W x H x D) 482.6 x 88 (2U) x 300 mm
Weight 7.15 kg 8.8 kg
C l e a r l y b e t t e r s o u n d
E&OEIssue_1.0
The power amplifiers shall be available in four channel and eight channel versions. Either version shall be capable of driving 50 W per channel into a 4 ohm load when all channels are driven simultaneously.
The amplifiers’ front panels shall incorporate an AC power switch, an LED indicating POWER ON, and LEDs indicating Signal Present, Peak Level and Protect status for each channel. The Signal Present LEDs shall illuminate when the output level is 22 dB below the rated output. The Peak LEDs shall illuminate at the onset of signal clipping. The Protect LEDs shall indicate activation of the channel protection circuitry.
The amplifiers shall be provided with one input per channel and be able to operate in the following configurations as a minimum: all channels independent, one input feeding all channels or two inputs feeding the amplifier channels in pairs for stereo operation. Signal level adjustment will be provided for each channel via a rear panel control permitting a range of operation from not less than 90 dB attenuation (min.) to unity gain (max.). The inputs shall be electronically balanced and capable of operating with both balanced and unbalanced sources. The input impedance shall be 10 kohms (balanced). The input connectors shall be of Euroblock type. It shall be possible to enable a high-pass 3rd-order filter with a turnover frequency of 65 Hz independently in each amplifier channel.
Each channel shall deliver its rated power from an input signal of 0 dBu with input level controls set at maximum. Output mute protection on power-up and thermal protection shall be provided. The amplifiers will also be protected against short-circuits at the
output, and excessive combination of output voltage and current. The amplifiers’ outputs shall be on Euroblock connectors.
A range of optional, single-channel transformer modules, and suitable rackmounting housings, shall be available to permit the amplifiers to drive 100 V-line and 70 V-line loudspeaker systems. It shall also be possible to adapt the four channel amplifier version for direct connection to 100 V-line and 70 V-line systems by the addition of an internally-fitted four-channel transformer module.
An optional remote control shall be available for any or all amplifier channels, to allow adjustment of channel gain. The remote control connector shall be of Euroblock type. It shall also be possible to fit optional EQ cards to any or all channels to suit a range of current, popular loudspeaker types.
The amplifier shall be built in a steel chassis suitable for mounting in a standard 19” equipment rack, and occupy two rack spaces. Variable speed forced-air cooling shall be employed.
The amplifier shall be available in versions operating on either 230 V or 115 V AC mains, the intended mains voltage to be specified by the user at the time of order. The power amplifiers shall be the Cloud CX-A450 (four channels) and CX-A850 (eight channels).
Architect’s and Engineer’s Specification