CLiP 3 Dynamic - tempollc.com · CLiP 3 Dynamic Installation 2020-01-06 Page 6 of 6 161 McGaw Ave....
Transcript of CLiP 3 Dynamic - tempollc.com · CLiP 3 Dynamic Installation 2020-01-06 Page 6 of 6 161 McGaw Ave....
CLiP 3 Dynamic Installation 2020-01-06 Page 1 of 6
1961 McGaw Ave. • Irvine, CA 92614 • (949) 442-1601 • tempollc.com
ELECTRICAL RATINGS
Powered by remote low voltage 24VDC system.
HARDWARE PROVIDED
(a) Power Feed Cable (PFC-24V-5-F-xx)
(b) Power Supply (Order Separately)
(c) Mounting Brackets (Order Separately)
OPTIONAL HARDWARE
(d) Jumper Feed Cable (JFC-24V-5-MF-xx)
WARNING:Read and understand these instructions before installing. This product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and the hazards involved. Turn off main power supply before you start installing.
Ratings, Hardware and Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 1Fixture Installation Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 2DMX Driver & Wall Mount Touch Controller Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 3-4DMX Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 50-10V Warm Dim Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 6
b) Power Supplya) Power Feed
d) Jumper Feed
!
CLiP 3 Dynamic • DMX RGB, RGB-WHITE, RGB-AMBER & TUNABLE WHITE. • 0-10V WARM DIM.
c) Mounting Brackets
INSTALLATION INSTRUCTIONS
CLiP 3 Dynamic Installation 2020-01-06 Page 2 of 6
1961 McGaw Ave. • Irvine, CA 92614 • (949) 442-1601 • tempollc.com
STEP 1
Install mounting brackets & attach fixtures:
Mark a line on surface where the edge of fixture will be. Place mounting brackets on edge of marked line and secure with screws provided, Figure 1.
Install fixtures on the mounting brackets by centering the fixture over the bracket and pushing fixture down, snapping fixture into bracket. Figures 2 & 3.
STEP 2
Connecting Power Feed:
Install power supply in approved enclosure in close proximity to luminaire.
Connect the female connector on the Power Feed to the male connector on the fixture by lining up pins & locking tab and pressing female connector into fixture, Figure 4.
Connect the other end of the Power Feed to the output of the corresponding power supply. NOTE: See following wiring diagrams for details as some models do not use all 5 wires.
STEP 3
Connecting fixture to fixture:
Join fixtures together by directly connecting the male and female connectors on the fixture using same method used to connect power feed in Step 2, Figure 5 & 6, or by using the optional Jumper Feed Cable, Figure 7.
Figure 1 Figure 2
FIXTURE INSTALLATION
Figure 4
CLiP 3 DYNAMIC INSTALLATION INSTRUCTIONS
Figure 5
Figure 7
Figure 6
Figure 3
CLiP 3 Dynamic Installation 2020-01-06 Page 3 of 6
1961 McGaw Ave. • Irvine, CA 92614 • (949) 442-1601 • tempollc.com
DRIVER DETAILS
CLiP 3 DYNAMIC INSTALLATION INSTRUCTIONS
9.65”
1.3”
2.6”
DMX LED DRIVER(PWR-UNV-EM-96-DMX)
Dimensions
LED
OU
TP
UT
1/R-
2/G-
3/B-
4/W-
Back Enter Up Down
DM
X51
2IN
PU
T
N
L
INP
UT
100-277VA
C
D+
D-
GND
NC
NC
NC
NC
DMX LED DRIVER96W MAX
100V-277V ACPower Input
Digital Display
DMX512Signal Input
Common Output (+)CH 1: R/WW Output (-)CH 2: G/NW Output (-)Common Output (+)CH 3: B/CW Output (-)CH 4: White Output (-)
Back Enter Up Down
CLiP 3 Dynamic Installation 2020-01-06 Page 4 of 6
1961 McGaw Ave. • Irvine, CA 92614 • (949) 442-1601 • tempollc.com
DMX WALL MOUNT TOUCH CONTROLLER DETAILS
CLiP 3 DYNAMIC INSTALLATION INSTRUCTIONS
Red, Green & Blue channels: Tap to turn o�/on.Press & hold to increase &decrease light intensity.
Scenes 1, 2 & 3: Press and hold to save color.Tap to recall the saved color.
E�ects: Tap to play/pause 10 built-ine�ects. Press & hold to changerunning speed of e�ects.
White channel*: Tap to turn o�/on.Press & hold to increase &decrease light intensity.
Touch color wheel:Touch to select R/G/B
color mix.
Power on/o�
RGB & White Mix*:Tap to select Warm, Natural
or Cool White RGB mixes.
Brightness:Press & hold to increase &
decrease light intensity.
Decrease Brightness:Press & hold to decrease
light intensity.
Touch color wheel:Touch to select color temp.
Cool Channel:Press & hold for cooler white.
Increase Brightness:Press & hold to increaselight intensity.
Zones 1, 2 & 3:Tap to choose zone.Hold down to turn on/o�corresponding zone.
Warm Channel:Press & hold for warmer white.
Power on/o�
Scenes 1, 2 & 3:Press and hold to save scene.Tap to recall the saved scene.
V- D+D-V+ GND
DC INPUT DMX OUTPUT
0.75”
0.4”
1.72”
3.25”2.6”
3.0”
4.75”
Wall Mounted Touch ControllerRGB DMX512
Wall Mounted Touch ControllerTunable White DMX512
Dimensions
*Only works with RGBW �xtures.
CLiP 3 Dynamic Installation 2020-01-06 Page 5 of 6
1961 McGaw Ave. • Irvine, CA 92614 • (949) 442-1601 • tempollc.com
WIRING DIAGRAMS
CLiP 3 DYNAMIC INSTALLATION INSTRUCTIONS
V+ GrayR- RedG- GreenB- BlueW- White (RGB-W & RGB-A only)
LED
OU
TP
UT
1/R-
2/G-
3/B-
4/W-
Back Enter Up Down
DM
X51
2IN
PU
T
N
L
INP
UT
10 0-277VA
C
D+
D-
GND
NC
NC
NC
NC
LED
OU
TP
UT
1/R-
2/G-
3/B-
4/W-
Back Enter Up Down
DM
X51
2IN
PU
T
N
L
INP
UT
100 -2 77VA
C
D+
D-
GND
NC
NC
NC
NC
LED
OU
TP
UT
1/R-
2/G-
3/B-
4/W-
Back Enter Up Down
DM
X51
2IN
PU
T
N
L
INP
UT
100 -2 77VA
C
D+
D-
GND
NC
NC
NC
NC
CLiP 3 Power Feed Cable
CLiP 3
CLiP 3
CLiP 3
120 ohm, 1W Resistor
(Supplied with Driver)
For termination of DMX signal.Only use one Resistor on the last driver in line
when using multiple drivers.
Neutral
Line
Neutral
Line
Neutral
Line
V- D+D-V+ GND
DC INPUT DMX OUTPUT
12VDC Out
SuppliedAC/DC
Adapter
100V-240V AC
100V
-277
V AC
100V
-277
V AC
100V
-277
V AC
Neu
tral
(Blu
e)
Line
(Bro
wn)
DMX LED DRIVER96W MAX
DMX LED DRIVER96W MAX
DMX LED DRIVER96W MAX
CLiP 3 Power Feed Cable
CLiP 3 Power Feed Cable
DMXTouch
Controller(RGB or Tunable White)
Wiring DiagramDMX RGB; RGB-W; RGB-A; TW
Note: White wire from CLiP 3 power feed only usedfor RGB-W and RGB-A. Cap White wire for RGB & TW.
CLiP 3 Dynamic Installation 2020-01-06 Page 6 of 6
1961 McGaw Ave. • Irvine, CA 92614 • (949) 442-1601 • tempollc.com
WIRING DIAGRAMS
CLiP 3 DYNAMIC INSTALLATION INSTRUCTIONS
Line/Hot (Black)
120-270 VAC50/60 Hz Line/Hot (Red)
Red/White
Neutral (White)
DC +
DC -
Line (Black)
Ground(Green)
Purple
Gray
0-10V Control + (Purple)
0-10V Control - (Gray)
To CLiP 3Warm Dim
Fixture
0-10V Dimmer SwitchPDS-010-WM-WH
VIN 1 - (Black)
VIN 2 - (Black)
VIN 2 + (Red)
Cool + (Yellow)
Cool - (Blue)
Warm + (Yellow)
Warm - (Blue)
CLiP 3 Power Feed CablePFC-24V-5-F-36
VIN 1 + (Red)Wam DimControl Module
PCM-010-WD
24VDCPower Supply
Ground(Green)
Wiring Diagram0-10V Warm Dim
Neutral (White)