ClimaGuard Neutral 70 It’s better.€¦ · ClimaGuard Neutral 70 helps you save money and makes...

8
It’s not pyrolytic. It’s better. ClimaGuard ® Neutral 70

Transcript of ClimaGuard Neutral 70 It’s better.€¦ · ClimaGuard Neutral 70 helps you save money and makes...

Page 1: ClimaGuard Neutral 70 It’s better.€¦ · ClimaGuard Neutral 70 helps you save money and makes your home or office a more comfortable place to live or work even in the hot weather

It’s not pyrolytic.It’s better.

ClimaGuard®

Neutral 70

Page 2: ClimaGuard Neutral 70 It’s better.€¦ · ClimaGuard Neutral 70 helps you save money and makes your home or office a more comfortable place to live or work even in the hot weather

Please Note: ClimaGuard Neutral 70 cannot be used monolithically. The coating must be protected within an insulated unit or against the PVB of laminated glass.

Guardian Industries’ SunGuard Series of architectural products combine the aesthetic and performance requirements that are required by building owners and architects. These revolutionary, post-temperable products also provide the durability and fabrication capability required by glass processors. Guardian’s new ClimaGuard Neutral 70 offers a highly durable, easy-to-process, fabricator-friendly low-E coating for both light commercial and residential applications. ClimaGuard Neutral 70 delivers energy efficiency, colour neutrality and it is extremely versatile for busy processors.

BenefitsEasy to fabricate when compared to sputter-coated low-E• Superior mechanical and chemical durability• No edge-deletion required• Single product for both annealed and tempered applications• Extended shelf life for annealed (1 year) and heat-treated (30 days) products• Does not require certification

Superior performance and aesthetics, compared to pyrolytics• Lower haze and reflectivity• Lower U-Value and lower Shading Coefficient

Easy to order• Available with other Guardian products in mixed-load quantities — combine all of your SunGuard high-performance and high-durability low-E from one source

IT’S NOT PYROLITIC. IT’S BETTER!

Shading Coefficient of 0.61 (NFRC 100 - 2004).A 13% performance improvement over most pyrolitics. *ClimaGuard Neutral 70

A low U-Value of 1.47 W/m2K. (.29 BTU/hr.ft2.F) **ClimaGuard Neutral 70

* Comparison unit 6mm / 12mm a.s. / 6mm - low-E on surface #2

** Comparison unit 4mm / 16mm a.s. / 4mm - 90% argon gas filled low-E on surface #3

Page 3: ClimaGuard Neutral 70 It’s better.€¦ · ClimaGuard Neutral 70 helps you save money and makes your home or office a more comfortable place to live or work even in the hot weather

VS. Typical Pyrolytic low-E

Insulating Glass Data

Notes: • Guardian reserves the right to change product performance characteristics without notice or obligation. • The performance values shown are nominal and subject to variations due to manufacturing tolerances. • Guardian performance data are calculated in accordance with the LBNL Window 5.2 computer analysis using an air mass of 1.5. • May require heat strengthening or tempering to resist potential thermal stresses. • Please contact Guardian for assistance.

Characteristic ClimaGuard Neutral 70 Typical Pyrolytic Low-E

Easy Fabrication 3 3

Single Product(annealed & heat-treated)

3 3

No Edge-Deletion Required 3 3

No Certification Required 3 3

Extended Shelf Life 3 3

Colour-Neutral 3 3

Surface #2 or #3 3 3

Lower Haze 3

Lower Reflectance 3

Lower U-Value 3

Lower Shading Coefficient 3

Product

Visible Light Solar EnergyEuropean Standards American standards (NFRC100-2004)

Solar Factor (g)

Shading Coeff.g

DIN/0,87

U-value Nighttime

EN 673W(m2k)

Winter Summer

Trans-mission

%

Reflec-tionout-

side%

Reflec-tion

inside%

Direct Trans-

mission%

Reflec-tionout-

side%

Absorp-tion%

EN410%

DIN67

507%

U-value night time

BTU/hr.ft2.F

U-value Day time

BTU/hr.ft2.F

SHGC

Relative Heat Gain

BTU/hr.ft2

SunGuard® High Performance-3mm clear/12mm a.s./ 3mm clear High Performance Coating #2 SurfaceClimaGuard Neutral 70 69 12 13 54 17 29 59 57 0.65 1.9 0.34 0.35 0.57 135

SunGuard® High Performance-6mm clear/12mm a.s./ 6mm clear High Performance Coating #2 SurfaceClimaGuard Neutral 70 67 12 12 49 15 36 56 54 0.62 1.9 0.34 0.34 0.54 129

SunGuard® High Performance-6mm green/12mm a.s./ 6mm clear High Performance Coating #2 Surface

Green 70 56 10 12 31 8 61 37 36 0.41 1.9 0.34 0.34 0.36 87

SunGuard® High Performance-6mm tinted/12mm a.s./ 6mm clear ClimaGuard Neutral 70 #3 Surface

Green/Clear 57 10 11 31 8 61 43 41 0.47 1.9 0.34 0.34 0.41 99

Grey/Clear 35 6 10 27 9 64 39 38 0.44 1.9 0.34 0.34 0.40 95

Bronze/Clear 40 7 10 29 9 62 42 40 0.47 1.9 0.34 0.34 0.42 101

Page 4: ClimaGuard Neutral 70 It’s better.€¦ · ClimaGuard Neutral 70 helps you save money and makes your home or office a more comfortable place to live or work even in the hot weather

Hot Weather or Cold Weather?

is the answer

HEAT

Hot Weather ClimatesClimaGuard Neutral 70 helps you save money and makes your home or office a more comfortable place to live or work even in the hot weather climates. ClimaGuard Neutral 70 will provide the following benefits over traditional double or single glazed windows. - Reduction in solar energy transmission - Reduction in condensation on the windows - Reduction in transmission of radiant energy ( long wave energy during the daytime or nighttime)

On a summer’s night the temperature outside may be 35°C, on average the temperature inside your home would normally be maintained at around 22°C. Depending on your glazing choice the Relative Heat Gain would be as follows: Single Glazing 242.74 W/m2 *Traditional Double Glazing 122.95 W/m2 **ClimaGuard Neutral 70 Double Glazing 81.97 W/m2 *** 33% better performance than traditional Double Glazing(The lower the Relative Heat Gain number the better the performance)

During the summer daytime hours a great deal of heat is absorbed by the surrounding buildings, pavement, rocks and mountains. During the summer nighttime hours this absorbed heat continues to radiate in the form of long wave energy. ClimaGuard Neutral 70 is specifically designed to minimize the transmission of long wave energy. This is seen in the reduction of Relative Heat Gain. Therefore a significant amount of this heat remains outside while maintaining a comfortable environment inside. Energy costs due to air-conditioning are dramatically reduced compared to traditional double or single glazing. ClimaGuard Neutral 70 will help minimize condensation that is very common in summer nighttime conditions.

Based on comparison units:* 6mm clear gas** 6mm /12mm a.s. / 6mm - air filled clear unit*** 6mm / 12mm a.s. / 6mm - air filled unit, Guardian Neutral 70 on surface #3

Relative Heat Gain (RHG) = total net heat gain to the indoors due to both the air-to-air thermal conductance and the solar heatgain. The units are W/m².

Cold Weather ClimatesClimaGuard Neutral 70 helps you save money and makes your home or office a more comfortable place to live or work. ClimaGuard Neutral 70 will provide the following benefits over traditional double or single glazed windows. - Reduction in heat loss - Reduction in cold spots in the room - Reduction in condensation on the windows - Reduction in down drafts around the windows On a winter’s day the temperature outside may be 0°C, the average temperature inside your home would normally be maintained at around 22°C. Depending on your glazing choice the surface temperature of your glass inside your window would be as followsSingle Glazing 3.2°C *Traditional Double Glazing 12.4°C **ClimaGuard Neutral 70 Double Glazing 16.4°C ***

It is this difference in the surface temperature of the glass that dictates whether you get condensation build up, cold spots in your room near windows, and cold downdrafts caused by your glazing. As you can see, the inner pane temperature of ClimaGuard Neutral 70 outperforms traditional glazing options, therefore maximizing the usable space around windows as well as reducing your energy costs due to heating. Based on comparison units:* 4mm clear gas** 4mm / 12mm a.s. / 4mm - air filled clear unit*** 4mm / 16mm a.s. / 4mm - 90% gas filled unit, Guardian Neutral 70 on surface #3

Inside winter night condition - heat is absorbed and re-radiated back into the room when a low-E coating is incorporated into an I.G. unit

Outside winter night condition

Outside summer night condition - radiant heat is absorbed and re-radiated back into the environment when a low E coating is incorporated into an I.G. unit

Inside summer night conditions

Page 5: ClimaGuard Neutral 70 It’s better.€¦ · ClimaGuard Neutral 70 helps you save money and makes your home or office a more comfortable place to live or work even in the hot weather

InspectionClimaGuard Neutral 70 can be inspected, in reflection, for uniformity of coating by placing it in front of a black, nonreflective background with a diffuse light source located above or behind the inspector. This simulates the viewing condition where a person outside looks at the daytime reflection of an overcast sky in the low-E residential glazing. Inspections should also be performed in transmitted light by placing the glass in front of a white, non-reflective background with a diffuse light source located behind the glass (light board). This simulates daytime viewing of the glass from the outside looking through the glass with white interior blinds or drapes.

ClimaGuard Neutral 70 low-E is a durable, neutral colour low-emissivity coating that is intended for use in insulated or laminated glass applications. This guideline is intended for the proper handling and fabrication of ClimaGuard Neutral 70 low-E glass.

Handling and Fabrication Guide

Surface IdentificationWhen opening incoming packaging, the packing tags will indicate the orientation of the coated surface; however, formal detection using an approved detection method is required. Guardian recommends using a coating detector (such as those offered by EDTM, Inc. in Toledo, Ohio) that does not incorporate metal contacts.

Storage And UnpackingClimaGuard Neutral 70 recommends that glass be unloaded under dry, indoor conditions. If outdoor unloading is required, care should be taken to avoid exposure to rain and snow, and glass should be moved indoors as soon as is practical. Do not mark the coated surface with adhesive labels or wax crayons, and do not drag suction cups or metal objects across the surface. The coating is resistant to damage by such materials, but handling practices that are more aggressive than those used with uncoated glass must be avoided. Case tags should remain with the original packaging and case tag numbers should be traceable to work-in-process, and finished goods. Although the coated surface of ClimaGuard Neutral 70 is resistant to staining and chemical degradation, Guardian’s customer assumes responsibility for as-coated inventory that is held beyond 12 months from the original date of receipt from Guardian. Guardian Neutral 70 should be insulated or laminated within 30 days of heat-treatment.

Page 6: ClimaGuard Neutral 70 It’s better.€¦ · ClimaGuard Neutral 70 helps you save money and makes your home or office a more comfortable place to live or work even in the hot weather

CuttingClimaGuard Neutral 70 should be cut with the coating side up to minimize the risk of scratching or marking of the coating. Cutting wheel pressures will be very similar to those for uncoated glass. When the glass is moved across rollers or over an air-float table, the coated surface should face up to avoid abrasion or rub marks. Special care is advised when metal tape measures, straight edges or cutting bars come into contact with the coated surface, as abrasion or marking may occur. Multi-lite stacking should also be avoided to minimize abrasion or marking of the coated surface. The coating is resistant to damage, but handling practices that are more aggressive than those used with uncoated glass must be avoided.Edge preparation such as seaming or polishing should be done coated side up, as the rotation of the seaming table casters could cause a swirling pattern where the caster touches the coating if it were facing down.

WashingAs with uncoated glass, automatic washing machines using hot water and detergents can be used with ClimaGuard Neutral 70. To avoid abrasion or marking of the coated surface, Guardian recommends that coated products should be washed with the coated surface facing up. When spot cleaning is required, use mild, fast-drying household glass cleaners with a clean, soft cloth. Guardian recommends maintaining detergent wash water tank temperature between 49-60°C (120-140°F) during operation. Razor blades and steel wool must not be used on the low-E coated surface.

Heat-TreatingClimaGuard Neutral 70 is a single-product solution for annealed and heat-treated applications; as such, there is no separate heat-treatable (HT) version of this product. As with all low-E glasses, the coating will reflect some radiant heat and so it will require a somewhat longer furnace cycle to achieve the same uniform temperature as uncoated glass of the same thickness. ClimaGuard Neutral 70 must be heat treated with the coated side up to minimize the risk of scratching or marking of the coating. In testing, ClimaGuard Neutral 70 was successfully heat-treated at furnace settings and cycle times similar to pyrolytic coated low-E glass.

Insulating GlassClimaGuard Neutral 70 is intended for use in insulating glass units, with the coated surface facing the air space. The coating may be placed on either the number 2 surface or the number 3 surface depending on the application requirements. ClimaGuard Neutral 70 should not be used in monolithic or non-sealed applications. It is important to confirm that the glass is effectively cleaned and that full sealant adhesion is developed to the coated surface. ClimaGuard Neutral 70 low-E has been tested, and found compatible, for IG construction, without edge deletion, with a variety of Hot Melt Butyls, Polyisobutylenes, Polysulphides, Urethanes and One and Two Part Silicones. Please contact Guardian to confirm sealant compatibility or for any questions.

Page 7: ClimaGuard Neutral 70 It’s better.€¦ · ClimaGuard Neutral 70 helps you save money and makes your home or office a more comfortable place to live or work even in the hot weather

LaminatingClimaGuard Neutral 70 low-E may be used in embedded (facing the PVB) or exposed (facing the airspace) laminated applications. ClimaGuard Neutral 70 may only be laminated with an exposed coated surface if the final glazing package will be an insulating glass unit with the coated surface facing the air space. The ClimaGuard Neutral 70 low-E coating is not damaged by normal laminating processes. Care should be taken to minimize excess PVB remaining around the edge of the glass prior to autoclaving, as this can be difficult to remove from the coated surface. Do not use razor blades or steel wool to remove deposits from the coated surface. Edge deletion of the coated surface is not required for embedded or exposed laminated configurations of ClimaGuard Neutral 70 that incorporate approved sealant materials. Impact testing on laminated glass should be performed to ensure compliance with safety glazing requirements.

PackingWhen packing ClimaGuard Neutral 70 low-E coated glass for shipping with the coating exposed, it is preferable to use a slot-racking system that prevents glass-to-glass contact. It is acceptable to stack individual lites of ClimaGuard Neutral 70; however, care should be taken to ensure proper interleaving is used to minimize the potential for abrasion to the coated and uncoated surfaces.

Recommended Not Recommended

Foam Pads Newsprint

Cork Pads(static foam against coating)

Silver Saver and Kraft PapersCardboard

Polyfoam Sheets Powder SeparatorsContaining Acid

Lucite Beads Nut Powders

For further information, contact Guardian Industries: +971-7-205-8080, www.guardian.com

Page 8: ClimaGuard Neutral 70 It’s better.€¦ · ClimaGuard Neutral 70 helps you save money and makes your home or office a more comfortable place to live or work even in the hot weather

About Guardian Industries Corp.:Guardian is a diversified global manufacturing company headquartered in Auburn Hills, Michigan, with leading positions in float glass, fabricated glass products, fiberglass insulation and other building materials for commercial, residential and automotive markets. Through its Science & Technology Center, Guardian is at the forefront of innovation, including development of high-performance glass coatings and other advanced products. Guardian, its subsidiaries and affiliates employ 18,000 people and operate facilities throughout North America, Europe, South America, Asia, Africa and the Middle East. Visit www.guardian.com or www.sunguardglass.com. SunGuard and ClimaGuard are registered trademarks of Guardian Industries Corp.To request samples call: +971-7-205-8080