02/01/06 Tyler Pipe/Wade Division • Box 2027 • Tyler, TX 75710-2027• (800) 527-8478 • FAX (888) 879-9233 7-1Cleanouts
WADE
Gasketed ABS plug is furnished as standard, Brass plug-75 is optional
Round or square extra heavy-duty covers available for traffic loads.
Snap lock for adjustable
housing.
Two-piece threaded adjustable housing insures true floor level installation.
Low High Position Position
Ty-Seal hub outlet for No-Hub or SV connection (spigot
outlet and inside caulk available).
Anchor flange.
Vandal-proof screws standard on all nickel-bronze tops; security screws optional.
Exclusive Features
Cleanouts
Suffixes and OptionsTo select a cleanout with a standard plug, SV Ty-Seal hub outlet, 4" size, top to be nickel bronze:
NICKEL BRONZETOP (1)
4"SIZE (4) TY-SEALHUB (TY)
ADJUSTABLECO (600)
6004TY, 1
Non-skid scoriated cover with frame secured to adjustable housing.
Tyler Pipe/Wade Division • Box 2027 • Tyler, TX 75710-2027• (800) 527-8478 • FAX (888) 879-9233 02/01/067-2 Cleanouts
WADECleanoutsInstallation Details
6000NH Spigot Outlet - inserted in SV Ty-Seal Hub. Adjustable floor cleanout installed in typical waterproof floor slab. Adjustable housing provides for variations in floor fill.
6000NH Spigot Outlet - used with No-Hub coupling. Adjustable floor cleanout installed in finished floor. Adjustable housing permits flush-with-floor installation.
6000IC, Z Inside Caulk - used with lead and oakum. Adjustable floor cleanout installed in unfinished floor slab. Adjustable housing with special duty cover is designed for heavy traffic areas.
6000TY Hub Outlet - with gasket, accepts No-Hub and SV pipe. Adjustable floor cleanout is installed in finished floor. Adjustable housing permits flush-with-floor installation.
02/01/06 Tyler Pipe/Wade Division • Box 2027 • Tyler, TX 75710-2027• (800) 527-8478 • FAX (888) 879-9233 7-3Cleanouts
WADECleanout TopsOptional Tops
HEAVY-DUTY TOP(X) ROUND
(XS) SQUAREAdds 3/8" To Min. and Max. Vertical Adjustment
ANSI Load Class - Heavy Duty (5,000 to 7,499 lbs.)
TERRAZZO TOP(U) ROUND
(US) SQUAREAdds 3/8" To Min. and Max. Vertical AdjustmentANSI Load Class - Light Duty (Under 2,000 lbs.)
SYNTHETIC COVERING(D)
Adds 3/8" To Min. and Max. Vertical AdjustmentANSI Load Class - Heavy Duty (5,000 to 7,499 lbs.)
TILE TOP (T) ROUND (TS) SQUARE
Adds 3/8" To Min. and Max. Vertical AdjustmentANSI Load Class - Light Duty (Under 2,000 lbs.)
CARPET FLANGE(CF)
ANSI Load Class - Light Duty (Under 2,000 lbs.)
CARPET MARKER(CM)
Cleanout Selection 1. Select the type of ferrule required. 2. Select the adjustable top assembly required for the type of floor and traffic conditions. A. If the Standard Round Top is desired, specify the entire cleanout using the ferrule size and type.
Example: 6004NH, 1. B. To specify any top other than Standard Round, add the letter designation of the top to the ferrule
assembly required. Example: A 6004IC ferrule with a Type Z top should be specified as 6004Z, IC. NOTE: Cleanouts for finished floor areas should be specified with nickel bronze tops. For unfinished
floors or exterior use, specify cast iron tops.
Tyler Pipe/Wade Division • Box 2027 • Tyler, TX 75710-2027• (800) 527-8478 • FAX (888) 879-9233 02/01/067-4 Cleanouts
WADEThe following excerpts from the National Plumbing Code concerning minimum cleanout requirements are listed for reference, but clarification and enlargement in specifications is recommended.
Location: Cleanouts shall be not more than fifty feet apart in horizontal drainage lines of four inch nominal diameter or less, and not more than 100 feet apart for larger pipes.
Change of direction: Cleanouts shall be installed at each change of direction of the building drain greater than 45°.
Base of stacks: A cleanout shall be provided at or near the foot of each vertical waste or soil stack. For buildings with a floor slab on fill or ground, or with less than 18- inch crawl space under the floor, the following will be acceptable instead of a cleanout at the base of the stack. The building drain may be extended to the outside of the building and terminated in an accessible cleanout, or an accessible cleanout installed in the building drain downstream from the stack not more than five feet outside the building wall.
Underground drainage: Cleanouts, when installed on an underground drain, shall be extended to or above the finished grade level directly above the place where the cleanout is installed.
Concealed piping: Cleanouts on concealed piping shall be extended through and terminate flush with the finished wall or floor.
Size of Cleanouts
Small pipes: Cleanouts shall be
of the same nominal size as the pipes up to four inches, and not less than four inches for larger piping.
Large pipes: For underground piping over ten inches, manholes shall be provided and located at each 90° change in direction, and at intervals of not more than 150 feet.
Cleanout Clearances
Small pipes: Cleanouts smaller than three inches shall be installed with a 12-inch clearance for rodding.
Large Pipes: Cleanouts on three inch or larger pipes shall be installed with a clearance of not less than 18- inches for rodding.
Caulking: Cement, plaster or any other permanent finishing material shall not be placed over a cleanout plug.
Concealment: Where it is necessary to conceal a cleanout plug, a covering plate or access door shall be provided which will permit ready access to the plug.
The above excerpts cover only minimum requirements.
For improved cleanout installations the following suggestions are submitted.
Unfinished floor areas: Floor cleanouts shall have a cast iron
Minimum Cleanout Requirements
cover and be designed sufficiently strong for the traffic expected.
Finished floor areas: Consideration should be give to the type and pattern of the finished floor area. Round cleanout covers are recommended for terrazzo floor and square covers for tile floors. Non-ferrous covers and frames of nickel bronze should be used to give the floor area a finished appearance.
Finished walls: Cleanouts in or behind walls should have an access cover and frame embedded flush with the finished wall. The cover shall be smooth nickel bronze of ample size to provide a clear access to the cleanout.
Vandalism: Access and cleanout cover should be secured with vandal-proof screws where these units are accessible and apt to be removed.
02/01/06 Tyler Pipe/Wade Division • Box 2027 • Tyler, TX 75710-2027• (800) 527-8478 • FAX (888) 879-9233 7-5Cleanouts
WADE6000 (SV Hub Outlet, Spigot Outlet) Cast iron cleanout with threaded adjustable housing, flanged ferrule
and round secured nickel bronze top. ANSI Load Class (Standard Top) Light Duty (Under 2,000 lbs)
Floor Cleanouts
Cat. Pipe Wt. No. Size B Lbs.
6002,1 2 2 1/2 16 6003,1 3 2 3/4 17 6004,1 4 3 18 6005,1 5 3 19 6006,1 6 3 21
TOP VARIATIONS Suffix Description ANSI Load Class
CF .. Carpet Flange ........ (LD) CM .. Carpet Marker D ..... Wide Flange .......... (HD) S ...... Standard Square Top .... T ...... Tile Top .................. (LD) TS .... Square Tile Top ..... (LD) U ..... Terrazzo ................. (LD) US ... Square Terrazzo ..... (LD) X ...... Heavy Duty Top XS .... Square Heavy Duty Top
OPTIONS Suffix Description
39 ........ Galvanized Iron Parts 75 ........ Bronze Plug 153 ...... 304 S/S Top 179 ...... Security Screws
OUTLET Suffix Description
TY ....Ty-Seal NH ..No-Hub IC .... Inside Caulk (2", 3", 4")
Tyler Pipe/Wade Division • Box 2027 • Tyler, TX 75710-2027• (800) 527-8478 • FAX (888) 879-9233 02/01/067-6 Cleanouts
WADE6000Z (Spigot Outlet, SV Hub Outlet) Cast iron cleanout with threaded adjustable
housing, flanged ferrule with round scoriated cast iron or with nickel bronze veneer tractor type cover.
ANSI Load Class - Special Duty (Over 10,000 lbs)
Floor Cleanouts
Cat. Pipe Wt. No. Size B Lbs.
6002Z 2 2 1/2 16 6003Z 3 2 3/4 17 6004Z 4 3 18 6005Z 5 3 19 6006Z 6 3 21
OPTIONS Suffix Description
1 .......... Nickel Bronze Veneer 39 ........ Galvanized Iron Parts 75 ........ Bronze Plug 179 ...... Security Screws
OUTLET Suffix Description
TY ....Ty-Seal NH ..No-Hub IC .... Inside Caulk (2", 3", 4")
02/01/06 Tyler Pipe/Wade Division • Box 2027 • Tyler, TX 75710-2027• (800) 527-8478 • FAX (888) 879-9233 7-7Cleanouts
WADE6000 (Spigot Outlet, SV Hub Outlet) Cast iron cleanout with flanged ferrule .
Cleanout Ferrules
OUTLET Suffix Description
TY ........ Ty-Seal NH ...... No-Hub IC ........ Inside Caulk (2", 3", 4")
OPTIONS Suffix Description
39 ........ Galvanized Iron Parts 75 ........ Bronze Plug
Cat. Pipe Wt. No. Size B Lbs.
6002 2 2 1/2 16 6003 3 2 3/4 17 6004 4 3 18 6005 5 3 19 6006 6 3 21
Tyler Pipe/Wade Division • Box 2027 • Tyler, TX 75710-2027• (800) 527-8478 • FAX (888) 879-9233 02/01/067-8 Cleanouts
WADEFloor Cleanouts8000 Cast iron cleanout with threaded adjustable housing, removable
thread shield, plastic gasketed plug and round secured nickelbronze scorated top.
Cat. Pipe Wt. No. Size Lbs.
8002 2 16.0 8003 3 17.0
OPTIONS Suffix Description
75 ........... Bronze Plug 179 ......... Security Screws
OUTLETS Suffix Description
NH ......... No-Hub TY ........... Ty-Seal (Push-On)
8004 4 18.0
02/01/06 Tyler Pipe/Wade Division • Box 2027 • Tyler, TX 75710-2027• (800) 527-8478 • FAX (888) 879-9233 7-9Cleanouts
WADEFloor Cleanouts8000Z Cast iron cleanout with threaded adjustable housing,
removable thread shield, plastic gasketed plug and round ductile iron cover w/ secured nickel bronze scoriated veneer top.
Cat. Pipe Wt. No. Size Lbs.
8002 2 16.0 8003 3 17.0 8004 4 18.0
OPTIONS Suffix Description
75 ........... Bronze Plug 179 ......... Security Screws
OUTLETS Suffix Description
NH ......... No-Hub TY ........... Ty-Seal (Push-On)
Tyler Pipe/Wade Division • Box 2027 • Tyler, TX 75710-2027• (800) 527-8478 • FAX (888) 879-9233 02/01/067-10 Cleanouts
WADENon-Adjustable Floor Cleanout8200 Painted cast iron floor cleanout with flange, round scoriated satin
finish nickel bronze secured cover and frame, gas and watertight brass plug with neoprene seal and bottom outlet.
ANSI Load Class - L.D. = Light Duty (Under 2,000 Lbs.)
Cat. Pipe Wt. No. Size Lbs.
8202 2 5.3 8203 3 8.0 8204 4 11.0
OUTLETS Suffix Description
NH ......... No-Hub TY ........... Ty-Seal
OPTIONS Suffix Description
39 ........... Galvanized Iron Parts 72 ........... Carpet Marker 118 ......... Bronze Plug
63/4
61/4
57/8
621/32
02/01/06 Tyler Pipe/Wade Division • Box 2027 • Tyler, TX 75710-2027• (800) 527-8478 • FAX (888) 879-9233 7-11Cleanouts
WADENon-Adjustable Floor Cleanout8200-Z Painted cast iron floor cleanout with flange, round scoriated ductile
iron secured cover, gas and watertight brass plug with neoprene seal and bottom outlet.
ANSI Load Class - S.D. = Special Duty (Over 10,000 Lbs.)
Cat. Pipe Wt. No. Size Lbs.
8202-Z 2 5.3 8203-Z 3 8.0 8204-Z 4 11.0
OUTLETS Suffix Description
NH ......... No-Hub TY ........... Ty-Seal
OPTIONS Suffix Description
1 ............. Satin Finish Nickel Bronze Veneer Top 39 ........... Galvanized Iron Parts 72 ........... Carpet Marker 118 ......... Bronze Plug
71/16
615/16
57/8
621/38
Tyler Pipe/Wade Division • Box 2027 • Tyler, TX 75710-2027• (800) 527-8478 • FAX (888) 879-9233 02/01/067-12 Cleanouts
WADEAccess Covers8300C Round scoriated vandal proof nickel bronze access cover and
frame. ANSI Load Class - Light Duty (under 2,000 lbs.)
Cat. Wt. No. B C D Lbs.
8300C6 6 5 1/2 4 1/2 3 8300C7 7 1/4 6 3/4 5 3/4 4 8300C10 10 9 1/2 9 7
OPTIONS Suffix Description
179 ......... Security Screws
02/01/06 Tyler Pipe/Wade Division • Box 2027 • Tyler, TX 75710-2027• (800) 527-8478 • FAX (888) 879-9233 7-13Cleanouts
WADEAccess Housing8300MF Access housing with adjustable anchor flange and extra heavy
secured scoriated ductile iron cover. ANSI Load Class - Special Duty (Over 10,000 lbs.)
Cat. Wt. No. Lbs.
8300MF 35
OPTIONS Suffix Description
39 ........... Galvanized Iron Parts 179 ......... Security Screws
Tyler Pipe/Wade Division • Box 2027 • Tyler, TX 75710-2027• (800) 527-8478 • FAX (888) 879-9233 02/01/067-14 Cleanouts
WADEAccess Covers8300S Square 9x9-in.
scoriated secured nickel bronze access cover and frame.
ANSI Load Class - Light Duty (under 2,000 lbs.)
Cat. Wt. No. Lbs.
8300-S9 6
OPTIONS Suffix Description
179 ......... Security Screws
02/01/06 Tyler Pipe/Wade Division • Box 2027 • Tyler, TX 75710-2027• (800) 527-8478 • FAX (888) 879-9233 7-15Cleanouts
WADEWall Access Covers8300SH Square 8 3/4 x8 3/4 "
scoriated nickel bronze hinged secured cover and frame.
Cat. Wt. No. Lbs.
8300SH8 7
OPTIONS Suffix Description
179 ......... Security Screws
Tyler Pipe/Wade Division • Box 2027 • Tyler, TX 75710-2027• (800) 527-8478 • FAX (888) 879-9233 02/01/067-16 Cleanouts
WADEFloor Access Housing8400 Painted cast iron floor access housing with flange, round scoriated
satin finish nickel bronze secured cover and frame and adjusting thumb screws.
ANSI Load Class - L.D. = Light Duty (Under 2,000 Lbs.)
Cat. Pipe Wt. No. Size Lbs.
8402 2 5.3 8403 3 8.0 8404 4 11.0
OPTIONS Suffix Description
39 .......... Galvanized Iron Parts 72 ........... Carpet Marker 179 ......... Security Screws
WADE
PIPE
02/01/06 Tyler Pipe/Wade Division • Box 2027 • Tyler, TX 75710-2027• (800) 527-8478 • FAX (888) 879-9233 7-17Cleanouts
WADEFloor Access Housing8400-Z Painted cast iron floor access housing with flange, round scoriated
ductile iron secured cover and adjusting thumb screws. ANSI Load Class - S.D. = Special Duty (Over 10,000 Lbs.)
OPTIONS Suffix Description
1 ............. Satin Finish Nickel Bronze Veneer Top
39 .......... Galvanized Iron Parts 72 ........... Carpet Marker 179 ......... Security Screws
Cat. Pipe Wt. No. Size Lbs.
8402-Z 2 5.3 8403-Z 3 8.0 8404-Z 4 11.0
Tyler Pipe/Wade Division • Box 2027 • Tyler, TX 75710-2027• (800) 527-8478 • FAX (888) 879-9233 02/01/067-18 Cleanouts
WADE8480C Round smooth nickel bronze secured
access cover with frame.
Wall Access Covers
Cat. Wt. No. B C D Lbs.
8480C6 6 5 1/2 4 1/2 3 8480C7 7 1/4 6 3/4 5 3/4 4 8480C10 10 9 3/4 9 7
OPTIONS Suffix Description
179 ......... Security Screws
02/01/06 Tyler Pipe/Wade Division • Box 2027 • Tyler, TX 75710-2027• (800) 527-8478 • FAX (888) 879-9233 7-19Cleanouts
WADE8480R Round stainless steel access cover with 1/4 -20x3 1/2
center screw.
Wall Access Covers
Cat. Plug Wt. No. C Size Lbs.
8480R6 6 1 1/2 to 3 1/2 1/2
8480R8 8 4, 5 and 6 3/4
8480R10 10 8 3/4
Tyler Pipe/Wade Division • Box 2027 • Tyler, TX 75710-2027• (800) 527-8478 • FAX (888) 879-9233 02/01/067-20 Cleanouts
WADE8480S Square nickel bronze frame with secured
smooth stainless steel access cover.
Wall Access Covers
Cat. Wt. No. Lbs.
8480S 2.5
OPTIONS Suffix Description
179 ......... Security Screws
02/01/06 Tyler Pipe/Wade Division • Box 2027 • Tyler, TX 75710-2027• (800) 527-8478 • FAX (888) 879-9233 7-21Cleanouts
WADE8480-ST Square wall access panel with satin finish nickel bronze
frame and secured smooth finish stainless steel cover.
Access Panel
Cat. Wt. No. Lbs.
8480-ST 3.0
OPTIONS Suffix Description
179 ......... Security Screws
7" SQUARE
38
316
114
316 [4.76]
10-24NC(4 PLACES)
716
814
814
658
658
916
1 516
7" SQUARE7" SQUARE7" SQUARE7" SQUARE
33338888
333316161616
111111114444
333316161616 [4.76][4.76][4.76][4.76]6666
10-24NC10-24NC10-24NC10-24NC(4 PLACES)(4 PLACES)(4 PLACES)(4 PLACES)
777716161616
888811114444
888811114444
666655558888
666655558888
999916161616
1111 555516161616
Tyler Pipe/Wade Division • Box 2027 • Tyler, TX 75710-2027• (800) 527-8478 • FAX (888) 879-9233 02/01/067-22 Cleanouts
WADE8480X Round smooth finish nickel bronze dished access
cover with 1/4 -20x3 1/2" long center screw.
Access Covers
Cat. Wt. No. Lbs.
8480X6 4
02/01/06 Tyler Pipe/Wade Division • Box 2027 • Tyler, TX 75710-2027• (800) 527-8478 • FAX (888) 879-9233 7-23Cleanouts
WADE8550 (B orE) Cast Iron cleanout ferrule
with spigot outlet and threaded brass raised head, or countersunk plug drilled and tapped for 1/4 -20 screw.
Cleanout Ferrule w/ Plug
Cat. Pipe Plug Wt. No. Size A Size Lbs.
8552 2 2 3/4 1 1/2 1.5 8553 3 3 2 1/2 2.5 8554 4 3 1/4 3 1/2 4 8555 5 4 1/2 4 6 8556 6 4 1/2 5 9
PLUG TYPE Suffix Description
B ............. Raised Head Brass Plug E ............. Countersunk Brass Plug
Tyler Pipe/Wade Division • Box 2027 • Tyler, TX 75710-2027• (800) 527-8478 • FAX (888) 879-9233 02/01/067-24 Cleanouts
WADE8560 (B orE) Cast Iron cleanout tee with spigot inlet/outlet and
threaded brass raised head, or countersunk plug drilled and tapped for 1/4 -20 screw.
Cleanout Tee w/ Plug
Cat. Pipe C Wt. No. Size B Plug D E Lbs.
8562 2 6 3/8 2 2 3 3/16 2.7 8563 3 7 3/4 3 2 3/4 3 7/8 4.8 8564 4 8 7/8 4 3 4 7/16 9.4 8565 5 11 1/2 5 4 1/2 5 3/4 14.7 8566* 6 12 1/2 6 5 6 1/4 18.4
* Type E Plug Only
PLUG TYPE Suffix Description
B ....... Raised Head Brass Plug E ....... Countersunk Brass Plug
02/01/06 Tyler Pipe/Wade Division • Box 2027 • Tyler, TX 75710-2027• (800) 527-8478 • FAX (888) 879-9233 7-25Cleanouts
WADECleanout Tee w/ Plug8570 (B or E) Painted cleanout tee with hub inlet / spigot outlet and bronze
NPT threaded plug drilled & tapped for 1/4-20NC screw.
Cat. Pipe Plug Wt. No. Size Size A B C Lbs.
8572 2 2 10 3/8 7 7/8 4 1/4 6.3 8573 3 3 12 3/4 10 5 1/2 10.7 8574 4 4 13 7/8 10 7/8 6 15.0 8575 5 5 15 12 7 1/8 23.3 8576 6 6 16 12 7 1/8 28.3 8578 8 8 20 1/2 17 7 53.5
PLUG TYPE Suffix Description
B ....... Raised Head Brass Plug
E ....... Countersunk Brass Plug
39 ..... Galvanized Iron Parts
Tyler Pipe/Wade Division • Box 2027 • Tyler, TX 75710-2027• (800) 527-8478 • FAX (888) 879-9233 02/01/067-26 Cleanouts
WADECleanout Plugs8590 (B orE) Threaded brass raised head, or countersunk plug drilled and
tapped for 1/4 -20 screw.
Cat. Plug Wt. No. Size Lbs.
8591 1/2 1 1/2 .25 8592 2 .25 8593 3 .50 8593 1/2 3 1/2 .50 8594 4 .75 8595 5 1.00 8596 6 2.00
PLUG TYPE Suffix Description
B ....... Raised Head Brass Plug (Not Available 6")
E ....... Countersunk Brass Plug