CLAS12 Micromegas Tracker:

FE electronics

[email protected]

Page 2: CLAS12 Micromegas Tracker: FE electronics eric.delagnes@cea.fr

2E. Delagnes Saclay Dec 3rd 2009.

Introduction:

•Nearly no work made on the FEE since the May review.•50% of the slides already shown.•Real work cannot start before March 2010.•Preliminary study for compatibility with SVT.

•Outline:–Main Specification for the MicromégasTracker FE chip.–VFE expected performances (starting from AFTER ones).–Selected Architecture.–MTFEC for SVT ?–Plans.

Page 3: CLAS12 Micromegas Tracker: FE electronics eric.delagnes@cea.fr

3E. Delagnes Saclay Dec 3rd 2009.

Features common to all FE solutions: Technology choices

•Technology choices:

– Use an existing chip: there are not a lot of available tracker chip adapted to both analog readout and large detector capacitances:

the APV0.25 designed for CMS could be an option (under evaluation):+ nearly a perfect chip+ we already use it.- APV availability- APV not designed for high detector capacitance.- Large occupation time (RC-CR shaping).

– New chip:• Using a well known technology (AMS CMOS 0.35µm):

+ very front-end part nearly already designed.- Chip size if integrates a lot of digital electronics.

• Using a more recent technology:+ long term availability.+ prepare the future for our lab.+ Less power consumption+? Less noisy.- more risky and longer development .

Page 4: CLAS12 Micromegas Tracker: FE electronics eric.delagnes@cea.fr

4E. Delagnes Saclay Dec 3rd 2009.

Features common to all FE Chip solutions

•Packaging, modularity:

– For Mmegas Prefer a QFN/QFP package (no bare die).

– 32-64 channel/chip is the best modularity for integration on FE boards.

– 128 channel/chip => big chip + package difficult to handle during test.

•Power consumption

– As we are outside the magnet, the requirements can be relaxed/ ~5 mW/ch for the FE Chip.

•Configuration (Slow-control) Link:

– To program test modes, peaking time, ranges, etc.

•Test system:

– Each Channel can be pulsed individually (or all together).

– For test purpose and not absolute calibration.

•Input Protections:

– Designed to reduce the size (or even the need) of the external protections.

Page 5: CLAS12 Micromegas Tracker: FE electronics eric.delagnes@cea.fr

5E. Delagnes Saclay Dec 3rd 2009.

Requirements for the CLAS12 MM electronics (1).

•For the moment only the barrel has been studied•Use of standard (without resistive sheet) Micromegas assumed•~20000 channels•Electronics moved away from detector using 0.8m Kapton cables•Particle rate < 20MHz

» Hit Rate=> 48 kHz/strip (considering cluster size=4)•External trigger with Max Trigger Rate = 20 kHz, fixed latency =4.5µs•Inefficiency due to electronics ~ 2%•Ghost hits/trigger < 8/view. Noise hits rate negligible•Main functionalities (not necessary performed in this order):

– Collect, amplify and filter the detector signal– Discriminate pulses– Timestamp pulses– Select pulses within a L1W ( = 100ns) window around the L1

accept signal– Measure signal charge (for centre of gravity calculation)

•Many requirements very similar to those of COMPASS tracker

Page 6: CLAS12 Micromegas Tracker: FE electronics eric.delagnes@cea.fr

6E. Delagnes Saclay Dec 3rd 2009.

Requirements for the CLAS12 Micromegas electronics (2).

•Channel Occupancy:– Tocc <250ns to keep occupancy < 1.2%– High order filtering (symmetrical shape).

•Shaping peaking time must be– Large:

• To avoid ballistic deficit .• To Minimize noise.

– Small:• to limit occupancy• to be Compatible with L1W=100ns

From calculations and experience from

COMPASS:~100ns peaking time

should be ok => Tunable between 50-250ns.

Page 7: CLAS12 Micromegas Tracker: FE electronics eric.delagnes@cea.fr

7E. Delagnes Saclay Dec 3rd 2009.

Requirements for the CLAS12 Micromegas electronics (3).

•Dynamic Range:– 600: 9-10 bit Max Signal over ENC required.

- Max Charge = 10 MIP- Threshold = MIP/10 for efficiency- Threshold = 6 * Thresholds set to 6*ENC (for noise rejection).

– Max range (and MIP) depends on the detector gain => Variable gain front-end: 4 ranges selectable by slow control:

• i.e 160, 320, 640 fC for Micromegas.• ~ 40 fC range for Si detectors.

Exemple:For the160fC range:

=> MIP = 100 Ke-=> Th = 10 Ke –=> ENC should be around 1500 e- rms (gives a S/N=60)

Feasible with our large detectors (+ kapton cables) ?

Page 8: CLAS12 Micromegas Tracker: FE electronics eric.delagnes@cea.fr

8E. Delagnes Saclay Dec 3rd 2009.

What we can learn from the AFTER chip

– AMS 0.35µm technology.

– Designed for the TPC of T2K.

– Slow Readout (incompatible with use in trackers)

– But very versatile: • shaping time, dynamic range are ~matching with our needs.

– Front-end part could be re-used nearly as it is associated with a custom back-end.

– Modifications (50ns shaping) in progress for another experiment.

– Noise deeply tested: a complete parameterization has been extracted: Ability to predict the noise in other conditions.

– 1Mrad radiation hardness demonstrated in another similar chip we designed using the same technology.

Page 9: CLAS12 Micromegas Tracker: FE electronics eric.delagnes@cea.fr

9E. Delagnes Saclay Dec 3rd 2009.

AFTER ASIC design for T2K

Main features:Main features:•Input Current Polarity:Input Current Polarity: positive positive oror negative negative•7272 Analog Channels Analog Channels•44 Gains: 120fC, 240fC, 360fC & 600fC Gains: 120fC, 240fC, 360fC & 600fC •1616 Peaking Time values: (100ns to 2µs) Peaking Time values: (100ns to 2µs)•511 analog memory cells / Channel:511 analog memory cells / Channel:

Fwrite: 1MHz-50MHz; Fread: 20MHzFwrite: 1MHz-50MHz; Fread: 20MHz

AFTER

511 cells

SCAFILTER

100ns<tpeak<2us

CSA

1 channel

x72(76)

76 to 1

BUFFER

SCA MANAGERSLOW CONTROL

Serial Interface

W / R

Mode

CK

CK

ADC

TEST

In Test

120fC<Cf<600fC

Power Supply Reference Voltage Reference Current

Asic Spy Mode

CSA;CR;SCAin (N°1)

Power

On Rese

t

•Optimized for 20-30pF detector capaOptimized for 20-30pF detector capa•12-bit dynamic range12-bit dynamic range•Slow ControlSlow Control•Power on resetPower on reset•Test modesTest modes•Spy mode on channel 1: Spy mode on channel 1:

CSA, CR or filter outCSA, CR or filter out

No zero suppress. No auto triggering. No selective readout.

IEEE Trans. Nucl Sci, June 2008

AMS 0.35µm techno500000 transistors

Page 10: CLAS12 Micromegas Tracker: FE electronics eric.delagnes@cea.fr

10E. Delagnes Saclay Dec 3rd 2009.

Requirements for the CLAS12 Micromegas electronics (3).

•Noise:

– Must be minimized to be able to operate at low gain (if necessary to reduce spark rate).

– Huge Flex + detector capacitance of 60-80 pF.

– 1600-2000 ENC (for very low gain operation) seems feasible even with short shaping time:

• From COMPASS experience.

• From measurements on the AFTER chip.

ENC versus input capacitance for different peaking times

(120 fC range, ICSA=400 µA). Measured on the AFTER chip.

Page 11: CLAS12 Micromegas Tracker: FE electronics eric.delagnes@cea.fr

11E. Delagnes Saclay Dec 3rd 2009.

VFE part of the Chip: ~ same as for AFTER

Page 12: CLAS12 Micromegas Tracker: FE electronics eric.delagnes@cea.fr

12E. Delagnes Saclay Dec 3rd 2009.

3 possible options for the FE chip architecture were proposed

ONLY DEAD TIME-”FREE” solutions (with dual-port L1 buffers) are proposed

•ASD + multihit TDC:

- Similar to Micromegas COMPASS tracker readout.

•Time Stamping + analog memory:

• Trigerless Front-end.

• Selective Readout.

•Analog Memory L1-Buffer (APV-like):

– Similar to GEM COMPASS tracker readout.

– Solution selected:

• Better noise rejection.

• Minimum work for us : the only which could match with the schedule and the available manpower.

Page 13: CLAS12 Micromegas Tracker: FE electronics eric.delagnes@cea.fr

13E. Delagnes Saclay Dec 3rd 2009.

Analog Memory L1 buffer solution (APV-like solution)

•A Switched Capacitor Array is used as a circular analogue buffer:

•The analog signals of all the channels is continuously sampled at Fs in a Switched Capacitor Array (analogue memories).

•When a L1-Trigger occurs it is sent to the chips with a FIXED LATENCY (TLAT):

•3-4 samples on all channels are kept (frozen) for each triggered event.•They are read and multiplexed towards an external ADC @ Fread.

•Cells are rewritten after readout or if no trigger occurs during after TLAT.

•Dead Time “Free” architecture:–No interruption of writing during readout of a triggered event.– several triggered events can be stored in the SCA waiting for readout.

•No on-chip zero suppress: all channels are read for a trigger.

c0c511

c510

ci-2c1 c.

cici-1

ci+1

ci+2

EventEventTriggerTrigger

Write pointer

Read Pointer

Triggeredcells

Page 14: CLAS12 Micromegas Tracker: FE electronics eric.delagnes@cea.fr

14E. Delagnes Saclay Dec 3rd 2009.

SCA: Key parameters

Fs> 2/Tp (2 samples in the trailing edge)

=> Fs = 20 MHz for Tpeak =100ns

SCA DEPTH = Latency + buffer + extra cells

–8 µs latency => 160 cells.

–10 events derandomizing buffer => 40 cells

SCA depth = 256

512 cells is feasible but increase cost

Page 15: CLAS12 Micromegas Tracker: FE electronics eric.delagnes@cea.fr

15E. Delagnes Saclay Dec 3rd 2009.

Main advantages of this solution

•Charge is directly measured.

•Oscilloscope-like operation makes diagnostics easier.

•The timing can be accurately calculated from the samples:– better than 1/Fs precision: In ATLAS LARG ECAL 1ns rms timing

performed with FS=40 MHz (and tp=50ns)

•Pile-up can be detected and even compensated.

•Common mode noise can be calculated and subtracted.

•Low frequency noise can be partially eliminated (by subtracting baseline samples).

•Operations are performed before zero-suppress (discrimination)

Page 16: CLAS12 Micromegas Tracker: FE electronics eric.delagnes@cea.fr

16E. Delagnes Saclay Dec 3rd 2009.

Analog sampling solution (APV-like solution)

•Data flow for the whole MM tracker~ 1600 MByte/s @ the ADC output.•Becomes 20 MByte/s after zero suppress.•Can be reduced by 3 if an online filtering on timing is performed.•For:

– Simple & Proven– Very robust to bad grounding & pickup (common mode node

correction)– Expertise of Saclay on SCAs

•Against:– Need for high frequency ADC & FPGAs close to the very front-

end.– Not self triggered– Need for a L1accept “fast” and synchronous.

FE CHIP

L1 Accept

ADCCommon mode Noise extract +

subtraction

ZeroSuppress

TimingExtraction

+ filter

Page 17: CLAS12 Micromegas Tracker: FE electronics eric.delagnes@cea.fr

17E. Delagnes Saclay Dec 3rd 2009.

Use of the Micromégas chip with SVT ?

•Possible issues:

–Input DC current limited to 5nA. Can be a problem with DC coupled Si detectors:

•AC or DC coupled ?

•Increasing DC current capabilities under study.

–Power consumption:

•5mW/ch planned for MM readout => cooling issue.

•Low power mode for Silicon detectors ?

•Can we move away the electronics (as for MM) ?

–Noise:

•Preliminary study made using:

–AFTER parameterization.

–Data from the “ENC calculations for Barrel Modules of the SVT  “ Note assuming there is a mistake in the leakage current specification (20nA/ch inst. of 5uA/ch).

•A note (+excell file) will be available soon.

Page 18: CLAS12 Micromegas Tracker: FE electronics eric.delagnes@cea.fr

18E. Delagnes Saclay Dec 3rd 2009.

Few words about the noise:

•Expressed as Equivalent Nose Charge => input refered noise.

•Several sources, adding quadratically,can be categorized

–Parallel noise: current noise at chip input. Scales as tp1/2

–Serie noise: voltage noise at chip input. Scales as Cdet and tp-1/2

–1/f noise: 1/f noise of preamp: Scales as Cdet. Constant with tp.

–2nd stage noise : constant.

Analytical model takes into acount these noise sources.Parameters come from:

•Measurements on AFTER•Simulation•Theory

Page 19: CLAS12 Micromegas Tracker: FE electronics eric.delagnes@cea.fr

19E. Delagnes Saclay Dec 3rd 2009.

ENC Model

22

2/1

222ndstagefPARSERIETOTAL ENCENCENCENCENC

2det

22det0

22

2 .)).((( CenCCIenT

IsENC eqRsbiaschip

pSERIE

22det

222RPchipPAR inininTpIpENC

2det0

22/1 )( CCIfENC f

In red: Chip Parameters: (extracted from measurements)In blue: detector parameters (calculated from theory)Tp: « free parameter »

Page 20: CLAS12 Micromegas Tracker: FE electronics eric.delagnes@cea.fr

20E. Delagnes Saclay Dec 3rd 2009.

AFTER: measurement compared to model

Measurements (Ibias=400µA) Analytical model (Ibias=400µA)

Page 21: CLAS12 Micromegas Tracker: FE electronics eric.delagnes@cea.fr

21E. Delagnes Saclay Dec 3rd 2009.

ENC simul for SVT with AFTER-like FE

•Detector Parameters taken from “equivalent Noise Charge calculations for Barrel Modules of the SVT” (excepted Idet)

•Simulations on :

• 3 ranges + 3 ranges with 40pF added (to simulate a kapton cable):

•3 shaping times (50 ns,100ns, 200ns).

•2 bias currents for input transistor (5 &6mW/ch).

Page 22: CLAS12 Micromegas Tracker: FE electronics eric.delagnes@cea.fr

22E. Delagnes Saclay Dec 3rd 2009.

SVT ENC simulation: noise contributions, 5.5mW/ch/ tp=50ns

ENC is clearly dominated by serie noise => Improvementexpected for higher tp

SVT Note (tp=65ns) (reference)=>

FEMTC model(tp=50ns) =>

Page 23: CLAS12 Micromegas Tracker: FE electronics eric.delagnes@cea.fr

23E. Delagnes Saclay Dec 3rd 2009.

SVT ENC simulation: varying tp, IPOL

With tp>=100ns & Power=6.5mW => ENC< 2000 e- (S/N>11) for range 1&2 including 40pF kaptons cables :

We could imagine to move SVT electronics away…

Page 24: CLAS12 Micromegas Tracker: FE electronics eric.delagnes@cea.fr

24E. Delagnes Saclay Dec 3rd 2009.

Short term plans.

•No manpower in microelectronics for this project before March 2010.

•VFE part with 50ns shaping is currently designed for GET.

•Study the use of this chip with Silicon detectors.

•Definition of Digital/DAQ electronics and of integration => Irakli talk.

•Before summer 2010: Submission of a small size FE chip prototype :

–16 channels x 128 cells for lower prototype cost.

–Test during the fall.

•Check the possibility to use APV:

– “successful test” with new large Micromégas of COMPASS last summer , but detailed analysis of beam data are required to check the efficiency).