SmartClip™ SL3 and Clarity™ SL Self-Ligating Brackets
Archwire Sequence and Intervals -- .022 SlotRecommended by Anoop Sondhi, DDS, MS
![Page 2: Clarity™ SL and SmartClip™ SL3 Self-Ligating BracketsBeta III Titanium. 8-10 weeks: 16-30 weeks. Provide torque control, arch consolidation, use of inter-arch elastics.019 x .025](https://reader034.fdocuments.in/reader034/viewer/2022042105/5e83af199c1c8b343b66523b/html5/thumbnails/2.jpg)
2© 2010 3M. All Rights Reserved.
Archwire Sequence Tutorial On-Line
View an on-line tutorial on Archwire Sequencing by Dr. Anoop Sondhi and receive CE credit
Visit www.3MUnitekTraining.comClick on “CE Classes”Select “The SmartClip™ and Clarity™ SL Self-Ligating Treatment Systems: Recommended Archwire Sequences”
SmartClip™ SL3 and Clarity™ SL Self-Ligating Brackets
![Page 3: Clarity™ SL and SmartClip™ SL3 Self-Ligating BracketsBeta III Titanium. 8-10 weeks: 16-30 weeks. Provide torque control, arch consolidation, use of inter-arch elastics.019 x .025](https://reader034.fdocuments.in/reader034/viewer/2022042105/5e83af199c1c8b343b66523b/html5/thumbnails/3.jpg)
3© 2010 3M. All Rights Reserved.
Wire Sequence and Intervals
Archwire Appointment Interval Total Duration Function
.012 or .014 Nitinol Super-Elastic 8 weeks 8 weeks Preliminary alignment,
leveling and rotation
.014 or .016 Nitinol Classic Tandem 8 weeks 8 weeks Complete alignment,
leveling and rotation
.017 x .025 Beta III Titanium 8-10 weeks 16-30 weeks
Provide torque control, arch consolidation, use
of inter-arch elastics.019 x .025
Beta III Titanium or Stainless Steel
8-10 weeks 16-30 weeks
Retraction Arches 6-8 weeks 12-24 weeksSpace closure, retraction into
extraction sites
SmartClip™ SL3 and Clarity™ SL Self-Ligating Brackets
![Page 4: Clarity™ SL and SmartClip™ SL3 Self-Ligating BracketsBeta III Titanium. 8-10 weeks: 16-30 weeks. Provide torque control, arch consolidation, use of inter-arch elastics.019 x .025](https://reader034.fdocuments.in/reader034/viewer/2022042105/5e83af199c1c8b343b66523b/html5/thumbnails/4.jpg)
4© 2010 3M. All Rights Reserved.
.014 Nitinol SE
.016 Nitinol Classic
Tandem
.017 x .025 Beta III Titanium
Finishing Elastics
Archwire Sequence for Class I, Minor Crowding, Non Extraction
Mx./Md. .019 x .025 Beta III Titanium
SmartClip™ SL3 and Clarity™ SL Self-Ligating Brackets
![Page 5: Clarity™ SL and SmartClip™ SL3 Self-Ligating BracketsBeta III Titanium. 8-10 weeks: 16-30 weeks. Provide torque control, arch consolidation, use of inter-arch elastics.019 x .025](https://reader034.fdocuments.in/reader034/viewer/2022042105/5e83af199c1c8b343b66523b/html5/thumbnails/5.jpg)
5© 2010 3M. All Rights Reserved.
Archwire Sequence for Class I, Moderate Crowding, Non Extraction
Mx.
Md. .014 Nitinol SE
.016 Nitinol Classic
Tandem
.019 x .025 Beta III Titanium
.014 Nitinol SE and .016 Nitinol Classic Tandem
.019 x .025 Beta III Titanium
FinishingElastics
.012 Stainless Steel Sondhi Contact
Opening Archwire with Space
Opening Loop*
.014 Nitinol SE
*For details, please view the CE Class titled the “SmartClip™ and Clarity™ SL Self-Ligating Treatment Systems: Recommended Archwire Sequences” on 3MUnitekTraining.com.
.017 x .025 Beta III Titanium
.017 x .025 Beta III Titanium
SmartClip™ SL3 and Clarity™ SL Self-Ligating Brackets
![Page 6: Clarity™ SL and SmartClip™ SL3 Self-Ligating BracketsBeta III Titanium. 8-10 weeks: 16-30 weeks. Provide torque control, arch consolidation, use of inter-arch elastics.019 x .025](https://reader034.fdocuments.in/reader034/viewer/2022042105/5e83af199c1c8b343b66523b/html5/thumbnails/6.jpg)
6© 2010 3M. All Rights Reserved.
.014 Nitinol SE
.014 Nitinol SE
.016 Nitinol ClassicTandem
FinishingElastics
.017 x .025 Beta III Titanium
.019 x .025Beta III Titanium
or .021 x .025 Steel Hybrid
.019 x .025Beta III Titanium
or Steel with loop for Forsus™
Class II Corrector
Archwire Sequence for Class II, Non Extraction
Mx.
Md.
Forsus™ Class II
Corrector
SmartClip™ SL3 and Clarity™ SL Self-Ligating Brackets
![Page 7: Clarity™ SL and SmartClip™ SL3 Self-Ligating BracketsBeta III Titanium. 8-10 weeks: 16-30 weeks. Provide torque control, arch consolidation, use of inter-arch elastics.019 x .025](https://reader034.fdocuments.in/reader034/viewer/2022042105/5e83af199c1c8b343b66523b/html5/thumbnails/7.jpg)
7© 2010 3M. All Rights Reserved.
Archwire Sequence for Extraction Arch, Maximum Anchorage
.012 or .014 Nitinol SE
.016 NitinolClassic Tandem
.018 Stainless Steel with Nitinol
Retraction Springs
.019 x .025 Beta III Titanium Retraction Arch
.019X.025Beta III Titanium
FinishingElastics
SmartClip™ SL3 and Clarity™ SL Self-Ligating Brackets
![Page 8: Clarity™ SL and SmartClip™ SL3 Self-Ligating BracketsBeta III Titanium. 8-10 weeks: 16-30 weeks. Provide torque control, arch consolidation, use of inter-arch elastics.019 x .025](https://reader034.fdocuments.in/reader034/viewer/2022042105/5e83af199c1c8b343b66523b/html5/thumbnails/8.jpg)
8© 2010 3M. All Rights Reserved.
Archwire Sequence for Extraction Arch, Minimum Anchorage
.012 or .014 Nitinol SE
.016 NitinolClassicTandem
.019 x .025 Beta III Titanium or
.019 x .025 SteelRetraction Arch
.017 x .025Beta III Titanium
or .019 x .025 Steel Hybrid
.019 x .025Beta III Titanium
or .021 x .025 Hybrid Archwire
Elasticsif necessary