Clarification Contract Package JNNURM/AJM-PUSHK/WW/02 1 of 27 CLARIFICATIONS FOR AJMER- PUSHKAR STP Package No.- JNNURM/STP/Ajmer/WW/02 Name of Work- Design, Construction, Supply, Installation, Testing & Commissioning of Civil, Mechanical and Electrical works and Operation & Maintenance for 5 years of 13 MLD Sewage Treatment Plant at Anasagar Ajmer based on cyclic activated sludge Process/ SBR technology, and 1 no. Pumping Station at Ajmer & 1 no. Pumping Station at Pushkar and 3.50 MLD Sewage Treatment Plant (Anaerobic pond & Facultative pond) at Pushkar (under Turnkey basis) S. No. Reference Query Reply of UIT, Ajmer Queries/clarification raised by M/s Arvind Ltd, Ahmedabad 1 Vol.-I, section II, Page no.1 Cl. No. 4.3, Eligibility Criteria : Technical Experience We request you to consider the experience criteria including requirements specified under clause II (a) can be met by any of the JV member and not necessary by lead partner of JV. Bid conditions shall be adhered. 2 Vol.-I, section II, Page no.2 Cl. No. 4.3, Financial Criteria Average Annual turn over.net worth ,available working capital specified under this clause can be met by business of companies and not only construction. Bid conditions shall be adhered.

Transcript of CLARIFICATIONS FOR AJMER- PUSHKAR STP · CLARIFICATIONS FOR AJMER- PUSHKAR STP ... Treatment Plant...

Page 1: CLARIFICATIONS FOR AJMER- PUSHKAR STP · CLARIFICATIONS FOR AJMER- PUSHKAR STP ... Treatment Plant at Anasagar Ajmer based on cyclic activated sludge Process/ SBR technology, ...

Clarification Contract Package JNNURM/AJM-PUSHK/WW/02

1 of 27

CLARIFICATIONS FOR AJMER- PUSHKAR STP

Package No.- JNNURM/STP/Ajmer/WW/02

Name of Work- Design, Construction, Supply, Installation, Testing & Commissioning of Civil, Mechanical and Electrical works and Operation & Maintenance for 5 years of 13 MLD Sewage Treatment Plant at Anasagar Ajmer based on cyclic activated sludge Process/ SBR technology, and 1 no. Pumping Station at Ajmer & 1 no. Pumping Station at Pushkar and 3.50 MLD Sewage Treatment Plant (Anaerobic pond & Facultative pond) at Pushkar (under Turnkey basis)

S. No. Reference Query

Reply of UIT, Ajmer

Queries/clarification raised by M/s Arvind Ltd, Ahmedabad

1

Vol.-I, section II, Page no.1 Cl. No. 4.3,

Eligibility Criteria : Technical Experience

We request you to consider the experience criteria including requirements specified under clause II (a) can be met by any of the JV member and not necessary by lead partner of JV.

Bid conditions shall be adhered.

2 Vol.-I, section II, Page no.2 Cl. No. 4.3,

Financial Criteria

Average Annual turn over.net worth ,available working

capital specified under this clause can be met by

business of companies and not only construction.

Bid conditions shall be adhered.

Page 2: CLARIFICATIONS FOR AJMER- PUSHKAR STP · CLARIFICATIONS FOR AJMER- PUSHKAR STP ... Treatment Plant at Anasagar Ajmer based on cyclic activated sludge Process/ SBR technology, ...

Clarification Contract Package JNNURM/AJM-PUSHK/WW/02

2 of 27

S. No. Reference Query

Reply of UIT, Ajmer

3 Vol.-I, section II, Page no.2 Cl. No. 18.1,

Kindly clarify the Bid validity period. As in CI-17, 1 it is

mentioned that validity will be 180+30 days, Whereas in

B.G. format it is given 120 days.

The bid validity shall be 180 days as per clause 17.1 of section II. As per clause 18.1 of section II the bid security shall be valid for 180+30 days, The form of BG is a sample format only. The time shall be as per above clause.

4 Vol.-I, section V, sub-section II, Page no.2 Cl. No. 18.1,

Raw Sewerage Pump :

As per tender design Avg. flow is 17.7 MLD where as Pump

capacity has been considered as 13.0 MLD Avg. flow .please

clarify the same.

Refer addendum no-1; Sr. no.1

5 Vol.-I,

section V,

sub-section

II, Page no.6

Cl. No. 2.4.

As mentioned in CI-2.4 that the primary units (i.e. screen &

greet chamber are to be considered to meet the

requirement of 17.7 MLD flow. please confirm whether

Mechanical structure of primary unit to be also designed

and considered as per 17.7 MLD flow.

Bid conditions shall be adhered.

6 General For bypass channel for 13 MLD STP, can we provide RCC

pipe instead of channel? PI. advise.

RCC NP-4 pipe can also be considered in place of RCC channel.

7 Vol.-I,

section V,

sub-section

II, Page

no.10,11,12

.

Qty of sludge transfer pumps: In technical specification

given in Vol. I -Sec V. sub section-II, CI-9.2 pg-10 ,pump

capacity is mentioned @ 25m3/hr while in page 10,11 of

vol-I, Sec V, subsection-IV, CI 9.0 specifies 15 m3/hr

capacity .please clarify the same.

Refer Addendum- I; Sr. no.2

Page 3: CLARIFICATIONS FOR AJMER- PUSHKAR STP · CLARIFICATIONS FOR AJMER- PUSHKAR STP ... Treatment Plant at Anasagar Ajmer based on cyclic activated sludge Process/ SBR technology, ...

Clarification Contract Package JNNURM/AJM-PUSHK/WW/02

3 of 27

S. No. Reference Query

Reply of UIT, Ajmer

8 Vol.-I, section

V, sub-

section II,

Page no.10.

Blower Capacity : : in technical specification given in

Vol-I, Sec V, .sub-section-II, CI-9.2 Pg-10 capacity is

mentioned @ 350m3/hr while in page,11 of vol I,Sec.- V,

subsection-IV, CI 9.0 specifies 150 m3/hr capacity .please

clarify the same.

Refer Addendum- I; Sr. no.3

9 Vol.-I, section V, sub-section II, Page no.11.

Centrifuge :- : In technical specification given on page-11 Vol-Sec V.sub section-II, CI-9.3 no. of SBC is 3 (2w+1s) & capacity of SBC is mentioned 25m3/hr while in page 12 of vol-Sec V, subsection-IV, CI 9.0 indicates 15 m3/hr capacity .of SBC & on page- 31.CI-13 no of centrifuge mentioned is 1+1 and capacity is suit 50% requirement. Please clarify the same.

Refer Addendum- I; Sr. no.4

10 General Please provide flow diagram & HFD for 3.5 MLD STP. Refer Addendum- I; Sr. no.5

11 Vol.-I, section

V, sub-

section, Page

no13 Cl. No.

3.4.

Please provide value of COD in raw sewage for 3.5 MLD

plant

Refer Addendum –I; Sr. no.6

12 Vol.-I,

section V,

sub-section,

Page no13

Cl. No. 3.3

Kindly confirm the peak flow for 3.5 MLD STP. As in CI-

3.3 & 3.5 peak flow is given 10.08 MLD while in Vol-1

sect-5 CI-1 pg-21 mentions peak flow of 9.26 MLD.

Refer Addendum –I; Sr. no.7

Page 4: CLARIFICATIONS FOR AJMER- PUSHKAR STP · CLARIFICATIONS FOR AJMER- PUSHKAR STP ... Treatment Plant at Anasagar Ajmer based on cyclic activated sludge Process/ SBR technology, ...

Clarification Contract Package JNNURM/AJM-PUSHK/WW/02

4 of 27

S. No. Reference Query

Reply of UIT, Ajmer

13 General PI. specify distance of disposal site for disposal of any

excess excavated earth to be disposed off from site.

At 13MLD STP, Anasagar site filling is required and as such no disposal of excess excavated earth material outside plant area will be required. At 3.5 MLD STP surplus earth may be disposed off up to 500m outside STP boundary or as per direction of Engineer In charge.

14 General We request you to provide 10% advance under payment

terms. This can be recovered by education from RA.

Bills.

Bid conditions shall be adhered.

15

General We request you to give Bid submission extension date for

at least 30 days from date of providing pre bid replies.

Refer Addendum –I; Sr. no.9

16 Vol. II,

Item H,

Pg. 9

Civil work: As per tender specification of Retaining

wall/ compound wall for 13 MLD STP. We have

considered Rubble Masonry of the length of 1000 Mtr.

please confirm the same.

Bid conditions shall be adhered. Also, refer drawing (topography survey of land at Anasagar STP site).

17 General Please provide length of approach road and no. of Nallah

crossing for 13 & 3.5 MLD STP.

Refer Addendum I; Sr.no.11

It is responsibility of bidder to assess such work at his

own. The approach up to STPs shall be ascertained by

the bidder considering monsoon season

18 General Please specify the grade of concrete for building work

required for STP. Refer Addendum -1; Sr.no.14

19 General Please provide 80% secured advance for purchase of

steel & cement at site.

Bid conditions shall be adhered.

Page 5: CLARIFICATIONS FOR AJMER- PUSHKAR STP · CLARIFICATIONS FOR AJMER- PUSHKAR STP ... Treatment Plant at Anasagar Ajmer based on cyclic activated sludge Process/ SBR technology, ...

Clarification Contract Package JNNURM/AJM-PUSHK/WW/02

5 of 27

S. No. Reference Query

Reply of UIT, Ajmer

20 Vol.-I, section

V, sub-

section II,

Page no.30

Length of compound wall : please specify individual length

of compound wall SPS at Ajmer & Pushkar.

Refer Addendum I; Sr.no.15

Queries/clarification raised by SMS Paryavaran Limited, New Delhi.

1 Vol.I/ section

I

The Power rate for the evolution as mentioned in clause

37.6 on page 21 of 25 section volume 1 is

Rs. 4.89/kw.

This rate mentioned in clause is for evaluating

capitalized cost for differential power loading only. For

capitalized cost refer Annexure II of addendum no.1

2 Vol.II/

Page 20

Item no. 4

Refer envelop B volume 2 page 20 of 23 item No.4 kindly

confirm the diameter of the DI pipe which is written as

2500 mm. We feel it may be 250 mm Please confirm.

Similarly confirm if the DI specials to be including in the

cost of the pumping main.

Refer Addendum I; Sr. no.16 DI specials are to be included in the cost of the pumping main.

Page 6: CLARIFICATIONS FOR AJMER- PUSHKAR STP · CLARIFICATIONS FOR AJMER- PUSHKAR STP ... Treatment Plant at Anasagar Ajmer based on cyclic activated sludge Process/ SBR technology, ...

Clarification Contract Package JNNURM/AJM-PUSHK/WW/02

6 of 27

S. No. Reference Query

Reply of UIT, Ajmer

3

Vol.I

section I

Differential Power Loading: You have indicated a

discounting factor will be considered @ 10% P.A. for 10

years kindly quantify the discounting factor and differential

power loading considering the lowest power consumption

as zero will be done on the other bidders. We request

following confirmation:

Kindly confirm that the guaranteed power

consumption for loading process should include the STP

and pumping station. The power consumption for yard

lighting building electrification should not be considered by

you for power loading.

Refer clause 37.6 section I page 21 of 25 and also refer Addendum-I, Sr. 30.

4

Vol.I

section I,

page 22

Refer note 2 on page 22 of 25 sections 1 volume 1.

Kindly confirm the period till which the cost of power in

excess of the guaranteed power is to be paid by the

contractor.

Refer Addendum-I; Sr. no.31

5

Vol.I

section II,

page1 ,

clause 4.3

Refer bidding data clause 4.3 page 1 of 3 section 2

volume kindly confirm that experience on moving bed

bio-reactor. Which is the part of activated slugged

process will be also be considered all other conditions

regarding MOU with technological provider remaining

unchanged.

Bid conditions shall be adhered.

Page 7: CLARIFICATIONS FOR AJMER- PUSHKAR STP · CLARIFICATIONS FOR AJMER- PUSHKAR STP ... Treatment Plant at Anasagar Ajmer based on cyclic activated sludge Process/ SBR technology, ...

Clarification Contract Package JNNURM/AJM-PUSHK/WW/02

7 of 27

S. No. Reference Query

Reply of UIT, Ajmer

6 General Security/performance Guarantee: We understand that

total 10% security/ performance guarantee is required

on this contract and on submission of the same there

would not be any deduction on this account from the RA

bill.

Bid conditions shall be adhered.

7 General Mobilization advance: We request a mobilization advance

of 15% to be paid interest free against the Bank

Guarantee .This advance may be adjusted from the RA

bill.

Bid conditions shall be adhered.

8 General We request you to kindly accept the composite bank

guarantee to cover security cum advance the funding of

this bank guarantee is that it always remains in force for

the full value and the quantum of advance deducted gets

automatically converted into performance cum security

portion. This is accepted practice in organization such as

GAIL, ONGO, IOCL and other prestigious public

undertakings. WE request you to consider this practice as

applicable in this contract.

Bid conditions shall be adhered.

9 Vol. I ,

Section IV,

Page 49,

Clause 92

Refer clause 92 on page 49 section 4 volume 1. You

have asked for 500 sqft office space with furniture at Ana

sager and then stated that site office at Pushkar should

have 50% of the sitting arrangements. Kindly confirm

that 50% for which provisions mentioned be given at Ana

sager and 50% at Pushkar or you required the provisions

as mentioned at Ana Sagar alone and additional 50% at

Pushkar.

. The 50% of the space & furniture etc to be provided at Anasagar site shall be provided at Pushkar.

Page 8: CLARIFICATIONS FOR AJMER- PUSHKAR STP · CLARIFICATIONS FOR AJMER- PUSHKAR STP ... Treatment Plant at Anasagar Ajmer based on cyclic activated sludge Process/ SBR technology, ...

Clarification Contract Package JNNURM/AJM-PUSHK/WW/02

8 of 27

S. No. Reference Query

Reply of UIT, Ajmer

10 Vol. I ,

Section III,

Page 8,

Clause 8b

Refer clause 8 b on page 8 of 28 sections 3. You have

mentioned for preparation of the RA bill by the

engineering in charge would lead to 0.5% deducted of

such bill. We request you to delete this clause as the RA

bill if not by the contractor in a particular month cannot be

forced upon by him that too by reduced value.

Bid conditions shall be adhered.

11 General Kindly confirm that the contract of these 2 STP one at Ana

Sagar and another at Pushkar is not a divisible contract

and the same will be evaluated as one contract and

awarded accordingly.

Confirm

12 General In technical specifications sub-section II deals in

specifications and IV for mechanical works for same item

specification in some of the cases vary, Please confirm

which has to be followed in case of contradictions.

Refer clause 10.2 of section I page no.7. In the event of any discrepancy or conflicts within the bidding document the priority given in above clause shall be applicable. Scope of work shall prevail over technical specification.

13 Vol. I ,

Section V,

Page 5,

Clause 5&6

Requirement of two mechanical fine screens and 2 grit

removing units (page 5 section V clause 5 &6) appears to

be quite high for such capacities of the plants. We feel

one working and one standby will meet the purpose.

Bid conditions shall be adhered.

Page 9: CLARIFICATIONS FOR AJMER- PUSHKAR STP · CLARIFICATIONS FOR AJMER- PUSHKAR STP ... Treatment Plant at Anasagar Ajmer based on cyclic activated sludge Process/ SBR technology, ...

Clarification Contract Package JNNURM/AJM-PUSHK/WW/02

9 of 27

S. No. Reference Query

Reply of UIT, Ajmer

14 Vol. I ,

Section V,

Page 11

Dewatering requirement required in page 11 section 5

sub-section II appears to be quite high such as 3 nos

centrifuges (one working and one stand by), accordingly 3

feed pumps etc. We feel one working and one stand by

are good enough. Capacities should be left to design

requirement. limiting one working and one standby.

Bid conditions shall be adhered.

15 General The NGL is about 1.2 meter below FSL of lake as per

DNIT therefore the SBR area has to be filled & compacted

to stand the Structure thrust & load. Please confirm.

Confirm

16 Vol. I,

Section VI

In DNIT the contour is provided with out specifying the

plotted area as proposed.

Refer other drawings enclosed with bid document.

17 General The quality or treated effluent as asked for in DNIT is just

impossible to achieve after SBR without tertiary treatment.

Please confirm

Bid conditions shall be adhered. Bidder can add any other unit or equipment to fulfill bid condition.

18 Vol.I section

V,

page 8,

Cl. No.

2.5.2

Treated water quality BOD<5ppm,TSS<10, TSS from

Biological rector will contribute for BOD at present case

TSS level BOD <5ppm is not achievable ,We suggest to

take the TSS<5ppm. We also suggest to confirm the

Treatment in the amendment for achieving BOD ppm <5

& TSS < 5 ppm.

Bid conditions shall be adhered.

Page 10: CLARIFICATIONS FOR AJMER- PUSHKAR STP · CLARIFICATIONS FOR AJMER- PUSHKAR STP ... Treatment Plant at Anasagar Ajmer based on cyclic activated sludge Process/ SBR technology, ...

Clarification Contract Package JNNURM/AJM-PUSHK/WW/02

10 of 27

S. No. Reference Query

Reply of UIT, Ajmer

19 Vol.I section

V,

Sub section

II, page 7 Cl.

No. 8

Volume-1 section 5 Cl. No. 8.1, NO settling during fill and

decant is acceptable, Our associates Technology provider

-ITT advance SBR technology with more than 1000

installations are working on the same principal

(Continuous fill and discharge). We request you to

consider the same.

Bid condition shall be adhered, However bidder may provide suitable system subject to guaranteed treated effluent parameter.

Queries/clarification raised by Hindustan Dorr Oliver Ltd., Mumbai.

1 General Subject Soft Copy of Tender :-

We request you to kindly provide the tender in soft copy to

enable us to take the quotation from our vendors at the

earliest.

Soft copy may be down loaded from UIT, Ajmer website.

2 Vol.I section

V,

Sub section

II, page 29

Raw Water Sewage Transfer Pumps :-

Please confirm the no. of raw sewage pumps with flow

rates and required no. of standby for both Ajmer &

Pushkar Pumping station.

Refer Addendum-I; Sr. No. 18

3 General DG Set:-

We request you to kindly let us know the number of hours

the DG set would work per day.

DG set would run in case of emergency during power failure.

4 General Nallah at Boundry Wall :-

At site there is a nallah flowing in to the site area. please

clarify whether the realignment of this nallah is our scope

and up to where it has to be routed and type of routing.

Refer Addendum I; Sr. no.11

Page 11: CLARIFICATIONS FOR AJMER- PUSHKAR STP · CLARIFICATIONS FOR AJMER- PUSHKAR STP ... Treatment Plant at Anasagar Ajmer based on cyclic activated sludge Process/ SBR technology, ...

Clarification Contract Package JNNURM/AJM-PUSHK/WW/02

11 of 27

S. No. Reference Query

Reply of UIT, Ajmer

5 Vol.I section

V,

Sub section

II, page

Invert Level of Discharge of treated sewage from

anaerobic pond :-

Kindly provide us the high flood level at STP site outfall

sewer diameter, invert level, FSL of the nallah for

disposal.

Effluent will flow in open land area no such nalah is there however it shall be confirmed by the bidder at site. Out fall sewer Dia- 500 mm RCC Invert level 470.90 M

6 General Please inform the cost of water for testing of structure will

be supplied by whom?

Cost of water for testing of structure shall be borne by the bidder.

7 General Instrument & control :-

We requested you to kindly confirm the type of

automation requirement for the PLC and control room. We

also request you to kindly forward us the system

architecture drawing for the same.

The type of automation requirement for PLC & control room shall meet the requirement to operate STP smoothly. Contractor has to submit the design and drawing for approval. For approval procedure please refer clause no.5 & 6 of section V, sub section –I page no.12&13 of bid document.

8 General Design Basis :-

As per tender specification one source of 11 kv 50c/s

electrical power is been provided at a single point we

request you to kindly forward us the location of incoming

cable substation for both Ajmer & Pushkar STP plant.

At Anasagar site, AVVNL Grid substation is located at opposite side of the road. However bidders are advised to assess the site situation of their own.

9 General We request you to kindly provide us the standard drawing

of pumping stations at Ana sagar & Pushkar for our

reference.

Pumping stations shall meet the all necessary requirements as per standards. Regarding Drawings & Design please refer clause no.5 & 6 of sub section –I, section V page no.12&13.

10 General We request you to kindly forward us the process &

instrumentation diagram & hydraulic flow diagram for

Pushkar sewage treatment plant.

Refer Addendum I; Sr. no.5

Page 12: CLARIFICATIONS FOR AJMER- PUSHKAR STP · CLARIFICATIONS FOR AJMER- PUSHKAR STP ... Treatment Plant at Anasagar Ajmer based on cyclic activated sludge Process/ SBR technology, ...

Clarification Contract Package JNNURM/AJM-PUSHK/WW/02

12 of 27

S. No. Reference Query

Reply of UIT, Ajmer

11 Pumping station at Ajmer & Pushkar :-

As per tender specification O&M for pipeline from

Panchsheel pumping station to STP is in Contractors

scope we request you to kindly forward us the details of

instruments, rout ling of pipeline controlling devices on

discharge of sewage pumping station

Design & drawings of SPSs & rising main is in the scope of contractor including all necessary requirements to run the system smoothly.

12 Vol.I ,

section V,

Sub section

VI

In clause no 8.4 pg 8.vol/1 section V employer’s

requirement sub section VI of tender point no 3 Motors

above 5 KW & up to 30KW shall have star delta starter

,but as per clause no 6 point C-3 star delta starter is to be

considered for motors from 10 KW & up to 45 KW please

clarify .

Bid conditions shall be adhered. There is no such discrepancy.

Queries/clarification raised by Doshion Veolia Water Solution pvt. Ltd., Ahemdabad

1 General Kindly extend the bid submission date at least after 40

days from the issuing of pre bid answers.

Refer addendum I; Sr. No.9

2 Vol.I ,

section II

Kindly allow worldwide experience.

Kindly allow ETP (6.5 MLD capacity) experience as

eligibility criteria .

Bid conditions shall be adhered.

3 Vol.I ,

section III

Cl. 38

Bidder will pay sales tax and other taxes. We understand

that UIT will pay service tax to the contractor as extra .Pls

confirm.

Bidder has to bear all the tax liabilities as per bid conditions.

4 General We understand that excise duty and custom duty

exemption certificate will be issued. Kindly confirm.

Bid conditions shall be adhered.

Page 13: CLARIFICATIONS FOR AJMER- PUSHKAR STP · CLARIFICATIONS FOR AJMER- PUSHKAR STP ... Treatment Plant at Anasagar Ajmer based on cyclic activated sludge Process/ SBR technology, ...

Clarification Contract Package JNNURM/AJM-PUSHK/WW/02

13 of 27

S. No. Reference Query

Reply of UIT, Ajmer

5 General Being this prestigious project, it will be better to select only

financially sound companies in order to smooth and timely

completion of the project, Therefore we request to review

financial criteria like value of single work average annual

turnover and net worth etc. We request you kindly revise

average turnover should be equivalent to project cost and

net worth should be Rs 5 crore and working capital should

be 10 cr.

Bid conditions shall be adhered.

6 General It is mentioned in Metcalf & Eddy that Return Activated

sludge system is not required in SBR Process. Please

provide clarification,

Bid conditions shall be adhered.

7 Vol. I,

section I, Cl.

37.6, page

22, Sr. no. C

It is mentioned that minimum power consumption given by

any bidder shall be considered as Zero power loading

here in the interest of client/project we request you to

specify minimum power consumption value for both STP

& pumping stations since its our consumption values

(which are not authentic ones.) Just to win the project in

terms of price after award of job, it creates lots of issues to

client too.

Bid conditions shall be adhered.

8 Vol. I,

section IV,

Cl. 5A2,

page 4

It states any extra work required during execution to

comply with amended guidelines of JNNURM---UIT shall

not be paid extra We hereby request you to pay extra if

any amendment is given under project time schedule & it

leads to any sort of cost increase.

Bid conditions shall be adhered.

Page 14: CLARIFICATIONS FOR AJMER- PUSHKAR STP · CLARIFICATIONS FOR AJMER- PUSHKAR STP ... Treatment Plant at Anasagar Ajmer based on cyclic activated sludge Process/ SBR technology, ...

Clarification Contract Package JNNURM/AJM-PUSHK/WW/02

14 of 27

S. No. Reference Query

Reply of UIT, Ajmer

9 Vol. I,

section IV,

Cl. 43.3,

page 20

Pl. specify area to be provided for field laboratory.. To suite the testing facility requirement.

10 Vol. I,

section V,

Cl. 3.3, page

12

It is mentioned that inlet chamber to be designed for 10.08

MLD flow However clause 3.2.1 state Avg. flow as 3.5

MLD & peak factor as 2.5 which corresponds to peak flow

of 8.7 5 MLD Pl. advice.

Refer addendum I; Sr. no.8

11 Vol. I,

section V,

Cl. 4.1, page

15

At Ajmer Qavg is mentioned as 25.35 LPS which is equal

to 2.19 MLD only & its not matching with 13 MLD similarly

at pushkar Q avg is specified as 7.75 LPS which is equal

to 0.67 MLD only & it's not matching with 3.5 MLD also on

page 28 vol 1 section V subsection IT, it says peak factor

as 3 PI check & advice .

Capacities of intermediate pumping stations at Ajmer and Pushkar are different from the respective capacities of STPs.

12 Vol. I,

section V,

Cl. 4.1, page

15

At Ajmer pumping main is 350 mm DI K9-2400 m & at

pushkar 250 mm DI K9 -1700 m whereas Pg 28 specifies

at Ajmer-Pumping main is 300 mm DI K7-2400 m & at

Pushkar -200 mm DI K7-1555 m. further at Pushkar its

mentioned pipe from old pumping station to STP.PI.

advised on old pumping station clause too.

Refer Addendum I; Sr.no.16

13 Vol. I,

section V,

sub section I

, page 3

Under details of operations & maintenance scope of work

its mentioned that fuel (Diesel) is in contractors scope of

supply We believe it will be reimbursed on actual as we

are not aware about hours of power failure/day,

Refer Addendum I; Sr.no.32

Page 15: CLARIFICATIONS FOR AJMER- PUSHKAR STP · CLARIFICATIONS FOR AJMER- PUSHKAR STP ... Treatment Plant at Anasagar Ajmer based on cyclic activated sludge Process/ SBR technology, ...

Clarification Contract Package JNNURM/AJM-PUSHK/WW/02

15 of 27

S. No. Reference Query

Reply of UIT, Ajmer

14 Vol. I,

section V,

sub section

II , page 3

For raw sewage pumps design flow is specified as 17.7

MLD & corresponding peak flow is 40 MLD However

pump capacitates mentioned are note matching ,PI check

& confirm.

Refer Addendum I; Sr.no.1

15 Vol. I,

section V,

sub section

II , page 4

Under clause 3.2 it is mentioned as rising main MOC as

CI class B pipeline whereas at other places as mentions

in query it is specified as DI PI advice,

Bid conditions shall be adhered. The rising mains are to be provided of DI and installations inside pumping stations would be of CI Class LA.

16 Vol. I,

section V,

sub section

II , page 4

Clause 4 describes about collecting channels PI explains

the requirement/services of the channel process as we

have not understood the same.

Collecting channel will receive Raw sewage after pumping from Raw sewage sump and will lead to fine screen chamber through gravity.

17 Vol. I,

section V,

sub section

II , page 5

Under clause 5 it is mentioned 2 Mechanical working fine

screens to be provide whereas further description says I

mechanical working & I mechanical standby each for peak

flow PI. advice.

Bid conditions shall be adhered.

18 Vol. I,

section V,

sub section

II , page 5

Under clause 5 it is mentioned to provide SS Chute for

screenings disposal whereas at other place it is MSEP.PI.

advice.

Bid conditions shall be adhered.

19 Vol. I,

section V,

sub section

II , page 5

Under clause 6 it is asked to provide ultrasonic flow

transmitter on common header of raw sewage pumps

discharge Can we provide electromagnetic in place of

ultrasonic? PI advice.

Refer Addendum I; Sr. no.33

Page 16: CLARIFICATIONS FOR AJMER- PUSHKAR STP · CLARIFICATIONS FOR AJMER- PUSHKAR STP ... Treatment Plant at Anasagar Ajmer based on cyclic activated sludge Process/ SBR technology, ...

Clarification Contract Package JNNURM/AJM-PUSHK/WW/02

16 of 27

S. No. Reference Query

Reply of UIT, Ajmer

20 Vol. I,

section V,

sub section

II , page

10,11

Capacities specified for sludge transfer plumps sludge

sump mixing air blower & centrifuge is different on

specified page nos. PI check & advice.

Refer Addendum I; Sr. no.2,3 &4

21 Vol. I,

section V,

sub section

II , page 16

At Ajmer It is specified to provide compound wall whereas

at pushker it is specified to provide barbed wire fencing

along STP boundary wall .PI advice on page 16

compound wall length is mentioned as 1000 m whereas

on page 30 its mentioned as 600 m PI check & advise on

compound wall length required for both STP: s & pumping

stations separately .

Refer Addendum I; Sr. no.15

22 Vol. I,

section V,

sub section

II , page 20

cl.no.8

It is specified sludge disposal distance to be considered

as 10 km where under subsection X pg. 15. clause 8, It is

mentioned as 20 km pl. advise.

Refer addendum I; Sr. no.37

23 Vol. I,

section V,

sub section

II , page 20

cl.no.9

PI. specifies distance to be considered for excess

excavated earth disposal ,

At 13MLD STP, Anasagar site filling is required and as such, no disposal of excess excavated earth material outside plant area will be required. At 3.5 MLD STP surplus earth material may be disposed off up to 500m outside STP boundary or as per direction of Engineer In charge.

24 Vol. I,

section V,

sub section

II , page 23

cl.no.5.2

PI specify sludge drying pond dimensions /Volume to be

constructed.

To suite the requirement as per standards.

Page 17: CLARIFICATIONS FOR AJMER- PUSHKAR STP · CLARIFICATIONS FOR AJMER- PUSHKAR STP ... Treatment Plant at Anasagar Ajmer based on cyclic activated sludge Process/ SBR technology, ...

Clarification Contract Package JNNURM/AJM-PUSHK/WW/02

17 of 27

S. No. Reference Query

Reply of UIT, Ajmer

25 Vol. I,

section V,

sub section

II , page 21

& 24

On page 21 it is mentioned that specification given for

equipments like screen. grit etc. shall remain same for

both 13 STP & 3.5 MLD STP whereas under design

requirements , for mechanical cleaned coarse screens no

is specified as 2 for pushkar STP Pg 21 for Ajmer STP

coarse screen is 1 no. mechanical & 1 no. manual PG 2

Pl advise.

Refer Addendum I; Sr. No.19

Vol. I,

section V,

sub section

II , page 25

Similarly SOR for grit chamber is specified as different for

3.5 MLD STP pg 25 & 13 MLD STP pg 6 pl check &

advise.

Refer Addendum I; Sr. No.36

26 Vol. I,

section V,

sub section

II , page 28

Under coarse screen chamber para it is mentioned as 2

coarse screen chamber at pumping station whereas

design data mentions 2 mechanical screen & manual

screen PI advice similarly it is mentioned manual screen

shall be ahead in the flow direction pI explain on this .

Refer Addendum I; Sr. No.20

27 Vol. I,

section V,

sub section

II , page 11

and sub

section IV,

page 30

Centrifuge waited part MOC is specified as SS 304

whereas subsection IV pg 30 specifies as SS316 L.PI

advice.

Refer Addendum I; Sr. No.35

28 General PI provides site/plot plan with dimensions & Contour plan

for both Ajmer & Pushkar pumping station & STP site if

possible in soft copy along with printouts.

Refer attached drawings and also enclosed with addendum

Page 18: CLARIFICATIONS FOR AJMER- PUSHKAR STP · CLARIFICATIONS FOR AJMER- PUSHKAR STP ... Treatment Plant at Anasagar Ajmer based on cyclic activated sludge Process/ SBR technology, ...

Clarification Contract Package JNNURM/AJM-PUSHK/WW/02

18 of 27

S. No. Reference Query

Reply of UIT, Ajmer

29 General We assume pumping station & STP will be coming on

same project site for Ajmer similar is the understanding for

Pushkar pumping station & STP PI advice.

Pumping station & STP site in both Ajmer and Pushkar are different.

30 General PI provides us soft copy of schedule X equipment

specifications .

Can be downloaded from UIT Ajmer web site

31 General We could not locate any drawing under schedule XI Pl

provides the same.

Drawings under schedule XI are to be provided by the bidders along with their bids.

32 Vol.I /

section V,

sub section

II, cl. 11

page 12

PI advice on treated water disposal pipe MOC .length size

for Amer & Pushkar STP & battery limits for treated water

pipe for both plants,

Refer Addendum I, Sr. no.22 for Ajmer STP. Refer Clause 5.2, page 23 para 3 for Pushkar STP.

33 General We requested you to give interest free mobilization

advance of 10%

Bid conditions shall be adhered.

34 General We also request you to extend tender submission date by

at least 25 days.

Refer addendum I; Sr. no.9

Queries/clarification raised by Shriram EPC Ltd., New Delhi.

1 Vol.-I, section II, Page no.2 Cl. No. 18.1,

The bid validity mentioned in the tender document is 180 days but in the format of bank guarantee the validity of BG is mentioned as 120 days please clarify the same.

The bid validity shall be 180 days as per clause 17.1 of section II. As per clause 18.1 of section II the bid security shall be valid for 180+30 days, The form of BG is a sample format only. The time shall be as per above clause.

Page 19: CLARIFICATIONS FOR AJMER- PUSHKAR STP · CLARIFICATIONS FOR AJMER- PUSHKAR STP ... Treatment Plant at Anasagar Ajmer based on cyclic activated sludge Process/ SBR technology, ...

Clarification Contract Package JNNURM/AJM-PUSHK/WW/02

19 of 27

S. No. Reference Query

Reply of UIT, Ajmer

2 General Clarify whether the interest free mobilization advance against bank guarantee will be paid to contractor or not.

Bid conditions shall be adhered.

3 Vol.I / section V, sub section II, cl. 11 page 12

Disposal channels length of treated sewage is not mentioned in the tender documents. please provide the same,

Refer Addendum I, Sr. no.22 for Ajmer STP. Refer Clause 5.2 , page 23 para 3 for Pushkar STP.

4 General Cost of third party inspection shall be borne by the employer

Fees for Third party inspection shall be deposited by bidder to the designated TPI agency of UIT,Ajmer. Same will be reimbursed from provisional sum by UIT after successful inspection.

5 General All the statutory permission required for the work execution shall be in the scope of owner.

All the statutory permission required for the work execution shall be in the scope of bidder. However department will help to the contractor for getting such permissions if any.

6 Vol.I / section V, sub section II,

Retaining wall to be constructed to protect from flooding as such length and height of retaining wall shall be provide to the contractor.

Refer addendum I;Sr. no.12

7 General A controlled blasting shall be allowed for hard rock excavation.

No blasting shall be permitted.

8 General Whether the supply and installation of required capacity of DG sets for running of pumping stations as well as STP are in the scope of bidder or in the scope of owner kindly clarify the same.

The supply and installation of required capacity of DG sets for running of pumping stations as well as STP are in the scope of bidder

Page 20: CLARIFICATIONS FOR AJMER- PUSHKAR STP · CLARIFICATIONS FOR AJMER- PUSHKAR STP ... Treatment Plant at Anasagar Ajmer based on cyclic activated sludge Process/ SBR technology, ...

Clarification Contract Package JNNURM/AJM-PUSHK/WW/02

20 of 27

S. No. Reference Query

Reply of UIT, Ajmer

9 Vol.I / section V, sub section VI,

Kindly clarify the mode of payment for diesel electricity consumable chemicals for running of STP and pumping station.

For mode of payment of diesel to run DG set please refer addendum no.1, Sr.no.32 & all other consumables & chemicals for running of STP & SPSs is in the scope of bidder/ contractor.

10 General Total electricity requirement for running of STP plant and pumping station are not clearly mentioned in the tender documents as such kindly clarify if it is in the scope of bidder.

Power consumption requirement of STP & SPS is in the scope of bidder. Bidder has to give guaranteed power consumption in the prescribed format.

11 General Kindly clarify whether electricity connection is available at different locations of STP and pumping station.

Refer clause 80 of section IV, Vol.I, Page no. 46. Contractor shall apply for permanent power connection of STP and SPS. During construction contractor shall be solely responsible for power connection.

12 General Disposal area for sludge shall be in the scope of employer. if required .

Bid conditions shall be adhered.

13 General Environmental clearance shall be in the scope of employer.

Consent to establish & consent to operate the STPs shall be applied by the contractor. The requisite fee shall be reimbursed to the contractor from provisional sum.

Queries/clarification raised by M.S. Khurana Engineering Limited, Ahemdabad 1 General Commercial:-

10 % interest free mobilization advance may be given at the start of the work against Bank guarantee.

Bid conditions shall be adhered.

Page 21: CLARIFICATIONS FOR AJMER- PUSHKAR STP · CLARIFICATIONS FOR AJMER- PUSHKAR STP ... Treatment Plant at Anasagar Ajmer based on cyclic activated sludge Process/ SBR technology, ...

Clarification Contract Package JNNURM/AJM-PUSHK/WW/02

21 of 27

S. No. Reference Query

Reply of UIT, Ajmer

2 General We request you to kindly sanction 90 % secured advance for the material procured & stacked at site.

Bid conditions shall be adhered.

3 General Space for office stores steel yard machinery yard and labor hutments etc may please be provided to us near the worksite free of cost.

Bidder has to make all the arrangement of his own, however STP site may be used during construction for these purpose.

4 General We may be permitted to submit the bank guarantee of IDBI bank for bid security the name of united western bank is given in indicative list of banks vide page 20 of section I of vol.1. Kindly note that united western bank is merged with IDBI bank since last three years.

The enclosed list with the bid document is indicative only and bidder can submit BG of any Nationalised or Scheduled bank of RBI.

5 General Kindly clarify whether service tax is applicable or not, if service tax is applicable for this project then the amount paid should be reimbursed to us on actual.

Bidder has to bear all the tax liabilities as per bid conditions.

6 General Increase in the existing taxes levies & duties after the date of submission of tender should be reimbursed to us.

Bidder has to bear all the tax liabilities as per bid conditions.

7 General New taxes duties & levies etc implemented by the government into force after the date of submission of the tender should be reimbursed to us since it is not possible for us to foresee such taxes & duties.

Bidder has to bear all the tax liabilities as per bid conditions.

8 General We request you kindly extend the date of submission from 17.6.10 to 1.7.10

Refer addendum I; Sr. no.9

Page 22: CLARIFICATIONS FOR AJMER- PUSHKAR STP · CLARIFICATIONS FOR AJMER- PUSHKAR STP ... Treatment Plant at Anasagar Ajmer based on cyclic activated sludge Process/ SBR technology, ...

Clarification Contract Package JNNURM/AJM-PUSHK/WW/02

22 of 27

S. No. Reference Query

Reply of UIT, Ajmer

9 Vol.I / section V, cl. 4.1, page 15

Technical - In volume 1 section V. page no15 cl. 4.1: DI k-7 pipe for rising main for Ajmer 300 mm dia-2400 Rmt, & 200 mm dia -1555 Rmt for Puskhar and where as on page no 28 of section 5 sub section II: DI K-9 pipe for rising main for Ajmer 350 mm dia -2400 Rmt & 250 mm dia -1700 Rmt for puskhar kindly confirm dia grade & length of DI pipe for rising main...

Refer addendum I; Sr. no.16

Queries/clarification raised by Enviro Infra Engineers Pvt.Ltd., New delhi

1 Vol.I / section II, cl. 4.3 page.1

The minimum eligibility criteria : We request that it should be modified to 25% of the capacity as asked in the tender as per the Govt of Rajasthan Rules. The same was also applicable in recent tenders of UIT KOTA and UIT Bikaner. Further please clarify whether the ETP/ CETP for qualification will be considered or not since the sewage is a type of effluent.

Bid conditions shall be adhered.

2 Vol.I / section II, cl. 4.3 page.1

The minimum eligibility criteria : We request that it should be modified to The Technology provided must have executed or executing CETP/ETP/STP of capacity not less than 4 MLD based on SBR technology in any Govt. Organization.

Bid conditions shall be adhered.

Page 23: CLARIFICATIONS FOR AJMER- PUSHKAR STP · CLARIFICATIONS FOR AJMER- PUSHKAR STP ... Treatment Plant at Anasagar Ajmer based on cyclic activated sludge Process/ SBR technology, ...

Clarification Contract Package JNNURM/AJM-PUSHK/WW/02

23 of 27

S. No. Reference Query

Reply of UIT, Ajmer

3 Vol.I / section v, Page 11

The Proposed STP at Pushkar is based on Anaerobic pond and Facultative pond. : The technology adopted for the proposed STP, as per tender documents is Anaerobic pond & Facultative pond. Using this technology. methane gas is generated which's directly liberated into atmosphere. Under the Kyoto Protocol signed by India it has been emphasized by all the nations to reduce the carbon emissions. Adopting this technology for the proposed STP may lead to extreme difficulties in environment clearances and even penalties may be imposed by the Govt. We suggest to go for any latest Technology for the STP i,e, SBR/FAB/UASB followed . by FAB deciding on the which is most economical in terms of Land Requirement/ Capital Cost/ Power Cost/ and Chemical Cost.

Bid conditions shall be adhered.

4 cl. 4.1, page 15

The size and Length of Pumping main at Ajmer and pushkar is not provided.: Please confirm the Size and Length of pumping main at Ajmer and Pushkar .

Refer Addendum I, Sr. no.16

5 Vol.I / section V,sub section II, Cl. 12.0 page -13

SBR Air Blower Cum Administrative Cum MCC & Control Building. The minimum Size Mentioned is 240 Sq. M with G+1 Structure : We request you to please review the size of this building.

Refer Addendum I, Sr. no.24

Page 24: CLARIFICATIONS FOR AJMER- PUSHKAR STP · CLARIFICATIONS FOR AJMER- PUSHKAR STP ... Treatment Plant at Anasagar Ajmer based on cyclic activated sludge Process/ SBR technology, ...

Clarification Contract Package JNNURM/AJM-PUSHK/WW/02

24 of 27

S. No. Reference Query

Reply of UIT, Ajmer

6 Vol.I / section V,sub section II, Cl. 12.0 page -14

No of Air Conditioners is not mentioned : Please specify the no. of Air Conditioner of the criteria for selecting the same : Please specify the no. of Air Conditioner or the criteria for selecting the same.

Refer addendum I Sr. no.25

7 General Preferred Make of Machinery & Equipments. : The makes may please be included as per the attached sheet.

Attached list is of preferred makes. However bidder may propose better makes, which may be accepted subject to approval of competent authority of department.

8 Vol.I / section I ,

Process Power Requirement : IN Schedule IX of section 10 there is no tables 1.2.3 and 4 for guaranteed power requirement Further in price bid it has not been clearly mentioned how the contractor quoting different Guaranteed Power requirement will be evaluated. We request that the same may be clearly specified and the loading for guaranteed power should be done as per UIT KOTA tender.

Refer addendum I, Sr. no.30 and clause 37.6 of section I , page 21, Vol.I.

9 Vol.I / section V,sub section VI 2.1 page 1

Specifies that UIT shall Provide one source of 11 KV 50c/S 3 Phase electrical power up to electrical meter within the premises and from this metering point onwards the successful bidder shall extend 11 KV supply to main sub station and further 433V (step down ) supply upto MCC room : Please clarify

Refer clause 80 of section IV, Vol.I, Page no. 46. Contractor shall apply for permanent power connection of STP and SPS. During construction contractor shall be solely responsible for power connection.

Page 25: CLARIFICATIONS FOR AJMER- PUSHKAR STP · CLARIFICATIONS FOR AJMER- PUSHKAR STP ... Treatment Plant at Anasagar Ajmer based on cyclic activated sludge Process/ SBR technology, ...

Clarification Contract Package JNNURM/AJM-PUSHK/WW/02

25 of 27

S. No. Reference Query

Reply of UIT, Ajmer

10 Vol.I / section V,sub section VI , Cl.2 page-14

Lists out items to be including in the scope of work. Contradicts clause 2.1 of page 1 and lists out items of 11 KV such as Four pole Structure with all accessories. 11 KV indoor CT/PT metering panel :

Refer Addendum I , Sr. no.26 and Clause 1.0 , scope of work, page 14 of sub section VI, section V, Vol. I.

11 Vol.I / section V,sub section VI , Cl.12.2 page -27

Specifies Thickness of CRCA Sheet Steel for fabrication of instrument Panel Cum Control Desk.

Bid conditions shall be adhered.

12 Vol.I / section V,sub section VI , Cl.44.1 page-18

Thickness of CRCA Sheet Steel for construction of Metal clad type 11 KV VCB Switchgear panel with Circuit Breaker & Associated Electrical Equipment is not specified : It is inform that fabrication Construction of control/Instrument Panels. Electrical/Lighting Switchboards/Panels is done out of 2/1.6 mm thick CRCA Sheet steel as a general practice by all manufactures and the same is accepted every where all over India. It is an acceptable thickness of CRCA/State PWDs/all Govt. Deptts and all public private Companies.

Bid conditions shall be adhered.

13 Vol.I / section V,sub section VI , Cl.6 page- 24

Thickness of cold Rolled Sheet Steel for Fabrication of Power Cum Motor Control Centre is specified as minimum 3 mm. :

Bid conditions shall be adhered.

Page 26: CLARIFICATIONS FOR AJMER- PUSHKAR STP · CLARIFICATIONS FOR AJMER- PUSHKAR STP ... Treatment Plant at Anasagar Ajmer based on cyclic activated sludge Process/ SBR technology, ...

Clarification Contract Package JNNURM/AJM-PUSHK/WW/02

26 of 27

S. No. Reference Query

Reply of UIT, Ajmer

14 Vol.I / section V,sub section VI , Cl.11 & 12 page-47 & 48

The requirement of minimum 3 mm thickness of sheet steel for Power Cum Motor Control Centre is specified.

Bid conditions shall be adhered.

15 Vol.I / section V,sub section VI , Cl.12.9 page 68

It is specified that Lighting Panel fabrication shall be out of minimum 2 mm thick Sheet Steel : It is requested that The thickness of CRCA Sheet Steel of 2/1.6 mm for all panels and Switchboards be allowed .

Bid conditions shall be adhered.

16 Vol.I / section V,sub section VI , Cl.15.4 page -76

It is specified that fabrication of Capacitor Control Panel Shall be out of 14G Sheet Steel which is 2 mm thickness.

Bid conditions shall be adhered.

17 Vol.I / section V,sub section VI , Cl.20 page-80

It is specified that construction Fabrication of Rotating Bridge Clarifier Control panel shall be out of minimum 3 mm thick cold rolled Sheet Steel.

Bid conditions shall be adhered.

Page 27: CLARIFICATIONS FOR AJMER- PUSHKAR STP · CLARIFICATIONS FOR AJMER- PUSHKAR STP ... Treatment Plant at Anasagar Ajmer based on cyclic activated sludge Process/ SBR technology, ...

Clarification Contract Package JNNURM/AJM-PUSHK/WW/02

27 of 27

S. No. Reference Query

Reply of UIT, Ajmer

18 Vol.I / section V,sub section VI , Cl.3 page-16

Under the heading "Specification of DG set" it is specified that DG Control Panel shall be of 16G (Which is 1.6mm thickness) Also it is specied that fabrication of Acoustic Enclosure of DG shall be out of 2mm CRCA Sheet Steel.

Bid conditions shall be adhered.

Queries/clarification raised by Girdhari Lal Aggarwal contractors Pvt Ltd., Haryana

1 General The NGL is about 1.2 meter below FSL of lake as per

DNIT therefore the SBR area has to be filled & compacted

to stand the Structure thrust & load. Please confirm.

Confirm

2 Vol. I,

Section VI

In DNIT the contour is provided with out specifying the

plotted area as proposed.

Refer other drawings enclosed with bid document.

3 General The quality or treated effluent as asked for in DNIT is just

impossible to achieve after SBR without tertiary treatment.

Please confirm

Bid conditions shall be adhered. Bidder can add any other unit or equipment to fulfill bid condition.

4 General Mobilisation advance shall be 15% against Bank Guarantee and deducted from the running bills.

Bid conditions shall be adhered.

Consultant (waste water) Assistant Engineer, Executive Engineer, PDCOR, Jaipur UIT, Ajmer UIT,Ajmer.