Claims taken from BLP’s website regarding CIHT
description
Transcript of Claims taken from BLP’s website regarding CIHT
![Page 1: Claims taken from BLP’s website regarding CIHT](https://reader035.fdocuments.in/reader035/viewer/2022070500/56816859550346895dde8783/html5/thumbnails/1.jpg)
Claims taken from BLP’s website regarding CIHT
This presentation takes snippets off of Blacklight Power’s website rgarding CIHT claims.Includes claims, data and independent validation reports.
Blacklight Power’s website is:http://www.blacklightpower.com
![Page 2: Claims taken from BLP’s website regarding CIHT](https://reader035.fdocuments.in/reader035/viewer/2022070500/56816859550346895dde8783/html5/thumbnails/2.jpg)
Claims taken from BLP’s website regarding CIHT
Regarding CIHT data shown in next two slides:
Energy input = 5 mA for 0.4 Seconds at an average of 0.79 Volts.Energy output = 5 mA for 4.1 Seconds at an average of 0.78 Volts
Power input = (Duty cycle)*(Volts)*(Current) = (0.4/4.5)*(0.005)*(0.79) = 0.351 mW Power Output = (Duty Cycle)*(Volts)*(Current) = (4.1/4.5)*(0.005)*(0.78) = 3.55 mW
Ratio = Output/Input = 3.55/0.351 = 11.2
Gain = (100%)*(Output/Input) = (100%)*(3.55/0.351)= 1120%
Output and input current could be measured using the exact same 1 ohm resistor (volts across resistor would be 0.005 V).Voltage across the cell remains fairly constant at 0.78 to 0.79 Volts.Total error for power measurements can easily be less than 3% with good equipment.
![Page 3: Claims taken from BLP’s website regarding CIHT](https://reader035.fdocuments.in/reader035/viewer/2022070500/56816859550346895dde8783/html5/thumbnails/3.jpg)
Claims taken from BLP’s website regarding CIHT
Curr
ent
Data taken from BLP’s report on CIHT results.
![Page 4: Claims taken from BLP’s website regarding CIHT](https://reader035.fdocuments.in/reader035/viewer/2022070500/56816859550346895dde8783/html5/thumbnails/4.jpg)
Claims taken from BLP’s website regarding CIHT
Volta
ge
Data taken from BLP’s report on CIHT results.
![Page 5: Claims taken from BLP’s website regarding CIHT](https://reader035.fdocuments.in/reader035/viewer/2022070500/56816859550346895dde8783/html5/thumbnails/5.jpg)
Claims taken from BLP’s website regarding CIHT
http://www.blacklightpower.com/technology/ciht-cell/
http://www.blacklightpower.com/faq/
10 W unit has been tested
![Page 6: Claims taken from BLP’s website regarding CIHT](https://reader035.fdocuments.in/reader035/viewer/2022070500/56816859550346895dde8783/html5/thumbnails/6.jpg)
Claims taken from BLP’s website regarding CIHT
Source:http://www.blacklightpower.com/business/business-summary
![Page 7: Claims taken from BLP’s website regarding CIHT](https://reader035.fdocuments.in/reader035/viewer/2022070500/56816859550346895dde8783/html5/thumbnails/7.jpg)
Claims taken from BLP’s website regarding CIHT
Source:http://www.blacklightpower.com/wp-content/uploads/presentations/businesspresentation-web.pdf
![Page 8: Claims taken from BLP’s website regarding CIHT](https://reader035.fdocuments.in/reader035/viewer/2022070500/56816859550346895dde8783/html5/thumbnails/8.jpg)
Claims taken from BLP’s website regarding CIHT
Source:http://www.blacklightpower.com/wp-content/uploads/presentations/businesspresentation-web.pdf
Output energy 2000 times the input
![Page 9: Claims taken from BLP’s website regarding CIHT](https://reader035.fdocuments.in/reader035/viewer/2022070500/56816859550346895dde8783/html5/thumbnails/9.jpg)
Claims taken from BLP’s website regarding CIHT
Source:http://www.blacklightpower.com/wp-content/uploads/presentations/businesspresentation-web.pdf
![Page 10: Claims taken from BLP’s website regarding CIHT](https://reader035.fdocuments.in/reader035/viewer/2022070500/56816859550346895dde8783/html5/thumbnails/10.jpg)
Claims taken from BLP’s website regarding CIHT
Source:http://www.blacklightpower.com/wp-content/uploads/presentations/businesspresentation-web.pdf
![Page 11: Claims taken from BLP’s website regarding CIHT](https://reader035.fdocuments.in/reader035/viewer/2022070500/56816859550346895dde8783/html5/thumbnails/11.jpg)
11
BLP CIHT results of energy output and gain.
5000% gain;Output is 50X input here.
10000%
1000%
10%
100%
source:http://blacklightpower.com/wp-content/uploads/presentations/TechnicalPresentation.pdf
For example, at 100% Energy Gain, output is equal to input.66 days
Energy Gain
![Page 12: Claims taken from BLP’s website regarding CIHT](https://reader035.fdocuments.in/reader035/viewer/2022070500/56816859550346895dde8783/html5/thumbnails/12.jpg)
Claims taken from BLP’s website regarding CIHT Source:http://www.blacklightpower.com/technology/validation-reports
6 teams/individuals from relevent industries wrote validation reports on CIHT
![Page 13: Claims taken from BLP’s website regarding CIHT](https://reader035.fdocuments.in/reader035/viewer/2022070500/56816859550346895dde8783/html5/thumbnails/13.jpg)
Claims taken from BLP’s website regarding CIHT
Source:http://www.blacklightpower.com/wp-content/uploads/pdf/WeinbergReport.pdf
![Page 14: Claims taken from BLP’s website regarding CIHT](https://reader035.fdocuments.in/reader035/viewer/2022070500/56816859550346895dde8783/html5/thumbnails/14.jpg)
Claims taken from BLP’s website regarding CIHT
Source:http://www.blacklightpower.com/wp-content/uploads/pdf/CopelandReport.pdf
5476% gain means that the output is 54 times larger than the input
![Page 15: Claims taken from BLP’s website regarding CIHT](https://reader035.fdocuments.in/reader035/viewer/2022070500/56816859550346895dde8783/html5/thumbnails/15.jpg)
Claims taken from BLP’s website regarding CIHT
Source:http://www.blacklightpower.com/wp-content/uploads/pdf/F500Study.pdf
200,000% gain means that the output is 2000 times larger than the input
![Page 16: Claims taken from BLP’s website regarding CIHT](https://reader035.fdocuments.in/reader035/viewer/2022070500/56816859550346895dde8783/html5/thumbnails/16.jpg)
Claims taken from BLP’s website regarding CIHT
242,132% gain means that the output is 2421 times larger than the input
286% gain means that the output is 2.8 times larger than the input
![Page 17: Claims taken from BLP’s website regarding CIHT](https://reader035.fdocuments.in/reader035/viewer/2022070500/56816859550346895dde8783/html5/thumbnails/17.jpg)
Claims taken from BLP’s website regarding CIHT
500% gain means that the output is 5 times larger than the input
![Page 18: Claims taken from BLP’s website regarding CIHT](https://reader035.fdocuments.in/reader035/viewer/2022070500/56816859550346895dde8783/html5/thumbnails/18.jpg)
Claims taken from BLP’s website regarding CIHT
Source:http://www.blacklightpower.com/wp-content/uploads/pdf/RamanujacharyReport.pdf
735% gain means that the output is 7.3 times larger than the input
![Page 19: Claims taken from BLP’s website regarding CIHT](https://reader035.fdocuments.in/reader035/viewer/2022070500/56816859550346895dde8783/html5/thumbnails/19.jpg)
Source:http://www.blacklightpower.com/wp-content/uploads/pdf/GlumacReport.pdf
2400 ratio of output to input !
Claims taken from BLP’s website regarding CIHT
![Page 20: Claims taken from BLP’s website regarding CIHT](https://reader035.fdocuments.in/reader035/viewer/2022070500/56816859550346895dde8783/html5/thumbnails/20.jpg)
Source:http://www.blacklightpower.com/wp-content/uploads/pdf/ENSERReport.pdf
144028% gain means that the output is 1440 times larger than the input
Claims taken from BLP’s website regarding CIHT