Cisa Serie 3600 - Menzlmenzl.com/download/cisa/Cisa_Sterilization_Units_Serie-3600.pdf · Cisa...

8
Cisa Serie 3600 Sterilization Units

Transcript of Cisa Serie 3600 - Menzlmenzl.com/download/cisa/Cisa_Sterilization_Units_Serie-3600.pdf · Cisa...

Cisa Serie • 3600

Sterilization Units

2

Sterilization Units

The efficacy of sterilization’s process is determining to eliminate the risks which comes through

the utilize of the medical dispositives on the human body.

For this reason Cisa has carried on a research and development program having the target to

realize a complete range of machines to meet all the kind of sterilization both in production terms

and application.

And every Cisa machine is designed and manufactured on the same principles: easy of use and

maintenance, safety, and reliability.

3600

3

All Cisa machines are designed for easy access and

maintenance.

Access is from the front, and the position of every component

is designed so as to make it to reach and service.

Technical assistance, ordinary maintenance and eventual

repairs are therefore quicker, simpler and more cost effective.

For each main component there is a maintenance programme

directly accessed through the touch screen.

The maintenance programmes also include the steam

generator, which automatically drains so as to eliminate water

contaminants or deposits.

Furthermore it is foreseen an interface to make the distant

maintenance.

Maintenance

The technology featured in every Cisa machine isn’t only

limited to the digital process control.

The Cisa research team has also dedicated a lot of effort to

the structure and construction of the machines.

A thorough choice of materials and components guarantee

the safety and durability of the machine under every

circumstance.

All Cisa machines are manufactured with the same

standards of hygiene and dependability, and feature,

amongst others, the following characteristics:

• Sterilization chamber, jacket and doors in stainless steel

chrome-nickel-molybdenum-titanium

• Design and type approval at 3,5 relative bar

• Frontal frame of the sterilization chamber in single piece

homogeneous with incorporated seat gasket and door

guides

• Mirror finish electrolytic polishing treatment

• Steam operated dynamic gasket, or in alternative

mechanical compression seal

• Pneumatic closure of the sterilization chamber with

automatic safety locking and vertical or horizontal sliding

door

• Pure self-lubricating silicone gaskets

• Non toxic fire resistant insulation foam, with extremely

low thermal conductivity and no release of particles

• Main supporting frame, front and internal panels in

stainless steel chrome-nickel-molybdenum

• Compact architecture, with overall dimensions always

restricted in relation to the machine capacity

• Effortless installation, with ease of positioning on the floor

and connection to the main utilities

Structure and Machine Design

4

All installed components are readily available on the market -

throughout the world.

Cisa has purposely chosen only components that are

manufactured by leading multinationals with worldwide

distribution networks and service centres.

The hydraulic plant is entirely made of stainless steel chrome-

nickel-molybdenum and insulated with silicone foam.

All electrics have a minimum protection requirement of IP 54.

Systems and Utilities

In the design of the Cisa range of machines, a lot of attention has been dedicated to

energy consumption.

This is why, for example, all insulating materials are top of the range, and with generous

thickness.

This ensures that operating costs are kept low.

Specific technical solutions have also brought the Cisa design team to implement

significant savings in water usage.

Each operating sterilizers which is not making any cycle, automatically it takes itself the

“stand-by” position, reducing considerably in this way the consumptions.

Energy Saving

5

Cisa sterilizers are designed with the most sophisticated safety

procedures in mind, that take into account the hazard and

risk analysis, the purpose of use, its specific class (IIa) and

the necessary protection for the operator, the product and the

environment.

Thus, for each component there is a back up spare ready to kick

in automatically in case of any problem with the first.

Moreover, the process control allows the reproduction of each

sterilization cycle in time.

Not only do all Cisa sterilization units undergo an electromagnetic

compatibility test.

They are also fitted with a network filter for electromagnetic

interference.

Safety

Each machine in the Cisa sterilization range is entirely managed by

programmable logic systems that allow for total cycle control, with a constant check on all

parameters and a verification of the safety of the process.

Two PLCs are interfaced with each other to ensure maximum safety of the process.

While one PLC manages the machine operation, the other (with separate

measurement systems) is in constant control, verifies and records the process.

This allows a constant and regular sterilization cycle, without the risk of

individual operator decisions.

An integrated printer automatically delivers a cycle report whose layout is designed both

graphically and in the wording to be easily read and interpreted.

A color touch screen monitor guides the operator through the various stages of the process,

with a user-friendly interface.

The machine can be supplied as a stand alone, or integrated in a global monitoring network

with remote control, or in a complete sterilization control system, which includes traceability.

Control System

6

Cisa’s prominent position on the market has allowed the company

to develop sufficient sales volumes to ensure, for each model of the

range, a production in series.

The repetition of all assembly operations and the industrialization of

the manufacturing process can therefore provide a very favourable

quality/cost ratio.

Industrialization

Cisa sterilization units conform to the requirements of the

European Standard EN 285 and to the different Standards it

refers to, amongst which are

EN 61010-1, EN 61010-2-041, EN 60204-1.

The machines are also CE marked according to the

CEE directive 93/42 for medical devices. Finally, they are validated according to EN 554.

The test approval of pressure vessels follows the requirements of the country of destination.

Quality and Safety Certificates

Cisa sterilizers can be automated to work optimally during their operative time.

In fact the turn on of the autoclave, the start of the heating cycle, of the vacuum

leakage test, of the Bowie & Dick test and its turn off, it may be effected

automatically by itself.

It is possible to automates also the material loading and unloading operations,

permitting to reduce the inactivity time of the machines.

Automation

Cisa sterilization machines are available in various

versions:

Steam units for solids or packaged porous

materials (“H”)

Combined steam and formaldehyde units

(“HF”)

Combined steam and liquid programme units

(“HL”)

Steam units for liquids, physiological solutions,

cultivation grounds, ampoules, vials and milk

treatment (“LS”)

Air-steam for high pathogenic materials and

virology (“LHP”)

Steam units for cages, food, liquids and stabularium

material (“LS”)

Versions

7

TECHNICAL DATA

DP

L -

360

0 -

01 -

GB

C

ISA

rese

rves

the

right

of m

odifi

catio

n w

ithou

t prio

r no

tice.

CISA S.p.A. Via Pontina Km 2800040 - Pomezia - Roma - Italia

Telefono +39 06 911437 1Fax +39 06 9107565

e-mail: [email protected]@cisagroup.it

[email protected]

Coordinamento Assistenza Tecnica+39 06 9122288

CISABRASILE LTDA.Rua Dona Francisca, 8300

Distrito Industrial - Bloco C- Módulo 6CEP 89239-270 - Joinville - SC Brasil

Telefone +55 47 3437-9090Fax +55 47 3435-7592

e-mail: [email protected]

CISA Middle East and CIS OfficeAlsafa Wa Almarwa Building,Almadina Almonawara StreetTelaa Al Ali, Amman Jordan

Phone +962 6 5516592Fax +962 6 5511596

e-mail: [email protected]. Box 3692 Amman 11821 - Jordan

CISA Latin America Office1840 Coral Way - Suite 101

Miami - FloridaZIP Code 33145

Phone 001-305-858-3406Fax 001-305-858-3451

e-mail: [email protected]

CISA Sub-Sahara OfficeLotissement El HamdLot 26 - Sidi Moumen

Casablanca - MoroccoPhone +212-22-74-11-45

Fax +212-22-74-10-42e-mail: [email protected]

CISA Asia Office190 Middle Road

# 19-05 Fortune CentreSingapore 188979

Phone +65 6826 1065Fax +65 6826 3373

e-mail: [email protected]

CISA India OfficeNew Delhi - India

e-mail: [email protected]