Circo LED - Steon Lightingsteon.com/wp-content/uploads/1970/01/circo-led-datasheet.pdf · Circo LED...

3
t: 01282 448666 f: 01282 417703 www.lampslighting.co.uk Circo LED Universal Surface Ceiling Luminaires Circo LED is a stylish, yet robust, IP65 low energy LED wall or ceiling luminaire suitable for interior or exterior use. It is available with an optional integrated Manual Intelligent Control (MIC) for enhanced energy savings. The Circo LED features an innovative integral lever for quick and easy lens removal. Circo LED is ideal for toilets, bathrooms, staircases, corridors, building facades and porches. Features: IP65 (dust tight & water jet proof) IK10 (20 joule) shock resistance Corrosion resistant Energy efficient Osram LEDs Low LED power consumption: 16W Optimum single bin LEDs with a 3 MacAdam ellipse tolerance High lumen output – superior illuminance to a 28W TC-DD compact fluorescent Average 50,000 hours LED life – maintenance free Wall or ceiling mounting Lever operated lens for quick / easy maintenance Removable gear tray 1 x 16 / 20mm conduit entry for side wiring Options: Available with an integrated microwave Manual Intelligent Control (MIC) – See pages 2&3 Integral 3hr maintained emergency LED available in two colour temperatures: – 3000K (warm) – 4000K (cool) 10W version available on request Material: Body: polycarbonate Lens: polycarbonate Finish: Trim: white, chrome or polished brass (available on special request) Lens: cloud Spares: All components are available from Lamps and Lighting’s UK manufacturing facility. The information given on these sheets is typical of the product depicted; it must not be interpreted as a guarantee of individual product performance and/or characteristics. We reserve the right to alter specifications and designs without prior notice. All measurements are in millimetres (mm). These luminaires are designed to comply with EN 60598-1 (BS 4533:101) Emergency EN 60598.2.22 (BS 4533:102.22) 330 140 180° 150° 150° 120° 120° 90° 90° 30° 30° 60° 60° cd / 1000 lm C0 / C180 C90 / C270 100 200 300 Circo LED 16W MIC System Available Chrome Trim Low energy efficiency High energy efficiency Ordering Example: LUC 103/WH/MIC3 LUC 1 03 /WH /MIC3 Circo LED Wattage LED Colour Temperature Finish Control E3-LUC 103/WH E3-LUC 104/WH E3-LUC 103/CH E3-LUC 104/CH White Trim LED 16W 3000K (warm) LED 16W 4000K (cool) Chrome Trim LED 16W 3000K (warm) LED 16W 4000K (cool) LUC 103/WH LUC 104/WH LUC 103/CH LUC 104/CH Standard Ordering Code Emergency MIC Compatibility (See pages 2&3) MIC 1 ü ü ü ü MIC 2 ü ü ü ü MIC 3 ü ü ü ü Circo LED Equivalent CFL Type 1 x 28W 1 x 28W 1 x 28W 1 x 28W

Transcript of Circo LED - Steon Lightingsteon.com/wp-content/uploads/1970/01/circo-led-datasheet.pdf · Circo LED...

t: 01282 448666f: 01282 417703

www.lampslighting.co.uk Circo LEDUniversal Surface Ceiling LuminairesCirco LED is a stylish, yet robust, IP65 low energy

LED wall or ceiling luminaire suitable for interior or exterior use. It is available with an optional integrated Manual Intelligent Control (MIC) for enhanced energy savings. The Circo LED features an innovative integral lever for quick and easy lens removal. Circo LED is ideal for toilets, bathrooms, staircases, corridors, building facades and porches.

Features:• IP65 (dust tight & water jet proof)• IK10 (20 joule) shock resistance• Corrosion resistant• Energy efficient Osram LEDs• Low LED power consumption: 16W • Optimum single bin LEDs with a 3 MacAdam ellipse tolerance• High lumen output – superior illuminance to a 28W TC-DD compact fluorescent • Average 50,000 hours LED life – maintenance free• Wall or ceiling mounting• Lever operated lens for quick / easy maintenance• Removable gear tray• 1 x 16 / 20mm conduit entry for side wiring

Options:• Available with an integrated microwave Manual Intelligent Control (MIC) – See pages 2&3• Integral 3hr maintained emergency• LED available in two colour temperatures: – 3000K (warm) – 4000K (cool)• 10W version available on request Material:• Body: polycarbonate• Lens: polycarbonate

Finish:• Trim: white, chrome or polished brass (available on special request)• Lens: cloud

Spares:All components are available from Lamps and Lighting’s UK manufacturing facility.

The information given on these sheets is typical of the product depicted; it must not be interpreted as a guarantee of individual product performance and/or characteristics.We reserve the right to alter specifications and designs without prior notice. All measurements are in millimetres (mm).

These luminaires are designed to comply with EN 60598-1 (BS 4533:101)Emergency EN 60598.2.22 (BS 4533:102.22)

330

140

180° 150°150°

120°120°

90°90°

0° 30°30°

60°60°

cd / 1000 lmC0 / C180 C90 / C270

100

200

300

Circo LED 16W MIC System Available

Chrome Trim

Low energy efficiency

High energy efficiency

Ordering Example:

LUC 103/WH/MIC3

LUC 1 03 /WH /MIC3

Circo LED Wattage LED Colour Temperature Finish Control

E3-LUC 103/WH

E3-LUC 104/WH

E3-LUC 103/CH

E3-LUC 104/CH

White Trim

LED 16W 3000K (warm)

LED 16W 4000K (cool)

Chrome Trim

LED 16W 3000K (warm)

LED 16W 4000K (cool)

LUC 103/WH

LUC 104/WH

LUC 103/CH

LUC 104/CH

Standard

Ordering Code

Emergency

MIC Compatibility (See pages 2&3)

MIC 1

ü

ü

ü

ü

MIC 2

ü

ü

ü

ü

MIC 3

ü

ü

ü

ü

Circo LED

Equivalent CFL Type

1 x 28W

1 x 28W

1 x 28W

1 x 28W

t: 01282 448666f: 01282 417703

www.lampslighting.co.uk MICThe Manual Intelligent Control (MIC) system features a range of advanced sensor technology controls offering the ultimate in energy saving and carbon reduction. Significant energy savings can be achieved with a MIC system that dynamically manages lamp power according to the instantaneous lighting requirement. It ensures that the right level of light appears at the right place only when required, this preventing unnecessary energy consumption and potentially reducing maintenance costs. The MIC system has been installed in over 3000 BT telephone exchanges with confirmed energy savings in excess of 70%.

There are three types of Manual Intelligent Control: MIC1, MIC2 and MIC3, available as a master (sensor incorporated) or a slave (controlled by master), to suit different requirements and budgets. The manual intelligent controls are programmed manually by a dip switch to switch on and off automatically to maximise cost savings.

MIC 1

MIC 2

MIC 3

MIC 1 is a versatile and cost-effective OFF–ON–OFF energy saving control unit.

MIC 2 offers all the benefits of the MIC 1 but with a DIM–ON–DIM function. MIC 2 is an ideal control for reducing energy consumptions whilst still providing some level of illumination for extra safety.

MIC 3 is the most flexible energy saving manual control with an OFF–ON–DIM–OFF function, permitting full light management and maximum energy saving.

OFF

DIM

OFF ON DIM OFF

ON

ON

OFF

DIM

Absence – luminaires areswitched off.

Absence – luminaires areon at a courtesy preset dimmed level. Approximately 20% output and 1/3 total power.

Absence – luminaires are switched off.

Occupancy detected – luminaires illuminate at full output.

After a preset time of absence, luminaires dim to the courtesy preset dimmed level. Approximately 20% output and 1/3 total power

After continued absence over a preset time, luminaires switch off completely. If required, the ‘off’ function can be disabled to operate as a MIC 2

Occupancy detected –luminaires illuminate at full output unless there is sufficient daylight and the lux level setting overides it.

Occupancy detected –luminaires illuminate at full output.

Absence – after a preset time, luminaires switch off completely.

Absence – after a preset time of absence, luminaires return to the courtesy preset dimmed level.

Suffix LuminaireOrdering Code

Suffix LuminaireOrdering Code

Suffix LuminaireOrdering Code

Master

/MIC1

Slave

/MIC1S

Example –Circo LED 4000K with whitetrim and intergrated MIC1 master system: LUC 104/WH/MIC1

Master

/MIC2

Slave

/MIC2S

Example –Circo LED 3000K with chrome trim and intergrated MIC2 slave system:LUC 103/CH/MIC2S

Master

/MIC3

Slave

/MIC3S

Example –Circo LED 4000K with white trim, emergency version and integrated MIC3 master system:E3-LUC 104/WH/MIC3

MIC 1

DIP Switch

0–2000 lux

N/A

5–30 mins

2–10 metres

N/A

360°

600W

Operating function

Lux level adjustment

Time adjustment to courtesy preset dimmed level

Time adjustment to switch off completely

Sensitivity (range) adjustment

Dimming level (iLite ballast/driver)

Detection angle

Sensor maximum load (inductive)

MIC 2

DIP Switch

N/A

5–30 mins

N/A

2–10 metres

10/25/50%

360°

600W

MIC 3

DIP Switch

N/A

5–30 mins

10–30 mins

1–6 metres

10/25/50%

360°

600W

MIC Operating Functions and Features

t: 01282 448666f: 01282 417703

www.lampslighting.co.uk MIC

Setting 1 =2metres Setting 2 = 5 metres Setting 3 =10metres

0

3.5

10 08 6 4 2 2 4 6 8 10

Detection area (metres)

Mou

ntin

g H

eigh

t (m

etre

s)

0

Sett ing 1 = 1 metre S ett ing 2 = 3 me tres S ett ing 3 = 6 me tres

0

8

10 08 6 4 2 2 4 6 8 10

Detection area (metres)

Mou

ntin

g H

eigh

t (m

etre

s)

0

Master Master Master Master

Master Master Master Master

Master Master Master Master

Master Slave Master Slave

Master Slave Master Slave

Master Master Master Master

Master Master Master Master

Master Master Master Master

Master Slave Master Slave

Master Slave Master Slave

OnKey: Off

Typical Installation Options

The MIC system offers complete flexibility as it can be easily installed into existing or new lighting schemes and requires no complex programming. The following wiring options are available:

Option One

The masters are all working independently for maximum energy efficiency to create a cascade effect. This is ideal for a retrofit installation.

Option Two

The master is working in conjunction with a slave to illuminate a specific zone. The master will control the slaves.

Option Three

The masters and the slaves are working in conjunction to illuminate a larger area.

Option Four

The masters are working together for maximum energy efficiency and sensitivity in a zoned area.

Option Five

All masters are working together for maximum sensitivity and control of a complete area.

Detection Area

MIC 1 & 2 MIC 3