CINEMA SOUND ISOLATION

23
David Schwind Tom Schindler Charles M Salter Associates Inc San Francisco, CA, USA CINEMA SOUND ISOLATION Consultants in Acoustics & Audio/Visual System Design

Transcript of CINEMA SOUND ISOLATION

Page 1: CINEMA SOUND ISOLATION

David SchwindTom Schindler

Charles M Salter Associates IncSan Francisco, CA, USA

CINEMASOUND

ISOLATION

Consultants in Acoustics & Audio/Visual System Design

Page 2: CINEMA SOUND ISOLATION

NEW ISSUES FACING DEVELOPERS

NOISIER SITES NEXT TO RAILWAY TRACKS, FREEWAYS, AND AIRPORTS

INCLUSION IN MIXED-USE RESIDENTIAL AND RETAIL BUILDINGS

Page 3: CINEMA SOUND ISOLATION

CINEMA AS A NOISE RECEIVER

ON-SITE NOISE (AND VIBRATION) MEASUREMENTS

RAILWAY-AIRBORNE NOISE, GROUND VIBRATION-ISOLATE CINEMAS WITH RUBBER BEARINGS

ROADS-WALLS AND DOORS TYPICALLY DOMINATE

AIRPORTS-CEILING, WALLS, AND DOORS DOMINATE

Page 4: CINEMA SOUND ISOLATION

CINEMA AS A SOUND SOURCEFOR RESIDENCES

DO NOT LOCATE DIRECTLY ADJACENT TO RESIDENCES

ACOUSTICAL OBJECTIVE TO PREVENT SLEEP INTERFERENCE

Page 5: CINEMA SOUND ISOLATION

THE ROLE OF SOUND ISOLATION IN THE CINEMA PRESENTATION

SUSPENSION OF DISBELIEF-HOLDING THE PATRON IN THE FILM STORY

MAINTAINS THE POTENTIAL FOR THE NOW EXCELLENT DYNAMIC RANGE OFCINEMA AUDIO SYSTEMS-BOTH TOP AND BOTTOM OF RANGE

CRUCIAL TO THE SUCCESSFULIMPLEMENTATION OF MULTI-CINEMA

Page 6: CINEMA SOUND ISOLATION

INTRUSIVE SOUND SOURCESIMPACTING CINEMAS

EXTERIOR/EXTERNAL NOISE-TRAFFIC, AIRCRAFT, ETC.-ADJACENT TENANTS

PATRONS IN ENTRY LOBBIES,FOYER SOUND SYSTEMS, ELEVATORS,AND ADJACENT CONCESSION AREAS

SOUND SYSTEMS IN ADJACENT CINEMAS

Page 7: CINEMA SOUND ISOLATION

SOUND TRANSMISSION

INCIDENT

REFLECTED

TRANSMITTED

DIS

SIPA

TED

SOURCE BARRIER RECEIVER

DIS

SIPA

TED

Page 8: CINEMA SOUND ISOLATION

HORIZONTALSOUND

ISOLATION

Page 9: CINEMA SOUND ISOLATION

FIBERGLASS BATT INSULAT ION

(3) LAYERS 15 mm (5/8”)GYPSUM BOARD

(2) LAYERS 15 mm (5/8”) GYPSUM BOARD ON RES ILEINT

146 mm (6”) M ETAL STUD , 600 mm (24”) O .C .

(9 -5/8”)

SINGLE FRAME/RESILIENT CHANNEL DEMISING WALL

240 mm

Page 10: CINEMA SOUND ISOLATION

DOUBLE FRAME DEMISING WALL

BATT INSULAT ION

(1) LAYER 19 mm (3/4") and

(2) LAYERS 12 .5 mm (1/2")

GYPSUM BOARD ON EACH

OUTSIDE STUD FACE

146 mm (6") METAL STUD , 600 mm (24") O .C .

550 mm(22")

Page 11: CINEMA SOUND ISOLATION

BLOCK/FRAME DEMISING WALL

50 mm (2") SEPARAT ION , M IN IMUM

190 mm (8") SOLID CORE OR SOLID

GROUTED MASONRY

(2) 12 .5 mm (1/2") GYPSUM BOARD

BATT INSULAT ION

146 mm (6") METAL STUD , 600 mm (24") O .C .

(1) 12 .5 mm (1/2") GYPSUM BOARD

480 mm

(19")

Page 12: CINEMA SOUND ISOLATION

DEMISING WALLS/THX RECOMMENDATION COMPARISON

-10

0

10

20

30

40

50

60

70

80

90

100

31.5 63 125 250 500 1K 2K 4K 8KOCTAVE BAND CENTER FREQUENCIES - HERTZ

SOUND P

RESS

URE

LEV

EL/T

RANSM

ISSI

ON L

OSS

-DEC

IBEL

S

BLOCK/FRAME WALLTRANSMISSION LOSS

DOUBLE FRAME WALLTRANSMISSION LOSS

SINGLE FRAME WALLTRANSMISSION LOSS

SINGLE STUDRESILIENT CHANNNEL

DOUBLE FRAME

BLOCK/FRAME

Page 13: CINEMA SOUND ISOLATION

SINGLE STUDRESILIENT CHANNNEL

DOUBLE FRAME

BLOCK/FRAME

DEMISING WALL FIELD ISOLATION PERFORMANCE-RESULTS ONLY

-10

0

10

20

30

40

50

60

70

80

90

100

31.5 63 125 250 500 1K 2K 4K 8KOCTAVE BAND CENTER FREQUENCIES - HERTZ

SOUND P

RESS

URE

LEV

EL/T

RANSM

ISSI

ON L

OSS

-DEC

IBEL

S

NC 40

NC 35

NC 30

NC 25

NC 20

NC 15

BLOCK/FRAME-RESULTING INTRUSIVESOUND LEVEL (BLOCK)

DOUBLE FRAME-RESULTING INTRUSIVESOUND LEVEL

SINGLE FRAME-RESULTING INTRUSIVESOUND LEVEL

Page 14: CINEMA SOUND ISOLATION

DISCONTINUOUS ROOF SYSTEMAT DEMISING WALL

Page 15: CINEMA SOUND ISOLATION

VERTICALSOUND

ISOLATION

Page 16: CINEMA SOUND ISOLATION

FIN ISH CEIL ING

(NRC-0 .60)

CONCRETE FLOOR DECK WITH

ACOUSTICAL TILE CEILING

150 mm (6”) F IBERGLASSBATT INSULAT ION

CONCRETEDECK

150 mm (6”)

Page 17: CINEMA SOUND ISOLATION

CONCRETE FLOOR DECK WITH RESILIENTLY SUSPENDED

CEILING

CONCRETEDECK

ISOLATOR

6" BATT

15 mm (5/8”) GYPSUM BOARD

FIN ISH CEIL ING

(NRC-0 .60)

INSULAT ION

15mm (5/8”) PLYW OOD

150 mm (6”)

Page 18: CINEMA SOUND ISOLATION

100mm (4”) REINFORCED 2400 kg/m 3 (150 lb/ft3)CONCRETE

15 mm (5/8”) PLYW OOD

50 mm (2”) RES IL IENTSYSTEM

STRUCTURAL DECK*

TYPICALLY - 50 mm (2”) TALL ISOLATORS600 mm (24”) O .C . SURROUNDED W ITH

16 kg/m 3 (1 lb/ft3) F IBERGLASS BATT INSULATION

*

(150 mm (6”) CONCRETE)

CONCRETE FLOATING FLOOR

Page 19: CINEMA SOUND ISOLATION

CONCRETE FLOATING FLOORWITH STADIUM SEATING

19 mm (3/4”) NEOPRENE PAD

100mm (4”) REINFORCED 2400 kg/m 3 (150 lb/ft3)CONCRETE

15 mm (5/8”) PLYW OOD

50 mm (2”) RES IL IENTSYSTEM

STRUCTURAL DECK(150 mm (6”) CONCRETE)

Page 20: CINEMA SOUND ISOLATION

CINEMA FLOOR/CEILING PERFORMANCE

-10

0

10

20

30

40

50

60

70

80

90

100

31.5 63 125 250 500 1K 2K 4K 8KOCTAVE BAND CENTER FREQUENCIES - HERTZ

SOU

ND

PRE

SSU

RE L

EVEL

/TRA

NSM

ISSI

ON

LO

SS-D

ECIB

ELS

NC 40

NC 35

NC 30

NC 25

NC 20

NC 15

150 mm (6”) CONCRETE SLAB WITHACOUSTICAL CEILINGTRANSMISSION LOSS

150 mm (6”) THICK SLABWITH GYPSUM BOARD CEILING-

TRANSMISSION LOSS

100 mm (4 “) THICK FLOATING SLAB OVER STRUCTURAL SLAB

TRANSMISSION LOSS

CONCRETE FLOOR DECK WITH ACOUSTICAL TILE CEILING

CONCRETE FLOOR DECK WITH RESILIENT CEILING

CONCRETE FLOATING FLOOR

Page 21: CINEMA SOUND ISOLATION

CINEMA FLOOR/CEILING PERFORMANCE

-10

0

10

20

30

40

50

60

70

80

90

100

31.5 63 125 250 500 1K 2K 4K 8KOCTAVE BAND CENTER FREQUENCIES - HERTZ

SOU

ND

PRE

SSU

RE L

EVEL

/TRA

NSM

ISSI

ON

LO

SS-D

ECIB

ELS

NC 40

NC 35

NC 30

NC 25

NC 20

NC 15

CONCRETE FLOOR DECK WITH ACOUSTICAL TILE CEILING

CONCRETE FLOOR DECK WITH RESILIENT CEILING

CONCRETE FLOATING FLOOR

RESULTING INTRUSIVESOUND LEVEL (SLAB W/

RESILIENT CEILING)

RESULTING INTRUSIVE SOUNDLEVEL (FLOATING FLOOR)

RESULTING INTRUSIVE SOUND LEVEL (SLAB W/ ACT CEILING)

Page 22: CINEMA SOUND ISOLATION

SUMMARY

MEASURE SOUND LEVELS ON NOISY SITES

DEFINE THE ACOUSTICAL CRITERIA

SELECT INTER-CINEMA DOUBLE WALLS

DON’T NEGLECT VERTICAL ISOLATION

DON’T LOCATE CINEMAS DIRECTLY ADJACENT RESIDENCES

Page 23: CINEMA SOUND ISOLATION

Charles M Salter Associates Inc

Consultants in Acoustics & Audio/Visual System Design

CINEMASOUND

ISOLATION