CHROMATOGRAPHY
![Page 2: Chromatography new](https://reader033.fdocuments.in/reader033/viewer/2022061103/53fecaa48d7f726a5c8b46b0/html5/thumbnails/2.jpg)
CHROMATOGRAPHY
A laboratory technique in which the components of a sample are separated based on how they distribute between two chemical or physical phases, one of which is stationary and other of which is allowed to travel through the separation system.
![Page 3: Chromatography new](https://reader033.fdocuments.in/reader033/viewer/2022061103/53fecaa48d7f726a5c8b46b0/html5/thumbnails/3.jpg)
CHROMATOGRAPHY
Introduced first by the Russian botanist Mikhail Semenovich Tswett.
Mixtures of solutes dissolved in a common solvent are separated from one another by a differential distribution of the solutes between two phases.
![Page 4: Chromatography new](https://reader033.fdocuments.in/reader033/viewer/2022061103/53fecaa48d7f726a5c8b46b0/html5/thumbnails/4.jpg)
PRINCIPLE
Fractionalism of mixtures of substances
In the operation of the chromatogram, a mobile gaseous or liquid phase is use to wash the substances to be separated through a column of a porous material.
![Page 5: Chromatography new](https://reader033.fdocuments.in/reader033/viewer/2022061103/53fecaa48d7f726a5c8b46b0/html5/thumbnails/5.jpg)
PRINCIPLE
The rate of migration of the solute depends upon the rate of interaction of the solute with the two phases, one being the mobile phases and the other stationary phase as the compounds travel through the supporting medium.
![Page 6: Chromatography new](https://reader033.fdocuments.in/reader033/viewer/2022061103/53fecaa48d7f726a5c8b46b0/html5/thumbnails/6.jpg)
DEFINITION OF TERMS:
Capillary Action – the movement of liquid within the spaces of a material due to the forces of adhesion, cohesion, and surface tension.
Retention time Peak Viscosity
![Page 7: Chromatography new](https://reader033.fdocuments.in/reader033/viewer/2022061103/53fecaa48d7f726a5c8b46b0/html5/thumbnails/7.jpg)
DEFINITION OF TERMS:
VOCs Stationary phase Mobile phase
![Page 8: Chromatography new](https://reader033.fdocuments.in/reader033/viewer/2022061103/53fecaa48d7f726a5c8b46b0/html5/thumbnails/8.jpg)
COMPONENTS OF A CHROMATOGRAPH
MOBILE PHASE – A phase that is flowing through the column and causes sample components to move toward the column’s end.
STATIONARY PHASE- A fixed phase that is coated or bonded within the column; it always remain in the system.
It is responsible for delaying the movement of compounds as they travel through the column.
SUPPORT- onto which the SP is coated or attached.
![Page 9: Chromatography new](https://reader033.fdocuments.in/reader033/viewer/2022061103/53fecaa48d7f726a5c8b46b0/html5/thumbnails/9.jpg)
COMPONENTS OF A CHROMATOGRAPH
Receiving vessel
COLUMNORIGINAL SAMPLE AND MOBILE PHASE
SUPPORT AND STATIONARY PHASE
![Page 10: Chromatography new](https://reader033.fdocuments.in/reader033/viewer/2022061103/53fecaa48d7f726a5c8b46b0/html5/thumbnails/10.jpg)
TYPES OF CHROMATOGRAPHY
CAN BE CLASSIFIED ACCORDING TO:
∞MOBILE PHASE∞STATIONARY PHASE∞SUPPORT
![Page 11: Chromatography new](https://reader033.fdocuments.in/reader033/viewer/2022061103/53fecaa48d7f726a5c8b46b0/html5/thumbnails/11.jpg)
GAS CHROMATOGRAPHY
A type of Chromatography in which the mobile phase is a GAS.
First GC system was developed by Erika Cremer
The presence of a gas mobile phase makes GC valuable for separating substances like VOCs that occur naturally as gases that can easily be placed into gaseous phase.
![Page 12: Chromatography new](https://reader033.fdocuments.in/reader033/viewer/2022061103/53fecaa48d7f726a5c8b46b0/html5/thumbnails/12.jpg)
GAS CHROMATOGRAPHY
• It can separate nanograms or pictograms of volatile substances.
• It is principally a method for the separation and quantitative determination of gases and volatile liquids and substances.
![Page 13: Chromatography new](https://reader033.fdocuments.in/reader033/viewer/2022061103/53fecaa48d7f726a5c8b46b0/html5/thumbnails/13.jpg)
GAS CHROMATOGRAPHY
HOW IS IT PERFORMED? A System called Gas Chromatograph
is used to perform GC.COMPONENTS:
GAS SOURCEINJECTION SYSTEMCOLUMNDETECTOR
![Page 14: Chromatography new](https://reader033.fdocuments.in/reader033/viewer/2022061103/53fecaa48d7f726a5c8b46b0/html5/thumbnails/14.jpg)
![Page 15: Chromatography new](https://reader033.fdocuments.in/reader033/viewer/2022061103/53fecaa48d7f726a5c8b46b0/html5/thumbnails/15.jpg)
GAS CHROMATOGRAPHY∞GAS SOURCE- supplies the mobile
phase. It is typically a gas cylinder equipped with pressure regulators to deliver the mobile phase at a controlled state.
∞ INJECTION SYSTEM- consists of a heated loop or port into which the sample is placed and converted into a gaseous form.
![Page 16: Chromatography new](https://reader033.fdocuments.in/reader033/viewer/2022061103/53fecaa48d7f726a5c8b46b0/html5/thumbnails/16.jpg)
GAS CHROMATOGRAPHY∞COLUMN- contains the stationary
phase and support material for the separation of components in the sample. This column is held in an enclosed area known as the column oven.
∞COLUMN OVEN- maintains the temperature at a well-defined value.
∞DETECTOR- monitors sample components as they leave the column.
![Page 17: Chromatography new](https://reader033.fdocuments.in/reader033/viewer/2022061103/53fecaa48d7f726a5c8b46b0/html5/thumbnails/17.jpg)
GAS CHROMATOGRAPHYFACTORS THAT AFFECT GC:
Requirements for the AnalyteVolatility and Thermal StabilityChemical Derivatization
![Page 18: Chromatography new](https://reader033.fdocuments.in/reader033/viewer/2022061103/53fecaa48d7f726a5c8b46b0/html5/thumbnails/18.jpg)
GAS CHROMATOGRAPHYCommon Mobile Phases in GC: Hydrogen Helium Nitrogen Argon
![Page 19: Chromatography new](https://reader033.fdocuments.in/reader033/viewer/2022061103/53fecaa48d7f726a5c8b46b0/html5/thumbnails/19.jpg)
GAS CHROMATOGRAPHYGC SUPPORT MATERIALS
Packed Columnfilled with small support particles that
acts as an adsorbent or that are coated with the desired stationary phase.
Open- Tubular Columnsstationary phase coated on or attached
to its interior surface.
![Page 20: Chromatography new](https://reader033.fdocuments.in/reader033/viewer/2022061103/53fecaa48d7f726a5c8b46b0/html5/thumbnails/20.jpg)
GAS CHROMATOGRAPHYGC STATIONARY PHASES
Gas- Solid Chromatography ( solid adsorbents)
Gas-Liquid Chromatography (liquids coated on solids)
Bonded phases
![Page 21: Chromatography new](https://reader033.fdocuments.in/reader033/viewer/2022061103/53fecaa48d7f726a5c8b46b0/html5/thumbnails/21.jpg)
GAS CHROMATOGRAPHY◊ Gas-Solid Chromatography
o Solid adsorbent is used as a stationary phase.o Uses the same material as both the support
and stationary phase, with retention occurring through the adsorption of analytes to the support’s surface.
o Example of support is a MOLECULAR SIEVE.o Other supports include:
oORGANIC POLYMERS - porous polystyreneo INORGANIC SUBSTANCES – Silica or
Alumina
![Page 22: Chromatography new](https://reader033.fdocuments.in/reader033/viewer/2022061103/53fecaa48d7f726a5c8b46b0/html5/thumbnails/22.jpg)
GAS CHROMATOGRAPHY
o Increasing the surface area of the GSC support will increase the phase ratio and result in higher retention for analytes
o Pore size is important because only compounds smaller than the pores are able to contact the surface are within the space.
o Polarity of Support and its functional groups will also affect how analytes will bind to them.
![Page 23: Chromatography new](https://reader033.fdocuments.in/reader033/viewer/2022061103/53fecaa48d7f726a5c8b46b0/html5/thumbnails/23.jpg)
GAS CHROMATOGRAPHY◊ Gas-Liquid Chromatography
o A chemical coating or layer is placed onto the support and used as the stationary phase.
o Most Common types of GC.
o 100% dimethylpolysiloxane, 5%phenyl-95% methyl polysiloxane – Examples of liquids that are used as Stationary phase.
![Page 24: Chromatography new](https://reader033.fdocuments.in/reader033/viewer/2022061103/53fecaa48d7f726a5c8b46b0/html5/thumbnails/24.jpg)
GAS CHROMATOGRAPHY◊ Gas-Liquid Chromatography
o All of these liquids have High boiling points and low volatilities, which allows them to stay within the column at relatively high temperatures that are often used in GC for sample injection and elution.
o Liquids are also wettable- easy to place onto a support in a thin, uniform layer.
![Page 25: Chromatography new](https://reader033.fdocuments.in/reader033/viewer/2022061103/53fecaa48d7f726a5c8b46b0/html5/thumbnails/25.jpg)
GAS CHROMATOGRAPHY◊ Gas-Liquid Chromatography
o All of these liquids have High boiling points and low volatilities, which allows them to stay within the column at relatively high temperatures that are often used in GC for sample injection and elution.
o Liquids are also wettable- easy to place onto a support in a thin, uniform layer.
![Page 26: Chromatography new](https://reader033.fdocuments.in/reader033/viewer/2022061103/53fecaa48d7f726a5c8b46b0/html5/thumbnails/26.jpg)
GAS CHROMATOGRAPHY◊ Bonded Phases
o Column Bleed- most nonvolatile liquid will slowly vaporize or break apart and leave the column over time.
o Column bleed changes the retention characteristics of the column.
o It can also cause some GC detectors to have a high background and noisy signal as the stationary phase leaves the column and enters the detector.
o Use of bonded phase minimize column bleed.
![Page 27: Chromatography new](https://reader033.fdocuments.in/reader033/viewer/2022061103/53fecaa48d7f726a5c8b46b0/html5/thumbnails/27.jpg)
GAS CHROMATOGRAPHY◊ Bonded Phases
o Produced by reacting groups on a polysiloxane stationary phase with silanol groups that are located on the surface of a silica support.
![Page 28: Chromatography new](https://reader033.fdocuments.in/reader033/viewer/2022061103/53fecaa48d7f726a5c8b46b0/html5/thumbnails/28.jpg)
GAS CHROMATOGRAPHYTypes of Gas Chromatography Detectors General Detectors
x Thermal Conductivity Detector-used for both organic and inorganic
compounds-measures the ability of the eluting
carrier gas and analyte mixture to conduct heat away from hot-wire filament-”thermal conductivity”.-example: Wheatstone bridge
![Page 29: Chromatography new](https://reader033.fdocuments.in/reader033/viewer/2022061103/53fecaa48d7f726a5c8b46b0/html5/thumbnails/29.jpg)
GAS CHROMATOGRAPHY Flame Ionization Detector
- detects organic compounds by measuring their ability to produce ions when they are burned in flame.
![Page 30: Chromatography new](https://reader033.fdocuments.in/reader033/viewer/2022061103/53fecaa48d7f726a5c8b46b0/html5/thumbnails/30.jpg)
GAS CHROMATOGRAPHY Selective Detectors
x Nitrogen-Phosphorous Detector - selective for the determination of nitrogen- or phosphorous containing compounds. - Similar to FID, but does not use a flame for ion production.
![Page 31: Chromatography new](https://reader033.fdocuments.in/reader033/viewer/2022061103/53fecaa48d7f726a5c8b46b0/html5/thumbnails/31.jpg)
GAS CHROMATOGRAPHY Electron capture detector
- detects compounds that have electronegative atoms or groups in their structure, such as halogen atoms ( I,Br,Cl and F) and Nitro Groups.
-can also be used to detect polynuclear aromatic compounds, anhydrides and conjugated carbonyl compounds.
![Page 32: Chromatography new](https://reader033.fdocuments.in/reader033/viewer/2022061103/53fecaa48d7f726a5c8b46b0/html5/thumbnails/32.jpg)
GAS CHROMATOGRAPHYApplications: Most effectively used for analyses of
organic compounds, space related, complex mixtures of volatile substances at column temperature of less than -40 °C to greater than 550° C.
Geochemical research projects such as determination of various environmental pollutants at extremely low concentrations.
![Page 33: Chromatography new](https://reader033.fdocuments.in/reader033/viewer/2022061103/53fecaa48d7f726a5c8b46b0/html5/thumbnails/33.jpg)
GAS CHROMATOGRAPHY
ADVANTAGES:o Ability to provide
qualitative information and quantitative information
o FAST ANALYSISo Efficient, providing high
resolutiono Sensitiveo Nondestructiveo Requires small sampleso Inexpensive
DISADVANTAGES:o LIMITED to volatile
sampleso Not suitable for
thermally labile samples
o Fairly difficult for large preparative samples
o Requires spectroscopy usually mass spectroscopy for confirmation of peak identity
![Page 34: Chromatography new](https://reader033.fdocuments.in/reader033/viewer/2022061103/53fecaa48d7f726a5c8b46b0/html5/thumbnails/34.jpg)
LIQUID CHROMATOGRAPHY√ A Chromatographic technique in which
the mobile phase is a liquid.√ Originally developed by Russian
botanist Mikhail Tswett in 1903.√ Its popularity is due to the ability of this
method to work directly with liquid samples, which makes it valuable in such areas as food testing, environmental testing and biotechnology.
![Page 35: Chromatography new](https://reader033.fdocuments.in/reader033/viewer/2022061103/53fecaa48d7f726a5c8b46b0/html5/thumbnails/35.jpg)
LIQUID CHROMATOGRAPHYHOW IS LIQUID CHROMATOGRAPHY
PERFORMED? A System known as a Liquid
Chromatograph is used to perform LC.
![Page 36: Chromatography new](https://reader033.fdocuments.in/reader033/viewer/2022061103/53fecaa48d7f726a5c8b46b0/html5/thumbnails/36.jpg)
LIQUID CHROMATOGRAPHY√ Components of the LC System:
Support – enclosed in a Column Stationary phase- enclosed in a Column Liquid mobile phase-delivered to Column by
means of Pump Injection device- on analytical applications it
is being used,to apply samples to the column.
Collection Device (optional)- placed after the column to capture analytes as they elute.
![Page 37: Chromatography new](https://reader033.fdocuments.in/reader033/viewer/2022061103/53fecaa48d7f726a5c8b46b0/html5/thumbnails/37.jpg)
![Page 38: Chromatography new](https://reader033.fdocuments.in/reader033/viewer/2022061103/53fecaa48d7f726a5c8b46b0/html5/thumbnails/38.jpg)
LIQUID CHROMATOGRAPHYFACTORS THAT AFFECT LIQUID CHROMATOGRAPHY:
*requires both a difference in retention and good efficiency for it to separate two given chemicals*Sample*Analyte Requirements*Formats*Role played by the Mobile phase
![Page 39: Chromatography new](https://reader033.fdocuments.in/reader033/viewer/2022061103/53fecaa48d7f726a5c8b46b0/html5/thumbnails/39.jpg)
LIQUID CHROMATOGRAPHYRequirements for the Analyte:Must be possible to place this
chemical into a liquid that can be injected onto the column.
There must be a difference in retention between the analytes to be prepared.
![Page 40: Chromatography new](https://reader033.fdocuments.in/reader033/viewer/2022061103/53fecaa48d7f726a5c8b46b0/html5/thumbnails/40.jpg)
LIQUID CHROMATOGRAPHYTypes of Liquid Chromatography: Adsorption Chromatography Partition Chromatography Ion-Exchange Chromatography Size-Exclusion Chromatography Affinity Chromatography
![Page 41: Chromatography new](https://reader033.fdocuments.in/reader033/viewer/2022061103/53fecaa48d7f726a5c8b46b0/html5/thumbnails/41.jpg)
LIQUID CHROMATOGRAPHY1. ADSORPTION CHROMATOGRAPHY
A chromatographic technique that separates solutes based on their adsorption to the surface of a support. Also known as Liquid-Solid Chromatography Equivalent method in GC is Gas-Solid
Chromatography Uses the same material as both stationary
phase and support. Retention process can be explained on the ff
below: A+ n M-Surface A-Surface + n M
![Page 42: Chromatography new](https://reader033.fdocuments.in/reader033/viewer/2022061103/53fecaa48d7f726a5c8b46b0/html5/thumbnails/42.jpg)
LIQUID CHROMATOGRAPHY Elutropic strength- strength of a
mobile phase in adsorption chromatography It is a measure of how strongly a
particular solvent or liquid mixture will absorb to the surface of a given support.
Examples: silica and Alumina supports A liquid with large elutropic strength will
strongly adsorb to the given support, which will prevent the analyte from binding to the support.
![Page 43: Chromatography new](https://reader033.fdocuments.in/reader033/viewer/2022061103/53fecaa48d7f726a5c8b46b0/html5/thumbnails/43.jpg)
LIQUID CHROMATOGRAPHY
![Page 44: Chromatography new](https://reader033.fdocuments.in/reader033/viewer/2022061103/53fecaa48d7f726a5c8b46b0/html5/thumbnails/44.jpg)
LIQUID CHROMATOGRAPHY
![Page 45: Chromatography new](https://reader033.fdocuments.in/reader033/viewer/2022061103/53fecaa48d7f726a5c8b46b0/html5/thumbnails/45.jpg)
LIQUID CHROMATOGRAPHY2. PARTITION CHROMATOGRAPHYo It is a Liquid Chromatographic
technique in which solutes are separated based on their partitioning between a liquid mobile phase and a stationary phase coated on a solid support.
o Support used is usually Silicao Originally, it involves coating of support
with a liquid stationary phase that was immiscible with the mobile phase
![Page 46: Chromatography new](https://reader033.fdocuments.in/reader033/viewer/2022061103/53fecaa48d7f726a5c8b46b0/html5/thumbnails/46.jpg)
LIQUID CHROMATOGRAPHYTwo Main Categories of Partition Chromatography:• Normal-phase- uses polar stationary
phase
• Reversed phase-uses nonpolar stationary phase
![Page 47: Chromatography new](https://reader033.fdocuments.in/reader033/viewer/2022061103/53fecaa48d7f726a5c8b46b0/html5/thumbnails/47.jpg)
LIQUID CHROMATOGRAPHYApplications: Used in analytical laboratories Use of NPLC for separating analytes in
organic solvents and chemicals that contain polar functional groups.
![Page 48: Chromatography new](https://reader033.fdocuments.in/reader033/viewer/2022061103/53fecaa48d7f726a5c8b46b0/html5/thumbnails/48.jpg)
LIQUID CHROMATOGRAPHY3. ION- EXCHANGE CHROMATOGRAPHYSolutes are separated by their adsorption onto a support containing fixed charges on its surface. Routinely used in Industry for the
removal or replacement of Ions in products.
Used for the separation of charged compounds
( inorg. Ions, org. ions, AA, Proteins and Nucleic Acids)